(English) (CP10-12CW1)
CP10CW1 CP12CW1
®
OWNER’S MANUALPortable Refrigerated Air Conditioner
®
i CP10-12CW1 Portable Refrigerated Air Conditioner
Please read these instructions prior to using the appliance andsave them for future reference.
Waste electrical products must not be disposed of with householdwaste. This product should be taken to your local recycling centre forsafe treatment.
CONTENTSIntroduction......................................1
Safety ..............................................2
Component location.........................3
Installing the exhaust hose ..............4
Control panel ...................................5
Remote control ................................6
Operation......................................7-8
Maintenance ....................................9
Troubleshooting .............................10
Specifications.................................11
Warranty ........................................12
SEELEY INTERNATIONAL – OWNER’S MANUAL
THANK YOU for choosing a ConvairAir Conditioner. This appliance hasbeen carefully engineered to bring youtrouble-free personal air conditioning.Please read this manual carefully sothat you take full advantage of themany benefits your Convair provides.
This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities,or lack of experience and knowledge,unless they have been given supervisionor instruction in using the appliance by aperson responsible for their safety.
Children should be supervised to ensurethat they do not play with the appliance.Do not place anything through theventilating slots.
Your Convair cooler is a portable airconditioning unit that supplies refrigeratedair to a personal area within a room. It isnot intended to function as a house orroom air conditioner.
Be sure the appliance has been securelyand correctly installed according to theinstallation instructions contained withinthis manual.
Personal Cooling
Energy Saving Tips
Warranty
D
D
D
D
D
Do not locate the air conditioner wherefurniture or other objects can obstruct theair flow.Keep curtains and blinds closed duringthe hottest part of the day.Keep the filters clean.Set the air conditioner to maximumcooling and high fan speed initially, thenadjust to a comfortable setting.Do not wait until the room is excessivelyhot before using the air conditioner.
Convair air conditioners are warrantedagainst faulty manufacture for 2 years afterpurchase. Please refer to page 12 for moredetails on warranty.
1
INTRODUCTION
i CP10-12CW1 Portable Refrigerated Air Conditioner
Please read these instructions prior to using the appliance andsave them for future reference.
Waste electrical products must not be disposed of with householdwaste. This product should be taken to your local recycling centre forsafe treatment.
CONTENTSIntroduction......................................1
Safety ..............................................2
Component location.........................3
Installing the exhaust hose ..............4
Control panel ...................................5
Remote control ................................6
Operation......................................7-8
Maintenance ....................................9
Troubleshooting .............................10
Specifications.................................11
Warranty ........................................12
SEELEY INTERNATIONAL – OWNER’S MANUAL
THANK YOU for choosing a ConvairAir Conditioner. This appliance hasbeen carefully engineered to bring youtrouble-free personal air conditioning.Please read this manual carefully sothat you take full advantage of themany benefits your Convair provides.
This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities,or lack of experience and knowledge,unless they have been given supervisionor instruction in using the appliance by aperson responsible for their safety.
Children should be supervised to ensurethat they do not play with the appliance.Do not place anything through theventilating slots.
Your Convair cooler is a portable airconditioning unit that supplies refrigeratedair to a personal area within a room. It isnot intended to function as a house orroom air conditioner.
Be sure the appliance has been securelyand correctly installed according to theinstallation instructions contained withinthis manual.
Personal Cooling
Energy Saving Tips
Warranty
D
D
D
D
D
Do not locate the air conditioner wherefurniture or other objects can obstruct theair flow.Keep curtains and blinds closed duringthe hottest part of the day.Keep the filters clean.Set the air conditioner to maximumcooling and high fan speed initially, thenadjust to a comfortable setting.Do not wait until the room is excessivelyhot before using the air conditioner.
Convair air conditioners are warrantedagainst faulty manufacture for 2 years afterpurchase. Please refer to page 12 for moredetails on warranty.
1
INTRODUCTION
®
®
SAFETY
For indoor use only.
Ensure the appliance has been installed inaccordance with national wiring regulations.
Transport the air conditioner in anupright position only, or leave it in anupright position for at least 2 hoursbefore use (Fig 1).
Use only in the upright position on a flatlevel surface and at least 50cm from anyobjects.
Do not place objects on the air conditioner,or through the ventilating slots or restrict theair inlets & outlets (Fig 2).
Closely supervise any children and petswhen the air conditioner is in use.
Electrical Safety
Do not store or operate the appliance nearany flammable substances.
During operation, water will collect in thebottom tank of the air conditioner. Becareful when moving the unit to preventwater from spilling.
Electrical Safety (cont)
Caution! before connecting theelectrical power cord to a power outlet,check that the air conditioner voltageis the same as your power supply (referto the rating label located on the back ofthe unit - refer Fig 4). Ensure the powersupply is correctly earthed and rated.
Plug the air conditioner directly into aproperly installed power outlet. Never usean extension cord, double adaptor ormulti-power outlet board to run this airconditioner.
