VPE Workbench
description
Transcript of VPE Workbench
-
VPE Workbench 5.6 SP1Product Overview
-
VPE Workbench 5.6 SP1
VPE Workbench 5.6 SP1 contains the following new functionality Production of Fieldbus/Profibus wiring diagrams Production of Instrument hook-up documents Miscellaneous field definition for Process Areas User definable attributes added to Nozzles User definable attributes added to Mechanical
Connections form V-5008 A copy project utility is now available that copies
the project to the same or a different oracle database
-
Fieldbus/Profibus Wiring diagrams
Workflow steps to support fieldbus/profibusdiagram creation Create I/O Types Load / Create the necessary field
devices/instruments within VPE Workbench Create suitable Field Bus Item Types Define field device termination patterns [i.e.
specify the various terminal and field device cable details]
Apply the field device patterns to the necessary instruments
-
Fieldbus/Profibus Wiring diagrams
Workflow steps to support fieldbus/profibusdiagram creation Define field device unit [FDU] templates Define field bus segment templates [Field Bus
Loops - each loop to contain a number of FDUs] Preview / generate actual field bus segments
based on a field bus segment Assign the necessary field instruments Fine tune segments Create diagrams
-
Fieldbus/Profibus Wiring diagrams
Create I/O Types IO types are created in form V-2115
NOTE: The Create Multiple I/O (Y or N) option mustbe set to N for the fieldbus functionality to work.
-
Fieldbus/Profibus Wiring diagrams
Create suitable fieldbus/profibus item types using the Data Management Wizard form V-DMO1
-
Fieldbus/Profibus Wiring diagrams
Define field device termination patterns using form V-2501
-
Fieldbus/Profibus Wiring diagrams
Apply field device termination patterns to instruments using form V-2502
-
Fieldbus/Profibus Wiring diagrams
Define field device unit template using form V-2500
-
Fieldbus/Profibus Wiring diagrams
Define field bus segments (loops) using form V-9061
-
Fieldbus/Profibus Wiring diagrams
Generate tagged field bus segments using form V-9062
Use Preview to see the segments that will be created
-
Fieldbus/Profibus Wiring diagrams
Assign instruments to FDUs in a field bus segment using form V-9063
-
Fieldbus/Profibus Wiring diagrams
Fine tune the field bus segments using form V-2515
-
Fieldbus/Profibus Wiring diagrams
Create Diagrams Templates are created in AutoCAD (2006) and
data designators (placeholders) added to them via the Document Wizard
Fieldbus/Profibus loop diagrams are then generated from the Schematics Workbench
-
Hook-up diagrams
Workflow steps to support hook-up diagram creation Define hook-up template Assign Excel Worksheet to template set Add data designators (placeholders) to the
Worksheet Create hook-up document Allocate parts to hook-up document Assign hook-up document to instruments Generate the document Hook-up parts summary
-
Hook-up diagrams
Define hook-up template
-
Hook-up diagrams
Assign Excel Worksheet to template set via the Document Wizard
-
Hook-up diagrams
Add data designators (placeholders) to the Worksheet
-
Hook-up diagrams
Create hook-up Document
-
Hook-up diagrams
Allocate parts to hook-up Document
-
Hook-up diagrams
Assign hook-up document to instruments
-
Hook-up diagrams
Generate hook-up document
-
Hook-up diagrams
There is also a utility that displays a hook-up document parts summary
-
VPE Workbench 5.6 SP1
VPE Workbench 5.6 SP1 contains improvements to the following existing functionality Enhanced error handling in the Excel Interface
Wizard List of Values value field length in form V-6002
increased from 500 to 4000 characters Field lengths increased for better multi-byte
character support in 366 forms ( for details see http://avevaportal/sites/VPEProdCollateralPublic/Shared%20Documents/VPE%20Workbench%20Presentations%20and%20Movies/VPE%20Workbench%205.6%20SP%201%20Form%20field%20length%20changes.xls)
-
VPE Workbench 5.6 SP1
VPE Workbench 5.6 SP1 contains improvements to the following existing functionality Configurable miscellaneous field tab titles Write API enhancements to the error handling
and only data that has changed since the last import will be updated
Electrical items can now inherit their tag details from the associated powered item
Improvements to the P&ID MTO User role additions to support VPE 7.1
-
VPE Workbench 5.6 SP1
At VPE Workbench 5.6 base release the Oracle infrastructure was changed Only available on Oracle 10g release 1
VPE Workbench 5.6 SP1 also only available on Oracle 10g release 1
-
VPE Workbench 5.6 SP1Fieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsVPE Workbench 5.6 SP1VPE Workbench 5.6 SP1VPE Workbench 5.6 SP1