Automation and Drives
Automation and Drives
IMATIC NETOverview of theSIMATIC NET Software Products
S
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 3© Siemens AG 2006 - subject to change
Industrial Ethernet
Overview SIMATIC NET PC Products forIndustrial Ethernet
S7-1613
S7-REDCONNECT / Upgrade S7-REDCONNECT
SOFTNET-S7 / SOFTNET-S7 Lean
SOFTNET-PG
PC
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 4© Siemens AG 2006 - subject to change
Industrial Ethernet
PC
S7-1613 Technical Data
Connection of PCs/PGs via CP 1613 / CP 1613 A2 to SIMATIC S5 and S7 with STEP 5/STEP 7 automation systems
IT FTPS5S7PGOPCUDPTCP/IPISOPN
S7 and SEND/RECEIVE OPC server integrated
Only to use withCP 1613/CP 1613 A2
Supports the operation of up to two parallel communication protocols
SMATIC S7-400
CP 443-1 (S7,S/R) ISO + TCP6GK7 443-1EX11-0XE0
CP 443-1 (S7,S/R, HTTP)6GK7 443-1GX11-0XE0
NCM S7manualIndustrial Ethernet(SIMATIC NET CD orInternet Download)
CP 443-1 (S7,S/R) ISO + TCP6GK7 443-1EX11-0XE0
CP 443-1 (S7,S/R, HTTP)6GK7 443-1GX11-0XE0
NCM S7 manualIndustrial Ethernet(SIMATIC NET CD orInternet Download)
SMATIC S7-300
CP 16136GK1 161-3AA00
S7 1613 (communications software)6GK1 716-1C861-3AA0
SMATIC NET Industrial Ethernet(S7 functions)Standard PC with WinCC
e.g. RC64k or RT64k WinCC
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 5© Siemens AG 2006 - subject to change
Industrial Ethernet
S7-1613 Ordering Information
Configuring with STEP 7 and NCM PC6GK1716-1CB61-3AA0
6GK1716-1CB63-3AB0*
Windows 2003 Server + SP1
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
6GK1716-1CB64-3AE0Upgrade Vx.x to V6.4
6GK1716-1CB64-3AA0
* Supplied as copy license (without software CD)
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 6© Siemens AG 2006 - subject to change
Industrial Ethernet
S7-REDCONNECT Technical Information
Software for fail-safe S7 communication(via ISO protocol) of PCs via redundant networks
IT FTPS5S7PGOPCUDPTCP/IPISOPN
S7-1613 software packageintegrated (no additional license needed)
Only to use withCP 1613/CP 1613 A2
Configuring with STEP 7 V5.0 and higher (no NCM PC)
ET 200M
H-CPU insingle mode
S7-400H
PC with 2 x CP 1613 A2and S7-REDCONNECT
Fault-tolerant communication
Industrial Ethernet
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 7© Siemens AG 2006 - subject to change
Industrial Ethernet
S7-REDCONNECT / Upgrade Ordering Information
Configuring with STEP 7 and NCM PC0HB64-3AC0* Power Pack
0HB64-3AE0Upgrade Vx.x to V6.4
0HB63-3AB0**
0HB64-3AA0
Windows 2003 Server + SP1
0HB64-3AE5Upgrade Vx.x to V6.4
0HB63-3AD0*/**
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional / Server + SP3/4
Windows NT4.0 Workstation / Server + SP6a
0HB61-3AA4*
0HB61-3AA0
6GK1716-…
* Upgrade S7-REDCONNECT (Upgrade of exisiting S7-1613 software).** Supplied as copy license (without software CD)
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 8© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-S7 Technical Information
Connection of PCs/PGs via Industrial Ethernet to SIMATIC automation systems
IT FTPS5S7PGOPCUDPTCP/IPISOPN
S7 and SEND/RECEIVEOPC server integrated
Only to use with an interface card, e.g. CP 1612, or integrated Industrial Ethernet interface
S5-115U to -155Uwith CP 1430 TF
IndustrialEthernet
PC/PG with SOFTNETfor Industrial Ethernet
S7-300with
CP 443-1
S7-200with CP 243-1
S7-400with CP 343-1
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 9© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-S7 / SOFTNET-S7 Lean Ordering Information