Do not pull the unit along by the powercord or place the power cord near asource of heat. Always unroll the powercord completely before use.
Switch off and unplug when not in use.
Do not use in humid environments suchas bathrooms, laundries or other steamyor wet areas.
Do not touch or operate the airconditioner with wet or damp hands orwhen standing barefoot.
If the power supply cord is damaged itmust be replaced by the manufacturer, aservice agent or similarly qualifiedpersons in order to avoid a hazard.
2
1
CP10-12CW1 Portable Refrigerated Air Conditioner2
®
4
3
RemoteControl
RemoteControl
(inc. batteries)
Air Outlet
Handle
Handle
Vane Lever
Display Panel
Control Panel
Air Filter
Air FilterDrain
Air Intake
PowerCord
Exhaust AirOutlet
Exhaust Hose
Exhaust Hose
Window Attachment
Window Attachment
Exhaust Fitting(window end)
Screws (6)
Screws (6)
Exhaust Fitting(window end)
RatingLabel
CordStorageHooks
COMPONENT LOCATION
SEELEY INTERNATIONAL – OWNER’S MANUAL 3
®
®
SAFETY
For indoor use only.
Ensure the appliance has been installed inaccordance with national wiring regulations.
Transport the air conditioner in anupright position only, or leave it in anupright position for at least 2 hoursbefore use (Fig 1).
Use only in the upright position on a flatlevel surface and at least 50cm from anyobjects.
Do not place objects on the air conditioner,or through the ventilating slots or restrict theair inlets & outlets (Fig 2).
Closely supervise any children and petswhen the air conditioner is in use.
Electrical Safety
Do not store or operate the appliance nearany flammable substances.
During operation, water will collect in thebottom tank of the air conditioner. Becareful when moving the unit to preventwater from spilling.
Electrical Safety (cont)
Caution! before connecting theelectrical power cord to a power outlet,check that the air conditioner voltageis the same as your power supply (referto the rating label located on the back ofthe unit - refer Fig 4). Ensure the powersupply is correctly earthed and rated.
Plug the air conditioner directly into aproperly installed power outlet. Never usean extension cord, double adaptor ormulti-power outlet board to run this airconditioner.
Do not pull the unit along by the powercord or place the power cord near asource of heat. Always unroll the powercord completely before use.
Switch off and unplug when not in use.
Do not use in humid environments suchas bathrooms, laundries or other steamyor wet areas.
Do not touch or operate the airconditioner with wet or damp hands orwhen standing barefoot.
If the power supply cord is damaged itmust be replaced by the manufacturer, aservice agent or similarly qualifiedpersons in order to avoid a hazard.
2
1
CP10-12CW1 Portable Refrigerated Air Conditioner2
®
4
3
RemoteControl
RemoteControl
(inc. batteries)
Air Outlet
Handle
Handle
Vane Lever
Display Panel
Control Panel
Air Filter
Air FilterDrain
Air Intake
PowerCord
Exhaust AirOutlet
Exhaust Hose
Exhaust Hose
Window Attachment
Window Attachment
Exhaust Fitting(window end)
Screws (6)
Screws (6)
Exhaust Fitting(window end)
RatingLabel
CordStorageHooks
COMPONENT LOCATION
SEELEY INTERNATIONAL – OWNER’S MANUAL 3
INSTALLING THE EXHAUST HOSE
Step 1:
Step 2:
Step 3:
Fit the exhaust hose to the rearpanel outlet by screwing the hose in aclockwise direction. Fit the window adaptoronto the hose by rotating the adaptor in aclockwise direction.
Screw the round window adaptorinto position on the window attachment withthe screws (4) provided.
Open the window and fit theadjustable window attachment. Extend theattachment as required and lock into placewith the screws (2) provided. Ensure theoutlet is not obscured. The windowattachment can be installed horizontally orvertically, depending on the window type.
Note!
Note!
The minimum distance requiredfrom the operating air conditioner toany obstructing objects or walls is50cm (Fig 6).
Keep the exhaust hose as short andstraight as possible and minimisekinks. This will maximise the coolingperformance.
Don’t use extension pieces for theexhaust pipe as this will reduce thecooling performance and possiblyresult in damage to the air conditioner.
Hot air and possibly mist will beemitted from the exhaust hose.
It is critical to the cooler’sperformance that the hot exhaust air iscompletely removed from the spacebeing cooled.
5
50cm
6
CP10-12CW1 Portable Refrigerated Air Conditioner4
Sleepbutton
Swingbutton
Press to enter thesleep mode
Press to activateleft/right swing vanes
To avoid damage to the control panel, do not operate with sharp objects.NOTE!
7
CONTROL PANEL
Press to cycle fromCooling, Dehumidifying
and Fan modes.
Press to enter thetimer setting mode
and time
Press to turn theair conditioner on
and off
Press + to increase,- to decrease theset temperature
Press to cycle the fanspeed between low
and high
Power ON / OFFbutton
Timer Setbutton
Mode Selectbutton
Temperature adjustbuttons
Fan Speedcontrol button
ModeIndicator
Fan SpeedIndicator
WaterFull
Indicator
Set TempDisplay
CompressorOn
Indicator
POWERIndicator
SWING TIMER SLEEP UP
WATER FULL COMP.
