Washer disinfectors for laboratory glassware

2

NEW G 7883 MielaborWasher disinfector● Control system: Multitronic Novo

plus with 8 Standard cleaning pro-grammes

● Capacity: 39 narrow necked flasks or 116 pipettes or 1600 test tubes

● H 850 (820), W 600, D 600 mm

Product information Page 9Technical data Page 34

NEW G 7883 CD MielaborWasher disinfector● Features the same as for the G 7883● Integrated hot-air drying unit and

storage drawer for liquid agent sup-ply canisters

● Capacity: 37 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 820 (850), W 900, D 700 (600) mm

Product information Page 9Technical data Page 34

NEW G 7835 CDWasher disinfector● Control system: Freely programm-

able “Profitronic” controls● Integrated hot-air drying unit and

storage drawer for liquid agent sup-ply canisters

● Capacity: 37 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 820 (850), W 900, D 700 (600) mm

Product information Page 11Technical data Page 34

G 7736 CDWasher disinfector● Control system: Freely programm-

able Micro Computer Unit (MCU)● Integrated hot-air drying unit and

storage drawer for liquid agent sup-ply canisters

● Capacity: 66 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 1160, W 900, D 700 (600) mm

Product information Page 17Technical data Page 34

NoteFor details of other Miele washer dis-infectors for laboratory glassware seepage 19 and our brochure for largemachines: Washer disinfectors for laboratoryglassware G 7825–G 7828

Added Miele benefits

3

Innovative market leader● Miele has been at the forefront of de-

veloping cleaning and disinfectingmachines for several decades

● Standardised cleaning processes arean important part of quality assuran-ce GLP or GMP)

Legendary Miele quality● Advanced technology, high quality,

made in Germany● Product development and production

are in accordance with DIN EN ISO9001 quality assurance standards

● Miele have been awarded the inter-nationally acclaimed DIN EN ISO14001 certification for environmentmanagement

Safety● The final rinse is carried out with

purified water for analytically cleanlaboratory glassware

● Injector units for processing narrownecked laboratory glassware

● Process documentation and datanetworking

● Thermal disinfection for hospitallaboratories and the bio-technologyindustry (cleaning and final rinse attemperatures of up to 95°C)

Excellent support from the drawingboard to implementation● Thorough analysis and cost assess-

ment according to your requirements● Detailed planning with drawings● Thorough product specific training

and induction programme

The complete package from onesource● Flexible solutions for professional

and economical preparation oflaboratory glassware

● Baskets and inserts for a wide rangeof glassware

● Practical accessories: Mobile unitsand trolleys, water purification andsoftening systems

Comprehensive support system● Highly trained Miele advisors● Large dealer network● Extensive network of highly qualified

Miele technicians● Maintenance and service contracts

4

Manual versus machine preparationMany laboratories choose to usewasher disinfectors for processing theirlaboratory equipment such as beakers,pipettes, measuring flasks, conical andErlenmeyer fasks, Petri dishes, testtubes etc.

One reason is to avoid the dangerposed by manually handling potentiallydangerous equipment. Broken glassfrom manual cleaning, for instance, cancause dangerous injuries. Infectiousand toxic contaminants pose a healthhazard. Cleaning agents used oftencontain substances that are highly irri-tant.

Because washer disinfectors operateas a closed system with programmesthat run fully automatically, the poten-tial danger to laboratory personnel canbe kept to a minimum This in turnmeans that machine preparation pro-vides personnel with maximum protec-tion.

Machine preparation also ensures thatpreparation can be standardised, vali-dated and documented.

Laboratories use a wide variety ofequipment made from glass, ceramicware and plastic for testing and ana-lysis, for isolating or cleaning sub-stances before, during and after pro-cedures, taking samples etc. Followingon from this cleaning and drying areessential. The cleaning process mustensure that equipment, when usedagain, is not affected by its previoususe.

The scenario will vary a lot from onelaboratory to the next. To establishwhich machines and accessories,cleaning agents, water quality andcleaning programmes are the bestones for your needs the followingaspects need to be considered:

1) ApplicationThe application needs to be divided upinto general areas first (organic, inor-ganic or physical chemistry, biology,microbiology, hospital, pharmaceutical,food industry, or cosmetic industrylaboratory etc.) and then into areas ofapplication or working practice (prepa-ration work, analysis, test samplingetc.). The type of application will alsobe an important deciding factor in thetype of machine and accessories aswell as the cleaning process and selec-tion of cleaning agents required.

