Expert AnesthesiologyExpert AnesthesiologyMonitoring SystemMonitoring System
Team 2: Team 2: Timothy Morin, Nathan White, Kane Timothy Morin, Nathan White, Kane KilleleaKillelea
Sponsored by: Joseph H. Sponsored by: Joseph H. McIsaacMcIsaac and John D. and John D. EnderleEnderle
Sponsored By:Sponsored By:
Joseph Joseph McIsaacMcIsaacContact Information:Contact Information:
Joseph Joseph McIsaacMcIsaac, Ph.D., , Ph.D., Chief, Trauma Anesthesia Hartford Chief, Trauma Anesthesia Hartford
Hospital,Hospital,Suite JB300, Department of Suite JB300, Department of
AnesthesiologyAnesthesiology80 Seymour 80 Seymour St.HartfordSt.Hartford, CT 06102, CT 06102
(860) 545(860) 545--2117 2117
[email protected]@harthosp.org
John John EnderleEnderleContact Information:Contact Information:
EditorEditor--inin--Chief, EMB MagazineChief, EMB MagazineBiomedical Engineering Book Biomedical Engineering Book Series Editor for Morgan and Series Editor for Morgan and
Claypool PublishersClaypool PublishersProgram Director & Professor for Program Director & Professor for
Biomedical Engineering Biomedical Engineering University of ConnecticutUniversity of Connecticut
BronwellBronwell Building, Room 217CBuilding, Room 217C260 Glenbrook Road260 Glenbrook Road
Storrs, Connecticut 06269Storrs, Connecticut 06269--22472247(860) 486(860) 486--55215521
[email protected]@bme.uconn.edu
BackgroundBackground
•• Ideal Product Application: Ideal Product Application: •• Development of an anesthesiology system that provides Development of an anesthesiology system that provides
the anesthesiologist with an optimal method for the anesthesiologist with an optimal method for determining drug dosages throughout a surgical determining drug dosages throughout a surgical procedure. procedure.
•• The monitor will incorporate a patientThe monitor will incorporate a patient’’s personal s personal information.information.
•• The BIS monitoring system will provide the data for The BIS monitoring system will provide the data for determining the patientdetermining the patient’’s level of consciousness.s level of consciousness.
•• The GEThe GE--Marquette system will receive the output from Marquette system will receive the output from our device and apply the correct dosage.our device and apply the correct dosage.
Project GoalsProject Goals
•• Use Use LabVIEWLabVIEW to Create:to Create:–– A clear visual display of data and dosage.A clear visual display of data and dosage.–– Use Patient information to find a sufficient anesthesia Use Patient information to find a sufficient anesthesia
dosage using:dosage using:–– prior resistance, acute and chronic disease states, age, prior resistance, acute and chronic disease states, age,
weight, gender, exercise tolerance, medication usage, and weight, gender, exercise tolerance, medication usage, and habits such as smoking, drug and alcohol use.habits such as smoking, drug and alcohol use.
–– Primary Functions:Primary Functions:•• Import BIS monitor and GEImport BIS monitor and GE--Marquette, then apply the Marquette, then apply the
patients information to the data to determine a proper patients information to the data to determine a proper dosage. dosage.
Project Goals (cont.)Project Goals (cont.)
•• The program should be reliable and easily The program should be reliable and easily understood.understood.
•• The settings should be easily manipulated.The settings should be easily manipulated.•• Front panel should display:Front panel should display:
–– Clear graphs with:Clear graphs with:•• Corresponding numerical valuesCorresponding numerical values•• Appropriate clear labelsAppropriate clear labels
–– Clean and purposeful appearanceClean and purposeful appearance
Project Goals (cont.)Project Goals (cont.)
•• Real Time ProcessingReal Time Processing–– Simply put, itSimply put, it’’s processes data on a first in s processes data on a first in
first out basis. first out basis. –– Optimization of the Software and hardware.Optimization of the Software and hardware.
•• Provides minimal processing time Provides minimal processing time •• Allows the device to display the most current Allows the device to display the most current
patient status.patient status.
Patents ResultsPatents Results
•• Possible patent infringementPossible patent infringement–– Vital signs monitoring system (1987)Vital signs monitoring system (1987)–– Anesthesia machine with gas delivery system control and a Anesthesia machine with gas delivery system control and a
patient monitoring system (2002)patient monitoring system (2002)–– Operative and postOperative and post--operative patient monitoring. Focusing on operative patient monitoring. Focusing on
the relative power of the theta wave (2000)the relative power of the theta wave (2000)
•• Most patents deal with signal acquisitionMost patents deal with signal acquisition–– Our device is the optimizing the current method of determining Our device is the optimizing the current method of determining
dosages and providing an input to the GE Marquette delivery dosages and providing an input to the GE Marquette delivery system. system.
