GIRNT INDUSTRIES. INC.

July 15, 2005

Mr. Wayne Price New Mexico Oil Conservation Division 1220 South St. Frances Dr. Santa Fe, New Mexico 87505

Ms. Hope Monzeglio NMED Hazardous Waste Bureau 2905 Rodeo Park Dr. East. BLDG 1 Santa Fe, New Mexico 87505

Re: Giant Refining Company's - Bloomfield's River Terrace Voluntary Corrective Measures Work Plan

Mr. Price & Ms. Monzeglio:

As requested in our June 29, 2005 telephone call, Giant is submitting the enclosed information related to the proposed amendments to the May 25, 2005 VCM Work Plan (Work Plan), and additional information that supplements the Work Plan. The information is summarized below.

Bioventing Well Layout As we discussed, Giant plans to use vertical bioventing wells on an approximate 40-foot grid in lieu of the trenches presented in the Work Plan. Figure 1 shows the approximate locations of the bioventing wells. Figure 2 shows the approximate area of influence of the bioventing wells. The bioventing pilot test at the Bloomfield Crude Station concluded a 30-foot radius of influence could be achieved at that site. We have conservatively assumed a 20-foot radius of influence will be achieved at the river terrace.

River Terrace Groundwater Conditions Figure 3 presents an estimated isocontour map of benzene concentrations in the river terrace groundwater. The contours are based on an average composite of the groundwater sampling data collected between October 2004 and April 2005. This figure was developed to determine the area of focus for the bioventing system as shown in Figure 2.

Bioventing Piping Concept Figure 4, which supersedes Figure 9 of the Work Plan, shows the conceptual layout ofthe bioventing and dewatering piping, and the general location of the treatment equipment area. Figure 5 and Figure 6 show the conceptual piping connections to the bioventing and dewatering wells.

Well Design Figure 7 shows a schematic ofthe bioventing wells. Each well will be outfitted with two casings, one to ventilate the upper portion of the interval of interest during the initial stages of dewatering, and the other to ventilate the lower portion as dewatering progress occurs.

Page 3: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Giant Bloomfield River Terrace Page 2 of 2 VCM Work Plan Amendments July 15,2005

The change between casings will be made manually using a flexible venting hose from the main air header.

Figure 8 shows a schematic of the dewatering wells (DW-1 and DW-2).

Temporary Piezometers TP-9 Through TP-13 Appendix A contains the well logs for TP-9 through TP-13, which were installed in April 2005. Appendix B contains the laboratory reports for groundwater samples obtained from TP-9 through TP-13 shortly after their installation.

VCM Major Equipment The following table lists the preliminary equipment selection. Manufacturers' equipment data sheets are contained in Appendix C.

Description Equipment Design Condition Groundwater pump, MW-48 and DW-2

Grundfos 5S03-9(l/3 hp) 5 to 7 gpm

Groundwater pump, DW-1 Grundfos 16S05-5 (1/2 hp) 15 to 20 gpm Liquid-phase GAC treatment US Filter/Westates ASC 2000 40 gpm Bioventing blower Rotron DR 808, 7.5 hp 10 to 20 scfm per well

at 10 inches water column wellhead pressure.

VCM Implementation Schedule Figure 9 shows the revised estimated VCM implementation schedule.

Please feel free to call me if you have any questions.

Sincerely,

James R. Schmaltz Environmental Manager Giant Refining Company - Bloomfield

Page 4: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 5: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 6: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 7: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 8: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 9: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 10: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

V V \ ^ V \ V V V V \ V V ^ V V V \ ^

Clean Backfill

Bentonite

2 ft bgs

3 ft bgs

Filter Pack (10x20 Silica Sand)

5 ft bgs

8 ft bgs

10 ft bgs

*not to scale

2-foot stick up

Ground Surface r u M v r \ w \ l \ \ \ \ \ \ \ \

4-inch Diameter Borehole

1-inch Diameter Schedule 40 PVC

1-inch Diameter Schedule 40 PVC Slotted Screen 0.020 Slot

(each 5-feet long)

End Cap

MALTOyVt PIRNIE

Schematic Bio-Venting Well Design Giant Refinery Bloomsfield, New Mexico

Malcolm Pirnie, Inc.

Figure 7

Page 11: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Clean Backfill

Bentonite

2 ft bgs

5 ft bgs

Filter Pack (8x12 Silica Sand)

Nacimiento Formation

14 ft bgs

.15ft_bg.s_

4-inch Diameter Water Tight Well Seal

2-foot stick up Ground Surface

T T T T T T T T T T T T T T T T T T Y V V T

8-inch Diameter Borehole

4-inch Diameter Schedule 40 PVC

1-inch Diameter Schedule 40 PVC Sounding Tube

Submersible Pump on Schedule 80 PVC Drop Pipe (pump setting 14-feet bgs)

4-inch Diameter Schedule 40 PVC Slotted Screened 0.040 Slot

(10-feet long)

1-inch Diameter Schedule 40 PVC Slotted Screen 0.020 Slot and end cap

(5-feet long)

Sump and End Cap (approximately 1-foot into Nacimiento)

*not to scale

MAlJCOLjM PIRNIE

Schematic Dewatering Well Design Giant Refinery Bloomsfield, New Mexico

Malcolm Pirnie, Inc.

Figure 8

Page 12: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 13: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

APPENDIX A

Soil Boring Logs for TP-9 through TP-13

Page 14: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Sheet: 1 OF 5 Bore Point: River Terrace

Water Elevation: 7.0' Boring No.: TP-9

Precision Engineering, Inc. P.O. Box 422

Las Cruces, NM 88004 505-523-7674

Log of Test Borings

File #: 05-038 Site: Bloomfield Giant Refining

Elevation: EXISTING Date: 4/5/2005

LAB # DEPTH BLOW

COUNT PLOT SCALE MATERIAL CHARACTERISTICS

(MOISTURE, CONDITION, COLOR.ETC.) %M LL PI CLASS. 0.0-7.5 ///**///

///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**/// ///**///

Clav, Slightly Sandy, Very Fine, Brown, Moist, Gravel, Cobbles

2.5

5.0

7.0 ///**/// Water ///**/// 7.5

7.5-10.0 ********* ********* *******!

