CONTROL AB320A5200
LIST OF PARAMETERS
CONNECTION DIAGRAMTIMING DIAGRAMS
No. 402286 English
FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORSGMBH & CO KG SINGAPORE PTE. LTD.
+
-
>>
P
E
0
I
KL2334a
EFKA AB320A52003
CONTENTS Page
1 Table of Adapter Cords 5
2 Putting into Service 6
3 Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) 7
4 Operating Elements and Socket Connectors 84.1 Position of Operating Elements and Displays 84.2 Position of the Socket Connectors 94.3 Connection Diagram 104.4 Connection of a Sewing Light with Transformer 134.5 Adapter Cords 145 Timing Diagrams 29
6 List of Parameters 566.1 Preset Values Depending on Mode 566.2 Operator Level 586.3 Technician Level 606.4 Supplier Level 657 Error Displays 78
8 Slide-in Strips for the V810/V820 Control Panels 79
EFKA AB320A52005
1 Table of Adapter Cords
Setting the functional sequence using parameter 290
Mode Designation Adapter Outputs
Power transistors !!!! FL VR M1 M2 M3 M4 M5 M6ST2/35 ST2/34 ST2/37 ST2/28 ST2/27 ST2/36 ST2/32 ST2/30
0 Lockstitch; e. g. Functions FL VR FA1 FA2 FW FA1+2 ML MSTBrother (737-113, 737-913) 1112814 FL VR FA1 + FA2 FWAisin (AD3XX, AD158, 3310; EK1) 1112815 FL VR FA1 + FA2 FWPfaff (563, 953, 1050, 1180) 1112841 FL VR FA1 FA2 FW MLDürkopp Adler (210, 270) 1112845 FL VR FA1 + FA2 FW
2 Lockstitch; e. g. Functions FL VR FA FSPL FL1 ML MSTSinger (212 UTT) 1112824 FL VR FA FSPL FL1
3 Lockstitch; e. g. Dürkopp Adler (467) FL VR FA FSPL FW ML MST
4 Chainstitch; e. g. Union Special Functions FL FA-R M1 FA-V FW STV ML(34000 and 36200 replacement for US80A)1112865 FL FA-R FA-V FW ML(CS100 and FS100) 1112905 FL FA-R M1 FA-V FW ML
5 Chainstitch; parallel sequence Functions FL STV M1 M2 M3 M4 ML MSTBag sewing machine Union Special Functions FL IMP BR ML MSTYamato (VC series) 1112818 FL STV FA FWYamato (VG series) 1113178 FL STV FA FW MLKansai (RX 9803) 1113130 FL FA FW MLPegasus (W500/UT, W600/UT/MS 1112821 FL STV FA FA FWwith or without stitch condensing)Brother (FD3-B257) 1112822 FL STV FA FA FWUnion Special (34700) 1112844 FL STV FA FA FW NKGlobal (CB2803-56) 1112866 FL FARimoldi (F27) 1113096 FL FW FAO FAU ML
6 Chainstitch; tape cutter/fast scissors FL STV M1 M2 AH1 AH2 ML MST
7 Overlock FL KS M1 M2 AH FSPL ML MST
8 Backlatch Functions FL PD≤≤≤≤-1 PD≥≥≥≥1 PD≥≥≥≥1* ML MSTPegasus 1113234 PD≤-1 PD≥1
9 Backlatch Functions FL PD≤≤≤≤-1 PD≥≥≥≥1 PD≥≥≥≥1* ML MSTYamato (ABT3) 1112826 PD≤-1 PD≥1Yamato (ABT13, ABT17) 1113205 PD≤-1 PD≥1
10 Lockstitch; e. g. Functions FL FA-R FSPL FA-V FW VR ML MSTUnion Special (63900AMZ replacement 1112823 FL FA-R FA-V FW MLfor US80A) and on Refrey lockstitch machines
14 Lockstitch; e. g. Functions FL VR FA1+2 FA2 FW FA1 ML MSTJuki (5550-6) 1112816 FL VR FA1+2 FWJuki (5550-7) 1113132 + FL VR FA1+2 FZ FW(position sensor incorporated in the 1113157handwheel)
15 Backlatch Pegasus (SSC100) FL KS/KB KB KS FSPL AH ML HP
16 Overlock; feed-off-the-arm machine e.g.Yamato (FD62) FL KS RB M2 AH FSPL ML MST
17 Chainstitch; Pegasus FL LFA FA STS ML
20 Lockstitch; Juki (LU1510-7) 1113200 FL VR FA FSPL ML MST
21 Chainstitch; Yamato (stitch lock) 1113178 FL STS FA STV FW ML
23 Lockstitch; Dürkopp Adler (271...275) FL VR FA ML FW FSPL HP MST
24 Chainstitch; Pegasus (MHG-100) 1113267 FL FA FA FW
*) The signal issued at this output is inverted!
ATTENTION!Before switching functional sequences, detach cables from the inputs and outputs! Please ensure that the
machine installed provides the functional sequence to be set! Then proceed with the setting using parameter290!
EFKA AB320A5200 6
Explanation of letter symbols of the previous page and chapter ”Timing Diagrams“
Outputs:
FL = Sewing foot lifting FL1 = Sewing foot lifting without pulsingVR = Backtacking STV = Stitch condensingFA = Thread trimmer FA1 = Thread trimmer pos. 1...1AFA2 = Thread trimmer pos. 1A...2 FA1+2 = Thread trimmer pos. 1...2FA-V = Thread trimmer forward FA-R = Thread trimmer backwardFAU = Bobbin thread trimmer FAO = Needle thread trimmerFSPL = Thread tension release AH = Tape cutterFW = Thread wiper AH1/AH2 = Fast scissorsML/NK = Machine running / Needle cooling KS = Chain suctionRB = Chain blowing in opposite direction STB = Blow fabric onto stackKB = Chain blowing KS+KB = Chain suction + blowingMST = Machine at standstill HP/FF1 = High lift for walking foot /PD≥1 = Pedal steps 1...12 flip-flop 1PD=0 = Pedal step 0 PD≤-1 = Pedal steps –1 / -2L-STL = Indicator lamp for stitch length PD-2 = Pedal step -2FZ = Thread puller DR-UK = Reversal of motor directionIMP = Impulse STS = Stitch lockLFA = Top cover thread cutter BR = Hot thread chain cutting
2 Putting into ServiceBefore putting the control into service, the following must be ensured, checked and/or adjusted:
" The correct installation of the drive, position transmitter and accompanying devices, if necessary
" The correct selection of the trimming operation by means of parameter 290
" If necessary, the correct adjustment of the direction of motor rotation by means of parameter 161
" The correct selection of the functions of keys (inputs) by means of parameters 240...249
" The setting of the transmission ratio between motor shaft and machine shaft by means of parameter 272
" The setting of the type of position sensor by means of parameter 270
" If necessary, the setting of the number of angular degrees after the sensor position by means of parameter 271
" If necessary, the setting of the positions by means of parameter 171(possible with all settings of parameter 270)
" The correct positioning speed by means of parameter 110
" The correct maximum speed compatible with the sewing machine by means of parameter 111
" The setting of the remaining relevant parameters
" Start sewing in order to save the set values
See instruction manual for details!
EFKA AB320A52007
3 Setting and Putting into Service with the Aid of the Fast InstallationRoutine (SIR)
The Fast Installation Routine (SIR) passes through all parameters necessary for programming the functional sequence andthe positions.
Input parameter 500
Parameter for functional sequence “thread trimming operations”
Parameter for direction of motor rotation
Parameter for transmission ratioImportant! The transmission ratio should bedetermined and indicated as precisely as possible.
Parameter for type of position sensor
Parameter for position 1
Parameter for position 2
The values can be varied by pressing the +/- keys. When the parameter is displayed on the V810 control panel, pressthe E key once more for the value to be displayed.
Exit the routine any time by pressing the P key once, and select a new parameter. Exit programming by pressing the P keytwice, and the drive is ready for a new sewing operation.
See instruction manual for details!
F-272
End SIR
F-451
F-453
F-270
NoP
E
E
E
E
Yes
KL2438a
F-161
F-290
F-500
Code 3112
F-200
E
E
>>
E
E
EFKA AB320A5200 8
4 Operating Elements and Socket Connectors
4.1 Position of Operating Elements and Displays
S1 P key" Call or exit programming mode
S2 E key" Start backtack single / double / off" Enter key for modifications in the programming mode
S3 + key" End backtack single / double / off" Increase of the value indicated in the programming mode
S4 – key" Automatic sewing foot lifting at stop in the seam On/Off" Automatic sewing foot lifting after thread trimming
On/Off" Decrease of the value indicated in the programming mode
S5 >> key" Basic position 1 or 2" Shift key in the programming mode
LED1 Indicator for single start backtack
LED2 Indicator for double start backtack
LED3 Indicator for single end backtack
LED4 Indicator for double end backtack
LED5 Indicator for automatic sewing foot lift at stopin the seam
LED6 Indicator for automatic sewing foot lift afterthe thread trimming operation
LED7 Indicator for basic position “needle position 1“
LED8 Indicator for basic position “needle position 2“
Display 3 digitsAB320A5200
KL2472
LED4LED5LED6LED7LED8
Display
LED1LED2LED3
+
-
P
E
S4
S5
S1
S2
S3
0
I
EFKA AB320A52009
4.2 Position of the Socket Connectors
B2 Socket for sensors
B18 Socket for light barrier module
B41 Socket for motor power supply
B80 Socket for actuator
B776 Socket for V810/V820 control panel
ST2 Socket for solenoid inputs and outputs /solenoid valves / displays / keys and switches
B 41
M
B18
KL2333
ST2
LSM ...
B2
B41
B 2
B 18
M
B776
ST2
V8 . .
B 80
B 776
EB ... B80
EFKA AB320A5200 10
4.3 Connection Diagram
Inputs switched to 0V
in1 - Input 1 i10 - Input 10 M9 - Output 9in2 - Input 2 M1 - Output 1 M10 - Output 10in3 - Input 3 M2 - Output 2 M11 - Output 11in4 - Input 4 M3 - Output 3 FL - Sewing foot liftingin5 - Input 5 M4 - Output 4 VR - Backtackingin6 - Input 6 M5 - Output 5 POS1 - Position 1in7 - Input 7 M6 - Output 6 POS2 - Position 2in8 - Input 8 M7 - Output 7 GEN - 512 generator impulsesin9 - Input 9 M8 - Output 8 R-N-EXT - External potentiometer for
speed limitation (50kΩ)
ATTENTION!When connecting the outputs, ensure that a total power of 96VA constant load will not
be exceeded!
EFKA AB320A520011
Inputs switched to +24V
1) Nominal voltage 24V, no-load voltage max. 30V momentarily after power on2) Transistor output with open collector max. 40V, 10mA3) Nominal voltage 15V, Imax = 30mA4) Nominal voltage 5V, Imax = 20mA*) Front view of the socket (component side) and/or rear view of the plug (soldering side)
ATTENTION!When connecting the outputs, ensure that a total power of 96VA constant load will not
be exceeded!
EFKA AB320A5200 12
POS2 OUT - Output for position 2POS IN - Input for positionsG1/G2 OUT - Output of generator impulsesTXD/RXD - Serial transmission linesLSM IN - Possibility of connecting a light barrier module to socket B18/8
(If parameter 239 = 0, the light barrier function is selected.Identification of the signal when switched to 0V.)
LSM002 - Reflection light barrier module
If parameter 239 is set to 1...43, a key can be operated on the input of socket B18/8.
+5V = Connect lefthand pins 1 and 2 with jumper (factory setting)+15V = Connect righthand pins 3 and 4 with jumper
1) Nominal voltage +15V, 100mA (repluggable to +5V, 100mA)2) Transistor output with open collector max. 40V, 10mA*) Front view of the socket (component side) and/or rear view of the plug (soldering side)
B80B2
B18
J41 3
2 4
+5V
J431
42
KL2351
+15V
J4
ATTENTION!Before opening the cover, turn power off!
EFKA AB320A520013
4.4 Connection of a Sewing Light with Transformer
" Switch off the control and remove mains plug from outlet" Unscrew the control unit from the machine table" Loosen 4 screws (A)" Remove the mounting plate" Loosen 2 screws (B) each at the front and at the rear" Open the left part of the housing" Pull the sewing light cable through the cable bushing" Area (C): Connect strands with clamp on the printed circuit board" Insert earth lead into plug-in device on the housing part" Close and screw-connect the housing" Mount the control unit on the machine table
CAUTION!When the sewing light is connected, it is always current-carrying (230V), even ifthe control unit is switched off! Only one sewing light with transformer can be
connected to the control unit!
A
B
C
-
>>
+
P
E
KL2399
0
I
ATTENTION!Before opening the cover, turn power off!
EFKA AB320A5200 14
4.5 Adapter Cords
Adapter cord for AISIN models AD3XX, AD158, 3310 and EK1
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 0Setting the functions of the keys Input in1 ! Set parameter 240 = 16
Input in3 ! Set parameter 242 = 1
Adapter cord for BROTHER models 737-113 and 737-913
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 0Setting the functions of the keys Input in1 ! Set parameter 240 = 16
Input in3 ! Set parameter 242 = 1
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
7 in1
37
20
19
SUB-D-37
1
37 M 1
35
VR
FL
34
28 M 2
+ 24V26
27 M 3
+ 24V
+ 24V
+ 24V
16
17
18
19 0V
ST2Nr. 1112814
6 in3
1
4 0V
56
6
KL2233
24V
NH T
FL
0V
+
4
6
5
5
2
4
3
1
1
3
2
8
0V 12
12
FW
24V
ZVR
VR
24V
+
+
6
9
10
8
9
7
11
11 10
4
7
324V
FA1+ 2
+
4
52 1
1
2
3
Nr. 1112815
19 37
27 M 3
37
35
34
FL
VR
28 M 2
M 1
SUB-D-37
1
+ 24V
+ 24V
+ 24V
+ 24V26
20
16
17
18
19 0V
7 in1
1
4 0V
6 in3
ST2
3
+ 24V
VR
FW
+ 24V
2
32
4
3
11
3
4
0V
NH T
0V
FA1+ 2
+ 24V
ZVR
2 2
1
4
3
2
1
1
3
2
4
1
KL2234
+ 24V
FL 4
1
2
33
2
4
1
EFKA AB320A520015
Adapter cord for BROTHER model FD3 B257
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in1 ! Set parameter 240 = 7
Input in3 ! Set parameter 242 = 18Input in4 ! Set parameter 243 = 16Input in5 ! Set parameter 244 = 17
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr. 1112822
37
34
35 FL
VR
M 1
1
19
SUB-D-37
ST2
20
+ 24V
+ 24V
+ 24V
+ 24V
18
28 M 2
37
26
27
19 0V
M 3
17
16
in4
in17
8
+ 5V
0V
in36
in55
1
2
4
12LSP
FL
+ 24V
6
5
4
2
3
1
5
4
6
KL2241
1
3
2
0V
+ 24V
FA
FA
+ 24V
+ 24V
STV
FW
5
10
11
6
8
9
76
9
12
4
3
1
2
7
3
5
+ 5V
STVU
ENTK
LSP
ZSTV
0V
4
6
5
2
4
2
3
1
1011
5
84
7
2 1
37
61
EFKA AB320A5200 16
Adapter cord for DÜRKOPP ADLER models 210, 270
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 0Setting the functions of the keys Input in1 ! Set parameter 240 = 16
Input in3 ! Set parameter 242 = 1Input in4 ! Set parameter 243 = 3Input in5 ! Set parameter 244 = 17
Adapter cord for GLOBAL model CB2803-56
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in1 ! Set parameter 240 = 6
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
19 37
SUB-D-37
37 M 1
35 FL
28
34 VR
M 2
20 POS1
27 M 3
16
18
19 0V
+ 24V
+ 24V
1 20
ST2
Nr. 1112845
7
8
in1
in4
4
5
6
1
in5
in3
0V
6
KL2259a
ZVR
EST
7
4
5
6
53
7
10
NH T
0V
VRU
FA1+ 2
VR
FL
1
2
32
4
8
9
1 6
2
34
5
1
POS1
+ 24V 7
6
0V
FW
4
5
1
2
3
107
89
Nr. 1112866
19
SUB-D-37
1
ST2
+ 24V
+ 24V
3735 FL
37
20
27 M 3
17
18
7 in1
1
4 0V
3
1224V
0V
FL
LSP
+
12
6
10
6
8
9
7
11
9
24V
FA
+
4
5
1
2
3
KL2301
11
54
7
10
8
2 1
EFKA AB320A520017
Adapter cord for JUKI model 5550-6
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 14Setting the functions of the keys Input in1 ! Set parameter 240 = 16
Adapter cord for JUKI model 5550-7
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 14Setting the functions of the keys Input in1 ! Set parameter 240 = 16
