    PVH Piston PumpsHigh flow, high performance pumpsfor industrial and mobile applications

    Revised 9/93 GBC2010

    Vickers

    Piston Pumps

  • 8/12/2019 Vickers h Series

    2/272

    Introduction

    PVH high flow, high performance pumpsare a family of variable displacement,inline piston units that incorporate theproven design, quality manufacturingtechniques and operating features ofother Vickers piston pumps, but in asmaller, lighter package.

    The PVH series has been speciallydesigned to meet the 250 bar (3625 psi)continuous duty performancerequirements of new generationequipment designs.

    These are efficient , reliable pumps, witha selection of optional controls formaximum operational flexibility.Designed specifically for strenuousapplication, they provide the productivitygains and controllability improvementsdesired in earthmoving, construction,machine tool, plastics, and all otherenergy-conscious markets. As with allVickers products, these pumps havebeen fully laboratory tested and fieldproven.

    PVH Series BenefitsVersatile design includes singlepumps, thru-drive arrangements, anda variety of drive shaft and controloptions that will adapt to anyapplication and provide the most costeffective installation.

    Proven components designed into aheavy duty, compact housing toprovide 250 bar (3625 psi) continuousoperating performance, and 280 bar(4050 psi) operating performance in aload sensing system. This design

    assures long life at the higherperformance levels required of today spower-dense machinery.

    Compact and lightweight design toreduce the application weight, andprovide better access for installationand servicing.

    Service kits developed for themost critical rotating and controlcomponents to simplify and assuresuccessful pump servicing..

    Quiet designs available fornoise-sensitive industrialapplications, reducing soundlevels further to provide a moreacceptable environment.

    Designed for maximum efficiency inany type of application. A variety ofcompensators provide the mosteffective system control, and the95%-plus volumetric efficiency meansmore flow, and more input energy, isdirected to the work and not into heat

    and waste.

    Heavy duty bearings and shafts resultin minimum internal deflections andwear, providing for longer life andmaximum uptime.

  • 8/12/2019 Vickers h Series

    3/273

    Table of Contents

    Model Codes 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Performance Data Rated characteristics 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Performance curves 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Response data 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sound levels 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Control OptionsPressure compensator 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Load sensing and pressure compensator 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remotely controllable pressure compensator with load sensing option 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pressure and torque limiter control 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pressure and torque limiting plus load sensing 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Input Shaft Selection Data 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Input Shaft Dimensions 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installation DimensionsBasic pumps (non-thru-drive) 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Adjustable maximum volume stop 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Thru-drive pumps 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ISO pump mounting flange 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Combination 2-bolt/4-bolt SAE pump mounting flange 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Rear cover for thru-drive pump 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pumps for shaft-up operation 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Foot mounting kit 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Application DataHydraulic fluids and temperature ranges 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fluid cleanliness 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Drive data 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Weights, Ordering, Installation and Start-up 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 8/12/2019 Vickers h Series

    4/274

    Model Codes

    Blank = No additional controls V = Load sensing, 20 bar

    (290 psi) differentialpressure setting

    T = Torque limiter VT = Load sensing and

    torque limiter

    Blank = Design for mobile applicationsQI = Quiet design for industrial

    applications

    N = ISO 3019/2-E32N short straightkeyed (Must use M mtg. flg.)

    1 = SAE C straight keyed(J744-32-1)

    2 = SAE C splined 14 tooth12/24 D.P. (J744-32-4)

    3 = SAE CC splined 17 tooth12/24 D.P. (J744-38-4)

    12 = SAE D splined 13 tooth8/16 D.P. (J744-44-4)

    13 = SAE CC straight keyed(J744-38-1)

    16 = SAE D straight keyed(J744-44-1)

    Blank = Non-thru-drive (single pump)A = Thru-drive pump with

    SAE A 2-bolt rear flangemounting (SAE J744-82-2)

    B = Thru-drive pump with SAE B 2- and 4-bolt rear flangemountings (SAEJ744-101-2/4)

    C = Thru-drive pump with SAE C 2- and 4-bolt rear flangemountings (SAEJ744-127-2/4)

    S = Adjustable maximum volumestop (non-thru-drive andnon-torque-control modelsonly)

    (Use with T and VT above)** = Customer desired torque limiter

    setting specified in ten bar(145 psi) increments, e.g.:8 = 80 bar (1160 psi);18 = 180 bar (2610 psi).

    C = 70-250 bar (1015-3625 psi)

    CM = 40-130 bar ((580-1885 psi)IC = Industrial control, 20 bar(290 psi) differential pressure setting (QI modelsonly)

    Shaft seal, prime mover endS = Single, one-way.

    D = Double, two-way.Recommended on secondpump of tandem assembly(PVH**/ PVH**) and wetmount applications.

    Maximum geometricdisplacement

    4

    6

    8

    10

    57 = 57,4 cm 3 /r (3.5 in 3 /r) 74 = 73,7 cm 3 /r (4.5 in 3 /r) 98 = 98,3 cm 3 /r (6.0 in 3/ r)131 = 131,1 cm 3 /r (8.0 in 3/ r)

    7

    11

    Mouting flange, primemover end

    Configuration

    Main ports F = SAE 4-bolt flange portsM = SAE 4-bolt flange ports with

    metric mounting bolt threads

    Shaft-end type, at primemover end

    (See torque limits on page 14 andshaft dimensions on page 15.)

    9

    Pump design number

    Pressure compensator andadjustment range

    Shaft rotation, viewed atprime mover end

    5

    2

    Additional control functions13

    Torque limiter factory setting14

    15 Control design number31 = C, CM, C**V, or IC

    controls

    13 = C**T controls14 = C**VT controls

    Built from pump with SAE A rear pad towhich suitable flange adapter is bolted.

    For best availability and flexibility, order PVH SAE A thru-drive pump and SAE B or C adapter kit separately. ( See page 23.)

    10 (Subject to change. Installationdimensions unaltered for designnumbers 10 to 19 inclusive.)

    12

    25 = Normal factory setting of 250bar (3625 psi) for C models.

    7 = Normal factory setting of 70 bar(1015 psi) for CM models.

    Pressure compensator factorysetting in tens of bar

    16 Special features suffix027 = Composite 2-bolt/4-bolt

    mounting conforming to SAEC (except PVH131)

    031 = Thru-drive SAE A pad cover041 = No case-to-inlet relief valve (for

    use with supercharged circuits).3,4 bar (50 psi) maximuminlet pressure

    057 = Shaft-up operation(vertical mount)

    Pump series1

    Design/application3

    Note: Unloading valve controls foraccumulator circuits are available. Seeyour Vickers representative for circuitreview and approval..

