    Price List 2014-2015

    nFloor-Standing BoilersnWall-Mount BoilersnDomestic Hot Water TanksnSystem TechnologynSolar SystemsnCommercial BoilersnBiomass Boilers

    Effective 1-Sep-14; Revised 19-Feb-15

    1

    USA

  • 7/21/2019 Vi_PriceList1_2-19-15

    2/124

  • 7/21/2019 Vi_PriceList1_2-19-15

    3/124

    Contents

    3 Vitorond 100 Oil-Fired Heating Boilers91 to 245 MBH

    Gas-Fired Condensing Boilers

    12 to 530 MBH

    Indirect-Fired DomesticHot Water Storage Tanks

    Heating System Controls

    Hydronic Heating Accessories

    Solar Collectors

    System Technology

    Simulation Software

    Sectionalcast iron boilers

    91 to 245 MBH

    45 Vitodens 222-F

    Wall-mount boilers

    Floor-standingboilers

    37 to 118 MBH

    12 to 530 MBH

    12 to 125 MBH

    53 Vitocrossal 200

    Steel/stainlesssteel boilers

    59 Vitocell 10061 Vitocell 300

    DHW Pump Module and Electronic Anode

    42 to 119 USG 42 to 119 USG

    67 Vitotronic 200-H74 BMS Gateways75 Low-Loss Headers Transport

    79 Vitosol84 Vitosol 100-F86 Vitosol 200-F88 Vitosol 200-T, SPE90 Vitosol 200-T, SP2A93 System Technology

    100 ESOP NA 4.0

    101 Vitorond 200

    103 Vitorond 200

    105 Vitocrossal 300

    107 KOB Wood Fired Systems

    PyrotPyrotec

    Gas-Fired Condensing Boilers133 to 2245 MBH

    133 to 2245 MBH

    Solar Combi-Packagesplate collectors

    Vacuum tubecollectors

    PAGE

    9 Vitodens 100-W

    17 Vitodens 200-W

    111 Terms and Conditions of Sale, Delivery and Payment

    113 Venting Categories for Gas-Fired Boilers

    114 Viessmann Warranties

    115 Approval and Listing Overview

    121 Viessmann North AmericaContact Information

    Appendix

    This trademark is registered with the U.S. Patent and Trademark Office. 1

    Oil-/Gas-Fired Heating Boilers490 to 4387 MBH

    Gas-Fired Condensing Boilers638 to 3361 MBH

    Sectionalcast iron boilers

    Steel/Stainless Steelboilers

    490 to 1096 MBH

    1255 to 4387 MBH

    638 to 3361 MBH

    Biomass Boilerwith Automatic Fuel Feed System512 to 4268 MBH

    Biomass boilers 512 to 1843 MBH1330 to 4268 MBH

  • 7/21/2019 Vi_PriceList1_2-19-15

    4/1242

  • 7/21/2019 Vi_PriceList1_2-19-15

    5/124

    VITOROND 100

    Vitorond 100

    VR1 Series

    Oil-Fired Boilerfor hydronic heating systemsof cast iron sectional constructionHeating input: 91 to 245 MBH

    27 to 72 kW

    n Eutectoplex heat exchangerfor high operational reliability and along service life.

    n Triple-pass heat exchanger design provides reduced emissions,efficient fuel utilization and low heating costs.

    n Economical and environmentally friendly operation

    n Problem-free cleaning access facilitated by a hinged (left orright), swing-open combustion chamber door providing easyaccess to all three heat exchanger passes from boiler front.

    This trademark is registered with the U.S. Patent and Trademark Office.

    Vitorond 100 with Beckett Burner andHydroLevel Control

    Vitorond 100 with Beckett Burnerand Vitotronic 100 KW10B Control

    3

    Hot water heating boiler 91 to 245 MBH / 27 to 72 kW

  • 7/21/2019 Vi_PriceList1_2-19-15

    6/124

    VITOROND 100

    System Type Control Option

    n 1 heating circuitwithout mixing valve

    HydroLevelthermal reset boiler control

    n 1 heating circuitwithout mixing valve

    n 1 DHW production circuit

    Vitotronic 100, KW10Bfor high temperature heating systems

    n with indoor/outdoor system controln with domestic hot water production and pump outputn with boiler pump outputn with compiled fault output (dry contact)n with 0-10 VDC inputn with adjustable high limit and fixed high limitn with space heating circuit switchn with power indication, call for heat indication,and burner/FHL fault indication

    n with the Viessmann quick-connect plug-in system

    n 1 circuit without mixing valven 1 circuit with mixing valven 1 DHW production circuit

    Vitotronic 200, KW2

    for multiple temperature heating systemsIndoor/outdoor, digital boiler and heating system control

    n with digital tracking of day and weekn with programmable time periods, heatingcurves, temperature setpoints and operating programs

    n with DHW production management (sensor included)n with integrated diagnostic systemn with adjustable high limit and fixed high limitn with FHL test switchn with power indication and sensor/burner fault indicationn with the Viessmann quick-connect plug-in system

    f Boiler standard working pressure: 30 psig; maximum working pressure: 45 psig.

    For 45 psig, order optional pressure relief valve 9549 944,List Price $35..

    An Order No. is supplied for each possible configuration, so all necessary components may easily be ordered together.

    Standard Equipment of Boiler:

    Boiler shell (insulation preinstalled up to size -33), combustion chamber insert, installation fittings c/w 30 psig pressure reliefvalve, drain valve, Tridicator, boiler control (above), burner wiring harness, burner (above) c/w correct oil nozzle

    To order Vitotronic 100, KW10B separately 7834 238, List Price $848.-To order Vitotronic 200, KW2 separately Z001 230, List Price $1863.-To order Vitotronic 300, KW3 separately Z001 231, List Price $2133.-

    OTS

    OTS

    OTS

    n with wall mounting kitn with integrated low-water cut-off function

    4

  • 7/21/2019 Vi_PriceList1_2-19-15

    7/124

    VITOROND 100

    ControlOption

    BurnerOption

    VR1-22 VR1-27 VR1-33 VR1-40 VR1-50 VR1-63 Model No.

    Hydrolevel No Burner VR103191,741.

    VR103201,952.

    VR103212,105.

    VR103222,438.

    VR103232,760.

    VR103243,091.

    Order No.US$

    Hydrolevel Beckett OilforChimney Venting

    VR103072,409.

    VR103082,620.

    VR103092,773.

    VR103103,106.

    VR103113,399.

    VR103123,730.

    Order No.US$

    Hydrolevel Beckett Oilfor Direct Venting

    VR102953,484.

    VR102963,695.

    VR102973,848.

    N/A N/A N/A Order No.US$

    Hydrolevel Riello OilforChimney Venting

    VR103132,638.

    VR103142,849.

    VR103153,020.

    VR103163,353.

    VR103173,675.

    VR103184,235.

    Order No.US$

    Hydrolevel Riello Oilfor Direct Venting

    VR103043,980.

    VR103054,191.

    VR103064,379.

    N/A N/A N/A Order No.US$

    Vitotronic 100,KW10B

    Beckett OilforChimney Venting

    VR102233,280.

    VR102243,491.

    VR102253,644.

    VR102263,975.

    VR102274,268.

    VR102284,599.

    Order No.US$

    Vitotronic 100,KW10B

    Beckett Oilfor Direct Venting

    VR102354,355.

    VR102364,566.

    VR102374,719.

    N/A N/A N/A Order No.US$

    Vitotronic 100,KW10B

    Riello OilforChimney Venting

    VR102293,509.

    VR102303,720.

    VR102313,891.

    VR102324,222.

    VR102334,544.

    VR102345,104.

    Order No.US$

    Vitotronic 100,KW10B

    Riello Oilfor Direct Venting

    VR102384851.

    VR102395062.

    VR102405250.

    N/A N/A N/A Order No.US$

    Vitotronic 200,

    KW2

    Beckett Oilfor

    Chimney Venting

    VR10151

    4,295.

    VR10152

    4,506.

    VR10153

    4,659.

    VR10154

    4,990.

    VR10155

    5,283.

    VR10156

    5,614.

    Order No.

    US$

    Vitotronic 200,KW2

    Beckett Oilfor Direct Venting

    VR101905370.

    VR101915581.

    VR101925734.

    N/A N/A N/A Order No.US$

    Vitotronic 200,KW2

    Riello OilforChimney Venting

    VR101754,524.

    VR101764,735.

    VR101774,906.

    VR101785,237.

    VR101795,559.

    VR101806,119.

    Order No.US$

    Vitotronic 200,KW2

    Riello OilforDirect Venting

    VR102025,866.

    VR102036,077.

    VR102046,265.

    N/A N/A N/A Order No.US$

    Specifications

    MBH Input

    Output

    91

    80

    105

    92

    140

    122

    161

    140

    196

    172

    245

    215

    MBH

    Dimensions Boiler Length(incl. burner)

    Boiler Width

    Boiler Height

    3897619500

    33840

    44111619500

    33840

    44111619500

    33840

    36914

    221/4

    565393/4

    1010

    371/2

    956221/4

    565393/4

    1010

    421/2

    1081221/4

    565393/4

    1010

    inchesmminchesmminchesmm

    Boiler Water Content 9.235

    11.644

    11.644

    12.748

    16.161

    19.373

    USGltr

    Boiler Vent Connection 5 6 inches

    Weight(Shipping) Boiler package 442200

    508230

    508230

    564256

    694315

    822373

    lbskg

    This trademark is registered with the U.S. Patent and Trademark Office. 5

  • 7/21/2019 Vi_PriceList1_2-19-15

    8/124

    VITOROND 100Controls and Accessories

    6

    Controls

    Multiple Boiler Applications

    n 4 boilers max.n 2 heating circuitswith mixing valve max.

    n DHW production

    Vitocontrol-SCascade Control

    n Digital outdoor reset boiler and heating system control.Master control for up to 4 boilers, controlling two heating circuitswith mixing valve and domestic hot water production

    n Each boiler must be equipped with Vitotronic 100, KW10Bn LON-enabled for multiple boiler installations

    7134 6324,148.

    Order No.US$

    Power Supply Adaptor 7134 560174.

    Order No.US$

    LON Communication Modulefor data exchange with Vitocontrol Cascadeor other LON-compatible supervision system.(order 1 unit per boiler)

    7834 357436.

    Order No.US$

    LON Connection Terminalto convert standard LON cable of Vitocontrol-Sto 2-wire communication used in Vitotronic 100.(order 1 unit per Vitocontrol-S)

    7134 631110.

    Order No.US$

    Lead-Lag Expansion Kit (single-stage boilers only)for load-dependent staging of a second boiler.First boiler must be equipped with either Vitotronic 200/300.Second boiler must be equipped with Vitotronic 100 KW10B.

    7133 897611.