2) Laboratory equipmentLaboratory equipment needs to bebroken down into its various compo-nents (beakers, conical flasks, mea-suring flasks and cylinders, pipettes,Petri dishes, test tubes, phials, centri-fugal test tubes etc.), their size or volu-me (1 ml, 500 ml, 1,000 ml) and thenumber of items requiring processing.This information will enable us to prov-ide a detailed quotation of the rightsystem for your requirements.

3) ContaminationKnowledge of physical and chemicalattributes of the types of contaminationthe machine will need to deal with areof particular importance in choosingthe cleaning process and type ofcleaning agent to use.

Physical and chemical properties of acontaminant include, for instance, itssolubility in water under acid, pH-neu-tral or alkaline conditions, its chemicalreaction to hydrolysis or oxidation, itsmelting or softening point, its ability toemulsify, its suspension or dispersingproperties.

4) DisinfectionFor certain applications laboratoryequipment has to be disinfected. Onthe one hand this protects laboratorypersonnel who come into contact withinfectious contaminants at work. Andon the other disinfection prevents bac-terial cross contamination of test sam-ples and instruments in medical labora-tories, hygiene institutes, pharmaceuti-cal laboratories, food and cosmetic in-dustry laboratories.

5) Analytical methodsMethods of analysis used can beinfluenced by particular contaminantsin laboratory glassware. Knowledge ofthese factors can help in selecting thecorrect cleaning agent.

5) Analytical methodsMethods of analysis used can beinfluenced by particular contaminantsin laboratory glassware. Knowledge ofthese factors can help in selecting thecorrect cleaning agent.

6) Analytically cleanEach laboratory will have its own defi-nition of “analytically clean” dependingon the specification, nature and repeat-ability etc. of test methods used. Thewasher disinfector including all its ac-cessories and the cleaning programmeused must be able to achieve cleaningresults that meet the standards requiredby the definition.

SolutionBecause requirements vary from onelaboratory to the next standard solu-tions are often not feasible. More oftenthan not customers require solutionswhich are specific to their particularneeds. By working together with labo-ratory personnel, Miele are able to prov-ide tailor made solutions for individualrequirements.

Miele: The professionals in processing laboratory glassware

5

The Miele systems cover all ofthe following aspects:

● Cleaning, disinfection and drying

● Water preparation

● Detergent recommendations

● Cleaning programmes can beprogrammed and evaluated

Systematic preparation of laboratory glassware

6

Cleaning and dryingThe Miele system consists of thefollowing components:● Washer disinfector● Baskets and inserts for laboratory

equipment

Miele’s G 7883– G 7736 CD washerdisinfectors are single cabinet systemsin which the whole process takes place(wash, rinse and disinfection if appli-cable, followed by drying) in a closedsystem. The cleaning process is car-ried out with injectors using water ba-sed agents. Programmable Profitronicand MCU controls enable programmesto incorporate specific process para-meters (temperature, time, amount ofcleaning agents etc.) for the cleaningtask in hand. With the Multitronic Novoplus controls specific process parame-ters can also be changed in standardcleaning programmes. The controls areable to monitor and maintain the rele-vant process parameters ensuring con-sistent standards of cleanliness. Otherfeatures and options, such as heatingfor the process water, dispensers foracidic, ph-neutral or alkaline cleaningagents, high performance circulationpumps, hot air drying units and auto-matic mobile unit recognition enablecleaning processes to be carried outfully automatically.

Miele offer a wide range of mobile unitsas well as baskets and inserts forlaboratory glassware processing.There are injector jets for pipettes andmeasuring flasks, conical and Erlen-meyer flasks. Injector jets ensurethorough internal cleaning, rinsing anddrying of laboratory glassware. Rotat-ing spray arms ensure thorough exter-nal cleaning and rinsing.

There are special inserts for holdingbeakers, Petri dishes, wide neckedbottles and Erlenmeyer flasks and testtubes securely. These can be placed inthe lower or upper basket. The sprayarms in the machine and in the upperbasket ensure excellent internal andexternal cleaning and rinsing results.