    C = SAE C 4 bolt type(SAE J744-127-4)

    M = ISO 3019/2 125B4HW(Option for PVH57 and PVHonly. Must use N shaft.)

    R = Right hand (clockwise) L = Left hand (counterclockwise)

    1 3 4 5 876 9 102 11 12 13 14 15 16

  • 8/12/2019 Vickers h Series

    5/275

    Performance Data

    Parameters PVH57QI PVH74QI PVH98QI PVH131QI Geometric displacement, max.cm 3 /r 57,4 73,7 98,3 131,1(in3 /r) (3.5) (4.5) (6.0) (8.0)Rated pressure 250 250 250 250bar (psi) (3625) (3625) 3625) (3625) Rated speeds in r/min at various inlet pressures127 mm Hg (5 Hg) 1500 1500 1500 1200Zero inlet pressure 1800 1800 1800 15000,48 bar (7 psi) 1800 1800 1800 1800Typical effective flow in l/min (USgpm) at 250 bar (3625 psi)at 1500 r/min 83 102 140 186

    (22) (27) (37) (49)at 1800 r/min 98 125 170 223(26) (33) (45) (59)

    Rated Characteristics of PVH***QI Industrial Pumps

    1500 rpm for PVH131 only. 1200 rpm for PVH131 only.

    Rated speeds in r/min at various inlet pressures127 mm Hg (5 Hg) 2000 1850 1750 1650Zero inlet pressure 2400 2200 2100 20000,48 bar (7 psi) 3000 2750 2600 2500Typical effective flow in l/min (USgpm) at 250 bar (3625 psi)and rated speed 134 156 202 249zero inlet pressure (35) (41) (53) (66)

    Performance data is typical with SAE 10W anti-wear hydraulic oil at 50 C(120 F) and at zero pump inlet pressure, except where otherwise indicated.

    Petroleum Polyol ester Water glycol HWBF(9010)Parameters based thickenedMax. pressure 250 230 172 155bar (psi) (3625) (3300) (2500) (2250)Max. speed in r/min at:1,0 bar abs. (0 psi) 1800 1800 1800 1700

    0,85 bar abs. (5 Hg) 1500 1500 1500 1500Max. inlet temp. 93 65 50 50deg. C (deg. F) (200) (150) (120) (120)

    Ratings of PVH***QI Industrial Pumps withAlternate Fluids

    Rated Characteristics of PVH*** Mobile PumpsParameters PVH57 PVH74 PVH98 PVH13 1

    Displacements & rated pressure are same as for PVH***QI industrial pumps.

    In load sensing systems the compensator can be set at 280 bar (4060 psi).

  • 8/12/2019 Vickers h Series

    6/276

    Performance Data

    Input power

    (161) 120(134) 100(107) 80 (81) 60 (54) 40 (27) 20 0 0

    (hp) kw

    (161) 120(134) 100(107) 80 (81) 60 (54) 40 (27) 20 0 0

    250 bar (3625 psi)200 bar (2900 psi)150 bar (2175 psi)100 bar (1450 psi)50 bar (725 psi)

    l/min (USgpm)

    Delivery

    36252900

    Delivery and efficiency versus outlet pressure at 1800 r/min

    PVH74

    Delivery and efficiency versus outlet pressure at 1800 r/min

    Input torque and power versus outlet pressure at 1800 r/min Input torque and power versus outlet pressure at 1800 r/min

    Input power versus speed Input power versus speed

    Efficiency %

    0 50 100 150 200

    0 725 1450 2175

    100

    80

    0

    20

    40

    60

    250Outlet pressure, bar

    Outlet pressure (psi)

    Efficiency %

    0 50 100 150 200

    100

    80

    20

    40

    60

    250Outlet pressure, bar

    Outlet pressure (psi)362529000 725 1450 2175

    362529000 725 1450 2175

    Outlet pressure, bar

    Outlet pressure (psi) Outlet pressure (psi)

    0 50 100 150 200 250

    600 1000 1500 2000Speed r/min

    1000 1500 2000Speed r/min

    l/min (USgpm)

    Delivery

    kw (hp)Input torque Input torque

    kw (hp)lb. ft. Nm lb. ft. Nm

    Volumetric efficiency

    Effective flow (delivery)

    362529000 725 1450 2175

    50 100 150 200 250

    0

    250 bar (3625 psi)200 bar (2900 psi)150 bar (2175 psi)100 bar (1450 psi)50 bar (725 psi)

    Input torque

    Input power, full stroke

    Input power, cutoffInput power, cutoff

    Input power, full stroke

    Input torque

    Volumetric efficiency

    Overall efficiency

    Effective flow (delivery)

    Overall efficiency

    PVH57

    600

    (hp) kwInput power

    Outlet pressure, bar

    (66)

    (53)

    (40)

    (26)

    (13)

    (0)

    250

    200

    150

    100

    50

    0

    (66)

    (53)

    (40)

    (26)

    (13)

    (0)

    250

    200

    150

    100

    50

    0

    600

    500

    400

    300

    200

    100

    0

    (322)

    (268)

    (215)

    (161)

    (107)

    (54)

    (0)

    240

    200

    160

    120

    80

    40

    0

    (443)

    (369)

    (295)

    (221)

    (148)

    (74)

    (0)

    600

    500

    400

    300

    200

    100

    0

    (322)

    (268)

    (215)

    (161)

    (107)

    (54)

    (0)

    240

    200

    160

    120

    80

    40

    0

    (443)

    (369)

    (295)

    (221)

    (148)

    (74)

    (0)

  • 8/12/2019 Vickers h Series

    7/277

    Performance Data

    600

    500

    400

    300

    200

    100

    0

    (hp) kwInput power

    (161) 120(134) 100(107) 80 (81) 60 (54) 40 (27) 20 0 0

    (hp) kwInput power

    (hp) kwInput power

    (161) 120(134) 100(107) 80 (81) 60 (54) 40 (27) 20 0 0

    (hp) kwInput power

    250 bar (3625 psi)200 bar (2900 psi)150 bar (2175 psi)100 bar (1450 psi)50 bar (725 psi)

    PVH98 PVH131

    Input power versus speed

    Input torque and power versus outlet pressure at 1800 r/min

    362529000 725 1450 2175

    Outlet pressure, bar

    Outlet pressure (psi)

    0 50 100 150 200 250

    (322)

    (268)

    (215)

    (161)

    (107)

    (54)

    (0)

    240

    200

    160

    120

    80

    40

    0

    kw (hp)Input torque(lb. ft.) Nm

    Input torque and power versus outlet pressure at 1800 r/min

    Outlet pressure (psi)

    Input torquekw (hp)lb. ft. Nm

    362529000 725 1450 2175

    50 100 150 200 250

    l/min (USgpm)

