1
Photoelectric Sensors
Examples of Applications
Compact Dimensions
Long Distance Sensing
Detection of boxes on conveyor belts Detection of plastic bottles
Models detect objects as far as 25 meters away.
Reduction of up to 40% in energy consumptionwhen compared to other series
Detection of plastic bottle caps
12 mm
31.8 mm
20 mm
25,4 mmou 1"
1" Standard mounting holesOR3KF-CXP-PN
GreenPower
Run Mode
YellowOutput
BlueMagneticButtom
CXP Line
A magnetic key is all that is needed to configurethe sensor.After a few steps the , the sensor is ready for use.
Increased Sensing DistânceThru-Beam models with 15 or 25 meters andretro-reflective with 7 metres.
2
Guaranteed to function under
Noise protection
Low temperature operationThe sensor operates perfectly even in temperatures from -5°C to +55°C.
Protection against
Liquids
Broad model rangeThe several available models practically service 100% of existing applications.
Thru-beam
Car Tyre alignment on conveyor belt Passing Objects in conveyor belt
Diffuse
Retro-Reflective
CXP LinePhotoelectric Sensors
Thru-Beam
25 m
15 m
infrared
red short
long
no
Type Sensing Distance Output
PNP/ NPN
ConnectionSystem
2 metercable
3 m
2 m
RangeLightSource
infrared
red
PolarizedFilter
yes
shortno
Diffuse 800 mm infrared -no
Reflective short
Model
OS800-CXP-PN
OR2KT-CXP-PN
OR3KF-CXP-PN
TR15K-CXP-PN
TR25K-CXP-PN
7 mReflective longOR7KF-CXP-PN red
Reflective*
M8connector
*Reflective for transparent objects.
Thru-Beam
The emitter and receiver are both independant units and should be placed facing each other so that the receiver continuouslylight from the emitter. Given the need for a variety of applications,sensors now have sensing distance up to 25 meters.
In this system, both transmitter and receiver are housed in the same module. In this model the light beam is reflected back to thereceiver by the object that is being detected.
With the transmitter and receiver housed in the same module, the emmited light beam only returns to the receiver by means ofa mirror or reflective tape. Given the need for a variety of applications, sensors now have sensing distance up to 7 meters.
3
User-friendly programmingallows for even beginnersto quickly learn how touse photoelectric sensors.
Sensing distance adjustment ismade by means of a magnetickey thus eliminating the need for physical buttons andproviding liquids ingress protection
All models are available with 3 pin or M8 4 pin power cable.
* Female connector not included
M8 Connector
2 meters
* Special lengths on demand
M8 - Straight M8 - Angled 90°
Cable
ModelsDiffuse
Thru-Beam
Easy to use
Easy to learn
Retro-Reflective
CXP LinePhotoelectric Sensors
4
1st - Distance
2nd - Light/ Dark
3rd - TimerMode
4th - Exit
3 seconds
sdnoces 3
Fine-Tuning Adjustments
Key
50 ms
100 ms
500 ms
1 touch
+ 1 touch
+ 1 touch
x meters
3s
3x3x
3s 3s
3s3s
GreenDistance
YellowL/D
Set ModeLed Flashing
10 - 30Vcc
BlueProg
3 - To program operating mode,use the magnetic activation key once again for 3 seconds. The YELLOWLED will blink 3 times showing the sensor has stored thesettings.Once settings have been finalized, sensor returns to operating mode.
3 - Ensure the object that is being detected is within the correct range. 4 - Use the magnetic activator key again for 3 seconds, The LED blinks 3 times,GREEN to show that sensor has stored the settings.
3 - To confirm timer ON option, use the magnetic activation key over the sensor for 3 seconds.The LED will blink once aRED second showing the first timer phase has been set.
4 - Use the magnetic activator key repeatedly over the sensor to select de-energization time delay. The LED will blink , once, twice or three times perRED second, showing respective timing selected.
NOTE 3: The sensor awaits operating mode confirmation for 30 seconds, following which it will automatically exit the configuration mode..