Water preparationVery often different quality water is re-quired for different stages of a pro-gramme, e.g. for the wash and therinse.Usually the beginning of a wash pro-gramme would use softened water(pre-wash, main wash and first rinses).Using softened water prevents lime-scale building up in the machine aswell as unwanted side effects duringthe cleaning process.

Fully demineralised purified water isthen used in the final rinsing stages.This water quality ensures the verybest surface cleanliness of laboratoryglassware. However, to ensure thislevel of cleanliness any contaminationmust first be removed.

Cleaning agentCleaning agents can generally be splitinto 3 groups.● alkaline products● pH neutral products● acidic products

Alkaline cleaning agents are complexmixtures and can contain substancessuch as potassium or sodium hydroxi-de, silicates, cabonates, polycarbona-tes, complex compounds, tensides,enzymes, oxidation agents etc. Thecleaning agent must be selected ac-cording to application and type ofcontamination on the equipment. Forinstance cleaning agents without ten-sides, but preferably with oxidationagents should be used for equipmentused for plant and cell cultures. Ifsamples are being analysed for phos-phorous or phosphates in a laboratory,then the detergent should be phospha-te or phosphonate free.

pH-neutral products generally containtensides, emulsifiers or enzymes. Theyare occasionally used together withalkaline cleaning agents.

Acidic products are based on citric orphosphoric acid. They are often usedfor neutralisation of laboratory equip-ment after cleaning with an alkalineagent. Sometimes it is necessary touse a strong acidic cleaning agent, e.g.to remove limescale deposits fromflasks used for water testing.

Cleaning programmeThe wash programme consists ofseparate stages of a process carriedout in the correct order using theappropriate cleaning agents. To createa suitable programme it is important toknow the physical and chemical pro-perties of the type of contaminationbeing handled.Many contaminants are water solubleor can be dissolved using alkalines(e.g. organic acids) or acids (e.g. amineand some metal oxides).Chemical changes can convert someinsoluble residues into soluble matter(e.g. alkaline hydrolysis of animal fatsand oils into fatty acids and glycerine).Other contaminants are virtually chemi-cally inert and can only be brokendown or emulsified using high tempe-ratures and tensides (e.g. paraffin wax).In certain circumstances dispensingthe incorrect amount of cleaning agent,or running a programme with the pro-cess parameters set in the wrong ordercan lead to unsatisfactory results (e.g.running a hot pre-rinse on items conta-minated blood will cause the blood tocoagulate).

Process assuranceThe aim of all laboratories is to carryout standardised processes which canbe validated. In order to validate pro-cesses and working procedures thesemust be reproducible and be suitablefor being documented. This requires ahigh degree of process assurance.The controls used on Miele washerdisinfectors can monitor validated pro-cedures and working processes, e.g.they can:● control and monitor temperature and

time● control the pressure of the recircula-

tion pump● control and monitor the amount of

water used● monitor level in the supply canisters

and control the amount of liquidagents dispensed

Pre-

was

h

Alka

line

clea

ning

Acid

ic n

eutra

lisat

ion

Rins

eRi

nse

Fina

l rin

se

Dryi

ng

7570

55

20

30

T

t

Example 2

7

The following examples are used toshow two very different cleaning pro-grammes:

Example 1: Water testing laboratoryAnalysis: inorganic materialsLaboratory equipment: Sample bottlesProgramme: acidic pre-wash, alkalinecleaning, acidic neutralisation, 1–2 interim rinses, final rinse with fullyde-mineralised water, drying

Example 2: Institute for cell cultureLaboratory equipment: for cell growthProgramme: pre-wash, alkaline cleaning with oxidation agent, tensideand phosphate free, citric acid basedneutralising agent, 2 interim rinses, finalrinse with purified water, drying

Acid

ic p

re-w

ash

Alka

line

clea

ning

Acid

ic n

eutra

lisat

ion

Rins

e

Rins

e

Fina

l rin

se

Dryi

ng

7570

55

20

30

T

t

Example 1

Laboratory glasswareMost laboratory equipment is madefrom borosilicate glass. Unlike othertypes of glass (except: quartz glass)borosilcate glass has very good physi-cal properties and is highly resistant tochemicals. Fluxing acids and strongsuds will still etch into the surface ofglassware if the concentration, tem-perature and effective periods areincreased. Because of this alkaline cleaningagents are generally used. If at all pos-sible longer holding periods should beavoided at temperatures significantlyhigher than 70°C, and mildly alkalinecleaning agents should be used to re-duce glassware corrosion to a mini-mum. The deterioration rate of glasswaremust be taken into account accordingto its application. For instance etchingon a simple beaker is not a major pro-blem. However, could lead to inaccura-te results with volumatic equipmentsuch as pipettes.