HIGH
LOW
COOL
DEHUM
FAN
DOWN SPEED MODE POWER
SEELEY INTERNATIONAL – OWNER’S MANUAL 5
INSTALLING THE EXHAUST HOSE
Step 1:
Step 2:
Step 3:
Fit the exhaust hose to the rearpanel outlet by screwing the hose in aclockwise direction. Fit the window adaptoronto the hose by rotating the adaptor in aclockwise direction.
Screw the round window adaptorinto position on the window attachment withthe screws (4) provided.
Open the window and fit theadjustable window attachment. Extend theattachment as required and lock into placewith the screws (2) provided. Ensure theoutlet is not obscured. The windowattachment can be installed horizontally orvertically, depending on the window type.
Note!
Note!
The minimum distance requiredfrom the operating air conditioner toany obstructing objects or walls is50cm (Fig 6).
Keep the exhaust hose as short andstraight as possible and minimisekinks. This will maximise the coolingperformance.
Don’t use extension pieces for theexhaust pipe as this will reduce thecooling performance and possiblyresult in damage to the air conditioner.
Hot air and possibly mist will beemitted from the exhaust hose.
It is critical to the cooler’sperformance that the hot exhaust air iscompletely removed from the spacebeing cooled.
5
50cm
6
CP10-12CW1 Portable Refrigerated Air Conditioner4
Sleepbutton
Swingbutton
Press to enter thesleep mode
Press to activateleft/right swing vanes
To avoid damage to the control panel, do not operate with sharp objects.NOTE!
7
CONTROL PANEL
Press to cycle fromCooling, Dehumidifying
and Fan modes.
Press to enter thetimer setting mode
and time
Press to turn theair conditioner on
and off
Press + to increase,- to decrease theset temperature
Press to cycle the fanspeed between low
and high
Power ON / OFFbutton
Timer Setbutton
Mode Selectbutton
Temperature adjustbuttons
Fan Speedcontrol button
ModeIndicator
Fan SpeedIndicator
WaterFull
Indicator
Set TempDisplay
CompressorOn
Indicator
POWERIndicator
SWING TIMER SLEEP UP
WATER FULL COMP.
HIGH
LOW
COOL
DEHUM
FAN
DOWN SPEED MODE POWER
SEELEY INTERNATIONAL – OWNER’S MANUAL 5
If there are two of the same airconditioners installed, they cannot becontrolled separately. When you operateeither remote, it will turn on both airconditioners if they are both within signalrange (6 metres).
Don’t let the remote control drop ontohard surfaces or be subjected to suddenshocks in any way. The warranty does notcover misuse or accidental damage.
Don’t place the remote control in directsunlight, or near extremes of temperature.This will affect the control’s temperaturereading.
Don’t allow the remote control to get wet.
Don’t place near strong electromagneticwaves.
Don’t mix old and new batteries!If the remote control will not be used for along time, remove the batteries to avoidcorrosion.
Care of your remote control
Preparation before operation
During Operation
Remove the battery cover and insert newbatteries
.
Remove the batteries and replace with newones. If this does not solve the problemcontact your nearest service centre foradvice.
(AAA), making sure the + and - arematching the compartment markings (Fig 9)
If the remote control will not operate the airconditioner, the batteries may need to bereplaced.
The air conditioner must be plugged inand switched on for the remote control tooperate the air conditioner. To use, point atthe signal receiving window on the frontpanel and press the remote button. The airconditioner will “beep” when a signal hasbeen received. If there is no beep, press theremote button again, ensuring it is withinrange (6 metres) of the air conditioner.
Note!
!NOTE:WASTE BATTERIES SHOULD
BE DISPOSED OF CORRECTLY
REMOTE CONTROL
8Signaltransmission point
Temperatureadjust buttons
Sleep mode button
Swing button
Fan speedadjust button Mode buttons
(Cool-Dehumidify-Fan)
Timer on / adjustbutton
Power ON / OFFbutton
Batterycompartment
Battery cover
9
CP10-12CW1 Portable Refrigerated Air Conditioner6
®
Note!
Important!
Step 6:
In Cooling mode, the fan will continueto run even when the compressor hascycled off.
The air conditioner is fitted with 2sets of air direction vanes.
Horizontal vanes will cycle left to rightautomatically by pressing the SWING buttonon the remote control or control panel (Fig7, 10).
Vertical vanes - carefully move the vanesto the desired position by hand (Fig 11).
During cooling mode, water willcollect in the air conditioner’s tank. Thiswater is recirculated and some will beexhausted out with the hot air, but will slowlyfill up the tank. This occurs more quickly inhumid conditions. If the tank should fill, the‘water full’ indicator will be lit on the controldisplay, the unit will ‘beep’ and then shutdown. The cooler cannot be restarted untilthe water tank is drained. Refer to theMaintenance section for draining the tankshould this occur.