*********

Sand, Very Fine, Grey, Water Bearing

10.0 10.0 TD

Set 2" Well@ 10.0' 5' of Screen, 6' of Riser Top of Sand 3.1' Top of Bentonite 1.5'

15.0

20.0

SIZE & TYPE OF BORING: 4 1/4" ID HOLLOW STEMMED AUGER LOGGED BY: KMM \\Phoenix\Projects\5127003\River Terrace VCM\River Terrace Work Plan\Wor

Page 15: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Sheet: 2 OF 5 Bore Point: River Terrace

Water Elevation: 4'2" Boring No.: TP-10

Precision Engineering, Inc. P.O. Box 422

Las Cruces, NM 88004 505-523-7674

Log of Test Borings

File #: 05-038 Site: Bloomfield Giant Refining

Elevation: EXISTING Date: 4/5/2005

LAB # DEPTH BLOW

COUNT PLOT SCALE MATERIAL CHARACTERISTICS

(MOISTURE, CONDITION, COLOR.ETC.) %M LL PI CLASS. 0.0-2.0 Silt, Sandy, Very Fine, Brown, Gravel, Cobbles

Moist

2.0-8.5 2.5

Sand, Very Fine to Fine, Silty, Brown, Gravel, Cobbles, Damp

* * * * + *

*** *** *** ***

*** ***

** ***

*** ***

*** *•*

Water 5.0

7.5

8.5

10.0

TD

Set 2" Well @ 8.5' 5' of Screen, 5' of Riser Top of Sand 2.5' Top of Bentonite 1.5'

15.0

20.0

SIZE & TYPE OF BORING: 4 1/4" ID HOLLOW STEMMED AUGER LOGGED BY: KMM \\Phoenix\Projects\5127003\River Terrace VCMVRiver Terrace Work Plan\Wor

Page 16: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Sheet: 3 OF 5 Bore Point: River Terrace

Water Elevation: 5.3' Boring No.: TP-11

Precision Engineering, Inc. P.O. Box 422

Las Cruces, NM 88004 505-523-7674

Log of Test Borings

File #: 05-038 Site: Bloomfield Giant Refining

Elevation: EXISTING Date: 4/5/2005

LAB # DEPTH BLOW

COUNT PLOT SCALE MATERIAL CHARACTERISTICS

(MOISTURE, CONDITION, COLOR.ETC. %M LL PI CLASS. 0.0-2.0 /////////

///////// /////////

Clav, Brown, Moist, Gravel, Cobbles

2.0-3.5

3.5-5.0

5.0-9.5

* * *jj***

* * *^* * * ***j i*** *** *** *** *** *** *** *** *** ********

Sand, Clayey, Brown, Moist, Gravel, Cobbles 2.5

Sand, Silty, Brown, Damp, Gravel, Cobbles

5.0 Sand, Fine to Coarse,.Tan, Damp, Wet

5.3' Water

******** ******** ******** ******** ********

7.5

9.5 10.0

TD

Set 2" Well @ 9.5' 5' of Screen, 5' of Riser Top of Sand 3.5' Top of Bentonite 1.4'

15.0

20.0

SIZE & TYPE OF BORING: 4 1/4" ID HOLLOW STEMMED AUGER LOGGED BY: KMM \\Phoenix\Projects\5127003\River Terrace VCM\River Terrace Work PlanVWor

Page 17: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Sheet: 4 OF 5

Bore Point: RiverTerrace

Water Elevation: 7.5'

Boring No.: TP-12

Precision Engineering, Inc.

P.O. Box 422

Las Cruces, NM 88004

505-523-7674

Log of Test Borings

File #: 05-038

Site: Bloomfield

Giant Refining

Elevation: EXISTING

Date: 4/5/2005

LAB # DEPTH BLOW

COUNT PLOT SCALE MATERIAL CHARACTERISTICS

(MOISTURE, CONDITION, COLOR.ETC. %M LL PI CLASS. 0.0-3.0 *** ***

*** ***

*** ***

Sand, Very Fine to Fine, Slightly Silty, Brown, Gravel, Cobbles, Moist

2.5 3.0-4.5 ////**///

////**/// ////**///

Clav, Sandy, Very Fine, Brown, Some Gravel/ Cobbles, Moist

4.5-9.0 ***yy*** *** jj***

***jj***

*** jj***

*** II*** *** I I***

7/*' ***//***

5.0 Sand, Very Fine to Fine, Clayey, Brown, Moist, Some Gravel

7.5

9.0-13.0

******** ******** ******** ******** ******** ******** ******** ******** ******** ******** ********

Water

Sand. Fine to Coarse, Tan, Water Bearing

10.0

13.0

15.0

TD

Set 2" Well@ 12.0' 5' of Screen, 8' of Riser Top of Sand 5'2" Top of Bentonite 4'2"

20.0

SIZE & TYPE OF BORING: 4 1/4" ID HOLLOW STEMMED AUGER LOGGED BY: KMM \\Phoenix\Projects\5127003\River Terrace VCM\River Terrace Work PlanWVor

Page 18: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Sheet: 5 OF 5 Bore Point: River Terrace

Water Elevation: 6.0' Boring No.: TP-13

Precision Engineering, Inc. P.O. Box 422

Las Cruces, NM 88004 505-523-7674

Log of Test Borings

File #: 05-038 Site: Bloomfield Giant Refining

Elevation: EXISTING Date: 4/5/2005

LAB # DEPTH BLOW

COUNT PLOT SCALE MATERIAL CHARACTERISTICS

(MOISTURE, CONDITION, COLOR.ETC.) %M LL PI CLASS. 0.0-1.5 Silt, Sandy, Very Fine to Fine, Brown, Moist,

Gravel, Cobbles 1.5-8.5 ***//*"

*** jj-kick

***jj***

*** j j***

*** jl***

*** j I***

*** 11*** ***11*** *** a*** *** a***

Sand, Very Fine, Clayey, Brown, Moist, Gravel, Cobbles

2.5

5.0

6.0 *** a*** *** a*** *** a***

7/'

Water Level 6.0'

7.5 ***//***

8.5-14.0 ///////// ///////// ///////// ///////// ///////// ///////// ///////// ///////// ///////// ///////// ///////// /////////

Clay, Grey/Black, Moist, No Hydrocarbon Odor

10.0

14.0 15.0

TD

Set 2'" Well @ 14.5' 10' of Screen, 5' of Riser Top of Sand 2.5' Top of Bentonite 1.5'

20.0

SIZE & TYPE OF BORING: 4 1/4" ID HOLLOW STEMMED AUGER LOGGED BY: KMM \\Phoenix\Projects\5127003\River Terrace VCM\River Terrace Work Plan\Wor

Page 19: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

APPENDIX B

Laboratory Reports for April 2005 Groundwater Samples from TP-9 through TP-13

Page 20: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

H A L L E N V I R O N M E N T A L A N A L Y S I S L A B O R A T O R Y

COVER LETTER

April 19, 2005

Cindy Hurtado San Juan Refining #50 CR 4990 Bloomfield, NM 87413 TEL: (505) 632-4161 FAX (505) 632-3911

RE: River Terrace Investigation TP9-TP13 Order No.: 0504087

Dear Cindy Hurtado:

Hall Environmental Analysis Laboratory received 5 samples on 4/8/2005 for the analyses presented in the following report.

These were analyzed according to EPA procedures or equivalent.

Reporting limits are determined by EPA methodology. No determination of compounds below these (denoted by the ND or < sign) has been made.

Please don't hesitate to contact HEAL for any additional infonnation or clarifications.

