Price List 2014-2015
nFloor-Standing BoilersnWall-Mount BoilersnDomestic Hot Water TanksnSystem TechnologynSolar SystemsnCommercial BoilersnBiomass Boilers
Effective 1-Sep-14; Revised 19-Feb-15
1
USA
-
7/21/2019 Vi_PriceList1_2-19-15
2/124
-
7/21/2019 Vi_PriceList1_2-19-15
3/124
Contents
3 Vitorond 100 Oil-Fired Heating Boilers91 to 245 MBH
Gas-Fired Condensing Boilers
12 to 530 MBH
Indirect-Fired DomesticHot Water Storage Tanks
Heating System Controls
Hydronic Heating Accessories
Solar Collectors
System Technology
Simulation Software
Sectionalcast iron boilers
91 to 245 MBH
45 Vitodens 222-F
Wall-mount boilers
Floor-standingboilers
37 to 118 MBH
12 to 530 MBH
12 to 125 MBH
53 Vitocrossal 200
Steel/stainlesssteel boilers
59 Vitocell 10061 Vitocell 300
DHW Pump Module and Electronic Anode
42 to 119 USG 42 to 119 USG
67 Vitotronic 200-H74 BMS Gateways75 Low-Loss Headers Transport
79 Vitosol84 Vitosol 100-F86 Vitosol 200-F88 Vitosol 200-T, SPE90 Vitosol 200-T, SP2A93 System Technology
100 ESOP NA 4.0
101 Vitorond 200
103 Vitorond 200
105 Vitocrossal 300
107 KOB Wood Fired Systems
PyrotPyrotec
Gas-Fired Condensing Boilers133 to 2245 MBH
133 to 2245 MBH
Solar Combi-Packagesplate collectors
Vacuum tubecollectors
PAGE
9 Vitodens 100-W
17 Vitodens 200-W
111 Terms and Conditions of Sale, Delivery and Payment
113 Venting Categories for Gas-Fired Boilers
114 Viessmann Warranties
115 Approval and Listing Overview
121 Viessmann North AmericaContact Information
Appendix
This trademark is registered with the U.S. Patent and Trademark Office. 1
Oil-/Gas-Fired Heating Boilers490 to 4387 MBH
Gas-Fired Condensing Boilers638 to 3361 MBH
Sectionalcast iron boilers
Steel/Stainless Steelboilers
490 to 1096 MBH
1255 to 4387 MBH
638 to 3361 MBH
Biomass Boilerwith Automatic Fuel Feed System512 to 4268 MBH
Biomass boilers 512 to 1843 MBH1330 to 4268 MBH
-
7/21/2019 Vi_PriceList1_2-19-15
4/1242
-
7/21/2019 Vi_PriceList1_2-19-15
5/124
VITOROND 100
Vitorond 100
VR1 Series
Oil-Fired Boilerfor hydronic heating systemsof cast iron sectional constructionHeating input: 91 to 245 MBH
27 to 72 kW
n Eutectoplex heat exchangerfor high operational reliability and along service life.
n Triple-pass heat exchanger design provides reduced emissions,efficient fuel utilization and low heating costs.
n Economical and environmentally friendly operation
n Problem-free cleaning access facilitated by a hinged (left orright), swing-open combustion chamber door providing easyaccess to all three heat exchanger passes from boiler front.
This trademark is registered with the U.S. Patent and Trademark Office.
Vitorond 100 with Beckett Burner andHydroLevel Control
Vitorond 100 with Beckett Burnerand Vitotronic 100 KW10B Control
3
Hot water heating boiler 91 to 245 MBH / 27 to 72 kW
-
7/21/2019 Vi_PriceList1_2-19-15
6/124
VITOROND 100
System Type Control Option
n 1 heating circuitwithout mixing valve
HydroLevelthermal reset boiler control
n 1 heating circuitwithout mixing valve
n 1 DHW production circuit
Vitotronic 100, KW10Bfor high temperature heating systems
n with indoor/outdoor system controln with domestic hot water production and pump outputn with boiler pump outputn with compiled fault output (dry contact)n with 0-10 VDC inputn with adjustable high limit and fixed high limitn with space heating circuit switchn with power indication, call for heat indication,and burner/FHL fault indication
n with the Viessmann quick-connect plug-in system
n 1 circuit without mixing valven 1 circuit with mixing valven 1 DHW production circuit
Vitotronic 200, KW2
for multiple temperature heating systemsIndoor/outdoor, digital boiler and heating system control
n with digital tracking of day and weekn with programmable time periods, heatingcurves, temperature setpoints and operating programs
n with DHW production management (sensor included)n with integrated diagnostic systemn with adjustable high limit and fixed high limitn with FHL test switchn with power indication and sensor/burner fault indicationn with the Viessmann quick-connect plug-in system
f Boiler standard working pressure: 30 psig; maximum working pressure: 45 psig.
For 45 psig, order optional pressure relief valve 9549 944,List Price $35..
An Order No. is supplied for each possible configuration, so all necessary components may easily be ordered together.
Standard Equipment of Boiler:
Boiler shell (insulation preinstalled up to size -33), combustion chamber insert, installation fittings c/w 30 psig pressure reliefvalve, drain valve, Tridicator, boiler control (above), burner wiring harness, burner (above) c/w correct oil nozzle
To order Vitotronic 100, KW10B separately 7834 238, List Price $848.-To order Vitotronic 200, KW2 separately Z001 230, List Price $1863.-To order Vitotronic 300, KW3 separately Z001 231, List Price $2133.-
OTS
OTS
OTS
n with wall mounting kitn with integrated low-water cut-off function
4
-
7/21/2019 Vi_PriceList1_2-19-15
7/124
VITOROND 100
ControlOption
BurnerOption
VR1-22 VR1-27 VR1-33 VR1-40 VR1-50 VR1-63 Model No.
Hydrolevel No Burner VR103191,741.
VR103201,952.
VR103212,105.
VR103222,438.
VR103232,760.
VR103243,091.
Order No.US$
Hydrolevel Beckett OilforChimney Venting
VR103072,409.
VR103082,620.
VR103092,773.
VR103103,106.
VR103113,399.
VR103123,730.
Order No.US$
Hydrolevel Beckett Oilfor Direct Venting
VR102953,484.
VR102963,695.
VR102973,848.
N/A N/A N/A Order No.US$
Hydrolevel Riello OilforChimney Venting
VR103132,638.
VR103142,849.
VR103153,020.
VR103163,353.
VR103173,675.
VR103184,235.
Order No.US$
Hydrolevel Riello Oilfor Direct Venting
VR103043,980.
VR103054,191.
VR103064,379.
N/A N/A N/A Order No.US$
Vitotronic 100,KW10B
Beckett OilforChimney Venting
VR102233,280.
VR102243,491.
VR102253,644.
VR102263,975.
VR102274,268.
VR102284,599.
Order No.US$
Vitotronic 100,KW10B
Beckett Oilfor Direct Venting
VR102354,355.
VR102364,566.
VR102374,719.
N/A N/A N/A Order No.US$
Vitotronic 100,KW10B
Riello OilforChimney Venting
VR102293,509.
VR102303,720.
VR102313,891.
VR102324,222.
VR102334,544.
VR102345,104.
Order No.US$
Vitotronic 100,KW10B
Riello Oilfor Direct Venting
VR102384851.
VR102395062.
VR102405250.
N/A N/A N/A Order No.US$
Vitotronic 200,
KW2
Beckett Oilfor
Chimney Venting
VR10151
4,295.
VR10152
4,506.
VR10153
4,659.
VR10154
4,990.
VR10155
5,283.
VR10156
5,614.
Order No.
US$
Vitotronic 200,KW2
Beckett Oilfor Direct Venting
VR101905370.
VR101915581.
VR101925734.
N/A N/A N/A Order No.US$
Vitotronic 200,KW2
Riello OilforChimney Venting
VR101754,524.
VR101764,735.
VR101774,906.
VR101785,237.
VR101795,559.
VR101806,119.
Order No.US$
Vitotronic 200,KW2
Riello OilforDirect Venting
VR102025,866.
VR102036,077.
VR102046,265.
N/A N/A N/A Order No.US$
Specifications
MBH Input
Output
91
80
105
92
140
122
161
140
196
172
245
215
MBH
Dimensions Boiler Length(incl. burner)
Boiler Width
Boiler Height
3897619500
33840
44111619500
33840
44111619500
33840
36914
221/4
565393/4
1010
371/2
956221/4
565393/4
1010
421/2
1081221/4
565393/4
1010
inchesmminchesmminchesmm
Boiler Water Content 9.235
11.644
11.644
12.748
16.161
19.373
USGltr
Boiler Vent Connection 5 6 inches
Weight(Shipping) Boiler package 442200
508230
508230
564256
694315
822373
lbskg
This trademark is registered with the U.S. Patent and Trademark Office. 5
-
7/21/2019 Vi_PriceList1_2-19-15
8/124
VITOROND 100Controls and Accessories
6
Controls
Multiple Boiler Applications
n 4 boilers max.n 2 heating circuitswith mixing valve max.
n DHW production
Vitocontrol-SCascade Control
n Digital outdoor reset boiler and heating system control.Master control for up to 4 boilers, controlling two heating circuitswith mixing valve and domestic hot water production
n Each boiler must be equipped with Vitotronic 100, KW10Bn LON-enabled for multiple boiler installations
7134 6324,148.
Order No.US$
Power Supply Adaptor 7134 560174.
Order No.US$
LON Communication Modulefor data exchange with Vitocontrol Cascadeor other LON-compatible supervision system.(order 1 unit per boiler)
7834 357436.
Order No.US$
LON Connection Terminalto convert standard LON cable of Vitocontrol-Sto 2-wire communication used in Vitotronic 100.(order 1 unit per Vitocontrol-S)
7134 631110.
Order No.US$
Lead-Lag Expansion Kit (single-stage boilers only)for load-dependent staging of a second boiler.First boiler must be equipped with either Vitotronic 200/300.Second boiler must be equipped with Vitotronic 100 KW10B.
7133 897611.
Order No.US$
Communication
Output Module (potential-free contact) for burnerstatus, burner failure, high boiler temperature, andexternal (LWCO) alarm via LON.(Order one per boiler; max.:4)
7134 562695.
