A PRESENTATION ON
SOLAR WIND HYBRID SYSTEM
BY
![Page 2: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/2.jpg)
BACKGROUND
For remote and inhospitable areas –
Reliable Electricity supply is not available.
![Page 3: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/3.jpg)
BACKGROUND
Severe shortage of man-power in Telephone Exchanges – Small Telephone Exchanges are unmanned. Even refilling of diesel is a problem.
![Page 4: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/4.jpg)
BACKGROUND
Alternative approach is necessary :
Where demand is high. Potential for renewable
energy exists.
![Page 5: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/5.jpg)
BACKGROUND
One such site was identified (in co-ordination with Telecom)
One such site was identified (in co-ordination with Telecom)
KAVUNJI – located at considerable height on a hill top in the Western Ghats range.
![Page 6: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/6.jpg)
BACKGROUND
Reliable Electricity supply not available. Substantial demand for Telecom services. Load Demand of 5KVA (4KW)
![Page 7: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/7.jpg)
BACKGROUND
Solar wind hybrid energy system is proposed.
Solar Modules – 48V DC
1000W wind turbines – 48V DC
![Page 8: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/8.jpg)
BACKGROUND
Battery – 48V deep cycle type for 2 days autonomy.
Controller for Solar DG & wind.
![Page 9: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/9.jpg)
During period of bright sun light (peak summer & winter) solar energy charges the battery and creates enough reserve for darkness.
During monsoons etc., micro - wind generators produce most of the energy since wind speed is high.
MODUS OPERANDI
![Page 10: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/10.jpg)
Hybrid controllers combine both powers to charge the batteries or provide power to inverter. Inverter modulates this to quality power.
MODUS OPERANDI
![Page 11: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/11.jpg)
FEATURES OFSOLAR MODULE
15.64 KWp solar modules configured to 48V DC
Space required – 500 to 550 sq.mts
![Page 12: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/12.jpg)
FEATURES OF WIND GENERATOR
Aerofoil blades (3 Nos.) made of carbon / fibre composite material. Self lubricated ceramic
bearings. Start up wind speed –
3mts/ sec
![Page 13: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/13.jpg)
FEATURES OF WIND GENERATOR
Built in brakes and angle governor to protect at higher wind speeds. Turbine system interfaced
with SMPS based charger. Automatic regulation mode
for over charge protection.
![Page 14: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/14.jpg)
1)M/S. CHLORIDE INTERNATIONAL LTD
KOLKATTA.
OFFERS
2) M/S.RAJESHWARI ELECTRONICS BANGALORE
![Page 15: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/15.jpg)
Exide Batteries group
Experienced since 1992
CHLORIDE INTERNATIONAL LTD
![Page 16: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/16.jpg)
Cost: (Including Erection, Commissioning & Civil works)
a) 1 KW – Rs. 36.2 Lakhs b) 2 KW – Rs. 71.7 Lakhsc) 3 KW – Rs. 1.05 Croresd) 4 KW – Rs. 1.39 Crores
CHLORIDE INTERNATIONAL LTD
![Page 17: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/17.jpg)
Rje IBPS 5000 Hybrid System with 230 Volt AC, Single Phase input / output (Wind + Solar based) to support the load 4 KW for 12 Hours Backup.
M/S.RAJESHWARI ELECTRONICS
![Page 18: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/18.jpg)
Components:
3000W High performance wind Mill System.
4800Wp Multi-crystalline Solar Photovoltaic module.
M/S.RAJESHWARI ELECTRONICS
![Page 19: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/19.jpg)
Components:Imported SMF Lead Acid Battery bank of 12V / 4800AH. High performance Wind and Solar charge controller. Control electronics and other Hardware accessories.
M/S.RAJESHWARI ELECTRONICS
![Page 20: Wind Solar Hybrid ppt](https://reader036.fdocuments.in/reader036/viewer/2022081417/553f7740550346f4018b4800/html5/thumbnails/20.jpg)
Cost: Rs.24,10,000/-
(Including Installation,
Transportation & VAT)
M/S.RAJESHWARI ELECTRONICS
NOTE: Depreciation of 80% is available
for Solar Systems for the first year.