Sincerely,

Andy Freeman, Business Manager Nancy McDuffie, Laboratoiy Manager

4901 Hawkins NEs Suite Da Albuquerque, NM B7109 505.345.3975 H Fax 505.345.4107

www.hallenviranrnental.com

Page 21: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratoi y Dale: l9-Apr-05

CLIENT:

Lab Order:

Project:

Lab ID:

San Juan Refining 0504087

River Terrace Investigation TP9-TPI3

0504087-01

Client Sample ID: TP-9

Collection Date: 4/7/2005 2:00:00 PM

Matrix: AQUEOUS

Analyses Result P Q L Qual Units DF Dale Analyzed

EPA METHOD B015B: DIESEL RANGE Analyst: S C C Diesel Range Organics (DRO) ND 1.0 mg/L 1 4/13/2005 8:22:05 AM Molor Oil Range Organics (MRO) ND 5.0 mg/L 1 4/13/2005 8:22:05 AM

Surr: DNOP 113 58-140 %REC 1 4/13/2005 8:22:05 AM

EPA METHOD 8015B: GASOLINE RANGE Analyst: NSB Gasoline Range Organics (GRO) 0.67 0.050 rng/L 1 4/8/2005 11:26:46 PM

Surr BFB 103 78.3-120 %REC 1 4/8/2005 11:26:46 PM

EPA METHOD 8021B: VOLATILES Analyst: NSB Methyl lert-butyl ether (MTBE) ND 2.5 M9/L 1 4/8/2005 11:26:46 PM Benzene 3.3 0.50 ug/L 1 4/8/2005 11:26:46 PM Toluene 5.0 0.50 ug/L 1 4/8/2005 11:26:46 PM Ethylbenzene 7.0 0.50 ug/L 1 4/8/2005 11:26:46 PM Xylenes, Total 22 0.50 ug/L 1 4/8/2005 11:26:46 PM

Surr 4-Bromofluorobenzene 116 83.3-121 %REC 1 4/8/2005 11:26:46 PM

Qualifiers: ND - Not Delecled al the Rcponing Limit

J - Anaiyte delecled below quanlilalion limits

B - Analyle delecled in the associated Meiliod Blank

* - Value exceeds Maximum Contaminanl Level

1/12

S - Spike Recovery outside accepled recovery limits

R - RPD outside accepted recovery limils

E - Value above quantitation range

Page 1 of 5

Page 22: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratory Dale: 19-Apr-05

CLIENT:

Lab Order:

Project:

Lab ID:

San Juan Refining 0504087

River Terrace Investigation TP9-TP13

0504087-02

Client Sample ID: TP-10

Collection Date: 4/7/2005 2:20:00 PM

Matrix: AQUEOUS

Analyses Result PQL Qual Units D F Date Analyzed

EPA METHOD 8015B: DIESEL RANGE Analyst: SCC Diesel Range Organics (DRO) ND 1.0 mg/L 1 4/13/2005 9:22:37 AM Molor Oil Range Organics (MRO) ND 5.0 mg/L 1 4/13/2005 9:22:37 AM

Sure DNOP 90.4 58-140 %REC 1 4/13/2005 9:22:37 AM

EPA METHOD 8015B: GASOLINE RANGE Analyst: NSB Gasoline Range Organics (GRO) ND 0.050 mg/L 1 4/8/2005 11:56:47 PM

Surr BFB 101 78.3-120 %REC 1 4/8/2005 11:56:47 PM

EPA METHOD 8021B: VOLATILES Analyst: NSB Melhyl tert-butyl ether (MTBE) ND 2.5 pg/L 1 4/11/2005 1:01:27 PM

Benzene ND 0.50 ug/L 1 4/11/2005 1:01:27 PM Toluene NO 0.50 ug/L 1 4/11/2005 1:01:27 PM

Ethylbenzene ND 0.50 ug/L 1 4/11/2005 1:01:27 PM Xylenes, Total 0.56 0.50 ug/L 1 4/11/2005 1:01:27 PM

Surr: 4-BrQmQfluorobenzene 98.6 B3.3-121 %REC 1 4/11/2005 1:01:27 PM

Qunlifiers: ND - Nol Delected at the Reponing Limit S - Spike Recovery outside accepled recovery limils

J - Anaiyte delected below quanlilalion limils R - RPD outside accepted recovery limils

B - Aiiolylc delected in die associated Method Blank E - Value above quantitation range

* - Value exceeds Maximum Contaminant Level 2 / 1 2 P Q g e 2 o f 5

Page 23: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratory Date: I9-Apr-05

CLIENT:

Lab Order:

Project:

Lab ID:

San Juan Refining

0504087

River Terrace Investigation TP9-TP13

0504087-03

Client Sample ID: TP-11

Collection Dale: 4/7/2005 1:00:00 PM

Matrix: AQUEOUS

Analyses Result P Q L Qual Units DF Date Analyzed

EPA METHOD 8015B: D IESEL RANGE Analyst: SCC Diesel Range Organics (DRO) ND 1.0 mg/L 1 4/13/2005 9:52:33 AM Motor Oil Range Organics (MRO) ND 5.0 mg/L 1 4/13/2005 9:52:33 AM

Sum DNOP 124 58-140 %REC 1 4/13/2005 9:52:33 AM

EPA METHOD 8015B: GASOLINE RANGE Analyst: NSB Gasoline Range Organics (GRO) 0.082 0.050 mg/L 1 4/9/2005 12:26:49 AM

Surr. BFB 101 78.3-120 %REC 1 4/9/2005 12:26:49 AM

EPA METHOD 8021B: VOLATILES Analyst: NSB Methyl tert-butyl ether (MTBE) ND 2.5 ug/L 1 4/9/2005 12:26:49 AM Benzene 1.5 0.50 ug/L 1 4/9/2005 12:26:49 AM Toluene 1.6 0.50 Ug/L 1 4/9/2005 12:26:49 AM Ethylbenzene ND 0.50 ug/L 1 4/9/2005 12:26:49 AM Xylenes, Total 2.7 0.50 ug/L 1 4/9/2005 12:26:49 AM

Sum 4-Bromonuorobenzene 103 83.3-121 %REC 1 4/9/2005 12:26:49 AM

Qualifiers: ND - Not Detected at the Reporting Limit S - Spike Recovery outside accepted recovery limits

J - Anaiyte detected below quantitation limits R - RPD outside accepted recovery limils

B - Analyle delecled in the associated Method Blank E - Value above quantitation range

* - Value exceeds Maximum Conlaminam Level 2> I \ 1 P a S e 3 of 5

Page 24: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratory Date: l'J-Apr-05

CLIENT: San Juan Refining Lab Order: 05040S7

Project: River Terrace investigation TP9-TPI3

Lab ID: 0504087-04

Client Sample ID: TP-12

Collection Date: 4/7/2005 1:20:00 PM

Matrix: AQUEOUS

Analyses Result PQL Qual Units DF Date Analyzed

E P A METHOD 8015B: DIESEL RANGE Analyst: SCC Diesel Range Organics (DRO) ND 1.0 mg/L 1 4/13/2005 10:22:31 AM Motor Oil Range Organics (MRO) ND 5.0 mg/L 1 4/13/2005 10:22:31 AM

