RESIDENTIAL ROOFING
Espan 340™ / 470™
0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
00 / 00 COVER SHEET01 / 24 ROOF RIDGE01A / 24 RIDGE FLASHING ALTERNATIVE OPTION02 / 24 SAWTOOTH RIDGE03 / 24 SAWTOOTH EAVE04 / 24 ROOF VALLEY05 / 24 ROOF - CHANGE PITCH06 / 24 EAVE WITH METALLINE FASCIA07 / 24 EAVE WITH INTERNAL GUTTER BRACKET08 / 24 EAVE WITH SNOW STRAP09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET10A / 24 EAVE FLASHING ALTERNATIVE OPTION11 / 24 BARGE WITH PROFILED CLADDING12 / 24 BARGE OVERHANG12A / 24 BARGE FLASHING ALTERNATIVE OPTIONS13 / 24 PARAPET WITH TRANSVERSE APRON14 / 24 TRANSVERSE APRON14A / 24 TRANSVERSE APRON ALTERNATIVE OPTION15 / 24 PARALLEL APRON16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION17 / 24 OVER 85mm DIAMETER PIPE PENETRATION18 / 24 3D RIDGE TO BARGE JUCTION19 / 24 3D DUTCH GABLE20 / 24 3D APRON21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D CHIMNEY PENETRATION23 / 24 3D RIDGE/BARGE FLASHINGS24 / 24 3D DUTCH GABLE FLASHINGS
DETAIL LIST
* ESPAN™ 340 MIN. ROOF PITCH = 3°
PRE-FINISHED RIDGE CAP FLASHING
STOPENDS TO ROOF CLADDING
ROOF FRAMING
PURLIN
METALCRAFT ESPAN™ROOFING
PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mmSCREWS
BUILDING PAPERSHOWN DASHED
15.0
0°
X
NOTCHED EDGE OVERESPAN™ RIBS. REFERTO SHEET NO. 01A/24FOR ALTERNATIVEOPTION.
5mm
GAP 5m
m G
AP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
PRE-FINISHED RIDGE CAP FLASHING
STOPENDS TO ROOF CLADDING
ROOF FRAMING
PURLIN
METALCRAFTESPAN™ROOFING
METALCRAFT ESPAN™CLIP SYSTEM WITH 12Gx 35mm SCREWS
BUILDING PAPERSHOWN DASHED
15.0
0°
PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
PRE-FINISHED 'T' SHAPEFLASHING. NOTCHEDOVER ESPAN™ RIBS
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°PRE-FINISHED
SAWTOOTH RIDGE CAPFLASHING.
STOPENDS TO ROOF CLADDING
BUILDING PAPER SHOWNDASHED
PURLIN
PRE-FINISHED 8g WAFER-TEKSCREW BEDDED IN SILICONE
METALCRAFT ESPAN™CLIP SYSTEM WITH 12Gx 35mm SCREWS
ROOF OR WALLFRAMING
TIMBER PACKER
FASCIA BOARD
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™ ROOFING
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
15.0
0°
Z
X
5mm
GAP
HEMMED EDGE
NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO.01A/24 FOR ALTERNATIVE OPTION.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER FASCIA
SOFFIT LINING
METALCRAFT ESPAN™ ROOFING
BUILDING PAPER SHOWN DASHED
PURLIN
PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING
METALCRAFT ESPAN™CLIP SYSTEM WITH12G x 35mm SCREWS
ROOF FRAMING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
15.0
0°X
Z
PRE-FINISHED 8g WAFER-TEKSCREW BEDDED IN SILICONE
5mm
GAP
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
HEMMED EDGE
STOPENDS TO ROOFCLADDING
NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO.01A/24 FOR ALTERNATIVE OPTION.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
ROOF FRAMING
PURLIN
METALCRAFT ESPAN™ROOFING
METALCRAFT ESPAN™CLIP SYSTEM WITH 12G x35mm SCREWS
BUILDING PAPER CONTINUOUSUNDER GUTTER IF COPPER BASEDTREATMENTS ARE USED
VALLEY BOARD
PREFINISHED VALLEY GUTTER
MIN
. 50m
m
CC
B : CLEARANCE BETWEEN ROOFING
A : OVERALL VALLEY GUTTER WIDTH
MIN
. 20mm
SITUATION 1
MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°
MIN. 250mm
MIN. 50mm
MIN. 80mm
SITUATION 2
MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°
160mm - 249mm
MIN. 40mm
MIN. 60mm
A
B
C
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FORFURTHER INFORMATION.