    Order No.US$

    Communication

    Output Module (potential-free contact) for burnerstatus, burner failure, high boiler temperature, andexternal (LWCO) alarm via LON.(Order one per boiler; max.:4)

    7134 562695.

    Order No.US$

    Switching Module-V to expand the capabilities of Vitotronic 200 and 300via:

    n remote burner enable and disablen providing for additional heat demand (pool, spa, snowmelt, etc)n using with an external contact or Telephone Interface Module toremotely change heating/operating mode of the heating circuit

    7133 387272.

    Order No.US$

    Telephone Interface Modulenecessary to operate heating system via telephone communication(Switching Module-V also required)

    9543 4211,004.

    Order No.US$

    Expandability

    KM-BUS Expansion Moduleto connect up to 9 devices to the single KM-BUS connectionof the boiler control(Vitotrol, Switching Module-V, etc.)

    7133 393108.

    Order No.US$

    Vitotronic Retrofit Housing for RN (SS) 7133 923344.-

    Order No.US$

    Vitotronic Retrofit Housing for RN (TS) 7133 923483.-

    Order No.US$

    Vitotronic Retrofit Housing for RS/AR 7133 925250.-

    Order No.US$

    Vitotronic Retrofit Housing for VBC/VNE/BEA 7133 922214.-

    Order No.US$

  • 7/21/2019 Vi_PriceList1_2-19-15

    9/124

    This trademark is registered with the U.S. Patent and Trademark Office. 7

    VITOROND 100Controls and Accessories

    Accessories

    Vitorond 100

    Mixing Valve Actuator7542 257

    225.OrderNo.US$

    VR1-22 VR1-27 VR1-33 VR1-40 VR1-50 VR1-63 Model No.

    Boiler Stand for Vitorond 1009" / 250 mm height

    7133 073162.

    7133 074162.

    7133 075162.

    7133 076174.

    Order No.US$

    DHW Pump Modulefor Vitorond 100 with Hydrolevel

    control

    9543 430559.

    Order No.US$

    Wiring Harnessto integrate Tjernlund CombustionAir In-ForcerTM(field supplied) withVitotronic control

    7133 92187.

    Order No.US$

    Carrying Handles 7189 602Net price 78.

    N/A Order No.US$

    Two-Wheel Truckn Special two-wheel truck forViessmann boilers and domestichot water tanks

    9521 645Net price 1,413.

    Order No.US$

    Transport Paneln For use with ViessmannTwo-Wheel Truck (above)

    7198 575Net price 102. N/A Order No.US$

    Remote Controls

    Vitotrol 200 Remote Control for a single heating circuit to program:n daytime temperature and operating program;n with party and energy-saving buttonn with room temperature sensor for room-dependent activationn (for heating circuit with mixing valve only)If the Vitotrol 200 is to operate based upon room-dependent activation, ensure placement in a centralized location.

    7438 363162.

    Order No.US$

    Vitotrol 300A Remote Control for a single heating circuit to program:n daytime and nighttime temperature, DHW temperature, operating and holiday program,party and energy-saving features

    n switching times for heating circuit, DHW tank and recirculation pumpn with illuminated display and textual promptsn with room temperature sensor for room-dependent activation (for heating circuit with mixing valve only)

    If the Vitotrol 300 is to operate based upon room-dependent activation, ensure placement in a centralized location.

    7172 619272.

    Order No.US$

    Room Temperature Sensorif the Vitotrol cannot be installed in a centralized location(must be sold with Remote Control RS, Vitotrol 200, or Vitotrol 300)

    7133 379121.

    Order No.US$

    Mixing Valve Controller Accessory Kitto control a single heating circuit with one mixing valve; includes:

    n mixing valve motor to operate /4to 2/2 Viessmann mixing valvesn supply temperature sensor

  • 7/21/2019 Vi_PriceList1_2-19-15

    10/1248

    NOTES

  • 7/21/2019 Vi_PriceList1_2-19-15

    11/124

    VITODENS 100-WGas-fired, stainless steel condensing boile

    37 to 118 MBH / 11 to 35 kW

    n Lasting Performancewith industry leading Viessmann madeSA240 316 Ti stainless steel Inox-Radial heat exchanger constructedto CSA B51 and ASME Section IV.

    n Low-Emission Combustionwith Viessmann made stainlesssteel MatriX cylinder burner for natural gas or propane. Factorycalibrated.

    n Versatile On-Board Boiler Control interfaces with most externalcontrols. Now with integrated OpenTherm and optional 0-10Vcommunication ability. Outdoor temperature sensor standard.

    n Greater Venting Flexibilitywith increased vent length(up to 200 ft. / 61m) and multiple venting options:- Horizontal or vertical sealed combustion coaxial venting.- Horizontal, vertical or hybrid sealed combustion double-pipe

    venting.- Horizontal or vertical single-wall venting.

    n Altitude Levels of up to 10000 ft. / 3000 m.n Easy Installation, Service and Maintenancewith all pipe connectionslocated at the bottom and serviceable components easily accessiblefrom the front.

    n Limited Lifetime Warrantyin residential applications.

    Vitodens 100-W

    WB1B Series

    Gas-/Propane-Fired Wall-Mounted Condensing Boilerwith modulating stainless steel MatriX cylinder burnerstainless steel Inox-Radial heat exchangerfor room air dependent operationor room air independent operation.

    CombiPLUSKit provides reliable on demand hot water without aDHW tank.Heating input: 37 to 118 MBH

    11 to 35 kW

    CombiPLUSKit

    This trademark is registered with the U.S. Patent and Trademark Office. 9

  • 7/21/2019 Vi_PriceList1_2-19-15

    12/124

    VITODENS 100-W

    Vitodens 100-W

    WB1B26

    WB1B35

    Model No.

    Vitodens 100-WWB1B500 WB1B501 Order No.

    Input Range 37-9111-27

    37-11811-35

    MBHkW

    Output Range34-8310-24

    34-10810-32

    MBHkW

    List Price 2,884. 3,193. US$

    CombiPLUS Kitto provide reliable on demand hotwater without a DHW tankList Price

    7459 305

    515.

    Order No.

    US$

    Specifications WB1B26

    WB1B35

    Dimensionsexcluding LengthCombiPLUS Kit Width

    Height

    14/8360

    15/4400

    28/2725

    14/8360

    15/4400

    28/2725

    inchesmminchesmminchesmm

    Boiler Vent Connectionflue gas / fresh air

    2/8/ 460/100

    2/8/ 460/100

    inchesmm

    Shipping Weightboiler (incl. fittings)excluding vent system

    9543

    9543

    lbskg

    CombiPLUS Kit 31

    14

    lbs

    kgCombiPLUS Kit

    DHW Supply Temperature 14060

    FC

    Continuous draw rate with DCW temp. of 56F / 13C

    99374

    147556

    USG/hL/h

    Continuous draw rate at delta t= 63 F / 35K

    156589

    216800

    USG/hL/h

    f Boiler standard working pressure: 30 psig; maximum: 45 psig. For 45 psig, order optional PRV 9549 944, List Price $35..f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

    Boiler Standard Equipment:Wall-mount boiler and installation fittings c/w 30 psig

    pressure relief valve, pressure gage, gas shut-offvalve, two fill/drain valves, all mounting hardware,supplied analog temperature gaugeoutdoor temperature sensor, and LP conversion kit.

    CombiPLUS Standard Equipment:Plate type heat exchanger,built-in diverting valve,built-in Grundfos 3-speed pump,built-in pressure by-pass valve,built-in water hammer arrester,built-in flow sensor,built-in temperature sensor,supplied with 150 psig pressure relief valve.

    CombiPLUS Kit only for use with boilers

    WB1B500, WB1B501 above!

    10

    f The products above utilize the OpenTherm communication protocol,

    and are therefore onlysuitable for use with Vitodens 100-W.

  • 7/21/2019 Vi_PriceList1_2-19-15

    13/124

    This trademark is registered with the U.S. Patent and Trademark Office. 11

    VITODENS 100-W

    Accessories

    WB1B26

    WB1B35

    Model No.

    Single Boilers

    VersatronikComo OTdigital room temperature control featuring:

    n comfort button to adjust room temperaturen 7-day timer with 3 settings per dayn party mode and energy-saving moden 99-day holiday mode, and more.

    n dimensions: W 5/4 / 146mmH 4 / 102mmD 1/2 / 38mm

    7416 056322.

    Order No.US$

    Versatronik10.WB1DHW pump module to manage domestic hot water production for Vitodens 100-Wwith oneindirect fired storage tank

    n dimensions: W 6/2 / 165mmH 8/4 / 210mm

    D 2/2 / 64mm

    7416 058538.

    Order No.US$

    Multiple Boilers

    Versatronik200to control up to 8 Vitodens 100-W featuring:

    n load-dependent boiler activation and modulation via OpenThermcommunicationn menu-driven LCD displayn indoor/outdoor control operationn control of 2 mixing valve actuatorsn control of 2 circulation pumpsn domestic hot water production

    n

    includes 2 x CoCo OT adaptors 7416 060 (for boilers 1 and 2)n dimensions: W 9/2 / 241mm

    H 8 / 210mm

    D 2 / 64mm

    7416 0591,642.

    Order No.US$

    CoCo OT AdaptorOpenThermadaptor for use with Versatronik200 only(order 1 unit for each of boilers 3 through 8)

    7416 060284.

    Order No.US$

    Mixing Valve Adaptor, 24V or 120Vto operate up to 2 mixing valve actuators. Important: both mixing valve actuators mustbe either24V or 120V - not mixed.Includes 1 strap-on sensor, and 1 immersion sensor.(max. 1 unit per Versatronik200)Viessmann mixing valve actuator: 7542 257

    7416 06185.

    Order No.US$

    Versatronik

    Lago OT for use with Versatronik

    200 onlyn with display for weather-, space-, or time-oriented control of the room temperature

    n dimensions: W 3 / 83mm

    H 3 / 83mm

    D 1/2 / 38mm

    7416 062284. Order No.US$

    Input Module 0-10V OTOpenThermTMinput module, to enable a boiler reset modulecontroller to communicate with the Vitodens 100-W via0-10V (DC) modulating input signal (order 1 until per boiler).

    7249 069256.

    Order No.US$

    f The products above utilize the OpenTherm communication protocol, and are therefore onlysuitable for use with Vitodens 100-W.1 Aquastat may be ordered from Viessmann 9560 985, List Price $142..

    Controls and Accessories

    (max. 1 unit per boiler; compatible with

    outdoor temperature sensor supplied

    with boiler)

    (max. 1 unit per boiler/tank combination;aquastat 1or set-point control must be

    field supplied)

    (max. 2 units per Versatronik200)

  • 7/21/2019 Vi_PriceList1_2-19-15

    14/124

    VITODENS 100-W

    1 Separate circulation pump required for each boiler. Select based upon system pressure drop and flow rate requirement

    See technical data manual. Many other circulation pumps available please inquire.