Surr: DNOP 112 58-140 %REC 1 4/13/2005 10:22:31 AM

E P A METHOD 8015B: GASOLINE RANGE Analyst: NSB Gasoline Range Organics (GRO) ND 0.050 mg/L 1 4/9/2005 12:56:46 AM

Surr: BFB 99.2 78.3-120 %REC 1 4/9/2005 12:56:46 AM

E P A METHOD 8021B: VOLATILES Analyst: NSB Melhyl tert-butyl ether (MTBE) ND 2.5 ug/L 1 4/9/2005 12:56:46 AM Benzene 0.75 0.50 pg/L 1 4/9/2005 12:56:46 AM Toluene 0.80 0.50 ug/L 4/9/2005 12:56:46 AM Ethylbenzene ND 0.50 MQ/L 1 4/9/2005 12:56:46 AM Xylenes. Total 1.0 0.50 ug/L 1 4/9/2005 12:56:46 AM

Sum 4-Bromo(luorobenzene 103 83.3-121 %REC 1 4/9/2005 12:56:46 AM

ND - Not Delected nt the Reponing Limit

J - Anatyte delecled below quantitation limits

B - Anaiyte delected in the associated Method Blank

* - Value exceeds Maximum Contaminant Level

S - Spike Recovery oulside accepted recoveiy limils

R - RPD outside accepted recovery limits

E - Value above quantitation range

Page 4 of 5

Page 25: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratory Date: I9-Apr-05

CLIENT:

Lab Order:

Project:

Lab ID:

San Juan Refining 0504087

River Terrace Investigation TP9-TP13

0504087-05

Client Sample ID: TP-13

Collection Date: 4/7/2005 2:45:00 PM

Matrix: AQUEOUS

Analyses Result PQL Qual Units DF Date Analyzed

EPA METHOD B015B: DIESEL RANGE Analyst: SCC Diesel Range Organics (DRO) ND 1.0 mg/L 1 4/13/2005 10:52:24 AM Motor Oil Range Organics (MRO) ND 5.0 mg/L 1 4/13/2005 10:52:24 AM

Surr. DNOP 128 5B-140 %REC 1 4/13/2005 10:52:24 AM

EPA METHOD 8015B: GASOLINE RANGE Analyst: NSB Gasoline Range Organics (GRO) ND 0.050 mg/L 1 4/9/2005 1:26:44 AM

Sum BFB 102 78.3-120 %REC 1 4/9/2005 1:26:44 AM

EPA METHOD 8021B: VOLATILES Analyst: NSB Melhyl tert-butyl elher (MTBE) ND 2.5 1 4/9/2005 1:26:44 AM

Benzene 2.3 0.50 ug/L 1 4/9/2005 1:26:44 AM Toluene 2.2 0.50 pg/L 1 4/9/2005 1:26:44 AM

Ethylbenzene 0.55 0.50 ug/L 1 4/9/2005 1:26:44 AM Xylenes, Tolal 3.6 0.50 pg/L 1 4/9/2005 1:26:44 AM

Sum 4-Bromofluorobenzene 101 B3.3-121 %REC 1 4/9/2005 1:26:44 AM

ND - Not Detected at the Reporting Limit

J - Anaiyte detected below quantitation limits

B - Anaiyte delected in Ihe associated Method Blank

* - Value exceeds Maximum Contaminant Level

S - Spike Recovery outside accepted recovery limits

R - RPD oulside accepted recovery limits

E - Value above quanlilalion range

Page 5 of 5

Page 26: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

" 1

Ki t-H

o ca •J

13 c < I d

> W

13

c

DQ

o

on

I Pi

ft

c o ta oa

QJ

d O > cd m • «

C/l O P i

O

z

_1 "Bi E

< CN

< f -

S S 1— cc

3 o

Q

CC

Q a. ce

CD cc a CL

cc

5 o

O LU CC

ID

cc a. cn

a. in

a 0 -

ra —

>. Z ra ST < co

5 9

cc

cc

E G> ro = w o

3

a

a • . cc

D LL CC

5 cc a CL

cc

111

cc

sc o. w

CL CO

CU CC

a cn

Ct) O) c ro tn CC u. oj cn

| I fc I ui CO i ra

i a

o z

3 <

o i n

s P ca l i .

co a.

cc

c QJ CT)

O

a LL cc

a 0 ,

cc

5 cc Q

cc

X

u LU CC

ro >

CC

0_

a CL

01

cc

a 2

OJ

C

CC u. co tt l

ra w

" E x i — 3 !?

o

'E

D Z

6/12

Page 27: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

f—

o

C/D

u

c C3

PQ -a o

oo .c c « 0J

S 0 0

rs o cd i n

c/3 o

c o

u

cd h u H

> c3

z

u

T3

o o u

PH

a Z

=3 <

O — CO U -

5 9

a S

a

tn

E LO

E S ro ~ to a

0 CL rr

a a. cc

2 <

CN CC co a in a_

° s ^ £! ? _

cn X

O UJ cc

i C CL CO

CL CO

a CL

cu ce

to

LO in in in LO CN c l d o o

Q Q Q D D

£ Bl

01 c OJ N c ai a

o E o

CO

CN 2

5 12

ID <

to

S 9 CO LL

§ 9 0 )

3

a

D CL CC

a CL cc

0) cc a CL CC

o LU LC

CD CC :c 0 . CO

a CL

cc

in in in in in o rsi o 0 d o

O Q Q Q Q c j i Z Z Z 2 Z cri

L0 O ro

5

o E o m

2. ai _ c > . 0) £ cl J 01 2 tn

2 -

2. a Ul °z

t/i at

o Z

Q Z

£ >, LU X

7/12

Page 28: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

"-1

3-

o ^ Cu . *

C/3

u c

C3

j u

e ca

(73

ao .g 'S

ft n o c3

fc CD

H 2 °° a o > ca i n - - j oi o Pi

u

i -

O

o

o 2

3 <

g LL. o

o 9

Q CL CC

Q CL CC

l£> CU i n CC CN Q m cu ° s K

ci 8 _

a LU cc

ra > "35 DC

cn

> • _

a CL

CC

tn

E ra

CN O r i ca a o o i n ol o r-

Q

ai Q 0) CL "H >. E cu ra ro c CO O <

i n t n d N

O n D l

c ra cn CC LL 0) co

i t a 3 CD

m i n o o

s « o o 5 t n

a Z

< t o

5 9 CO u .