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
**) Front view (component side) of the Molex Minifit plugs.
Nr. 1112816
37 M 1
4 0VSUB-D-37
19
1
+ 24V
27 M 3
3734
35
VR
FL
26
+ 24V
+ 24V
+ 24V
20
16
17
18
11 in2
ST21
KL2235b
3
11FA1+ 2
12
+ 24V
FL
2
1
2
1
2
1110
+ 24V
+ 24V
VR
+ 24V
FW
6
8
9
76
9
12
4
53
7
10
1
54
8
ZVR
0V
1
2
Nr. 1113132
19
1
SUB-D-37
M 228
M 1
+ 24V
VR
FL
37
3734
35
33
+ 24V16
M 3
+ 24V
+ 24V
0V
+ 24V
20 17
18
19
27
26
ST2
in2
1
11
ZVR 5
+ 24V 13
+ 24V
FL
14
2
1 1 2
KL2363
VR 6 7
+ 24V
+ 24V
+ 24V
0V 12
10
8
9
7
11 1
23456
14
11
10
1312
9 8
FA1+ 2
FW
FZ 4
2
3
1
EFKA AB320A5200 18
Adapter cord for JUKI model LU1510-7
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 20Setting the functions of the keys Input in1 ! Set parameter 240 = 13(Automatic setting) Input in3 ! Set parameter 242 = 31
Input in4 ! Set parameter 243 = 32Input in6 ! Set parameter 245 = 16Input in7 ! Set parameter 246 = 13
in1 = Input high lift for walking foot with speed limitation n10 (operational mode not stored) for knee switchin3 = Input speed limitation bit 0 (S1)in4 = Input speed limitation bit 1 (S2)in6 = Input intermediate backtackin7 = Input high lift for walking foot with speed limitation n10 (operational mode not stored) for additional
pushbutton at the machine head
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
**) Front view (component side) of the Molex Minifit plugs.
37
34
35
33
30
10
15
+ 24V
FL
M 1
+ 24V
VR
FL
M 6
+ 24V
0V
S2
H P in
2
1
KL2437
1 2
6 4
9
12
15
8
9
7 87
10
13
14
11
6
5
5
SUB-D-37
1919
37
28
26
18
17
1
16
9
12
20 8
6
ST21
4
14
13
12
10
11
0V
M 2
+ 24V
+ 24V
+ 24V
FSPL
+ 24V
0V
S1
H P out
+ 24V
in7
in6
in4
in3
+ 24V
0V
+ 24V
VR
ZVR
4
2
3
1
3 2 1
8
9
7
6
5
5 12
1
234 11
9 8
10
67
1314
Nr. 1113200
0V
FA
4
2
3
1
EFKA AB320A520019
Adapter cord for KANSAI model RX9803
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in1 ! Set parameter 240 = 7
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr. 1113130
19
1
M 327
M 5
FL
M 1
37
37
35
32
SUB-D-37
+ 24V
+ 24V
+ 24V
+ 24V
in1
26
20
16
17
18
7
ST2
0V
+ 5V
4
2
1
+ 24V
FL
2
1
3
4 3
2
1
4
+ 24V
+ 24V
+ 24V
M L
FA
FW
6
4
2
3
1
54
5
6
KL2362
1
2
3
0V
+ 5V
LSP
33
1
22
1
EFKA AB320A5200 20
Adapter cord for PFAFF models 563, 953, 1050, 1180 without thread monitor
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 0Setting the functions of the keys Input in4 ! Set parameter 243 = 12
Input in5 ! Set parameter 244 = 16
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
KL2261
37 M 1
19 37
SUB-D-37
1 20
ST2
26 + 24V
34 VR
35 FL
27
28
32
M 3
M 5
M 2
16
17
19
18
8
+ 24V
+ 24V
in4
0V
+ 24V
Nr. 1112841
4
1
5 in5
0V
4
VR
+ 24V
ZVR
0V
0V
VR
+ 24V
ZVR
M L
4
1
2
3
2
3
4
1
2
3
6
3
2
1
4
4
5
1
4
2
2
0V
FW
+ 24V
+ 24V
FA1
FA2
FW
+ 24V
+ 24V
FA1
FA2
6
4
53
1
2
3
5
1
2
3
43
1
2
FL
+ 24V
+ 24V
0V
FLEX
VR
5
66
4
1
2
3
4
5
6
1
3
6
1
5
EFKA AB320A520021
Adapter cord for PEGASUS models W500/UT, W600/UT/MS with or without stitch condensing
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in1 ! Set parameter 240 = 7
Attention! When using this adapter cord on a Pegasus machine, the 9-core cable no. 742373-91 must beremoved from the machine!
Adapter cord for PEGASUS backlatch machines
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 8Setting the functions of the keys Input in1 ! Set parameter 240 = 6(Automatic setting) Input in3 ! Set parameter 242 = 10
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr. 1112821
37 M 1
19
1
SUB-D-37
ST2
+ 24V
+ 24V
+ 24V
+ 24V
+ 24V
27 M 3
35 FL
37
33
34 VR
28 M 2
20 17
18
19 0V
16
26
1
2 + 5V
7 in1
+ 24V
STV
2
11
2KL2240
2
8
LSP
0V
+ 24V
FL
+ 24V
+ 5V
2
3
2
1
2
1
2
1
6
8
9
7
1
9
6
+ 24V
+ 24V
FW
FA
FA
4 35
1
2
3
7
54
1
Nr. 1113234
37 M 1
19
1
SUB-D-37
37
20
ST2
0V4
28 M 2
19 0V
6
7
in3
in1
1
0V 2
KL24582
3
2
3
2
14
0V
Ped - 1=
5
6
1
4
0V
N- AUTO
LSP
6
2
3
1
5
5
1
4 1
6
6
5
1=Ped
1
2
3Ped - 1=4
EFKA AB320A5200 22
Adapter cord for PEGASUS model MHG
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 24Setting the functions of the keys Input in1 ! Set parameter 240 = 6
Input in2 ! Set parameter 241 = 13Input in3 ! Set parameter 242 = 28Input in4 ! Set parameter 243 = 22
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr.1113267
33 + 24V
KL2482
35
37
FL
M 1
37
20
SUB-D-37
19
1
ST2
25
26
27
28
32
+ 24V
M 3
M 2
M 5
M 9
15
16
17
18
19
23
+ 15V
0V
+ 24V
+ 24V
+ 24V
M 7
0V4
11
8
7
6 in3
in1
in4
in2
1
2 + 5V
+ 24V
1
2
3
4
5
6
+ 24V
+ 24V
M 9
in2
0V
M 7
2
1
2
1
+ 24V
FL
M 5
2
3
1
5
6
4
2
1
2
1
2+ 24V
2
3
1
LSP
+ 5V
0V
3
4
5
6
7
8
9
+ 24V
+ 24V
FW
FA
1
2
3
1
+ 15V
SEN
0V
FA
1
2
in4
0V
1
2
3
65
4
79 8
23 1
2
2
1
3
1
EFKA AB320A520023
Adapter cord for RIMOLDI model F27
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5
Adapter cord for SINGER models 211, 212 and 591
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 2(Singer model 212UTT)Setting the functions of the keys Input in1 ! Set parameter 240 = 1
Input in3 ! Set parameter 242 = 16
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr. 1113096
19
1SUB-D-37
37
20
ST2
M 532
35 FL
37 M 1
16 + 24V
17
18
+ 24V
+ 24V
M 2
M 3
28
27
1
KL2346
6
5
2
3
4
+ 24V
FW
M L
FAO
FAU
FL
1
4
2
3
5
6
1
Nr. 1112824
37
19
1
SUB-D-37
ST2
+ 24V
+ 24V
+ 24V
+ 24V
26
37
27 M 3
28 M 2
34
35
VR
FL
M 436
33
20
16
17
18
19 0V
7 in1
1
4 0V
6 in3
KL2243
4
FL
0V
+ 24V
FL1
0V
+ 24V
VR
+ 24V
FA2/FA
2
1
3
43
2
1
4
4
6
2
3
1
3
4
2
1
NH T
0V
+ 24V
FW /FSPL
ZVR
4
55
1
2
36
1
2
3
EFKA AB320A5200 24
Adapter cord for UNION SPECIAL models CS100 and FS100
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 4Setting the functions of the keys Input in1 ! Set parameter 240 = 6
Input in3 ! Set parameter 242 = 6
in1 = Input machine run blockage for thread trimming control proximity switchin3 = Input machine run blockage for thread monitor
Adapter cord for UNION SPECIAL model 63900AMZ
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 10
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
FA- R
LSP
+ 15V
FW
0V
+ 24V
FA- V
+ 24V
FL
M L
0V
+ 24V
POS1
LSP
35 FL
37 M 1
SUB-D-37
19 37
33
27
26
28
32
34
1 20
20
15
16
19
7
6
+ 24V
M 3
+ 24V
M 2
M 5
VR
POS1
in1
+ 15V
+ 24V
0V
in3
ST24
1
Nr. 1112905
0V
7 4
KL2306
10
9
83
2
1
6
5
3
4
2
1
65
10
9
78
6
5
4
2
3
1
2
1
6
3
5
4
4
1
2
3
2
3 4
1
Nr. 1112823
19
SUB-D-37
1
ST2
37
37
35 FL
34 VR
20 19 0V
32 M 5
27 M 3
28 M 2
+ 24V
+ 24V
1
17
16
1
10
0V
FW
FA- R
1 2
2
4
33
6
8
9
7
M L
+ 24V
FL
FA- V
4
5
1
2
3
7
1
4
KL2242
6
34
52
9810
EFKA AB320A520025
Adapter cord for UNION SPECIAL model 34700 with stitch lock
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in8 ! Set parameter 247 = 7
Input in9 ! Set parameter 248 = 6
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
FL35
KL2260
M 137
1 20
19
SUB-D-37
VR
M 5
M 3
M 2
+ 24V
+ 24V37
34
32
33
28
27
26
0V
POS1
+ 24V
+ 24V
+ 24V
in9
+ 15V
19
20
13
15
16
17
18
ST2
in8
0V
Nr. 1112844
4
10
1
+ 24V 1
4
3
FL
6
4
5
1
2 3
M L
+ 24V
POS1
STOP
0V
1
2
2
3
4
6
2
3
5
1
4
2
3
STV
+ 24V
2
3
1
3
2
1
10
NK
FA
8
9
4
9
7
+ 15V
LSP
+ 24V
FW
0V
FA
5
6
4
1
2
3
110 8
65
7
EFKA AB320A5200 26
Adapter cord for UNION SPECIAL models 34000 and 36200
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 4Setting the functions of the keys Input in1 ! Set parameter 240 = 6
Input in3 ! Set parameter 242 = 6Input in4 ! Set parameter 243 = 18Input in5 ! Set parameter 244 = 12
in1 = Input machine run blockage for thread trimming control proximity switchin3 = Input machine run blockage for thread monitorin4 = Input unlocking the chain corresponds to function flatseamer (FLAT-S)
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
27 M 3
37
33
34
35
32
28
KL2289
M 5
+ 24V
VR
FL
M 2
19
20
21
22
26
15
16
17
4
5
SUB-D-37
19
1
37
207
8
6
ST21
in5
0V
POS1
POS2
GEN
+ 24V
+ 24V
in1
in4
+ 15V
+ 24V
in3
Nr. 1112865
0V
POS2 6 5 7
10
2
3
5
FW 3
10
+ 15V
LSP
FA- R
5
7
9
8
6
0V 4
1
FL
+ 24V
FA- V
FA- V
2
1
5
6
4
0V
+ 24V
M L
FW
8
2
3
1
POS1 7
2
1
6
3
76
34
5
98
4
3FLAT- S 2
+ 24V
GEN
M L
FL
1
2
3
4
5
+ 24V
POS1
LSP
0V
1
2
3
4
FLEX 3
2
41
2
3
0V
FLAT- S
FLEX
0V
1
2
3
1
2
1
6
8
4
1
EFKA AB320A520027
Adapter cord for YAMATO chainstitch machines VC series
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5Setting the functions of the keys Input in1 ! Set parameter 240 = 7
Adapter cord for YAMATO chainstitch machines VG series
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 5/21Setting the functions of the keys Input in1 ! Set parameter 240 = 7
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
37 M 1
ST2SUB-D-37
19
1
27 M 3
3734
35
VR
FL
+ 24V
+ 24V
+ 24V
20
16
17
18
4 0V
7 in1
1
Nr. 1112818
KL2237
2
FL
+ 24V
STV
+ 24V
2
2
1
2
1
2
1 1
0V
LSP
3
2
1
3
2
1
FW 4
33
4
+ 24V
FA
1
21
Nr. 1113178
19
SUB-D-37
1
ST2
35
37
34
33
3732
27
26
16
17
18
FL
M 1
VR
+ 24V
M 5
M 3
+ 24V
+ 24V
+ 24V
+ 24V
7
20
4
1
in1
0V
4FA 7
0V
LSP
FW
STV
M L
15
14
12
13
11
8
9
101
2
3
+ 24V
FL
+ 24V
+ 24V
+ 24V
+ 24V
5
6
2
4
3
1
5
KL2405
8
7
6
12
11
139
15
14
10
EFKA AB320A5200 28
Adapter cord for YAMATO backlatch machine model ABT3