    12

    Controls and Accessories

    Vitodens 100-W

    Model No.

    Accessories

    Circulation Pump 1

    Boiler delta TGrundfos 3-speed, flangedhousing circulation pump, 115V

    Flange Set, 1/4(Others available, please inquire)

    9560 86040F

    UPS15-58FC225.

    9544 42531.

    Order No.

    ModelUS$

    Order No.US$

    Low-Loss Headers 2

    to decouple high flow rate systems from the boiler loop.

    n Model 80/60 Low-Loss Headerwith insulationMax. flow rate 19.5 USGPM / 4.4 m3/hr

    7498 529290.

    Order No.US$

    n Model 120/80 Low-Loss Headerwith insulationMax. flow rate 35 USGPM / 8 m3/hr

    7498 530435.

    Order No.US$

    Neutralization Unitwith granular neutralization pellets

    7134 231368.

    Order No.US$

    Neutralization Pelletsfor replacement purposes(2 x 2.9lbs / 1.3kg)

    9524 67076.

    Order No.US$

    Service Tool Setfor Vitodens boilers

    Service Kitfor Vitodens boilers models (WB1A, WB1B, WB2A, WB2B)

    9537 070Net Price 121.

    7522 9852,240.

    Order No.US$

    Order No.US$

    2

    For Low-Loss Header sizing, please see Technical Data Manual.

  • 7/21/2019 Vi_PriceList1_2-19-15

    15/124

    This trademark is registered with the U.S. Patent and Trademark Office. 13

    1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.Side wall venting installation mustinclude Viessmann Protective Screen!

    2 Order 1Mounting Clip for eachstraight length of vent pipe installed.f Always follow the installation instructions of the vent manufacturer and of Viessmann.

    VITODENS 100-WCoaxial PP(s) Vent System

    Vent System 1 Vent System Diameter

    60/100 80/125 100/150 Diameter

    Horizontally Vented Maximum Equivalent

    Length (EqL)

    82 / 25

    ft / m

    98 / 30

    ft / m

    118 / 36

    ft / m

    ft. / m

    Room AirIndependent Operation

    Basic Horizontal Vent KitVenting pieces can be orderedindividually, or as a convenientkit using the Order No. to theright; Basic Vent Kit includesoneof each of the itemsnumbered to ,

    and twoMounting Clips .

    7424 119413.

    7424 120460.

    7424 121817.

    Order No.US$

    Boiler Vent Pipe Adaptor60/100

    included with boiler

    Adaptor, coaxial60/100 to 80/125not shown

    Adaptor, coaxial60/100 to 100/150not shown

    N/A

    N/A

    7424 112100.

    N/A

    N/A

    7424 113162.

    Order No.US$

    Order No.US$

    90 ElbowEqL = 1.6ft. / 0.5m

    7424 09467.

    7424 095100.

    7424 096144.

    Order No.US$

    Straight Pipe 2

    3.3ft. / 1m7424 091

    76.7424 092

    100.7424 093

    121.Order No.US$

    Vent Termination2.6ft. / 0.8m

    7424 100144.

    7424 101162.

    7424 102174.

    Order No.US$

    Protective Screen1 7160 61677.

    Order No.US$

    Mounting Clip 2 (each) 7424 10916.10

    7424 11020.

    7424 11126.

    Order No.US$

    Other Available Vent Piecesnot shown in illustration above

    Sliding Coupling1.25ft. / 0.4m

    7424 10667.

    7424 10776.

    7424 10887.

    Order No.US$

    Straight Pipe 2

    1.6ft. / 0.5m7424 088

    52.7424 089

    67.7424 090

    100.Order No.US$

    45Elbow (Set of 2)EqL = 1.0ft. / 0.3m

    7424 097121.

    7424 098135.

    7424 099191.

    Order No.US$

  • 7/21/2019 Vi_PriceList1_2-19-15

    16/124

    1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.2 Order 1Mounting Clip for eachstraight length of vent pipe installed.

    f Always follow the installation instructions of the vent manufacturer and of Viessmann.

    Vent System 1 Vent System Diameter

    60/100 80/125 100/150 Diameter

    Vertically Vented Maximum Equivalent

    Length (EqL)

    82 / 25

    ft / m

    98 / 30

    ft / m

    118 / 36

    ft / m

    ft. / m

    Room AirIndependent Operation

    Boiler Vent Pipe Adaptor60/100

    included with boiler

    Adaptor, coaxial60/100 to 80/125not shown

    Adaptor, coaxial60/100 to 100/150not shown

    N/A

    N/A

    7424 112100.

    N/A

    N/A

    7424 113162.

    Order No.US$

    Order No.US$

    90 ElbowEqL = 1.6ft. / 0.5m

    7424 09467.

    7424 095100.

    7424 096144.

    Order No.US$

    Mounting Clip 2 (each) 7424 10916.10

    7424 11020.

    7424 11126.

    Order No.US$

    Sliding Coupling1.25ft. / 0.4m

    7424 10667.

    7424 10776.

    7424 10887.

    Order No.US$

    Straight Pipe 2

    1.6ft. / 0.5m

    Straight Pipe 2

    3.3ft. / 1m

    7424 088

    52.or

    7424 09176.

    7424 089

    67.or

    7424 092100.

    7424 090

    100.or

    7424 093121.

    Order No.

    US$

    Order No.US$

    45Elbow (Set of 2)EqL = 1ft. / 0.3m

    7424 097121.

    7424 098135.

    7424 099191.

    Order No.US$

    Vent Termination3.9ft. / 1.2m

    7424 103256.

    7424 104350.

    7424 105435.

    Order No.US$

    Roof Flashingand Storm Collar(B-Vent material or better)

    fieldsupplied

    B

    A

    Flue Gas Outlet

    Combustion Air Intake

    VITODENS 100-WCoaxial PP(s) Vent System

    14

  • 7/21/2019 Vi_PriceList1_2-19-15

    17/124

    This trademark is registered with the U.S. Patent and Trademark Office. 15

    VITODENS 100-WVent Systems

    Alternative Vent Systems

    Boiler Flue Gas Connection

    60 80 100 Diameter

    Coaxial Venting 1 see page 14 60/100 80/125 100/150

    direct-connect venting- no special adaptors required

    Protective Screen(for side wall installations only)

    7160 61677.

    Order NoUS$

    Rigid and Flexible PP(s) Venting 1 60 80 100 Diameter

    for Combustion Air Intake 4

    (only if installing ABS, CPVC orPVC piping for combustion air

    intake, please order one CPVC

    Adaptor per boiler)

    Adaptor, CPVC60mm to 2

    Adaptor2 to 3 or 3 to 4

    7134 7697.90

    7134 7697.90

    fieldsupplied

    7134 7697.90

    fieldsupplied

    Order NoUS$

    Order NoUS$

    CPVC Venting 2 2 3 4 Diameter

    for Combustion Air Intake 4and for Flue Gas Outlet

    Adaptor, CPVC60mm to 2

    Adaptor2 to 3 or 3 to 4

    2 x7134 769

    7.90

    2 x7134 769

    7.90

    fieldsupplied

    2 x7134 769

    7.90

    fieldsupplied

    QtyOrder NoUS$

    Order NoUS$

    Stainless Steel Venting 3 3 4 Diameter

    for Combustion Air Intake 4 Adaptor, CPVC60mm to 2

    Adaptor2 to 3 or 3 to 4

    7134 7697.90

    fieldsupplied

    7134 7697.90

    fieldsupplied

    Order NoUS$

    Order NoUS$

    for Flue Gas Outlet PP(s) Adaptorfor stainless steel60mm to 80mm required

    fieldsupplied

    fieldsupplied

    Order NoUS$

    1 Coaxial and PP(s) vent material mustbe ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.2 CPVC vent material mustbe ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.3 Stainless steel vent material mustbe ULC/UL listed for Category IV boilers. Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.4 Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.

    f Always follow the installation instructions of the vent manufacturer and of Viessmann.

  • 7/21/2019 Vi_PriceList1_2-19-15

    18/12416

    NOTES

  • 7/21/2019 Vi_PriceList1_2-19-15

    19/124

    VITODENS 200-WGas-fired, stainless steel condensing boiler

    12 to 530 MBH / 3.5 to 155 kW

    Vitodens 200-W

    B2HA/B2HB Series

    Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operationHeating input: 12 to 530 MBH

    3.5 to 155kW

    For natural gas or liquid propane gas

    n Lasting Performance with industry-leading Viessmannmade SA240 316 Ti stainless steel Inox-Radial heatexchanger constructed to CSA B51 and ASME Section IV.

    n Fast Installation and Reduced Maintenancewith LambdaPro, industry-first intelligent combustion management

    system: Adjusts automatically to gas type and quality.No fuel conversion kit required.

    n Expanded Application Rangewith increased capacity upto 530 MBH (155 kW). Multi-boiler installation up to4240 MBH (1240 kW) with up to 8 boilers(models B2HA 45 - 150).

    n Extremely Quiet Operation; quieter than most refrigerators.

    This trademark is registered with the U.S. Patent and Trademark Office. 17

  • 7/21/2019 Vi_PriceList1_2-19-15

    20/124

    VITODENS 200-W

    Vitodens 200-W

    B2HB19

    B2HB26

    B2HB35

    B2HA45

    B2HA60

    B2HA80

    B2HA100

    B2HA112

    B2HA150

    ModelNo.

    Single or MultipleBoiler Installations

    Vitodens 200-WwithVitotronic 200 HO1B

    B2HB007 B2HB008 B2HB009 B2HAA90 B2HAA91 B2HAA92 B2HAA93 B2HAA94 B2HAA95 Order No.

    List Price

    InputRange

    OutputRange

    NG / LP

    12-683.5-20

    10.9-643.2-19

    3,769.

    19-945.5-27

    17.4-885-26

    3,957.

    19-1255.5-37

    17.4-1175-34

    4,175.

    60-16017-47

    55-14611-43

    4,999.

    60-21217-62

    55-19411-57

    5,796.

    104-28530-83

    95-26028-76

    7,205.

    104-35230-103

    98-33329-96

    8,525.

    113-39933-117

    103-37530-110

    9,572.

    113-53033-155

    103-49530-145

    12,614.

    MBHkW

    MBHkW

    US$

    f Boiler standard working pressure: 30 psig up to B2HA 100 80 psig for B2HA 112/150;

    For 30 psig, order optional PRV 9542 940, List Price $20.For 45 psig, order optional PRV 9549 944, List Price $35..For 60 psig, order optional PRV 9560 183, List Price $35..(sizes B2HA 45 and up only)f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

    Standard Equipment:Wall-mount boiler, Vitotronic 200 HO1B, and installation fittings c/w 30 psig pressure relief valve, outdoor temperature sensor,DHW Sensor, LLH Sensor and Double Pipe Adaptor (for B2HA 45-150) gas shut-off valve, two fill/drain valves, and mounting hardware.

