www.intertek.com1
UN 38.3 Shock Test Data Collection
Rich Byczek, Intertek
Oct 2013
1http://www.psessymposium.org/
![Page 2: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/2.jpg)
www.intertek.com2
T4: Shock
• Small Cells/Batteries = 150g/6ms = consumer battery specs
• Large Cells/ Batteries= 50g/11ms = automotive OEM Specs
• Large Cells -> Small Batteries: Cells at 50G, Battery at 150G
![Page 3: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/3.jpg)
www.intertek.com3
Measurement Methods
Shipping of Representative shipments and packaging.
• OEM selected Samples
• OEM selected Methods
• Small, Medium, Large sample shipments
![Page 4: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/4.jpg)
www.intertek.com4
Measurement Methods
INTERTEK RECOMMENDATIONS
Pallet (LTL) and Small (UPS, FEDEX, etc)
Assume small parcels have the roughest handling.
Measure at package, not at device (do not assume dampening)
![Page 5: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/5.jpg)
www.intertek.com5
Measurement Methods
Measurement Equipment
EDR-3C by IST
- 3axis internal accelerometer
- Use 2 to test both package and
battery.
- Set minimum G threshold, to collect primarily shock pulse data (i.e. 3G, 5G)
![Page 6: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/6.jpg)
www.intertek.com6
Measurement Methods
May require multiple runs per shipment size and type.
• Set realistic thresholds to maximize data collection
• Potential variation from shipment to shipment
• Variation based on sample and packages size and method.
![Page 7: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/7.jpg)
www.intertek.com7
Measurement Methods
Measurement Analysis
- Convert recorded data to time history
- Cursory review of peaks and durations
- Data “reduction” based on revised threshold
- Statistical calculation of Peak G and Duration
![Page 8: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/8.jpg)
www.intertek.com8
Measurement Methods
Resultant Shock Pulse ASSUMPTIONS
• Half Sine Pulse
• Small/ Large have separate parameters
• Peak G level: based on max for each shipment size, regardless of method
• Duration: based on average pulse width above threshold
• Pulse Count: TBD, based on average pulses per shipment
![Page 9: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/9.jpg)
www.intertek.com9
Measurement Methods
NOTE on PEAK and NUMBER of PULSES:
Increasing number of pulses may be a way to reduce test peak levels.
Typical 1-3 pulse per direction is an ACCELERATED TEST, and therefore peak G level may not be representative of actual accumulated stress.
Alternate is realistic G level, with representative test duration (number of pulses seen in a typical or multiple shipments)
![Page 10: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/10.jpg)
www.intertek.com10
Vibration and Shock
• “Test cells and batteries shall be secured to the testing machine by means of a rigid mount”
• Fixturing:
• Support the product
• May simulate packaging
• May simulate mounting in position
• Not well defined currently.
• Cannot assume package dampening
![Page 11: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/11.jpg)
www.intertek.com11
Vibration and Shock
• CONSIDER WHAT IS BEING SHIPPED!
• CONSIDER HOW IT IS SHIPPED!
• CONSIDER HOW IT IS TRANSPORTED AFTER INITIAL SHIPMENT
![Page 12: Www.intertek.com1 UN 38.3 Shock Test Data Collection Rich Byczek, Intertek Oct 2013 1](https://reader036.fdocuments.in/reader036/viewer/2022062307/5518c43f550346a61f8b56ff/html5/thumbnails/12.jpg)
www.intertek.com12
THANKYOU
Mike WellsVibration Test Department Manager
Rich ByczekIntertek Global Technical Lead
Electric Vehicle & Energy Storage248-219-1099