    Delivery

    36252900

    Delivery and efficiency versus outlet pressure at 1800 r/min

    Efficiency %

    0 50 100 150 200

    0 725 1450 2175

    100

    80

    0

    20

    40

    60

    250

    Volumetric efficiency

    Overall efficiency

    Effective flow (delivery)

    Outlet pressure, bar

    Outlet pressure (psi)

    l/min (USgpm)

    Delivery

    36252900

    Delivery and efficiency versus outlet pressure at 1800 r/min

    Efficiency %

    0 50 100 150 200

    0 725 1450 2175

    100

    80

    0

    20

    40

    60

    250

    Volumetric efficiency

    Overall efficiency

    Effective flow (delivery)

    Outlet pressure, bar

    (66)

    (53)

    (40)

    (26)

    (13)

    (0)

    250

    200

    150

    100

    50

    0

    Input power versus speed

    600 1000 1500 2000Speed r/min

    600 1000 1500 2000Speed r/min

    Input torque

    Input power,full stroke

    Input power, cutoff

    Input torque

    Input power,full stroke

    Input power, cutoff

    250 bar (3625 psi)200 bar (2900 psi)150 bar (2175 psi)100 bar (1450 psi)50 bar (725 psi)

    Outlet pressure (psi)

    Outlet pressure, bar

    (66)

    (53)

    (40)

    (26)

    (13)

    (0)

    250

    200

    150

    100

    50

    0

    (443)

    (369)

    (295)

    (221)

    (148)

    (74)

    (0)

    600

    500

    400

    300

    200

    100

    0

    (443)

    (369)

    (295)

    (221)

    (148)

    (74)

    (0)

    (322)

    (268)

    (215)

    (161)

    (107)

    (54)

    (0)

    240

    200

    160

    120

    80

    40

    0

  • 8/12/2019 Vickers h Series

    8/278

    Performance Data

    (5.0)

    (2.5)

    PVH131

    Performance data is typical with SAE 10W anti-wear hydraulic oil at 50 C(120 F) and at zero pump inlet pressure, except where otherwise indicated.

    Rated Speed at Reduced Displacement and Zero Inlet Pressure

    Effective Flow at Maximum Torque

    Inlet Pressure/Vacuum versus Speed, Non-QI Models

    130

    125

    120

    115

    110

    100

    105

    10 20 30 40 50 60 70 80 90 100% of maximum displacement

    600 1200 1800

    Effective flow (delivery)l/min(USgpm)

    2400Drive speed r/min

    17 bar (250 psi) _ _ _ 250 bar (3625 psi)

    PVH57PVH74

    PVH131

    PVH98

    PVH57

    PVH98PVH74

    (79) 300

    (66) 250

    (53) 200

    (40) 150

    (26) 100

    (13) 50

    (0) 0

    (7.5) 57131 98 74

    0

    0 400 800 1200 1600 2000 2400 2800Speed r/min

    3200 3600 (5)

    (0)

    0,52

    I n l e t p r e s s u r e

    I n l e t

    (psi) bar

    mm Hg(in Hg)

    Note: Speeds at 10%displacementrepresent maximumsat load-sense standbycondition. Thesespeeds must bereduced to ratedspeeds at 100%displacement beforeleaving standbycondition, or pumpdamage may result. %

    o f r a

    t e d s p e e

    d

    0,35

    0,17

    127 v a c u u m

  • 8/12/2019 Vickers h Series

    9/27

  • 8/12/2019 Vickers h Series

    10/2710

    Control Options

    The pump will provide a continuouslymodulated flow to meet changing loaddemands at a pre-adjustedcompensator pressure. At pressuresbelow the compensator setting, thepump will operate at maximumdisplacement. The compensator isavailable in two pressure ranges. TheC spring has an adjustment range of70 250 bar (1015 3625 psi). The CMspring has an adjustment range of40 130 bar (580 1885 psi).

    C(M)*V Load Sensing andPressure Compensator Control

    C or CM PressureCompensator Control

    The pump will provide power matchingof pump output to system load demand,maximizing efficiency and improvingload metering characteristics of any

    directional control valve installedbetween the pump and the load.

    Load sensing ensures that the pumpalways provides only the amount of flowneeded by the load. At the same time,the pump operating pressure adjusts tothe actual load pressure plus a pressuredifferential required for the controlaction. When the system is notdemanding power, the load sensecontrol will operate in an energy-savingstand-by mode.

    Typically, the differential pressure is thatbetween the pressure inlet and serviceport of a proportionally controlleddirectional valve, or a load sensingdirectional control valve. The standarddifferential pressure setting for loadsense is 20 bar (290 psi), but can beadjusted to between 17 and 30 bar (247and 435 psi) on the pump.

    C or CM Control

    C**V or CM*V Control

    Inlet

    Case drain

    Q

    P

    Outlet

    To load

    1,7 bar (25 psi)

    Loadsensesignal portControl

    valve

    If the load pressure exceeds thesystem pressure setting, the pressurecompensator de-strokes the pump. Theload sensing line must be as short aspossible and can also be used forremote control or unloading of the pumppressure. For remote control purposes,it is recommended that you contact yourVickers representative for the correctconfiguration of the control.

    Inlet

    Case drain

    Outlet

    To load

    1,7 bar (25 psi)

  • 8/12/2019 Vickers h Series

    11/2711

    Control Options

    IC Compensator

    Pressure Compensating Without Load Sensing

    Pressure Compensating with Load Sensing

    Pump with IC Compensator

    This pump is intended for use whenmultiple, remote, or electrically

    controlled compensating settings, withor without load sensing, are desired.

    Pressure compensation is obtainedwhen an internal plug is removed, theload-sense signal port is kept plugged,and internal pilot pressure is applied tothe spring chamber of the control spool.For pressure compensation with loadsensing, the internal plug stays, theload-sense signal port is unplugged,and pilot pressure is externally applied.

    An external relief valve (not supplied)controls spring chamber pressure.Theexternally adjustable spring determinesthe differential pressure setting of thecontrol. Outlet pressure is limited to thevalue of the spring chamber (pressureport) pressure, plus control differentialpressure.

    Spring chamber (pilot) pressure isseparated from outlet pressure by aninternal orifice. Outlet pressure shifts thespool when pressure drop across theorifice reaches the differential pressuresetting, and the pump de-strokes.

    The relief valve can be mounted to anNFPA-D03/ISO 4401-03 pad on thepump control, or remotely located viatapping and blanking plates installed onthe pad. See Ordering Procedure ,page 27, for more on valves and plates.

    The standard factory-set differentialpressure setting of the pump control is20 bar (290 psi) and is not specified inthe pump model number. Any otherordered differential pressure, within thecontrol s adjustable pressure range of17 35 bar (247 508 psi), will bespecified in the model number followingthe IC control code; for example,-IC30- for a 30 bar setting.