* ROOF PITCH FOR VALLEYS AS PER E2.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
ROOF VALLEY
04 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
PURLIN
METALCRAFT ESPAN™ROOFING
METALCRAFT ESPAN™CLIP SYSTEM WITH 12G x35mm SCREWS
PURLIN
ROOF FRAMING
PRE-FINISHED CHANGE OF ROOFPITCH FLASHING
BUILDING PAPERCONTINUOUS OVERFLASHING SHOWN DASHED
BUILDING PAPER CONTINUOUSUNDER FLASHING SHOWN DASHED
45.0
0°10
.00°
MIN. 250mm
CLEARANCE
MIN. 10mm
X
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
STST OR GALV. FLAT HEADNAIL FOR FLASHING
NOTCHED EDGE OVERESPAN™ RIBS. REFER TOSHEET NO.01A/24 FORALTERNATIVE OPTION.
5mm
GAP
PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™ ROOFING.STOPENDS TO ROOF CLADDING
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
STST OR GALV. FLAT HEAD NAIL
METALCRAFT ESPAN™ROOFING
PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.
BUILDING PAPER SHOWNDASHED
METALLINE™ FASCIA
FASCIA BRACKET
SOFFIT LINING
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mmSCREWS
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTEROVERSTRAP
TIMBER ROOF FRAMING
15.00°
OVE
RLA
P
MIN
. 35m
m
OR AS REQU
IREDMIN. 5
0mm
MIN. 125 mm
SPRING CLIP
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH METALLINE FASCIA
06 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER FASCIA
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTERINTERNAL BRACKET
15.00°
SOFFIT LINING
TIMBER ROOF FRAMING
METALCRAFT ESPAN™ROOFING
BUILDING PAPER SHOWNDASHED
OR AS REQU
IREDMIN. 5
0mm
MIN. 125 mm
OVE
RLA
P
MIN
. 35m
mTIMBER PURLIN
PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH INTERNAL GUTTER BRACKET
07 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER FASCIA
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTERINTERNAL BRACKET
15.00°
SOFFIT LINING
TIMBER ROOF FRAMING
METALCRAFT ESPAN™ROOFING
BUILDING PAPER SHOWNDASHED
OVE
RLA
P
MIN
. 35m
mTIMBER PURLIN
REFER TO SHEET NO.10A/24FOR ALTERNATIVE FLASHINGOPTION.
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
STST OR GALV. FLAT HEAD NAIL FORFLASHING
OR AS REQU
IREDMIN. 5
0mm
MIN. 125 mm
SNOW STRAP AS REQUIRED
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH SNOW STRAP
08 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER PACKER
FASCIA BOARD
TIMBER PACKER
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
15.00°
METALCRAFT ESPAN™ROOFING
BUILDING PAPER SHOWNDASHED
OVE
RLA
P
MIN
. 35m
mTIMBER PURLIN
PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
STST OR GALV. FLAT HEAD NAIL FORFLASHING
OR AS REQU
IREDMIN. 5
0mm
MIN. 125 mm
QUARTER ROUND GUTTER
QUARTER ROUND GUTTERINTERNAL BRACKET
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH INTERNAL GUTTER BRACKET
09 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER PURLIN
PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.