NOTE 4: The sensor awaits operating mode confirmation for 30 seconds, following which it will automatically exit the configuration mode..
NOTE 1:the sensor awaits distance confirmation for 30 seconds (depending on model) following which it will exit configuration mode
NOTE 2: In the event that adjustment is made with no object present(OS models) or mirror (OR models) or without the transmitter (TR models), the sensor will automatically store maximum distance.
NOTE 5: Above settings were made considering PNP sensor connection and readout in Light ON mode
5 - To adjust timer settings use the magnetic activator key for 3 seconds. The LED will blink 3 times,RED showing the sensor has stored the setting. On completion, the sensor will return to operating mode.
EnterSetup
Entering Setup Mode
Sensor Setup
To enter setup mode, the magnetic activation keymust be used for over three seconds.
Settings are made independantly by using themagnetic activation key when the respective LEDblinks:Distance Setup: LED blinkGREENOperating Mode : LED blinksYELLOWTimer Setup: LED blinks REDExit Setup LED blinks BLUE
Each LED will blink for a 3 second period and the magnetic activation key should be used during this time.Settings mode remains active for 30 seconds andthe 4 LEDS will blink alternately so that their respectivemode may be selected.
To exit settings mode, await the 30 second time lapseor use the magnetic activation key on the LEDBLUE while it blinks.
2 - Use the magnetic activation key repeatedly over the sensor in order to select timer ON/OFF. light on : Timer ONRED light off : Timer OFFRED
2 - Place target object, reflective mirror or emitter at the desired distance while observing allowable maximum distance for each specific model.
CXP LinePhotoelectric Sensors
5
DimensionsSensors
Cable Connectors
M8
9
,8
31,528
M8
9,8
19,5
37
1
2
11
.6
M8
x1
3.5
-5C
ab
le 28
19
0 mm
0 mm
25
12
M8
x1
3.5-5Cable
1 - Brown (+)
3 - Blue ( - )
Logics ControllerKFT-24025-FR24Vdc/2,5A
OutputDC 24Vcc/2,5A
Status
Adjust
Alarm
InputAC 100 to 240V0,7A 50-60Hz
www.sense.com.br
24V Power supply
3Negative
1Positive
4Output
31.8
mm
15 m
m
M3 (2x)
20 mm
12 mm
31.8
mm
M3 (2x)
20 mm
12 mm12 mm
31.8 mm 25,4 mmou 1"
20 mm
Brown or 1 pin
Blackor 4 pin
Blue or 3 pin
or10 to 30Vdc
10%
-
-
-
-
-
Mounting Bracket
4 - Black (PNP/NPN)
PNP or NPN
Universal PNP/NPN OutputFor CXP line sensors, control system card type is of no importance.The connection recognition circuit, allows the sensors to beconnected both to PNP as well as NPN cards, as it continuously monitors the ouput connection mode, thereby adjusting thesensor to the application.The recognition circuit eliminates output connection method , whether by switches , jumper leads or wiring which facilitates field installation, reducing connection errors which might damage the sensor.This feature not only facilitates field installation , but also assists in reducing the number of models in inventory,whichrepresents effective cost savings.