ConclusionIt is essential for laboratories to be pro-vided with customised solutions fortheir specific needs. And this requiresa good working relationship betweenthe user and the manufacturer of thewasher disinfector!Miele’s team of application specialistshave expert knowledge of the differentmachines and mobile units, basketsand inserts required for different uses.And our team of highly trained techni-cians will supervise the installation,commissioning and programming ofthe machine as well as train personnelin its use. Should there be technicaldifficulties at any time we have our ownteam of fully trained service techni-cians.For a professional solution to yourcleaning requirements you can be as-sured that Miele’s application special-ists will provide you with a highly pro-fessional service.

8

G 7883 and G 7883 CDMielabor

G 7883 CD with baskets and inserts for narrow necked glassware

G 7883

The new G 78 generation of washerdisinfectors provide the most profes-sional and economical solution for analytically clean laboratory glasswarein industrial and research laboratories.

Miele has an extensive range of bas-kets and inserts designed to accom-modate a diverse range of laboratoryglassware.

G 7883Washer disinfector● Capacity:

39 narrow necked flasks or 116 pipettes or 1600 test tubes

● H 850 (820), W 600, D 600 mm

G 7883 CDWasher disinfector with drying unit● Capacity:

37 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 820 (850), W 900, D 700 (600) mm

9

Construction● Freestanding front loading machine

with drop down door● Suitable for use freestanding or can

be slotted under a countertop in anexisting laboratory.

● External casing:G 7883 – White (not for G.B.)G 7883 and G 7883 CD – Stainlesssteel

● Space frame construction with sidewall insulation➔ low heat- and noise-emissions➔ easy to recycle

● Wash cabinet and spray arms in highgrade stainless steel

Programme controls● Multitronic Novo plus with 8 standard-

wash programmes (See page 12 for a description of thecontrols, and page 35 for a descrip-tion of the programmes)

Features● Wash cabinet with 2 levels

➔ high capacity● 2 spray arms (3rd spray arm is in the

upper basket)➔ thorough cleaning results

● Direct coupling of upper basket andinjector mobile units to water feed➔ maximum use made of suds solu-tion

● Profi Monobloc Water softener ➔ continual reactivation during thecleaning programme

● Water intake controlled by fly wheelcounter ➔ precise amount of water taken inensures the correct ratio of water tocleaning and disinfecting agents

● 4-fold suds filtration system withwide area filter, coarse filter, glasssplinter filter and micro-fine filter.

● Drying unit/radial fan for hot air dry-ing (G 7883 CD) ➔ thorough internal and externaldrying of laboratory glassware

● Electrical door lock ➔ safety for personnel➔ high process safety

● Access to check and control temper-atures and temperature holdingtimes

Dispenser system● One dispenser each in the door for

powder cleaning agent and liquidagents (rinsing agent) (G 7883/G 7883 CD)

● 1 DOS 10/30 dispenser pump forliquid, acid agents (G 7883/G 7883CD)

● Connection for DOS G 60 dispenserfor liquid cleaning agents (G 7883)

● 1 DOS 60/30 dispenser pump forliquid cleaning agents (G 7883 CD)

● Drawer with 2 x 5 litre containers(G 7883 CD)

Test certificates● Protection classification IP x 1 (drip

water protected)

Certification applied for● VDE● EMV/radio and television suppressed● DVGW● MPG CE 0366

Optional extrasG 7883● Serial interface RS 232 for PC or

printer for process documentation *● AD pump for non-pressurised

demineralised water feed *● Steam condenser/heat exchanger *● 1 dispenser (DOS module G 60) for

liquid cleaning and disinfectingagents

● Plinth, H 300 mm

G 7883 CD● AD pump for non-pressurised

demineralised water feed *● Steam condenser *● Plinth, H 300 mm● Machine lid

* N.B. These features are available asstandard on G.B. machines

See page 34 for technical data

G 7835 CD Washer disinfector

10G 7835 CD with baskets and inserts for pipettes

11

G 7835 CDWasher disinfector with drying unit● Capacity:

37 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 820 (850), W 900, D 700 (600) mm

Construction● Freestanding front loading machine

with drop down door● Suitable for use freestanding or can

be slotted under a countertop in anexisting laboratory.