    Technical Data

    Dimensions153/4

    400173/4

    45041

    1040

    153/4

    400173/4

    45041

    1040

    153/4

    400173/4

    45041

    1040

    15380

    19480

    405/8

    1031

    15380

    19480

    405/8

    1031

    21530

    19480

    431/21105

    21530

    19480

    431/21105

    27698

    235/8

    600441/2

    1128

    27698

    235/8

    600441/2

    1128

    inchesmminchesmminchesmm

    Boiler VentConnectionflue gas / fresh air

    60/100 60/100 60/100 80/125 80/125 110/150 110/150 110/150 110/150 mm

    Standard PressureRelief Valve

    30 30 30 30 30 30 30 80 80 psig

    Shipping Weight(incl. fittings)not including

    vent system

    11050

    11050

    11050

    15572

    15572

    19488

    19488

    298135

    298135

    lbskg

    Length

    Width

    Height

    18

  • 7/21/2019 Vi_PriceList1_2-19-15

    21/124

    VITODENS 200-W

    This trademark is registered with the U.S. Patent and Trademark Office. 19

    Vitodens 200-W

    B2HB19

    B2HB26

    B2HB35

    B2HA45

    B2HA60

    B2HA80

    B2HA100

    B2HA112

    B2HA150

    ModelNo.

    Single BoilerInstallationwith Floor Stand

    Vitodens 200-Wwith Vitotronic 200 HO1B

    Input Range

    Output Range

    List Price NG / LP

    B2HB004

    12-683.5-20

    10.9-643.2-19

    3,948.

    B2HB005

    19-945.5-27

    17.4-885-26

    4,136.

    B2HB006

    19-1255.5-37

    17.4-1175-34

    4,354.

    B2HAA99

    60-16017-47

    55-14611-43

    5,178.

    B2HAB00

    60-21217-62

    55-19411-57

    5,975.

    B2HAB01

    104-28530-83

    95-26028-76

    7,384.

    B2HAB02

    104-35230-103

    98-33329-96

    8,704.

    B2HAB03

    113-39933-117

    103-37530-110

    9,773.

    B2HAB04

    113-53033-155

    103-49530-145

    12,815.

    Order No.

    MBHkW

    MBHkW

    US$

    Boiler Standfor free-standinginstallationof a single boilerwithin themechanical room

    7537 684(Applies to B2HB 19-35 and B2HA 45-100)

    7502 558(Appliesto B2HA112-150)

    Order No.

    f Boiler standard working pressure: 30 psig up to B2HA 100 80 psig for B2HA 112/150;

    For 30 psig, order optional PRV 9542 940, List Price $20.

    For 45 psig, order optional PRV 9549 944, List Price $35..For 60 psig, order optional PRV 9560 183, List Price $35..(sizes B2HA 45 and up only)f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

  • 7/21/2019 Vi_PriceList1_2-19-15

    22/124

    VITODENS 200-WAccessories

    20

    Accessories

    Solar DHW Production and Supplemental Heating

    Solar Module SM1Wall-mounted extension module with electronic differential control for dual-coil DHW production and to supplement space heating using solar collectorswhen used with oil/gas-fired heating boilers.

    n operation and display via boiler controln management of two tank systems from one collector fieldn second electronic differential control capabilityn thermostat function for supplemental heating or use of surplus heatn variable speed pump controller for solar circuit pump via pulse-widthcontrol, or for solar circuit pump with PWM-input (mfg Grundfos)

    n includes one tank sensor and one collector sensorn 120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plugn to be used instead of an SCU Solar Controller

    7533 427466.

    Order No.US$

    Order immersion sensor 7438 702 if the following features are required:n for circulation management in systems with 2 storage tanksn for return flow management between boiler and hot water buffer tankn to supply heat to additional accessories

    7438 70287.

    Order No.US$

    Communication

    Vitogate 300, BN/MB Seriesconfigured as compact wall-mount unit-dimensions W 6 H 8 D 8

    -120V, 60Hz, 1A, with 6.5 cord and 120V pkg

    7559 7061,380.-

    Order No.US$

    LON Connecting Cable, 23ft / 7mfor data exchange between controls

    7143 49552.

    Order No.US$

    LON Extension Jackto extend LON Connecting Cable

    7143 49634.

    Order No.US$

    LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes

    7171 78476.

    Order No.US$

    LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end

    7143 49714.

    Order No.US$

    LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LONsystem BUS. For installation inside Vitodens 200-W.

    7179 113328.

    Order No.US$

    Expanded Functions

    Extension Module AM1wall-mounted extension module controls up to 2 of the following circulationpumps:

    n DHW recirculation pumpn DHW production pumpn heating circuit pump for the circuit without a mixing valven 120V, 60Hz, 4A in CSA housing, with 6.5 / 2m cord and 120V plug

    7533 425334.

    Order No.US$

    Each boiler must be equipped with 1X 7179 113 LON Communication Module.

  • 7/21/2019 Vi_PriceList1_2-19-15

    23/124

    This trademark is registered with the U.S. Patent and Trademark Office. 21

    VITODENS 200-WAccessories

    Accessories

    B2HB19

    B2HB26

    B2HB35

    B2HA45

    B2HA60

    B2HA80

    B2HA100

    B2HA112

    B2HA150

    ModelNo.

    Heating Circuit

    Circulation Pump 1

    Boiler delta TGrundfos 3-speed,flangedhousing circulationpump, 115V

    7248 58540F

    UPS 26-99FC391.

    Order No

    ModelUS$

    Flange Set, 1(Others available,please inquire)

    31. For all sizes9544 425

    Order NoUS$

    Low-Loss Headerwith Insulationto decouplehigh flow ratesystems fromthe boiler loop

    80/60

    19.5 USGPM4.4 m3/hr

    7498 529290.

    120/80

    35 USGPM8 m3/hr

    7498 530435.

    Model

    Order NoUS$

    LLH Temperature Sensor(Immersion) to measure thetemperature inside a low-loss

    header

    7179 488121.

    included with boiler

    Order NoUS$

    Neutralization Systemn to neutralize acidic

    condensaten includes pellets

    7134 231368.

    7134 232413.

    7441 823424.

    Order NoUS$

    Neutralization Granulate 9524 6705.7 lbs / 2.6 kg

    76.

    9521 70218 lbs / 8 kg

    89.

    Order No

    US$

    1 Separate circulation pump required for each boiler.Select based upon system pressure drop and flow rate requirement - see Vitodens Technical Data Manual.Many other circulation pumps available - please inquire.

    Max. Flow

    956086040F

    UPS 15-58FC225.

    7441 59640F

    UPS 26-150FC611.-

  • 7/21/2019 Vi_PriceList1_2-19-15

    24/12422

    VITODENS 200-WAccessories

    Accessories

    Low-Temperature Heating Circuits

    Mixing Valve Extension Kit consisting of:

    Mixing Valve Module(KM-BUS participant, wall mount)n including supply temperature sensor (strap-on)n plugs for circulation pump and mixing valve motorn KM-BUS cablen 120V, 60Hz, 2A in CSA housing, with 6.5 / 2m cord and 120V plug

    ZK01105644.

    Order No.US$

    Mixing Valve Motor, 120/1/60n for Viessmann 3- and 4-way mixing valves onlyn including strap-on supply temperature sensor (NTC 10 kOhm)

    Maximum 2 Mixing Valve Extensions per Vitodens boiler in single boilerapplications

    Mixing Valves

    Viessmann 3-Way Mixing Valves /47134 742

    308.

    17134 743

    328.

    1/47134 744

    368.

    1/27134 745

    413.

    27134 746

    506.

    DiaOrder No.US$

    Sensors

    Room Temperature Sensor (wall mount, NTC 10 kOhm)for use with Vitotrol 300A

    Order Room Temperature Sensor if Vitotrol 300A cannot be installedin a centralized location to measure room temperature.

    7438 537108.

    Order No.US$

    DHW Temperature Sensorto measure the temperature inside a domestic hot water storage tank

    Includedwith boiler

    7179 114121.

    Order No.US$

  • 7/21/2019 Vi_PriceList1_2-19-15

    25/124

  • 7/21/2019 Vi_PriceList1_2-19-15

    26/124

  • 7/21/2019 Vi_PriceList1_2-19-15

    27/124

    This trademark is registered with the U.S. Patent and Trademark Office. 25

    VITODENS 200-WCoaxial PP(s) Vent System

    1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.2 Order 1Mounting Clip for eachstraight length of vent pipe installed.

    f Always follow the installation instructions of the vent manufacturer and of Viessmann.

    Room AirIndependent Operation

    Important!As a starting point,please pay attention toboiler vent connection sizeshown above

    Boiler Vent Pipe Adaptor included with boiler

    Order No.

    US$ Flue Transition

    110/150 to 100/150 only

    not shown - requiredB2HA 80...150

    N/A N/A 7424 11584.

    Adaptor, coaxial60/100 to 80/125not shown - only for B2HB 19/26/35

    Adaptor, coaxial60/100 to 100/150not shown - only for B2HB 19/26/35

    Adaptor, coaxial80/125 to 100/150not shown - only for B2HA 45/60

    N/A

    N/A

    N/A

    7424 112100.

    N/A

    N/A

    N/A

    7424 113162.

    7424 114121.

    Order No.

    US$

    Order No.

    US$

    Order No.

    US$

    90 ElbowEqL = 1.6ft. / 0.5m

    7424 09467.

    7424 095100.

    7424 096144.

    Order No.

    US$

    Mounting Clip 2 (each) 7424 10916.10

    7424 11020.

    7424 11126

    Order No.

    US$

    Sliding Coupling1.25ft. / 0.4m

    7424 10667.

    7424 10776.

    7424 10887.

    Order No.

    US$

    Straight Pipe2

    1.6ft. / 0.5m

    Straight Pipe 2

    3.3ft. / 1m

    7424 08852.

    or7424 091

    76.

    7424 08967.

    or7424 092

    100.

    7424 090100.

    or7424 093

    121.

    Order No.

    US$

    Order No.

    US$

    45 Elbow (Set of 2)EqL = 1.0ft. / 0.3m

    7424 097121.

    7424 098135.

    7424 099191.

    Order No.

    US$

    Vent Termination3.9ft. / 1.2m 7424 103256. 7424 104350. 7424 105435.