    Inlet

    Case drain

    Outlet

    To load

    1,7 bar (25 psi)

    Load sensesignal port

    Tank port

    Pressureport

    Inlet

    Case drain

    Outlet

    To load

    1,7 bar (25 psi)

    Load sensesignal port

    Tank port

    Pressureport

  • 8/12/2019 Vickers h Series

    12/2712

    Control Options

    C**T Pressure and TorqueLimiter Control

    The pump senses pressure and flowand starts destroking at apredetermined input torque level. Therate of flow reduction is normally tailoredto follow the maximum power capabilitycurve of the prime mover. Input torqueis limited while the pressurecompensator limits the system pressure.

    When the input speed remains constant(i.e. industrial drives), the torque limiteracts as an input power limiter. Thisallows a smaller electric motor to beused if maximum pressure and

    maximum flow are not required at thesame time. At low load levels, thecontrol permits high pump displacementand high load speeds. Under heavyloads, speed is reduced, preventingstalling of the prime mover. In the caseof variable speed drives (I.C. engines),this function provides, in addition topressure compensation or limiting, atorque limiting ability that can beadjusted to the torque/speedcharacteristics of the engine.

    The start of torque limiting(pump-destroking) is pressuredependent. This pressure is selectable(see model code) and is factory presetto between 30% and 80% of themaximum pressure control setting. Theminimum torque pressure setting is 40bar (580 psi). Example: C10T4. There isno CM spring option available with thetorque limiting control.

    C**T ControlInlet

    Case drain

    Q

    P

    Outlet

    To load

    1,7 bar (25 psi)

  • 8/12/2019 Vickers h Series

    13/2713

    Control Options

    C**VT Pressure andTorque Limiting, PlusLoad Sensing, Control

    The pump s control functions like aload sensing control, but with additionaltorque limiting tailored to the size of thedrive motor selected. The limitingfunction is the same as for a pressurecompensator with torque limiting (seeC**T description, previous page). Thecombination of the two controlsprovides the following benefits:

    1. The energy savings of a variabledisplacement load sensing control.

    2. The pump pressure follows the loadpressure.

    3. The torque control allows smallerdrive motors to be used.

    4. The pressure compensatorde-strokes the pump as maximumpressure is reached.

    5. The pump pressure can also beremotely controlled using the loadsense line. The C**VT control allowscomplete control of flow andpressure, either mechanically orelectrically, if used with proportionalvalves.

    C**VT Control

    Inlet

    Case drain

    Outlet

    To load

    1,7 bar (25 psi)

    Load sensesignal port

  • 8/12/2019 Vickers h Series

    14/2714

    Input Shaft Selection Data

    MaximumMaximum thru-drive

    Basic Thru-drive input outputShaft pump pump torque torquecode Shaft designation series series Nm (lb. in.) Nm (lb. in.)

    1 SAE C (J744-32-1) PVH57 PVH57 450 (3,980) 335 (2,965)straight keyed PVH74 450 (3,980)

    PVH98 450 (3,980)

    2 SAE C (J744-32-4) PVH57 PVH57 640 (5,660) 335 (2,965)14T 12/24 DP FRSF spline PVH74 640 (5,660)

    PVH98 640 (5,660) 3 SAE CC (J744-38-4) PVH74 1215 (10,750) 460 (4.070)

    17T 12/24 DP FRSF spline PVH98 1215 (10,750) 640 (5,660)PVH131 PVH131 1215 (10,750) 640 (5,660)

    12 SAE D (J744-44-4) PVH131 PVH131 1215 (10,750) 640 (5,660)13T 8/16 DP FRSF spline

    13 SAE CC (J744-38-1) PVH74 765 (6,770) 460 (4.070)straight keyed PVH98 765 (6,770) 460 (4.070)

    PVH131 765 (6,770)

    16 SAE D (J744-44-1) PVH131 1200 (10,620) 640 (5,660)straight keyed

    Multiple pump arrangements can beformed by a PVH thru-drive pump andany suitable pump (single or multiple)that can be installed on the SAE A,B, or C rear-mounting optionavailable for the thru-drive pump.

    Note: Any deviation from maximum input torques must be approved by Vickers.To assure developed thru-drive loads are within PVH pump limitations, actualtorque values must not exceed values shown.

    It is important to check that maximumtorque values for individual pumpsections, or complete pumps, occuring ina specific application will not exceed thelimits tabled below.

  • 8/12/2019 Vickers h Series

    15/2715

    Input Shaft Dimensions

    Shaft Numbercode Shaft designation of teeth C D2 SAE C (J744-32-4) 14 48,0 56,0

    (1.89) (2.20)3 SAE CC (J744-38-4) 17 54,0 62,0

    (2.13) (2.44)12 SAE D (J744-44-4) 13 67,0 75,0 (2.64) (2.95)* See torque limits on previous page.

    Straight Keyed Shafts *

    Spline Shafts *

    Shaftcode Shaft designation A B C D E1 SAE C (J744-32-1) 31,75 35,32 48,0 56,0 7,93

    (1.25) (1.38) (1.89) (2.20) (.312)13 SAE CC (J744-38-1) 38,10 42,39 54,0 62,0 9,52

    (1.50) (1.67) (2.12) (2.44) (.375)16 SAE D (J744-44-1) 44,45 49,46 67,0 75,0 11,11

    (1.75) (1.95) (2.64) (2.95) (.438)N ISO 3019/2 E32N 32,00 35,00 58,0 68,1 10,00

    (1.26) (1.38) (2.28) (2.68) (.393)* See torque limits on previous page.

    C

    D

    BA

    E square key

  • 8/12/2019 Vickers h Series

    16/2716

    Installation Dimensions

    Basic Pump with Pressure Compensatorand Load Sense Controls

    3rd angle projection

    For shaft options and dimensions,see pages 14 and 15.StandardSAE pump mounting flangeshown; see page 24 for optionalSAE 2-bolt/4-bolt and ISO flanges.See page 25 for shaft-up mountingoption.

    WX

    YZ

    U V

    B

    57,25(2.25)

    57,25(2.25)

    57,25(2.25)

    57,25(2.25)

    14,53 (0.57) 14,15 (0.56)

    Full R

    Optional drain port. For .500 O. D.tube, .750-16 UNF-2B thread (PVH57& 74). For .625 O. D. tube, .875 14

    UNF 2B thread (PVH98 & 131).

    C

    D

    E

    I

    JK

    M L

    Q

    R

    TS

    O

    N

    F

    G H

    Centerline of outlet port

    A

    48,00(1.89)

    No. 2shaft 12,45

    (0.49)

    Drain port. SAE O-ring boss..500 O. D. tube, .750-16 UNF-2B thread (PVH57 & 74)..626 O. D. tube, .875-14 UNF-2B thread (PVH98 & 131).