QUARTER ROUND GUTTER
QUARTER ROUND GUTTEREXTERNAL BRACKET METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
15.00°
METALCRAFT ESPAN™ROOFING
BUILDING PAPER SHOWNDASHED
TIMBER PACKER
FASCIA BOARD
TIMBER PACKER
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
OVE
RLA
P
MIN
. 35m
m
STST OR GALV. FLAT HEAD NAIL FORFLASHING
OR AS REQU
IREDMIN. 5
0mm
MIN. 125 mm
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH EXTERNAL GUTTER BRACKET
10 / 242014
* ESPAN™ 340 MIN. ROOF PITCH = 3°
TIMBER FASCIA
BOX GUTTER 125 WITHEXTERNAL BRACKET
15.00°
SOFFIT LINING
TIMBER ROOF FRAMING
METALCRAFT ESPAN™ROOFING BUILDING PAPER SHOWNDASHED
MIN. 125mm
STST OR GALV. FLAT HEADNAIL FOR FLASHING
PRE-FINISHED EAVE FLASHINGALTERNATIVE OPTION
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
TIMBER PURLIN
PRE-FINISHED 8g WAFER-TEK SCREW
OVE
RLA
P
MIN
. 35m
m
OR AS REQU
IREDMIN. 5
0mm
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE FLASHING ALTERNATIVE OPTION
10A / 242014
TIMBER PACKER
BARGE BOARD
BUILDING PAPERSHOWN DASHED
PURLIN
WEATHERBOARDSON CAVITY
BUILDING PAPER SHOWNDASHED
PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER
ROOF FRAMING
TIMBER PACKER
PRE-FINISHED BARGEFLASHING BRACKETSFIXED WITH PRE-FINISHED COUNTERSUNK 8g WAFER-TEKSCREW
Z
METALCRAFT ESPAN™ ROOFING
PRE-FINISHED BARGE FLASHING WITH SECRETGUTTER. REFER SHEET NO.12A/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS
PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
5mm
GAP
FOR SET OUT TO BE SYMMETRICAL
THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 70mmZ
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
METALCRAFT ESPAN™ ROOFING
FLY RAFTER
PRE-FINISHED BARGEFLASHING BRACKETS FIXEDWITH PRE-FINISHEDCOUNTER SUNK 8g WAFER-TEK SCREW
BARGE BOARD
BUILDING PAPER SHOWNDASHED
PURLIN
SOFFIT LINING
PRE-FINISHED BARGE FLASHING WITH SECRETGUTTER. REFER SHEET NO.12A/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS
PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER
5mm
GAP
Z
PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
FOR SET OUT TO BE SYMMETRICAL
THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 70mmZ
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
5mm
GAP
25 mm
METALCRAFT ESPAN™ ROOFING
FLY RAFTER
PRE-FINISHED BARGEFLASHING BRACKETS FIXEDWITH PRE-FINISHED COUNTERSUNK 8g WAFER-TEK SCREW
BARGE BOARD
BUILDING PAPER SHOWN DASHED
PURLIN
SOFFIT LINING
PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER
PRE-FINISHED POP RIVET BEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
Z
FOR SET OUT TO BE SYMMETRICAL
THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE
PRE-FINISHED BARGE FLASHING WITHSECRET GUTTER. REFER SHEET NO.12/24 &12B/24 FOR ALTERNATIVE FLASHING OPTIONS
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 70mmZ
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
TIMBER PACKER
FASCIA BOARD
WEATHER-BOARDON CAVITY
BUILDING PAPERSHOWN DASHED
PRE-FINISHED PARAPETCAP FLASHING
TIMBER PACKER
BUILDING PAPER TO PROVIDESEPARATION OF METAL CAPPINGAND TIMBER SHOWN DASHED
PURLIN
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™ ROOFING
BUILDING PAPER SHOWN DASHED
15.0
0°WALL FRAMING ROOF FRAMING
TIMBER NOG FORFIXING APRONFLASHING
CONTINUOUS TIMBER PACKING
MIN
. 5.0
0°
Z
GN
L
STST OR GALV.FLAT HEAD NAILFOR FLASHING
PRE-FINISHEDSELFDRILLING/TAPPINGSCREW WITHRUBBER WASHER
