WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct...
Transcript of WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct...
![Page 1: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/1.jpg)
WEATHERTEX CONSTRUCTION DETAIL GUIDE
SELFLOK WEATHERBOARDS
DIRECT FIX
NOVEMBER 2017
![Page 2: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/2.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
SEMI CONCEALED FIX
DETAIL
TRADTIONAL FIX
DETAIL
![Page 3: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/3.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
ON STUD MITRE JOIN DETAIL
ON STUD BUTT JOIN DETAIL
OFF STUD CONCEALED JOINER DETAIL OFF STUD TRADITIONAL JOINER DETAIL
ALUMINIUM LONG VERTICAL DETAIL
![Page 4: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/4.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
SMALL INTERNAL LF CORNER DETAIL
SMALL EXTERNAL LF CORNER DETAIL
SMALL TRADITIONAL EXTERNAL "BOX" CORNER DETAILSMALL TRADITIONAL INTERNAL "W" CORNER DETAIL
![Page 5: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/5.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
END STOP TO MASONRY DETAIL
![Page 6: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/6.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
WINDOW JAMB DETAIL WINDOW HEAD DETAIL
WINDOW SILL DETAIL
![Page 7: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/7.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
METER BOX JAMB
DETAIL
METER BOX HEAD DETAIL
METER BOX SILL DETAIL
![Page 8: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/8.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
DOOR HEADER DETAIL
![Page 9: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/9.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
CONCRETE SLAB
GROUND CLEARANCE DETAIL
OVER DOUBLE BRICK
PIER DETAIL
![Page 10: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/10.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
FLUSH WITH BRICK
VENEER DETAIL
SET BACK OVER BRICK
VENEER DETAIL
![Page 11: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/11.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
PARAPET DETAIL
CANTILEVER ROOF DETAIL
![Page 12: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/12.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
EAVE DETAIL
ROOF CLEARANCE DETAIL
![Page 13: WEATHERTEX CONSTRUCTION DETAIL GUIDE SELFLOK WEATHERBOARDS ... › Technical › Selflok Direct Fix.pdf · direct fix installation - selflok scale: drawn by: checked by: date: drawing](https://reader033.fdocuments.in/reader033/viewer/2022052923/5f043a6e7e708231d40cf199/html5/thumbnails/13.jpg)
DRAWING NAME:
DIRECT FIX INSTALLATION - SELFLOK
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING SET No.:CHECKED BY:
NTS A.MOATE C.O'NEILL 26.10.17 CD-SL-D A3
CLADDING OVER BRICK WITH
TIMBER BATTEN DETAIL
NOTE: VERTICAL BATTENS ONLY
CLADDING OVER MASONRY WITH
METAL TOPHATS DETAIL
NOTE: VERTICAL BATTENS ONLY