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 9Setting the functions of the keys Input in1 ! Set parameter 240 = 6(Automatic setting) Input in3 ! Set parameter 242 = 10
Adapter cord for YAMATO backlatch machine models ABT13 and ABT17
Setting the functional sequence Thread trimming mode ! Set parameter 290 = 9Setting the functions of the keys Input in1 ! Set parameter 240 = 6(Automatic setting) Input in3 ! Set parameter 242 = 10
Input in4 ! Set parameter 243 = 34
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Nr. 1112826
19
1
SUB-D-37
ST2
+ 24V
PO S2Q
28 M 2
37 M 1
3733
20
21
6
7
in3
in1
R
0V
1
2
4
+ 5V
6
+ 5V
POS2Q
LSP
5
2
1
6
2
1
4
6
2
3
1
5
4
6
Ped - 1=
N- AUTO
Ped 1=
0V
4
55
1
2
34
3
KL2244
1
2
3
2
1
Nr. 1113205
19
SUB-D-37
1
ST2
28
3737
21
20 7
6
8
M 2
M 1
POS2Q
in1
in3
in4
4
2
1
0V
+ 5V
POS2Q
6
5
KL2439
6
N9- AUTO
+ 5V
LSP
5
1
3
4
2
5
4
6
6
4
2
3
1
5
4
6
6
N12- AUTO
=
=
Ped
Ped
0V
- 1
1
4
5
3
2
1
5
4
3
2
3
1
2
3
1
2
1
EFKA AB320A520029
5 Timing DiagramsMode 0 (lockstitch)
Mark Function Parameter Control V810 V820Mode 0 290 = 0Double start backtack with stitch correction On S2 key 1 key 1 keyDouble end backtack with stitch correction On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204t6 Thread wiper ON period 205t7 Sewing foot switch-on delay after thread wiper 206t8 Start backtack stitch correction 150t9 End backtack stitch correction 151c2 Start backtack stitches forward 000c1 Start backtack stitches backward 001c3 End backtack stitches backward 002c4 End backtack stitches forward 003
- / 0
121
n2
(FA1+ 2)
(M ST)
(M L)ST2/32
30
ST2/36
ST2/M 6
M 5
(FW )
(FA2)
(FA1)
ST2/27
ST2/37
ST2/28
M 4
M 3
M 2
M 1
ST2/20
ST2/21
ST2/35
ST2/34
FL
POS.2
VR
POS.1
+
n
- 2- 1
t3
c2
t8 t1
c1
310
n3
2 3 1 2
0256/M ODE- 0
t9
n4
c3
n2n1
0 1 2
c4
t6 t7
1 2
n7
3
t4 t5
EFKA AB320A5200 30
Mode 2 (lockstitch)
Mark Function Parameter Control V810 V820Mode 2 290 = 2Softstart 134 = 1Single start backtack On S2 key 1 key 1 keySingle end backtack On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n6 Softstart speed 115n7 Trimming speed 116t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202tFL Switch-on delay of sewing foot lifting 211kt2 Thread trimmer ON period 283tFA Stop time for thread trimmer 253SSc Softstart stitches 100c1 Start backtack stitches backward 001c3 End backtack stitches backward 002
c3
NH T
c1
SSc
n6
ST2/21
(M ST)30
ST2/27
(M L)ST2/32
(FSPL)
ST2/28
ST2/35
ST2/36
ST2/34
M 2
M 6ST2/
M 5
M 3
M 4
VR
FL
(FA)
(FL1)
t3
n
ST2/20
+
POS.2
POS.1
-
0 1
- 2
/ 0112
- 1
t1 t3
n1n3 n2
2 3 0
0256/M ODE- 2
tFA
kt2
tFL
n7n4 n7
1 2 3
n1 n1
EFKA AB320A520031
Mode 3 (lockstitch)
Mark Function Parameter Control V810 V820Mode 3 290 = 3Double start backtack On S2 key 1 key 1 keyDouble end backtack On S3 key 2 key 4 keyHigh lift for walking foot 137 = 1
n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116n10 High lift walking speed 117t6 Thread wiper ON period 205t7 Sewing foot switch-on delay after thread wiper 206iFA Activation angle of the thread trimmer 250FSA Thread tension release ON period 251FSE Thread tension release delay depending on angle 252c2 Start backtack stitches forward 000c1 Start backtack stitches backward 001c3 End backtack stitches backward 002c4 End backtack stitches forward 003tHP High lift walking speed run-out time 152cHP Stitch counting high lift for walking foot 185
6
ST2/27
ST2/31
(H P)ST2/7
ST2/32
ST2/28
in1
M 2
M 5
M 11(LH P)
(M L)
(H P)
POS.2
ST2/35
ST2/21
ST2/37
ST2/34
ST2/20
POS.1
ST2/36
M 3
M 1
VR
M 4
FL
(FSPL)
(FW )
(FA)
n
t3
0
- 0- 1
+- 2
/121
c2 c1
t1
1
n3
2 3 1 2 3
cH P
n2 n10
1 2 3 4 5
0256/M ODE- 3
iFA
c3
tH P
7
n2
0
c4
tFA
1 2
n4
1 2
n7
3
FSE FSA
t6
n7
t7
EFKA AB320A5200 32
Mode 4 (chainstitch)
Mark Function Parameter Control V810 V820Mode 4 290 = 4Start stitch condensing On S2 key 1 key 1 keyEnd stitch condensing On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116n12 Automatic speed 118t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t11 Holding power output “stitch condensing” of the thread 213
trimmer backwardkd1 Delay time of the thread trimmer backward 280kt1 ON period of the thread trimmer backward 281kd2 Delay time of the thread trimmer forward M2 282kt2 ON period of the thread trimmer forward M2 283kd3 Delay time of the thread wiper M3 284kt3 ON period of the thread wiper M3 285kdF Switch-on delay of sewing foot lifting 288c1 Stitch counting of start stitch condensing 001c3 Stitch counting of end stitch condensing 002
t4
(FA- R)STVST2/34
kt1kd1
n2
M 4ST2/36
n
POS.1
POS.2
FL
ST2/20
ST2/21
ST2/35
n3
c1
0 1 2 3
t3
4 5 6 7
t1
- 2- 1 0
11/2
+
-
n4
c3
n1
0 1 2 3 4 5
n7
kdF
t11
t5
ST2/32
M 6ST2/30
(M ST)
M 3 (FW )
M 5 (M L)
ST2/27
(FA- V)M 2ST2/28
M 1ST2/37
0256/M ODE- 4
kt3kd3
kt2kd2
EFKA AB320A520033
Mode 5 (chainstitch)
Mark Function Parameter Control V810 V820Mode 5 290 = 5Softstart 134 = 1Start stitch condensing On S2 key 1 key 1 keyEnd stitch condensing On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start stitch condensing speed 112n4 End stitch condensing speed 113n6 Softstart speed 115n7 Trimming speed 116t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204c1 Stitch counting of start stitch condensing 001c3 Stitch counting of end stitch condensing 002c4 Stitch counting at the seam end without stitch regulator 003SSc Softstart stitches 100kdF Switch-on delay of sewing foot lifting 288kd1-kd4 Delay times of outputs M1...M4 280/2/4/6kt1-kt4 ON periods of outputs M1...M4 281/3/5/7
n7n
POS.1
- 2
/
- 1 0
12
+
- 1
0 1
n6
2 3
n3 n1n2
320 1
n4
21
(M ST)M 6ST2/30
ST2/32M 5 (M L)
M 4ST2/36
t3
ST2/34
M 3ST2/27
M 1
M 2
ST2/37
ST2/28
FL
ST2/35
STV
ST2/20
ST2/21
POS.2
t1c1
SSc
0256/M ODE- 5
kt4kd4
t4 t5 t3 c3 c4
kd1 kt1
kt2kd2
kd3 kt3
kdF
EFKA AB320A5200 34
Mode 5 (chainstitch) Union Special, bag sewing machine
Mark Function Parameter Control V810 V820Mode 5 290 = 5Softstart 134 = 1
SAk “Hot thread chain cutting“ (M3) by means of knee switch 198 = 1and sewing foot lift by means of pedal
in1...i10 Function “hot thread chain cutting“ (M3) by means of knee 24x = 42switch
n1 Positioning speed 110n2 Maximum speed 111n6 Softstart speed 115t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204SSc Softstart stitches 100kd2 Delay time for output M2 282 = 0kt2 ON period for output M2 283 = 50mskd3 Delay time for output M3 284 = 1500mskt3 ON period for output M3 285 = 1400mskdF Switch-on delay of sewing foot lifting 288 = 2550ms
Settings using parameter 198:Parameter 198 = 0 The signals hot thread chain cutting and sewing foot lift are enabled by means of pedal.Parameter 198 = 1 The signal hot thread chain cutting is enabled by means of knee switch and sewing foot lift by
means of pedal.Parameter 198 = 2 The signal hot thread chain cutting is enabled by means of pedal and sewing foot lift by means of
knee switch.
ST2/..
ST2/27
(M ST)30
ST2/32(M L)
M 6ST2/
M 5
(B R)M 3
in1...i10
- 2
(IM P)ST2/28
ST2/35
ST2/34
M 2
STV
FL
ST2/21
ST2/20
POS.2
n
POS.1
t3
2
SSc
n6
0 1
n2
- / 0
121
+- 1
0256/M ODE- 5a
kd3 kt3
t4 t5
kt2
n1
kdF
EFKA AB320A520035
Mode 4, 5, 6 or 7 (function “unlocking the chain” with light barrier)
Mark Function Parameter Control V810 V820Mode 5 290 = 5
drE Direction of motor rotation Clockwise 161 = 0Frd Reverse motor rotation 182 = 1
Basic position 2 On S5 key 4 key 7 keyEnd stitch condensing and thread trimmer *) OnLight barrier 009 = ONUnlock the chain automatically with light barrier 190 = 2
in7 Machine run blockage effective with open contact 246 = 6in8 Automatic speed n12 without pedal 247 = 10in.. Assign the function “unlocking the chain” to an output 2..n1 Positioning speed 110n2 Maximum speed 111n5 Speed after light barrier sensing 114t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204LS Light barrier compensating stitches 004ird Number of reversing increments 180drd Switch-on delay of reverse motor rotation 181tGn Speed gate damping period 222dGF Speed gate 2 224 = 1kdF Switch-on delay of sewing foot lifting 288
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!
ST2/35
ST2/34
ST2/32(M L)
(M ST)30ST2/
ENTK
LS
STV
M 5
M 6
FL t3
ST2/20
ST2/21
n
POS.2
POS.1
-
+- 2- 1 0
11/2
LS
n2
60 3 4 5
n5
7
t4 t5
n1
drd ird
n1
0256/ENTK- 1
EFKA AB320A5200 36
Mode 4, 5, 6 or 7 (function “unlocking the chain”)
Mark Function Parameter Control V810 V820Mode 5 290 = 5
drE Direction of motor rotation Clockwise 161 = 0Frd Reverse motor rotation 182 = 1
Basic position 2 On S5 key 4 key 7 keyEnd stitch condensing and thread trimmer *) On
in7 Machine run blockage effective with open contact 246 = 6in8 Automatic speed n12 without pedal 247 = 10in.. Assign the function “unlocking the chain” to an output 2..n1 Positioning speed 110n2 Maximum speed 111t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204ird Number of reversing increments 180drd Switch-on delay of reverse motor rotation 181tGn Speed gate damping period 222dGF Speed gate 2 224 = 1
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!