● External casing: Stainless steel● Space frame construction with side

wall insulation➔ low heat- and noise-emissions➔ easy to recycle

● Wash cabinet and spray arms in highgrade stainless steel

Programme controls● Freely programmable, Profitronic

controls(See page 13 for a description of thecontrols, and page 35 for a descrip-tion of the programmes)

Features● Wash cabinet with 2 levels

➔ high capacity● 2 spray arms (3rd spray arm is in the

upper basket)➔ thorough cleaning results

● Direct coupling of upper basket andinjector mobile units to water feed➔ maximum use made of sudssolution

● Professional Monobloc Water soften-er➔ continual reactivation during thecleaning programme

● Water intake controlled by fly wheelcounter➔ precise amount of water taken inensures the correct ratio of water tocleaning and disinfecting agents

● Steam condenser/Aerosol ➔ prevents emission of steam andhot air into the room➔ can be operated without connec-tion to vent ducting➔ low installation costs

● 4-fold suds filtration system withwide area filter, coarse filter, glasssplinter filter and micro-fine filter.

● Drying unit/radial fan for hot air drying➔ thorough internal and externaldrying of laboratory glassware

● Electrical door lock➔ safety for personnel➔ high process safety

● Access to check and control tem-peratures and temperature holdingtimes

● Sensors in the machine for automaticmobile unit recognition

Dispenser system● 1 DOS 10/30 dispenser pump for

liquid acidic agent● 1 DOS 60/30 dispenser pump for

liquid cleaning agent● Connections for DOS G 60 and DOS

G 10 dispensers● Drawer with 2 x 5 litre containers

Test certificates● Protection classification IP x 1 (drip

water protected)

Certification applied for● VDE● EMV/radio and television suppressed● DVGW● MPG CE 0366

Optional extras● 1 dispenser (DOS module G 60) for

liquid disinfecting agents● 1 dispenser (DOS module G 10) for

liquid rinsing agents● AD pump for non-pressurised

demineralised water feed● Plinth, H 300 mm● Machine lid

See page 34 for technical data

Multitronic Novo plus controls

12

G 7883 and G 7883 CD Washer disinfectors

Controls● Multitronic Novo plus,

some process parameters can bealtered

Programmes● 8 standard-cleaning programmes

Programme control● Single knob programme selector

switch

Display● Programme sequence display● Temperature and programme dura-

tion● Programme end, optical and acous-

tic signal● Service and fault check lights

Control and safety features● 2 NTC probes in the sump for tem-

perature monitoring and redundanttemperature control

● Electric door lock● Programme safety cut out● Programme stopped in event of

power cut

Interface● Serial interface RS 232 for PC or

printer for process documentation(This feature is standard or optionaldepending on country)

● Optical interface for service techni-cian

NoteSee page 35 for a list of programmesand their contents

Multitronic Novo plus

Serial interface for PC or printer connec-tion

Process data reporting using a laptopcomputer

Access point for measuring tempera-ture holding times

Profitronic controls

13

G 7835 CD Washer disinfector

Controls● Freely programmable “Profitronic”

controls

Programmes● 64 Programme slots including:

11 standard cleaning programmes 8 service programmes45 free programme slots

Programme control● User friendly clear text display● 6 languages programmed into the

machine with 1 more programmablelanguage option

Update● New programmes can be program-

med directly into the machine via anoptical interface using a laptop com-puter or PC

Display● The display shows operating and

programming dialogues, programmesequences, temperature, time left,fault messages and number of oper-ating hours