    Order No.US$

    Roof Flashingand Storm Collar(B-Vent material or better)

    fieldsupplied

    Flue Gas Outlet

    Combustion Air Intake

    Vent SystemDiameter Vertically Vented Maximum Equivalent Length (EqL)

    B2HB

    19

    B2HB

    26

    B2HB

    35

    B2HA

    45

    B2HA

    60

    B2HA

    80

    B2HA

    100

    B2HA

    112

    B2HA

    150

    Model

    No

    60/100 33 ft/10 m

    33 ft/10 m

    33 ft/10 m

    N/A N/A N/A N/A N/A N/A

    80/125 40 ft/12 m

    40 ft/12 m

    40 ft/12 m

    33 ft/10 m

    20 ft/6 m

    N/A N/A N/A N/A

    100/150 50 ft/15 m

    50 ft/15 m

    50 ft/15 m

    43 ft/13 m

    30 ft/9 m

    50 ft/15 m

    50 ft/15 m

    26 ft/8 m

    16 ft/5 m

    B B

    A A

    110

    10

    10

    12

    12

    11

    6

    6

    6

    6

    6

    6

    8

    8

    9 9

    9

    9

    9

    2

    2

    2

    B

    A

    1

    11

  • 7/21/2019 Vi_PriceList1_2-19-15

    28/12426

    VITODENS 200-WAlternative Vent Systems

    Alternative Vent Systems

    Boiler Flue Gas Connection

    60 80 100 Diameter

    Coaxial Venting 1 See previous 2 pages 60/100 80/125 100/150

    Rigid and Flexible PP(s) Venting 1 60 80 100 Diameter

    B2HA/B2HB19 to 150 for Combustion Air Intake 4

    If installing ABS, CPVC or PVCpiping for combustion airintake, please order oneCPVCAdaptor per boiler

    60>27134 769

    7.90

    80>37134 770

    17.10

    110>47134 771

    26.

    Size

    Order No.US$

    B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor80/125 to 80/80

    N/A 7189 822100.

    N/A Order No.US$

    B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor110/150 to 110/110

    N/A N/A 7373 253162.

    Order No.

    US$

    Starter Adaptor 110/100 N/A N/A fieldsupplied

    Order No.

    US$

    CPVC Venting 2 2 3 4 Diameter

    B2HB 19 to 35 for Combustion Air Intake 4and for Flue Gas Outlet

    Adaptor, CPVC60mm to 2

    2 x7134 769

    7.90

    2 x7134 769

    7.90

    2 x7134 769

    7.90

    Qty

    Order No.

    US$

    B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor80/125 to 80/80

    N/A 7189 822100.

    7189 822100.

    Order No.

    US$

    Adaptor, CPVC80mm to 3

    N/A 2 x

    7134 77017.10

    2 x

    7134 77017.10

    Qty

    Order No.US$

    B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor110/150 to 110/110

    N/A N/A 7373 253162.

    Order No.

    US$

    Adaptor, CPVC110mm to 4

    2 x7134 771

    26.

    Qty

    Order No.

    US$

    Stainless Steel Venting 3 3 4 Diameter

    B2HB 19 to 35 for Combustion Air Intake 4 Adaptor, CPVC60mm to 2

    N/A 7134 7697.90

    7134 7697.90

    Order No.

    US$

    for Flue Gas Outlet Starter Adaptor, SS2/3 or 2/4

    N/A fieldsupplied

    fieldsupplied

    Order No.

    US$

    B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor80/125 to 80/80

    N/A 7189 822100.

    N/A Order No.US$

    B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet

    Double-Pipe Adaptor110/150 to 110/110

    N/A N/A 7373 253162.

    Order No.

    US$

    Starter Adaptor, PPs80/3 or 110/4

    N/A fieldsupplied

    fieldsupplied

    Order No.

    US$

    1 Coaxial and PP(s) vent material mustbe ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.2 CPVC vent material mustbe ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.3 Stainless steel vent material mustbe ULC/UL listed for Category IV boilers. Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.4 Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.

    f Always follow the installation instructions of the vent manufacturer and of Viessmann.

  • 7/21/2019 Vi_PriceList1_2-19-15

    29/124

    VITODENS 200-WGas-fired, stainless steel condensing boile

    320 to 4240 MBH / 94 to 1240 kW

    Vitodens 200-W

    B2HA Series, multiple boiler

    Gas-/Propane-Fired Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operation

    For natural gas or propane

    n Viessmann Cascade Control for up to 8 boilers with heating input of320 MBH to 4240 MBH

    n Lasting Performance with industry-leading Viessmannmade SA240 316 Ti stainless steel Inox-Radial heatexchanger constructed to CSA B51 and ASME Section IV.

    n Low Emission Combustion with Viessmann made stainless steel

    MatriX cylinder burner. Factory calibrated.n Powerful and User-Friendly Viessmann Vitotronicon-boardmulti-function outdoor reset boiler and system control for multi-temperature space and DHW heating.

    n Fast Installation and Reduced Maintenancewith LambdaPro, industry-first intelligent combustion managementsystem: Adjusts automatically to gas type and quality.No fuel conversion kit required.

    n Extremely Quiet Operation; quieter than most refrigerators.

    Product may not be exactly as illustrated.

    This trademark is registered with the U.S. Patent and Trademark Office. 27

  • 7/21/2019 Vi_PriceList1_2-19-15

    30/12428

    VITODENS 200-WMultiple Boiler Installations

    Vitodens 200-WMultiple Boiler Installations

    Vitodens 200-W Config No. Configuration Drawing (Top View) Componentry

    2 boilersin- line

    1 Manifold: 7537703 (1)Fittings 1: 7535929 (2)Fittings 2: 7535930 (1)Fittings 3: 7535931 (1)LLH: sized as needed (1)

    3 boilersin- line

    2 Manifold: 7537704 (1)Fittings 1: 7535929 (3)Fittings 2: 7535930 (1)Fittings 3: 7535931 (1)LLH: sized as needed (1)

    4 boilersin- line

    3 Manifold: 7537703 (2)Fittings 1: 7535929 (4)Fittings 2: 7535930 (2)

    Fittings 3: 7535931 (1)LLH: sized as needed (1)

    4 boilersback to back

    4 Manifold: 7537703 (2)Fittings 1: 7535929 (4)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1

    5 boilersback to back

    5 Manifold: 7537703 (1)7537704 (1)

    Fittings 1: 7535929 (5)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)

    LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)

    6 boilersback to back

    6 Manifold: 7537704 (2)Fittings 1: 7535929 (6)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1

    7 boilersback to back

    7 Manifold: 7537703 (2)7537704 (1)

    Fittings 1: 7535929 (7)Fittings 2: 7535930 (3)

    Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1

    8 boilersback to back

    8 Manifold: 7537703 (4)Fittings 1: 7535929 (8)Fittings 2: 7535930 (4)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1

    1 An adaptor set is only required if manifolds are connected directly to 400/200 LLH or larger; or if a Y-piece is connected to a LLHsmaller than 400/200

  • 7/21/2019 Vi_PriceList1_2-19-15

    31/124

    This trademark is registered with the U.S. Patent and Trademark Office. 29

    VITODENS 200-WMultiple Boiler Installations

    Vitodens 200-WMultiple Boiler Installations

    In-line Back to Back

    Vitodens 200-WMultiple Low LossDistribution Manifold(MANIFOLD ONLY)

    2 boilersin-line

    3 boilersin-line

    4 boilersin-line

    4 boilersb-to-b

    5 boilersb-to-b

    6 boilersb-to-b

    7 boilersb-to-b

    8 boilersb-to-b

    ConfigurationDrawing No.

    No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8

    for B2HA 45 ZK012033,958.

    ZK012044,646.

    ZK012057,079.

    ZK012068,912.

    ZK012079,600.

    ZK0120810,528.

    ZK0120912,293.

    ZK0121014,966.

    for B2HA 60 ZK012033,958.

    ZK012114,860.

    ZK012057,079.

    ZK012068,912.

    ZK012129,840.

    ZK0120810,528.

    ZK0121312,963.

    ZK0121415,182.

    for B2HA 80 ZK012154,172.

    ZK012114,860.

    ZK012167,319.

    ZK012179,152.

    ZK0121810,056.

    ZK0121910,744.

    ZK0121312,963.

    ZK0122015,237.

    for B2HA 100 ZK012154,172.

    ZK012215,100.

    ZK012227,535.

    ZK012239,368.

    ZK0121810,056.

    ZK0122410,799

    ZK0122513,018.

    ZK0122616,138.

    for B2HA 112 ZK012154,172.

    ZK011735,316.

    ZK012227,535.

    ZK012239,368.

    ZK0117610,111.

    ZK0122410,799.

    ZK0117813,919.

    ZK0122616,138.

    for B2HA 150 ZK011724,412.

    ZK011735,316.

    ZK011748,542.

    ZK011759,423.

    ZK0117610,111.

    ZK0117711,700

    ZK0117813,919.

    ZK0117916,629.

    *BOILERS not included in the packages listed above

  • 7/21/2019 Vi_PriceList1_2-19-15

    32/124

    Vitodens 200-W

    Sample Dimensions

    n 7 boiler manifoldn size B2HA 150 boiler

    (maximumdimensions given)

    Technical Data

    A B C D LLH Size E F G H

    All dimensions areestimates as at 9/2013

    912314 92

    2352 16

    420 9229 160/80

    200/120

    250/150

    300/200

    400/200

    450/250

    500/300

    19

    486195002155023600

    277003385035900

    45

    1152 67

    1712 75

    1920 inchesmminchesmminchesmminchesmminchesmminchesmminchesmm

    VITODENS 200-WMultiple Boiler Installations

    H

    B C D E

    G

    A

    F

    30

  • 7/21/2019 Vi_PriceList1_2-19-15

    33/124

    Vitodens 200-WMultiple Boiler Installations

    Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-W B2HA 45 B2HAB47 B2HAB48 B2HAB49 B2HAB50 B2HAB51 B2HAB52 B2HAB53 B2HAB54 Order No

    Total Input Total OutputTotal Package List Price

    320292

    16,302.

    480438

    22,174.

    640584

    29,658.

    640584

    31,140.

    800730

    37,012.

    960876

    43,106.

    11201022

    50,392.