(MST)
ST2/34
ST2/32(ML)
30
ST2/35
ST2/
ENTK
M5
M6
FL
STV
t3
ST2/20
ST2/21
POS.2
POS.1
+
-
n
-2-1 0
11/2
n2 n1
drd Ird drd
n2 n1n1
0256/ENTK-2
Ird
n1
EFKA AB320A520037
Mode 6 (chainstitch with fast scissors) parameter 232 = 1
Mark Function Parameter Control V810 V820Mode 6 290 = 6Softstart 134 = 1Start stitch condensing On S2 key 1 key 1 keyChainstitch with fast scissors M3/M4 232 = 1
n2 Maximum speed 111n3 Start stitch condensing speed 112n6 Softstart speed 115n7 Trimming speed 116t1 Delay until speed release after stitch condensing 200t3 Start delay from lifted sewing foot 202c1 Stitch counting of start stitch condensing 001SSc Softstart stitches 100kd1/kd2 Delay times of outputs M1/M2 280/282kt1/kt2 ON periods of outputs M1/M2 281/283kd3/kd4 Delay times of outputs M3/M4 (AH1/AH2) 284/286kt3/kt4 ON periods of outputs M3/M4 (AH1/AH2) 285/287kdF Switch-on delay of sewing foot lifting 288
kt3(AH 1)
(AH 2)
M 3ST2/27
M 1
M 2
ST2/37
ST2/28
kd3
FL
ST2/35
ST2/34
STV
n
ST2/20
ST2/21
POS.1
POS.2
- 2
/
- 1 0
12
+
- 1
t1t3 c1
0 1
n6
2 3
SSc
n3
kd1 kt1
kd2
kd3
kt4kd4
kt2
kt3
kdF
n2 n7
SSc
t3
0
t1c1
1
n6
2 3
n3
kd1 kt1
kd4
kd2
kt4
kt2
n2 n7
kdF
AH
M 6ST2/
ST2/32M 5
M 4ST2/36
(M ST)30
(M L)
0256/M ODE- 6
EFKA AB320A5200 38
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 0 (seam end with stop)
Mark Function Parameter Control V810 V820Mode 7 290 = 7Counts c1, c2, c3 and c4 On S2/3 key 1/2 key 1/4 keySewing foot lifting at the seam end On S4 key 3 key 6 keyLight barrier 009 = 1Sequence “overlock mode with stop” 018 = 0Function “pedal in pos. –2” blocked 019 = 2Chain suction at the seam end until pedal in pos. 0 022 = 1Start blockage with light barrier uncovered 132 = 0Stitch counting at the start of the seam at fixed 143 = 0speed n3Stitch counting at the seam end at fixed speed n4 144 = 0Seam end after count c2 191 = 1Speed n5 after light barrier sensing 192 = 0Chain suction On after light barrier compensating 193 = 0stitchesTape cutter function 232 = 0
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start counting 112n4 Speed for end counting 113n5 Speed after light barrier sensing 114n7 Trimming speed 116c2 End counting for chain suction 000c1 Start counting for chain suction 001c3 Start counting for tape cutter 002c4 End counting for tape cutter 003LS Light barrier compensating stitches 004kLM Clamp at the seam end On 020 = 1ckL Run-out stitches clamp at the start of the seam 021kd1/kd2 Delay times of outputs M1/M2 280/282kt1/kt2 ON periods of outputs M1/M2 281/283kt3 ON period of tape cutter 285kdF Switch-on delay of sewing foot lifting 288
ST2/20
POS.1
+
-
n
0
- 2- 1 0
11/2
n2n3
4321 5 6 7 8
n1 n7
1
n2 n5
1 53 4
n4
2 3 4 5 6 7
M 1 c3
(M L)
(M ST)
ST2/32
ST2/30M 6
M 5
ST2/37
ST2/28
LS
M 2
<ckL
(FSPL)M 4
(AH )
ST2/36
ST2/27M 3
ST2/34
POS.2
ST2/35
ST2/21
FL
KS
ckLKLM kt3
SFS<SFS
t3
c1
c3 <c4 c2
c1
t3
kt3c4
LS
c2
kd1 kt1
0256/M ODE- 7a
kt2kd2
KLM
t4kdF t5
EFKA AB320A520039
Mode 7 (overlock) parameter 232 = 1 (fast scissors) / parameter 018 = 0 (seam end with stop)
Mark Function Parameter Control V810 V820Mode 7 290 = 7Counts c1, c2, c3 and c4 On S2/3 key 1/2 key 1/4 keySewing foot lifting at the seam end On S4 key 3 key 6 keyLight barrier 009 = 1Sequence “overlock mode with stop” 018 = 0Function “pedal in pos. –2” blocked 019 = 2Chain suction at the seam end until pedal in pos. 0 022 = 1Start blockage with light barrier uncovered 132 = 0Stitch counting at the start of the seam at fixed 143 = 0speed n3Stitch counting at the seam end at fixed speed n4 144 = 0Seam end after count c2 191 = 1Speed n5 after light barrier sensing 192 = 0Chain suction On after light barrier compensating 193 = 0stitchesFunction “fast scissors” 232 = 1
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start counting 112n4 Speed for end counting 113n5 Speed after light barrier sensing 114n7 Trimming speed 116c2 End counting for chain suction 000c1 Start counting for chain suction 001c3 Start counting for tape cutter 002c4 End counting for tape cutter 003LS Light barrier compensating stitches 004kLM Clamp at the seam end Off 020 = 0kd1 Delay time of output M1 280kd2 Delay time of output M2 282 = 0kt1/kt2 ON periods of outputs M1/M2 281/283kt3 ON period of tape cutter 285kdF Switch-on delay of sewing foot lifting 288
ST2/32
ST2/30M 6
M 5 (M L)
(M ST)
0
POS.2
ST2/36
ST2/37
ST2/27
ST2/28
ST2/21
ST2/35
ST2/34
LS
M 3
M 2
M 1
M 4
FL
KS
(AH 1)
(AH 2)
(FSPL)
t3
ST2/20
POS.1
-
- 1+- 2
n
0
11/2
kt3c3
c1
n2n3
4321 5 6 7 8
n1
0256/M ODE- 7c
t3 LS
kt2
<
c4
c4 c2
c2
5
n2
1
n5
3 4 1
n4
2 3 4 5 6 7
kt1kd1
t4kdF t5
n7
EFKA AB320A5200 40
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 1 (seam end without stop)
Mark Function Parameter Control V810 V820Mode 7 290 = 7Counts c1, c2, c3 and c4 On S2/3 key 1/2 key 1/4 keyLight barrier compensating stitches 004 = 0Light barrier 009 = 1Sequence “overlock mode at the seam end without stop” 018 = 1Function “pedal in pos. –1/–2” activated in the seam 019 = 3Chain suction at the seam end until pedal in pos. 0 022 = 1Stitch counting at the start of the seam at fixed 143 = 0speed n3Stitch counting at the seam end at fixed speed n4 144 = 0Tape cutter function 232 = 0
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start counting 112n7 Trimming speed 116t3 Start delay from lifted sewing foot 202c1 Start counting for chain suction 001c3 Start counting for tape cutter 002c4 End counting for tape cutter 003kd1/kd2 Delay times of outputs M1/M2 280/282kt1/kt2 ON periods of outputs M1/M2 281/283kt3 ON period of tape cutter 285kdF Switch-on delay of sewing foot lifting 288
(M L)
(M ST)
ST2/32
ST2/30
(AH )
ST2/37
ST2/36
ST2/27
ST2/28
M 6
LS
M 5
M 3
M 2
M 1
(FSPL)
ST2/20
ST2/21
ST2/35
ST2/34
M 4
FL
POS.1
POS.2
K S
+
-
n
t3
- 2- 1 0
11/2
kt3c3 kt3c4
n3 n2
0 1 2 3 4 65
c1
n4
1 2 3 4 65 7
kt3c3
n2n3
50 1 2 3 4 6
c1
n1 n7
kd1 kt1
kd2 kt2
t4kdF t5
0256/M ODE- 7b
EFKA AB320A520041
Mode 8 (backlatch Pegasus)
Mark Function Parameter Control V810 V820Mode 8 290 = 8Basic position 2 On S5 key 4 key 7 key
SSt Softstart 134 = 1in1 Machine run blockage activated with open switch 240 = 6in3 n-Auto with closed switch 242 = 10n1 Positioning speed 110n2 Maximum speed 111n6 Softstart speed 115n12 Automatic speed 118t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204SSc Softstart stitches 100
*) When automatic speed is On, machine run blockage (safety switch) does not work!NA Start of seamNE Seam end
n1
(LSP)in1
ST2/7
0256/M ODE- 8 NA
ST2/30
ST2/32
/PEDST2/27
/PED
ST2/35
/PEDST2/28
ST2/37
ST2/6
M 6
M 5
in3
M 3
M 1
FL
M 2
(n12)
(M ST)
(M L)
+ 1
- 1
+ 1
POS.1
POS.2
ST2/20
ST2/21
-
n
- 2- 1 0
121/
+
20 1
n6
SSc
n2 n12
NE NA NE
n2
SSc
0 1 2
n6
t4 t5
n1
EFKA AB320A5200 42
Mode 9 (backlatch Yamato)
Mark Function Parameter Control V810 V820Mode 9 290 = 9Basic position 2 On S5 key 4 key 7 key
SSt Softstart 134 = 1in1 Machine run blockage activated with open switch 240 = 6in3 Automatic speed with open switch 242 = 10
(the function of input 3 is inverted in mode 9)n1 Positioning speed 110n2 Maximum speed 111n6 Softstart speed 115n12 Automatic speed 118t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204SSc Softstart stitches 100
*) With this setting, machine run blockage (safety switch) takes priority over automatic speed!
(LSP)
ST2/6
ST2/8
ST2/7
0256/M ODE- 9
in3
in4
(n12)
(n9)
NE
SSc
ST2/32
ST2/30
/PEDST2/37
/PED
/PEDST2/27
ST2/28
POS.2
ST2/21
ST2/35
M 5
M 6
in1
M 3
M 2
M 1
FL
(M L)
(M ST)
+ 1
+ 1
- 1
POS.1ST2/20
- 0
- 2
n
- 1+
0
11/2
n12
1
n6
2
n2 n1
NA NANE
SSc
t3
1
n6
0 2
n9n2 n1
EFKA AB320A520043
Mode 10 (lockstitch)
Mark Function Parameter Control V810 V820Mode 10 290 = 10Single start backtack On S2 key 1 key 1 keySingle end backtack On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204t6 Thread wiper ON period 205t7 Sewing foot switch-on delay after thread wiper 206dFW Switch-on delay of the thread wiper 209t10 Full power of thread trimmer backward 212t11 Holding power output “stitch condensing” of the thread 213
trimmer backwardc1 Start backtack stitches backward 001c3 End backtack stitches backward 002
t10 t11
(FW )
(FA- R)
(FA- V)
(FSPL)
STVST2/34
M 2ST2/28
M 1ST2/37
t6dFw
t7
M 4ST2/36
n
POS.1
POS.2
FL
ST2/20
ST2/21
ST2/35
n3
c1
0 1 2 3
t3
4 5 6 7
t1
n2 n4
c3
n1
0 1 2 3 4 5
n7
- 2- 1 0
11/2
+
-
t4 t5
M 6ST2/30
ST2/32
M 3
M 5
ST2/27
(M ST)
(M L)
0256/M ODE- 10
EFKA AB320A5200 44
Mode 14 (lockstitch)
Mark Function Parameter Control V810 V820Mode 14 290 = 14Double start backtack with stitch correction On S2 key 1 key 1 keyDouble end backtack with stitch correction On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204t6 Thread wiper ON period 205t7 Sewing foot switch-on delay after thread wiper 206t8 Start backtack stitch correction 150t9 End backtack stitch correction 151c2 Start backtack stitches forward 000c1 Start backtack stitches backward 001c3 End backtack stitches backward 002c4 End backtack stitches forward 003kd4 Delay time output M2 286kt4 ON period output M2 287
- / 0
121
(FA1+ 2)
(FA2)M 4
(M ST)30
ST2/32(M L)
ST2/36
ST2/M 6
M 5
(FW )ST2/27
ST2/37
ST2/28(FZ)
M 1
M 3
M 2
ST2/20
ST2/35
ST2/34
ST2/21
VR
FL
POS.2
n
+
POS.1
- 1- 2
t8
c2
t3 t1
c1
310
n3
2 3 1 2
0256/M ODE- 14
t7
kd4
c3
n2n1n2
0
t6t9
c4
1
n4
2 1 2
n7
3
kt4
t4 t5
EFKA AB320A520045
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier covered
Mark Function Parameter Control V810 V820Mode 15 290 = 15Tape cutting On 2 key 4 keyCounts c1 and c2 On S2/3 key 1 key 1/5 keyBasic position 2 On S5 key 4 key 7 keyLight barrier 009 = 1Speed of the light barrier compensating stitches 192 = 1depending on the pedal
in4 Key for high lift for walking foot operational mode stored 243 = 14in5 Key for manual tape cutter 244 = 15n1 Positioning speed 110n2 Maximum speed 111c2 Stitch counting until thread tension release Off 000c1 Stitch counting until thread tension release On 001LS Light barrier compensating stitches 004t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204kdF Delay time until sewing foot lifting On 288kt6 *) Delay time of output VR (chain suction) 256c7 Start counting until tape cutter M4 On 257c8 End counting until tape cutter M4 On 258kt4 *) ON period of tape cutter M4 287
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10corresponds to 100ms.
ST2/35
FL t3
ST2/20
ST2/21
n
POS.2
POS.1
+
-
0
- 2- 1
121/
n2
t5LS t4kdF
31 4 5 6 7
n1
(AH )
ST2/8
ST2/5
in5
(H P)in4
(M L)
ST2/32
ST2/30
(H P)M 6
M 5
LS
ST2/27
ST2/34
ST2/36
(AH )
(KS)
M 4
VR
(KB )M 1
(FSPL)
(KS)
ST2/28
ST2/37
M 2
M 3
c7 kt4
kt6
c1
0256/M ODE- 15a
c8 kt4
c2
kt4
EFKA AB320A5200 46
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrieruncovered
Mark Function Parameter Control V810 V820Mode 15 290 = 15Tape cutting On 2 key 4 keyCounts c1 and c2 On S2/3 key 1 key 1/5 keyBasic position 2 On S5 key 4 key 7 keyLight barrier 009 = 1Speed of the light barrier compensating stitches 192 = 1depending on the pedal
in4 Key for high lift for walking foot operational mode stored 243 = 14(M6 inverted)
in5 Key for manual tape cutter 244 = 15n1 Positioning speed 110n2 Maximum speed 111c2 Stitch counting until thread tension release Off 000c1 Stitch counting until thread tension release On 001LS Light barrier compensating stitches 004t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204kdF Delay time until sewing foot lifting On 288kt6 *) Delay time of output VR (chain suction) 256c7 Start counting until tape cutter M4 On 257c8 End counting until tape cutter M4 On 258kt4 *) ON period of tape cutter M4 287
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10corresponds to 100ms.
**) Programming is possible at intermediate stop before tape cutting at the start of the seam!
ST2/35
FL t3
ST2/20
ST2/21
n
POS.2
POS.1
+
-
0
- 2- 1
121/
n1n2 n1
LS
n2
31 4 5 6 7
t5t4kdF
ST2/32
ST2/30
ST2/8
ST2/5
in4
M 6
in5
ST2/34
ST2/28
ST2/27
ST2/36
ST2/37
M 5
LS
M 4
VR
M 2
M 3
M 1
(H P)
(AH)
(M L)
(H P)**)
(AH)
(KS)
(KS)
(FSPL)
(KB )
c7 kt4
kt6
c1
0256/M ODE- 15c
kt4c8
c2
kt4
EFKA AB320A520047
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is On
Mark Function Parameter Control V810 V820Mode 15 290 = 15Tape cutting On 2 key 4 keyCounts c1 and c2 On S2/3 key 1 key 1/5 keyBasic position 2 On S5 key 4 key 7 keyLight barrier 009 = 1Speed of the light barrier compensating stitches 192 = 1depending on the pedal
in4 Key for high lift for walking foot operational mode stored 243 = 14in5 Key for manual tape cutter 244 = 15n1 Positioning speed 110n2 Maximum speed 111c2 Stitch counting until thread tension release Off 000c1 Stitch counting until thread tension release On 001c3 Counting for chain suction 002c4 Counting for chain blowing 003LS Light barrier compensating stitches 004ckL Counting after light barrier uncovered until tape cutter On 021t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204kdF Delay time until sewing foot lifting On 288kd1 *) Delay time of output M1 and M2 280kt1 *) ON period of output M1 and M2 281kd2 *) Delay time of output ST2/34 282kt2 *) ON period of output ST2/34 283kd4 *) Delay time of output M4 (tape cutter) 286kt4 *) ON period of tape cutter M4 (tape cutter) 287
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10corresponds to 100ms.
c4
ST2/37
ST2/35
(KB )
FL
M 1
t3
ST2/20
ST2/21
n
POS.2
POS.1
+
-
0
- 2- 1
121/
LS
3
n2
1 4 5 6 7
n1
kd4
kt1
t5kdF t4
kt1
(M L)
ST2/32
(H P)
ST2/30
(H P)
(AH )
(KS)
(KS+ KB )
(FSPL)
ST2/34
ST2/28
ST2/27
ST2/36
(AH )
M 5
ST2/5
in5
ST2/8
in4
M 6
LS
VR
M 4
M 2
M 3 c1
c3
kd2
c2
kt4ckL
0256/M ODE- 15b
kd2kt2 kd1
kt4 kt4
kd1kt2
kd4 kt4
EFKA AB320A5200 48
Mode 16 (feed-off-the-arm machine) without automatically unlocking the chain with tape cutter (232 = 0)
Mark Function Parameter Control V810 V820Mode 16 290 = 16Counts c1, c3 and c4 On S2/3 key *) 1/2/4 keyBasic position 2 On S5 key *) 0 keySewing foot lifting at the seam end On S4 key *) 9 keyLight barrier 009 = 1Sequence “overlock mode with stop” 018 = 0Function “pedal in pos. –2” blocked 019 = 2Start blockage with light barrier uncovered 132 = 0Stitch counting at the start of the seam at fixed 143 = 0speed n3Stitch counting at the seam end at fixed speed n4 144 = 0Seam end after count c2 191 = 0Speed of the light barrier compensating stitches 192 = 0depending on the pedalBlow fabric onto stack M7 from light barrier uncovered 194 = 1onwards
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start counting 112n4 Speed for end counting 113n5 Speed after light barrier sensing 114n7 Trimming speed 116c1 Start counting for chain suction 001c3 Start counting for tape cutter 002c4 End counting for tape cutter 003LS Light barrier compensating stitches 004kd2 Delay time of output M2 282kt2 ON period of output M2 283kt3 ON period of tape cutter 285kdF Switch-on delay until sewing foot lifting On 288kt5 Switch-off delay “blow fabric onto stack at the seam end” 289
*) The V810 control panel cannot be used for the functions in mode 16!
