Photoelectric Sensors - Baldota · Photoelectric Sensors Examples of Applications Compact...

8

Transcript of Photoelectric Sensors - Baldota · Photoelectric Sensors Examples of Applications Compact...

1

Photoelectric Sensors

Examples of Applications

Compact Dimensions

Long Distance Sensing

Detection of boxes on conveyor belts Detection of plastic bottles

Models detect objects as far as 25 meters away.

Reduction of up to 40% in energy consumptionwhen compared to other series

Detection of plastic bottle caps

12 mm

31.8 mm

20 mm

25,4 mmou 1"

1" Standard mounting holesOR3KF-CXP-PN

GreenPower

Run Mode

YellowOutput

BlueMagneticButtom

CXP Line

A magnetic key is all that is needed to configurethe sensor.After a few steps the , the sensor is ready for use.

Increased Sensing DistânceThru-Beam models with 15 or 25 meters andretro-reflective with 7 metres.

2

Guaranteed to function under

Noise protection

Low temperature operationThe sensor operates perfectly even in temperatures from -5°C to +55°C.

Protection against

Liquids

Broad model rangeThe several available models practically service 100% of existing applications.

Thru-beam

Car Tyre alignment on conveyor belt Passing Objects in conveyor belt

Diffuse

Retro-Reflective

CXP LinePhotoelectric Sensors

Thru-Beam

25 m

15 m

infrared

red short

long

no

Type Sensing Distance Output

PNP/ NPN

ConnectionSystem

2 metercable

3 m

2 m

RangeLightSource

infrared

red

PolarizedFilter

yes

shortno

Diffuse 800 mm infrared -no

Reflective short

Model

OS800-CXP-PN

OR2KT-CXP-PN

OR3KF-CXP-PN

TR15K-CXP-PN

TR25K-CXP-PN

7 mReflective longOR7KF-CXP-PN red

Reflective*

M8connector

*Reflective for transparent objects.

Thru-Beam

The emitter and receiver are both independant units and should be placed facing each other so that the receiver continuouslylight from the emitter. Given the need for a variety of applications,sensors now have sensing distance up to 25 meters.

In this system, both transmitter and receiver are housed in the same module. In this model the light beam is reflected back to thereceiver by the object that is being detected.

With the transmitter and receiver housed in the same module, the emmited light beam only returns to the receiver by means ofa mirror or reflective tape. Given the need for a variety of applications, sensors now have sensing distance up to 7 meters.

3

User-friendly programmingallows for even beginnersto quickly learn how touse photoelectric sensors.

Sensing distance adjustment ismade by means of a magnetickey thus eliminating the need for physical buttons andproviding liquids ingress protection

All models are available with 3 pin or M8 4 pin power cable.

* Female connector not included

M8 Connector

2 meters

* Special lengths on demand

M8 - Straight M8 - Angled 90°

Cable

ModelsDiffuse

Thru-Beam

Easy to use

Easy to learn

Retro-Reflective

CXP LinePhotoelectric Sensors

4

1st - Distance

2nd - Light/ Dark

3rd - TimerMode

4th - Exit

3 seconds

sdnoces 3

Fine-Tuning Adjustments

Key

50 ms

100 ms

500 ms

1 touch

+ 1 touch

+ 1 touch

x meters

3s

3x3x

3s 3s

3s3s

GreenDistance

YellowL/D

Set ModeLed Flashing

10 - 30Vcc

BlueProg

3 - To program operating mode,use the magnetic activation key once again for 3 seconds. The YELLOWLED will blink 3 times showing the sensor has stored thesettings.Once settings have been finalized, sensor returns to operating mode.

3 - Ensure the object that is being detected is within the correct range. 4 - Use the magnetic activator key again for 3 seconds, The LED blinks 3 times,GREEN to show that sensor has stored the settings.

3 - To confirm timer ON option, use the magnetic activation key over the sensor for 3 seconds.The LED will blink once aRED second showing the first timer phase has been set.

4 - Use the magnetic activator key repeatedly over the sensor to select de-energization time delay. The LED will blink , once, twice or three times perRED second, showing respective timing selected.