!
!
Starting the air conditioner
Step 1: Ensure the cooler is plugged inand switched on.
!
!
!
Step 2:
Step 3:
Cooling mode
Dehumidifying mode
Fan mode
Step 4:
!
Step 5:
Press the ON/OFF buttonon the remote control or ON/OFF
button on the control panel to start the airconditioner.
Press the MODE button onthe control panel or remote control toselect the desired operating mode (Fig.7&10):
- refrigerated
cooling
- for extractingmoisture from the air
- Fan only operation (nocooling)
Press / - on the control panelor / on the remote control to selectthe desired operating ‘set’ temperature.
In Cooling mode, cooling will occur if theset temperature is less than the roomtemperature.
Do not set the cooling temperaturetoo low. This will consume more power.24°C is the recommended settemperature, with high fan speed.
Changing the set temperature willhave no effect in DEHUMIDIFYING orFAN modes.
Press the FAN SPEED buttonon the control panel or remote control
to adjust the fan speed. Each press willcycle the fan speed between low andhigh.
+p q
The set temperature range is 16°C-31°C
Tip
Note!
OPERATION
Step.2
Step.8
Step.3Step.5
Step.4
Step.7
Step.6
10
11
SEELEY INTERNATIONAL – OWNER’S MANUAL 7
If there are two of the same airconditioners installed, they cannot becontrolled separately. When you operateeither remote, it will turn on both airconditioners if they are both within signalrange (6 metres).
Don’t let the remote control drop ontohard surfaces or be subjected to suddenshocks in any way. The warranty does notcover misuse or accidental damage.
Don’t place the remote control in directsunlight, or near extremes of temperature.This will affect the control’s temperaturereading.
Don’t allow the remote control to get wet.
Don’t place near strong electromagneticwaves.
Don’t mix old and new batteries!If the remote control will not be used for along time, remove the batteries to avoidcorrosion.
Care of your remote control
Preparation before operation
During Operation
Remove the battery cover and insert newbatteries
.
Remove the batteries and replace with newones. If this does not solve the problemcontact your nearest service centre foradvice.
(AAA), making sure the + and - arematching the compartment markings (Fig 9)
If the remote control will not operate the airconditioner, the batteries may need to bereplaced.
The air conditioner must be plugged inand switched on for the remote control tooperate the air conditioner. To use, point atthe signal receiving window on the frontpanel and press the remote button. The airconditioner will “beep” when a signal hasbeen received. If there is no beep, press theremote button again, ensuring it is withinrange (6 metres) of the air conditioner.
Note!
!NOTE:WASTE BATTERIES SHOULD
BE DISPOSED OF CORRECTLY
REMOTE CONTROL
8Signaltransmission point
Temperatureadjust buttons
Sleep mode button
Swing button
Fan speedadjust button Mode buttons
(Cool-Dehumidify-Fan)
Timer on / adjustbutton
Power ON / OFFbutton
Batterycompartment
Battery cover
9
CP10-12CW1 Portable Refrigerated Air Conditioner6
®
Note!
Important!
Step 6:
In Cooling mode, the fan will continueto run even when the compressor hascycled off.
The air conditioner is fitted with 2sets of air direction vanes.
Horizontal vanes will cycle left to rightautomatically by pressing the SWING buttonon the remote control or control panel (Fig7, 10).
Vertical vanes - carefully move the vanesto the desired position by hand (Fig 11).
During cooling mode, water willcollect in the air conditioner’s tank. Thiswater is recirculated and some will beexhausted out with the hot air, but will slowlyfill up the tank. This occurs more quickly inhumid conditions. If the tank should fill, the‘water full’ indicator will be lit on the controldisplay, the unit will ‘beep’ and then shutdown. The cooler cannot be restarted untilthe water tank is drained. Refer to theMaintenance section for draining the tankshould this occur.
!
!
Starting the air conditioner
Step 1: Ensure the cooler is plugged inand switched on.
!
!
!
Step 2:
Step 3:
Cooling mode
Dehumidifying mode
Fan mode
Step 4:
!
Step 5:
Press the ON/OFF buttonon the remote control or ON/OFF
button on the control panel to start the airconditioner.
Press the MODE button onthe control panel or remote control toselect the desired operating mode (Fig.7&10):
- refrigerated
cooling
- for extractingmoisture from the air
- Fan only operation (nocooling)
Press / - on the control panelor / on the remote control to selectthe desired operating ‘set’ temperature.
In Cooling mode, cooling will occur if theset temperature is less than the roomtemperature.
Do not set the cooling temperaturetoo low. This will consume more power.24°C is the recommended settemperature, with high fan speed.
Changing the set temperature willhave no effect in DEHUMIDIFYING orFAN modes.
Press the FAN SPEED buttonon the control panel or remote control
to adjust the fan speed. Each press willcycle the fan speed between low andhigh.
+p q
The set temperature range is 16°C-31°C
Tip
Note!