LS
(STB )
M 5 (M L)ST2/32
ST2/23M 7
n3
2
c3
(FSPL)ST2/36
ST2/37
ST2/28M 2
M 3 (AH )ST2/27
M 1 (RB )
POS.2
M 4
ST2/34
ST2/35
ST2/21
KS
FL t3
- 2- 1 0/
ST2/20
POS.1
n
+
- 1
0 1
12
kt3
c1
t3
43 5 6 7 8
n2 n1
0256/M ODE- 16
kt5
LS
c4 kt3
2
n2 n5
1 3 4 15 7
n4
3 4 5 6
n7
kd2 kt2
kdF t5t4
EFKA AB320A520049
Mode 16 (feed-off-the-arm machine) automatically unlocking the chain with tape cutting / 8 key on V820On
Mark Function Parameter Control V810 V820Mode 16 290 = 16Counts c4 On S2/3 key *) 1/2/4 keyBasic position 1 On S5 key *) 0 keyUnlock the chain with chain blowing in opposite On *) 8 keydirectionLight barrier 009 = 1Sequence “overlock mode with stop” 018 = 0Function “pedal in pos. –2” blocked 019 = 2Start blockage with light barrier uncovered 132 = 0Stitch counting at the seam end at fixed speed n3 143 = 0Stitch counting at the seam end at fixed speed n4 144 = 0Speed n5 after light barrier sensing 192 = 0Blow fabric onto stack M7 from light barrier uncovered 194 = 1onwards
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start counting 112n4 Speed for end counting 113n5 Speed after light barrier sensing 114n7 Trimming speed 116c4 End counting for tape cutter 003LS Light barrier compensating stitches 004ird Number of reversing increments 180drd Switch-on delay of reverse motor rotation 181c6 Number of run-out stitches when unlocking the chain 184kd1 Delay time of output M1 280kt1 ON period of output M1 281
*) The V810 control panel cannot be used for the functions in mode 16!
n2
ST2/20
n
POS.1
POS.2
+
-
- 2- 1 0
11/2
n1n2
drd
n4
3
n5
1 3 4 15 2
n7
4 5 321
ird
ST2/37
M 5 (M L)ST2/32
ST2/23M 7 (STB )
ST2/28
LS
M 2
ST2/34
ST2/36
ST2/27M 3
M 1
M 4
(AH )
(RB )
(FSPL)
KS
ST2/35
ST2/21
FL t3
0256/ M O DE- 16a
t3 LS
c4 kt3
c6
kt1kd1
t4 t5
EFKA AB320A5200 50
Mode 17 (stitch lock Pegasus)
Mark Function Parameter Control V810 V820Mode 17 290 = 17Basic position 2 On S5 key 4 key 7 keyThread trimmer and thread wiper On S3 key 5 key
n1 Positioning speed 110n2 Maximum speed 111n7 Trimming speed 116dr° Stop for thread trimming depending on angle 197t3 Start delay from lifted sewing foot 202kd1 Delay time of the top cover thread cutter LFA 280kt1 ON period of the top cover thread cutter LFA 281kd2 Delay time of the thread trimmer FA 282kt2 ON period of the thread trimmer FA 283kd3 Delay time of the stitch lock function STS 284kt3 ON period of the stitch lock function STS 285kdF Switch-on delay until sewing foot lifting On 288
kdF
kt1
ST2/32
M L
n
ST2/35
ST2/27
ST2/28
POS.1
ST2/20
ST2/21
POS.2
ST2/34
FL
M 3
M 2
VR
t3
(STS)
(LFA)
(FA)
-
- 2
/
- 1 0
12
+
1
n2 n7 n7
kd3 kt3
kd2
kd1
dr
0256/M ODE- 17
kt3
n2 n1
t3
kt2
kd3
n7
kt2
kt1
kd2
kd1
dr
EFKA AB320A520051
Mode 20 (lockstitch Juki LU1510-7)
Mark Function Parameter Control V810 V820Mode 20 290 = 20Double start backtack On S2 key 1 key 1 keyDouble end backtack On S3 key 2 key 4 keyReverse motor rotation 182 = 1
in3 Speed limitation bit 0 242 = 31in4 Speed limitation bit 1 243 = 32n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116n9 Automatic speed 122n10 Automatic speed 117n11 Automatic speed 123t1 Delay until speed release after start backtack 200t3 Start delay from lifted sewing foot 202t7 Sewing foot switch-on delay after thread wiper 206ird Number of reversing increments 180drd Switch-on delay of reverse motor rotation 181iFA Activation angle of the thread trimmer 250FSA Thread tension release ON period 251FSE Thread tension release delay depending on angle 252c2 Start backtack stitches forward 000c1 Start backtack stitches backward 001c3 End backtack stitches backward 002c4 End backtack stitches forward 003
0
ST2/6
ST2/8
ST2/37
ST2/28
ST2/34
ST2/35
ST2/21
M 2
in4
in3
M 1
VR
FL
(FSPL)
(B IT1)
(B IT0)
(FA)
t3
ST2/20
POS.1
POS.2
-
- 2
n
/ 0
121
+- 1
c2 t1c1
11 2 3 2 3
n3 n2 n11 n9
c3
FSE
iFA
c4
1
n2n10
0 2 21
n7n4
3
0256/M ODE- 20
FSA
t7
drd ird
EFKA AB320A5200 52
Mode 21 (stitch lock)
Mark Function Parameter Control V810 V820Mode 21 290 = 21Stitch lock function 196 = 1Start stitch condensing On S2 key 1 key 1 keyEnd stitch condensing On S3 key 2 key 4 key
n1 Positioning speed 110n2 Maximum speed 111n3 Speed for start stitch condensing 112n4 Speed for end stitch condensing 113n7 Trimming speed 116t1 Delay until speed release after stitch condensing 200t3 Start delay from lifted sewing foot 202t4 Full power of sewing foot lifting 203t5 Pulsing of sewing foot lifting 204tFA Stop time for drive 253kd1 Delay time thread trimmer 280kt1 ON period thread trimmer 281kd2 Delay time stitch lock 282kt2 ON period stitch lock 283kd3 Delay time thread wiper 284kt3 ON period thread wiper 285kdF Switch-on delay until sewing foot lifting On 288c1 Counting start stitch condensing 001c3 Counting end stitch condensing 002
n
+
-
- 2
/
- 1 0
121
n2n3 n1
c3
1
n4 n7 n7
(FW )
(FA)
(M L)
(STV)
(STS)
ST2/27
ST2/32M 5
M 2
ST2/37
ST2/34
ST2/28
M 3
M 1
STV
ST2/35
FL
ST2/20
ST2/21
POS.1
POS.2
c1t3
0 1
t1
32
t4 t5 t3
0
0256/M ODE- 21
kd1
kt2kd2
32
tFA
kd3 kt3
kt1
kdF
EFKA AB320A520053
Mode 23 (lockstitch)
Mark Function Parameter Control V810 V820Mode 23 290 = 23Double start backtack On S2 key 1 key 1 keyDouble end backtack On S3 key 2 key 4 keyHigh lift for walking foot 137 = 1
n2 Maximum speed 111n3 Start backtack speed 112n4 End backtack speed 113n7 Trimming speed 116n10 High lift walking speed 117t6 Thread wiper ON period 205t7 Sewing foot switch-on delay after thread wiper 206iFA Activation angle of the thread trimmer 250FSA Thread tension release ON period 251FSE Thread tension release delay depending on angle 252tFA Stop time for thread trimmer 253c2 Start backtack stitches forward 000c1 Start backtack stitches backward 001c3 End backtack stitches backward 002c4 End backtack stitches forward 003tHP High lift walking speed run-out time 152cHP Stitch counting high lift for walking foot 185
*) If the key is pressed down longer than the cHP count, high lift for walking foot remains On as well. If the keyis pressed briefly, high lift for walking foot is On during counting, as shown in the timing diagram.
n2
(H P)M 5
(H P)in1
ST2/7
M 11(LH P)
ST2/31
ST2/32
(FW )ST2/27
(M L)
ST2/28
M 2
(FSPL)M 4
ST2/36
M 3
ST2/37
(FA)
ST2/35
ST2/34
M 1
VR
POS.2
ST2/21
FL
ST2/20
c2 c1
t3 t1
n
POS.1
- / 021
+ - 2- 1
1
10
n3
2 3 1 2 3
0256/M ODE- 23
cH P tH P
FSE
c3
iFA
c4
tFA
n2n10
654321 7 0 1 2
n4
1 2
n7
3
n7
FSA
t6
t7
EFKA AB320A5200 54
Mode 24 (Pegasus MHG-100) “bottom hemming“ On
Mark Function Parameter Control V810 V820Mode 24 290 = 24Basic position 2 On S5 key 4 key 7 keyLight barrier 009 = 1
n1 Positioning speed 110n2 Maximum speed 111n5 Light barrier speed 114n7 Trimming speed 116LS Light barrier compensating stitches 004dnL Delay time until light barrier speed release 158kd2 Delay time of the thread trimmer M1 and M2 282kt2 ON period of the thread trimmer M1 and M2 283kd3 Delay time of the thread wiper M3 284kt3 ON period of the thread wiper M3 285kdF Switch-on delay until sewing foot On 288
Outputs: Inputs:FL = Sewing foot lifting in1 = Machine run blockage Pa. 240= 6M1/M2 = Thread trimmer in2 = Switch bottom/sleeve hemming Pa. 241=13M3 = Thread wiper in3 = Sensor input Pa. 242=28M7 = Hemming guide in4 = Knee switch “hemming guide” Pa. 243=22M8 = Hemming blow 1M9 = Hemming blow 2M6 = Display “bottom/sleeve hemming”
n
ST2/20
ST2/21
POS.1
POS.2
+
-
- 2- 1 0
11/2
Power on
n2 n1 n2 n1
5
n5n2
30 4 6
n7
M 8
in2
ST2/11
in4
ST2/8
in3 (SEN)
ST2/6
ST2/25
ST2/24
M 9
ST2/27
ST2/23
M 7
ST2/28
M 3 (FW )
ST2/35FL
ST2/37
M 2
M 1
(FA)
(FA)
0256/M ODE- 24
kt3
dnL
kd3
LS
kt2kd2
kdF
EFKA AB320A520055
Mode 24 (Pegasus MHG-100) “sleeve hemming“ On
Mark Function Parameter Control V810 V820Mode 24 290 = 24Basic position 2 On S5 key 4 key 7 keyLight barrier 009 = 1
n1 Positioning speed 110n2 Maximum speed 111n5 Light barrier speed 114n7 Trimming speed 116LS Light barrier compensating stitches 004dnL Delay time until light barrier speed release 158cb2 Stitches until signal M9 “hemming blow 2” Off 159kd2 Delay time of the thread trimmer M1 and M2 282kt2 ON period of the thread trimmer M1 and M2 283kd3 Delay time of the thread wiper M3 284kt3 ON period of the thread wiper M3 285kdF Switch-on delay until sewing foot On 288
Outputs: Inputs:FL = Sewing foot lifting in1 = Machine run blockage Pa. 240= 6M1/M2 = Thread trimmer in2 = Switch bottom/sleeve hemming Pa. 241=13M3 = Thread wiper in3 = Sensor input Pa. 242=28M7 = Hemming guide in4 = Knee switch “hemming guide” Pa. 243=22M8 = Hemming blow 1M9 = Hemming blow 2M6 = Display “bottom/sleeve hemming”
n
ST2/20POS.1
+
-
- 2- 1 0
11/2
Power on
n2 n1 n1n2
5
n5n2
30 4
n7
6
ST2/23
(SEN)in3
ST2/11
ST2/6
in2
in4
ST2/8
ST2/24
ST2/25M 9
M 8
(FA)
(FW )
(FA)
ST2/37
ST2/27
ST2/28
M 7
M 3
M 2
POS.2
ST2/35FL
M 1
ST2/21
0256/M ODE- 24a
kdF
cb2
kd3
dnL
LS
kd2kt2
kt3
EFKA AB320A5200 56
6 List of Parameters
6.1 Preset Values Depending on Mode
The preset values which are different in the various modes are listed in the table below. When switching the mode bymeans of parameter 290, these values change automatically.
Operator Level
Mode !!!!0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24Parameter
000 - - - - - - - - - - - 6 30 - - - - -001 - - - 2 - - - - - 2 - 2 17 - - - - -002 - - - - - - - - - - - 10 2 - - - 3 -003 - - - - - - - - - - - 10 18 - - - 3 -004 - - - - - - 0 - - - - 25 0 - - - - 35005 - - - 0 - - - - - - - - - - - - 0 -007 - - - - - - - - - - - - - - - - 10 -008 - - - - - - 4 - - - - - - - - - 2 -009 - - - - - - 1 - - - - 1 1 - - - - 1013 - - - - - - - 0 0 - - 0 - - - - - -014 - 0 - - - - 0 0 0 - - 0 0 - 0 - 0 -019 - - - - - - 2 - - - - 2 2 1 - - - 3021 - - - - - - - - - - - 23 - - - - - -
Technician Level
Mode !!!! 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24Parameter
100 - - - - - - - - - 1 - - - - - - - -** 110 - - - 180 - - - 250 250 180 - - - - - - 180 -** 111 - - - 5000 - - - - - 4500 - 7500 3800 - 2500 5500 4800 5000** 112 - - - - - - - - - - - - 3800 - 600 - 1700 -** 113 - - - - - - - - - - - - 3800 - 600 - 1700 -** 114 - - - - - - - - - - - - - - - - 1700 2000** 115 - - - - - - - - - 700 - - - - - - 800 -** 116 - - - - - - - - - - - - - - - - 180 -** 117 - - - - - - - - - - - 9900 - - 1800 - 2000 9900** 118 - - - - - - - - - - - - - - 2500 - 3000 -
119 - - - - - - - - - - - - 1 - - - -** 122 - - - - - - - - 6000 - - - - - - - - -** 123 - - - - - - - - - - - - - - 2400 - - 9900
130 - - - - - - 1 - - - - - 1 - - - - -131 - - - - - - - - - - - 1 - - - - - -132 - - - - - - 0 - - - - 0 0 - - - - 0134 - - - - - - - - - 1 - - - - 1 - 1 -135 - - - - - - - - - - - - - - 1 - - -137 - - - - - - - - - - - - - - - 1 1 1152 - - - - - - - - - - - - - - - - 100 -153 - - - - - - - - - - 0 - - - - - 06 -158 - - - - - - - - - - - - - - - - - 100161 - - - 0 0 0 0 0 0 0 - 0 0 0 - 0 - 0180 - - - - - - - - - 14 - - - - 45 - 14 -181 - - - - - - - - - 230 - - - - - - 0 -182 - - - - - - 1 - - 1 - - 1 - 1 - - -184 - - - - - - - - - - - - - - - - - -190 - - - 0 - - 2 - - - - - 1 - - - - -192 - - - - - - 1 - - - - 1 1 - - - - -194 - - - - - - - - - - - - 1 - - - - -196 - - - - - - - - - - - - - - - - 0 -197 - - - - - - - - - - - - - 360 - - - -
x = The positions marked with ”x“ are not used in the functional sequence!- = For the positions marked with “-“ the preset values listed in the List of Parameters are used !** = When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520057
Supplier LevelMode !!!! 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24Parameter
200 - - - - - - - - - - - - - - - - 50 -201 - - - 160 - - - - - - - - - - - 200 - -202 - - - - - - - 0 0 - - - - - - - 80 -203 - - - 350 - - - - - - - - - - - - 200 -204 - - - - - - - - - 12 - - - - - - - -
** 205 - - - - - - - - - 240 - - - - - - 100 -206 - - - - - - - - - 150 - - - - - - 50 -207 - - - - - - - - - - - - - - - - 10 -209 - - - - - - - - - 100 - - - - - - - -210 - - - - - - - - - - - - - - - - 100 -211 - - - - - - - - - - - - - - - - 0 -212 - - - 100 - - - - - 100 - - - - - - - -213 - - - - - - - - - 12 - 100 - - - - 50 -234 - - - - - - - 0 0 - - - - - - - - -240 - - - 6 - - - 6 6 - - - 15 - 13 - 13 6241 - - - - - - - - - - 16 - - - - - 07 14242 - - - 3 - - - 10 38 - - - - - 31 - 01 28243 - - - - - - - 1 34 - - 14 15 - 32 - 0 22244 - - - - - - - - - - - 15 - - - - 16 -245 - - - - - - - 12 12 - - - - - 16 - 0 -246 - - - - - - - - - - - - - - 13 - 33 -247 - - - - - - - - - - - - - - - - 11 -248 - - - - - - - - - - - - - - - 14 28 -249 - - - - - - - - - - - - - - - - 17 -250 - - - - - - - - - - - - - - - - 400 -
** 253 - - - - - - - - - - - - - - 0 - 0 -255 - - - 25 - - - - - 25 - - - - - - - -260 - - - - - - - - - - - - - - - 100 - -262 - - - - - - - - - - - - - - - 20 - -269 - - - - - - - - 25 - - - - - - - - -270 - - - - - - - - 1 - 3 - - - - 1 - -271 - - - - - - - - - - 200 - - - - 4 - -272 - - - - - - - - - - - - - - - - - -
** 274 - - - - - - - - - - - - 0 - - - - -** 275 - - - - - - - - - - - - 100 - - - - -** 280 x x x 100 - - 100 x x x - 10 - 100 - x - 100** 281 - - - - - - - - - 280 - 50 1000 - - 250 - -** 282 x 0 x 0 - - 200 x x x x 30 200 - - 40 - -** 283 - - - 200 - - - - - - - 100 - - - 80 - -** 284 x x x - - 0 0 x x 150 x - 0 - - 300 - 230** 285 x x x - - - - x x 70 x - - 70 - 680 - -** 286 x x x x - 0 0 x x x x 100 0 - - - - -** 287 x x x x - - 0 x x x x 50 0 - - - 0 -** 288 x x x - - - - x x x x - - 200 - - - -
291 - - - - 5 5 8 7 7 - - 7 7 5 - 5 - 5292 - - - - 3 3 5 5 5 - - 5 7 3 - 3 - 3293 - - - - - - - - - - - - - - - - - -294 - - - - - - - - - - - 14 - - - - - -
Further Functions Switchable by Means of the Control KeysMode !!!! 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24
Basic pos. 1 1 1 1 2 2 2 2 2 1 1 2 2 2 1 1 1 2Single OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFFstartbacktackDouble ON ON ON OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON ON ON OFFstartbacktackSingle OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFFendbacktackDouble ON ON ON OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON ON ON OFFendbacktack
NoteThe preset values of the following list of parameters refer to the setting of parameter 290 = 0.