5 S co 0 . tti

•o

<3 Q

0 . t -

b a i ra =

L0 O

E -L i a a_ cc

Q a i in CL T-: O1. ce * - CN

T in CO CN

ss s cc Q 0 -

cc

g i in

o LU CC

CC

IC a. cn

O CL

01

cc

CN i n tn i n co m

O

c ro rn

K LL 01 t n

D 0 .

cc

a CL cc

5 "tu cc Q 0 , LC

m —

Ul

X.

o z

u. •

0 g « s 01 3 r - CC

O O O O O O

r i CN n CN T -

i n s n o r o

O LU CC

o cn to r- -sr a i i n co fN 01 O rvi

a i CC !C CL CO

:c o. CO

a CL

to in to in in CN d d d d

cu or

LU

ca

Q CD g ai CL -̂ E c

_Q) ro

ca c

_Q) C CO o <

o E

CO

TS P. ^ £ - 2 CO

ca h-

0) £= > . LU X

8/12

Page 29: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

o

co U

a

00 C

"5

Pi cd 3

C3 CJ

"5. Q tu

'EL

QJ

I 00

O H

H c g

oo

>

oa O

c o a i n

U ? PH

cn

< co o •tr o LO

^ ° l CM Q

3

a

•— co K CD o cn a

Q a cc

a a. ec

rM CM T- r-

O T - t f LD IfJ O CO CO CO i -rO i— ^ CM CO

CM r-

1 •sr cn

CO t o CD t o

CM O * r

cd CM

-3-(M

i n CM

r-̂ CM

i n CO

i n CM

RP

D

e co co

CM r o CM CM

ighLi

i

LO t-^ CO t q •sr ro

Low

Lirr

-sr tD

CO CO

crj CO

cd CO

ai CO

ro CO

to O N 0) m ro ro CM CO o ^ P) T S CM

in to in in m f i j • • c i o '

•o in E ra

o r̂ -eo o TT cn

so

oL O r -

D cu o ai CL -~ >. E 0) CO ra c cn U <

JD

o

c "

0)

ra DJ x

9/12

Page 30: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

5. i '

O ta o ca

i-J C/l

<Z)

j>> 13 c < la a CD 6 s o t - .

">

ca

Oil

'£ cn

c 3

c-H e o

t cu H

o •n o

H Z

H U

eg

•a O iJ

o p

o

o a. rr

a CL rr

CD or a rr i

o 2 ai

CO

E io < I 2

tn <(

5 t co ZZ* 5 9 CO LL O)

•a <3 Q

o UJ cc

ra >

CC

Cl-CO

0_ CO

a o_

cc

cc

E CD ra =

co o

a CL CC

a CL rr

CM n t n

o 2

< CN

c

CC

tu

cc a a. CC

if

o ui rr

rr i C CL CO

Q

a id

I I ra = to O

ro

a

imit

• CL LC

• CL CC

a •

ra

> to rr a rj-

i n cc cn m o i n I ro Zi

JZ cn X

b ^_ 2 cr im

i

cu _ i CO

o _J

to o

i r t I

5 9 CO LL

5 9 CO LL hi

X I

S Q

O LU CC

ro > ID cc 5C CL LO

O CD

ra

o

a a. LC

a o. cc

CN JN —. Ol CN CO r : o

CO

tu to

CD CC

a CL LC

m m °, 5 9 CO LL

S 9 CO o . ai

x i

5 s

o LU CC

ra >

CC

a. co

CL CO

a CL c

CC

d

o d

to O) m

CC

E tu co •— to O

O CC C3

ro CC CD

CO

o

a Di

'S E

• u

o >• 2 8 Q < 2 -

a

10/12

Page 31: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

0)

3

a

Q D. cc

a CC

i r CD -

cc : a a. cc m

o 10 co

0) ro

Q ui tn O > • 2

< CO

3

T - |

CN Q

g 9

•a o O

CC

cc D

m

tn c

r -ffl

D

0)

o o a a

O u i cc

ITJ S t o CO ff ff co cn co CJI CO CO CO CO CO

o o o o o

in in in in in CN d o d d

Ui cn t-

01

E co ro = w O

co c <

c a i M c 01 ca

a> c 01 N C dl a

a

'io o >• 2 1 0 ST c cu

< CO

CN Q

CD LL

5 9 to 0-

cc

CQ

Q CL CC

a a. cc

5 cc a fl-CC

o o o o o

— I ro ff CN CO CN

E - : : r

a i X

o LU CC

ra > "oi DC

CL LO

CC

i n N- co t o ff ff co o i co o i t o CO CO CO CO

i n m ff o CD o O r r i t - T —

O O O O O

in to in in in CM' d d d d

ro _

h OJ ro -L0 U

±= S 3 > . 01 | i i o £ > . S co h u x

11/12

Page 32: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Hall Environmental Analysis Laboratory

Client Name SJR

Work Order Number 0504087

Checklisl completed by Signature

Sample Receipt Checklist

Dale and Time Received:

Received by GLS

4/8/2005

J lj Dam

Matrix Carrier name UPS

Shipping conlainer/cooler in good condition? Yes 0 No • Not Present

Custody seals inlact on shipping conlainer/cooler? Yes • No • Not Present

Cuslody seals intact on sample bottles? Yes • NoD N/A

Chain of custody present? Yes 0 No •

Chain of custody signed when relinquished and received? Yes 0 N o D

Chain of custody agrees wilh sample labels? Yes 0 N o D

Samples in proper container/bottle? Yes 0 N o D

Sample containers intacl? Yes 0 N o D

Sufficient sample volume for indicated test? Yes 0 N o D

All samples received within holding lime? Yes 0 No D

Water - VOA vials have zero headspace? N o V 0 A v i a , s submitted • Yes 0 NoD

Water - pH acceptable upon receipt? Yes • No D N/A 0

Conlainer/Temp Blank temperature? 3° <T C ± 2 Acceptable

0

If given sufficient lime to cool.

COMMENTS:

Client contacted Date contacted: Person contacted

Contacted by: Regarding

Comments:

Corrective Action

12/12

Page 33: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

(N JO / j aaedspBSH JD sa|qqng Jiy

a

1° • <f CC -3

J <

K

LO

a n

• <DLn

3.8 S

- in

2 ffl CD <n 2 ra

[VOA-iwas] o«B

(VOA) 8092B

(SBD8}s,B0d/S3pP!3S3d LBDB

OJ LO a st­ereo cu id

EjLO Jl _-

[l'0S ' r0d ' ON ON 'IG 'dl su°W

o <tf < |2>

S|B33|AJ a vuoa [HVd JoVNd) 0L8B

(i.gDBpo^aiADGQa

[|/t?OSP°W\l] 903

C U'B Lt? po^aiAJ] Hdl

rjasairj/seg] BSLOB P n qWHdl X X x [A|UQ aujiosBD) Hdl + 381W + X31B

Page 34: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

APPENDIX C

VCM Equipment Data Sheets

Page 35: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

SectionB 2004.qxd 6/26/04 10:37 AM Page B-31

DR 808 & CP 808 Regenerative Blower

ROTRON Regenerative Blowers

FEATURES • Manufactured in the USA - ISO 9001 compliant • CE compliant - Declaration of Conformity on file • Maximum flow: 350 SCFM • Maximum pressure: 116 IWG • Maximum vacuum: 6.9" Hg (93.9 IWG) • Standard motor: 7.5 HP, TEFC • Cast aluminum blower housing, impeller

& cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently

sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty

or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches - air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package

-e

BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (IWVMIN)

2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0

PRESSURE • - M A X PRESSURE

POINT A-7.5 HP B-5.0 HP

A PRESSURE • - M A X PRESSURE

POINT A-7.5 HP B-5.0 HP

\ PRESSURE • - M A X PRESSURE

POINT A-7.5 HP B-5.0 HP A

A

PRESSURE • - M A X PRESSURE

POINT A-7.5 HP B-5.0 HP

r N

N 60 Hz

i B

\ 50 Hz >

t \ \

\ \ 100 150 200 250 300

AIR FLOW RATE (SCFM)

3500

AIR FLOW RATE |m3/mln|

3 4 5 6 7

§ Z Q .

l g 5 2 M

150

100

50

0

10.000

7,000

5,000

2.500

150

100

50

0

100 150 200 250

AIR FLOW RATE (SCFM)

AIR FLOW RATE (SCFM)

AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com

Page 36: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

SectionB 2004.qxd 6/26/04 10:37 AM Page B-32 -Q-

ROTRON Regenerative Blowers

DR 808 & CP 808 Regenerative Blower

DIA. (8) MTG HOLES

ROTATION

2 1/2" NPSC BOTH PORTS

MM TOLERANCES: .XX ±

(UNLESS OTHERWISE NOTED)

MODEL L(IN) L (MM) DR808AY72MX 23.23 590 DR808AY86MX 22.73 577 DR808O89MX 21.08 535 CP808FG72MXLR 22.74 578

Scale CAD drawing available upon request. I

TERMINAL BOX CONNECTION 1.06 INCH DIAMETER ON TEFC MOTORS .75 NPT ON XP MOTORS

SPECIFICATIONS

MODEL DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX Part No. 038722 038724 038725 038734 038728 Motor Enclosure - Shaft Material TEFC-CS TEFC - CS TEFC - CS ChemTEFC-SS TEFC-CS Horsepower 7.5 7.5 5.0 Same as

DR808AY72MX -038722

except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Voltaqe 1 230/460 575 230/460 Same as

DR808AY72MX -038722

except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Phase - Frequency 1 Three - 60 Hz Three - 60 Hz Three - 60 Hz

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Insulation Class 2 F F F

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

NEMA Rated Motor Amps 22.2/11.1 7.2 17.3-15.6/7.8

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Service Factor 1.15 1.15 1.15

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor Locked Rotor Amps 120/60 60 152/76

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Max. Blower Amps 3 27.0/13.5 10.8 17.0/8.5

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Recommended NEMA Starter Size 1/1 1 1/0

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

Shipping Weight 294 Ib (134 kg) 262 Ib (119 kg) 294 Ib (134 kg)

Same as DR808AY72MX -

038722 except add Chemical

Processing (CP)

features from catalog

inside front cover

Same as DR808AY72MX -

038722 except add

High Efficiency motor

1 Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range.

2 Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Pertormance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature.

Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rey. 2/04

AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com Wz&YM

-Q-

Page 37: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

DATA SHEET

USFILTER WESTATES CARBON

ASC-SERIES LOW PRESSURE

LIQUID PHASE ADSORBERS

Benefits and Design Features

• Rugged carbon steel

construction; internally/

externally welded seams

• SSPC-SP5 surface

preparation, fusion bonded

epoxy internal lining; rust

preventative/urethane exterior

coat. (ASC-1000/2000)

• Approved for the transport of

hazardous spent carbon

• ASC- WOO/2000 can be

easily moved with a firklift

• Adapters are available to

reduce the inlet/outlet to

I'FNPT (ASC-2000) and

2" FNPT (ASC-1000/2000)

• Cartridge and bag

prefilters available

• ASC-1000/2000's available

for rental or purchase

Piping Manifold (Optional)

• 273" sch 80 PVC piping and

valves (optional carbon steel

and stainless steel piping)

• Series or parallel operation.

• Clean utility water connection

for manual backflush.

• Sampling ports and pressure

gauges

• Flexible hoses with Kamlock . .

" fittings allow easy installation -

and removal during service

exchange operations. •

OS—

f ,

ASC-Series Adsorbers are designed

to provide uniform water flow for con­

sistent treatment and to ensure efficient

carbon usage. The ASC-Series Adsorbers

can be cost effectively used in applications

including:

• Groundwater remediation

• Wastewater filtration

• Pilot testing

• Leachate treatment

• Dechlorination

• Spill cleanup

Installation, Start Up and Operation

The ASC-Series Adsorbes are shipped

filled with dry activated carbon that must be

properly wetted and deaeraced prior to use.

Your USFilter sales representative can

assist with details on installation, preferred

operating conditions and carbon usage calcu­

lations using our extensive isotherm database.

At the time of purchase or rental of

the ASC-Series Adsorbers, arrangements

should be made for the reactivation of the

spent carbon. USFilter Westates will pro­

vide instructions and assistance to obtain

acceptance of RCRA or non-RCRA spent

carbon for reactivation.

ASC-Series Adsorbers must be drained

and the inlct/oudet plugged prior to ship­

ment. Spent carbon cannot be received until

the acceptance process has been completed.

USi

Page 38: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

DATA SHEET

ASC-SERIES LOW PRESSURE LIQUID PHASE ADSORBERS

SPECIFICATIONS A S C - 2 0 0 A S C - 1 0 0 0 A S C - 2 0 0 0

Dimensions, diameter x overall height 2 2 " x 34" 48" x 56" 48 "x 96"

Vessel Construction Carbon Steel Carbon Steel Carbon Steel

Inlet/Outlet Connection 2" FNPT/2'MNPT 4" FNPT 4" FNPT

Manway Top 18" 16"

Internal Piping PVC PVC PVC Interior Coating Epoxy Fusion Bonded Epoxy Fusion Bonded Epoxy

Exterior Coating Enamel Epoxy/Urethane Epoxy/Urethane

Carbon Bed Volume (cu.ft.) 6.8 34 68

Cross Section (sq.ft.) 2.6 12.3 12.3 Vessel Weight (lbs.):

Shipping (carbon) 250 1890 3190 Operating (approx) 500 4280 7250

Flow, gpm (max) 10 50 100

Pressure, psig (max) 3 25 25

Temperature °F. (max) 140" 140° 140°

Pounds of Carbon 200 1000 2000

Contact time @ max Fbw/min: 5.1 5.1 5.2 BackHush rates (GPM) 15 75 75

For detailed specifications or dimensional information ar drawings, contact your local USFilter Westates sales representative.