Operational safety● There are 4 user access levels:A: only fixed and free-access pro-

grammes B: all programmes C: automatic mobile unit recognition,

15 different codes can be set.D: full programme range, including pro-

gramming options● Automatic mobile unit recognition

Control and safety features● 2 NTC probes in the sump for tem-

perature monitoring and redundanttemperature control

● Door lock● Peak load cut out

Interface● Serial interface RS 232 for PC or

printer for process documentationand networking

● Optical interface for service techni-cian

NoteSee page 35 for a list of programmesand their contents

Profitronic

Setting the standard

14

Setting the standardThorough cleaning is an essential pre-requisite for preparing analytically cleanlaboratory glassware for reproducableresults. The cleaning and disinfectingprocesses must also be validated inaccordance with Health and Safetyregulations. Programme data andsequences must be documented.

Miele’s latest generation of washer disinfectors comply with the require-ments of EN ISO 15883.

The new generationMiele, as a leading and innovativemanufacturer, has set new standardsfor washer disinfectors with the latestG 78 generation of machines. And indoing so have also been thinking aboutyour pocket: All new machines can beequipped with your existing seriesG 77 machine baskets and inserts – soyou won’t need to replace everything –typically Miele.

The new G 7883, G 7883 CD andG 7835 CD washer disinfectors are asignificant development in the historyof cleaning and disinfecting by machi-

ne. They offer the very best in perfor-mance and reliability – both for thesmall laboratory as well as for labora-tory glassware processing in industrialand research laboratories. The singlecompartment system offered by Mielewasher disinfectors, in which eachmachine cleans, disinfects and dries,has proved itself as particularly flexibleand economical. The automatic mobileunit recognition on the G 7835 CD,further ensures that instruments arecleaned in the correct programme.

Miele’s new washer disinfectorshave an excellent safety record justas you would expect from Miele.

Serial interface for PC or printerconnection for documenting processparameters.

Separate sensors control and monitorthe process to ensure that the machineis able to maintain cleaning, disinfec-ting and final rinse temperature para-meters with even greater precision.

Validation and revalidation is possiblethanks to the controllability of the tem-perature in the wash cabinet and onthe items being processed via themany temperature sensors.

The door is securely locked for thewhole programme duration.It can only be opened at the end of theprogramme if all programme parame-ters have been successfully achieved.

SaferMore economicalBetter results

15

Miele’s new washer disinfectorsare economical to run just as youwould expect from Miele.

The steam condenser with heat ex-changer ensures significantly reducedwater consumption on machines with-out a drying unit.

Thanks to the new Profi Monoblocwater softener reactivation during acleaning programme has led to a re-duction in salt consumption of about50% (in hardness range 5°–15° dH/89-267ppm). A separate reactivationprogramme is not necessary.

If you update your machine to a newermodel you can still use your existingbaskets.

Service friendly and easy to recycleconstruction.

Miele’s new washer disinfectorsprovide excellent cleaning per-formance just as you would expectfrom Miele.

The spray arms have been designed todeliver maximum cleaning power to thesurfaces being washed at the sametime as being economical with theamount water they use.

A high pressure is used for injectormobile units to ensure thorough internalcleaning e.g. of narrow necked glass-ware.

An additional spray arm ensures exter-nal surfaces are also thoroughly clean-ed, especially when injector units arebeing used.

Improved wash results have beenachieved by arranging the jets carefullyand regulating the rotation of the sprayarms.

Greater programming flexibility forcleaning and disinfecting programmeshas been achieved with the newelectronic controls.

16

G 7736 CD Washer disinfector

G 7736 CD

G 7736 CD with baskets and inserts for pipettes

The G 7736 CD washer disinfectorwith integrated drying unit for labora-tory glassware has a well proven trackrecord as an excellent machine fromthe G 77 Generation. The high perfor-mance circulation pump with a waterthroughput level of Ø max. 600 l/min.and a 50% higher water level than theG 78 Generation machines gives thismachine excellent cleaning perform-ance.

The freely programmable Micro Com-puter Unit (MCU) has 64 programmeslots. The user friendly clear text dis-play makes them easy to operate. Andwith a serial interface for connecting aPC or printer process data can bedocumented.