    P inlet. SAE J518C4-bolt flange port.Standard pressureseries.

    Load sensing signalport. SAE O-ringboss for .375 O. D.

    tube. .562-18 UNF-2B thread.

    Outlet port. SAE J518C 4-bolt flange.Std. pressure (code 61) series for57 to 98 sizes. High pressure (code 62)series for 131 size.

    Dimensions shown in mm (in.)

    F model: .500-13 UNC-2B thd. 1.06 deep min.for PVH57/74. 1.19 deepmin. for PVH98/131.4 holes.

    M model: M12 thd. 29deep min. for PVH57/74.31 deep min. forPVH98/131. 4 holes.

    45

    2 places

    Outlet pressuregauge port. M10thd. 25,4 (1.00)deep. O-ringboss. (plugged)

    127,00 (5.000)126.95 (4.998)

    View A-ALoad sense adjustment.Approx. 14 bar (200 psi)differential change perrevolution of screw.

    Compensator adjustment.

    Approx. 28 bar (400 psi)change per revolution ofscrew.

  • 8/12/2019 Vickers h Series

    17/2717

    Installation Dimensions

    PVH57 42,88 21,44 25,4 M10x1,5 52,37 26,18 26,19 13,10(1.69) (0.84) (1.0) (.375-16) (2.06) (1.03) (1.03) (0.52)

    PVH74 42,88 21,44 25,4 M10x1,5 52,37 26,18 26,19 13,10(1.69) (0.84) (1.0) (.375-16) (2.06) (1.03) (1.03) (0.52)

    PVH98 50,8 25,4 25,4 M10x15 52,37 26,19 26,19 13,10(2.0) (1.0) (1.0) (.375-16) (2.06) (1.03) (1.03) (0.52)

    PVH131 50,8 25,4 31,75 M14x2,0 66,68 33,34 31,75 15,88(2.0) (1.0) (1.25) (.500-13) (2.63) (1.31) (1.25) (0.63)

    PVH57 168,0 14,0 227,4 56,1 71,0 64,8 50,8 77,77 38,88(6.6) (0.55) (8.95) (2.21) (2.80) (2.55) (2.0) (3.06) (1.53)

    PVH74 174.0 15,0 250,1 56,0 70,0 68,0 50,8 77,77 38,88(6.85) (0.59) (9.85) (2.20) (2.75) (2.68) (2.0) (3.06) (1.53)

    PVH98 176,5 16,0 269,3 55,5 85,0 74,2 63,5 88,9 44,45(6.95) (0.63) (10.60) (2.18) (3.35) (2.92) (2.5) (3.50) (1.75)

    PVH131 202,0 15,0 298,6 62,0 88,8 70,6 63,5 88,9 44,45(7.95) (0.59) (11.75) (2.44) (3.50) (2.78) (2.5) (3.50) (1.75)

    S T U V W X Y Z

    J K L M N O P Q R

    A B C D E F G H I

    PVH57 76,0 71,0 293,0 216,5 171,3 86,0 79,0 88,0 69,0

    (2.99) (2.79) (11.54) (8.52) (6.74) (3.39) (3.11) (3.46) (2.71)

    PVH74 88,0 70,0 306,6 241,2 194,3 92,0 94,0 95,0 81,0(3.46) (2.75) (12.07) (9.50) (7.65) (3.62) (3.70) (3.74) (3.19)

    PVH98 93,1 85,0 323,5 251,3 206,1 94,5 87,5 97,1 80,1(3.67) (3.35) (12.74) (9.89) (8.11) (3.72) (3.44) (3.82) (3.15)

    PVH131 109,4 88,8 377,0 280,4 230,4 120,0 109,0 107,4 84,8(4.31) (3.50) (14.84) (11.04) (9.07) (4.72) (4.29) (4.23) (3.34)

    Basic Pump with Pressure Compensator and Load Sense Controls

  • 8/12/2019 Vickers h Series

    18/2718

    Installation Dimensions

    D plus 16 (.63)63,0(2.5)

    A B C D* E F G H I J

    PVH57 300,2 177,4 168,1 41,4 195,4(11.82) (6.98) (6.62) (1.63) (7.69)

    PVH74 322,9 200,1 174,1 47,9 201,4(12.71) (7.88) (6.85) (1.86) (7.93)

    PVH98 335,1 212,3 187,1 41,4 214,4(13.19) (8.36) (7.37) (1.63) (8.44)

    PVH131 359,5 236,6 202,2 63,8 229,5(14.15) (9.31) (7.96) (2.51) (9.04)

    A B C D E

    Basic Pump. Rear Viewwith Various Controls.

    Pump with Pressure Compensation, Load Sense and Torque Limit Controls

    PVH57 176,45 41,0 102,7 64,5 49,0 176,6 203,0 101,5 127,0 102,7(6.95) (1.61) (4.04) (2.54) (1.93) (6.95) (7.99) (4.00) (5.00) (4.04)

    PVH74 182,45 47,5 109,2 71,0 55,5 182,6 224,0 112,0 133,0 109,2(7.18) (1.87) (4.30) (2.79) (2.19) (7.18) (8.82) (4.41) (5.23) (4.30)

    PVH98 195.45 41,0 102,7 65,5 49,0 185,1 233,0 116,5 135,5 102,7(7.69) (1.61) (4.04) (2.54) (1.93) (7.280 (9.17) (4.59) (5.33) (4.04)

    PVH131 210,50 63,6 125,2 87,0 71,5 210,6 254,2 127,1 161,0 125,2(8.29) (2.50) (4.92) (3.42) (2.81) (8.29) (10.00) (5.00) (6.37) (4.92)

    Right hand rotation,pressure compensatedand torque limit model

    *Add 16,0 (.63) to dimension D for right hand rotation model.

    Left hand rotation, pressurecompensated and loadsensing model

    Right hand rotation,pressure compensatedmodel

    Left hand rotation, pressurecompensated with load senseand torque limit model

    BA

    E

    C

    D

    62,2(2.45)

    Optional loadsensing signal portJ . SAE O-ring bossfor .375 O. D. tube..562-18 UNF-2Bthread. (plugged)

    J

    I

    HG

    F

    CD

    E

    Optional loadsensing signal portJ. SAE O-ring bossfor .375 O. D. tube..562-18 UNF-2Bthread.

    Centerline ofload senseport for righthand rotation

    B

    A

  • 8/12/2019 Vickers h Series

    19/2719

    Installation Dimensions

    Control surface, ISO4401 size 03. Availablewith metric or UNC mounting holes to order

    25,8 (1.016)

    Pressure compensator:Remove access plug, using 1/8 inchhex wrench. Remove internal plug,using 5/32 inch hex wrench. Replaceaccess plug and torque to 12,1 12,4Nm (107 110 lb. in.). Attach relief valvehardware (not supplied) to controlsurface. See page 11 for more details.

