smartflower POP-e

TECHNICAL DATA

POWER OUTPUT POP APPLICATION AREANominal total cell power 2.31 kWp* Temperature range -20° C to + 40° C

Output through 2-axle tracking 3,400 – 5,700 kWh/a** Humidity 0-95% (non condensing)

Maximum altitude 2,000 m

SYSTEM Maximum sound pressure level < 50 dB (A)outside active zone

Modultype glass/backsheet

Modul power output warranty 25 years on 80% ELECTRICAL CONNECTIONS - INPUT

Module product warranty 10 years Mains connection 400V AC (3P+N+PE)/ 50 Hz

Cell type monocrystalline Nominal current 45 A

Inverter module on-grid, 1-phase, integrated up to 30 m 5 x 10 mm² AWG 8 (flex)

Weight 720 kg from 30 m onwards the local standards must be followed

System warranty 24 months

System selfconsumption per year approx. < 100 kWh

INSTALLATION

4 fastening points Type 2 socket (Mode 3)

Assembly on earth screws or concrete foundation Charging power 11 kW/22 kW (autom. switch)

Charge current 16/32 A (3-phase)

Schuko energy socket (Mode 1) 230 V/13 A (1-phase)

DIMENSIONS - ALL DIMENSIONS IN MM FIXING POINT/ ORIENTATION

TENSILE FORCES***

*** depends on installation site

ELECTRICAL CONNECTIONS - CHARGING STATION (acc. IEC 61851)

*according to STC standards

** depending on the region

Values on payload level (design values) according to Eurocode. Tensile forces calculated on a max. windspeed of 61.2 km/h, panel surface area completely

fanned, security system failure.

Reference according to the assumption of soil class „Aue Löslehm, halbfest“. If soil class in comparable or better screw foundations as mentioned above

are sufficient. If soil class is poorer bigger screw foundations might be necessary.

Back-up fuse of supply line must be 4-pole 50A (10kA peak)

Windguard incl. 10 m cable lenght

Anchor

points

max-

Transv.

(kN)

max.-

Tens.

(kN)

max.

Compr.

(kN)

Appropriate screw

foundation Krinner

Mounting screws for screw foundation -

min. length above screw

Mounting concrete foundation -

threaded rod/anchor - min. lenght

above foundation

1 12.14 30.71 50.00 KSF M 76x1600-M16 M16 - 100 mm M16 -100 mm

2 12.15 30.72 50.01 KSF M 76x1600-M17 M16 - 100 mm M16 -100 mm

3 12.16 30.73 50.02 KSF M 76x1600-M18 M16 - 100 mm M16 -100 mm

4 12.17 30.74 50.03 KSF M 76x1600-M19 M16 - 100 mm M16 -100 mm

CELL CONFIGURATION 6" MODULE 1

CELL CONFIGURATION 6" MODULE 2-11

CELL CONFIGURATION 6" MODULE 12

All values are average values, measured at STC.

All modules are assembled with standard glass – backsheet technology (tempered thin glass with 2.1mm)

MODULE MANUFACTURER

PVT-Austria Photovoltaik Technik GmbH Zlabernerstraße 500, 2135 Neudorf bei Staatz, Austria

SMARTFLOWER MODULE 1

Nominal power Pmpp 239 Wp

Open circuit voltage Uoc 32.90 V

Nominal voltage Umpp 27.90 V

Nominal current Impp 8.60 A

Short circuit current Isc 9.10 A

Maximum power tolerance +/-3%

Current temperature coefficient (Isc) 0.04 %/° C

Voltage temperature coefficient (Uoc) -0.32 %/° C

Power temperature coefficient (Pmpp) -0.40%/°C

NOCT 46° C

Cells 51 monocrystalline solar cells

Cell-dimensions 6" – 156 x 156 mm

Bypass diodes (per module) 3

Connector type & cables H4 connector, 1 x 4 mm2 (0.04 x 0.16 inch²)

Ambient temperature range -25°C - +85° C

Max. system voltage UL 750 Vdc

Serial fuse rating 10A

SMARTFLOWER MODULE 2-11

Nominal power Pmpp 192 Wp

Open circuit voltage Uoc 26.45 V

Nominal voltage Umpp 22.40 V

Nominal current Impp 8.60 A

Short circuit current Isc 9.10 A

Maximum power tolerance +/-3%

Current temperature coefficient (Isc) 0.04 %/° C

Voltage temperature coefficient (Uoc) -0.32 %/° C

Power temperature coefficient (Pmpp) -0.40%/°C

NOCT 46° C

Cells 41 monocrystalline solar cells

Cell-dimensions 6" – 156 x 156 mm

Bypass diodes (per module) 2

Connector type & cables H4 connector, 1 x 4 mm2 (0.04 x 0.16 inch2)

Ambient temperature range -25°C - +85° C

Max. system voltage UL 750 Vdc

Serial fuse rating 10A

SMARTFLOWER MODULE 12

Nominal power Pmpp 155 Wp

Open circuit voltage Uoc 21.30 V

Nominal voltage Umpp 18.05 V

Nominal current Impp 8.60 A

Short circuit current Isc 9.10 A

Maximum power tolerance +/- 3%

Current temperature coefficient (Isc) 0.04 %/°C

Voltage temperature coefficient (Uoc) -0.32 %/°C

Power temperature coefficient (Pmpp) -0.40%/°C

NOCT 46 °C

Cells 33 monocrystalline solar cells

Cell-dimensions 6" – 156 x 156 mm

Bypass diodes (per module) 2

Connector type & cables H4 connector, 1 x 4 mm² (0.04 x 0.16 inch2)

Ambient temperature range -25°C - +85° C

Max. system voltage UL 750 Vdc

Serial fuse rating 10A

INVERTER MODULE DATA

Country Application

DC Input Data

Max. PV-generator power 2800 W

Max. DC voltage 500 V

MPPT voltage range 150–450 V

Max. DC work current 18 A

Number of inputs/MPP trackers 1/1

AC Output Data

Nominal AC power 2500 W

Max. AC power 2750 VA

Max. AC current 12.5 A

Power factor (absolute value) >0.95 (inductive/capacitive)

AC connection on-grid, single phase

Grid voltage range 185-276 V

Grid frequency range 45-55Hz/55-65Hz

Grid regulations / Nominal output voltage

Feed-in Phases

Max. efficiency 97.7 %

European efficiency 96.9 %

MPPT - Efficiency 99.9 %

Safety Equipment

Residual current monitoring unit (RCMU) yes

Grid monitoring with Anti - islanding yes

Normative References

Applicable standards

General Data

Operative temperature range -20/+60° C

Relative humidity 0-98% (non condensing)

IP protection class IP65

Topology transformerless

Standard warranty 10 years

For more information data sheet: www.omnik-solar.com

OMNIK OMNIKSOL-2.5k-TL2-S

Austria, Germany, France, Italy, Spain, Belgium, United Kingdom, Czech Rep.,

Denmark, Holland, Swiss, Poland, Portugal, India, Turkey, Luxemburg, Slovakia,

South Africa, Australia

VDE-AR-N-4105,VDE 0126-1-1, RD1633, C10/11, G83/2, UTE C15-712-1, AS4777,

CEI 0-21, EN50438, NRS 097,VDE0126, N50438, IEC 61683+60068, A1VFR2013 +

VFR2014 IEC61727,IEC62116

IEC 62109-1:2010, E N 62109-1:2010, DIN EN 62109-1:2011,