Order No.US$
Switching Module-V to expand the capabilities of Vitotronic 200 and 300via:
n remote burner enable and disablen providing for additional heat demand (pool, spa, snowmelt, etc)n using with an external contact or Telephone Interface Module toremotely change heating/operating mode of the heating circuit
7133 387272.
Order No.US$
Telephone Interface Modulenecessary to operate heating system via telephone communication(Switching Module-V also required)
9543 4211,004.
Order No.US$
Expandability
KM-BUS Expansion Moduleto connect up to 9 devices to the single KM-BUS connectionof the boiler control(Vitotrol, Switching Module-V, etc.)
7133 393108.
Order No.US$
Vitotronic Retrofit Housing for RN (SS) 7133 923344.-
Order No.US$
Vitotronic Retrofit Housing for RN (TS) 7133 923483.-
Order No.US$
Vitotronic Retrofit Housing for RS/AR 7133 925250.-
Order No.US$
Vitotronic Retrofit Housing for VBC/VNE/BEA 7133 922214.-
Order No.US$
-
7/21/2019 Vi_PriceList1_2-19-15
9/124
This trademark is registered with the U.S. Patent and Trademark Office. 7
VITOROND 100Controls and Accessories
Accessories
Vitorond 100
Mixing Valve Actuator7542 257
225.OrderNo.US$
VR1-22 VR1-27 VR1-33 VR1-40 VR1-50 VR1-63 Model No.
Boiler Stand for Vitorond 1009" / 250 mm height
7133 073162.
7133 074162.
7133 075162.
7133 076174.
Order No.US$
DHW Pump Modulefor Vitorond 100 with Hydrolevel
control
9543 430559.
Order No.US$
Wiring Harnessto integrate Tjernlund CombustionAir In-ForcerTM(field supplied) withVitotronic control
7133 92187.
Order No.US$
Carrying Handles 7189 602Net price 78.
N/A Order No.US$
Two-Wheel Truckn Special two-wheel truck forViessmann boilers and domestichot water tanks
9521 645Net price 1,413.
Order No.US$
Transport Paneln For use with ViessmannTwo-Wheel Truck (above)
7198 575Net price 102. N/A Order No.US$
Remote Controls
Vitotrol 200 Remote Control for a single heating circuit to program:n daytime temperature and operating program;n with party and energy-saving buttonn with room temperature sensor for room-dependent activationn (for heating circuit with mixing valve only)If the Vitotrol 200 is to operate based upon room-dependent activation, ensure placement in a centralized location.
7438 363162.
Order No.US$
Vitotrol 300A Remote Control for a single heating circuit to program:n daytime and nighttime temperature, DHW temperature, operating and holiday program,party and energy-saving features
n switching times for heating circuit, DHW tank and recirculation pumpn with illuminated display and textual promptsn with room temperature sensor for room-dependent activation (for heating circuit with mixing valve only)
If the Vitotrol 300 is to operate based upon room-dependent activation, ensure placement in a centralized location.
7172 619272.
Order No.US$
Room Temperature Sensorif the Vitotrol cannot be installed in a centralized location(must be sold with Remote Control RS, Vitotrol 200, or Vitotrol 300)
7133 379121.
Order No.US$
Mixing Valve Controller Accessory Kitto control a single heating circuit with one mixing valve; includes:
n mixing valve motor to operate /4to 2/2 Viessmann mixing valvesn supply temperature sensor
-
7/21/2019 Vi_PriceList1_2-19-15
10/1248
NOTES
-
7/21/2019 Vi_PriceList1_2-19-15
11/124
VITODENS 100-WGas-fired, stainless steel condensing boile
37 to 118 MBH / 11 to 35 kW
n Lasting Performancewith industry leading Viessmann madeSA240 316 Ti stainless steel Inox-Radial heat exchanger constructedto CSA B51 and ASME Section IV.
n Low-Emission Combustionwith Viessmann made stainlesssteel MatriX cylinder burner for natural gas or propane. Factorycalibrated.
n Versatile On-Board Boiler Control interfaces with most externalcontrols. Now with integrated OpenTherm and optional 0-10Vcommunication ability. Outdoor temperature sensor standard.
n Greater Venting Flexibilitywith increased vent length(up to 200 ft. / 61m) and multiple venting options:- Horizontal or vertical sealed combustion coaxial venting.- Horizontal, vertical or hybrid sealed combustion double-pipe
venting.- Horizontal or vertical single-wall venting.
n Altitude Levels of up to 10000 ft. / 3000 m.n Easy Installation, Service and Maintenancewith all pipe connectionslocated at the bottom and serviceable components easily accessiblefrom the front.
n Limited Lifetime Warrantyin residential applications.
Vitodens 100-W
WB1B Series
Gas-/Propane-Fired Wall-Mounted Condensing Boilerwith modulating stainless steel MatriX cylinder burnerstainless steel Inox-Radial heat exchangerfor room air dependent operationor room air independent operation.
CombiPLUSKit provides reliable on demand hot water without aDHW tank.Heating input: 37 to 118 MBH
11 to 35 kW
CombiPLUSKit
This trademark is registered with the U.S. Patent and Trademark Office. 9
-
7/21/2019 Vi_PriceList1_2-19-15
12/124
VITODENS 100-W
Vitodens 100-W
WB1B26
WB1B35
Model No.
Vitodens 100-WWB1B500 WB1B501 Order No.
Input Range 37-9111-27
37-11811-35
MBHkW
Output Range34-8310-24
34-10810-32
MBHkW
List Price 2,884. 3,193. US$
CombiPLUS Kitto provide reliable on demand hotwater without a DHW tankList Price
7459 305
515.
Order No.
US$
Specifications WB1B26
WB1B35
Dimensionsexcluding LengthCombiPLUS Kit Width
Height
14/8360
15/4400
28/2725
14/8360
15/4400
28/2725
inchesmminchesmminchesmm
Boiler Vent Connectionflue gas / fresh air
2/8/ 460/100
2/8/ 460/100
inchesmm
Shipping Weightboiler (incl. fittings)excluding vent system
9543
9543
lbskg
CombiPLUS Kit 31
14
lbs
kgCombiPLUS Kit
DHW Supply Temperature 14060
FC
Continuous draw rate with DCW temp. of 56F / 13C
99374
147556
USG/hL/h
Continuous draw rate at delta t= 63 F / 35K
156589
216800
USG/hL/h
f Boiler standard working pressure: 30 psig; maximum: 45 psig. For 45 psig, order optional PRV 9549 944, List Price $35..f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
Boiler Standard Equipment:Wall-mount boiler and installation fittings c/w 30 psig
pressure relief valve, pressure gage, gas shut-offvalve, two fill/drain valves, all mounting hardware,supplied analog temperature gaugeoutdoor temperature sensor, and LP conversion kit.
CombiPLUS Standard Equipment:Plate type heat exchanger,built-in diverting valve,built-in Grundfos 3-speed pump,built-in pressure by-pass valve,built-in water hammer arrester,built-in flow sensor,built-in temperature sensor,supplied with 150 psig pressure relief valve.
CombiPLUS Kit only for use with boilers
WB1B500, WB1B501 above!
10
f The products above utilize the OpenTherm communication protocol,
and are therefore onlysuitable for use with Vitodens 100-W.
-
7/21/2019 Vi_PriceList1_2-19-15
13/124
This trademark is registered with the U.S. Patent and Trademark Office. 11
VITODENS 100-W
Accessories
WB1B26
WB1B35
Model No.
Single Boilers
VersatronikComo OTdigital room temperature control featuring:
n comfort button to adjust room temperaturen 7-day timer with 3 settings per dayn party mode and energy-saving moden 99-day holiday mode, and more.
n dimensions: W 5/4 / 146mmH 4 / 102mmD 1/2 / 38mm
7416 056322.
Order No.US$
Versatronik10.WB1DHW pump module to manage domestic hot water production for Vitodens 100-Wwith oneindirect fired storage tank
n dimensions: W 6/2 / 165mmH 8/4 / 210mm
D 2/2 / 64mm
7416 058538.
Order No.US$
Multiple Boilers
Versatronik200to control up to 8 Vitodens 100-W featuring:
n load-dependent boiler activation and modulation via OpenThermcommunicationn menu-driven LCD displayn indoor/outdoor control operationn control of 2 mixing valve actuatorsn control of 2 circulation pumpsn domestic hot water production
n
includes 2 x CoCo OT adaptors 7416 060 (for boilers 1 and 2)n dimensions: W 9/2 / 241mm
H 8 / 210mm
D 2 / 64mm
7416 0591,642.
Order No.US$
CoCo OT AdaptorOpenThermadaptor for use with Versatronik200 only(order 1 unit for each of boilers 3 through 8)
7416 060284.
Order No.US$
Mixing Valve Adaptor, 24V or 120Vto operate up to 2 mixing valve actuators. Important: both mixing valve actuators mustbe either24V or 120V - not mixed.Includes 1 strap-on sensor, and 1 immersion sensor.(max. 1 unit per Versatronik200)Viessmann mixing valve actuator: 7542 257
7416 06185.
Order No.US$
Versatronik
Lago OT for use with Versatronik
200 onlyn with display for weather-, space-, or time-oriented control of the room temperature
n dimensions: W 3 / 83mm
H 3 / 83mm
D 1/2 / 38mm
7416 062284. Order No.US$
Input Module 0-10V OTOpenThermTMinput module, to enable a boiler reset modulecontroller to communicate with the Vitodens 100-W via0-10V (DC) modulating input signal (order 1 until per boiler).
7249 069256.
Order No.US$
f The products above utilize the OpenTherm communication protocol, and are therefore onlysuitable for use with Vitodens 100-W.1 Aquastat may be ordered from Viessmann 9560 985, List Price $142..
Controls and Accessories
(max. 1 unit per boiler; compatible with
outdoor temperature sensor supplied
with boiler)
(max. 1 unit per boiler/tank combination;aquastat 1or set-point control must be
field supplied)
(max. 2 units per Versatronik200)
-
7/21/2019 Vi_PriceList1_2-19-15
14/124
VITODENS 100-W
1 Separate circulation pump required for each boiler. Select based upon system pressure drop and flow rate requirement
See technical data manual. Many other circulation pumps available please inquire.
12
Controls and Accessories
Vitodens 100-W
Model No.