    5,0 (.197) 2 places

    Pump with IC Compensator (Remotely Controllable PressureCompensator, and Optional Load Sensing)

    PVH57 234,5 72,5 269,9 128,0 142,0(9.23) (2.85) (10.62) (5.04) (5.59)

    PVH74 257,2 79,0 292,6 134,0 148,0(10.12) (3.11) (11.52) (5.27) (5.83)

    PVH98 269,3 72,5 304,7 136,5 150,5(10.60) (2.85) (12.00) (5.37) (5.92)

    PVH131 293,6 95,0 329,0 162,0 176,0(11.56) (3.74) (12.95) (6.38) (6.93)

    A B C D E

    Tank portPressure port

    Load sense port (if used). SAEO ring boss for .375 O. D.tube. .562 18 UNF-2B thread

    4,0 (.157)

    Load-sense port plug

    #10 24 UNC thread.57 deep minimum, orM5 14,0 deep minimum

    A

    B

    C

    D

    E

    Internal plug

    32,5 (1.279)

    40,5 (1.594)21,5 (.846)7,5 (.295)

    Access plug

    31,0 (1.220)

    5,2 (.205)15,5 (.610)

    0,75 (.029)

    Pressure compensator withload sensing:Remove load-sense port plug. (Internalplug must remain in place.) Attach lineto load-sense port. Pressure decay rateof this line must not exceed 11kbar/second (160 kpsi/second). Attachrelief valve hardware (not supplied) tocontrol surface. See page 11 for moredetails.

  • 8/12/2019 Vickers h Series

    20/2720

    Installation Dimensions

    Locknut

    Approx. displacement changeper revolution of rod:PVH57 4,25 cm 3 (0.259 in 3)PVH74 5,00 cm 3 (0.305 in 3)PVH98 6,25 cm 3 (0.381 in 3)PVH131 8,50 cm 3 (0.519 in 3)

    Adjusting rod

    Pump with Adjustable Maximum Volume Stop

    This option allows maximum pump delivery to beexternally adjusted from 25 to 100 percent. To assist

    initial priming, adjust stop to allow at least 40 percentof maximum delivery. Adjust by loosening locknut andturning adjusting rod clockwise to decrease maximumdelivery, or counterclockwise to to increase maximumdelivery. When desired setting is obtained, torquelocknut to 25-50 Nm (18-36 lb. ft.).

    A max

    B

    C

    Right handrotationmodel.

    PVH57 293,0 20,0 69.5(11.53) (.79) (2.74)

    PVH74 306,6 22,0 76,0(12.07) (.87) (2.99)

    PVH98 323,5 27,5 81,0(12.74) (1.08) (3.19)

    PVH131 377,0 37,5 88,8(14.84) (1.48) (3.50)

    A B C

  • 8/12/2019 Vickers h Series

    21/2721

    Installation Dimensions

    I J K L M N O PVH57 43,6 69,0 14,0 102,7 176,6 203,0 101,5

    (1.72) (2.71) (0.55) (4.04) (6.95) (7.99) (4.00)

    PVH74 43,8 81,0 15,0 109,2 182,6 224,0 112,0(1.72) (3.19) (0.59) (4.30) (7.18) (8.82) (4.41)

    PVH98 44,6 80,1 16,0 102,7 185,1 233,0 116,5(1.75) (3.15) (6.30) (4.04) (7.28) (9.17) (4.59)

    PVH131 44,7 84,8 15,0 125,2 210,6 254,2 127,1(1.76) (3.34) (0.59) (4.93) (8.29) (10.0) (5.00)

    A B C D E F G H

    Thru-drive Pumps with SAE A Rear Pad

    PVH57 287,9 295,4 275.8 216,4 86,0 79,0 88,0 36,4

    (11.3) (11.6) (10.86) (8.52) (3.38) (3.11) (3.46) (1.43)PVH74 310.6 318,1 300,5 241,2 92,0 94,0 95,0 38,5(12.23) (12.52) (11.83) (9.50) (3.62) (3.70( (3.74) (1.51)

    PVH98 322,8 N/A 312,7 251,3 94,5 87,5 97,1 33,0(12.71) (12.31) (9.89) (3.72) (3.44) (3.82) (1.30)

    PVH131 347,1 N/A 337,0 280,4 120,0 109,0 107,4 35,3(13.660 (13.27) (11.04) (4.72) (4.29) (4.23) (1.39)

    For shaft options and dimensions,see pages 14 and 15. See page 24for optional cover for rear pad.

    C

    D

    K

    J

    AB

    H I

    N

    O

    SAE A internalinvolute spline.9 teeth 16/32 pitch,30 pr. angle.E

    GF

    Externalinvolutespline

    Load sensingsignal port. SAEO-ring boss for

    .375 O. D. tube..562-18 UNF-2B thread.

    Right hand rotation,pressure compensatedand load sensing model.

    53,20(2.1) 53,20

    (2.1)

    53,20(2.1)

    53,20(2.1)

    L

    M

    82,63 (3.253)82,58 (3.251)

    R 1,00 (0.04) max

    9,00 (0.35)8,00 (0.31)

    Centerline of outlet port

    .375-16 UNC-2Bthread .58 deepmin., or M10 thread18,0 deep min.

    Note: The O-ring for sealing the rear mountingpad is furnished with the pump. The rear drivecoupling shown must be ordered separately;see page 23

  • 8/12/2019 Vickers h Series

    22/2722

    Installation Dimensions

    Pump A B C D Model

    57,25(2.25)

    57,25(2.25)

    A

    44,90(1.77)

    SAE B rear mounting. Mounting pad is machined toaccept AS568-155 O-ring. Mounting pad is connectedto pump case and must be sealed.

    Metric M14x2,00 M12x1,75 M16x2,0025 deep 25 deep 25 deep

    Inch 0,500-13 0.500-13 0.625-11UNC-2B UNC-2B UNC-2B1.0 deep 1.0 deep 1.0 deep

    Thru-drive Pumps with SAE B Rear Pad Adapter

    PVH57 36,4 68,8 300,4 312,9(1.43) (2.71) (11.82) (12.32)

    PVH74 33,5 68,3 323,1 335,6(1.32) (2.69) (12.72) (13.21)

    PVH98 33,0 69,8 335,3 347,7(1.30) (2.75) (13.20) (13.69)

    PVH131 35,3 69,7 359,6 372,1(1.39) (2.74) (14.16) (14.65)

    Thru-drive Pumps with SAE C Rear Pad Adapter

    Thru-drive pumps must have supportlocated by dimension C.