NOTE 3: The sensor awaits operating mode confirmation for 30 seconds, following which it will automatically exit the configuration mode..

NOTE 4: The sensor awaits operating mode confirmation for 30 seconds, following which it will automatically exit the configuration mode..

NOTE 1:the sensor awaits distance confirmation for 30 seconds (depending on model) following which it will exit configuration mode

NOTE 2: In the event that adjustment is made with no object present(OS models) or mirror (OR models) or without the transmitter (TR models), the sensor will automatically store maximum distance.

NOTE 5: Above settings were made considering PNP sensor connection and readout in Light ON mode

5 - To adjust timer settings use the magnetic activator key for 3 seconds. The LED will blink 3 times,RED showing the sensor has stored the setting. On completion, the sensor will return to operating mode.

EnterSetup

Entering Setup Mode

Sensor Setup

To enter setup mode, the magnetic activation keymust be used for over three seconds.

Settings are made independantly by using themagnetic activation key when the respective LEDblinks:Distance Setup: LED blinkGREENOperating Mode : LED blinksYELLOWTimer Setup: LED blinks REDExit Setup LED blinks BLUE

Each LED will blink for a 3 second period and the magnetic activation key should be used during this time.Settings mode remains active for 30 seconds andthe 4 LEDS will blink alternately so that their respectivemode may be selected.

To exit settings mode, await the 30 second time lapseor use the magnetic activation key on the LEDBLUE while it blinks.

2 - Use the magnetic activation key repeatedly over the sensor in order to select timer ON/OFF. light on : Timer ONRED light off : Timer OFFRED

2 - Place target object, reflective mirror or emitter at the desired distance while observing allowable maximum distance for each specific model.

CXP LinePhotoelectric Sensors

5

DimensionsSensors

Cable Connectors

M8

9

,8

31,528

M8

9,8

19,5

37

1

2

11

.6

M8

x1

3.5

-5C

ab

le 28

19

0 mm

0 mm

25

12

M8

x1

3.5-5Cable

1 - Brown (+)

3 - Blue ( - )

Logics ControllerKFT-24025-FR24Vdc/2,5A

OutputDC 24Vcc/2,5A

Status

Adjust

Alarm

InputAC 100 to 240V0,7A 50-60Hz

www.sense.com.br

24V Power supply

3Negative

1Positive

4Output

31.8

mm

15 m

m

M3 (2x)

20 mm

12 mm

31.8

mm

M3 (2x)

20 mm

12 mm12 mm

31.8 mm 25,4 mmou 1"

20 mm

Brown or 1 pin

Blackor 4 pin

Blue or 3 pin

or10 to 30Vdc

10%

-

-

-

-

-

Mounting Bracket

4 - Black (PNP/NPN)

PNP or NPN

Universal PNP/NPN OutputFor CXP line sensors, control system card type is of no importance.The connection recognition circuit, allows the sensors to beconnected both to PNP as well as NPN cards, as it continuously monitors the ouput connection mode, thereby adjusting thesensor to the application.The recognition circuit eliminates output connection method , whether by switches , jumper leads or wiring which facilitates field installation, reducing connection errors which might damage the sensor.This feature not only facilitates field installation , but also assists in reducing the number of models in inventory,whichrepresents effective cost savings.