Accessories
Circulation Pump 1
Boiler delta TGrundfos 3-speed, flangedhousing circulation pump, 115V
Flange Set, 1/4(Others available, please inquire)
9560 86040F
UPS15-58FC225.
9544 42531.
Order No.
ModelUS$
Order No.US$
Low-Loss Headers 2
to decouple high flow rate systems from the boiler loop.
n Model 80/60 Low-Loss Headerwith insulationMax. flow rate 19.5 USGPM / 4.4 m3/hr
7498 529290.
Order No.US$
n Model 120/80 Low-Loss Headerwith insulationMax. flow rate 35 USGPM / 8 m3/hr
7498 530435.
Order No.US$
Neutralization Unitwith granular neutralization pellets
7134 231368.
Order No.US$
Neutralization Pelletsfor replacement purposes(2 x 2.9lbs / 1.3kg)
9524 67076.
Order No.US$
Service Tool Setfor Vitodens boilers
Service Kitfor Vitodens boilers models (WB1A, WB1B, WB2A, WB2B)
9537 070Net Price 121.
7522 9852,240.
Order No.US$
Order No.US$
2
For Low-Loss Header sizing, please see Technical Data Manual.
-
7/21/2019 Vi_PriceList1_2-19-15
15/124
This trademark is registered with the U.S. Patent and Trademark Office. 13
1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.Side wall venting installation mustinclude Viessmann Protective Screen!
2 Order 1Mounting Clip for eachstraight length of vent pipe installed.f Always follow the installation instructions of the vent manufacturer and of Viessmann.
VITODENS 100-WCoaxial PP(s) Vent System
Vent System 1 Vent System Diameter
60/100 80/125 100/150 Diameter
Horizontally Vented Maximum Equivalent
Length (EqL)
82 / 25
ft / m
98 / 30
ft / m
118 / 36
ft / m
ft. / m
Room AirIndependent Operation
Basic Horizontal Vent KitVenting pieces can be orderedindividually, or as a convenientkit using the Order No. to theright; Basic Vent Kit includesoneof each of the itemsnumbered to ,
and twoMounting Clips .
7424 119413.
7424 120460.
7424 121817.
Order No.US$
Boiler Vent Pipe Adaptor60/100
included with boiler
Adaptor, coaxial60/100 to 80/125not shown
Adaptor, coaxial60/100 to 100/150not shown
N/A
N/A
7424 112100.
N/A
N/A
7424 113162.
Order No.US$
Order No.US$
90 ElbowEqL = 1.6ft. / 0.5m
7424 09467.
7424 095100.
7424 096144.
Order No.US$
Straight Pipe 2
3.3ft. / 1m7424 091
76.7424 092
100.7424 093
121.Order No.US$
Vent Termination2.6ft. / 0.8m
7424 100144.
7424 101162.
7424 102174.
Order No.US$
Protective Screen1 7160 61677.
Order No.US$
Mounting Clip 2 (each) 7424 10916.10
7424 11020.
7424 11126.
Order No.US$
Other Available Vent Piecesnot shown in illustration above
Sliding Coupling1.25ft. / 0.4m
7424 10667.
7424 10776.
7424 10887.
Order No.US$
Straight Pipe 2
1.6ft. / 0.5m7424 088
52.7424 089
67.7424 090
100.Order No.US$
45Elbow (Set of 2)EqL = 1.0ft. / 0.3m
7424 097121.
7424 098135.
7424 099191.
Order No.US$
-
7/21/2019 Vi_PriceList1_2-19-15
16/124
1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.2 Order 1Mounting Clip for eachstraight length of vent pipe installed.
f Always follow the installation instructions of the vent manufacturer and of Viessmann.
Vent System 1 Vent System Diameter
60/100 80/125 100/150 Diameter
Vertically Vented Maximum Equivalent
Length (EqL)
82 / 25
ft / m
98 / 30
ft / m
118 / 36
ft / m
ft. / m
Room AirIndependent Operation
Boiler Vent Pipe Adaptor60/100
included with boiler
Adaptor, coaxial60/100 to 80/125not shown
Adaptor, coaxial60/100 to 100/150not shown
N/A
N/A
7424 112100.
N/A
N/A
7424 113162.
Order No.US$
Order No.US$
90 ElbowEqL = 1.6ft. / 0.5m
7424 09467.
7424 095100.
7424 096144.
Order No.US$
Mounting Clip 2 (each) 7424 10916.10
7424 11020.
7424 11126.
Order No.US$
Sliding Coupling1.25ft. / 0.4m
7424 10667.
7424 10776.
7424 10887.
Order No.US$
Straight Pipe 2
1.6ft. / 0.5m
Straight Pipe 2
3.3ft. / 1m
7424 088
52.or
7424 09176.
7424 089
67.or
7424 092100.
7424 090
100.or
7424 093121.
Order No.
US$
Order No.US$
45Elbow (Set of 2)EqL = 1ft. / 0.3m
7424 097121.
7424 098135.
7424 099191.
Order No.US$
Vent Termination3.9ft. / 1.2m
7424 103256.
7424 104350.
7424 105435.
Order No.US$
Roof Flashingand Storm Collar(B-Vent material or better)
fieldsupplied
B
A
Flue Gas Outlet
Combustion Air Intake
VITODENS 100-WCoaxial PP(s) Vent System
14
-
7/21/2019 Vi_PriceList1_2-19-15
17/124
This trademark is registered with the U.S. Patent and Trademark Office. 15
VITODENS 100-WVent Systems
Alternative Vent Systems
Boiler Flue Gas Connection
60 80 100 Diameter
Coaxial Venting 1 see page 14 60/100 80/125 100/150
direct-connect venting- no special adaptors required
Protective Screen(for side wall installations only)
7160 61677.
Order NoUS$
Rigid and Flexible PP(s) Venting 1 60 80 100 Diameter
for Combustion Air Intake 4
(only if installing ABS, CPVC orPVC piping for combustion air
intake, please order one CPVC
Adaptor per boiler)
Adaptor, CPVC60mm to 2
Adaptor2 to 3 or 3 to 4
7134 7697.90
7134 7697.90
fieldsupplied
7134 7697.90
fieldsupplied
Order NoUS$
Order NoUS$
CPVC Venting 2 2 3 4 Diameter
for Combustion Air Intake 4and for Flue Gas Outlet
Adaptor, CPVC60mm to 2
Adaptor2 to 3 or 3 to 4
2 x7134 769
7.90
2 x7134 769
7.90
fieldsupplied
2 x7134 769
7.90
fieldsupplied
QtyOrder NoUS$
Order NoUS$
Stainless Steel Venting 3 3 4 Diameter
for Combustion Air Intake 4 Adaptor, CPVC60mm to 2
Adaptor2 to 3 or 3 to 4
7134 7697.90
fieldsupplied
7134 7697.90
fieldsupplied
Order NoUS$
Order NoUS$
for Flue Gas Outlet PP(s) Adaptorfor stainless steel60mm to 80mm required
fieldsupplied
fieldsupplied
Order NoUS$
1 Coaxial and PP(s) vent material mustbe ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.2 CPVC vent material mustbe ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.3 Stainless steel vent material mustbe ULC/UL listed for Category IV boilers. Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.4 Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.
f Always follow the installation instructions of the vent manufacturer and of Viessmann.
-
7/21/2019 Vi_PriceList1_2-19-15
18/12416
NOTES
-
7/21/2019 Vi_PriceList1_2-19-15
19/124
VITODENS 200-WGas-fired, stainless steel condensing boiler
12 to 530 MBH / 3.5 to 155 kW
Vitodens 200-W
B2HA/B2HB Series
Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operationHeating input: 12 to 530 MBH
3.5 to 155kW
For natural gas or liquid propane gas
n Lasting Performance with industry-leading Viessmannmade SA240 316 Ti stainless steel Inox-Radial heatexchanger constructed to CSA B51 and ASME Section IV.
n Fast Installation and Reduced Maintenancewith LambdaPro, industry-first intelligent combustion management
system: Adjusts automatically to gas type and quality.No fuel conversion kit required.
n Expanded Application Rangewith increased capacity upto 530 MBH (155 kW). Multi-boiler installation up to4240 MBH (1240 kW) with up to 8 boilers(models B2HA 45 - 150).
n Extremely Quiet Operation; quieter than most refrigerators.
This trademark is registered with the U.S. Patent and Trademark Office. 17
-
7/21/2019 Vi_PriceList1_2-19-15
20/124
VITODENS 200-W
Vitodens 200-W
B2HB19
B2HB26
B2HB35
B2HA45
B2HA60
B2HA80
B2HA100
B2HA112
B2HA150
ModelNo.
Single or MultipleBoiler Installations
Vitodens 200-WwithVitotronic 200 HO1B
B2HB007 B2HB008 B2HB009 B2HAA90 B2HAA91 B2HAA92 B2HAA93 B2HAA94 B2HAA95 Order No.
List Price
InputRange
OutputRange
NG / LP
12-683.5-20
10.9-643.2-19
3,769.
19-945.5-27
17.4-885-26
3,957.
19-1255.5-37
17.4-1175-34
4,175.
60-16017-47
55-14611-43
4,999.
60-21217-62
55-19411-57
5,796.
104-28530-83
95-26028-76
7,205.
104-35230-103
98-33329-96
8,525.
113-39933-117
103-37530-110
9,572.
113-53033-155
103-49530-145
12,614.
MBHkW
MBHkW
US$
f Boiler standard working pressure: 30 psig up to B2HA 100 80 psig for B2HA 112/150;
For 30 psig, order optional PRV 9542 940, List Price $20.For 45 psig, order optional PRV 9549 944, List Price $35..For 60 psig, order optional PRV 9560 183, List Price $35..(sizes B2HA 45 and up only)f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
Standard Equipment:Wall-mount boiler, Vitotronic 200 HO1B, and installation fittings c/w 30 psig pressure relief valve, outdoor temperature sensor,DHW Sensor, LLH Sensor and Double Pipe Adaptor (for B2HA 45-150) gas shut-off valve, two fill/drain valves, and mounting hardware.