x = The positions marked with ”x“ are not used in the functional sequence!- = For the positions marked with “-“ the preset values listed in the List of Parameters are used !** = When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A5200 58
6.2 Operator Level
The preset values of the following list of parameters refer to the setting of parameter 290 = 0.
Parameter Designation Unit max min Preset Ind.000 c2 - Number of stitches of start backtack forward stitches 254 0 2 *) A
- Number of stitches of start stitch condensing without stitch regulator- Number of stitches of end counting “chain suction”
001 c1 - Number of stitches of start backtack backward stitches 254 0 4 *) A- Number of stitches of start stitch condensing with stitch regulator- Number of stitches of start counting “chain suction”
002 c3 - Number of stitches of end backtack backward stitches 254 0 2 *) A- Number of stitches of end stitch condensing with stitch regulator- Number of stitches of tape cutter at the start of the seam
003 c4 - Number of stitches of end backtack forward stitches 254 0 2 *) A- Number of stitches of end stitch condensing without stitch regulator- Number of stitches of tape cutter at the seam end
004 LS Light barrier compensating stitches stitches 254 0 7 *) A005 LSF Number of stitches of the light barrier filter for stitches 254 0 1 A
knitted fabrics006 LSn Number of light barrier seams 15 1 1 *) A007 Stc Number of stitches for the seam with stitch stitches 254 0 20 A
counting008 -F- A parameter from the technician level is assigned to 5 1 1 *) A
the 9 key on the V820 control panel1 = Softstart On/Off2 = Ornamental backtack On/Off3 = Sewing start blocked with light barrier uncovered
On/Off4 = Unlocking the chain On/Off5 = Signals A1 and/or A2 On/Off with slide-in strips
1...4 (lefthand arrow = A1, righthand arrow = A2)009 LS Light barrier On/Off 1 0 0 *) A013 FA Thread trimmer On/Off 1 0 1 *) A014 FW Thread wiper On/Off 1 0 1 *) A015 StS Stitch counting On/Off 1 0 0 A018 UoS 0 = Sequence “overlock mode with stop” 3 0 0 A
1 = Sequence “overlock mode without automaticstop. When the command “run” is given, thedrive runs at the preselected speed. Withpedal in pos. 0 or light barrier covered, theprogram switches to the next start of a seamwithout issuing signals M1/M2.
2 = As with setting “1”. But with pedal in pos. 0signals M1/M2 will be issued, and the programswitches to the next start of a seam.
3 = As with setting “1”. But with pedal in pos. -2signals M1/M2 will be issued, and the programswitches to the next start of a seam. Inter-mediate stop and sewing foot lift with pedalin pos. –1 are possible.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA AB320A520059
Operator Level
Parameter Designation Unit max min Preset Ind.019 -Pd 0 = Pedal in pos. –1 disabled in the seam. With pedal in 4 0 3 *) A
pos. –2 in the seam, only sewing foot lifting ispossible. (Function only if parameter 009 = 1)
1 = Pedal in pos. –1, sewing foot lifting disabled in theseam.
2 = Pedal in pos. –2, thread trimming disabled.(Function only if parameter 009 = 1)
3 = Pedal in pos. –1 and –2 enabled in the seam.4 = Pedal in pos. –1 and –2 blocked in the seam.
(Function only if parameter 009 = 1)020 kLM Clamp at the seam end On/Off 1 0 0 A021 ckL Run-out stitches clamp at the start of the seam stitches 254 0 2 *) A022 SPo 0 = Chain suction until the end of count c2 1 0 0 A
1 = Chain suction at the seam end until pedal inpos. 0 (neutral)
023 AFL Automatic sewing foot lifting with pedal forward 1 0 1 Aat the seam end, if light barrier or stitch counting is On0 = Automatic sewing foot Off1 = Automatic sewing foot On
030 rFw 0 = Bobbin thread monitor Off 2 0 0 A1 = Bobbin thread monitor with stop2 = Bobbin thread monitor without stop
031 cFw Number of stitches for bobbin thread monitor stitches 25500 ***) 0 0 A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!***) When programming the 5-digit (max) parameter values on the control or control panel, the 3-digit value displayed
must be multiplied by 100.
EFKA AB320A5200 60
6.3 Technician Level
Code no. 190 with control operationCode no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.100 SSc Number of softstart stitches stitches 254 0 2 *) A110 n1 Positioning speed RPM 390 **) 70 200 *) A111 n2- Upper limit setting range of the maximum speed RPM 9900 **) n2_ 4000 *) A112 n3 Start backtacking speed RPM 9900 **) 200 1200 *) A113 n4 End backtacking speed RPM 9900 **) 200 1200 *) A114 n5 Speed after light barrier sensing RPM 9900 **) 200 1200 A115 n6 Softstart speed RPM 1500 **) 70 500 *) A116 n7 Trimming speed RPM 500 **) 70 200 *) A117 n10 High lift walking speed RPM 9900 **) 400 1000 *) A118 n12 Automatic speed for stitch counting RPM 9900 **) 400 3500 *) A119 nSt Speed stage graduation 3 1 2 *) A
1 = linear2 = slightly progressive3 = highly progressive
121 n2_ Lower limit setting range of the maximum speed RPM n2- **) 400 400 A122 n9 Limited speed n9 RPM 9900 **) 400 2000 *) A123 n11 Limited speed n11 RPM 9900 **) 400 2500 *) A124 toP Speed limitation by means of ext. potentiometer RPM 9900 **) Pa.125 4000 A
(maximum value)125 bot Speed limitation by means of ext. potentiometer RPM Pa.124 **) 400 400 A
(minimum value)126 Pot Function “speed limitation by means of external 2 0 0 A
potentiometer”0 = Function “external potentiometer” Off1 = External potentiometer always active2 = External potentiometer active only if one of
inputs in1...i10 has been selected and enabled127 AkS Audible signal of machine run blockage and bobbin 1 0 0 A
thread monitor On/Off128 Asd Start delay, when command “start” is given by ms 2000 **) 0 0 A
covering the light barrier(see parameter 129)
129 ALS Machine start by covering the light barrier 3 0 0 A(only in conjunction with parameter 132 = 1)0 = Function Off1 = Light barrier covered ! pedal forward (>1)
! machine run pedal controlled2 = Pedal forward (>1) ! light barrier covered
! machine run pedal controlled3 = Light barrier covered ! machine run at
automatic speed n12 (without pedal)Caution! If 129 = 3, the machine starts immediatelyafter covering the light barrier without influence bythe pedal! It can be stopped only by uncovering thelight barrier or by machine run blockage! If machinerun blockage is disabled, the machine startsimmediately even if the light barrier is still covered!
130 LSF Light barrier filter for knitted fabrics 1 0 0 *) A131 LSd 0 = Light barrier sensing “covered” 1 0 1 *) A
1 = Light barrier sensing “uncovered”132 LSS 0 = Machine start possible with light barrier 1 0 0 *) A
uncovered or covered.1 = Machine start blocked with light barrier
uncovered if parameter 131 = 1.Machine start blocked with light barriercovered if parameter 131 = 0.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520061
Technician Level
Code no. 190 with control operationCode no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.133 LSE Thread trimming operation, when completing the seam 1 0 1 *) A
after light barrier sensing On/Off134 SSt Softstart On/Off 1 0 0 *) A135 SrS Ornamental backtack On/Off 1 0 0 A136 FAr Trimming stitch backward On/Off 1 0 0 A137 hP High lift for walking foot On/Off 1 0 A139 nIS Display of machine speed On/Off 1 0 0 *) A141 SGn Speed status for the seam with stitch counting 4 0 0 A
0 = Speed controllable by the pedal up to the setmaximum speed (parameter 111)
1 = Fixed speed (parameter 118) without influence bythe pedal (machine stop by pressing the pedalto the basic position)
2 = Limited speed controllable by the pedal up to theset limit (parameter 118)
3 = At fixed speed (parameter 118) can be interruptedby full heelback
4 = At fixed speed (parameter 110) can be interruptedby full heelback.
142 SFn Speed status for the free seam and for the seam with 3 0 0 Alight barrier0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)1 = Fixed speed (parameter 118) without influence by
the pedal (machine stop by pressing the pedalto the basic position)
2 = Limited speed controllable by the pedal up to theset limit (parameter 118)
3 = At fixed speed (parameter 118) can be interruptedby full heelback (only for seams with light barrier).
143 kSA Stitch counting at the start of the seam (e. g. chain 3 0 1 Asuction0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)1 = Fixed speed (parameter 112) without influence by
the pedal (machine stop by pressing the pedalto the basic position)
2 = Limited speed controllable by the pedal up to theset limit (parameter 112)
3 = At fixed speed (parameter 112), can be suspendedor interrupted depending on the setting ofparameter 019.
144 kSE Stitch counting at the seam end (e. g. chain suction) 3 0 1 A0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)1 = Fixed speed (parameter 113) without influence by
the pedal (machine stop by pressing the pedalto the basic position)
2 = Limited speed controllable by the pedal up to theset limit (parameter 113)
3 = At fixed speed (parameter 113), can be suspendedor interrupted depending on the setting ofparameter 019.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A5200 62
Technician Level
Code no. 190 with control operationCode no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.150 t8 Stitch correction of the double start backtack ms 500 0 0 A
(prolongation of the stitch regulator ON period /not effective with ornamental backtack)
151 t9 Stitch correction of the double end backtack ms 500 0 0 A(prolongation of the stitch regulator ON period /not effective with ornamental backtack)
152 thP Run-out time of the high lift walking speed ms 500 80 150 *) A153 brt Braking power at machine standstill 50 0 10 *) A155 LSG Mode signal “run” 4 0 1 A
0 = Signal Off.1 = Signal “run” On.2 = Signal “run” enabled when the speed is >3000 RPM.3 = Signal with pedal <> 0.4 = Signal enabled only after motor synchronization
(one rotation at positioning speed after power On)156 t05 Switch-off delay for the signal “run” or ms 2550 **) 0 0 A
signal with pedal in pos. 0 (neutral)157 SFS Stitches until thread tension release Off after stitches 254 0 0 A
light barrier covered at the start of the seam(effective only in overlock mode)
158 dnL Delay time until light barrier speed release ms 500 0 100 *) A159 cb2 Stitches after light barrier uncovered until stitches 254 0 10 A
signal M9 “hemming blow 2“ Off161 drE Direction of motor rotation 1 0 1 *) A
0 = Clockwise rotation1 = Counterclockwise rotation
170 Sr1 Setting the reference position:- Press the E key.- Press the >> key.- Turn handwheel until symbol on display goes off.
Then set the handwheel to the reference position.- Press the P key twice.
171 Sr2 Setting the needle positions:1E = Start position 1 degrees 359 0 56 A2E = Start position 2 281 A1A = End position 1 98 A2A = End position 2 323 A
172 Sr3 Display on the control:Pos. 1 to 1A (LED 7 lights up)Pos. 2 to 2A (LED 8 lights up)
172 Sr3 Display on the V810 control panel:Pos. 1 to 1A (lefthand arrow above the 4 key On)Pos. 2 to 2A (righthand arrow above the 4 key On)
172 Sr3 Display on the V820 control panel:Pos. 1 to 1A (lefthand arrow above the 7 key On)Pos. 2 to 2A (righthand arrow above the 7 key On)
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520063
Technician Level
Code no. 190 with control operationCode no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.173 Sr4 Checking of the signal outputs and inputs using the
incorporated control panel or the V810/V820 controlpanels01 = Backtacking on socket ST2/3402 = Sewing foot lift on socket ST2/3503 = Output M1 on socket ST2/3704 = Output M3 on socket ST2/2705 = Output M2 on socket ST2/2806 = Output M4 on socket ST2/3607 = Output M5 on socket ST2/3208 = Output M11 on socket ST2/3109 = Output M6 on socket ST2/3010 = Output M9 on socket ST2/2511 = Output M8 on socket ST2/2412 = Output M7 on socket ST2/2313 = Output M10 on socket ST2/29OFF/ON = By actuating the switches connected to the
control, the function of these switches ischecked and displayed on the control.OFF is displayed with open switch and theactivated input in1...i10 with closed switch.
179 Sr5 Control program number with index and identificationnumber. Upon pressing the appropriate key the datawill be displayed in succession.V810 control panel display example:Press the E key ! Display e. g. Sr [°]Press the >> key ! Display e. g. 5200APress the E key ! Display e. g. 981019Press the E key ! Display e. g. 15Press the P key twice! Display Ab320AV820 control panel display example:Press the E key ! Display F-179 Sr5 [°]Press the >> key ! Display e. g. 5200APress the E key ! Display e. g. 98101915Press the P key twice! Display 4000 Ab320ASee instruction manual for control display example.