    Thru-drive pumps must have supportlocated by dimension C.

    D1 D2 D3

    CD

    B

    101,65 (4.002) 101,60 (4.000)

    12,50 (0.49)11,50 (0.45)

    R 1,00(0.04)max

    73,00(2.87)

    73,00(2.87)

    44,90(1.77)

    44,90(1.77)

    6 x D1

    44,90(1.77)

    92,0(3.62)

    92,0(3.62)

    4 x D287,0(3.42)

    87,0(3.42)

    35,0 (1.38) 53,0 (2.10)

    SAE BB size,side fit, internalinvolute spline.15 teeth 16/32pitch, 30 pr.angle. Or SAE Bsize, side fit,internal involutespline. 13 teeth16/32 pitch, 30 pressure angle.

    A B

    CD 127,05 (5.002)

    127,00 (5.000)

    15,50(0.61)14,50(0.57)

    R 1,00 (0.04) max

    SAE C size,side fit, internalinvolute spline. 14teeth 12/24 pitch,30 pressureangle. Or SAECC size (exceptPVH57), side fit,internal involutespline, 17 teeth12/24 pitch, 30pressure angle.

    SAE C rear mounting. Mounting pad is machinedto accept AS568-159 O-ring. Mounting padis connected to pump case and must be sealed.

    108,5(4.19)

    108,5(4.19)

    53,0

    (2.10) 35,0 (1.38)

    2 x D3

    4 x D1

    4 x D2

    92,0(3.62)

    90,50(3.56) 57,25

    (2.25)

    90,50(3.56)

    92,0(3.62)

    57,25(2.25)

    Note: The O-ring for sealing the rear mountingpad is furnished with the pump. The rear drivecouplings shown must be ordered separately;see following page.

  • 8/12/2019 Vickers h Series

    23/2723

    Mountng Piston pump Shaft Vane pump Shaftseries code series code

    SAE A PVQ10/13 3 V10 11V20 62

    SAE B PVQ20/32 3 20V 151 PVQ40/45 3 25V 11

    PVE19/21 9 V2020 11

    SAE BB PVE19/21 2TA19 2

    SAE C PVH57 2 35V 11PVH74 2 352*V 11PVH98 2

    SAE CC PVH131 3

    SAE (J744) Mounting flange adapterFront mounting kit number*

    pump flangemodel for rear Metric Inch Couplingseries pump threads threads part number**

    PVH57 A (J744-82-2) None required None required 526682B (J744-101-2/4) 876394 876390 526694BB (J744-101-2/4) 876394 876390 526695C (J744-127-2/4) 876392 876389 526696

    PVH74 A (J744-82-2) None required None required 864460B (J744-101-2/4) 876394 876390 864457BB (J744-101-2/4) 876394 876390 864459C (J744-127-2/4) 876392 876389 864458CC (J744-127-2/4) 876392 876389 864461

    PVH98 A (J744-82-2) None required None required 877039PVH131 B (J744-101-2/4) 876394 876390 877040

    BB (J744-101-2/4) 876394 876390 877044C (J744-127-2/4 876392 876389 877045CC (J744-127-2/4) 876392 876389 877046

    Thru-drive Flange Kit and Shaft Coupling

    *The basic PVH thru-drive pump has an SAE A pad on the rear. An SAE B or C pad rearmounting requires flange adapters. Required adapters can be provided if specified in thepump model code. The best combination of price, availability and flexibility is achieved byordering a PVH SAE A thru-drive model and the applicable PVH mounting flange adapterseparately. For example, a PVH74C-RCF-3S-10-C25-31 may also be ordered as aPVH74C-RAF-3S-10-C25-31 and a 876389 flange adapter.

    ** Thru-drive shaft couplings must be ordered separately to drive the second pump.

    Typical Rear Pumps for Thru-drive Assemblies

    NOTE: The above Vickers pumps are examples of rear pumps for the thru-drive pumps dimen-sioned on pages 21 and 22.The thru-drive torque limits identified in the chart on page 14 mustnot be exceeded when applying these multiple pump systems.

  • 8/12/2019 Vickers h Series

    24/2724

    13,39 (.53)

    56,57(2.23)

    56,57(2.23)

    56,57(2.23)

    45

    82,5582,45(3.250)(3.246)

    102,0 (4.01)

    17,75 (.70)17,37 (.68)2 places

    57,25(2.25)

    57,25(2.25)

    57,25(2.25)

    SAE 2 bolt/4-bolt Mounting ( 027 Option) for PVH57, PVH74 and PVH98 Pumps

    Cover ( 031 Option) for Thru-drive SAE A Rear Mounting Flange

    14,53 (.57)14,15 (.56)4 places

    45

    127,00126,95(5.000)(4.998)73,80

    72,20(2.90)(2.84)

    57,25 (2.25)6 places

    Full radius90,50(3.56)

    181,0(7.12)

    Full radius

    102,0(4.01)

    37,61(1.48)

    Optional 12,0 (.47)radius 4 places

    11,00 (.43)2 holes

    37,61(1.48)

    37,61(1.48)

    37,61(1.48)

    13,39 (.53)

    30

    1,00 (.04)

    3,50 (.138)

    0,8 (.03)R max.

    9,5 (.37)

    56,57(2.23)

    Full R

    14,37 (.56)14,00 (.55)4 places

    125,00124,94(4.921)(4.919)

    9,25 (.36)

    ISO 3019/2-125B4HW Mounting Flange for PVH57 and PVH74 Pumps

    12,45 (.49)

    Note: When cover (part number 939790)

    is ordered as a separate part, two screws(part number 170177) are required toattach the cover to the pump s rearmounting flange.

    The O-ring for sealing the rear mountingflange is furnished with each thru-drivepump.

  • 8/12/2019 Vickers h Series

    25/2725

    127,15 (5.006)

    127,05 (5.002)

    Model FB-C4-10 Foot Mounting Kit for All PVH Pumps

    73,6(2.90)

    101,8(4.00)

    228,0(8.98)

    114,0(4.5)

    114,5(4.5)

    57,25(2.25)

    11,0 thru 37,0 spotface 1,0deep

    4 places

    .500-13 UNC-2B thd.thru. 4 places.

    57,25(2.25)

    114,5

    (4.5)

    174,75(6.88)

    20,5(0.8)

    133,0(5.24)

    0,5 R

    23,0(0.90)

    18,0(0.71)

    LOX 45

    Each kit (part no. 02-143419)includes bracket shown andfour screws for mounting tothe pump. Kits are notincluded with pumps and mustbe ordered separately bymodel number.