CXP LinePhotoelectric Sensors

MS-CXP-1

33

14

8

25

1,2

41

(2x) M3x18mm

3

24

22

5

14

6

1,2

5

M3x18mm

42

,5

25

12

MS-CXP2-1

6

CXP LinePhotoelectric Sensors

Cable models

Connector models

Light emitted

Sensing distance

Diffuse Reflective Thru-Beam

OS800-CXP-PN

OS800-CXP-PN-V84

OR3KF-CXP-PN

OR3KF-CXP-PN-V84

OR7KF-CXP-PN

OR7KF-CXP-PN-V84

OR2KT-CXP-PN

OR2KT-CXP-PN-V84

TR15K-CXP-PN

TR15K-CXP-PN-V84

TR25K-CXP-PN

TR25K-CXP-PN-V84

infrared

800 mm¹

Max. switching current

Minimum detectable object

Beam spot diameter

Color variation

Hysteresis

Repeatibility

Detectable object

Power supply

Ripple

Current consumption

Residual current

Minimum current

Voltage drop

Response time

Operation Frequency

Output protection

Output settings

Green LED

Yellow LED

Red LED

Blue LED

Immunity to sunlight

Imun. to incandescent light

Imun. to fluorescent light

Immunity to LED light

Operation temperature

Humidity

Protection class

Weight

Connection - Cable

Connection - Connector

Housing

Fine-tune adjustment yes - magnetic

-

-

8%

10 mm

opaque, translucent

10 to 30 Vdc

10%

100 mA

2,5 ms

2 V

1 mA

0.5 mA

60 Hz

short circuit and reverse

light on or dark on, via magnetic key

power / stability / distance setting

status output / output configuration

timer setting

setting assisant

10.000 lux

10.000 lux (frontal)

- 5°C to +55°C

35% to 85% UR

IP65, IP66, IP67

10.000 lux (frontal)

10.000 lux (frontal)

cable: ~50g / connector: ~9g cable: ~100g / connector: ~20g

PVC 2 m - 3 x 0.2 m² wire

4 pins

PBT and acrylic lens

infrared

20 to 2000 mm

yes - magnetic

Ø 1 mm

-

-

-

1 mm

transparent

red

20 to 3000 mm

yes - magnetic

Ø 5 mm

-

-

-

1.5 mm

opaque, translucent

red

500 to 7000 mm

yes - magnetic

Ø 5 mm

-

-

-

1.5 mm

opaque, translucent

red

15 m

yes - magnetic

Ø 3 mm²

-

-

-

-

opaque

infrared

25 m

yes - magnetic

Ø 3 mm³

-

-

-

-

opaque

² For distance below 1 meter between transmitter and the receiver, the minimum detectable object is 6 mm.³ For distance below 3 meter between transmitter and the receiver, the minimum detectable object is 10 mm.

-

< 23 mA < 8 mA < 23 mA < 23 mA TO: < 21mA and RO: < 7mA

100 Hz

¹ The nominal sensing range is specified for a 200 x 200mm white paper . There are restrictions on the size and color of the object to distance adjustments less than 250mm.

www.sense.com.brInformation herein contained is subject to change without prior notice. 2000000294 Rev. Q - 12/2015

Acessories

Mounting Brackets

Source current 90 to 264Vac 24Vcc/ 1A output current Plug-in terminal block connectionRedundant connectionShort circuit protectionPlastic housing

Current 110 or 220Vac

Activation timer

Straight and 90° models

Four gold plated contacts

* Please check and consult for other lengths and materials

Straight and angled 90° models

Four gold plated contacts

Reflective tape

Twin screw fixture

Reflective tapeSquare Twin screw fixture

Reflective tapeRound Twin screw fixture

Reflective tapeRound Single screw fixture

Reflective tapeRound Single screw fixture

Stainless steel bracketFor vertical installation2 screws included

Authorized DistributorHEAD OFFICE - SÃO PAULO

Rua Tuiuti, 1237 - TatuapéSão Paulo - SP - Cep: 03081-000

Phone: (55-11) [email protected]

FACTORY - MINAS GERAIS Av. Joaquim M. Carneiro. 600 - Santana

Sta. Rita do Sapucaí - MG - Cep: 37540-000Phone: (55-35) 3471-2555

M8 metallic thread coupling

2 meter cable length

LED indication display modelsPVC or PU injected cables

PVC Housing

Mountable connectors

M8 metallic coupling

35mm DIN rail mount 35mm DIN rail mount

Plastic housingShort circuit protectionLED Display

Plug-in terminal block connectionPNP sensor connection

Rectangular

Current 110 or 220VacPNP sensor connection Plug-in terminal block connection Activation timerLED DisplayShort circuit protectionPlastic housing

35mm DIN rail mount

KD-103P/110-220Vac-P KD-103N/110-220Vac-P

CXP LinePhotoelectric Sensors

MS-CXP-1 MS-CXP2-1

Stainless steel bracketFor vertical installation2 screws included