ASC-SERIES PRESSURE DROP

0 10 20 30 40 50 60 70 80 90 100 PLOW am

ASC-200 -4 - ASC-1O00 ASC .2000

All information presented herein is believed reli­able and tn accordance with accepted engineering practice. USFilter Westates makes no warranties as to completeness ol' information. Users are respon­sible for evaluating individual product suitability for specific applications. USFilter Westates assumes no liability whatsoever for any special, indirect or consequential damages arising trom the sate, resale or misuse of its products.

USFilter reserves the right to change the specifi­cations referred to in this lireraturc at any time, without prior notice. ASC-Series is a trademark of United States Hirer Corporation or its affiliates.

^^^^£••^49 BBSS wT^BB* HBF

Westates Customer and

Technical Service Network:

Gulf Coast Region

(Louisiana)

Southwest Region

Mid-Atlantic Region

Midwest Region

Northwest Region

Southeast Region

New England Region

800.659.1723

225.744.3153

800.659.1771

800.659.1717

708.345.7290

800.659.1718

225.744.3153

800.659.1717

www. usfilter. com

©2004 United States Fiber Corporation

WS-AQSB-DS-070'i

Page 39: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

SID: 2-0600-8X1 1A | INTL. KE~

TOPVIE\

FRONT VIE^

DESIGNER

AJA

DATE

5-9-01 CHECKER DATE

ENGINEER DATE

MANAGER DATE

FILE:

SCALE: NONE

COMPANY CONFIDENTIAL THIS DOCUMENT AND ALL INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF THE USFILTER AND/OR ITS AFFILIATES ("USF"). THE DESIGN CONCEPTS AND INFORMATION CONTAINED H t K t l N ARE PROPRIETARY TO USF AND ARE SUBMITTED IN CONFIDENCE, THEY ARE NOT TRANSFERABLE AND MUST BE USED ONLY FOR THE PURPOSE FOR WHICH THE DOCUMENT IS EXPRESSLY LOANED. THEY MUST NCT OE DISCLOSED, REPRODUCED. LOANED OR U5ED IN ANY OTHER MANNER WITHOUT THE EXPRESS WRITTEN C0N5ENT OF USF. IN NO EVENT SHALL THEY BE USED IN ANY MANNER DETRIMENTAL TO THE INTEREST OF USF. ALL PATENT RIGHTS ARE RESERVED. UPON THE DEMAND OF USF. THIS DOCUMENT, ALONG WITH ALL COPIES AND EXTRACTS, AND ALL RELATED NOTE-S AND A N A L Y S E S . MUST B E RETURNED TO U S F OR DESTROYED. AS INSTRJCTED BY USF. ACCEPTANCE CF THE DELIVERY OF THIS DOCUMENT CONSTITUTES AGREEMENT TO THESE TERMS AND CONDITIONS.

2" PVC MANIFOLD W/ PIPE RACK GENERAL ASSEMBLY

USFILTER/WESTATES RED BLUFF, CA 1 - 8 0 0 - 7 9 5 - 2 6 6 4

DRAWING

2inPVCmanifoldASS.dwg SHEET

1 OF

Page 40: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 41: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3
Page 42: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Westates 11711 Reading Road Red Bluff, CA 96080

Telephone (530) 527-2664 Facsimile (530) 527-8724

ASC2000 SPECIFICATION SUMMARY

ASC2000 Liquid Phase Adsorption Systems are designed to treat a wide range of contaminated process streams. With piping and valves can be configured for series, parallel, or vessel isolation flows. The adsorber is equipped with a carbon retention system capable of maximum flow rate of 100 gpm.

EACH VESSEL:

Vessel Diameter 48" Side Shell Height 72" Overall Height (Approx.) 8' Total Empty Weight / Vessel 1190 Ibs Maximum Working Pressure 15 psig @ 150 °F Manway at head 18" dia Vessel Volume 660 gal. Carbon Capacity 2000 Ibs. Carbon Bed Volume-Typical 68 Ft3

Maximum Flow 100 gpm Empty Bed Contact Time 5.2 min @ 100gpm Material Carbon Steel Supports Skid mounted Lifting Lifting Lugs Seismic Zone 4 Interior Surface Prep SSPC-SP5 Interior Surface Coating 3M ScotchKote 134, 10-15 mil min dft Exterior Surface Primer Carboline 893 Rust Preventative Epoxy 3 mil min dft Exterior Surface Coating Carboline 134 High Solids Urethane 3mil min dft Standard Color White (Federal Standard 17925)

CONNECTIONS: Influent and Effluent 4" FNPT (SS)

SCREEN: Lateral 4" x 36" PVC V-Wire

WEIGHT:

Shipping weight (vessel) 1,190 Ib Operating weight (vessel & carbon) 3,190 Ib

1-17-03

.VIVENDI water company

Page 43: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

PERFORMANCE CURVES 5 GPM MODEL 5S

FLOW RANGE: 1.2-7 GPM

1400

OUTLET SIZE: 1" NPT NOMINAL DIA. 4'

\-UJ HI

<

X

3 4

CAPACITY (GPM)

41 m

n lit m 1

w M. 1

if w

m *

/if w

f i I f f ,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. \" MOTOR STANDARD, 3450 RPM.

Performance conforms to ISO 9906. 1999 (E) Annex A Minimum submergance is 2 feet.

X-2 C R U N O F O S > V

Page 44: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

MODEL 5S 5 GPM TECHNICAL DATA

DIMENSIONS AND WEIGHTS MOTOR DISCH. DIMENSIONS IN INCHES APPROX.

MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.

5S03-9 A 1/3 4" 1" NPT 22.3 8.8 13.5 3.8 3.9 27

5S05-13 A 1/2 4" 1" NPT 26.4 9.5 16.9 3.8 3.9 31

5S07-18 A 3/4 4" 1" NPT 31.7 10.7 21.0 3.8 3.9 34

5S10-22 A 1 4" 1" NPT 36.1 11.8 24.3 3.8 3.9 42

5S15-26 A 1 1/2 4" 1" NPT 41.2 13.6 27.6 3.8 3.9 46

5S15-31 A 1 1/2 4" 1" NPT 47.1 13.6 33.5 3.8 3.9 58

5S20-39DS A 2 4" 1" NPT 55.2 15.1 40.1 3.8 3.9 65

5S30-48DS A 3 4" 1" NPT 70.0 20.6 45.8 3.8 3.9 90

NOTES: AH modeis suitable for use in 4" wells Weights include pump end with motor in Ibs.

MATERIALS OF CONSTRUCTION COMPONENT SPLINED SHAFT (9-26 Stgs.) CYLINDRICAL SHAFT (31-48 Stgs.)