CXP LinePhotoelectric Sensors
MS-CXP-1
33
14
8
25
1,2
41
(2x) M3x18mm
3
24
22
5
14
6
1,2
5
M3x18mm
42
,5
25
12
MS-CXP2-1
6
CXP LinePhotoelectric Sensors
Cable models
Connector models
Light emitted
Sensing distance
Diffuse Reflective Thru-Beam
OS800-CXP-PN
OS800-CXP-PN-V84
OR3KF-CXP-PN
OR3KF-CXP-PN-V84
OR7KF-CXP-PN
OR7KF-CXP-PN-V84
OR2KT-CXP-PN
OR2KT-CXP-PN-V84
TR15K-CXP-PN
TR15K-CXP-PN-V84
TR25K-CXP-PN
TR25K-CXP-PN-V84
infrared
800 mm¹
Max. switching current
Minimum detectable object
Beam spot diameter
Color variation
Hysteresis
Repeatibility
Detectable object
Power supply
Ripple
Current consumption
Residual current
Minimum current
Voltage drop
Response time
Operation Frequency
Output protection
Output settings
Green LED
Yellow LED
Red LED
Blue LED
Immunity to sunlight
Imun. to incandescent light
Imun. to fluorescent light
Immunity to LED light
Operation temperature
Humidity
Protection class
Weight
Connection - Cable
Connection - Connector
Housing
Fine-tune adjustment yes - magnetic
-
-
8%
10 mm
opaque, translucent
10 to 30 Vdc
10%
100 mA
2,5 ms
2 V
1 mA
0.5 mA
60 Hz
short circuit and reverse
light on or dark on, via magnetic key
power / stability / distance setting
status output / output configuration
timer setting
setting assisant
10.000 lux
10.000 lux (frontal)
- 5°C to +55°C
35% to 85% UR
IP65, IP66, IP67
10.000 lux (frontal)
10.000 lux (frontal)
cable: ~50g / connector: ~9g cable: ~100g / connector: ~20g
PVC 2 m - 3 x 0.2 m² wire
4 pins
PBT and acrylic lens
infrared
20 to 2000 mm
yes - magnetic
Ø 1 mm
-
-
-
1 mm
transparent
red
20 to 3000 mm
yes - magnetic
Ø 5 mm
-
-
-
1.5 mm
opaque, translucent
red
500 to 7000 mm
yes - magnetic
Ø 5 mm
-
-
-
1.5 mm
opaque, translucent
red
15 m
yes - magnetic
Ø 3 mm²
-
-
-
-
opaque
infrared
25 m
yes - magnetic
Ø 3 mm³
-
-
-
-
opaque
² For distance below 1 meter between transmitter and the receiver, the minimum detectable object is 6 mm.³ For distance below 3 meter between transmitter and the receiver, the minimum detectable object is 10 mm.
-
< 23 mA < 8 mA < 23 mA < 23 mA TO: < 21mA and RO: < 7mA
100 Hz
¹ The nominal sensing range is specified for a 200 x 200mm white paper . There are restrictions on the size and color of the object to distance adjustments less than 250mm.
www.sense.com.brInformation herein contained is subject to change without prior notice. 2000000294 Rev. Q - 12/2015
Acessories
Mounting Brackets
Source current 90 to 264Vac 24Vcc/ 1A output current Plug-in terminal block connectionRedundant connectionShort circuit protectionPlastic housing
Current 110 or 220Vac
Activation timer
Straight and 90° models
Four gold plated contacts
* Please check and consult for other lengths and materials
Straight and angled 90° models
Four gold plated contacts
Reflective tape
Twin screw fixture
Reflective tapeSquare Twin screw fixture
Reflective tapeRound Twin screw fixture
Reflective tapeRound Single screw fixture
Reflective tapeRound Single screw fixture
Stainless steel bracketFor vertical installation2 screws included
Authorized DistributorHEAD OFFICE - SÃO PAULO
Rua Tuiuti, 1237 - TatuapéSão Paulo - SP - Cep: 03081-000
Phone: (55-11) [email protected]
FACTORY - MINAS GERAIS Av. Joaquim M. Carneiro. 600 - Santana
Sta. Rita do Sapucaí - MG - Cep: 37540-000Phone: (55-35) 3471-2555
M8 metallic thread coupling
2 meter cable length
LED indication display modelsPVC or PU injected cables
PVC Housing
Mountable connectors
M8 metallic coupling
35mm DIN rail mount 35mm DIN rail mount
Plastic housingShort circuit protectionLED Display
Plug-in terminal block connectionPNP sensor connection
Rectangular
Current 110 or 220VacPNP sensor connection Plug-in terminal block connection Activation timerLED DisplayShort circuit protectionPlastic housing
35mm DIN rail mount
KD-103P/110-220Vac-P KD-103N/110-220Vac-P
CXP LinePhotoelectric Sensors
MS-CXP-1 MS-CXP2-1
Stainless steel bracketFor vertical installation2 screws included
Top Related