    12801168

    57,679.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 45 2xB2HAA90

    3xB2HAA90

    4xB2HAA90

    5xB2HAA90

    6xB2HAA90

    7xB2HAA90

    8xB2HAA90

    QtyBlr ModeOrder No

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No

    KMK BUS Communication ModuleRequired for each ViessmannBoiler controlled by cascadecontrol

    2x7441 586 3x7441 586 4x7441 586 5x7441 586 6x7441 586 7x7441 586 8x7441 586 QtyOrder No

    Circulation PumpUPS 26-99FC 120/1/60

    2x7248 585

    3x7248 585

    4x7248 585

    5x7248 585

    6x7248 585

    7x7248 585

    8x7248 585

    QtyOrder No

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    QtyOrder No

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No

    Manifold 1 1x7537 703

    1x7537 704

    2x7537 703

    1x7537 703

    2x7537 704

    2x7537 703

    4x7537 703

    QtyOrder No

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No

    Low Loss Header 1x7537 705

    160/80

    1x7537 706200/120

    1x7537 707250/150

    QtyOrder No

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No

    Fittings 3 QtyOrder No

    Y-Piece 1x7537 721

    QtyOrder No

    Adapter Set 1x7201 963

    QtyOrder No

    VITODENS 200-W

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with any boilerother than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options (notincluded inPackage Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

    Multiple Boiler Installations

    N/A N/A N/A

    N/A

    N/A

    1x7202 856 Applicable for all sizes

    1x7441 823 Applicable for all sizes

    1x7535 931 Applicable for all sizes

    This trademark is registered with the U.S. Patent and Trademark Office. 31

  • 7/21/2019 Vi_PriceList1_2-19-15

    34/124

    Vitodens 200-WMultiple Boiler Installations

    Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-W B2HA 60

    Total InputTotal OutputTotal Package List Price

    B2HAB55

    424388

    17,816.

    B2HAB56

    636582

    24,643.

    B2HAB57

    848776

    32,687.

    B2HAB58

    848776

    34,169.

    B2HAB59

    1060970

    41,020.

    B2HAB60

    12721164

    47,649.

    B2HAB61

    14841358

    55,892.

    B2HAB62

    16961552

    63,936.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 60 2xB2HAA91

    3xB2HAA91

    4xB2HAA91

    4xB2HAA91

    5xB2HAA91

    6xB2HAA91

    7x7533 377

    8xB2HAA91

    QtyBlr ModelOrder No.

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No.

    KMK BUS Communication Module

    Required for each ViessmannBoiler controlled by cascadecontrol

    2x

    7441 586

    3x

    7441 586

    4x

    7441 586

    4x

    7441 586

    5x

    7441 586

    6x

    7441 586

    7x

    7441 586

    8x

    7441 586

    Qty

    Order No.

    Circulation PumpUPS 26-99FC 120/1/60

    2x7248 585

    3x7248 585

    4x7248 585

    4x7248 585

    5x7248 585

    6x7248 585

    7x7248 585

    8x7248 585

    QtyOrder No.

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    QtyOrder No.

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No.

    Manifold 1 1x7537 703

    1x7537 704

    2x7537 703

    1x7537 703

    2x7537 704

    2x7537 703

    4x7537 703

    QtyOrder No.

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No.

    Low Loss Header 1x7537 705

    160/80

    1x7537 706200/120

    1x7537 707250/150

    1x7537 708300/200

    QtyOrder No.

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No.

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No.

    Fittings 3 Qty

    Order No.

    Y-Piece 1x7537 721

    QtyOrder No.

    Adapter Set 1x7201 963

    QtyOrder No.

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options(notincluded in Package Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

    VITODENS 200-WMultiple Boiler Installations

    N/A

    N/A

    N/A

    N/A N/A

    1x

    7535 931 Applicable for all sizes

    1x7441 823 Applicable for all sizes

    1x7202 856 Applicable for all sizes

    32

  • 7/21/2019 Vi_PriceList1_2-19-15

    35/124

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options(notincluded in Package Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

    Vitodens 200-WMultiple Boiler Installations

    Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-W B2HA 80

    Total InputTotal OutputTotal Package List Price

    B2HAB63

    570520

    20,676.

    B2HAB64

    855780

    28,641.

    B2HAB65

    11401040

    38,241.

    B2HAB66

    11401040

    39,712.

    B2HAB67

    14251300

    47,876.

    B2HAB68

    17101560

    55,841.

    B2HAB69

    19951820

    65,219.

    B2HAB70

    22802080

    74,867.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 80 2xB2HAA92

    3xB2HAA92

    4xB2HAA92

    4xB2HAA92

    5xB2HAA92

    6xB2HAA92

    7xB2HAA92

    8xB2HAA92

    QtyBlr ModelOrder No.

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No.

    KMK BUS Communication Module

    Required for each ViessmannBoiler controlled by cascadecontrol

    2x

    7441 586

    3x

    7441 586

    4x

    7441 586

    4x

    7441 586

    5x

    7441 586

    6x

    7441 586

    7x

    7441 586

    8x

    7441 586

    Qty

    Order No.

    Circulation PumpUPS 26-99FC 120/1/60

    2x7248 585

    3x7248 585

    4x7248 585

    4x7248 585

    5x7248 585

    6x7248 585

    7x7248 585

    8x7248 585

    QtyOrder No.

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    QtyOrder No.

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No.

    Manifold 1 1x7537 703

    1x7537 704

    2x7537 703

    1x7537 703

    1x7537 704

    2x7537 703

    4x7537 703

    QtyOrder No.

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No.

    Low Loss Header 1x7537 706200/120

    1x7537 707

    250/150

    1x7537 708300/200

    1x7537 709400/200

    QtyOrder No.

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No.

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No.

    Fittings 3 Qty

    Order No.

    Y-Piece 1x7537 721

    QtyOrder No.

    Adapter Set 1x7201 963

    QtyOrder No.

    VITODENS 200-WMultiple Boiler Installations

    This trademark is registered with the U.S. Patent and Trademark Office. 33

    1x7202 856 Applicable for all sizes

    1x7441 823 Applicable for all sizes

    1x

    7535 931 Applicable for all sizes

    N/A

    N/A

    N/A

    N/A N/A

  • 7/21/2019 Vi_PriceList1_2-19-15

    36/124

    Vitodens 200-WMultiple Boiler Installations Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-WB2HA 100

    Total InputTotal OutputTotal Package List Price

    B2HAB71

    704666

    23,185.

    B2HAB72

    1056999

    32,626.

    B2HAB73

    14081332

    43,458.

    B2HAB74

    14081332

    44,929.

    B2HAB75

    17601665

    54,148.

    B2HAB76

    21121998

    63,638.

    B2HAB77

    24642331

    74,673.

    B2HAB78

    28162664

    86,138.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 100 2xB2HAA93

    3xB2HAA93

    4xB2HAA93

    4xB2HAA93

    5xB2HAA93

    6xB2HAA93

    7xB2HAA93

    8xB2HAA93

    QtyBlr ModelOrder No.

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No.

    KMK BUS Communication Module

    Required for each ViessmannBoiler controlled by cascadecontrol

    2x

    7441 586

    3x

    7441 586

    4x

    7441 586

    4x

    7441 586

    5x

    7441 586

    6x

    7441 586

    7x

    7441 586

    8x

    7441 586

    Qty

    Order No.

    Circulation PumpUPS 26-99FC 120/1/60

    2x7248 585

    3x7248 585

    4x7248 585

    4x7248 585

    5x7248 585

    6x7248 585

    7x7248 585

    8x7248 585

    QtyOrder No.

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    2x7441 823

    QtyOrder No.

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No.

    Manifold 1 1x7537 703 1x7537 704 2x7537 703 1x7537 703 2x7537 704 2x7537 703 4x7537 703 QtyOrder No.

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No.

    Low Loss Header 1x7537 706200/120

    1x7537 707250/150

    1x7537 708300/200

    1x7537 709400/200

    1x7537 710450/250

    QtyOrder No.

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No.

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No.

    Fittings 3 QtyOrder No.

    Y-Piece 1x7537 721

    QtyOrder No.

    Adapter Set 1x7201 963

    QtyOrder No.

    VITODENS 200-WMultiple Boiler Installations

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options(notincluded in Package Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

    34

    1x7202 856 Applicable for all sizes

    1x7535 931 Applicable for all sizes

    1x7441 823

    N/A

    N/A

    N/A

    N/A N/A

  • 7/21/2019 Vi_PriceList1_2-19-15

    37/124

    Vitodens 200-WMultiple Boiler Installations Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-W B2HA 112Total InputTotal OutputTotal Package List Price

    B2HAB79

    798750

    25,174.

    B2HAB80

    11971125

    35,808.

    B2HAB81

    15961500

    47,435.

    B2HAB82

    15961500

    48,905.

    B2HAB83

    19951875

    59,389.

    B2HAB84

    23942250

    70,006.

    B2HAB85

    27932625

    82,464.

    B2HAB86

    31923000

    94,091.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 112 2xB2HAA94

    3xB2HAA94

    4xB2HAA94

    4xB2HAA94

    5xB2HAA94

    6xB2HAA94

    7x7533 380

    8xB2HAA94

    QtyBlr ModeOrder No

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No

    KMK BUS Communication ModuleRequired for each ViessmannBoiler controlled by cascadecontrol

    2x7441 586

    3x7441 586

    4x7441 586

    4x7441 586

    5x7441 586

    6x7441 586

    7x7441 586

    8x7441 586

    QtyOrder No

    Circulation PumpUPS 26-150F 120/1/60

    2x7441 596

    3x7441 596

    4x7441 596

    4x7441 596

    5x7441 596

    6x7441 596

    7x7441 596

    8x7441 596

    QtyOrder No

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    2x7441 823

    QtyOrder No

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No

    Manifold 1 1x

    7537 703

    1x

    7537 704

    2x

    7537 703

    1x

    7537 703

    2x

    7537 704

    2x

    7537 703

    4x

    7537 703

    Qty

    Order No

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No

    Low Loss Header 1x7537 706200/120

    1x7537 708300/200

    1x7537 709400/200

    1x7537 710450/250

    QtyOrder No

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No

    Fittings 3 QtyOrder No

    Y-Piece 1x7537 721

    QtyOrder No

    Adapter Set 1x7201 963

    QtyOrder No

    VITODENS 200-WMultiple Boiler Installations

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options(notincluded in Package Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

    This trademark is registered with the U.S. Patent and Trademark Office. 35

    1x7202 856 Applicable for all sizes

    1x7535 931 Applicable for all sizes

    1x7441 823

    N/A

    N/A

    N/A

    N/A N/A

    1x7537 707250/150

  • 7/21/2019 Vi_PriceList1_2-19-15

    38/124

    Vitodens 200-WMultiple Boiler Installations

    Number of Boilers in Each Package

    2 3 4 4 5 6 7 8

    Vitodens 200-W B2HA 150

    Total InputTotal OutputTotal Package List Price

    B2HAB87

    1060990

    31,598.

    B2HAB88

    15901485

    45,107.

    B2HAB89

    21201980

    60,549.

    B2HAB90

    21201980

    61,578.

    B2HAB91

    26502475

    75,291.

    B2HAB92

    31802970

    89,434.

    B2HAB93

    37103465

    104,158.

    B2HAB94

    42403960

    119,337.

