WPS6 / WPS6S
Features:
EP Series
M: Mechanical speed governor, E/ECU: Electronic speed governor;NA: Naturally aspirated, TC: Turbocharged, TCA: Turbocharged and air-air aftercooled. TCW: Water-cooled Turbocharged;The weights are approximate and without fuel.
Also available in the following voltages: 415/240V-380/220V-220/127V-200/115V; ESP: Standby Power Standby duty, operation under variable load, without over load;PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours;The data is only for your reference but not for use of sales.
Ratings at 0.8 power factor.
Generating Set Model Prime Standby
WPS6/S 5.8kVA/4.7kW 6.4kVA/5.1kW
Output Ratings
Ratings and Performance Data Dimensions and Weights
Dry = With Lube Oil Wet = With Lube Oil and Coolant
Length (L)mm (in)
Width (W)mm (in)
Height (H)mm (in)
Drykg (lb)
Wetkg (lb)
GeneratingSet Model
WPS6
WPS6S
1250 600 1000 300
1800 928 1250 600
Prime
Standby
WPS6
WPS6S
WPS6
WPS6S
Engine Make & Model:
Alternator Brand:
Alternator Model:
Frequency & Phase:
Control System:
Circuit Breaker Type:
Noise Level@7m:
Engine Speed: RPM
Structure Type:
Fuel Tank Capacity: L
(100% Load)Fuel Consumption: l/hr
/
/
• Excitation system: self-excited (AREP and PMG are optional)
• ATS (automatic transfer switch) receptacle
• Lockable battery isolator switch
• Stainless galvanized zinc plates with strong
corrosion resistance
• Vibration isolators between the engine/alternator
and base frame
• Integrated wiring design
• Base fuel tank for at least 8 hours running
• Equipped with an industrial muffler
• Engine oil pump
• 50℃ radiator
• Top lifting and steel base frame with forklift holes
• Drainage for fuel tank
• Complete protection functions and safety labels
• IP54 (soundproof sets), IP56 (control system)
• Water jacket preheater, oil heater and double air
cleaner, etc. are available.
403D-07G
ECP28-2VS/4
MECC
PLC-920 / PLC-7420
/
/
50Hz & 3PH
1500
D
RS
60
80
/
/
WPS6 / WPS6SEP Series
Engine model: 403D-07G
Powered by your needsThe Perkins 400D range has been developed in consultation with ourmarketplace. This 0.7 litre,3 cylinder engine is one of the smallest engines offeredby Perkins, however, this ultra-compact, lightweight power unit still maintains allthe customer benefits experienced from this exciting Product range.
Compact, Clean, Efficient PowerDesign features on the 400D range of ElectropaKs ensures clean rapid starting inall conditions whilst delivering impressive performance with low operating costs ina small, efficient package size.
Lower Operating CostsApproved for operation on biodiesel * concentrations of up to 20%.Oil and filter changes are 500 hours, dependent on load factor.Engine durability and reliability, the warranty offering and ease of installationcombine to drive down the cost of ownership.
Long-term Power Solution
The 400D range of ElectropaKs has been designed to fully comply with stringent EU and EPA emissions regulations, providing an emissions compliant power solution for the future.
Fuel SystemMechanically governed cassette type fuel injection pumpSplit element fuel filter
Lubrication SystemWet steel sump with filler and dipstickSpin-on full-flow lub oil filter
Cooling SystemThermostatically-controlled system with belt driven coolant pump and pusher fan
Electrical Equipment12 volt starter motor and 12 volt 14 amp alternator with DC outputOil pressure and coolant temperature switches12 volt shut-off solenoid energised to runGlow plug cold start aid and heater/starter switch
Flywheel and Housing1500/1800 rev/minHigh inertia flywheel to SAE J620 Size 6½ HeavyFlywheel housing SAE 5 Long3000 rev/minHigh inertia flywheel to SAE J620 Size 6½ LightFlywheel housing SAE 5 Short
MountingsFront and rear engine mounting brackets
Optional EquipmentWorkshop manualParts book
Option GroupsA selection of optional items is available to enable you to prepare a specification precisely matched to your needs.
Emissions Statement
Variable Speed: Industrial and IOPU engines: Certified against therequirements of EU Stage IIIB (Directives 97/68/EC, as last amended, and 2005/26/EC, as last amended); and US EPA Tier 4 Interim (40CFR Parts 1039. NOTE Tier 4 Final will start in 2013 model year for 19-56 kW engines).Constant Speed Engines for use in Industrial, IOPU and ElectropaK applications: Certified against the requirements of EU Stage IIIA (Directives 97/68/EC, as last amended, for mobile applications); and US EPA Tier 4 Interim (40 CFR Parts 60 for stationary applications and 40CFR Part 1039 for mobile applications).