G 7736 CDWasher disinfector with drying unit● Capacity:

66 narrow necked flasks or 96 pipettes or 1600 test tubes

● H 1160, W 900, D 700 (600) mm

17

G 7736 CD Washer disinfector

Construction● Freestanding front loading machine

with drop down door● External casing: Stainless steel● Double skin body

➔ excellent heat and sound insula-tion

● Wash cabinet and spray arms in highgrade stainless steel

Programme controls● Freely programmable, Micro Compu-

ter Unit (MCU) (See page 18 for a description of thecontrols, and page 35 for a descripti-on of the programmes)

Features● Direct coupling of upper basket and

injector mobile units to water feed➔ maximum use made of suds solu-tion

● Large capacity water softener● Steam condenser/Aerosol

➔ prevents emission of steam andhot air into the room➔ can be operated without connec-tion to vent ducting➔ low installation costs

● 4-fold suds filtration system withwide area filter, coarse filter, glasssplinter filter and micro-fine filter.

● Drying unit/radial fan for hot air drying➔ thorough internal and externaldrying of laboratory glassware

Dispenser system● One dispenser each in the door for

powder cleaning agent and liquidagents (rinsing agent)

● 1 DOS 10/30 dispenser pump forliquid acidic agent

● 1 DOS 60/30 dispenser pump forliquid cleaning agent

● Drawer with 2 x 5 litre containers

Test certificates● VDE● EMV/radio and television suppressed● DVGW● MPG CE 0366● Protection classification IP x 1 (drip

water protected)

Optional extras● AD pump for non-pressurised

demineralised water feed● Electric door lock

See page 34 for technical data

18

Micro Computer Unit (MCU) controls

G 7736 CD Washer disinfector

Control system● Micro Computer Unit (MCU), freely

programmable

Programmes● 64 Programme slots including:

11 standard cleaning programmes 4 service programmes49 free programme slots

Programme control● User friendly clear text display● 6 languages programmed into the

machine with 1 more programmablelanguage option

Update● New programmes can be program-

med into the machine directly

Display● The display shows operating and

programming dialogues, programmesequences, temperature, time left,fault messages and number of oper-ating hours

Operational safety3 different keys allow access to the 4switch settings.

I: Only fixed and free-access program-mes

II: All options in access level I, plus:all programmes stored in memoryModification of header paratmeters: Wash and drying temperatures andthe drying duration can be set.

Parameters set in compliance withthe legislation on containing epide-mics (§ 18 IfSG) cannot be modi-fied.

III: All programmes in switch setting IIare accessible, as well as:modification of system parameters:Programme deletion, date and time,reset filter operating times, program-me lock, data transfer, software andhardware update, memory assign-ment and definition of programmeaccess for switch setting I.

IV: All programmes in switch setting IIIare accessible, as well as:modification of service mode: Water intake duration, times fordispenser pumps, water treatment,filter replacement times for the coar-se and particle filters in the dryingunit, disinfection paramenters, oper-ating language, programme runningtimes.

Control and safety features● Door lock● Peak load cut out● Programme stopped in event of

power cut

Interface● Serial interface RS 232 for PC or

printer for process documentation

NoteSee page 35 for a list of programmesand their contents

Micro Computer Unit

19

Washer disinfectors for laboratory glassware

G 7826

G 7828

G 7825 Washer disinfector● Single door machine ● Wash cabinet with drop down door

H 683, W 541, D 617 mm● Control system: Freely programmable

“Profitronic” controls● Capacity per batch

72 narrow necked flasks or 116 pipettes

● External dimensions (Plinth, Washer disinfector, Dryingunit): H 1975, W 900, D 750 mm

● External dimensions (Plinth, Washer disinfector, Dryingunit, Steam condenser): H 2595,W 900, D 750 mm

G 7826 Washer disinfector● As G 7825, but two door through

feed model for separation into clean/unclean side

G 7827 Washer disinfector● Single door machine ● Wash cabinet with lift up door

H 675, W 650, D 800 mm● Control system: Freely programmable

“Profitronic” controls● Capacity per batch

115 narrow necked flasks or 232 pipettes

● External dimensions (Plinth, Washerdisinfector, Drying unit, and if appli-cable Steam condenser):H 2420, W 1150, D 870 mm

G 7828 Washer disinfector● As G 7827, but two door through

feed model for separation into clean/unclean side

For detailed description see thebrochure: Washer disinfectors for labo-ratory glassware G 7825–G 7828