Technical Data
Dimensions153/4
400173/4
45041
1040
153/4
400173/4
45041
1040
153/4
400173/4
45041
1040
15380
19480
405/8
1031
15380
19480
405/8
1031
21530
19480
431/21105
21530
19480
431/21105
27698
235/8
600441/2
1128
27698
235/8
600441/2
1128
inchesmminchesmminchesmm
Boiler VentConnectionflue gas / fresh air
60/100 60/100 60/100 80/125 80/125 110/150 110/150 110/150 110/150 mm
Standard PressureRelief Valve
30 30 30 30 30 30 30 80 80 psig
Shipping Weight(incl. fittings)not including
vent system
11050
11050
11050
15572
15572
19488
19488
298135
298135
lbskg
Length
Width
Height
18
-
7/21/2019 Vi_PriceList1_2-19-15
21/124
VITODENS 200-W
This trademark is registered with the U.S. Patent and Trademark Office. 19
Vitodens 200-W
B2HB19
B2HB26
B2HB35
B2HA45
B2HA60
B2HA80
B2HA100
B2HA112
B2HA150
ModelNo.
Single BoilerInstallationwith Floor Stand
Vitodens 200-Wwith Vitotronic 200 HO1B
Input Range
Output Range
List Price NG / LP
B2HB004
12-683.5-20
10.9-643.2-19
3,948.
B2HB005
19-945.5-27
17.4-885-26
4,136.
B2HB006
19-1255.5-37
17.4-1175-34
4,354.
B2HAA99
60-16017-47
55-14611-43
5,178.
B2HAB00
60-21217-62
55-19411-57
5,975.
B2HAB01
104-28530-83
95-26028-76
7,384.
B2HAB02
104-35230-103
98-33329-96
8,704.
B2HAB03
113-39933-117
103-37530-110
9,773.
B2HAB04
113-53033-155
103-49530-145
12,815.
Order No.
MBHkW
MBHkW
US$
Boiler Standfor free-standinginstallationof a single boilerwithin themechanical room
7537 684(Applies to B2HB 19-35 and B2HA 45-100)
7502 558(Appliesto B2HA112-150)
Order No.
f Boiler standard working pressure: 30 psig up to B2HA 100 80 psig for B2HA 112/150;
For 30 psig, order optional PRV 9542 940, List Price $20.
For 45 psig, order optional PRV 9549 944, List Price $35..For 60 psig, order optional PRV 9560 183, List Price $35..(sizes B2HA 45 and up only)f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
-
7/21/2019 Vi_PriceList1_2-19-15
22/124
VITODENS 200-WAccessories
20
Accessories
Solar DHW Production and Supplemental Heating
Solar Module SM1Wall-mounted extension module with electronic differential control for dual-coil DHW production and to supplement space heating using solar collectorswhen used with oil/gas-fired heating boilers.
n operation and display via boiler controln management of two tank systems from one collector fieldn second electronic differential control capabilityn thermostat function for supplemental heating or use of surplus heatn variable speed pump controller for solar circuit pump via pulse-widthcontrol, or for solar circuit pump with PWM-input (mfg Grundfos)
n includes one tank sensor and one collector sensorn 120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plugn to be used instead of an SCU Solar Controller
7533 427466.
Order No.US$
Order immersion sensor 7438 702 if the following features are required:n for circulation management in systems with 2 storage tanksn for return flow management between boiler and hot water buffer tankn to supply heat to additional accessories
7438 70287.
Order No.US$
Communication
Vitogate 300, BN/MB Seriesconfigured as compact wall-mount unit-dimensions W 6 H 8 D 8
-120V, 60Hz, 1A, with 6.5 cord and 120V pkg
7559 7061,380.-
Order No.US$
LON Connecting Cable, 23ft / 7mfor data exchange between controls
7143 49552.
Order No.US$
LON Extension Jackto extend LON Connecting Cable
7143 49634.
Order No.US$
LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes
7171 78476.
Order No.US$
LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end
7143 49714.
Order No.US$
LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LONsystem BUS. For installation inside Vitodens 200-W.
7179 113328.
Order No.US$
Expanded Functions
Extension Module AM1wall-mounted extension module controls up to 2 of the following circulationpumps:
n DHW recirculation pumpn DHW production pumpn heating circuit pump for the circuit without a mixing valven 120V, 60Hz, 4A in CSA housing, with 6.5 / 2m cord and 120V plug
7533 425334.
Order No.US$
Each boiler must be equipped with 1X 7179 113 LON Communication Module.
-
7/21/2019 Vi_PriceList1_2-19-15
23/124
This trademark is registered with the U.S. Patent and Trademark Office. 21
VITODENS 200-WAccessories
Accessories
B2HB19
B2HB26
B2HB35
B2HA45
B2HA60
B2HA80
B2HA100
B2HA112
B2HA150
ModelNo.
Heating Circuit
Circulation Pump 1
Boiler delta TGrundfos 3-speed,flangedhousing circulationpump, 115V
7248 58540F
UPS 26-99FC391.
Order No
ModelUS$
Flange Set, 1(Others available,please inquire)
31. For all sizes9544 425
Order NoUS$
Low-Loss Headerwith Insulationto decouplehigh flow ratesystems fromthe boiler loop
80/60
19.5 USGPM4.4 m3/hr
7498 529290.
120/80
35 USGPM8 m3/hr
7498 530435.
Model
Order NoUS$
LLH Temperature Sensor(Immersion) to measure thetemperature inside a low-loss
header
7179 488121.
included with boiler
Order NoUS$
Neutralization Systemn to neutralize acidic
condensaten includes pellets
7134 231368.
7134 232413.
7441 823424.
Order NoUS$
Neutralization Granulate 9524 6705.7 lbs / 2.6 kg
76.
9521 70218 lbs / 8 kg
89.
Order No
US$
1 Separate circulation pump required for each boiler.Select based upon system pressure drop and flow rate requirement - see Vitodens Technical Data Manual.Many other circulation pumps available - please inquire.
Max. Flow
956086040F
UPS 15-58FC225.
7441 59640F
UPS 26-150FC611.-
-
7/21/2019 Vi_PriceList1_2-19-15
24/12422
VITODENS 200-WAccessories
Accessories
Low-Temperature Heating Circuits
Mixing Valve Extension Kit consisting of:
Mixing Valve Module(KM-BUS participant, wall mount)n including supply temperature sensor (strap-on)n plugs for circulation pump and mixing valve motorn KM-BUS cablen 120V, 60Hz, 2A in CSA housing, with 6.5 / 2m cord and 120V plug
ZK01105644.
Order No.US$
Mixing Valve Motor, 120/1/60n for Viessmann 3- and 4-way mixing valves onlyn including strap-on supply temperature sensor (NTC 10 kOhm)
Maximum 2 Mixing Valve Extensions per Vitodens boiler in single boilerapplications
Mixing Valves
Viessmann 3-Way Mixing Valves /47134 742
308.
17134 743
328.
1/47134 744
368.
1/27134 745
413.
27134 746
506.
DiaOrder No.US$
Sensors
Room Temperature Sensor (wall mount, NTC 10 kOhm)for use with Vitotrol 300A
Order Room Temperature Sensor if Vitotrol 300A cannot be installedin a centralized location to measure room temperature.
7438 537108.
Order No.US$
DHW Temperature Sensorto measure the temperature inside a domestic hot water storage tank
Includedwith boiler
7179 114121.
Order No.US$
-
7/21/2019 Vi_PriceList1_2-19-15
25/124
-
7/21/2019 Vi_PriceList1_2-19-15
26/124
-
7/21/2019 Vi_PriceList1_2-19-15
27/124
This trademark is registered with the U.S. Patent and Trademark Office. 25
VITODENS 200-WCoaxial PP(s) Vent System
1 PP(s) coaxial vent material mustbe ULC S-636 certified for Category IV boilers. Do notmix non-ULC S-636 with ULC S-636 venting.2 Order 1Mounting Clip for eachstraight length of vent pipe installed.
f Always follow the installation instructions of the vent manufacturer and of Viessmann.
Room AirIndependent Operation
Important!As a starting point,please pay attention toboiler vent connection sizeshown above
Boiler Vent Pipe Adaptor included with boiler
Order No.
US$ Flue Transition
110/150 to 100/150 only
not shown - requiredB2HA 80...150
N/A N/A 7424 11584.
Adaptor, coaxial60/100 to 80/125not shown - only for B2HB 19/26/35
Adaptor, coaxial60/100 to 100/150not shown - only for B2HB 19/26/35
Adaptor, coaxial80/125 to 100/150not shown - only for B2HA 45/60
N/A
N/A
N/A
7424 112100.
N/A
N/A
N/A
7424 113162.
7424 114121.
Order No.
US$
Order No.
US$
Order No.
US$
90 ElbowEqL = 1.6ft. / 0.5m
7424 09467.
7424 095100.
7424 096144.
Order No.
US$
Mounting Clip 2 (each) 7424 10916.10
7424 11020.
7424 11126
Order No.
US$
Sliding Coupling1.25ft. / 0.4m
7424 10667.
7424 10776.
7424 10887.
Order No.
US$
Straight Pipe2
1.6ft. / 0.5m
Straight Pipe 2
3.3ft. / 1m
7424 08852.
or7424 091
76.
7424 08967.
or7424 092
100.
7424 090100.
or7424 093
121.
Order No.
US$
Order No.
US$
45 Elbow (Set of 2)EqL = 1.0ft. / 0.3m
7424 097121.
7424 098135.
7424 099191.
Order No.
US$
Vent Termination3.9ft. / 1.2m 7424 103256. 7424 104350. 7424 105435.
Order No.US$
Roof Flashingand Storm Collar(B-Vent material or better)
fieldsupplied
Flue Gas Outlet
Combustion Air Intake
Vent SystemDiameter Vertically Vented Maximum Equivalent Length (EqL)
B2HB
19
B2HB
26
B2HB
35
B2HA
45
B2HA
60
B2HA
80
B2HA
100
B2HA
112
B2HA
150
Model
No
60/100 33 ft/10 m
33 ft/10 m
33 ft/10 m
N/A N/A N/A N/A N/A N/A
80/125 40 ft/12 m
40 ft/12 m
40 ft/12 m
33 ft/10 m
20 ft/6 m
N/A N/A N/A N/A
100/150 50 ft/15 m
50 ft/15 m
50 ft/15 m
43 ft/13 m
30 ft/9 m
50 ft/15 m
50 ft/15 m
26 ft/8 m
16 ft/5 m
B B
A A
110
10
10
12
12
11
6
6
6
6
6
6
8
8
9 9
9
9
9
2
2
2
B
A
1
11
-
7/21/2019 Vi_PriceList1_2-19-15
28/12426
VITODENS 200-WAlternative Vent Systems
Alternative Vent Systems
Boiler Flue Gas Connection
60 80 100 Diameter
Coaxial Venting 1 See previous 2 pages 60/100 80/125 100/150
Rigid and Flexible PP(s) Venting 1 60 80 100 Diameter
B2HA/B2HB19 to 150 for Combustion Air Intake 4
If installing ABS, CPVC or PVCpiping for combustion airintake, please order oneCPVCAdaptor per boiler
60>27134 769
7.90
80>37134 770
17.10
110>47134 771
26.