Configuring with NCM PC and STEP 71CW61-3AA0
1CW64-3AE0Upgrade Vx.xto V6.4
1LW63-3AB0*/**
1CW64-3AA0
1LW64-3AA0*
Windows 2003 Server + SP1
1LW64-3AE0*Upgrade Vx.xto V6.4
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional / Server + SP3/4
1CW63-3AB0**6GK1704-…
* SOFTNET-S7 Lean, max. eight S7 and PG/OP interconnections (max. 64 with SOFTNET-S7)
** Supplied as copy license (without software CD)
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 10© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-PG Technical Information
PG/OP connection of PCs/PGs via Industrial Ethernet to SIMATIC automation systems
IT FTPS5S7PGOPCUDPTCP/IPISOPN
Only to use with an interface card, e.g. CP 1612, or integrated Industrial Ethernet interface
Integrated in STEP 7 V5.3 and higher
S5-115U to -155Uwith CP 1430 TF
IndustrialEthernet
PC/PG with SOFTNETfor Industrial Ethernet
S7-300with
CP 443-1
S7-200with CP 243-1
S7-400with CP 343-1
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 11© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-PG Ordering Information
Windows 2003 Server + SP1
1PW61-3AA0
1PW63-3AB0*
1PW64-3AA0
Windows XP Professional + SP1/2
Windows 2003 Server + R2
(SP3)Windows 2000 Professional / Server + SP3/4
Windows NT4.0 Workstation / Server + SP6a
Windows 98 / Windows ME
1PW64-3AE0Upgrade Vx.x to V6.4
1PW33-3AA06GK1704-...
* Supplied as copy license (without software CD)
Industrial Ethernet
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 12© Siemens AG 2006 - subject to change
Industrial Ethernet
Overview SIMATIC NET PC Products forPROFIBUS
S7-5613
DP-5613
FMS-5613
SOFTNET-S7
SOFTNET-DP
SOFTNET-DP slave
CP 5613/14 software
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 13© Siemens AG 2006 - subject to change
Industrial Ethernet
S7-5613 Technical Information
connection of PCs/PGs via PROFIBUS to SIMATIC S5 and S7 with STEP 5/STEP 7 automation systems
PCSMATIC S7-400
CP 443-1 (S7,S/R) ISO + TCP6GK7 443-1EX11-0XE0
CP 443-1 (S7,S/R, HTTP)6GK7 443-1GX11-0XE0
NCM S7 manualIndustrial Ethernet(SIMATIC NET CD orInternet Download)
CP 443-1 (S7,S/R) ISO + TCP6GK7 443-1EX11-0XE0
CP 443-1 (S7,S/R, HTTP)6GK7 443-1GX11-0XE0
NCM S7 manualIndustrial Ethernet(SIMATIC NET CD orInternet Download)
SMATIC S7-300
CP 16136GK1 161-3AA00
S7 1613 (communications software)6GK1 716-1C861-3AA0
SMATIC NET Industrial Ethernet(S7 functions)Standard-PC with WinCC
e.g. RC64k or RT64k WinCC
FMS OPCS5S7PGDP
S7 and SEND/RECEIVE OPC server integrated
Only to use with CP 5613, CP 5613 A2, CP 5613 FO, CP 5614, CP 5614 A2, CP 5614 FO
Supports the operation of up to two parallel communication protocols
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 14© Siemens AG 2006 - subject to change
Industrial Ethernet
S7-5613 Ordering Information
Configuring with NCM PC
Windows 2003 Server + SP1
5CB63-3AB0*
5CB64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5DB64-3AE0Upgrade Vx.xto V6.4
5CB61-3AA06GK1713-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 15© Siemens AG 2006 - subject to change
Industrial Ethernet
e.g. ET200
Slave
DP-5613 Technical Information
PCs/PGs with PROFIBUS interface can operate as DP master class 1 and class 2 within one PROFIBUS segment
PC
FMS OPCS5S7PGDP
DP and SEND/RECEIVE OPC server integrated
Only to use with CP 5613, CP 5613 A2, CP 5613 FO, CP 5614, CP 5614 A2, CP 5614 FO
Supports the operation of up to two parallel communication protocols
e.g. SPS/PC e.g. PC
Control tasks and diagnostics
Engineeringand diagnostics
Master diagnosticsRead bus parametersDownload/Upload etc.
