VULCAN™ MFT 24 -...

2
EVALUATION SOLUTION THE ULTIMATE CASED HOLE 16701 GREENSPOINT PARK DRIVE, SUITE #200 HOUSTON TX 77060 1.800.514.8949 MULTI-FINGER TOOL VULCAN™ MFT 24

Transcript of VULCAN™ MFT 24 -...

Page 1: VULCAN™ MFT 24 - scientificdrilling.comscientificdrilling.com/assets/uploads/2017/06/Vulcan™-MFT-24-PF.pdf · evaluation solution the ultimate cased hole 16701 greenspoint park

EVALUATION SOLUTION

THE ULTIMATE CASED HOLE

1 6 7 0 1 G R E E N S P O I NT PA R K D R I V E , S U IT E # 2 0 0 H O U S TO N T X 7 7 0 6 0 1 . 8 0 0 . 5 1 4 . 8 9 4 9

M U LT I - F I N G E R T O O LVULCAN™ MFT 24

Page 2: VULCAN™ MFT 24 - scientificdrilling.comscientificdrilling.com/assets/uploads/2017/06/Vulcan™-MFT-24-PF.pdf · evaluation solution the ultimate cased hole 16701 greenspoint park

THE ULTIMATE CASED HOLE EVALUATION SOLUTION

W W W. S C I E NT I F I C D R I L L I N G . C O M / V U LC A N M F T

Corrosion-Resistant ThroughoutCONSTRUCTION

MATERIALS

330° F (166° C)MAXIMUM TEMPERATURE

1.80 in-4.5 in(45.72 mm-114.3 mm)

WEIGHT

1.75 in (44.45 mm)(Standard)DIAMETER

CaliperCentralizer

Total Length LENGTH

PRODUCT SPECS

MAXIMUM PRESSURE

MEASUREMENT RANGE

12,000 psi 1034.2 bar

35 lbs (15.9 kg)

MAXIMUM LOGGING DURATION @ 0.01s = 7.4 hours

Every 1/100th of a second (0.01 seconds)MINIMUM SAMPLE RATE

±0.02 in (0.508 mm)/0.001 in (0.025 mm)HORIZONTAL ACCURACY/RESOLUTION

0.06 in (1.52 mm)VERTICAL RESOLUTION @30FPM

±50 (50-3550) rotation and inclinationINCLINOMETER/HIGHSIDE RESOLUTION

95 in (2413 mm)24 in (609.6 mm)x2143 in (3632 mm)

1.85 in (47 mm)(Flasked)

37.5 lbs (17.0 kg)

Optional 1.80 in-7.2 in

(45.72 mm-182.88 mm)

High Temp Version428° F (220° C)

Scientific Drilling’s Vulcan™ MFT 24 provides a fit-for-purpose solution in delivering highly accurate measurements for early detection of deformities, corrosion, and leakage in tubing and casing.

With a finger sensor every 15°, faster electronics, and increased memory capacity, the Vulcan™ MFT 24 can sample 100 t imes per second. This al lows for better profil ing measurements, offering detai led results in hours.

+ Tubing and casing evaluation

Deformities, corrosion, and scale detection

ESP and whipstock setting point determination

T A R G E T A P P L I C A T I O N S

+

+

+

+

+

Optimal performance at s ignif icant ly higher temperatures (Up to 428°F/220°C)

Enhanced no-motion auto close safety feature, to assist with tool retrieval

Improved electronics, enabl ing faster logging and increased temperature range

Innovative design, allowing easy on-site maintenance

Full analysis software, providing stat ist ical jo int by jo int analysis and 3D views of pipe

D E L I V E R I N G T H E U LT I M A T E V A L U E

+

+

UPDATED FEBRUARY 2018

M U LT I - F I N G E R T O O L VULCAN™ MFT 24

MEMORYMOTOR LVDT’SCCLBATTERYCALIPERFINGERS