Download - DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE …€¦ · project: title: drawn by: soprema technical support, ggalloway no.: revision: date: date: 1.12.2017 scale: nts drawing

Transcript
Page 1: DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE …€¦ · project: title: drawn by: soprema technical support, ggalloway no.: revision: date: date: 1.12.2017 scale: nts drawing

PROJECT:

TITLE:

DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY

NO.: DATE:REVISION:

DATE: 1.12.2017

SCALE: NTS

DRAWING NUMBER:

US.WSBS.03.14bUSAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS.

PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING.

US CORPORATE ADDRESS310 QUADRAL DRIVE

WADSWORTH, OHIO 44281www.soprema.usTel:330.334.0066

W L L A M G R A N T A L L W A Y

DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE CUSTOM LAYERING

NOTES:1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL

INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THEDETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES.

2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCALCODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS.

3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS4. FOR 90° TRANSITIONS, FLASHING PLIES MUST MEET THE FOLLOWING REQUIREMENTS: HEAT WELD OR SELF-ADHERED POLYESTER REINFORCED FLASHING BASE PLY AND FULLY REINFORCED

LIQUID APPLIED FLASHING CAP SHEET.5. SOPREMA RECOMMENDS 8 INCH VERTICAL FLASHING HEIGHTS BEYOND OVERBURDEN. FLASHING DETAILS SHOWN INCLUDE MINIMUM DIMENSIONS TO MEET WARRANTY REQUIREMENTS.

CONTACT SOPREMA FOR ADDITIONAL REQUIREMENTS.6. DO NOT APPLY ALSAN RS LIQUID APPLIED SYSTEMS OVER SBS MODIFIED BITUMEN MATERIALS ADHERED USING COLPLY OR COPLY MODIFIED ADHESIVES OR CEMENTS. HOT AIR WELD, TORCH

APPLY, OR ADHERE THE SBS MODIFIED BITUMEN MEMBRANE AND FLASHINGS WITH COLPLY EF IN ALL AREAS WHERE ALSAN RS WILL BE APPLIED.

CANT

WEATHERPROOF MEMBRANE

ROOF EDGE SYSTEM

EXTEND REINFORCING FABRIC AMINIMUM OF 8" ONTO CAP SHEET

ALSAN RS

CAP SHEETCAP SHEET

BASE PLYBASE PLY

2 PLY SBS MEMBRANE,NON-INSULATED,

PARAPET WALL WITH LIQUID FLASHING

BASE SHEET/ANCHOR SHEET

BASE SHEET/ANCHOR SHEET

BARRIER BOARD

DECKDECKDECKDECK

BARRIER BOARD

DECKDECK

BARRIER BOARD

DECKDECK

BARRIER BOARD

DECK

BARRIER BOARD

DECKDECK

BARRIER BOARD

BASE SHEET/ANCHOR SHEETBASE SHEET/ANCHOR SHEET

FASTEN AT 8" O.C.IN BOTH DIRECTIONS

FASTEN AT 8" O.C.IN BOTH DIRECTIONS

ALSAN RS

EXTEND ALSAN RS A MAXIMUM OF1/4" BEYOND REINFORCING FABRIC

EXTEND REINFORCING FABRIC AMINIMUM OF 4" BEYOND OVERBURDEN

EXTEND REINFORCING FABRIC AMINIMUM OF 8" ONTO CAP SHEET

EXTEND ALSAN RS A MAXIMUM OF1/4" BEYOND REINFORCING FABRIC

EXTEND REINFORCING FABRIC AMINIMUM OF 4" BEYOND OVERBURDEN

STRIP-IN ALL TRANSITIONS USING REINFORCEDLIQUID-APPLIED FLASHING MINIMUM2" VERTICALLY AND 2" DIAGONALLY

REINFORCING FABRICREINFORCING FABRIC

ALSAN RS

POLYESTER REINFOREDFLASHING BASE PLY

STRIP-IN ALL TRANSITIONS USINGSBS FLASHING MINIMUM

3" VERTICALLY AND 3" HORIZONTALLY

EXTEND REINFORCING FABRIC AMINIMUM OF 8" ONTO CAP SHEET

EXTEND ALSAN RS A MAXIMUM OF1/4" BEYOND REINFORCING FABRIC

EXTEND REINFORCING FABRIC AMINIMUM OF 4" BEYOND OVERBURDEN

REINFORCING FABRIC

ALSAN RS

POLYESTER REINFOREDFLASHING BASE PLY

STRIP-IN ALL TRANSITIONS USINGSBS FLASHING MINIMUM

3" VERTICALLY AND 3" HORIZONTALLY

EXTEND REINFORCING FABRIC AMINIMUM OF 8" ONTO CAP SHEET

EXTEND ALSAN RS A MAXIMUM OF1/4" BEYOND REINFORCING FABRIC

EXTEND REINFORCING FABRIC AMINIMUM OF 4" BEYOND OVERBURDEN

REINFORCING FABRIC

ALSAN RS

STRIP-IN ALL TRANSITIONS USING REINFORCEDLIQUID-APPLIED FLASHING MINIMUM

2" VERTICALLY AND 2" HORIZONTALLY

OVERBURDEN NOT SHOWNFOR CLARITY, REFER TOWATERPROOFINGOVDERBURDEN DETAILS

OVERBURDEN NOT SHOWNFOR CLARITY, REFER TOWATERPROOFINGOVDERBURDEN DETAILS