Check Valve Housing 304 Stainless Steel 304 Stainless Steel

Check Valve 304 Stainless Steel 304 Stainless Steel

Diffuser Chamber 304 Stainless Steel 304 Stainless Steel

Impeller 304 Stainless Steel 304 Stainless Steel

Suction Interconnector 304 Stainless Steel 304 Stainless Steel

Inlet Screen 304 Stainless Steel 304 Stainless Steel

Pump Shaft 304 Stainless Steel 431 Stainless Steel

Straps 304 Stainless Steel 304 Stainless Steel

Cable Guard 304 Stainless Steel 304 Stainless Steel

Priming Inducer 304 Stainless Steel 316 Stainless Steel

Coupling 329/420/431 Stainless Steel 329/420/431 Stainless Steel

Check Valve Seat NBR/304 Stainless Steel NBR/316 Stainless Steel

Top Bearing NBR/304 Stainless Steel NBR/316 Stainless Steel

Impeller Seal Ring NBR/PBT (Valox®) NBR/PPS (Ryton®)

Intermediate Bearings NBR 304 Stainless Steei

Shaft Washer Nol Required LCP (Vectra®)

Split Cone Not Required 304 Stainless Steel

Split Cone Nut Not Required 316 Stainless Steel

NOTES: Specifications subject to change without notice. Valox© is a registered trademark of General Electric Co. Vectra® is a registered trademark of Hoechast Calanese Corporation. Ryton® is a registered trademark of Phillips 66.

c

•D-

A

Fig. A

i

C n U N O F O S > V 4-3

Page 45: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Company name: GRAND CANYON PUMP & SUPPLY Created by: LEW WILLIAMS Phone: (602) 272-7867 Fax: (602) 233-9225 Date: 7/14/2005

08010009 5S03-9

1/1

Page 46: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

PERFORMANCE CURVES 16 GPM MODEL 16S If

FLOW RANGE: 10 -20 GPM

2300

OUTLET SIZE: 1 1 / 4" NPT NOMINAL DIA. 4"

2200

2100

2000

1900

1800

1700

1600

1500

1400

1300

jjj 1200

a 1100 <

x 1000

900

800

700

600

500

400

300

200

100

0

16S100-75DS (10 HP)

16S75-56DS(71/2HP)

316S50-38 (5 HP)

16S30-24 (3 HP)

1 =|16S20-18 (2 HP)

gi6S15-14(1V2HP)

rj16S10-10 (1 HP)B=

16S07-8 (3A

=}16S05-5JVz HP)

OPERATING RANGE: 10 to 20 GPM CAPACITIES BELOW 10 GPM SEE MODEL 10S

3450 RPM 1

f 5 *

4C

o 4 8 10 12

CAPACITY (GPM)

14 16 18 20

•••< f

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 4" MOTOR STANDARD, .5 -5 HP/3450 RPM. 6" MOTOR STANDARD.7.5 -10HP/3450 RPM.

Performance conforms to ISO 9906. 1999 (E) Annex A Minimum submergence is 2 feet.

4-8 G R U N D F O S ' > \

Page 47: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

MODEL 16S 16 GPM TECHNICAL DATA

DIMENSIONS AND WEIGHTS

MODEL NO. FIG. HP

MOTOR

SIZE

DISCH.

SIZE

DIMENSIONS IN INCHES APPROX.

SHIP WT. MODEL NO. FIG. HP

MOTOR

SIZE

DISCH.

SIZE A B C D E

APPROX.

SHIP WT.

16S05-5 A 1/2 4" 1 1/4" NPT 19.7 9.5 10.2 3.8 3.9 27

16S07-8 A 3/4 4" 1 1/4" NPT 23.4 10.7 12.7 3.8 3.9 29

16S10-10 A 1 4" 1 1/4" NP1 26.2 11.8 14.4 3.8 3.9 32

16S15-14 A 1 1/2 4" 1 1/4" NPT 32.8 15.1 17.7 3.8 3.9 36

16S20-18 A 2 4" 1 1/4* HP1 36.0 15.1 20.9 3.8 3.9 40

16S30-24 A 3 4" 1 1/4" NP1 46.5 20.6 25.9 3.8 3.9 64

16S50-38 A 5 4" 1 1/4" HP! 61.1 23.6 37.5 3.8 3.9 94

16S75-56DS* B 7 1/2 6" 1 1/4" MP1 93.0 24.2 68.8 5.4 4.6 220

16S100-75DS* B 10 6" 1 1/4" MP1 109.9 25.4 84.5 5.4 4.6 245

• -E

NOTES: All models suitable for use in 4" wells, unless otherwise noted. Weights include pump end with motor in lbs.. * Built into sleeve 1 '/<" MPT discharge, 6" min. well dia.

C I I

f B

td t l

u • - D -

A A C

Fig. A

MATERIALS OF CONSTRUCTION C O M P O N E N T SPLINED SHAFT (5-24 Stgs.) CYLINDRICAL SHAFT (38 Stgs.) DEEP SET (56-75 Stgs) Check Valve Housing 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Check Valve 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Diffuser Chamber 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Impeller 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Suction Interconnector 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Inlet Screen 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Pump Shaft 304 Stainless Steel 431 Stainless Steel 431 Stainless Steel Straps 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Cable Guard 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Priming Inducer 304 Stainless Steel 304 Stainless Steel 304 Stainless Steel Coupling 316/431 Stainless Steel 316/431 Stainless Steel 329/416 Stainless Steel" Check Valve Seat NBR/304 Stainless Steel NBR/316 Stainless Steel NBR/316 Stainless Steel Top Bearing NBR NBR/316 Stainless Steel NBR/316 Stainless Steel Impeller Seal Ring NBR/PBT (Valox®) NBR/PPS (Ryton®) NBR/PPS (Ryton®) Intermediate Bearings NBR 304 Stainless Steel NBR/316 Stainless Steel Shaft Washer Not Required LCP (Vectra®) LCP (Vectra®) Split Cone Not Required 304 Stainless Steel 304 Stainless Steel Split Cone Nut Not Required 316 Stainless Steel 304 Stainless Steel Sleeve Not Required Not Required 316 Stainless Steel Sleeve Flange Not Required Not Required 304 Stainless Steel Coupling Key Not Required Not Required 302/304 Stainless Steel**

NOTES: Specifications are subject to change without notice. Valox® is a registered trademark of General Electric Co. Vectra® is a registered trademark of Hoechast Calanese Corporation. Ryton® is a registered trademark of Phillips 66. 'Stainless Steel option available. " If using 4" non-standard motors, refer to 329/420/431 Stainless Steel for coupling.

A coupling key is not required.

• D +

Fig.B

rv G R U N D F O S > \

4-9

Page 48: WORK PLANS - New Mexico Department of Energy, Minerals ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/SantaFeEnvironment… · Groundwater pump, MW-48 and DW-2 Grundfos 5S03-9(l/3

Company name: GRAND CANYON PUMP & SUPPLY Created by: LEW WILLIAMS Phone: (602) 272-7867 Fax: (602) 233-9225 Date: 7/14/2005

10010005 16S05-5

H (ft)

16S05-5

60 Hz

o. 0 10 12 14 16 18 Q(USGPM) P2

(HP)

1/1