X-Smart IQ™ Getting Started Guide - Dentsply Maillefer · 2017-05-30 · use, please fully charge...
Transcript of X-Smart IQ™ Getting Started Guide - Dentsply Maillefer · 2017-05-30 · use, please fully charge...
Getting Started Guide Just a few images to help you set up your motor easily and get the most out of it.
X-Smart IQ™
X-Smart IQ™ Getting Started Guide
2 iPad® set-up
!
The following steps must be performed before installing the iPad mini™ in the protective case.
A Activate the AssistiveTouch feature The AssistiveTouch feature allows to emulate the iPad mini™ Home button which is not accessible when in the protective case.
Accessibility AssistiveTouch
B Activate the Bluetooth® The connection between the motor handpiece and the application is done via Bluetooth®.
Bluetooth®
C Activate the Wi-Fi Wi-Fi is necessary to download the application from the App Store®.
Select the Wi-Fi network and enter your password to connect the iPad mini™.
Wi-Fi
D Set the volume to maximum
E Download the application from the App Store®
If you do not already have an Apple ID, follow the procedure on the “http://www.apple.com/support/appleid/” website.
Dentsply Endo IQ
Files*
AC adapter
Handpiece protective sleeves samples (5x)
iPad Mini™ protective case*
Rubber plugsand foams*
Spray nozzle(used for lubrication)
Contra-angle
Motor handpiece
Motor handpiece support and case
Getting Started Guide
* Depending on the kit
Accessories for iPad Mini™ 1, 2 or 3
Accessories for iPad Mini™ 4
1 Package contents
X-Smart IQ™ Getting Started Guide
3 Hardware installation
!
Only for first use, please fully charge the motor handpiece (~ 6 hours) to optimize battery life.
G
A According to your iPad Mini™ model, use the suitable kit.
B Stick the foams of your kit at the places indicated on the protective case.
Accessories for iPad MiniTM 1, 2 or 3 Accessories for iPad MiniTM 4
!
C Enclose and center the iPad MiniTM in the protective case. Place the corresponding rubber plugs on the camera and the charging port.
D Separate the motor handpiece cover from the motor handpiece support.
For iPad Mini™ 1, 2 or 3
For iPad Mini™ 4
!
!
Accessories foriPad Mini™ 1, 2 or 3
Accessories foriPad Mini™ 4
E Install the motor handpiece case as protective case holder*.
4 Connect the App
F Only for the first use, select your stand-alone mode. See section 6 Motor handpiece operation for more information.
A Now that your motor handpiece is fully charged: Open the application.
D Check the motor handpiece serial number and click on the corresponding number on the iPad® screen.
C Wait a few seconds until the application detects the motor handpiece.
B Awaken the motor handpiece by pressing on the multifunction button once. Press the button again to activate the Bluetooth® and confirm that the Bluetooth® blue LED is blinking.
* The iPad® protective case and the motor handpiece cover produce static magnetic fields.
FE When the motor handpiece is connected, the icon
changes and the Bluetooth® blue LED switches from blinking to solid.
X-Smart IQ™ Getting Started Guide
5 Using the App
Access to user data and logout
Consult and edit treatment reports
Bluetooth® connection between the iPad mini™ and the motor handpiece (signal power)
Motor handpiece level battery
Access to the stand-alone mode selection (see next page)Dynamic directions-for-use
Access to Parameters (volume, language, etc.), Statistics and Information
Consult the file library and create or edit file sequences
A Home Screen
B C
B Start Treatment
Select your file sequence (or file system)
Visualize the torque that was applied to the file
Enable or disable the auto-reverse function
Motor handpiece calibration
Adjust torque andspeed parameters
C Start and Record Treatment
Create or select a patient record number
Visualize the torque that was applied to the file
Stop recording the treatment and send a PDF report by e-mail
Enter treatment data (notes, working lengths, last file used, obturation method)
Select your file sequence (or file system)
X-Smart IQ™ Getting Started Guide
6 Motor Handpiece operation
Stand-alone Mode
The stand-alone mode allows you to work without the iPad® if needed. After the first connection, if you turn on the motor handpiece without connecting it to the iPad®, it will run with the stand-alone mode settings.
How to set the stand-alone mode
Help to identify a problem and verify the status of the motor handpiece.
A From the application click on this icon.
B Select between Continuous or Reciprocating stand-alone modes.
Disconnect the motor handpiece.
Motor START/STOP button.
Battery charge LED status.
Multifunction button
The multifunction button provides the following functions:
Connects the motor handpiece to the application via Bluetooth®.
Awakens the motor handpiece (the motor handpiece does not turn off, it automatically switches to stand-by mode).
Advance to the next file during a treatment.
Double press to move to the previous file.
Continuous rotation mode LED status.
Reciprocating motion mode LED status.
iPad® / motor handpiece Bluetooth®
connection LED status.
7 After use
Remove the iPad mini™ from the protective case
Full recharge: 6 hours Autonomy: 16 treatments
Store and charge the motor handpiece
A
B
Red On: Low battery.Red Blinking: Critical low battery.
Green On: Charged.Green blinking: Device charging.
C
3 7
X-Smart IQ™ Getting Started Guide
9 Tips & Tricks
10 Additional information
! This document does not replace the User Manual. Please read carefully the User Manual that is available from any page of the application through this icon and on www.dentsplymaillefer.com.
! Check regularly for updates on the App Store®.
! Always check the application compatibility on i before updating iOS on your iPad®.
If you wish to have a printed version of your User Manual, we will be happy to send you a copy (free of charge within 7 calendar days to any address in the EU). To order, simply and conveniently send your request to [email protected].
You can also find more information (tutorial videos, tips & tricks, FAQ) on www.dentsplymaillefer.com.
For support question, please contact your sales representative.
Press the multifunction button to switch to the next file. Double press to move to the previous file. To reset the motor handpiece, press the multifunction button for 10s.
Multifunction button
8 Disinfection and cleaning
Please follow the User Manual for complete disinfection, sterilization and cleaning procedures.
Do not use chloride detergent materials.
Do not use bleach or chloride disinfectant materials.
! Use only a disinfecting solution which is approved for its efficacy (VAH/DGHM-listing, CE marking, FDA and Health Canada approval) and in accordance with the User Manual of the disinfecting solution manufacturer.
Foreword
General recommendations
!
Only use the motor handpiece with a single-use protective sleeve (reference A105800000000 X-SMART iQ Handpiece Sleeves).
Pinch 5 fingers together to close an application and return to the home screen or use the virtual home button. See section 2 iPad® setup for more information.
Close an application
Motor handpiece
3
iPad® Protective Case
3
INL
/ B
EN
XS
IQ T
IP 0
00
/ 0
0/2
017
– c
reate
d 0
1/20
17
Maillefer Instruments Holding SàrlChemin du Verger 3 - 1338 Ballaigues - SwitzerlandPhone: +41 (0)21 843 92 92 [email protected] www.dentsplymaillefer.com0086