WPS500/S EP Series
www.powerlinkworld.com
Model Length (L) mm
Width (W)mm
Height (H) mm
Dry Weightkg
WPS500 3771 1165 2143 3809WPS500S 4500 1550 2450 5264
Features: • Rotate speed governor: Electronic • Excitation system: self-excited, SHUNT • A.V.R model: R250/R450 • Emergency stop switch • ATS (automatic transfer switch) receptacle •2x12V sealed for life maintenance free battery • Lockable battery isolator switch • Powder coated canopy (Only for Soundproofed sets) • 50℃radiator • Oil pump on the engine • Steel base frame with fork holes • Vibration isolators between the engine/alternator and base frame
• Dry type air filter • Base fuel tank for daily running • Drain points for fuel tank • Operation Manual / Specifications
Notes: ***
Ratings at 0.8 power factor
Engine Make & Model: Perkins 2506A-E15TAG2
Alternator Brand: Leroy somer
Alternator Model: LSA47.2M7
Control System: Auto Gen
Circuit Breaker Type: 3 Pole MCCB
Frequency & Phase: 50Hz & 3PH
Engine Speed: RPM 1500 Fuel Tank Capacity: litres WPS500 WPS500S
950 1020
Fuel Consumption: l/hr (100% Load)
- Prime Power -Standby Power
95 104
Generating Set Model Prime Power* Standby Power**
WPS500 500kVA/400kW 550kVA/440kWWPS500S 500kVA/400kW 550kVA/440kW
Dimensions and Weights
Output Ratings
Ratings and Performance Data
*Prime Power Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without over load; Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m(328ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
2/ 5
WPS500/S EP Series
www.powerlinkworld.com
Engine Speed: rpm 1500
Gross Engine Power: kWb
- Prime - Standby
451
495
BMEP: kPa
- Prime - Standby
2405
2640
Cooling System Capacity: l 58.0 Capacity without Radiator: N/A Energy to coolant and Oil:
kWt - Prime - Standby
147 165
Energy to Radiation:
kWt - Prime 31.2 - Standby 35
Radiator Fan Load: kW N/A Radiator Cooling Airflow: m³/min 722 External Restriction to Cooling Airflow: Pa N/A
No. of Cylinders / Alignment: 6/Vertical, in-line Cycle: 4 Stroke Bore / Stroke: mm 137/171 Induction: Turbocharged Cooling Method: Water cooled Governing Type: Electronic Governing Class: ISO 8528‐5 class G3
Compression Ratio: 16:1 Displacement: 15.2L Moment of Inertia: kg m² 2.3291 Engine Electrical System:
- Voltage / Ground - Battery Charger Amps
24/Negative
24/70
Weight: kg - Dry - Wet
1633 1714
Oil Filter Type: Spin-On, Full Flow Total Oil Capacity: l 62.0 Minimum: l 45.0 Oil Type: API-CI4/ACEA-E5
Oil Cooling Method: Water-cooled
Silencer Type: Industrial Exhaust outlet size: 127mm Silencer Noise Reduction Level: N/A Maximum Allowable Back Pressure: kPa
6.8
Exhaust Gas Flow: m³/min - Prime - Standby
94 98
Exhaust Gas Temperature: °C - Prime - Standby
N/A 550
Designed to operate in ambient conditions up to 50°C (122°F). Contact your local PowerLink Dealer for power ratings at specific site conditions
Fuel Filter Type: Replaceable Element
Recommended Fuel: Diesel Class A2
Fuel Consumption: l/hr
Prime 110% Load
100% Load
75% Load
50% Load
WPS500 104 95 72 50
WPS500S 104 95 72 50
(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2)
The weights are approximate and without fuel.
Air Filter Type: Paper Element
Combustion Air Flow: m³/min
- Prime - Standby
35.8 36.6
Max. Air Intake Restriction: kPa -clean filter -dirty filter
3.7 6.2
Engine Technical Data
Exhaust System
Fuel System
Air Systems
Engine model:2506A-E15TAG2
Performance
Lubrication System
Cooling System
3/ 5
WPS500/S EP Series
www.powerlinkworld.com
Manufactured by: Leroy somer Model: LSA47.2M7 No. of Bearings: Single
Insulation Class: H
Winding Pitch Code: 2/3
Wires: 12
Ingress Protection Rating: IP23
Excitation System: SHUNT, AREP or PMG
AVR Model: R250, R450
Overspeed: rpm 2250min‐1
Voltage Regulation: (Steady state) ±0.5%
Wave Form NEMA = TIF: <50
Wave Form IEC = THF: <2%
Total Harmonic content LL/LN: No load <1.5%‐on load
<2%
Radio Interference:
Radiant Heat: kW (Btu/min) -WPS500
-WPS500S
Data Item
Motor Starting Capability* kVA
1073/1195 1073/1195
Short Circuit Ratio** %
0.41 0.41
Reactances: Per Unit Xd
X'd X"d
307
307
15.9 15.9
11.1 11.1
Voltage Prime: Standby: kVA kW kVA kW
380/220V 500 400 550 440
400/230V/200V 500 400 550 440
415/240V 500 400 550 440
Voltage Prime: Standby: kVA kW kVA kW
380/220V 500 400 550 440
400/230V/200V 500 400 550 440
415/240V 500 400 550 440
Alternator model: LSA47.2M7
Alternator Operating Data
Alternator WPS500 WPS500S Performance Data:
Alternator Physical Data
Voltage Technical Data WPS500S Voltage Technical Data WPS500
4/ 5
WPS500/S EP Series
www.powerlinkworld.com
Control System
PLC-7420
FEATURES
Microprocessor control, with high stability and credibility . Mains supply and generator operation monitoring.
Indicating operation status and fault conditions. Multiple protections; multiple parameters display, such as pressure, temperature. Manual and automatic work mode selectable. Real time clock for time and date display, overall runtime display, 99 log entries . Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed. Communication with PC via RS485 or RS232 interface, using MODBUS protocol. Engine ECU is available. Common USB cable is usable for parameter configuration. Multi-language is available.
PLC-920 (Optional)
FEATURES
Parameter configuration via RS-232 serial communication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers.
5/ 5
WPS500/S EP Series
www.powerlinkworld.com
Optional
If you have any question or inquiry, please contact PowerLink sales organization or contact: [email protected] Specification may change without prior notice. For more info, please contact PowerLink or your local distributors. EP Series/2013 1st Edition
Engine Alternator Generator Set Fuel System Canopy
Water Jacket Preheater
Oil Preheater
Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and
anti-corrosion treatment
Anti-condensation heater
Tools with the machine
Low fuel level alarm
Automatic fuel feeding system
Fuel T-valves
Weatherproof canopy
Lubricating System Exhaust System Cooling System Control System Voltages
Oil with the machine
Protection board from hotness
Front heat protection
Coolant (-30°C)
Remote control panel
PLC-920 ATS
415/240V 400/230V 380/220V 220/127V 200-115V
No. Part Name Part No. Qty Remark
1 Fuel Filter CH10931 6
2 Pre‐fuel filter CH10930 6
3 Oil Filter CH10929 6
4 Air Filter SEV551F/4 5
5 ALTERNATOR BELT CH11202 1
6 FAN BELT CH11950 1
7 SEAL ‐ ROCKER BOX COVER CH11353 1
8 GASKET ‐ CYLINDER HEAD KRP1529 1
9 THERMOSTAT CH11620 2
10 FRONT OIL SEAL CH11379 1
11 SEAL ‐ REAR END OIL CH11304 1
The following lists are optional by the needs of customers.
Minor Repair / 1000 hrs optional
Local Distributor