    Dim. A

    Pumps for Shaft-up Operation (Vertical Mount, 057 Option)

    73,8072,20(2.90)(2.84)

    Attach line from this port to primary case drain line. Jointhese lines at a distance above the face of the mountingflange that equals, or is less than, dimension A. Fill case

    with fluid up to this port prior to start-up.

    Model Dim. APVH57 25,68/24.94

    (1.01/0.98)PVH74 26,64/25,90

    (1.05/1.02)PVH98 25,82/25,08

    (1.02/0.99)PVH131 25,12/24,38

    (.99/0.96)Vertical mount port.For .125 O. D. tube..3125-24 UNF-2B thread.1,59 (.0625) maximumspotface depth

  • 8/12/2019 Vickers h Series

    26/2726

    Application Data

    Hydraulic fluids andtemperature rangesUse anti-wear hydraulic oil, orautomotive type crankcase oil(designations SC, SD, SE or SF) perSAE J183 FEB80.

    Select a viscosity grade that will allowoptimum viscosity, between 40 cSt(180 SUS) and 16cSt (80 SUS), tobe achieved.

    Cold start capability at 5000 cSt.Max. intermittent temp. 104 C (220 F).

    For further information, see 694.

    Fluid cleanliness

    Proper fluid condition is essential forlong and satisfactory life of hydrauliccomponents and systems. Hydraulicfluid must have the correct balance ofcleanliness, materials and additives forprotection against wear of components,elevated viscosity and inclusion of air.

    Essential information on the correctmethods for treating hydraulic fluid isincluded in Vickers publication 561;Vickers Guide to SystemicContamination Control, available fromyour local Vickers distributor or by

    contacting Vickers, Incorporated.Recommendations on filtration and theselection of products to control fluidcondition are included in 561.

    System Pressure LevelProduct 2000 psi 2000-3000 psi 3000+ psiVane pumps, fixed 20/18/15 19/17/14 18/16/13Vane pumps, variable 18/16/14 17/15/13Piston pumps, fixed 19/17/15 18/16/14 17/15/13Piston pumps, variable 18/16/14 17/15/13 16/14/12Directional valves 20/18/15 20/18/15 19/17/14Proportional valves 17/15/12 17/15/12 15/13/11Servo valves 16/14/11 16/14/11 15/13/10Pressure/Flow controls 19/17/14 19/17/14 19/17/14Cylinders 20/18/15 20/18/15 20/18/15Vane motors 20/18/15 19/17/14 18/16/13Axial piston motors 19/17/14 18/16/13 17/15/12Radial piston motors 20/18/14 19/17/13 18/16/13

    Recommended cleanliness levels,using petroleum oil under commonconditions, are based on the highestfluid pressure levels in the system and

    are coded in the chart below. Fluidsother than petroleum, severe servicecycles or temperature extremes arecause for adjustment of thesecleanliness codes. See Vickerspublication 561 for exact details.

    Vickers products, as any components,will operate with apparent satisfactionin fluids with higher cleanliness codesthan those described. Othermanufacturers will often recommendlevels above those specified.Experience has shown, however, that life

    of any hydraulic components isshortened in fluids with highercleanliness codes than those listedbelow. These codes have been provento provide a long trouble-free service lifefor the products shown, regardless ofthe manufacturer.

    Drive data

    Mounting attitude should be horizontal.See preceding page for vertical mountoption. Consult your local Vickersrepresentative if a different arrangementis required.

    Direction of shaft rotation, viewed at theprime mover end, must be as indicatedin the model designation on the pump.See 5 in Model Codes, page 4.

    Cleanliness codes for petroleum oil usage

    Drive arrangement should be bydirect drive through a flexiblecoupling. Check pump installationdrawing for concentricity and

    squareness tolerances.

    Torque capability of shafts in basic(non-thru-drive) pumps is well in excessof that needed for operation at ratedpressure and maximum displacement.Limitations for multiple pumps formed byPVH thru-drives as front-end sections arespecified in the chart on page 14.

    Model Nm.sec 2 (lb.in.sec 2)

    Moment of Inertia (SinglePump Rotating Group)

    PVH57 0,0054 (0.0475)PVH74 0,0078 (0.0692)PVH98 0,0134 (0.1189)PVH131 0,0210 (0.1862)

  • 8/12/2019 Vickers h Series

    27/27

    Weights, Ordering, Installation/Start-up

    Ordering ProcedureOrder PVH pumps by the full modeldesignation. Pump displacement,mounting flange type, direction ofrotation, pump configuration, shaft endtype, shaft seals, pressure adjustmentrange, specific control functions, andtorque limiter settings are all specified inthe full model code.

    Various Vickers relief valves are suitablefor use with the IC compensator andmust be ordered separately.Examples include:

    DGMC2-3-AT-BT (plus DG4V-3-8Cdirectional valve) for remotely and elec-trically controlled dual-pressure com-pensation, and standby no-flow pumpoperation in the load sensing mode.

    DGMC-3-PT-FW-30 crossline reliefmodule (with DG4V3-8C directionalvalve) for electrical selection of dualpressure compensation.

    ECGF-02-9-21 proportional relief valve,with feedback, for remote control ofpressure compensation.

    ECG-02-9-30 proportional relief valvefor remote control of pressurecompensation.

    Pump Basic Thru-drive PumpSize Pump SAE A

    Weights in kg (lb)*

    PVH57 30 36 31-37(66-79) (68-82)

    PVH74 39-45 42-48(86-99) (93-106)

    PVH98 43-49 44-50(95-108) (97-110)

    PVH131 60-66 62-68(132-145) (137-150)

    *Approximate dry weights. Weight for a given model depends upon the type of pump control selected.

    DGMC-3-AT-BT (plus DG4V-3-0Adirectional valve) for remotely andelectrically selected dual-pressurecompensation.

    C175-F-20 (plus blanking plateDGMA-3-B-11 and tapping plateDGMA-T2-20-S) for remote control ofpressure compensation.

    CVGC-3-S12 for non-remote control ofpressure compensation.

    DGMC-3-PT-FW-30 crossline reliefmodule (with blanking plateDGMA-3-B-11) for non-remote controlof pressure compensation.

    Contact your Vickers representative foradditional information on the application

    and ordering of relief valves.Installation and Start-up

    The installation of PVH pumps must be inaccord with the data on pages 14 and 23.

    Before the pump is started, fill the casethrough the uppermost drain port withhydraulic fluid of the type to be used.Thecase drain line must be connecteddirectly to the reservoir and terminatebelow the oil level. If the pump has thevertical-mount option, attach a secondarydrain line as noted on page 25.

    Maximum continuous pressure at thecase drain port must not exceed 0,5 bar(7 psi). For multiple pump arrangementsthat include non-PVH sections, therequirements of the non-PVH units mustbe considered.