OPERATION
Step.2
Step.8
Step.3Step.5
Step.4
Step.7
Step.6
10
11
SEELEY INTERNATIONAL – OWNER’S MANUAL 7
OPERATION cont.
Air Conditioner Features
Step 7:
Timer Function
Step 8: Setting the timer
Your air conditioner has a SLEEPmode, activated by pressing the button onthe control panel or remote control. SLEEPmode will change the fan speed to low andincrease the set temperature by 1°C eachhour for 2 hours. No further change willoccur after the 2nd hour.
Sleep Mode can only be used duringCooling mode, and will be cancelled if theMODE is changed, the cooler goes intostandby or the ‘Water Full’ alert occurs.
The air conditioner is fitted with a timerfunction. This can be set up to 24 hours inadvance. To use this function, the coolermust be plugged in and ready to operate.
With the air conditioner ON, press theTIMER button on the remote control orcontrol panel. The control panel display willflash and show the time setting. Press theTIMER button to increase the time in 1 hourincrements from 1 - 24 hrs. After 3 secondsthe display will revert to the SETtemperature.
When the air conditioner is OFF (but stillplugged in), repeat the above to set the ONtime. The air conditioner will start up withthe last settings used.
When the air conditioner is working,only the TIMER OFF can be set. When theair conditioner is off, only the TIMER ONcan be set.
Note!
How to cancel the timer
00To cancel the timer, set the time tousing the control panel or remote control.The TIMER indicator will stop glowing.
CP10-12CW1 Portable Refrigerated Air Conditioner8
Draining the Air Conditioner
To drain the air conditioner, place it over adrain point before unscrewing the cap andremoving the drain plug, as water will flowout as soon as the plug is removed.Remove the plug at the bottom rear of theappliance and allow the tank tocompletely drain (Fig 12B).
Note! Always replace the drain plugimmediately after draining.
Always disconnect the air conditioner from the electricity mains before cleaning ordraining.
To maximize the efficiency of the air conditioner, clean regularly.
Never operate the air conditioner without the filters.
Cleaning the housing
Cleaning the filters
Note!
Use a soft, damp cloth to wipe the body clean.Never use aggressive chemicals, spirits, detergents, chemically treated cloths, or othercleansing solutions. These substances could possibly damage the cabinet
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinseunder running water (no hotter than 40°C).Dry thoroughly before replacing.Take care to replace the filters back into the slots in the cooler.
.
Remove the filters from the top and bottom air inlet vents as shown (Fig 12A).
End of season storage:• Drain any water from the unit.
• Operate the unit in fan only mode for a few hours, to thoroughly dry the inside.
• Clean or change the filters.
• Replace in the original carton or cover for storage.
• Unplug and carefully store the power cord and plug end.
MAINTENANCE
B
12 A
Remove all filters (4 total)from the air conditionerand clean every 2 weeks.
SEELEY INTERNATIONAL – OWNER’S MANUAL 9
OPERATION cont.
Air Conditioner Features
Step 7:
Timer Function
Step 8: Setting the timer
Your air conditioner has a SLEEPmode, activated by pressing the button onthe control panel or remote control. SLEEPmode will change the fan speed to low andincrease the set temperature by 1°C eachhour for 2 hours. No further change willoccur after the 2nd hour.
Sleep Mode can only be used duringCooling mode, and will be cancelled if theMODE is changed, the cooler goes intostandby or the ‘Water Full’ alert occurs.
The air conditioner is fitted with a timerfunction. This can be set up to 24 hours inadvance. To use this function, the coolermust be plugged in and ready to operate.
With the air conditioner ON, press theTIMER button on the remote control orcontrol panel. The control panel display willflash and show the time setting. Press theTIMER button to increase the time in 1 hourincrements from 1 - 24 hrs. After 3 secondsthe display will revert to the SETtemperature.
When the air conditioner is OFF (but stillplugged in), repeat the above to set the ONtime. The air conditioner will start up withthe last settings used.
When the air conditioner is working,only the TIMER OFF can be set. When theair conditioner is off, only the TIMER ONcan be set.
Note!
How to cancel the timer
00To cancel the timer, set the time tousing the control panel or remote control.The TIMER indicator will stop glowing.
CP10-12CW1 Portable Refrigerated Air Conditioner8
Draining the Air Conditioner
To drain the air conditioner, place it over adrain point before unscrewing the cap andremoving the drain plug, as water will flowout as soon as the plug is removed.Remove the plug at the bottom rear of theappliance and allow the tank tocompletely drain (Fig 12B).
Note! Always replace the drain plugimmediately after draining.
Always disconnect the air conditioner from the electricity mains before cleaning ordraining.
To maximize the efficiency of the air conditioner, clean regularly.
Never operate the air conditioner without the filters.
Cleaning the housing
Cleaning the filters
Note!
Use a soft, damp cloth to wipe the body clean.Never use aggressive chemicals, spirits, detergents, chemically treated cloths, or othercleansing solutions. These substances could possibly damage the cabinet
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinseunder running water (no hotter than 40°C).Dry thoroughly before replacing.Take care to replace the filters back into the slots in the cooler.
