Defining Automatic Seismic Static Load Cases in ETABS and SAP2000
View Results of your Multiple Load Cases in a single Output Report 1.
-
Upload
christian-brierton -
Category
Documents
-
view
216 -
download
1
Transcript of View Results of your Multiple Load Cases in a single Output Report 1.
1
View Results of your View Results of your Multiple Load Cases in Multiple Load Cases in a single Output Reporta single Output Report
View Results of your View Results of your Multiple Load Cases in Multiple Load Cases in a single Output Reporta single Output Report
www.pipingsolutions.com
TRIFLEX® Windows
2
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
•View Results of your Multiple Load Cases in a single Output Report.
•In TRIFLEX you can select the following reports: •Restraint Forces and Moments
•System Forces and Moments
•Anchor Forces and Moments
•Piping System Movements
•Anchor Movements
•Restraint Movements
•(more in the future)
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
3
Using Using TRIFLEX®Windows version 2.6.2 or greaterversion 2.6.2 or greater
This is only one example.
Now we want the Loads on Anchor Point 10 but, ALL load cases in one table
For comparison
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
4
Run the Analysis, then Run the Analysis, then Output, View Analysis Output, View Analysis
ResultsResults Output,
View Analysis Results.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
5
Now choose Anchor Now choose Anchor Forces and Moments from Forces and Moments from
the Output Tablesthe Output Tables
Output Table,
Anchor Forces and Moments.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
6
Control – Click, on the line Control – Click, on the line for Anchor Node Point 10for Anchor Node Point 10
Control - Click,
Anchor Node Point 10.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
7
Click the radio button for, Click the radio button for, Order by Case.Order by Case.
Click,
Order By Case.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
8
Note: the two additional buttons Note: the two additional buttons that are now added.that are now added.
Here I selected:
Show Base Operating Cases.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
9
Note: the two additional buttons Note: the two additional buttons that are now added.that are now added.
Here I selected:
Show All Cases.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
10
The User can now use this The User can now use this table for a Written Report.table for a Written Report.
The User can now copy this Table to his Final Written Report.
Using previous techniques developed in TRIFLEX®Windows.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
11
But now we want the Vertical Loads onlyBut now we want the Vertical Loads onlyon Five Restraints. on Five Restraints.
But across all Load Cases.But across all Load Cases.
Now we will show a different example.
The Five Vertical Restraints shown with the Up Arrows.
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
12
Now choose Restraint Now choose Restraint Forces and Moments from Forces and Moments from
the Output Tablesthe Output Tables
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
13
Choose the Five Cells which Choose the Five Cells which correspond to the Vertical Load on correspond to the Vertical Load on
its associated Restraint.its associated Restraint.
Control Click to select each Cell
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
14
The Result for selected cells:The Result for selected cells:
The User can now copy this Table to his Final Written Report.
Using previous techniques developed in TRIFLEX®Windows
www.pipingsolutions.com
TRIFLEX® Windows
Multiple Load Cases – Multiple Load Cases – Single ReportSingle Report
15
For more details please contact:
6219 Brittmoore Road
Houston, Texas 77041-5114 U.S.A.
Voice: 713 849 3366
Fax: 713 849 3654