180 rd Number of reversing increments degrees 359 0 175 *) A181 drd Switch-on delay of reverse motor rotation ms 990 0 10 *) A182 Frd Reverse motor rotation On/Off 1 0 0 *) A183 FFm Disabling of flip-flop functions at the seam end 3 0 0 A
0 = Flip-flop 1 (M6) and flip-flop 2 (M10) not disabledat the seam end
1 = Flip-flop 1 (M6) disabled at the seam end2 = Flip-flop 2 (M10) disabled at the seam end3 = Flip-flop 1 (M6) and flip-flop 2 (M10) disabled
at the seam end184 c6 Number of run-out stitches when unlocking the stitches 254 0 20 *) A
chain185 chP Stitch counting high lift for walking foot stitches 254 0 0 A186 FFi Function “speed limitation n11” 1 0 0 *) A
0 = Speed limitation n11 On, when signal M10 is On.Speed limitation n11 Off, when signal M10 is Off.
1 = Speed limitation n11 Off, when signal M10 is On.Speed limitation n11 On, when signal M10 is Off.
187 FFo Function of signal M10 after “power On” (flip-flop 2) 1 0 0 *) Aon socket ST2/290 = Signal M10 Off / speed limitation n11
according to setting of parameter 1861 = Signal M10 On / speed limitation n11
according to setting of parameter 186
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA AB320A5200 64
Technician Level
Code no. 190 with control operationCode no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.190 MEK Function “unlock the chain” in modes 5, 6, 7 and 16 3 0 1 *) A
(parameter 290)0 = Unlocking the chain Off1 = Unlocking the chain manually (with pedal in
pos. –2 without cutting at the seam end)2 = Unlocking the chain automatically
- by means of light barrier or- pedal in pos. –2 (parameter 019) without
cutting at the seam end3 = Unlocking the chain automatically
- by means of light barrier or- pedal in pos. –2 (parameter 019) with cutting
and run-out stitches (parameter 184) at theseam end, then unlocking the chain (only ifparameter 290 = 7)
191 MHE Seam end in the overlock mode by end count c2 or c4 1 0 0 A0 = Seam end after count c4 – tape cutter1 = Seam end after count c2 – chain suction
192 PLS Speed of the light barrier compensating stitches 1 0 0 *) A0 = Speed n5 after light barrier sensing1 = Speed pedal controlled
193 kSL Enable chain suction signal and thread tension release 1 0 0 A0 = Thread tension release and chain suction after
the light barrier compensating stitches1 = Chain suction from light barrier uncovered
onwards and thread tension release after thelight barrier compensating stitches
194 Stb Function “blow fabric onto stack” 1 0 0 *) A(only if parameter 290 = 16)0 = Blow fabric onto stack at the seam end1 = Blow fabric onto stack from light barrier
uncovered onwards195 LSc Stitches for light barrier monitoring stitches 2550 **) 0 0 A
(light barrier monitoring is off, when set to “0”).196 StL Function “stitch lock” (parameter 290 = 21) 1 0 1 *) A
0 = Stitch lock OffOutput ST2/34 (STV) = Stitch condensing
1 = Stitch lock OnOutput ST2/28 (M2) = Stitch condensingOutput ST2/34 (STV) = Stitch lock
Attention! Upon switching the parameter from 0 to 1 orvice versa, the output function changes accordingly!
198 SAk Functions with chainstitch machines 2 0 0 Ae. g. bag sewing machine (parameter 290 = 5)0 = Function “thread trimming” or “hot thread chain
cutting” and sewing foot lift using the pedal.1 = Function “thread trimming” or “hot thread chain
cutting” by means of knee switch and sewing foot liftusing the pedal.
2 = Function “thread trimming” or “hot thread chaincutting” using the pedal and sewing foot lift by meansof knee switch.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520065
6.4 Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.200 t1 Delay until speed release after start backtack ms 500 0 100 *) A201 t2 Sewing foot lift switch-on delay with half ms 500 20 80 *) A
heelback202 t3 Start delay after disabling the sewing foot ms 500 0 50 *) A
lift signal203 t4 Time of full power of sewing foot lifting ms 600 0 500 *) A204 t5 Holding power for sewing foot lifting % pa. 254 1 40 *) A
1...100%1% ! low holding power100% ! high holding power
205 t6 Thread wiper time ms 2550 **) 0 120 *) A206 t7 Delay from end of thread wiper until sewing ms 800 0 40 *) A
foot lifting On207 br1 Braking effect when modifying the preset value 55 1 10 A
≤ 4 stages208 br2 Braking effect when modifying the preset value 55 1 20 A
≥ 5 stages210 tSr Stop time for switching the stitch regulator ms 500 0 140 A
in the ornamental backtack211 tFL Sewing foot lift switch-on delay with thread ms 500 0 60 *) A
wiper off212 t10 Time of full power of backtacking or thread ms 600 0 200 A
trimmer forward213 t11 Holding power for backtacking or thread % pa. 255 1 12 *) A
trimmer backward 1...100%1% ! low holding power100% ! high holding power
219 br3 Positioning power at stop of the drive 55 1 10 A220 ALF Accelerating power of the drive 55 1 20 A221 dGn Speed gate 1 RPM 990 **) 50 100 A222 tGn Speed gate damping period ms 990 0 120 A
(effective only if parameter 224 = 0)223 dG2 Speed gate 2 RPM 6500 **) 200 1600 A224 dGF Speed gate 2 On/Off 1 0 1 A232 USS Overlock with fast scissors On/Off 1 0 0 A
0 = Tape cutter1 = Fast scissors (set parameter 282 = 0)
234 PdO New start after machine run blockage 1 0 1 A0 = New start after disabling machine run
blockage without influence by the pedal(e. g. with automats)
1 = New start after disabling machine runblockage only if pedal in pos. 0
235 bkS Braking curve in the overlock mode On/Off 1 0 1 A0 = Braking curve Off1 = Braking curve On for precise stop upon chain
suction at the seam end236 FLP 0 = Sewing foot lift possible in all positions 2 0 0 A
1 = Sewing foot lift possible in position 22 = Sewing foot lift at the seam end stored with pedal
backward. Storing undone with pedal slightly forward.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A5200 66
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.239 FEL Selection of the input function on socket B18/5 43 0 0 A
0 = Light barrier function, if 009 = 1All other functions as with parameter 240, exceptparameter 239 = 14. In this case high lift forwalking foot is performed with speed limitationoperational mode not stored.
240 in1 Selection of the input functions on socket ST2/7 43 0 43 *) Afor input 10 = No function1 = Needle up/down2 = Needle up3 = Single stitch (basting stitch)4 = Full stitch5 = Needle to position 26 = Machine run blockage effective with open
contact7 = Machine run blockage effective with closed
contact8 = Machine run blockage unpositioned effective
with open contact9 = Machine run blockage unpositioned effective
with closed contact10 = Automatic speed n12 without pedal
(see parameter 266)11 = Limited speed n12 pedal controlled12 = Sewing foot lifting with pedal in position 0
(neutral)13 = High lift for walking foot with speed limitation n10
(operational mode not stored)14 = High lift for walking foot (flip-flop 1) with speed
limitation n1015 = Tape cutter / fast scissors: function only in
chainstitch and overlock mode16 = Intermediate backtack / intermediate stitch
condensing17 = Stitch regulator suppression / recall18 = Unlocking the chain: can be activated by
keystroke, but will be executed only at theseam end
19 = Reset bobbin thread monitor if parameter030 = >0
20 = Handwheel running in the direction of rotationaccording to the setting of parameter 161
21 = Handwheel running in the opposite direction ofrotation according to the setting of parameter161
22 = Speed limitation n11 (flip-flop 2). OutputST2/29 is enabled according to setting ofparameter 186
23 = No function24 = No function25 = Speed limitation with ext. potentiometer
On/Off (see parameter 126)26 = Manual stacker27 = Unlocking the chain, function is performed
upon pressing the key28 = External light barrier (according to the
setting of parameter 131)
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520067
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.240 in1 29 = “Hemmer foot” signal Off (see parameter 296),
function effective only in the seam30 = High lift for walking foot, if sewing foot is On31 = Function “speed limitation bit0” (speed n11)32 = Function “speed limitation bit1” (speed n10)
(bit0 + bit1 = speed n9).33 = Speed n9 pedal controlled34 = Automatic speed n9 can be suspended by
pressing the pedal to pos. 0 (neutral)35 = Automatic speed n9 can be interrupted by
pressing the pedal to pos. -236 = Automatic speed n9 without pedal37 = Speed n12 pedal controlled (break contact)38 = Automatic speed n12 without pedal
(break contact [N.C.])39 = Switch to the next pattern in TEACH IN40 = Switch back to the previous pattern in TEACH IN41 = Tape cutting only at machine standstill42 = Enable hot thread chain cutting or sewing foot
lifting. Function effective only in the chain stitchmode.
43 = No function241 in2 Selection of input function on socket ST2/11 43 0 43 *) A
for input 20 = No functionAll other functions of the keys as with parameter 240
242 in3 Selection of input function on socket ST2/6 43 0 43 *) Afor input 30 = No functionAll other functions of the keys as with parameter 240
243 in4 Selection of input function on socket ST2/8 43 0 43 *) Afor input 40 = No functionAll other functions of the keys as with parameter 240
244 in5 Selection of input function on socket ST2/5 43 0 43 *) Afor input 50 = No functionAll other functions of the keys as with parameter 240
245 in6 Selection of input function on socket ST2/12 43 0 43 *) Afor input 60 = No functionAll other functions of the keys as with parameter 240
246 in7 Selection of input function on socket ST2/9 43 0 43 *) Afor input 70 = No functionAll other functions of the keys as with parameter 240
247 in8 Selection of input function on socket ST2/10 43 0 43 *) Afor input 80 = No functionAll other functions of the keys as with parameter 240
248 in9 Selection of input function on socket ST2/13 43 0 43 *) Afor input 90 = No functionAll other functions of the keys as with parameter 240
249 i10 Selection of input function on socket ST2/14 43 0 43 *) Afor input 100 = No functionAll other functions of the keys as with parameter 240
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA AB320A5200 68
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.250 iFA Thread trimmer activation angle incr. 500 0 180 *) A
(1 increment = 0.7°)251 FSA Switch-off delay of thread tension release ms 990 0 50 *) A252 FSE Switch-on delay angle of thread tension release incr. 500 0 0 *) A
(1 increment = 0.7°)253 tFA Stop time for thread trimmer ms 500 **) 0 70 *) A254 EF- Upper limit (pa. 204) duty ratio for sewing % 100 1 100 *) A
foot lift 1...100255 EV- Upper limit (pa. 213) duty ratio for backtacking % 100 1 100 *) A
or thread trimmer backward 1...100256 kt6 Delay time of output VR (chain suction), ms 2550 **) 0 250 A
(function only if parameter 290 = 15)257 c7 Start counting until tape cutter M4 On stitches 254 0 5 A
(function only if parameter 290 = 15)258 c8 End counting until tape cutter M4 On stitches 254 0 15 A
(function only if parameter 290 = 15)260 ihr Handwheel increments carried out when the incr. 500 0 10 *) A
key is pressed once (in1...i10)261 nhr Handwheel speed RPM 150 **) 30 50 A262 dhr Delay time until the key is pressed down ms 2550 **) 0 200 *) A
causing the handwheel to rotate continuously(in1...i10).Pressing the key briefly < preset value ofparameter 262: increments set by means ofparameter 260 are carried out.Keeping the key pressed down > preset valueof parameter 262: handwheel rotatescontinuously.
263 ihP 0 = Signal “high lift for walking foot” (M6), when key is 1 0 0 Aclosed.
1 = Signal “high lift for walking foot” (M6), when key isopen.(Function only if parameter 137 = 1)
264 iS1 0 = Signal “manual stacker” (M7), when key is closed. 1 0 0 A1 = Signal “manual stacker” (M7), when key is open.
(Function in all modes except mode 16)265 ktS ON period of manual stacker (M7) ms 2550 **) 0 500 A266 inr 0 = Speed reduction (n12), when key is closed 1 0 0 A
1 = Speed reduction (n12), when key is open269 PSv Positioning shift degrees 100 0 15 *) A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520069
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.270 PGm Connection of a sensor e. g. light barrier sensor to 5 0 0 *) A
light barrier socket B18/7. Selection of the desiredfunction!0 = The positions are generated by means of the
transmitter incorporated in the motor and can be setby means of parameter 171.
1 = Setting the sensor to position 2.Set position 1 using parameter 271, starting fromleading edge position 2.
2 = Setting the sensor to position 2.Set position 1 using parameter 271, starting fromtrailing edge position 2.
3 = Setting the sensor to position 1.Set position 2 using parameter 271, starting fromleading edge position 1.
4 = Setting the sensor to position 1.Set position 2 using parameter 271, starting fromtrailing edge position 1.
5 = No position sensor available. The drive stopsunpositioned. The thread trimmer function issuppressed with this setting.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
= 0V
OUT
OUT
OUT
OUTST2
IN
POS1
ST2/20
POS2
ST2/20
POS1
ST2/21
POS2
ST2/21
POS1
ST2/21
ST2/20
POS2
ST2/20
POS1
POS2
ST2/21
POS
B 18/7
SEN
= high 0256/SEN- 1
Pa 271
Pa 271
Pa 271
Pa 271
360°
270
= 1
270
= 3
270
= 4
270
= 2
+ 5V
0V
EFKA AB320A5200 70
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.270 PGm Connection of a sensor e. g. light barrier sensor to 5 0 0 *) A
light barrier socket B18/7. Selection of the desiredfunction!0 = Function as in table on previous page!1 = Setting the sensor to position 2.
Set position 1 using parameter 271, starting fromtrailing edge position 2.
2 = Setting the sensor to position 2.Set position 1 using parameter 271, starting fromleading edge position 2.
3 = Setting the sensor to position 1.Set position 2 using parameter 271, starting fromtrailing edge position 1.
4 = Setting the sensor to position 1.Set position 2 using parameter 271, starting fromleading edge position 1.
5 = Function as in table on previous page!
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
= 0V
OUT
OUT
OUT
OUT
ST2
IN
POS1
ST2/20
POS2
POS2
ST2/20
POS1
ST2/21
ST2/21
POS1
ST2/20
POS1
ST2/21
POS2
ST2/20
POS
B 18/7
POS2
ST2/21
SEN
= high 0256/SEN- 2
Pa 271
Pa 271
Pa 271
Pa 271
360°
270
= 1
270
= 3
270
= 4
270
= 2
+ 5V
0V
EFKA AB320A520071
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.271 PGr Number of angular degrees after the sensor degrees 255 0 180 *) A
position on the machine handwheel272 trr Transmission ratio between motor shaft and machine 255 020 100 *) A
shaft (calculation formula see instruction manual!)The transmission ratio should be determined andindicated as precisely as possible!