.
Remove the filters from the top and bottom air inlet vents as shown (Fig 12A).
End of season storage:• Drain any water from the unit.
• Operate the unit in fan only mode for a few hours, to thoroughly dry the inside.
• Clean or change the filters.
• Replace in the original carton or cover for storage.
• Unplug and carefully store the power cord and plug end.
MAINTENANCE
B
12 A
Remove all filters (4 total)from the air conditionerand clean every 2 weeks.
SEELEY INTERNATIONAL – OWNER’S MANUAL 9
Never try to dismantle the air conditioner yourself.
Problem Check
The air conditioner does notrun.
Is the air conditioner plugged in?
Is there a power failure?
Is the "WATER FULL" error code flashing?Drain the tank as shown (Fig 12).
The air conditioner has littleeffect (firstly ensure that theroom being cooled is not toolarge for the stated capacityof the air conditioner).
Is there direct sunshine? Remember to closecurtains or blinds.
Are windows or doors open?
More people in the room will generate moreheat.
Is there something in the room producingexcessive heat?
Is the exhaust fitted correctly or obstructed?All exhaust air needs to be completelyremoved from the room.
The air conditioner is not ascool as it once was.
Are the filters dusty or dirty, restricting theairflow?
Is the air inlet or outlet blocked?
Is the room temperature below the settemperature?
The air conditioner is toonoisy.
Is the air conditioner positioned unevenly, soas to create vibration?
Is the floor beneath the air conditioneruneven?
It is possible that the overheat protection forthe compressor is on. Wait for it to reset.
Note: when changing between different modes(cooling to fan or dehumidifying mode etc) thecompressor will turn off. A 3 minute delay willoccur before the compressor will turn on again.
The compressor will not run.
In case of problems that cannot be fixed by using the above guide, or if serviceon your air conditioner is required, please contact your dealer or designatedservice agent.
TROUBLESHOOTING
Is the room temperature below the settemperature?
CP10-12CW1 Portable Refrigerated Air Conditioner10
SPECIFICATIONS
† Based on manufacturer's test results using the Air Enthalpy method
As a policy of continual product improvement, this manual, its contents and specifications are subject to change without notice.
WIRING DIAGRAM
SEELEY INTERNATIONALPORTABLE AIR CONDITIONER
330 / 370 / 830 330 / 370 / 830
Model(s)
Function
Cooling Capacity (Watts) †
Air Flow Volume (m / hr)3
Power Supply
Rated Input Power (Watts)
Fuse Type
Refrigerant Type / Charge (kg)
Water Ingress Protection Rating
Weight (kg)
Dimensions (mm)(width / depth / height)
CP10CW1 CP12CW1
Personal Cooling Personal Cooling
2900 (10,000 Btu/hr) 3500 (12,000 Btu/hr)
350 380
220-240V ~ 50Hz 220-240V ~ 50Hz
1110 1340
3.15A / 250V 3.15A / 250V
R410A / 0.47 R410A / 0.52
3.2 3.2
0.8 0.8
IP20 IP20
High Side Pressure - Maximum (MPa)
Low Side Pressure - Maximum (MPa)
26 26
SEELEY INTERNATIONAL – OWNER’S MANUAL 11
Never try to dismantle the air conditioner yourself.
Problem Check
The air conditioner does notrun.
Is the air conditioner plugged in?
Is there a power failure?
Is the "WATER FULL" error code flashing?Drain the tank as shown (Fig 12).
The air conditioner has littleeffect (firstly ensure that theroom being cooled is not toolarge for the stated capacityof the air conditioner).
Is there direct sunshine? Remember to closecurtains or blinds.
Are windows or doors open?
More people in the room will generate moreheat.
Is there something in the room producingexcessive heat?
Is the exhaust fitted correctly or obstructed?All exhaust air needs to be completelyremoved from the room.
The air conditioner is not ascool as it once was.
Are the filters dusty or dirty, restricting theairflow?
Is the air inlet or outlet blocked?
Is the room temperature below the settemperature?
The air conditioner is toonoisy.
Is the air conditioner positioned unevenly, soas to create vibration?
Is the floor beneath the air conditioneruneven?
It is possible that the overheat protection forthe compressor is on. Wait for it to reset.
Note: when changing between different modes(cooling to fan or dehumidifying mode etc) thecompressor will turn off. A 3 minute delay willoccur before the compressor will turn on again.
The compressor will not run.
In case of problems that cannot be fixed by using the above guide, or if serviceon your air conditioner is required, please contact your dealer or designatedservice agent.
TROUBLESHOOTING
Is the room temperature below the settemperature?
CP10-12CW1 Portable Refrigerated Air Conditioner10
SPECIFICATIONS
† Based on manufacturer's test results using the Air Enthalpy method
As a policy of continual product improvement, this manual, its contents and specifications are subject to change without notice.