General DataNumber of cylinders 3Cylinder arrangement Vertical in-lineCycle 4 strokeAspiration Naturally aspiratedCombustion system Indirect in jectionCompression ratio 23.5:1Bore and Stroke 67x72mmDisplacement 0.761 litresDirection of rotation Anti-clockwise
viewed on flywheelCooling system Water cooledTotal coolant capacity 2.6 litresTotal lubrication 3.05 litressystem capacityLength 480 mmWidth 371 mmHeight 528 mmTotal weight (dry) 71 kg
FuelConsumption(gross)
Engine Speed1800 rev/min 3000 rev/min
g/kW hl/hr g/kW hl/hr
100%primepower 258 1.7 271 2.9
WPS6 / WPS6SEP Series
Alternator model: ECP28-2VS/4
Electrical CharacteristicsFrequencyVoltage (series star)Rated power class H
Rated power class F
Regulation with Insulation classExecution Stator windingRotorEfficiencies class H(see graph. for details)
Reactances (f. l.cl. F)
Short Circuit RatioTime Constants
Short Circuit Current CapacityExcitation at no loadExcitation at full loadOverload (long-term)Overload per 20 sec.Stator Winding Resistance (20°C) Rotor Winding Resistance (20°C)Exciter Resistance (20 °C)Heat dissipation at f.l.cl.HTelephone InterferenceRadio interferenceWaveform Distors.(THD) at f. loadWaveform Distors.(THD) at no load
Mechanical characteristicsProtectionDE bearingNDE bearingWeight of wound stator assemblyWeight of wound rotor assemblyWeight of complete generatorMaximun overspeedUnbalanced magnetic pull at f.l.cl.F
Xd Xd' Xd" Xq Xq' Xq"
2
X0
KccTd'Td"Tdo'α
%Amp.Amp.
%%ΩΩΩW
LL/LN %LL/LN %
kgkgkg
rpmkN/mm
HzV
kVAkWkVAkW
DSR
4/43/4 2/4 1/4
%%%%
0605
380 400 415 440 415 440 460 480
11 11 11 / 11,5 12,4 13,2 13,2
8,8 8,8 8,8 / 9 9,9 10,6 10,6
10 10 10 / 10,5 11 12 12
8 8 8 / 8,4 9 9,6 9,6
±1 % with any power factor and speed variations between -5% +30%
H
Brushless
12 ends
without damping cage
86,1 86,2 85,9 / 86,6 87,1 87,2 87,3
86,2 86,5 86,4 / 87 87,2 87,4 87,6
83,7 83,8 83,8 / 84,5 84,6 84,7 84,8
80,9 80,8 80,6 / 81,6 81,4 81,5 81,8
216,1 195 181,2 / 227,3 218,0 212,3 195
18,95 17,1 15,89 / 19,93 19,12 18,62 17,1
13,52 12,2 11,33 / 14,22 13,64 13,28 12,2
78,7 71 66,0 / 82,8 79,4 77,3 71
78,7 71 66,0 / 82,8 79,4 77,3 71
26,6 24 22,3 / 28,0 26,8 26,1 24
17,17 15,5 14,40 / 18,07 17,33 16,88 15,5
3,88 3,5 3,25 / 4,08 3,91 3,81 3,5
0,58 0,62 0,68 / 0,42 0,52 0,58 0,62
023>003>
0,6 0,7 0,8 / 0,4 0,45 0,5 0,6
2,3 2,4 2,6 / 2,3 2,4 2,4 2,5
1 hour in a 6 hours period 110% rated load
300
0,582
1,032
06,01 : rotatS714,0 : rotoR
1421 1409 1444 / 1424 1469 1550 1536
54 < FIT% 2 < FHT
EN61000-6-3 EN61000-6-1. For others standards apply to factory
2 / 2
3,7 / 3,7
IP 23 (other protection on request)
6309-2RS
6207-2RS
25
13,3
89
2250
3
0,05
0,022
0,91
0,018
Control System
PowerLink PLC-920 generator controllers integrating digital, intelligent and network techniques are used as the automatic control systems for diesel generators. It can carry out functions including pre-alarm, warning & electrical trip, fail monitoring and controls etc.
PLC-920 (Optional)
FEATURES
FUNCTION
Pre-AlarmEngine temperatureOil pressureOver/under voltageOver/under frequencyOver/under speedWarning & Electrical tripOver currentShort circuitErrorOver/under speedSpeed lossBattery lowBattery highMaintenanceOver currentShort circuitEngine stopCan busCharge alternator
Fail monitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltageCharging failShutdownWarningControlsFuel and stop solenoidECU power and stopStarter motorAutomatic generator startPreheatExternal alarm hornEngine coolingIdle mode
SPECIFICATION
Parameter configuration via RS-232 serial communication; Log last 50 events & alarm information with measured values;Statistics records;Remote start/stop; Speed sensing from alternator voltage or magnetic pickup;Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection;Automatic transfer switching control and engine control; Adjustable start, load and stop timers.
