VHL2 LM-79-08 Test Report
Transcript of VHL2 LM-79-08 Test Report
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 2 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
March 25, 2013
Test performed by:
Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 [email protected]
INDEPENDENT TEST LABORATORY REPORT No. 31606
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 3 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Summary of Key Test Results: Model# VHL2F67219540USVY10I Manufacturer Howard Industries, Inc. LSI Test# T31606 Date of Test March 11th, 2013
Parameter Measured Result
Luminous Flux 17850 Lumens
Input Power 219.0 Watts
Efficacy 81.5 Lumens per Watt
C.C.T. 3903
C.R.I. 84.8
Beam Angle 104.6
Stabilization Time 120 minutes
The above results are recorded / derived from measurments in accordance with LM79-08
Notes: Tested in field application orientation.
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 4 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Table of Contents Test Results ............................................................................................................................................................................. 5
Spectral Flux and Chromaticity Diagram ............................................................................................................................. 6
Zonal Lumens Summary ...................................................................................................................................................... 6
Candela Plots ...................................................................................................................................................................... 7
Canedle Power Data ............................................................................................................................................................ 8
Lighting Sciences, Inc. Testing Information ........................................................................................................................... 9
Equipment List ..................................................................................................................................................................... 10
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 5 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Test Results – The following results were obtained after stabilization of the sample in accordance with the requirements set forth in section 5.0 of IES LM79-2008. Stability is achieved when the variation of 3 readings of light output and electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.
Photometric Results
VHL2F67219540USVY10I
Integrating Sphere Goniophotometer
Total Luminous Flux (Lumens) 17850 17039
Luminous Efficacy (Lumens / Watt) 81.5 76.4
Total Radiant Flux (Watts) 53.429 -
Correlated Color Temperature (CCT) 3903 -
Color Rendering Index (CRI - Ra) 84.8 -
Rg Value 23.3 -
Chromaticity (Chroma x / Chroma y) 0.387 / 0.3875 -
Chromaticity (Chroma u / Chroma v) 0.2252 / 0.3381 -
Chromaticity (Chroma u’ / Chroma v’) 0.2252 / 0.5072 -
Duv Value 0.0029 -
Expanded Uncertainty (k=2) (Percent) 2.1 2.8
Electrical Results
VHL2F67219540USVY10I
Integrating Sphere Goniophotometer
Input Power (Watts) (120/277V) 224.6 / 219.0 223.0
Input Voltage (Volts AC) (120/277V) 120.0 / 277.0 120
Input Current (Amps) (120/277V) 1.881 / .881 1.871
Power Factor (120/277V) 99.5 / 89.7 99.3
Input Frequency (Hertz) 60.0 60.0
A-THD (Current %) (120/277V) 6.56 / 17.89 % N/A
Additional Parameters
VHL2F67219540USVY10I
Integrating Sphere Goniophotometer
Stabilization Time (Light and Power) 120 120
Test Geometry Configuration 4π Type C
Spectroradiometer Labsphere LMS-760 Lighting Sciences 6000
Ambient Temperature 25.0 25.0
ISTMT (In-Situ Temperature Measurement) Not Tested
Spacing Criteria N/A
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 6 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Spectral Flux and Chrmaticity Diagram –
Spectral response of the Radiant Flux
(380 to 780nm)
Tristimulus values
x/ y = 0.3870 / 0.3875
Zonal Lumens Summary – Zone Lumens % Luminaire
0-30 4642 27.24
0-40 7497 44.00
0-60 12813 75.20
0-90 16444 96.51
40-90 8947 52.51
60-90 3631 21.31
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 7 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
90-180 595 3.49
0-180 17039 100.00
Test Results – Candela Plots The following images show the IsoFootcandle, Isocandela, and Zonal Distribution Plots respectively.
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 8 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 9 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Test Results –Candle Power Data The following table shows the Candela measurements from the ies file completed by the ganiophotometer.
Maximum candela = 6069.5 located at horizontal : 67.5⁰, Vertical : 2.5⁰
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 10 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
Lighting Sciences, Inc. (LSI) Testing Information The following information was taken directly from the LSI Lab Report:
INDEPENDENT TEST LABORATORY REPORT No. 31606A HOWARD INDUSTRIES INC - VAPOR TIGHT LUMINAIRE,CAT# VHL2F67219540USVY10I
WITH WHITE INTERIOR AND FROSTED PLASTIC DROP LENS 672 LEDS. LUMINAIRE OUTPUT = 17039 LM
LUMINAIRE OPERATING AT 120 VAC AND 223 WATTS LUMINOUS OPENING SIDE VIEW.
All testing was conducted in accordance with LM-79-08,
Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the
Illuminating Engineering Society of North America (IESNA).
The condition of the item tested was new. Stabilization time before testing meets the stabilization requirements
of LM-79-08.
The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series
6000 Type C Moving Mirror Goniophotometer
The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated
and traceable to the U.S. National Institute of Standards and Technology.
The test results (colorimetric and luminous flux) were obtained by using a Labsphere Model LMS-760 Integrating Sphere.
4π geometry was used. Correction factors were applied for self-absorption.
The colorimetric & photometric reference standard used is an incandescent spectral flux standard lamp calibrated and
traceable to the U.S. National Institute of Standards and Technology.
Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was
25⁰ C ± 1⁰ C, measured using an Omega model DP460.
Calibration certificates are on file at the laboratories of Lighting Sciences Inc.
The results in this report apply to the test sample(s) mentioned in this report at the time of the testing period only and are
not to be used to indicate applicability to other similar products.
Report # 20130325JR-LM79
IESNA LM79-2008 TEST REPORT
Page 11 of 11 LSI_Test_Number_T31606 20130325JR-LM79 Confidential Report
LSI Equipment List:
Lighting Sciences, Inc. equipment - Description Manufacturer / Model #
Integrating Sphere Labsphere LMS-760
Goniophotometer Lighting Sciences series 6000
Power Analyzer Yokogawa WT210
Thermometer Omega DP460
All Calibration Data is on file at LSI.