WIRING DIAGRAM
SEELEY INTERNATIONALPORTABLE AIR CONDITIONER
330 / 370 / 830 330 / 370 / 830
Model(s)
Function
Cooling Capacity (Watts) †
Air Flow Volume (m / hr)3
Power Supply
Rated Input Power (Watts)
Fuse Type
Refrigerant Type / Charge (kg)
Water Ingress Protection Rating
Weight (kg)
Dimensions (mm)(width / depth / height)
CP10CW1 CP12CW1
Personal Cooling Personal Cooling
2900 (10,000 Btu/hr) 3500 (12,000 Btu/hr)
350 380
220-240V ~ 50Hz 220-240V ~ 50Hz
1110 1340
3.15A / 250V 3.15A / 250V
R410A / 0.47 R410A / 0.52
3.2 3.2
0.8 0.8
IP20 IP20
High Side Pressure - Maximum (MPa)
Low Side Pressure - Maximum (MPa)
26 26
SEELEY INTERNATIONAL – OWNER’S MANUAL 11
WARRANTY
In this warranty:
or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set outat the end of this warranty;
means you, the original end-user purchaser of the Goods;
means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;and
means the product, unit, appliance or equipment which was accompanied by this warranty andpurchased in Australia.
Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. Youare entitled to a replacement or refund for a major failure and for compensation for any otherreasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replacedif the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
In addition to any rights and remedies that You may have under the Australian Consumer Law or anyother law, subject to the terms of this warranty, We provide the following warranty:
1. If, during the first 24 months from the date of first retail purchase ( ), the Goodsupon examination prove defective by reason of improper workmanship or material, We will repairat our nearest service centre or replace (at our option), the product or any part thereof withoutcharge. Should we deem in our absolute discretion to replace the Goods, we may substitute anysimilar good even if it is not on our current price/equipment list. Further, Goods presented for repairmay be replaced by refurbished goods of the same type rather than being repaired. Refurbishedparts may be used to repair the Goods.
2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have notbeen used only for personal, domestic or household purposes or have not been operated andmaintained in accordance with the instructions in the Owner's Manual. The addition of any thirdparty device or the removal or the alteration of any of our components will void this warranty. Inaddition, the warranty granted under clause 1 does not apply to:
Consumable components such as filters,Adjustments necessary due to misuse of the cooler,Normal user maintenance,Setting of controls,Transit damage, orDamage caused by user misuse, tampering, or failure to observe the care and specialprovisions in the instructions.
3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the lawpermits, We will not be liable for any consequential loss suffered through, or resulting from, the nonoperation, or ineffective operation of the Goods. The warranty granted under clause 1 does notcover damage to the Goods or other loss resulting from acts of God.
4. We are not responsible in any way for any failure and/or inadequate performance of the Goodswhich arises from or is connected to the use in the Goods of non-genuine spare parts. We stronglyrecommend that only spare parts supplied or approved by us are used in the Goods.
We
You
Supplier
Goods
Warranty Period
······
5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other orgreater warranty than that given under this warranty. The benefits conferred by this warranty are infavour of You and any person deriving title to the Goods through or under such person and areintended to be separate from and additional to all other rights and remedies that they may have inlaw in respect of the Goods.
6.
t is your responsibility to cover all costs of returningthe Goods to the Supplier at the place of purchase.
If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under thewarranty granted under clause 1 You must return the Goods to the Supplier at the place ofpurchase together with the proof of purchase. I
WARRANTY cont.
7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warrantygranted under clause 1 You must:(a) either:
(I) contact us within the Warranty Period on: 1300 526 410;or(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;
and(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid
freight within the Warranty Period, together with (i) the legible and unmodified proof ofpurchase, which clearly indicates the name and address of the original retailer, the date andplace of purchase, the product name or other product serial number, and (ii) a copy of thecompleted Warranty Information below. (If you choose to return the Goods to us, there is anadditional requirement - they will also need to be accompanied by a covering letter whichstates your name and address and daytime telephone number, and the model and serialnumber of the goods.)
8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility tocover all forwarding and return freight costs incurred in sending the Goods to and from yournearest service centre or us.
9. This warranty is only valid and enforceable in Australia.
Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it isfair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic orhousehold use or consumption, your remedies associated with any failure or defect of the Product willbe limited to:
(a) the replacement of the Goods or the supply of equivalent goods;(b) the repair of the Goods;(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods; or(d) the payment of the cost of having the Goods repaired
and subject to the terms and conditions included in this warranty.
To ensure that service either pursuant to the above warranty or otherwise is readily available, we haveestablished in all States authorised service centres, which are available to deal with servicerequirements.
For further information about your nearest service centre and other enquiries please call our ServiceCentre on:
1300 526 410Please retain your receipt as proof of purchase. Every request for warranty must beaccompanied by proof of purchase.
:
Complete the following for your records:
: ...................................................................
...................................................................
Serial Number:
Model
Date purchased
Product
Purchased from
Convair SUPERCOOL
: CP10CW1 CP12CW1
: ....../....../......