273 Asi Signals M8, M9, M10 On/Off 1 0 0 A(0 = Off, 1 = On)
274 Ad1 Delay time of signal M8 at the start of the seam ms 2550 **) 0 40 *) A275 At1 ON period of signal M8 at the start of the seam ms 2550 **) 0 150 *) A276 Ad2 Delay time of signal M9 at the start of the seam ms 2550 **) 0 50 A277 At2 ON period of signal M9 at the start of the seam ms 2550 **) 0 60 A278 Ad3 Delay time of signal M10 at the start of the seam ms 2550 **) 0 40 A279 At3 ON period of signal M10 at the start of the seam ms 2550 **) 0 350 A280 kd1 Delay time output M1 ms 2550 **) 0 0 *) A281 kt1 ON period output M1 ms 2550 **) 0 100 *) A282 kd2 Delay time output M2 ms 2550 **) 0 100 *) A283 kt2 ON period output M2 ms 2550 **) 0 100 *) A284 kd3 Delay time output M3 ms 2550 **) 0 200 *) A285 kt3 ON period output M3 ms 2550 **) 0 100 *) A286 kd4 Delay time output M4 ms 2550 **) 0 300 *) A287 kt4 ON period output M4 ms 2550 **) 0 100 *) A288 kdF Delay time until sewing foot On ms 2550 **) 0 380 *) A289 kt5 ON period output M7 ms 2550 **) 0 1000 A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A5200 72
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.290 FAM 0 = Lockstitch mode: 24 0 5 A
(FA1, FA2, FA3, FA1+FA2); e. g. BrotherDürkopp Adler, Mitsubishi, Pfaff, Toyota»Slide-in strip for V810 and V820 = 1«
2 = Lockstitch mode: e. g. Singer (212 UTT)»Slide-in strip for V810 and V820 = 1«
3...= Lockstitch mode:e. g. Dürkopp Adler (models 767, N291)»Slide-in strip for V810 and V820 = 1«
4 = Chainstitch mode: e. g. (US80A)»Slide-in strip for V810 = 5«»Slide-in strip for V820 = 3«
5 = Chainstitch mode in general:M1, M2, M3 and M4 parallel sequence»Slide-in strip for V810 = 5«»Slide-in strip for V820 = 3«
6 = Chainstitch mode with tape cutter and/orfast scissors and M1 / M2 at the seam end»Slide-in strip for V810 = 5«»Slide-in strip for V820 = 3«
7 = Overlock mode: e. g. (AC62AV1461)»Slide-in strip for V810 = 7«»Slide-in strip for V820 = 5«
8 = Backlatch mode: Pegasus»Slide-in strip for V810 = 7«»Slide-in strip for V820 = 5«
9 = Backlatch mode: Yamato»Slide-in strip for V810 = 7«»Slide-in strip for V820 = 5«
10 = Lockstitch mode:Union Special (63900AMZ »replacement forUS80A«) and on Refrey lockstitch machines»Slide-in strip for V810 and V820 = 1«
14 = Lockstitch mode: Juki (5550-6, 5550-7)»Slide-in strip for V810 and V820 = 1«
15 = Backlatch mode: Pegasus (SSC100)»Slide-in strip for V810 = 7«»Slide-in strip for V820 = 5«
16 = Overlock mode: feed-off-the-arm machinese. g. Yamato (FD62)»Slide-in strip for V820 = 7«
17 = Chainstitch mode: Pegasus (stitch lock)»Slide-in strip for V810 = 5«»Slide-in strip for V820 = 3«
20 = Lockstitch mode: Juki (LU1510-7)»Slide-in strip for V810 and V820 = 1«
21 = Chainstitch mode with stitch lock:Yamato (VG2730-156M)»Slide-in strip for V810 = 5«»Slide-in strip for V820 = 3«
23 = Lockstitch mode: Dürkopp Adler (271...275)»Slide-in strip for V810 and V820 = 1«
24 = Chainstitch mode: Pegasus (MHG-100)Modes 1, 11...13, 18, 19, 22 are selectable, but theirfunctions correspond to mode 0!
EFKA AB320A520073
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
NoteWhen selecting the trimming mode by means of parameter 290, the connected V810 or V820 control panel is
automatically sensed and the corresponding slide-in strip number is selected by means of parameter 291 and 292,respectively. Should a different strip be inserted, its number can be set by means of parameter 291 and 292, respectively,
after having selected the trimming mode.
Parameter Designation Unit max min Preset Ind.291 810 Select slide-in strip number for the V810 control 8 1 1 *) A
panel (illustrations of slide-in strips see thefollowing chapter 9)
292 820 Select slide-in strip number for the V820 control 10 1 1 *) Apanel (illustrations of slide-in strips see thefollowing chapter 9)
293 tF1 Selection of the input function by means of the 43 0 17 *) A(A) key “F1” on the V810/V820 control panel0 = No function1 = Needle up/down2 = Needle up3 = Single stitch (basting stitch)4 = Full stitch5 = Needle to position 26...12 = No function13 = High lift for walking foot with speed limitation
n10 (operational mode not stored)14 = High lift for walking foot with speed limitation
n10 (operational mode stored)15 = Tape cutter / fast scissors
(in chainstitch and overlock mode)16 = Intermediate backtack/intermediate stitch
condensing17 = Stitch regulator suppression / recall18 = No function19 = Reset bobbin thread monitor if parameter
030 = >020...43 = No function
294 tF2 Selection of the input function by means of the 43 0 1 *) C(B) key “F2” on the V810/V820 control panelFunctions of the key as with parameter 293
295 nAM Switch proximity switches for inputs in2, in7, in8, in9 1 0 0 A296 M08 Functions of signal M8 5 0 0 *) A
0 = Signal M8 Off1 = Signal hemmer foot On at the start of the seam
with pedal in pos. -1 or –2 and in the seam withmachine running
2 = Signal hemmer foot On at the start of the seamwith pedal in pos. -1 or –2 and remains active inthe seam
3 = Signal M8 as center cutter4 = Signal M8 with needle up / down5 = Signal M8 alternating with M3 with “fast scissors”
on overlock machines in mode 16,if parameter 232=1 has been selected
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA AB320A5200 74
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.297 M11 Functions of signal M11 5 0 0 A
0 = Function according to setting of parameter 290.1 = Signal M11 is switched on whenever the light
barrier is covered2 = Signal M11 is switched on whenever the light
barrier is uncovered3 = Signal M11 is switched on only after light barrier
uncovered and/or covered until seam end4 = Signal M11 is switched on as with setting 3.
Signal M5 (machine running), however, isswitched off while signal M11 is issued.When signal M11 is issued, signal M6 (machineat standstill) is also immediately issued.
5 = Signal M11 is switched on from “light barriersensing“, “pedal in pos. –2“ or “‘hemmer footsignal’ key off“ onwards.
298 nSo Backtack synchronization On/Off 1 0 0 A299 nrS Backtack synchronization speed RPM 3000 **) 200 400 A300 AA1 Selectable power transistors for signal A1 12 0 0 A
0 = No function1 = Signal on output M12 = Signal on output M23 = Signal on output M34 = Signal on output M45 = Signal on output M56 = Signal on output M67 = Signal on output M78 = Signal on output M89 = Signal on output M910 = Signal on output M1011 = Signal on output M1112 = Signal on output VR
301 So1 Issue signal A1 3 0 0 A0 = Signal until seam end (according to setting of
parameter 320)1 = Signal over time2 = Signal until seam end and drive stops3 = Signal during stitch counting (according to setting
of parameter 309)302 tr1 Starting point for signal A1 3 0 0 A
0 = Start at the beginning of the seam1 = Start of the signal triggered by light barrier sensing2 = Start of the signal when the drive stops at the seam
end3 = Start from light barrier covered onwards at the
beginning of the seam303 do1 Delay of signal A1 2 0 1 A
0 = No delay until signal On1 = Delay over time until signal On2 = Delay over stitches until signal On
304 dt1 Delay time until signal A1 On ms 2550 **) 0 0 A305 St1 ON period of signal A1 ms 2550 **) 0 0 A306 nA1 Speed mode when signal A1 is On 2 0 0 A
0 = Pedal controlled speed1 = Limited speed n92 = Limited speed n11
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A520075
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.307 A1 Signal A1 On/Off 1 0 0 A308 dA1 Stitches delaying signal A1 stitches 999 0 0 A309 cA1 Stitch counting during signal A1 stitches 999 0 0 A310 AA2 Selectable power transistors for signal A2 12 0 0 A
0 = No function1 = Signal on output M12 = Signal on output M23 = Signal on output M34 = Signal on output M45 = Signal on output M56 = Signal on output M67 = Signal on output M78 = Signal on output M89 = Signal on output M910 = Signal on output M1011 = Signal on output M1112 = Signal on output VR
311 So2 Issue signal A2 3 0 0 A0 = Signal until seam end (according to setting of
parameter 320)1 = Signal over time2 = Signal until seam end and drive stops3 = Signal during stitch counting (according to setting
of parameter 319)312 tr2 Starting point for signal A2 3 0 0 A
0 = Start at the beginning of the seam1 = Start of the signal triggered by light barrier sensing2 = Start of the signal when the drive stops at the seam
end3 = Start from light barrier covered onwards at the
beginning of the seam313 do2 Delay of signal A2 2 0 1 A
0 = No delay until signal On1 = Delay over time until signal On2 = Delay over stitches until signal On
314 dt2 Delay time until signal A2 On ms 2550 **) 0 0 A315 St2 ON period of signal A2 ms 2550 **) 0 0 A316 nA2 Speed mode when signal A2 is On 2 0 0 A
0 = Pedal controlled speed1 = Limited speed n92 = Limited speed n11
317 A2 Signal A2 On/Off 1 0 0 A318 dA2 Stitches delaying signal A2 stitches 999 0 0 A319 cA2 Stitch counting during signal A2 stitches 999 0 0 A320 bP0 Switch-off time of signals A1 and A2 1 0 0 A
0 = Signals effective until seam end1 = Signals effective until pedal is in pos. 0 (neutral)
321 Std Suppression of the seam when 0 stitches are set 1 0 0 A0 = Suppression Off1 = Suppression On
322 dkn 0 = Correction seam Off 2 0 0 A1 = Correction seam On2 = Interruption of seam or pattern by thread trimmer
*) Depending on the selected mode. See table at the beginning of the List of Parameters!**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA AB320A5200 76
Supplier Level
Code no. 311 with control operationCode no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.323 FLn 0 = Sewing foot is not lifted after power On 1 0 0 A
1 = Sewing foot is lifted after power OnThis function is enabled only if TEACH IN is On
324 ti 0 = Teach-in Off 1 0 0 A1 = Teach-in OnTeach-in programming is possible only with V820.Execution of pattern is possible without V820.
500 Sir Recall of Fast Installation Routine (SIR)(see description on page 8!)
NA = Start of seamLS = Light barrier uncovered or covered at the seam endNE = Seam endFA-E = End thread trimming operationP=0 = Pedal in pos. 0 (neutral)St = Stitches
Parameter 320 = 0 ! Signals enabled according to setting of parameter 301/311.Parameter 320 = 1 ! Signals enabled until pedal is in pos. 0 (neutral).
1 12
03
3
3
1
1
1
11
2
2
1
1 02
311
Param eter
301
A2
A1
0 1 2
1
1 1 1
1 0
0
0 11
1 0
303
313312
302
10
10
0100100
0
0
0
0 100
0
0
0 0
100
0
0 100
0
0
10
10
10
0
318
[St]
308
10
0
0
0
0
[m s] [m s]
0 0
100 100
0 100
0100
0 0
314 315
304 305
[St]
0
0
0
0
0
319
309NA
100
100
10 100
10
10 10
10100
100100
100
100
10
NELS
0256/B ILD4
100
FA- E P= 0
EFKA AB320A520077
NA = Start of seamLS-D = Light barrier uncovered ! covered (parameter 131 = 1 and parameter 132 = 0)NE = Seam endFA-E = End thread trimming operationP=0 = Pedal in pos. 0 (neutral)St = Stitches
1) Seam end after stitch counting or light barrier sensing2) Seam end after pedal in pos. -2
30 2
32 1
32 2
1 3 2
3
3
3
2
0
0
1
0
0
133
10
10
10
00
0100 0
0 0
0
0
0
0
0
0
0 0
100
100 0
100 0
0
0
0
0
0
0
0
10
0
0 0 1
0 0 2
031
33
31 1
0
33 2
1 0 2
3
3
0
10
2 0 0
2 0 0
2
311
Param eter
301
A2
A1
3
1
0 0
10
0
0
1
0 0
0 0
0 0
303
313312
302
10
10
10
10
0
0
0
0
100 0
0 0
0 100
100100
0 0
0 0
0
0
0
1000
0 0
100 0
0 0
0 0
0
0
0
10
0
10
0
10
10
0
0
318
[St]
308
0
0
0
0
0
0 0
100100
0 0
0 0
0 100
[m s] [m s]
314 315
304 305
10
0
0
0
0
[St]
319
309NA
100
10
100
10
100
10
100 10
0256/B ILD3
100
10
10
100
100
10
100
100
10
10
10
100
10
10
100100
10
100
LS- D NE
1)
2)
FA- E P= 0
1)
2)
EFKA AB320A5200 78
7 Error Displays
General InformationOn the control On the V810 On the V820 Signification
A1 InF A1 InFo A1 Pedal not in neutral position, when turningthe machine on
A2 -StoP- blinking -StoP- blinking + Machine run blockagesymbol display
A3 InF A3 InFo A3 Reference position is not set
A7 Symbol blinking Symbol blinking Bobbin thread monitor
Programming Functions and Values (Parameters)On the control On the V810 On the V820 Signification
Returns to 000 Returns to 0000 Like V810 + Wrong code number or parameter numberor to last or to last display InFo F1 inputparameter number parameter
number
Serious ConditionOn the control On the V810 On the V820 Signification
E1 InF E1 InFo E1 After power On, position transmitter orcommutation transmitter defective, orconnecting cables have been changed bymistake. During operation or after a sewingcycle, only position transmitter defects canbe identified.
E2 InF E2 InFo E2 Line voltage too low, or time between power offand power on too short.
E3 InF E3 InFo E3 Machine blocked or does not reach the desiredspeed.
E4 InF E4 InFo E4 Control disturbed by deficient grounding orloose contact.
Hardware DisturbanceOn the control On the V810 On the V820 Signification
H1 InF H1 InFo H1 Commutation transmitter cord or frequencyconverter disturbed.
H2 InF H2 InFo H2 Processor disturbed
EFKA AB320A520079
8 Slide-in Strips for the V810/V820 Control PanelsSlide-in strips for the V810 control panel
Slide-in strips for the V820 control panel
NoteWhen changing the setting of parameters 291 / 292, the V810 / V820 functions change as well, save function keys
F1 / F2 which are influenced by parameters 293 /294.
1 2
1 2
1 2
1 2
F
F
F
F
F2
F2
F2
F2
F2
INSERT DELETEF1
INSERT DELETEF1
INSERT DELETEF1
F1
INSERT DELETEF1
9
10KL2256e
7
8
6
R
R
R
R
R
F
F
F
F
F2
F2
F2
F1
F1
F1
3
4
5
1
2
FRANKL & KIRCHNER GMBH & CO KGSCHEFFELSTRASSE 73 – D-68723 SCHWETZINGENTEL.: (06202)2020 – TELEFAX: (06202)202115email: [email protected] – http://www.efka.net
OF AMERICA INC.3715 NORTHCREST ROAD – SUITE 10 – ATLANTA – GEORGIA 30340PHONE: (770)457-7006 – TELEFAX: (770)458-3899 – email: [email protected]
ELECTRONIC MOTORS SINGAPORE PTE. LTD.67, AYER RAJAH CRESCENT 05-03 – SINGAPORE 139950PHONE: 7772459 – TELEFAX: 7771048 – email: [email protected]