    MBHMBH

    Total Package consists of the items listed below

    Vitodens 200-W B2HA 150 2xB2HAA95

    3xB2HAA95

    4xB2HAA95

    4xB2HAA95

    5xB2HAA95

    6xB2HAA95

    7xB2HAA95

    8xB2HAA95

    QtyBlr ModelOrder No.

    Vitotronic 300-K, MW2CCascade control for up to 8 boilers

    QtyOrder No.

    KMK BUS Communication ModuleRequired for each Viessmann Boilercontrolled by cascade control

    2x7441 586

    3x7441 586

    4x7441 586

    4x7441 586

    5x7441 586

    6x7441 586

    7x7441 586

    8x7441 586

    QtyOrder No.

    Circulation PumpUPS 26-150F 120/1/60

    2x7441 596

    3x7441 596

    4x7441 596

    4x7441 596

    5x7441 596

    6x7441 596

    7x7441 596

    8x7441 596

    QtyOrder No.

    Neutralization SystemTo neutralize acidic condensate,includes pellets

    1x7441 823

    2x7441 823

    QtyOrder No

    CSD-Conversion Kit 2x7841 861

    3x7841 861

    4x7841 861

    4x7841 861

    5x7841 861

    6x7841 861

    7x7841 861

    8x7841 861

    QtyOrder No.

    Gas Pressure Switch 2x7842 160

    3x7842 160

    4x7842 160

    4x7842 160

    5x7842 160

    6x7842 160

    7x7842 160

    8x7842 160

    QtyOrder No.

    Manifold 1 1x7537 703

    1x7537 704

    2x7537 703

    1x7537 703

    2x7537 704

    2x7537 703

    4x7537 703

    QtyOrder No.

    Manifold 2 1x7537 704

    1x7537 704

    QtyOrder No.

    Low Loss Header 1x7537 707250/150

    1x7537 708300/200

    1x7537 709400/200

    1x7537 710450/250

    1x7537 711500/300

    QtyOrder No.

    Fittings 1 2x7535 929

    3x7535 929

    4x7535 929

    5x7535 929

    6x7535 929

    7x7535 929

    8x7535 929

    QtyOrder No.

    Fittings 2 1x7535 930

    2x7535 930

    3x7535 930

    4x7535 930

    QtyOrder No.

    Fittings 3 QtyOrder No.

    Y-Piece 1x7537 721

    QtyOrder No.

    Adapter Set 1x7201 963

    QtyOrder No.

    VITODENS 200-WMultiple Boiler Installations

    1x7202 856 Applicable for all sizes

    1x7535 931 Applicable for all sizes

    N/A

    N/A

    N/A N/A

    N/A N/A

    36

    fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.

    Other Equipment / Options(notincluded in Package Standard Equipment):

    n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up

  • 7/21/2019 Vi_PriceList1_2-19-15

    39/124

    VITODENS 200-W

    This trademark is registered with the U.S. Patent and Trademark Office. 37

    Multiple Boiler InstallationsSystem Components (If Rack Ordered Separately

    Vitodens 200-W Number of Boilers in Each Package

    2 3 4 5 6 7 8

    B2HA 45 B2HAB0511,564.-

    B2HAB06

    16,434.-B2HAB07

    21,304.-B2HAB08

    26,173.-B2HAB09

    31,043.-B2HAB10

    35,913.-B2HAB11

    40,783.-Order No.

    US$

    B2HA 60 B2HAB1212,984.-

    B2HAB1318,706.-

    B2HAB1424,332.-

    B2HAB1529,959.-

    B2HAB1635,586.-

    B2HAB1741,213.-

    B2HAB1846,840.-

    Order No.

    US$

    B2HA 80 B2HAB1915,756.-

    B2HAB2022,721.-

    B2HAB2129,687.-

    B2HAB2236,652.-

    B2HAB2343,617.-

    B2HAB2450,583.-

    B2HAB2557,548.-

    Order No.

    US$

    B2HA 100 B2HAB2618,264.-

    B2HAB2726,483.-

    B2HAB2834,703.-

    B2HAB2942,922.-

    B2HAB3051,141.-

    B2HAB3159,361.-

    B2HAB3267,580.-

    Order No.

    US$

    B2HA 112 B2HAB3320,253.-

    B2HAB3429,467.-

    B2HAB3538,681.-

    B2HAB3647,895.-

    B2HAB3757,109.-

    B2HAB3866,323.-

    B2HAB3975,537.-

    Order No.

    US$

    B2HA 150 B2HAB40

    26,033.-

    B2HAB41

    38,137.-

    B2HAB42

    50,241.-

    B2HAB43

    62,345.-

    B2HAB44

    74,449.-

    B2HAB45

    86,553.-

    B2HAB46

    98,657.-

    Order No.

    US$

    Standard Equipment:Vitodens 200 wall-mount boilersInstallation fittings with 30 psig pressure relief valveDouble Pipe AdaptorsOutdoor temperature sensorDHW sensorLLH sensorfill/drain valvesmounting hardwareGas Pressure Switch (for B2HA 112 and B2HA 150)Vitotronic 300-K MW2C cascade controlKMK- BUS communication module

  • 7/21/2019 Vi_PriceList1_2-19-15

    40/12438

    Wall-Mounted Master Boiler Control

    Vitotronic 300-K, MW2C Series Color touch screen

    wall-mounted, digital indoor/outdoor master boiler and heating system controlfor up to 8Vitodens 200-W boilers

    n with domestic hot water production features, including sensorn including strap-on supply temperature sensorfor low-loss header (NTC 10 kOhm)

    n capable of communication with Vitodens 200-W via KM-BUSprotocoln capable of communication with Vitotronic 200-H via LON-BUSif equippedwith LON Communication Module (optional)With electric circuit board for the 2. and 3. heating circuit with mixing valve

    7202 856

    1913.

    Order No.

    US$

    Communication

    KMK Communication Moduleelectronic circuit board enabling data communication via Viessmann KMKsystem BUS between Vitotronic 300-K and Vitodens 200-W.For installation inside Vitodens 200-W.

    Order one unit per Vitodens 200-W.

    7441 586135.

    Order No.US$

    LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LONsystem BUS. For installation inside Vitotronic 300-K, MW2B.

    7172 174308.

    Order No.US$

    LON Connecting Cable, 23ft / 7mfor data exchange between controls

    7143 49552.

    Order No.US$

    LON Extension Jackto extend LON Connecting Cable

    7143 49634.

    Order No.US$

    LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes

    7171 78476.

    Order No.US$

    LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end

    7143 49714.

    Order No.US$

    KM-BUS Expansion Moduleto connect between 2 and 9 additional devices to the KM-BUS

    7133 393108.

    Order No.US$

    Extension Modulen wall-mounted extension module controls up to 2 circulation pumpsn *boiler set point temperaturen 1 Analog input (0-10V)n 3 Digital Inputsn 1 Output contact (potential-free)n Refer to manual for additional info

    7533 426348.

    Order No.US$

    Extension Module AM1

    wall-mounted extension module controls up to 2 circulation pumps

    7533 425

    334.

    Order No.

    US$

    Solar Module SM1wall-mounted extension module with electronic differential control foruse with solar collectors when used with Vitodens boilers.

    n heating output balancing and diagnostic systemn operation and display via boiler controln management of two tank systems from one collector fieldn second electronic differential controln thermostat function for supplemental heating or use of surplus heatn variable speed pump controller for solar circuit pump via pulse-widthcontrol, or for solar circuit pump with PWM-input (mfg Grundfos)

    n includes one tank sensor and one collector sensorn 120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plugn To be used instead of an SCU Solar Controller

    7533 427466.

    Order No.US$

    VITODENS 200-WMultiple Boiler InstallationsSystem Components (If Rack Ordered Separately)

  • 7/21/2019 Vi_PriceList1_2-19-15

    41/124

    Hydronic Accessories

    Viessmann Mixing ValvesViessmann Mixing Valve Motor, 120/1/60

    n for Viessmann 3- and 4-way mixing valves onlyn order one mixing valve per low-temperature heating circuitn including strap-on supply temperature sensor (NTC 10 kOhm)

    Maximum 2 Mixing Valves per single- or multiple-boiler application

    7509 472225.

    Order No.US$

    Power Supply Adaptorrequired for eachViessmann mixing valve motor

    n 120/1/60

    7134 560174.

    Order No.US$

    VITODENS 200-WMultiple Boiler Installations

    This trademark is registered with the U.S. Patent and Trademark Office. 39

    Circulation Pumps

    Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800UPS26-99FC120/1/60

    7248 585391.

    Order No.US$

    Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800UPS26-150FC120/1/60

    7441 596611.

    Order No.US$

    Multiple Boiler Low-Loss Distribution Manifold

    Accessories

    Connection Setto install a field supplied 90 elbow set

    n 4 x 4 ANSI flanges with welded on 4 NPT coupling

    7537 723727.

    Order No.US$

    Insulation

    Manifold Insulation 7537 7122-boiler

    668.

    7537 7133-boiler1,125.

    Order No.

    US$

    Low-Loss Header Insulation

    For use with 7537705160/80

    7537706200/120

    7537707250/150

    7537708300/200

    7537709400/200

    7537710450/250

    7537711500/300

    7537 714435.

    7537 715559.

    7537 716639.

    7537 717727.

    7537 718788.

    7537 719950.

    7537 7201,089

    Order No.US$

    Y-Piece Insulation 7537 722328.

    Order No.US$

  • 7/21/2019 Vi_PriceList1_2-19-15

    42/12440

    Hydronic Accessories

    Viessmann 3-Way Mixing Valves 7134 742

    308.

    17134 743

    328.

    17134 744

    368.

    17134 745

    413.

    27134 746

    506.

    DiaOrder No.US$

    Danfoss 3-Way Mixing Valvesn including flange setn includes actuator

    2ZK01698

    1,001.

    3ZK01699

    1,143.

    4ZK01700

    1,506.

    5ZK01701

    1,623.

    6ZK01702

    2,056.

    DiaOrder No.US$

    NeutralizationNeutralization System

    n to neutralize acidic condensaten includes pellets

    7441 823424.

    Order No.US$

    Sensors

    Room Temperature Sensor (wall mount, NTC 10 kOhm)for use with Vitotrol 300AOrder Room Temperature Sensor if Vitotrol 300A cannot be installed in acentralized location to measure room temperature.

    7438 537108.

    Order No.US$

    Remote Controls

    Vitotrol 200A(KM-BUS protocol)User interface to operate one heating circuit:

    n daytime temperature and operating programn with party and energy-saving buttonn display indication of outside temperature, room temperature andoperational settings

    n with room temperature sensor for room-dependent activation(for heating circuit with mixing valve only)

    If the Vitotrol 200A is to operate based upon room-dependent activation,ensure placement in a centralizedlocation.

    7438 363162.