1 1
Service DepartmentSeeley International Pty Ltd112 O'Sullivan Beach Road, Lonsdale, South Australia 5160Customer service centre in Australia: 1300 526 410Website: www.seeleyinternational.com
SEELEY INTERNATIONAL – OWNER’S MANUAL 13CP10-12CW1 Portable Refrigerated Air Conditioner12
WARRANTY
In this warranty:
or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set outat the end of this warranty;
means you, the original end-user purchaser of the Goods;
means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;and
means the product, unit, appliance or equipment which was accompanied by this warranty andpurchased in Australia.
Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. Youare entitled to a replacement or refund for a major failure and for compensation for any otherreasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replacedif the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
In addition to any rights and remedies that You may have under the Australian Consumer Law or anyother law, subject to the terms of this warranty, We provide the following warranty:
1. If, during the first 24 months from the date of first retail purchase ( ), the Goodsupon examination prove defective by reason of improper workmanship or material, We will repairat our nearest service centre or replace (at our option), the product or any part thereof withoutcharge. Should we deem in our absolute discretion to replace the Goods, we may substitute anysimilar good even if it is not on our current price/equipment list. Further, Goods presented for repairmay be replaced by refurbished goods of the same type rather than being repaired. Refurbishedparts may be used to repair the Goods.
2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have notbeen used only for personal, domestic or household purposes or have not been operated andmaintained in accordance with the instructions in the Owner's Manual. The addition of any thirdparty device or the removal or the alteration of any of our components will void this warranty. Inaddition, the warranty granted under clause 1 does not apply to:
Consumable components such as filters,Adjustments necessary due to misuse of the cooler,Normal user maintenance,Setting of controls,Transit damage, orDamage caused by user misuse, tampering, or failure to observe the care and specialprovisions in the instructions.
3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the lawpermits, We will not be liable for any consequential loss suffered through, or resulting from, the nonoperation, or ineffective operation of the Goods. The warranty granted under clause 1 does notcover damage to the Goods or other loss resulting from acts of God.
4. We are not responsible in any way for any failure and/or inadequate performance of the Goodswhich arises from or is connected to the use in the Goods of non-genuine spare parts. We stronglyrecommend that only spare parts supplied or approved by us are used in the Goods.
We
You
Supplier
Goods
Warranty Period
······
5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other orgreater warranty than that given under this warranty. The benefits conferred by this warranty are infavour of You and any person deriving title to the Goods through or under such person and areintended to be separate from and additional to all other rights and remedies that they may have inlaw in respect of the Goods.
6.
t is your responsibility to cover all costs of returningthe Goods to the Supplier at the place of purchase.
If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under thewarranty granted under clause 1 You must return the Goods to the Supplier at the place ofpurchase together with the proof of purchase. I
WARRANTY cont.
7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warrantygranted under clause 1 You must:(a) either:
(I) contact us within the Warranty Period on: 1300 526 410;or(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;
and(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid
freight within the Warranty Period, together with (i) the legible and unmodified proof ofpurchase, which clearly indicates the name and address of the original retailer, the date andplace of purchase, the product name or other product serial number, and (ii) a copy of thecompleted Warranty Information below. (If you choose to return the Goods to us, there is anadditional requirement - they will also need to be accompanied by a covering letter whichstates your name and address and daytime telephone number, and the model and serialnumber of the goods.)
8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility tocover all forwarding and return freight costs incurred in sending the Goods to and from yournearest service centre or us.
9. This warranty is only valid and enforceable in Australia.
Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it isfair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic orhousehold use or consumption, your remedies associated with any failure or defect of the Product willbe limited to:
(a) the replacement of the Goods or the supply of equivalent goods;(b) the repair of the Goods;(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods; or(d) the payment of the cost of having the Goods repaired
and subject to the terms and conditions included in this warranty.
To ensure that service either pursuant to the above warranty or otherwise is readily available, we haveestablished in all States authorised service centres, which are available to deal with servicerequirements.
For further information about your nearest service centre and other enquiries please call our ServiceCentre on:
1300 526 410Please retain your receipt as proof of purchase. Every request for warranty must beaccompanied by proof of purchase.
:
Complete the following for your records:
: ...................................................................
...................................................................
Serial Number:
Model
Date purchased
Product
Purchased from
Convair SUPERCOOL
: CP10CW1 CP12CW1
: ....../....../......
1 1
Service DepartmentSeeley International Pty Ltd112 O'Sullivan Beach Road, Lonsdale, South Australia 5160Customer service centre in Australia: 1300 526 410Website: www.seeleyinternational.com
SEELEY INTERNATIONAL – OWNER’S MANUAL 13CP10-12CW1 Portable Refrigerated Air Conditioner12
00231601-A convair.net.au AU 1205
Warranty Service
Australia 1-300-526-410seeleyinternational.com
It is the policy of Seeley International to introduce continualproduct improvement. Accordingly, specifications are
subject to change without notice. Please consult with yourdealer to confirm the specifications of the model selected.