Configuration
Parameterization
Read data input
Write data output
Read diagnostics data
Read input data
Read output data
Slave diagnostics
Read configuration
Address modification
Alarm acknowledge
Read/write data record
(acyclic)
Read/write records(acyclic)
Equidistance
Intermode communication
DP Master Class 1 DP Master Class 2
DP-
V0
DP-
V1
DP-
V2
DP-
V0
DP-
V1
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 16© Siemens AG 2006 - subject to change
Industrial Ethernet
DP-5613 Ordering Information
Configuration with NCM PC and STEP 7
Windows 2003 Server + SP1
5DB63-3AB0*
5DB64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5DB64-3AE0Upgrade Vx.x to V6.4
5DB61-3AA0
6GK1713-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 17© Siemens AG 2006 - subject to change
Industrial Ethernet
FMS-5613 Technical Information
PCs/PGs can exchange data via the FMS (Field Message Specification) interface with FMS-capable PLCs (e.g. S5/S7) and devices of other manufacturers
PC
FMS OPCS5S7PGDP
Only to use with CP 5613, CP 5613 A2, CP 5613 FO, CP 5614, CP 5614 A2, CP 5614 FO
FMS OPC serverintegriated
Supports the operation of up to two parallel communication protocols
PROFIBUS FMS
PG with STEP 7and STEP 5 field device
S7-300with CP 343-5
S7-400with CP 443-5 Basic PC WinCC with
CP 5613 A2 andFMS-5613
S5-115U-155U withCP 5431 FMS/DP
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 18© Siemens AG 2006 - subject to change
Industrial Ethernet
FMS-5613 Ordering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
5FB63-3AB0*
5FB64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5FB64-3AE0Upgrade Vx.x to V6.4
5FB61-3AA0
6FK1713-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 19© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-S7 Technical Information
The PROFIBUS S7 programming interface of the PG/PC enables the easy and flexible access of SIMATIC S7 datavia SOFTNET-S7
S7 and SEND/RECEIVE OPC server integrated
Only to use with CP 5511, CP 5512, CP 5611 A2 and integriated PROFIBUS interface of SIMATIC PGs/PCs
S5-115U to S5-155Uwith CP 5431 FMS/DP
PROFIBUS
PC/PG with CP 5611 A2/CP 5512 and SOFTNET for PROFIBUS
S7-400with CP 443-5
FMS OPCS5S7PGDP
S7-300 to CP 342-5 with CP 343-5
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 20© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-S7 Ordering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
5CW63-3AB0*
5CW64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5CW64-3AE0Upgrade Vx.x to V6.4
5CW61-3AA0
6GK1704-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 21© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-DP Technical Information
PCs/PGs can operate as DP master class 1 or 2 or as DP slave via the PROFIBUS interface with SOFTNET DP
DP and SEND/RECEIVE OPC server integrated
Only to use with CP 5511, CP 5512, CP 5611 A2 and integrated PROFIBUS interface of SIMATIC PGs/PCs
S5-115U to S5-155Uwith CP 5431 FMS/DP
PROFIBUS
PC/PG with CP 5611 A2/CP 5512 and SOFTNET for PROFIBUS
S7-400with CP 443-5
FMS OPCS5S7PGDP
S7-300 with CP 342-5 or CP 343-5
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 22© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-DP Ordering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
5DW63-3AB0*
5DW64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5DW64-3AE0Upgrade Vx.x to V6.4
5DW61-3AA0
6GK1704-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 23© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-DP SlaveTechnical Information
PCs/PGs can operate as DP master class 1 or 2 or as DP slave via the PROFIBUS interface with SOFTNET DP
DP slave OPC serverintegrated
Only to use with CP 5511, CP 5512, CP 5611 A2 and integrated PROFIBUS interface of SIMATIC PGs/PCs
S5-115U to S5-155Uwith CP 5431 FMS/DP
PROFIBUS
PC/PG with CP 5611 A2/CP 5512 and SOFTNET for PROFIBUS
S7-400with CP 443-5
FMS OPCS5S7PGDP
S7-300 with CP 342-5 or CP 343-5
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 24© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-DP SlaveOrdering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