Size
Order No.US$
B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor80/125 to 80/80
N/A 7189 822100.
N/A Order No.US$
B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor110/150 to 110/110
N/A N/A 7373 253162.
Order No.
US$
Starter Adaptor 110/100 N/A N/A fieldsupplied
Order No.
US$
CPVC Venting 2 2 3 4 Diameter
B2HB 19 to 35 for Combustion Air Intake 4and for Flue Gas Outlet
Adaptor, CPVC60mm to 2
2 x7134 769
7.90
2 x7134 769
7.90
2 x7134 769
7.90
Qty
Order No.
US$
B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor80/125 to 80/80
N/A 7189 822100.
7189 822100.
Order No.
US$
Adaptor, CPVC80mm to 3
N/A 2 x
7134 77017.10
2 x
7134 77017.10
Qty
Order No.US$
B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor110/150 to 110/110
N/A N/A 7373 253162.
Order No.
US$
Adaptor, CPVC110mm to 4
2 x7134 771
26.
Qty
Order No.
US$
Stainless Steel Venting 3 3 4 Diameter
B2HB 19 to 35 for Combustion Air Intake 4 Adaptor, CPVC60mm to 2
N/A 7134 7697.90
7134 7697.90
Order No.
US$
for Flue Gas Outlet Starter Adaptor, SS2/3 or 2/4
N/A fieldsupplied
fieldsupplied
Order No.
US$
B2HA 45 to 60 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor80/125 to 80/80
N/A 7189 822100.
N/A Order No.US$
B2HA 80 to 150 for Combustion Air Intake 4and for Flue Gas Outlet
Double-Pipe Adaptor110/150 to 110/110
N/A N/A 7373 253162.
Order No.
US$
Starter Adaptor, PPs80/3 or 110/4
N/A fieldsupplied
fieldsupplied
Order No.
US$
1 Coaxial and PP(s) vent material mustbe ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.2 CPVC vent material mustbe ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.3 Stainless steel vent material mustbe ULC/UL listed for Category IV boilers. Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.4 Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.
f Always follow the installation instructions of the vent manufacturer and of Viessmann.
-
7/21/2019 Vi_PriceList1_2-19-15
29/124
VITODENS 200-WGas-fired, stainless steel condensing boile
320 to 4240 MBH / 94 to 1240 kW
Vitodens 200-W
B2HA Series, multiple boiler
Gas-/Propane-Fired Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operation
For natural gas or propane
n Viessmann Cascade Control for up to 8 boilers with heating input of320 MBH to 4240 MBH
n Lasting Performance with industry-leading Viessmannmade SA240 316 Ti stainless steel Inox-Radial heatexchanger constructed to CSA B51 and ASME Section IV.
n Low Emission Combustion with Viessmann made stainless steel
MatriX cylinder burner. Factory calibrated.n Powerful and User-Friendly Viessmann Vitotronicon-boardmulti-function outdoor reset boiler and system control for multi-temperature space and DHW heating.
n Fast Installation and Reduced Maintenancewith LambdaPro, industry-first intelligent combustion managementsystem: Adjusts automatically to gas type and quality.No fuel conversion kit required.
n Extremely Quiet Operation; quieter than most refrigerators.
Product may not be exactly as illustrated.
This trademark is registered with the U.S. Patent and Trademark Office. 27
-
7/21/2019 Vi_PriceList1_2-19-15
30/12428
VITODENS 200-WMultiple Boiler Installations
Vitodens 200-WMultiple Boiler Installations
Vitodens 200-W Config No. Configuration Drawing (Top View) Componentry
2 boilersin- line
1 Manifold: 7537703 (1)Fittings 1: 7535929 (2)Fittings 2: 7535930 (1)Fittings 3: 7535931 (1)LLH: sized as needed (1)
3 boilersin- line
2 Manifold: 7537704 (1)Fittings 1: 7535929 (3)Fittings 2: 7535930 (1)Fittings 3: 7535931 (1)LLH: sized as needed (1)
4 boilersin- line
3 Manifold: 7537703 (2)Fittings 1: 7535929 (4)Fittings 2: 7535930 (2)
Fittings 3: 7535931 (1)LLH: sized as needed (1)
4 boilersback to back
4 Manifold: 7537703 (2)Fittings 1: 7535929 (4)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1
5 boilersback to back
5 Manifold: 7537703 (1)7537704 (1)
Fittings 1: 7535929 (5)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)
LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)
6 boilersback to back
6 Manifold: 7537704 (2)Fittings 1: 7535929 (6)Fittings 2: 7535930 (2)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1
7 boilersback to back
7 Manifold: 7537703 (2)7537704 (1)
Fittings 1: 7535929 (7)Fittings 2: 7535930 (3)
Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1
8 boilersback to back
8 Manifold: 7537703 (4)Fittings 1: 7535929 (8)Fittings 2: 7535930 (4)Fittings 3: 7535931 (1)LLH: sized as needed (1)Y-Piece: 7537721 (1)Adaptor: 7201963 (1)1
1 An adaptor set is only required if manifolds are connected directly to 400/200 LLH or larger; or if a Y-piece is connected to a LLHsmaller than 400/200
-
7/21/2019 Vi_PriceList1_2-19-15
31/124
This trademark is registered with the U.S. Patent and Trademark Office. 29
VITODENS 200-WMultiple Boiler Installations
Vitodens 200-WMultiple Boiler Installations
In-line Back to Back
Vitodens 200-WMultiple Low LossDistribution Manifold(MANIFOLD ONLY)
2 boilersin-line
3 boilersin-line
4 boilersin-line
4 boilersb-to-b
5 boilersb-to-b
6 boilersb-to-b
7 boilersb-to-b
8 boilersb-to-b
ConfigurationDrawing No.
No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8
for B2HA 45 ZK012033,958.
ZK012044,646.
ZK012057,079.
ZK012068,912.
ZK012079,600.
ZK0120810,528.
ZK0120912,293.
ZK0121014,966.
for B2HA 60 ZK012033,958.
ZK012114,860.
ZK012057,079.
ZK012068,912.
ZK012129,840.
ZK0120810,528.
ZK0121312,963.
ZK0121415,182.
for B2HA 80 ZK012154,172.
ZK012114,860.
ZK012167,319.
ZK012179,152.
ZK0121810,056.
ZK0121910,744.
ZK0121312,963.
ZK0122015,237.
for B2HA 100 ZK012154,172.
ZK012215,100.
ZK012227,535.
ZK012239,368.
ZK0121810,056.
ZK0122410,799
ZK0122513,018.
ZK0122616,138.
for B2HA 112 ZK012154,172.
ZK011735,316.
ZK012227,535.
ZK012239,368.
ZK0117610,111.
ZK0122410,799.
ZK0117813,919.
ZK0122616,138.
for B2HA 150 ZK011724,412.
ZK011735,316.
ZK011748,542.
ZK011759,423.
ZK0117610,111.
ZK0117711,700
ZK0117813,919.
ZK0117916,629.
*BOILERS not included in the packages listed above
-
7/21/2019 Vi_PriceList1_2-19-15
32/124
Vitodens 200-W
Sample Dimensions
n 7 boiler manifoldn size B2HA 150 boiler
(maximumdimensions given)
Technical Data
A B C D LLH Size E F G H
All dimensions areestimates as at 9/2013
912314 92
2352 16
420 9229 160/80
200/120
250/150
300/200
400/200
450/250
500/300
19
486195002155023600
277003385035900
45
1152 67
1712 75
1920 inchesmminchesmminchesmminchesmminchesmminchesmminchesmm
VITODENS 200-WMultiple Boiler Installations
H
B C D E
G
A
F
30
-
7/21/2019 Vi_PriceList1_2-19-15
33/124
Vitodens 200-WMultiple Boiler Installations
Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-W B2HA 45 B2HAB47 B2HAB48 B2HAB49 B2HAB50 B2HAB51 B2HAB52 B2HAB53 B2HAB54 Order No
Total Input Total OutputTotal Package List Price
320292
16,302.
480438
22,174.
640584
29,658.
640584
31,140.
800730
37,012.
960876
43,106.
11201022
50,392.
12801168
57,679.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 45 2xB2HAA90
3xB2HAA90
4xB2HAA90
5xB2HAA90
6xB2HAA90
7xB2HAA90
8xB2HAA90
QtyBlr ModeOrder No
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No
KMK BUS Communication ModuleRequired for each ViessmannBoiler controlled by cascadecontrol
2x7441 586 3x7441 586 4x7441 586 5x7441 586 6x7441 586 7x7441 586 8x7441 586 QtyOrder No
Circulation PumpUPS 26-99FC 120/1/60
2x7248 585
3x7248 585
4x7248 585
5x7248 585
6x7248 585
7x7248 585
8x7248 585
QtyOrder No
Neutralization SystemTo neutralize acidic condensate,includes pellets
QtyOrder No
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No
Manifold 1 1x7537 703
1x7537 704
2x7537 703
1x7537 703
2x7537 704
2x7537 703
4x7537 703
QtyOrder No
Manifold 2 1x7537 704
1x7537 704
QtyOrder No
Low Loss Header 1x7537 705
160/80
1x7537 706200/120
1x7537 707250/150
QtyOrder No
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No
Fittings 3 QtyOrder No
Y-Piece 1x7537 721
QtyOrder No
Adapter Set 1x7201 963
QtyOrder No
VITODENS 200-W
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with any boilerother than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options (notincluded inPackage Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
Multiple Boiler Installations
N/A N/A N/A
N/A
N/A
1x7202 856 Applicable for all sizes
1x7441 823 Applicable for all sizes
1x7535 931 Applicable for all sizes
This trademark is registered with the U.S. Patent and Trademark Office. 31
-
7/21/2019 Vi_PriceList1_2-19-15
34/124
Vitodens 200-WMultiple Boiler Installations
Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-W B2HA 60
Total InputTotal OutputTotal Package List Price
B2HAB55
424388
17,816.
