Find a contact near you by visiting www.suezwatertechnologies.com and clicking on “Contact Us.” *Trademark of SUEZ; may be registered in one or more countries. ©2017 SUEZ. All rights reserved. FSmbrZMODL_EN.docx Jan-14
Water Technologies & Solutions fact sheet
Z-MOD L Packaged Plants MBR Platform Systems featuring LEAPmbr* technology
LEAPmbr benefits • LEAPmbr air scour utilizes large bubbles for
increased membrane scouring effectiveness while consuming 30% less energy
• Smallest footprint MBR available on the market today
benefits • ZeeWeed* 500 is a reinforced, robust ultrafiltration
membrane that operates in the toughest conditions (high solids, wastewater environment) while producing superior effluent quality
• Modular design allows for high level of flexibility in process and sizes
• In-situ membrane cleaning and backpulse ensure robust performance with minimal downtime under adverse conditions
• Short delivery timeline from submittal to a fully operating system
• Prefabricated, skid mounted equipment minimizes site work and reduces on-site installation costs
• Ideal for expansions, where accommodations for higher future flows are needed
• Complete technical documentation provided with every system
LEAPmbr Air Scour Aeration
traditional air scour
Page 2 FSmbrZMODL_EN.docx
Z-MOD L MBR Platform Systems: 10-1120 USgpm train capacity
options available • Side loading or top loading stainless steel mem-
brane tank. Top loading tank comes with rails and grating. Side loading tank requires ZW500D short 300ft2 membranes.
• Chemical feed systems • Permeate turbidity • 480V, 60Hz or 600V, 60Hz • Air compressors & driers • Motor starter panel • Pump to / pump from Return Activated Sludge
(RAS) designs and equipment • Biological equipment options & UV system • Pretreatment options (enhanced coagulation & pH
adjustments) for phosphorus removal
lifecycle services with lifetime support • Most extensive service team in the industry • Remote monitoring to help optimize plant’s perfor-
mance • Off-site technical support professionals available
24/7 • Upgrades to help you advance with SUEZ’s technol-
ogy
instrumentation Flow Permeate Pressure Permeate Level Membrane tank, CIP/BP tank
materials of construction Air piping Stainless steel, Sch. 10 Low-pressure piping Sch. 80, PVC Pump Skid Frame Painted carbon steel Membrane Tank Concrete or stainless steel
membrane modules Membrane Model ZeeWeed 500 Style Immersed UF hollow fiber Membrane type Reinforced PVDF
typical effluent quality BOD < 5 mg/L TSS < 3 mg/L TKN/Ammonia < 1 mg/L TP/Phosphorous 1 < 1 mg/L Turbidity < 1 NTU 1 With coagulation addition
permeate pump skid • Reversible rotary lobe pump
for permeation and back-pulse
• Remote I/O panel • Flow meter • VFD & disconnect
membrane scouring blower assembly • Primary blower
• Backup blower option
FSmbrZMODL_EN.docx Page 3
system parameters
Operating Temperature Range 32 to 104ºF (0 to 40°C)
Operating Transmembrane Pres-sure Range -8 to 8 psig (-55 to55 kPa)
# of Trains Available 1 to 4
electrical & maintenance information
Programmable Logic Computer
PLC Program
Human Machine Interface
HMI Program
Master PLC Panel
Input / Output Modules
Remote I/O Panel
Communication Network
Allen Bradley Compact Logix
RS Logix 5000 version 16.0
Allen Bradley Panelview 1250
RS Factoryview version 4.0
NEMA 12 (separate unit)
Allen Bradley Flex I/O
NEMA 4 (skid mounted)
Ethernet
Power 480/600 VAC, 3-phase, 60Hz
Control Circuit 120VAC, 1-phase, 60Hz
train models Z-MOD L70 Z-MOD L160 Z-MOD L280 Z-MOD L630 Z-MOD L1120
permeate pump skid
(1 per train)
Min. Flow Rate (gpm) 10 46 68 155 210
Max. Flow Rate (gpm)1 70 160 280 630 1120
Motor (VAC, phase, Hz) 3 HP
480/600, 3, 60
7.5 HP
480/600, 3, 60
10 HP
480/600, 3, 60
15 HP
480/600, 3, 60
30 HP
480/600, 3, 60
Total Discharge Head (ft.) 45 45 45 45 45
permeate skid dimensions
Skid Height (in.) 68 69 69 69 69
Skid Width (in.) 44 52 56 60 65
Skid Length (in.) 64 69 69 78 86 1 Applies to pump only, membrane would not be able not maintain this flow for extended periods of time
Page 4 FSmbrZMODL_EN.docx
train models Z-MOD L70 Z-MOD L160 Z-MOD L280 Z-MOD L630 Z-MOD L1120
blower
(shipped loose)
Operating conditions 36 to 72 ICFM @ 4.7 to 5.3 PSI
Motor (VAC, phase, Hz) 5hp
480/600, 3, 60
7.5hp
480/600, 3, 60
10hp
480/600, 3, 60
20hp
480/600, 3, 60
25hp
480/600, 3, 60
Membrane Cassette Information
Membrane Type Reinforced, Submerged Hollow Fibre Ultrafiltration Membrane
Membrane Name ZW500d
Membrane surface area (ft2)
(per module) 370
Max Module #/Train
(limited by Backpulse Flow) 14 32 55 124 192
Typical # of 16 Module Cassettes/Train 1 1,2 N/A N/A N/A
Typical # of 48 Module Cassettes/Train N/A 1 1 2 3,4
concrete membrane tank
(constructed by customer)
Tank Height (in.) 144
Height (in.)
(req. for membrane lifting) 330
Tank Width (in.) 108
Tank Length (in.)
(dependent on # of cassettes/train) 60 60, 96 102 180 260, 340
installation and utility requirements
Pump to
Pump from
Pump to
Pump From
Pump to
Pump from
Pump to
Pump From
Pump to
Pump From
Permeate Header (in.) 2 4 4 6 8
Drain (in.) 4 4 4 6 10
Permeate Pump Skid Discharge (in.) 2 4 4 6 8
Membrane Aeration Connection (in.) 2 3 3 4 6
operation and maintenance consumption (approximate, per train)
Power Consumption (kw/year) 154,000 373,000 614,000 1,078,000 1,800,000
Citric Acid Consumption (L/yr) 200 225 750 1450 2100-2900