PRE-FINISHED 8gWAFER-TEK SCREWBEDDED INSILICONE
5mm
GAP
PRE-FINISHED APRON FLASHING.NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO. 01A/24FOR ALTERNATIVE OPTION.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 70mm
G
N
L
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
15.0
0°
GN
L
5mm
GAP
STOPENDS TO ROOF CLADDING
ROOF FRAMING
BUILDING PAPER SHOWNDASHED
PVC CAVITY CLOSER
WALL CLADDING ON CAVITY
CANT STRIP PACKER
NOG FOR FIXING APRONFLASHING
STST OR GALV. FLAT HEADNAIL FOR FLASHING
METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 35mm SCREWS METALCRAFT ESPAN™ ROOFING
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PRE-FINISHED APRONFLASHING
EXTRA BUILDING PAPER OVERFLASHING SHOWN DASHED
PURLIN NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO. 14A/24FOR ALTERNATIVE OPTION.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
G
N
L
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
* ESPAN™ 340 MIN. ROOF PITCH = 3°
15.0
0°
GN
STOPENDS TO ROOF CLADDING
ROOF FRAMING
BUILDING PAPER SHOWNDASHED
PVC CAVITY CLOSER
WALL CLADDING ON CAVITY
CANT STRIP PACKER
NOG FOR FIXING APRONFLASHING
STST OR GALV. FLAT HEADNAIL FOR FLASHING
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS
METALCRAFT ESPAN™ ROOFING
PRE-FINISHED SECONDARYFLASHING NOTCHED OVERESPAN™ RIBS
PRE-FINISHED APRON FLASHINGALTERNATIVE OPTION
EXTRA BUILDING PAPER OVERFLASHING SHOWN DASHED
PURLIN
PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
L
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
G
N
L
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
PRE-FINISHED 12gx55mm WAFER-TEK WITH WASHER
PRE-FINISHED APRON SECRETGUTTER FLASHING PRE-FINISHED POP RIVET
BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PURLIN
GN
PRE-FINISHEDAPRON FLASHING
WEATHERBOARDS WALLCLADDING ON CAVITY
CANT STRIP PACKER
BUILDING PAPER OVERFLASHING SHOWN DASHED
STST OR GALV. FLATHEAD NAIL FORFLASHING
NOG FOR FIXINGAPRON FLASHING
PVC CAVITY CLOSER
METALCRAFT ESPAN™ROOFING
HEM PRE-FINISHEDFLASHING TO EDGE
BUILDING PAPER SHOWNDASHED
5mm
GAP
ROOF FRAMING
REFER SHEET NO.12B/24 FORALTERNATIVE FLASHING OPTIONS
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
G
N
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH
METALCRAFT ESPAN™ ROOFING
EPDM FLEXIBLE CONE SLEEVE
MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.
TIMBER PURLIN
BUILDING PAPER SHOWN DASHED
THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°and MAX. 45°- PIPE DIAMETER MAX. 85mm
METALCRAFT ESPAN™ ROOFING
PIPE (PIPE DIAMETER ≤ 85mm)
EPDM FLEXIBLE CONE SLEEVE
BUILDING PAPER SHOWN DASHED
MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.
TIMBER PURLIN
15.00°
* MIN. 10° FOR PIPE PENETRATION
ROOF FRAMING
ROOF FRAMING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 5
MAX. 85mm DIAMETER PIPE PENETRATION
16 / 242014
PRE-FINISHED SOAKER FLASHING UNDERPRE-FINISHED ROOF RIDGE FLASHING.REFER SHEET NO.12/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS.
PIPE (85mm > PIPE DIAMETER ≤ 500mm)
EPDM FLEXIBLE CONE SLEEVE
MALLEABLE FLANGE, SCREW OR RIVET FIXED,AND SEALED TO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN. REFER TO MRMCODE OF PRACTICE VERSION 2 2/2012.
PRE-FINISHED SOAKER FLASHING WITHESPAN SECRETE GUTTER FLASHING.REFER SHEET NO.12,12A&12B/24 FORALTERNATIVE FLASHING OPTIONS.