B2HAB56
636582
24,643.
B2HAB57
848776
32,687.
B2HAB58
848776
34,169.
B2HAB59
1060970
41,020.
B2HAB60
12721164
47,649.
B2HAB61
14841358
55,892.
B2HAB62
16961552
63,936.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 60 2xB2HAA91
3xB2HAA91
4xB2HAA91
4xB2HAA91
5xB2HAA91
6xB2HAA91
7x7533 377
8xB2HAA91
QtyBlr ModelOrder No.
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No.
KMK BUS Communication Module
Required for each ViessmannBoiler controlled by cascadecontrol
2x
7441 586
3x
7441 586
4x
7441 586
4x
7441 586
5x
7441 586
6x
7441 586
7x
7441 586
8x
7441 586
Qty
Order No.
Circulation PumpUPS 26-99FC 120/1/60
2x7248 585
3x7248 585
4x7248 585
4x7248 585
5x7248 585
6x7248 585
7x7248 585
8x7248 585
QtyOrder No.
Neutralization SystemTo neutralize acidic condensate,includes pellets
QtyOrder No.
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No.
Manifold 1 1x7537 703
1x7537 704
2x7537 703
1x7537 703
2x7537 704
2x7537 703
4x7537 703
QtyOrder No.
Manifold 2 1x7537 704
1x7537 704
QtyOrder No.
Low Loss Header 1x7537 705
160/80
1x7537 706200/120
1x7537 707250/150
1x7537 708300/200
QtyOrder No.
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No.
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No.
Fittings 3 Qty
Order No.
Y-Piece 1x7537 721
QtyOrder No.
Adapter Set 1x7201 963
QtyOrder No.
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options(notincluded in Package Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
VITODENS 200-WMultiple Boiler Installations
N/A
N/A
N/A
N/A N/A
1x
7535 931 Applicable for all sizes
1x7441 823 Applicable for all sizes
1x7202 856 Applicable for all sizes
32
-
7/21/2019 Vi_PriceList1_2-19-15
35/124
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options(notincluded in Package Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
Vitodens 200-WMultiple Boiler Installations
Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-W B2HA 80
Total InputTotal OutputTotal Package List Price
B2HAB63
570520
20,676.
B2HAB64
855780
28,641.
B2HAB65
11401040
38,241.
B2HAB66
11401040
39,712.
B2HAB67
14251300
47,876.
B2HAB68
17101560
55,841.
B2HAB69
19951820
65,219.
B2HAB70
22802080
74,867.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 80 2xB2HAA92
3xB2HAA92
4xB2HAA92
4xB2HAA92
5xB2HAA92
6xB2HAA92
7xB2HAA92
8xB2HAA92
QtyBlr ModelOrder No.
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No.
KMK BUS Communication Module
Required for each ViessmannBoiler controlled by cascadecontrol
2x
7441 586
3x
7441 586
4x
7441 586
4x
7441 586
5x
7441 586
6x
7441 586
7x
7441 586
8x
7441 586
Qty
Order No.
Circulation PumpUPS 26-99FC 120/1/60
2x7248 585
3x7248 585
4x7248 585
4x7248 585
5x7248 585
6x7248 585
7x7248 585
8x7248 585
QtyOrder No.
Neutralization SystemTo neutralize acidic condensate,includes pellets
QtyOrder No.
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No.
Manifold 1 1x7537 703
1x7537 704
2x7537 703
1x7537 703
1x7537 704
2x7537 703
4x7537 703
QtyOrder No.
Manifold 2 1x7537 704
1x7537 704
QtyOrder No.
Low Loss Header 1x7537 706200/120
1x7537 707
250/150
1x7537 708300/200
1x7537 709400/200
QtyOrder No.
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No.
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No.
Fittings 3 Qty
Order No.
Y-Piece 1x7537 721
QtyOrder No.
Adapter Set 1x7201 963
QtyOrder No.
VITODENS 200-WMultiple Boiler Installations
This trademark is registered with the U.S. Patent and Trademark Office. 33
1x7202 856 Applicable for all sizes
1x7441 823 Applicable for all sizes
1x
7535 931 Applicable for all sizes
N/A
N/A
N/A
N/A N/A
-
7/21/2019 Vi_PriceList1_2-19-15
36/124
Vitodens 200-WMultiple Boiler Installations Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-WB2HA 100
Total InputTotal OutputTotal Package List Price
B2HAB71
704666
23,185.
B2HAB72
1056999
32,626.
B2HAB73
14081332
43,458.
B2HAB74
14081332
44,929.
B2HAB75
17601665
54,148.
B2HAB76
21121998
63,638.
B2HAB77
24642331
74,673.
B2HAB78
28162664
86,138.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 100 2xB2HAA93
3xB2HAA93
4xB2HAA93
4xB2HAA93
5xB2HAA93
6xB2HAA93
7xB2HAA93
8xB2HAA93
QtyBlr ModelOrder No.
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No.
KMK BUS Communication Module
Required for each ViessmannBoiler controlled by cascadecontrol
2x
7441 586
3x
7441 586
4x
7441 586
4x
7441 586
5x
7441 586
6x
7441 586
7x
7441 586
8x
7441 586
Qty
Order No.
Circulation PumpUPS 26-99FC 120/1/60
2x7248 585
3x7248 585
4x7248 585
4x7248 585
5x7248 585
6x7248 585
7x7248 585
8x7248 585
QtyOrder No.
Neutralization SystemTo neutralize acidic condensate,includes pellets
2x7441 823
QtyOrder No.
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No.
Manifold 1 1x7537 703 1x7537 704 2x7537 703 1x7537 703 2x7537 704 2x7537 703 4x7537 703 QtyOrder No.
Manifold 2 1x7537 704
1x7537 704
QtyOrder No.
Low Loss Header 1x7537 706200/120
1x7537 707250/150
1x7537 708300/200
1x7537 709400/200
1x7537 710450/250
QtyOrder No.
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No.
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No.
Fittings 3 QtyOrder No.
Y-Piece 1x7537 721
QtyOrder No.
Adapter Set 1x7201 963
QtyOrder No.
VITODENS 200-WMultiple Boiler Installations
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options(notincluded in Package Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
34
1x7202 856 Applicable for all sizes
1x7535 931 Applicable for all sizes
1x7441 823
N/A
N/A
N/A
N/A N/A
-
7/21/2019 Vi_PriceList1_2-19-15
37/124
Vitodens 200-WMultiple Boiler Installations Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-W B2HA 112Total InputTotal OutputTotal Package List Price
B2HAB79
798750
25,174.
B2HAB80
11971125
35,808.
B2HAB81
15961500
47,435.
B2HAB82
15961500
48,905.
B2HAB83
19951875
59,389.
B2HAB84
23942250
70,006.
B2HAB85
27932625
82,464.
B2HAB86
31923000
94,091.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 112 2xB2HAA94
3xB2HAA94
4xB2HAA94
4xB2HAA94
5xB2HAA94
6xB2HAA94
7x7533 380
8xB2HAA94
QtyBlr ModeOrder No
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No
KMK BUS Communication ModuleRequired for each ViessmannBoiler controlled by cascadecontrol
2x7441 586
3x7441 586
4x7441 586
4x7441 586
5x7441 586
6x7441 586
7x7441 586
8x7441 586
QtyOrder No
Circulation PumpUPS 26-150F 120/1/60
2x7441 596
3x7441 596
4x7441 596
4x7441 596
5x7441 596
6x7441 596
7x7441 596
8x7441 596
QtyOrder No
Neutralization SystemTo neutralize acidic condensate,includes pellets
2x7441 823
QtyOrder No
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No
Manifold 1 1x
7537 703
1x
7537 704
2x
7537 703
1x
7537 703
2x
7537 704
2x
7537 703
4x
7537 703
Qty
Order No
Manifold 2 1x7537 704
1x7537 704
QtyOrder No
Low Loss Header 1x7537 706200/120
1x7537 708300/200
1x7537 709400/200
1x7537 710450/250
QtyOrder No
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No
Fittings 3 QtyOrder No
Y-Piece 1x7537 721
QtyOrder No
Adapter Set 1x7201 963
QtyOrder No
VITODENS 200-WMultiple Boiler Installations
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.f Use only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options(notincluded in Package Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
This trademark is registered with the U.S. Patent and Trademark Office. 35
1x7202 856 Applicable for all sizes
1x7535 931 Applicable for all sizes
1x7441 823
N/A
N/A
N/A
N/A N/A
1x7537 707250/150
-
7/21/2019 Vi_PriceList1_2-19-15
38/124
Vitodens 200-WMultiple Boiler Installations
Number of Boilers in Each Package
2 3 4 4 5 6 7 8
Vitodens 200-W B2HA 150
Total InputTotal OutputTotal Package List Price
B2HAB87
1060990
31,598.
B2HAB88
15901485
45,107.
B2HAB89
21201980
60,549.
B2HAB90
21201980
61,578.
B2HAB91
26502475
75,291.
B2HAB92
31802970
89,434.
B2HAB93
37103465
104,158.
B2HAB94
42403960
119,337.
MBHMBH
Total Package consists of the items listed below
Vitodens 200-W B2HA 150 2xB2HAA95
3xB2HAA95
4xB2HAA95
4xB2HAA95
5xB2HAA95
6xB2HAA95
7xB2HAA95
8xB2HAA95
QtyBlr ModelOrder No.
Vitotronic 300-K, MW2CCascade control for up to 8 boilers
QtyOrder No.
KMK BUS Communication ModuleRequired for each Viessmann Boilercontrolled by cascade control
2x7441 586
3x7441 586
4x7441 586
4x7441 586
5x7441 586
6x7441 586
7x7441 586
8x7441 586
QtyOrder No.
Circulation PumpUPS 26-150F 120/1/60
2x7441 596
3x7441 596
4x7441 596
4x7441 596
5x7441 596
6x7441 596
7x7441 596
8x7441 596
QtyOrder No.