Dimensions: 111mm*81mm*61mm Protection: IP65 at front panelOperating temperature: -20℃to 70℃Max. Operating current is 360mASender measurement: 0 to 1300 ohm
Panel cut-out: 81mm*70mmWeight: approximately 0.3kgDC battery supply voltage: 8 to 32VdcCT secondary: 5AAccuracy: 1%FS, resolution: 1 ohm
Gene
ral a
cces
sory
Oper
ator
Inte
rfac
eM
easu
rem
ent a
nd In
stru
men
tatio
nSh
utdo
wn
Prot
ectio
n an
d In
dica
tion
Thre
shol
d W
arni
ng&I
ndic
atio
nPa
ralle
ling
Capa
bilit
yPo
wer
Tran
sfer
Func
tion
Envi
ronm
ent
Mon
itorin
g Fu
nctio
n
Engi
neEn
gine
Alta
mat
orAl
tam
ator
Mai
ns E
xpre
ssio
n
AVRElectronic GoverningGlow plug controlCycle Cranking(MODBUS)NetworkingFault Historymanual start/stopAuto/remote startRegular TestAuto operation LEDManual operation LEDCommon Shutdown LEDCommon warning LEDFail to start LEDEmergency stop(local)Alphanumeric screenRemote start input active LEDAlarm reset Oil pressure Water Temperture Engine Speed Hours Run Number of Starts Battery Voltage Coolant Temperature 3PhaseL-L Voltage&Frequency 3phase Current Frequency kWh Apparent Power Active Power and Reactive Power Power Factor Per PhasekW, kWr Per Phase kVA Phase Voltage Output Power Grid Line Voltage Grid Phase Voltage Grid Frequency
Low Fuel Level High Fuel Level Low Oil Pressure High Water Temperature Failure to Stop Failure to Start Controlable start circles/times Overspeed Under&Over Voltage Under&Over Frequency Overcurrent Earth Leakage Reverse Power Reverse kWrLow Oil PressureLow Water TemperatureHigh Water TemperatureLow Water LevelLow/High Battery VoltageFailure to ChargeOvercurrentOverloadGenset Under/Over VoltageGenset Under/Over Frequencyunder/over SpeedHigh Engine TemperatureEarth LeakageSynchroscope(Independent Bus) Active and Reactive Power Control Synchroscope(Shared Bus) Synchronization Dector Peak Lopping
Automatic Transfer Hard Closed Transition Soft Closed Transtion Gen/Mains Breaker Gen/Mains Breaker Status Protection Speed/Voltage Control Power Indication Fuel&solenoid Valve Control Startor Control Preheating Mains Transfer Switch (Standard) Mains Transfer Switch (Emergency)Operating Temperature (-40℃-70℃) Ambient Temperature (-25℃-45℃) Humidity≤80%
Grid Over/Under Voltage Control Grid Over/Under Frequency Control Remote Start Output(Load/No-load) Optional Relay Output Remote Telecom Control with All Functions Engine Instrument Monitoring Altemator Output Instrument Monitoring Connection Point with All-around Setting For 6 Users 3 Users Input Connection Point LCD Light Control of Low Light Operation Environment Safe PIN CodeRS232/485 Interface Language Selection Multi-Language Function
MODEL
Standard Optional Impossible
PLC-920 PLC-7420
Control System function list
EP Series
WPS6 / WPS6S
EP Series
WPS6 / WPS6S
Control System
PLC-7420
Digital, intelligent controlsystem allows easier operation.
FEATURES
Microprocessor control, with high stability and credibilityMonitoring and measuring operational parameters of themains supply and gensetIndicating operation status, fault conditions, all parame-ters and alarmsMultiple protections; multiple parameters display, likepressure, temp. etc.Manual, automatic and remote work mode selectable
Real time clock for time and date display, overall runtimedisplay, 250 log entries
Overall power output display
Integral speed/frequency detecting, telling status ofstart, rated operation, overspeed etc.Communication with PC via RS485 OR RS232 interface,using MODBUS protocol
PLC-7420 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control. and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automaticallyshut down the engine and indicate the engine failure.
EP Series
WPS6 / WPS6S
Engine Alternator Generator Set Fuel System Canopy
Exhaust System Cooling System Control Panel Voltages
● Water Jacket Preheater● Oil Preheater
Optional
● Winding Temperature Measuring Instrument● Alternator Preheater● PMG ● Anti-damp and anti-corrosion treatment● Anti-condensation heater
● Tools with the machine ● Low fuel level alarm● Automatic fuel feeding system● Fuel T-valves
● Trailer
● Oil with the machine ● Protection board from hotness
● Front heat protection● Coolant (-30°C)
● Remote control panel● PLC-920● PLC-7420● ATS
● 415/240V● 400/230V● 380/220V● 220/127V● 200-115V
Lubricating System
www.powerlinkworld.com
PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact the salesman before ordering.
EP Series / May.2013