    Order No.US$

    Vitotrol 300A(KM-BUS protocol)User interface to operate one, two or three heating circuits:

    n daytime temperature, set-back temperature, DHW temperature, operatingand holiday program, as well as party and energy-saving function

    n timer program for heating circuits, DHW production, and DHW recirculationpump

    n illuminated graphic display to show outdoor temperature, roomtemperature, operational settings together with descriptive texts

    n with room temperature sensor for room-dependent activation(for heating circuit with mixing valve only)

    If the Vitotrol 300A is to operate based upon room-dependent activation,ensure placement in a centralizedlocation.Order Room Temperature Sensor 7438537 if the Vitotrol 300 cannot be installedin a centralized location.

    7172 619272.

    Order No.US$

    VITODENS 200-WMultiple Boiler Installations

  • 7/21/2019 Vi_PriceList1_2-19-15

    43/124

    This trademark is registered with the U.S. Patent and Trademark Office. 41

    Boiler/Tank Packages

    Vitodens 200-W

    with Vitocell tanksVitocell 100

    CVA SeriesCVB Series

    Indirect-fired domestic hot water storage tanksteel construction, withCeraprotect two-coat enamel finish

    Vitocell 300

    EVI SeriesEVB Series

    Indirect-fired domestic hot water storage tankof high grade stainless steel

    This trademark is registered with the U.S. Patent and Trademark Office.

    Vitodens 200-W Vitocell 100 Vitocell 300

    B2HA/B2HB Series

    Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operationHeating input: 12 to 530 MBH

    3.5 to 155 kW

    For natural gas or liquid propane gas

  • 7/21/2019 Vi_PriceList1_2-19-15

    44/124

    Single Vitodens 200with Vitocell 300-V packages

    Package No Boiler Boiler Qty Tank Tank Qty Price

    B2HB010 Vitodens 200, B2HB-19 1 Vitocell 300, EVI- 53 1 5,679. US$

    B2HB011 Vitodens 200, B2HB-26 1 Vitocell 300, EVI- 53 1 5,858. US$

    B2HB012 Vitodens 200, B2HB-35 1 Vitocell 300, EVI- 53 1 6,065. US$

    B2HAC78 Vitodens 200, B2HA-45 1 Vitocell 300, EVI- 79 1 7,396. US$

    B2HAC79 Vitodens 200, B2HA-60 1 Vitocell 300, EVI- 79 1 8,153. US$

    B2HAC80 Vitodens 200, B2HA-80 1 Vitocell 300, EVI- 79 1 9,491. US$

    B2HAC81 Vitodens 200, B2HA-45 1 Vitocell 300, EVB- 79 1 8,183. US$

    B2HAC82 Vitodens 200, B2HA-60 1 Vitocell 300, EVB- 79 1 8,940. US$

    B2HAC83 Vitodens 200, B2HA-80 1 Vitocell 300, EVB- 79 1 10,279. US$

    B2HAC84 Vitodens 200, B2HA-80 1 Vitocell 300, EVI- 119 1 11,176. US$

    B2HAC85 Vitodens 200, B2HA-100 1 Vitocell 300, EVI- 119 1 12,483. US$

    B2HAC86 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 119 1 13,159. US$

    B2HAC87 Vitodens 200, B2HA-80 1 Vitocell 300, EVB- 119 1 11,194. US$

    B2HAC88 Vitodens 200, B2HA-100 1 Vitocell 300, EVB- 119 1 12,448. US$

    B2HAC89 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 119 1 13,443. US$

    B2HAC90 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 79 2 14,387. US$

    B2HAC91 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 119 2 17,385. US$

    B2HAC92 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 79 2 15,962. US$

    B2HAC93 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 119 2 17,792. US$

    B2HAC94 Vitodens 200, B2HA-150 1 Vitocell 300, EVI- 79 2 17,277. US$

    B2HAC95 Vitodens 200, B2HA-150 1 Vitocell 300, EVI- 119 2 20,366. US$

    B2HAC96 Vitodens 200, B2HA-150 1 Vitocell 300, EVB- 79 2 18,852. US$

    B2HAC97 Vitodens 200, B2HA-150 1 Vitocell 300, EVB- 119 2 20,682. US$

    Boiler/Tank Packages

    42

  • 7/21/2019 Vi_PriceList1_2-19-15

    45/124

    Single Vitodens 200with Vitocell 100-V packages

    Package No Boiler Boiler Qty Tank Tank Qty Price

    B2HB013 Vitodens 200, B2HB-19 1 Vitocell 100, CVA-42 1 4,718. US$

    B2HB014 Vitodens 200, B2HB-26 1 Vitocell 100, CVA-42 1 4,896. US$

    B2HB015 Vitodens 200, B2HB-35 1 Vitocell 100, CVA-42 1 5,103. US$

    B2HB016 Vitodens 200, B2HB-19 1 Vitocell 100, CVA-53 1 5,110. US$

    B2HB017 Vitodens 200, B2HB-26 1 Vitocell 100, CVA-53 1 5,289. US$

    B2HB018 Vitodens 200, B2HB-35 1 Vitocell 100, CVA-53 1 5,496. US$

    B2HAD04 Vitodens 200, B2HA-45 1 Vitocell 100, CVA-79 1 6,602. US$

    B2HAD05 Vitodens 200, B2HA-60 1 Vitocell 100, CVA-79 1 7,359. US$

    B2HAD06 Vitodens 200, B2HA-80 1 Vitocell 100, CVA-79 1 8,697. US$

    B2HAD07 Vitodens 200, B2HA-45 1 Vitocell 100, CVB-79 1 7,005. US$

    B2HAD08 Vitodens 200, B2HA-60 1 Vitocell 100, CVB-79 1 7,762. US$

    B2HAD09 Vitodens 200, B2HA-80 1 Vitocell 100, CVB-79 1 9,101. US$

    B2HAD10 Vitodens 200, B2HA-80 1 Vitocell 100, CVA-119 1 9,073. US$

    B2HAD11 Vitodens 200, B2HA-100 1 Vitocell 100, CVA-119 1 10,327. US$

    B2HAD12 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-119 1 11,321. US$

    B2HAD13 Vitodens 200, B2HA-80 1 Vitocell 100, CVB-119 1 10,104. US$

    B2HAD14 Vitodens 200, B2HA-100 1 Vitocell 100, CVB-119 1 11,358. US$

    B2HAD15 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-119 1 12,353. US$

    B2HAD16 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-79 2 12,798. US$

    B2HAD17 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-119 2 13,549. US$

    B2HAD18 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-79 2 13,606. US$

    B2HAD19 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-119 2 15,612. US$

    B2HAD20 Vitodens 200, B2HA-150 1 Vitocell 100, CVA-79 2 15,688. US$

    B2HAD21 Vitodens 200, B2HA-150 1 Vitocell 100, CVA-119 2 16,439. US$

    B2HAD22 Vitodens 200, B2HA-150 1 Vitocell 100, CVB-79 2 16,496. US$

    B2HAD23 Vitodens 200, B2HA-150 1 Vitocell 100, CVB-119 2 18,502. US$

    Boiler/Tank Packages

    This trademark is registered with the U.S. Patent and Trademark Office. 43

  • 7/21/2019 Vi_PriceList1_2-19-15

    46/12444

    NOTES

  • 7/21/2019 Vi_PriceList1_2-19-15

    47/124

    This trademark is registered with the U.S. Patent and Trademark Office. 45

    VITODENS 222-F

    Gas-fired, floor-standing, condensing DHW combi-boile12 to 125 MBH / 3.5 to 35 kW

    Vitodens 222-F

    B2TB Series

    Gas-Fired Floor-StandingCondensing DHW Combi-Boilerwith modulating MatriX-cylinder burnerand DHW stainless steel tankfor room air dependent operationor room air independent operationHeating input: 12 to 125MBH

    3.5 to 35kW

    For natural gas or liquid propane gas

    n Low cycle frequency, even with low heat demand, through optimizedpauses and wider modulation range of up to 1:6.5.

    n Durable and efficientthanks to the Inox-Radial heat exchanger.

    nMatriX gas burnerwith long service life thanks to stainless steel

    MatriX gauze resistant to high temperature loads.

    n Energy-saving, high efficiency circulation pump (DHW tank).

    n Lambda Pro Controlcombustion controller for all gas types saveson costs through an extension of the inspection interval to 3 years.

    n Universal connection setsfor individual installation flush with thewall.

    This trademark is registered with the U.S. Patent and Trademark Office.

  • 7/21/2019 Vi_PriceList1_2-19-15

    48/124

    Vitodens 222-F

    B2TB19

    B2TB35

    ModelNo.

    for SingleBoiler Installations only

    Vitodens 222-Fwith Vitotronic 200 HO1B

    Each Vitodens 222-F mustbe sold and shipped with aConnection Set

    B2TB0035,337.

    B2TB0045,646.

    Order No.US$

    Connection Setfor left/right connection

    7201 537328.

    Order No.US$

    Connection Setfor top connection

    7201 538

    328.

    Order No.

    US$

    Total List Price

    Input Range

    Output Range

    12-683.5-20

    10.9-643.2-19

    5,665.

    19-1255.5-37

    17.4-1175.1-34

    5,974.

    MBHkW

    MBHkW

    US$

    VITODENS 222-F

    f Boiler standard working pressure: 30 psig;For 45 psig, order optional PRV 9549 944, List Price $35..f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

    Standard Equipment:Wall-mount boiler with integrated 26 USG / 100 ltr DHW tank,Vitotronic 200 HO1B, Connection Set, and installation fittings.

    Technical Data

    DimensionsLength

    Width

    Height

    23595235/8600

    641625

    23595235/8600

    641625

    inchesmminchesmminchesmm

    Boiler Vent Connectionflue gas / fresh air 60/100 60/100 mm

    Boiler Pressure Relief Valve 30 30 psig

    DHW Pressure Relief Valve 150 150 psig

    DHW Storage Tank 26100

    26100

    USGltr

    Shipping Weight (incl. fittings)not including vent system

    311141

    311141

    lbskg

    46

  • 7/21/2019 Vi_PriceList1_2-19-15

    49/124

    VITODENS 222-F

    Controls and Accessories

    This trademark is registered with the U.S. Patent and Trademark Office. 47

    Accessories

    Communication

    LON Connecting Cable, 23ft / 7mfor data exchange between controls

    7143 49552.

    Order No.US$

    LON Extension Jackto extend LON Connecting Cable

    7143 49634.

    Order No.US$

    LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes

    7171 78476.

    Order No.US$

    LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end

    7143 49714.

    Order No.US$

    LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LON

    system BUS. For installation inside Vitodens 200-W.

    7179 113328.

    Order No.US$

    Expanded Functions

    Extension Module AM1wall-mounted extension module controls up to 2 of the following circulationpumps:

    n DHW recircula