Neutralization SystemTo neutralize acidic condensate,includes pellets
1x7441 823
2x7441 823
QtyOrder No
CSD-Conversion Kit 2x7841 861
3x7841 861
4x7841 861
4x7841 861
5x7841 861
6x7841 861
7x7841 861
8x7841 861
QtyOrder No.
Gas Pressure Switch 2x7842 160
3x7842 160
4x7842 160
4x7842 160
5x7842 160
6x7842 160
7x7842 160
8x7842 160
QtyOrder No.
Manifold 1 1x7537 703
1x7537 704
2x7537 703
1x7537 703
2x7537 704
2x7537 703
4x7537 703
QtyOrder No.
Manifold 2 1x7537 704
1x7537 704
QtyOrder No.
Low Loss Header 1x7537 707250/150
1x7537 708300/200
1x7537 709400/200
1x7537 710450/250
1x7537 711500/300
QtyOrder No.
Fittings 1 2x7535 929
3x7535 929
4x7535 929
5x7535 929
6x7535 929
7x7535 929
8x7535 929
QtyOrder No.
Fittings 2 1x7535 930
2x7535 930
3x7535 930
4x7535 930
QtyOrder No.
Fittings 3 QtyOrder No.
Y-Piece 1x7537 721
QtyOrder No.
Adapter Set 1x7201 963
QtyOrder No.
VITODENS 200-WMultiple Boiler Installations
1x7202 856 Applicable for all sizes
1x7535 931 Applicable for all sizes
N/A
N/A
N/A N/A
N/A N/A
36
fManifold Insulation (optional) must be installed prior to mounting boilers.f The Multiple Boiler Low-Loss Distribution Manifolds above are notfor use with anyboiler other than Vitodens 200-W, B2HA Series.f All boiler manifolds must be shipped and installed with a properly sized low-loss header.fUse only the configurations above - do notmix different boiler sizes.fMay request package without neutralization tank and receive a $424 credit.
Other Equipment / Options(notincluded in Package Standard Equipment):
n Ventingn Insulation for boiler manifoldn Insulation for low-loss headern Factory start-up
-
7/21/2019 Vi_PriceList1_2-19-15
39/124
VITODENS 200-W
This trademark is registered with the U.S. Patent and Trademark Office. 37
Multiple Boiler InstallationsSystem Components (If Rack Ordered Separately
Vitodens 200-W Number of Boilers in Each Package
2 3 4 5 6 7 8
B2HA 45 B2HAB0511,564.-
B2HAB06
16,434.-B2HAB07
21,304.-B2HAB08
26,173.-B2HAB09
31,043.-B2HAB10
35,913.-B2HAB11
40,783.-Order No.
US$
B2HA 60 B2HAB1212,984.-
B2HAB1318,706.-
B2HAB1424,332.-
B2HAB1529,959.-
B2HAB1635,586.-
B2HAB1741,213.-
B2HAB1846,840.-
Order No.
US$
B2HA 80 B2HAB1915,756.-
B2HAB2022,721.-
B2HAB2129,687.-
B2HAB2236,652.-
B2HAB2343,617.-
B2HAB2450,583.-
B2HAB2557,548.-
Order No.
US$
B2HA 100 B2HAB2618,264.-
B2HAB2726,483.-
B2HAB2834,703.-
B2HAB2942,922.-
B2HAB3051,141.-
B2HAB3159,361.-
B2HAB3267,580.-
Order No.
US$
B2HA 112 B2HAB3320,253.-
B2HAB3429,467.-
B2HAB3538,681.-
B2HAB3647,895.-
B2HAB3757,109.-
B2HAB3866,323.-
B2HAB3975,537.-
Order No.
US$
B2HA 150 B2HAB40
26,033.-
B2HAB41
38,137.-
B2HAB42
50,241.-
B2HAB43
62,345.-
B2HAB44
74,449.-
B2HAB45
86,553.-
B2HAB46
98,657.-
Order No.
US$
Standard Equipment:Vitodens 200 wall-mount boilersInstallation fittings with 30 psig pressure relief valveDouble Pipe AdaptorsOutdoor temperature sensorDHW sensorLLH sensorfill/drain valvesmounting hardwareGas Pressure Switch (for B2HA 112 and B2HA 150)Vitotronic 300-K MW2C cascade controlKMK- BUS communication module
-
7/21/2019 Vi_PriceList1_2-19-15
40/12438
Wall-Mounted Master Boiler Control
Vitotronic 300-K, MW2C Series Color touch screen
wall-mounted, digital indoor/outdoor master boiler and heating system controlfor up to 8Vitodens 200-W boilers
n with domestic hot water production features, including sensorn including strap-on supply temperature sensorfor low-loss header (NTC 10 kOhm)
n capable of communication with Vitodens 200-W via KM-BUSprotocoln capable of communication with Vitotronic 200-H via LON-BUSif equippedwith LON Communication Module (optional)With electric circuit board for the 2. and 3. heating circuit with mixing valve
7202 856
1913.
Order No.
US$
Communication
KMK Communication Moduleelectronic circuit board enabling data communication via Viessmann KMKsystem BUS between Vitotronic 300-K and Vitodens 200-W.For installation inside Vitodens 200-W.
Order one unit per Vitodens 200-W.
7441 586135.
Order No.US$
LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LONsystem BUS. For installation inside Vitotronic 300-K, MW2B.
7172 174308.
Order No.US$
LON Connecting Cable, 23ft / 7mfor data exchange between controls
7143 49552.
Order No.US$
LON Extension Jackto extend LON Connecting Cable
7143 49634.
Order No.US$
LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes
7171 78476.
Order No.US$
LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end
7143 49714.
Order No.US$
KM-BUS Expansion Moduleto connect between 2 and 9 additional devices to the KM-BUS
7133 393108.
Order No.US$
Extension Modulen wall-mounted extension module controls up to 2 circulation pumpsn *boiler set point temperaturen 1 Analog input (0-10V)n 3 Digital Inputsn 1 Output contact (potential-free)n Refer to manual for additional info
7533 426348.
Order No.US$
Extension Module AM1
wall-mounted extension module controls up to 2 circulation pumps
7533 425
334.
Order No.
US$
Solar Module SM1wall-mounted extension module with electronic differential control foruse with solar collectors when used with Vitodens boilers.
n heating output balancing and diagnostic systemn operation and display via boiler controln management of two tank systems from one collector fieldn second electronic differential controln thermostat function for supplemental heating or use of surplus heatn variable speed pump controller for solar circuit pump via pulse-widthcontrol, or for solar circuit pump with PWM-input (mfg Grundfos)
n includes one tank sensor and one collector sensorn 120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plugn To be used instead of an SCU Solar Controller
7533 427466.
Order No.US$
VITODENS 200-WMultiple Boiler InstallationsSystem Components (If Rack Ordered Separately)
-
7/21/2019 Vi_PriceList1_2-19-15
41/124
Hydronic Accessories
Viessmann Mixing ValvesViessmann Mixing Valve Motor, 120/1/60
n for Viessmann 3- and 4-way mixing valves onlyn order one mixing valve per low-temperature heating circuitn including strap-on supply temperature sensor (NTC 10 kOhm)
Maximum 2 Mixing Valves per single- or multiple-boiler application
7509 472225.
Order No.US$
Power Supply Adaptorrequired for eachViessmann mixing valve motor
n 120/1/60
7134 560174.
Order No.US$
VITODENS 200-WMultiple Boiler Installations
This trademark is registered with the U.S. Patent and Trademark Office. 39
Circulation Pumps
Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800UPS26-99FC120/1/60
7248 585391.
Order No.US$
Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800UPS26-150FC120/1/60
7441 596611.
Order No.US$
Multiple Boiler Low-Loss Distribution Manifold
Accessories
Connection Setto install a field supplied 90 elbow set
n 4 x 4 ANSI flanges with welded on 4 NPT coupling
7537 723727.
Order No.US$
Insulation
Manifold Insulation 7537 7122-boiler
668.
7537 7133-boiler1,125.
Order No.
US$
Low-Loss Header Insulation
For use with 7537705160/80
7537706200/120
7537707250/150
7537708300/200
7537709400/200
7537710450/250
7537711500/300
7537 714435.
7537 715559.
7537 716639.
7537 717727.
7537 718788.
7537 719950.
7537 7201,089
Order No.US$
Y-Piece Insulation 7537 722328.
Order No.US$
-
7/21/2019 Vi_PriceList1_2-19-15
42/12440
Hydronic Accessories
Viessmann 3-Way Mixing Valves 7134 742
308.
17134 743
328.
17134 744
368.
17134 745
413.
27134 746
506.
DiaOrder No.US$
Danfoss 3-Way Mixing Valvesn including flange setn includes actuator
2ZK01698
1,001.
3ZK01699
1,143.
4ZK01700
1,506.
5ZK01701
1,623.
6ZK01702
2,056.
DiaOrder No.US$
NeutralizationNeutralization System
n to neutralize acidic condensaten includes pellets
7441 823424.
Order No.US$
Sensors
Room Temperature Sensor (wall mount, NTC 10 kOhm)for use with Vitotrol 300AOrder Room Temperature Sensor if Vitotrol 300A cannot be installed in acentralized location to measure room temperature.
7438 537108.
Order No.US$
Remote Controls
Vitotrol 200A(KM-BUS protocol)User interface to operate one heating circuit:
n daytime temperature and operating programn with party and energy-saving buttonn display indication of outside temperature, room temperature andoperational settings
n with room temperature sensor for room-dependent activation(for heating circuit with mixing valve only)
If the Vitotrol 200A is to operate based upon room-dependent activation,ensure placement in a centralizedlocation.
7438 363162.
Order No.US$
Vitotrol 300A(KM-BUS protocol)User interface to operate one, two or three heating circuits:
n daytime temperature, set-back temperature, DHW temperature, operatingand holiday program, as well as party and energy-saving function
n timer program for heating circuits, DHW production, and DHW recirculationpump
n illuminated graphic display to show outdoor temperature, roomtemperature, operational settings together with descriptive texts
n with room temperature sensor for room-dependent activation(for heating circuit with mixing valve only)
If the Vitotrol 300A is to operate based upon room-dependent activation,ensure placement in a centralizedlocation.Order Room Temperature Sensor 7438537 if the Vitotrol 300 cannot be installedin a centralized location.
7172 619272.