5SW63-3AB0*
5SW64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
5SW64-3AE0Upgrade Vx.x to V6.4
5SW61-3AA0
6GK1704-…
* Supplied as copy license (without software CD)
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 25© Siemens AG 2006 - subject to change
Industrial Ethernet
CP 5613/14 Software Technical Information
Connecting the PROFIBUS interface to the PROFIBUS segment *
DP and SEND/RECEIVE OPC server integrated
The following CPs aresupplied with the software: CP 5613, CP 5613 FO, CP 5613A2, CP 5614, CP 5614 FO, CP 5614 A2
DP and S/R communicationcan be operated in parallel
FMS OPCS5S7PGDP
* Software is supplied with the ordering of a CP
SIMATIC S7-400controlle(DP master)
Non-SiemenssystemsProgramming
device
e.g. Robotcontrol
PC
ET 200S ET 200S
ET 200MET 200pro
PROFIBUS DP
DP masterDP slave
CP 5614 A2+
PROFIBUS DP
PROFIBUS
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 26© Siemens AG 2006 - subject to change
Industrial Ethernet
Overview SIMATIC NET PC Products forSNMP & DX
SNMP OPC server Basic
SNMP OPC server Extended
SNMP OPC server Power Pack
DX (Data Exchange) OPC serverSNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 27© Siemens AG 2006 - subject to change
Industrial Ethernet
Configuring with STEP 7/NCM PC
MIB compiler for connecting of non-Siemens systems
Auto discovery (ab STEP7 V5.3+SP3)
Read/write data of any SNMP device(SNMP V1)
Controlling of non SNMP-capableIP devices (ICMP-Ping)
Tested with WinCC (V5.x and higher) and PCS7 (V6.0+SP3 and higher)
SNMP OPCDXTCP/IPPN CBAPN IO
SNMP OPC server enables diagnostics and parameterization of any SNMP device (e.g. SCALANCE X). The OPC server exchanges data via the SNMP protocol. All information can be integrated in OPC-compatible systems e.g. into theHMI system WinCC. A combined process and network diagnostics in the HMI systems can be realised.
Microsoft OfficeOPC client
WinCCOPC client
SIMATIC NETOPC scout
InternetIntranet
SNMPOPC server
SNMP
PN CBA OPC serverPN IO OPC server
PROFINET
S5-OPC server
SNMP
S7-OPC server
SNMP
DP-OPC serverFMS-OPC server
SNMP
OPC XML DAas Web service
DX OPC-Server
OPC XMLWeb client
PC/Windows PC
S7-300
FMS-PCS7-400
SIMATIC S5(only SEND/RECEIVE)
S7-PCET 200pro
PRO
FIB
US
SIMATIC S5
COM/DCOM
SNMP OPC Server Technical Information
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 28© Siemens AG 2006 - subject to change
Industrial Ethernet
SNMP OPC Server Basis Ordering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
1NW63-3AB0*
1NW64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
1NW64-3AE0Upgrade Vx.x to V6.4
1NW61-3AA0
6GK1706-…
Basic = Administration of up to 20 IP addresses
* Supplied as copy license (without software CD)
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 29© Siemens AG 2006 - subject to change
Industrial Ethernet
SNMP OPC Server ExtendedOrdering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
1NX63-3AB0*
1NX64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
1NX64-3AE0Upgrade Vx.x to V6.4
1NX61-3AA0
6GK1706-…
Extended = Administration of up to 200 IP addresses* Supplied as copy license (without software CD)
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 30© Siemens AG 2006 - subject to change
Industrial Ethernet
SNMP OPC Server Power Pack Ordering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
1NW63-3AB0* 1NW64-3AA0
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
Windows NT4.0 Workstation /Server + SP6a
1NW61-3AA06GK1706-…
Power Pack = Upgrade from Basic to Extended version* Supplied as copy license (without software CD)
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 31© Siemens AG 2006 - subject to change
Industrial Ethernet
Communication protocols can beexecuted in parallel
SNMP OPCDXTCP/IPPN CBAPN IO
OPC DX enables communication between OPC-DA and OPC-DX servers in Ethernet networks (OPC DX functionality 1.0 for horizontal communicationbetween OPC servers). In contrast, only client server communication can beexecuted with OPC-DA. Additionally, DX OPC servers can exchange data between OPC servers of other manufacturers.
