EP Series UPS

15
GE Power Quality EP Series UPS

Transcript of EP Series UPS

Page 1: EP Series UPS

GE Power Quality

EP Series UPS

Page 2: EP Series UPS

GE C&I PWQ AsiaSep., 2006 2

1. Market intelligence

2. Power Model

3. Features

4. Cabinet views

5. Technical description

6. Battery management

7. Communication

Content

Page 3: EP Series UPS

GE C&I PWQ AsiaSep., 2006 3

Pluggable market

kVA CAGR< 1 4.8%1 - 5 8.4%

5.1 - 20 9.6%21 - 100 9.9%101 - 250 8.5%251 - 1000 6.3%

> 1000 3.7%

2006: $5.1B

<5kVA = 52% of global market

Total <20kVA equals 68% of global market

< 1kVA18%

>200 kVA13%

1-5 kVA34%

5.1-20 kVA16%

21-50 kVA9%

50-200 kVA10%

15%

33%18%

16%

10% 6% 2% <1kVA

1 - 5kVA

5 - 20kVA

20 - 100kVA

100 - 250kVA

250 - 1000kVA

>1000kVA

China

•Dominated by China made

•APC – made in Suzhou

•Local brands – Santak, Delta, Powercom etc

•Clones – illegal copies

Rest of Asia

•International brands – China or Taiwan sourced

•APC – own manufacturing

•MGE, Liebert, Powerware – OEM or ODM with Santak, Delta or Powercom

AsiaGlobal

2006: $1.4B

Page 4: EP Series UPS

GE C&I PWQ AsiaSep., 2006 4

EP series family

Tower ModelStandard Model

• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA

• With internal battery providing 5~7 mins back time

Long runtime model

• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA

• Without internal battery

• With high capacity internal battery chargerRack Model

Standard Model (Only)

• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA

• With internal battery providing 5~7 mins back time

• Battery is in additional cabinet for 2000/3000/6000VA

Page 5: EP Series UPS

GE C&I PWQ AsiaSep., 2006 5

Feature

General

• Double conversion, on line (VFI)

• LED display – overload, on-line & battery status

• Full digital microprocessor controlled

• Programmable computer shutdown

• Lightning and transient surge protection

• Automatic bypass switch

• Battery Start (cold start)

Performance

• Input Power Factor: 0.97/0.98

• Wide input voltage window (115~300Vac/0.7~3K, 176~276Vac/6KVA)

• Frequency (50/60HZ), Voltage (220/230/240), auto sensing

Battery

• Programmable automatic test

• Protection against deep discharge

• Extended runtime available and auto-recognition

Communication

• RS232, USB

• SNMP

Page 6: EP Series UPS

GE C&I PWQ AsiaSep., 2006 6

Cabinet view

700/1000VA

Front Panel

2000/3000VA

6000VA

700/1000VA (2U)

2000/3000VA (2U)

6000VA (3U)

Page 7: EP Series UPS

GE C&I PWQ AsiaSep., 2006 7

Cabinet view Rear Panel (Tower)

Page 8: EP Series UPS

GE C&I PWQ AsiaSep., 2006 8

Cabinet view Rear Panel (Tower)

Page 9: EP Series UPS

GE C&I PWQ AsiaSep., 2006 9

Cabinet view Rear Panel (Rack)

Page 10: EP Series UPS

GE C&I PWQ AsiaSep., 2006 10

Block Diagram

700/1000VA

2000/3000VA

6000VA

Page 11: EP Series UPS

GE C&I PWQ AsiaSep., 2006 11

Battery

Model EP 700 T/R EP 1000 T/R EP 2000 T/R EP 3000 T/R EP 6000 T/R

Num. & Model

3x12V

7.2Ah

3x12V

7.2Ah

3x12V

7.2Ah

3x12V

7.2Ah

3x12V

7.2Ah

Model 100% Load

50% Load

EP 700 T/R 5 mins 10 mins

EP 1000 T/R

5 mins 10 mins

EP 2000 T/R

5 mins 10 mins

EP 3000 T/R

5 mins 10 mins

EP 6000 T/R

7 mins 14 mins

Standard Model

Tower & Rack

Long Runtime Tower Model

Model EP 700 LRT EP 1000 LRT

EP 2000 LRT

EP 3000 LRT

EP 6000 LRT

Charging Current (max)

7A 8A 9.6A 9.6A 4.3A

Page 12: EP Series UPS

GE C&I PWQ AsiaSep., 2006 12

Communication

Connection

• RS232, USB

• LAN (SNMP)

• Internet

Page 13: EP Series UPS

GE C&I PWQ AsiaSep., 2006 13

Communication

Page 14: EP Series UPS

GE C&I PWQ AsiaSep., 2006 14

Package

• Olympics• Product pictures• Key features• Back panel labeling

Listing all connectivity and electrical connections

• Internal CD packaging for software connectivity.

Box Labeling

Page 15: EP Series UPS

GE C&I PWQ AsiaSep., 2006 15

Q&A