Order No.US$
VITODENS 200-WMultiple Boiler Installations
-
7/21/2019 Vi_PriceList1_2-19-15
43/124
This trademark is registered with the U.S. Patent and Trademark Office. 41
Boiler/Tank Packages
Vitodens 200-W
with Vitocell tanksVitocell 100
CVA SeriesCVB Series
Indirect-fired domestic hot water storage tanksteel construction, withCeraprotect two-coat enamel finish
Vitocell 300
EVI SeriesEVB Series
Indirect-fired domestic hot water storage tankof high grade stainless steel
This trademark is registered with the U.S. Patent and Trademark Office.
Vitodens 200-W Vitocell 100 Vitocell 300
B2HA/B2HB Series
Wall-Mounted Condensing Boilerwith modulating MatriX-cylinder burnerfor room air dependent operationor room air independent operationHeating input: 12 to 530 MBH
3.5 to 155 kW
For natural gas or liquid propane gas
-
7/21/2019 Vi_PriceList1_2-19-15
44/124
Single Vitodens 200with Vitocell 300-V packages
Package No Boiler Boiler Qty Tank Tank Qty Price
B2HB010 Vitodens 200, B2HB-19 1 Vitocell 300, EVI- 53 1 5,679. US$
B2HB011 Vitodens 200, B2HB-26 1 Vitocell 300, EVI- 53 1 5,858. US$
B2HB012 Vitodens 200, B2HB-35 1 Vitocell 300, EVI- 53 1 6,065. US$
B2HAC78 Vitodens 200, B2HA-45 1 Vitocell 300, EVI- 79 1 7,396. US$
B2HAC79 Vitodens 200, B2HA-60 1 Vitocell 300, EVI- 79 1 8,153. US$
B2HAC80 Vitodens 200, B2HA-80 1 Vitocell 300, EVI- 79 1 9,491. US$
B2HAC81 Vitodens 200, B2HA-45 1 Vitocell 300, EVB- 79 1 8,183. US$
B2HAC82 Vitodens 200, B2HA-60 1 Vitocell 300, EVB- 79 1 8,940. US$
B2HAC83 Vitodens 200, B2HA-80 1 Vitocell 300, EVB- 79 1 10,279. US$
B2HAC84 Vitodens 200, B2HA-80 1 Vitocell 300, EVI- 119 1 11,176. US$
B2HAC85 Vitodens 200, B2HA-100 1 Vitocell 300, EVI- 119 1 12,483. US$
B2HAC86 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 119 1 13,159. US$
B2HAC87 Vitodens 200, B2HA-80 1 Vitocell 300, EVB- 119 1 11,194. US$
B2HAC88 Vitodens 200, B2HA-100 1 Vitocell 300, EVB- 119 1 12,448. US$
B2HAC89 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 119 1 13,443. US$
B2HAC90 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 79 2 14,387. US$
B2HAC91 Vitodens 200, B2HA-112 1 Vitocell 300, EVI- 119 2 17,385. US$
B2HAC92 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 79 2 15,962. US$
B2HAC93 Vitodens 200, B2HA-112 1 Vitocell 300, EVB- 119 2 17,792. US$
B2HAC94 Vitodens 200, B2HA-150 1 Vitocell 300, EVI- 79 2 17,277. US$
B2HAC95 Vitodens 200, B2HA-150 1 Vitocell 300, EVI- 119 2 20,366. US$
B2HAC96 Vitodens 200, B2HA-150 1 Vitocell 300, EVB- 79 2 18,852. US$
B2HAC97 Vitodens 200, B2HA-150 1 Vitocell 300, EVB- 119 2 20,682. US$
Boiler/Tank Packages
42
-
7/21/2019 Vi_PriceList1_2-19-15
45/124
Single Vitodens 200with Vitocell 100-V packages
Package No Boiler Boiler Qty Tank Tank Qty Price
B2HB013 Vitodens 200, B2HB-19 1 Vitocell 100, CVA-42 1 4,718. US$
B2HB014 Vitodens 200, B2HB-26 1 Vitocell 100, CVA-42 1 4,896. US$
B2HB015 Vitodens 200, B2HB-35 1 Vitocell 100, CVA-42 1 5,103. US$
B2HB016 Vitodens 200, B2HB-19 1 Vitocell 100, CVA-53 1 5,110. US$
B2HB017 Vitodens 200, B2HB-26 1 Vitocell 100, CVA-53 1 5,289. US$
B2HB018 Vitodens 200, B2HB-35 1 Vitocell 100, CVA-53 1 5,496. US$
B2HAD04 Vitodens 200, B2HA-45 1 Vitocell 100, CVA-79 1 6,602. US$
B2HAD05 Vitodens 200, B2HA-60 1 Vitocell 100, CVA-79 1 7,359. US$
B2HAD06 Vitodens 200, B2HA-80 1 Vitocell 100, CVA-79 1 8,697. US$
B2HAD07 Vitodens 200, B2HA-45 1 Vitocell 100, CVB-79 1 7,005. US$
B2HAD08 Vitodens 200, B2HA-60 1 Vitocell 100, CVB-79 1 7,762. US$
B2HAD09 Vitodens 200, B2HA-80 1 Vitocell 100, CVB-79 1 9,101. US$
B2HAD10 Vitodens 200, B2HA-80 1 Vitocell 100, CVA-119 1 9,073. US$
B2HAD11 Vitodens 200, B2HA-100 1 Vitocell 100, CVA-119 1 10,327. US$
B2HAD12 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-119 1 11,321. US$
B2HAD13 Vitodens 200, B2HA-80 1 Vitocell 100, CVB-119 1 10,104. US$
B2HAD14 Vitodens 200, B2HA-100 1 Vitocell 100, CVB-119 1 11,358. US$
B2HAD15 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-119 1 12,353. US$
B2HAD16 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-79 2 12,798. US$
B2HAD17 Vitodens 200, B2HA-112 1 Vitocell 100, CVA-119 2 13,549. US$
B2HAD18 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-79 2 13,606. US$
B2HAD19 Vitodens 200, B2HA-112 1 Vitocell 100, CVB-119 2 15,612. US$
B2HAD20 Vitodens 200, B2HA-150 1 Vitocell 100, CVA-79 2 15,688. US$
B2HAD21 Vitodens 200, B2HA-150 1 Vitocell 100, CVA-119 2 16,439. US$
B2HAD22 Vitodens 200, B2HA-150 1 Vitocell 100, CVB-79 2 16,496. US$
B2HAD23 Vitodens 200, B2HA-150 1 Vitocell 100, CVB-119 2 18,502. US$
Boiler/Tank Packages
This trademark is registered with the U.S. Patent and Trademark Office. 43
-
7/21/2019 Vi_PriceList1_2-19-15
46/12444
NOTES
-
7/21/2019 Vi_PriceList1_2-19-15
47/124
This trademark is registered with the U.S. Patent and Trademark Office. 45
VITODENS 222-F
Gas-fired, floor-standing, condensing DHW combi-boile12 to 125 MBH / 3.5 to 35 kW
Vitodens 222-F
B2TB Series
Gas-Fired Floor-StandingCondensing DHW Combi-Boilerwith modulating MatriX-cylinder burnerand DHW stainless steel tankfor room air dependent operationor room air independent operationHeating input: 12 to 125MBH
3.5 to 35kW
For natural gas or liquid propane gas
n Low cycle frequency, even with low heat demand, through optimizedpauses and wider modulation range of up to 1:6.5.
n Durable and efficientthanks to the Inox-Radial heat exchanger.
nMatriX gas burnerwith long service life thanks to stainless steel
MatriX gauze resistant to high temperature loads.
n Energy-saving, high efficiency circulation pump (DHW tank).
n Lambda Pro Controlcombustion controller for all gas types saveson costs through an extension of the inspection interval to 3 years.
n Universal connection setsfor individual installation flush with thewall.
This trademark is registered with the U.S. Patent and Trademark Office.
-
7/21/2019 Vi_PriceList1_2-19-15
48/124
Vitodens 222-F
B2TB19
B2TB35
ModelNo.
for SingleBoiler Installations only
Vitodens 222-Fwith Vitotronic 200 HO1B
Each Vitodens 222-F mustbe sold and shipped with aConnection Set
B2TB0035,337.
B2TB0045,646.
Order No.US$
Connection Setfor left/right connection
7201 537328.
Order No.US$
Connection Setfor top connection
7201 538
328.
Order No.
US$
Total List Price
Input Range
Output Range
12-683.5-20
10.9-643.2-19
5,665.
19-1255.5-37
17.4-1175.1-34
5,974.
MBHkW
MBHkW
US$
VITODENS 222-F
f Boiler standard working pressure: 30 psig;For 45 psig, order optional PRV 9549 944, List Price $35..f Boiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
Standard Equipment:Wall-mount boiler with integrated 26 USG / 100 ltr DHW tank,Vitotronic 200 HO1B, Connection Set, and installation fittings.
Technical Data
DimensionsLength
Width
Height
23595235/8600
641625
23595235/8600
641625
inchesmminchesmminchesmm
Boiler Vent Connectionflue gas / fresh air 60/100 60/100 mm
Boiler Pressure Relief Valve 30 30 psig
DHW Pressure Relief Valve 150 150 psig
DHW Storage Tank 26100
26100
USGltr
Shipping Weight (incl. fittings)not including vent system
311141
311141
lbskg
46
-
7/21/2019 Vi_PriceList1_2-19-15
49/124
VITODENS 222-F
Controls and Accessories
This trademark is registered with the U.S. Patent and Trademark Office. 47
Accessories
Communication
LON Connecting Cable, 23ft / 7mfor data exchange between controls
7143 49552.
Order No.US$
LON Extension Jackto extend LON Connecting Cable
7143 49634.
Order No.US$
LON Connecting Terminal (RJ, 2 Pieces)to connect to field cabling via wall-mount boxes
7171 78476.
Order No.US$
LON Terminal Resistor(2 Pieces)to terminate the system BUS, a resistor must be installed on each free end
7143 49714.
Order No.US$
LON Communication Moduleelectronic circuit board enabling data communication via Viessmann LON
system BUS. For installation inside Vitodens 200-W.
7179 113328.
Order No.US$
Expanded Functions
Extension Module AM1wall-mounted extension module controls up to 2 of the following circulationpumps:
n DHW recircula