PURLIN
BUILDING PAPER SHOWN DASHED
THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°- PIPE DIAMETER OVER 85mm AND MAX. 500mm- PIPE TO BE POSITIONED AS CLOSE TO ROOF RIDGEAS POSSIBLE
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PURLIN
ROOF FRAMING
ROOF FRAMING
PRE-FINISHEDROOF RIDGEFLASHING
METALCRAFTESPAN™ROOFING
X
L
5mm
GAP
5mm
GAP
NOGS BETWEEN PURLINS FOR PENETRATION
15.00°* MIN. 10° FOR PIPE PENETRATION
REFER TO SHEET NO. 14/24 TRANSVERSE APRON
REFER TO SHEET NO. 16/24 PARALLEL APRON
REFER TO SHEET NO. 01/24 ROOF RIDGE
L
M
X
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 5
OVER 85mm DIAMETER PIPE PENETRATION
17 / 242014
PRE-FINISHED RIDGE CAPFLASHING
METALCRAFT ESPAN™ROOFING
METALCRAFT ESPAN™ROOFING BARGE FLASHINGWITH SECRET GUTTER. REFERTO SHEET NO.12/24
PURLIN
ROOF FRAMING
FASCIA BOARD
WALL CLADDING ON CAVITY
WALL FRAMING
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D RIDGE TO BARGE JUCTION
18 / 242014
PRE-FINISHED RIDGE FLASHING
METALCRAFT ESPAN™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG
PRE-FINISHED BARGE FLASHING
PRE-FINISHED APRONFLASHING
PRE-FINISHED HIP FLASHING
GUTTER
FASCIA BOARD
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.
WALL CLADDING ON CAVITY
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D DUTCH GABLE
19 / 242014
GUTTER
METALCRAFT ESPAN™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG
WALL CLADDING ON CAVITY
PRE-FINISHED APRON FLASHINGWITH SECRET GUTTER. REFERTO SHEET NO.15/24
PRE-FINISHED APRON DIVERTER
WALL CLADDING ON CAVITY
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.
FASCIA BOARD
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D APRON
20 / 242014
PRE-FINISHED SOAKER FLASHING
EPDM FLEXIBLE CONE SLEEVE
MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREWFIXINGS. FITTED ON 45° ANGLE INPLAN. REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.
PRE-FINISHED ROOF RIDGEFLASHING
PIPE(85mm < PIPE DIAMETER ≤ 500mm)
METALCRAFT ESPAN™ ROOFING
METALCRAFT ESPAN™ ROOFINGBARGE FLASHING WITH SECRETGUTTER. REFER TO SHEETNO.12/24
PRE-FINISHED SOAKER FLASHINGUNDER PRE-FINISHED ROOF RIDGEFLASHING
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D OVER 85mm DIAMETER PIPE PENETRATION
21 / 242014
METALCRAFT ESPAN™ROOFING TURN DOWN INTOGUTTER
PRE-FINISHED APRONSECRET GUTTER FLASHING.REFER TO SHEET NO.15/24
WALL CLADDING ON CAVITY
PREFINISHED VALLEY GUTTER
PURLINPRE-FINISHED SOAKERFLASHING
VALLEY BOARD
ROOF FRAMING
MIN
. 110
mm
UPS
TAN
D
MIN. 110mm UPSTANDPRE-FINISHED 1.6mmALUMINIUM WELDEDSOAKER FLASHING
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FORFURTHER INFORMATION ON FLASHING COVER WIDTHS.
DIVERTER FLASHING ONUPPER SIDE OF CHIMNEY
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D CHIMNEY PENETRATION
22 / 242014
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D RIDGE/BARGE FLASHINGS
23 / 242014
OPTION 1
RIDGE CAPFLASHING
ADDITIONALSADDLEFLASHING
BARGEFLASHING
RIDGE CAPFLASHING
ADDITIONALSADDLEFLASHING
BARGEFLASHING
OPTION 2
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.
(3) PRE-FINISHEDSADDLE FLASHING
(4) PRE-FINISHEDBARGE FLASHING
(2) PRE-FINISHEDAPRON FLASHING
(1) PRE-FINISHED HIPFLASHING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGEspan 340™ / 470™
RREP ScaleDate Sheet
3D DUTCH GABLE FLASHINGS
24 / 242014
* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.
Top Related