DX OPC-ServerTechnical Information
OPC DXcommunication
DAOPCserver
DAOPCserver
DXOPCserver
DAOPCserver
OPC DAcommunicationIndustrial
Ethernet
Client
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 32© Siemens AG 2006 - subject to change
Industrial Ethernet
DX OPC Server Ordering Information
Additionally to a standard OPC server, a DX OPC serversupplies intermode communication between OPC servers
Windows 2003 Server + SP1
0XW64-3AA0 0XW64-3AE0Upgrade Vx.x to V6.4
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
0XW63-3AB0*6GK1706-…
* Supplied as copy license (without software CD)
SNMP & DataExchange
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 33© Siemens AG 2006 - subject to change
Industrial Ethernet
Overview SIMATIC NET PC Products forPROFINET
PROFINET CBA OPC server
SOFTNET PROFINET IO
PROFINET
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 34© Siemens AG 2006 - subject to change
Industrial Ethernet
Support of in STEP 7 / SIMATIC iMap defined variables
Communicationprotocols can beexecuted in parallel, e.g. S7 communicationvia SOFTNET S7
SNMP OPCDXTCP/IPPN CBAPN IO
The PROFINET CBA OPC server enables diagnostics and configuration via Industrial Ethernet with PROFINET CBA components
PROFINET CBA OPC Server Technical Information
ET 200S
PROFINETcomponent
ET 200X
PROFINETcomponent
ET 200S
PROFINETcomponent
ET 200L
PROFINETcomponent
Panel-PCwith WinACPROFINET
PROFINETcomponent
PROFIBUS DP
e.g. S7-300 with CP 343-1 PN
PROFINETcomponent
e.g. S4-300 withCP 443-1 Advanced
IE/PB Link PN CBAas proxy
PROFIBUS DP
Industrial Ethernet
PROFINET ProTool/ProOPC client
PN CBA OPC server
PC
S7-OPC server
SOFTNET-S7
PROFINET
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 35© Siemens AG 2006 - subject to change
Industrial Ethernet
PROFINET CBA OPC serverOrdering Information
Configuring with NCM PC and STEP 7
Windows 2003 Server + SP1
0HB64-3AA0 0HB64-3AE0Upgrade Vx.x to V6.4
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
0HB63-3AB0*6GK1706-…
* Supplied as copy license (without software CD)
PROFINET
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 36© Siemens AG 2006 - subject to change
Industrial Ethernet
IO controller functionalityintegrated
Can be operated withintegrated Ethernet interface
Configuring with STEP 7/ NCM PC V5.3 SP1 and higher
SNMP OPCDXTCP/IPPN CBAPN IO
PGs/PCs can be connected to Industrial Ethernet withPROFINET via SOFTNET PN IO –Communication to field devices
InternetIntranet
OPC XML DAas web service
ET 200pro
Microsoft OfficeOPC client
WinCCOPC client
SIMATIC NETOPC scout
OPC XMLWeb client
COM/DCOM
SOFTNET-PROFINET IO Technical Information
PN IO OPC server
PROFINETcommunication SOFTNET PN IO
IE/PB LinkPN IO
e.g. S7-300 withCPU 31x andCP 343-1 AdvancedET 200S with
IM 151-3 PN
ET 200S
e.g. S7-300 withCP 342-5 as slave
PC/PG mitSOFTNET PN IO
PROFIBUS DP
Industrial EthernetPROFINET
PROFINET
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
PROFIBUS
SNMP & DataExchange
PROFINET
Bernhard, Teufel; A&D SC IC; 09/2006, page 37© Siemens AG 2006 - subject to change
Industrial Ethernet
SOFTNET-PROFINET IO Ordering Information
Configuring with NCM PC and STEP7
Windows 2003 Server + SP1
1HW64-3AA0 1HW64-3AE0Upgrade Vx.x to V6.4
Windows 2003 Server + R2
Windows XP Professional + SP1/2
Windows 2000 Professional /Server + SP3/4
1HW63-3AB0*6GK1704-…
* Supplied as copy license (without software CD)
PROFINET
SIMATIC NET Networking for Industry
Automation and Drives
SIMATIC NET
Any questions? Please contact us:
PreSales Support Tel.: +49 911 895-2905
E-Mail:[email protected]
Top Related