Anesthesia MonitorsAnesthesia Monitors
•• GEGE--Marquette Anesthesia Delivery SystemMarquette Anesthesia Delivery System–– Anesthesia delivery and patient monitoringAnesthesia delivery and patient monitoring
•• Aspect Medical BISAspect Medical BISTMTM EEG monitorEEG monitor–– Monitors the patientMonitors the patient’’s EEG signals EEG signal
BIS VistaBIS Vista
Advantages:Advantages:•• Clear Clear •• AccurateAccurate•• AlarmAlarm•• Uses EEG to Uses EEG to
determine level of determine level of consciousnessconsciousness
BISBISTMTM Monitoring system continued.Monitoring system continued.
•• Serial port: ASerial port: A--20002000–– Asynchronous Serial CommunicationAsynchronous Serial Communication–– DBDB--9 female adapter9 female adapter–– Pin connections: 2,3,5Pin connections: 2,3,5
GEGE--Marquette Delivery SystemMarquette Delivery System
•• Clear Clear •• Accurate dosagesAccurate dosages•• Ability for multiple Ability for multiple
anesthesia anesthesia medicationsmedications
•• Dosage recordsDosage records•• Can import data from Can import data from
other devices and other devices and display.display.
Expert Anesthesia InterfaceExpert Anesthesia Interface
The IdeaThe Idea
•• Importing of consciousness level from the Importing of consciousness level from the Aspect BIS Anesthesia Monitor.Aspect BIS Anesthesia Monitor.
•• Use patients prior information to recommend a Use patients prior information to recommend a dosage for the patient.dosage for the patient.
•• Time stamp will be done as the information is Time stamp will be done as the information is received and for when the dosage is applied.received and for when the dosage is applied.
•• Output the data to the GEOutput the data to the GE--Marquette to supply Marquette to supply the dosage to the patient.the dosage to the patient.
PatientPatient’’s Prior Informations Prior Information
To determine a proper To determine a proper dosage for a patient dosage for a patient a few aspects must a few aspects must be considered and be considered and calculated.calculated.
•• An example of An example of Physical condition Physical condition dosage dosage adjustments.adjustments.
PatientPatient’’s Prior Informations Prior Information
•• Example of Sex Example of Sex diagnostic dosage diagnostic dosage changes.changes.
•• A graphical display of A graphical display of how the dosages will how the dosages will change within ranges.change within ranges.
BlackfinBlackfin
•• BlackfinBlackfin will be able to will be able to run the run the labviewlabviewprogram designed program designed and display the and display the relevant information.relevant information.
•• LCD, Buttons, Aspect LCD, Buttons, Aspect BIS monitor, and GEBIS monitor, and GE--Marquette will all Marquette will all attach to the attach to the balckfinbalckfinfor integration.for integration.
Material RequirementsMaterial Requirements
•• CaseCase–– ABS plasticABS plastic–– Sized so there is Sized so there is
minimal extra space minimal extra space insideinside
Material Requirements (cont.)Material Requirements (cont.)
•• Cooling FanCooling Fan–– Mounted in the back of Mounted in the back of
the casethe case–– Reduce internal Reduce internal
temperature of the temperature of the devicedevice
Material Requirements (cont.)Material Requirements (cont.)
•• LCD DisplayLCD Display–– 10.3910.39”” diagonaldiagonal
Material Requirements (cont.)Material Requirements (cont.)
•• ButtonsButtons–– Surface mount tactile Surface mount tactile
switchesswitches
BudgetBudgetPart Cost Shipping and Handling
Power Source – Double-Fused Three Function Power Entry Module $31.34 Unknown
Power Source cord $4.96 Unknown
UFO Cube Computer Case $299.99 Unknown
LCD6VGA 8” Open Frame TFT $599.99 $49.99
ADI Blackfin Processor $23.63 Unknown
Ultra Copper Core Cooling Fan $14.13 Unknown
(ON)-OFF SPST Momentary $2.50 $1
RS422 Serial Cables $7.50 $1.75
Resistor- 226-1058-ND $5 each Unknown
Capacitor -338-1364-ND $3 each Unknown
Op-Amplifiers- 296010025-2-ND $5.10 each Unknown
Budget (cont.)Budget (cont.)
•• Testing supplyTesting supply’’ss•• Sensors for connecting Sensors for connecting LabVIEWLabVIEW to the to the
subjects.subjects.
ConclusionConclusion
•• Expert Anesthesiology Monitoring SystemExpert Anesthesiology Monitoring System–– This design should help to maintain the amnesia, This design should help to maintain the amnesia,
analgesia, and immobility of the patient with accuracyanalgesia, and immobility of the patient with accuracy–– Custom designCustom design–– Clear and AccurateClear and Accurate–– Easy and FunctionalEasy and Functional
Utilizing biomedical engineering principles to enhance Utilizing biomedical engineering principles to enhance the abilities and analysis skills of the anesthesiologist the abilities and analysis skills of the anesthesiologist in the operating room that will give a new level of in the operating room that will give a new level of judgment capability.judgment capability.
AcknowledgementsAcknowledgements
We would like to Thank:We would like to Thank:
•• John John EnderleEnderle•• William William PruehsnerPruehsner•• Joseph Joseph McIsaacMcIsaac•• AnastasiosAnastasios MaurudisMaurudis•• David David KaputaKaputa
Thank You!Thank You!
Any Questions?Any Questions?