IES LM-79-08 TEST REPORT Report... · 2020. 7. 29. · IES LM-79-08: Approved Method: Electrical &...
Transcript of IES LM-79-08 TEST REPORT Report... · 2020. 7. 29. · IES LM-79-08: Approved Method: Electrical &...
-
Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described
herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.
IES LM-79-08 MEASUREMENT AND TEST REPORT
For
Shenzhen OKT Lighting Co.,LTD NO.2076 Jincheng Rd, Shajing Town, Bao’an District, Shenzhen, China.
Test Model: TB2-DM-35U (3500K)
Report Type: Electrical and Photometric tests including: Luminous Flux,
Power Factor, Chromaticity, Luminous Intensity
Distribution, THD
Test Engineer: Hexy He
Report Number: RSZ171106501-10
Test Date: 2017-11-06 to 2017-11-08
Report Date: 2017-11-16
Reviewed By: Blake Zhang / EE Engineer
Prepared By:
Bay Area Compliance Laboratories Corp. (Dongguan).
No.69,Pulongcun ,Puxinhu Industrial Area, Tangxia , Dongguan, Guangdong, China. Tel: +86-0769-86858888
Fax:+86-0769-86858588
Accreditation: The IAS Accreditation Number TL-460.
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 2 of 16
1. Product Description
General Information:
One sample was received on 2017-11-06 and used for testing.
Model Tested: TB2-DM-35U (3500K)
Manufacturer: Shenzhen OKT Lighting Co.,LTD
Brand Name: OKT Lighting
Product Designation: Direct Linear Ambient Luminaires
Burning Time Before Test: 0hour(For New Products)
Driver Model: WP-DL60-40-A-0.28A
Rated Values:
Rated Voltage/Frequency: 100-277 V AC 60Hz
Rated Power: 10 W
Nominal CCT: 3500K
Nominal Lumen Output: 1300 Im
Length: 2ft
2. Standards Used
IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products
ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting
IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in IAS
accreditation scope)
3. Description of Test Equipment
Device Manufacture Model No Serial No Test Range Calibration
date
Calibration due
date
2.0m integrating
sphere EVERFINE R98 11010018 R98 2016-11-18 2017-11-18
spectroradiometer EVERFINE HAAS-2000 20140912 380-780nm 2016-11-18 2017-11-18
Digital Power
Meter EVERFINE PF2010A 1011004 600V/20A 2017-07-29 2018-07-29
Digital CC&CV
DC Power Supply EVERFINE WY305-V1 1101047 30V/5A 2017-07-07 2018-07-07
Rapid Recording
Photometer EVERFINE PHOTO-2000F 1007010 0.1lm—200klm 2016-11-18 2017-11-18
Standard Light
Source SENSING N/A LSD090808 N/A 2016-12-05 2017-12-05
Special zero-
voltage
synchronous
switching AC
EVERFINE DPS1010-YF 1011001T 0-150V, 0-
300V 2017-03-03 2018-03-03
AC POWER
SUPPLY EVERFINE VPS1030 PWM 1012017
0-150V, 0-300V
2017-03-03 2018-03-03
Digital CC&CV
DC Power Supply EVERFINE WY12010 1009009 30V/5A 2017-03-03 2018-03-03
Digital power
meter YOKOGAWA WT-210 91j926132
15/30/60/150/30
0/600 V 2017-03-03 2018-03-03
full-field speed
goniophotometer EVERFINE GO-R5000
YG108492N101
20001
1600mm,3000
W/10A 2017-03-09 2018-03-09
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 3 of 16
Device Manufacture Model No Serial No Test Range Calibration
date
Calibration due
date
Wireless Remote
Sensor N/A 433MHz N/A
0°C~50°C;-
20°C~60°C 2017-03-20 2018-03-20
Standard Light
Source EVERFINE D908 1012003 N/A 2016-12-17 2017-12-17
Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).
4. Test Method
Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.
Integrating Sphere System
The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement.
4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the light output (luminous flux) measurements is U=1.9% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=25K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.9(K=2), at the 95% confidence level.
The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.18% of rdg, Power U=0.46%) (K=2), at the 95% confidence level.
Goniophotometer System
The goniophotometer system is calibrated by standard light source before measurement.
Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree.
The uncertainty of the luminous intensity is U=2.82% (K=2), at the 95% confidence level.
Additional Test
The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.
The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.46%) (K=2), at the 95% confidence level.
Fidelity Index and Gamut Index Calculation
The Rf, Rg was calculated according to IES TM-30-15 by using calculation tools. The calculation was based on the measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only.
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 4 of 16
5. Test Result
[Integrating Sphere System]
Total operating time for integrating sphere test: 1.0 hour
Test orientation: Downward
Photometric and Electrical Measurement Result
Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm)
Efficacy (lm/W)
120.0 60 0.08253 9.847 0.9943 1257.7 127.72
Radiant Flux (W) CCT (K) Duv x y u' v'
3.828 3373 -0.00070 0.4119 0.3923 0.2393 0.5129
Color Rendering Index
Ra
83.4
R1 R2 R3 R4
83 94 95 79
R5 R6 R7 R8
83 91 82 61
R9 R10 R11 R12
11 84 78 67
R13 R14 R15
86 98 76
-20 0 20 40 60 80 100
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 5 of 16
Fidelity Index and Gamut Index
Fidelity Index Rf 81
Gamut Index Rg 93
Spectral Power Distribution Comparison
Plot of Rg versus Rf
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
380 430 480 530 580 630 680 730 780
SPD
(n
orm
aliz
ed
to
Y=1
00
)
l (nm)
Test source Reference source
60
70
80
90
100
110
120
130
140
50 60 70 80 90 100
Rg
Rf
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 6 of 16
Chroma Shift by Hue Rf by Hue
Color Vector Graphic
-20%
-15%
-10%
-5%
0%
5%
10%
15%
20%
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hue Bin
50
55
60
65
70
75
80
85
90
95
100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hue Bin
Refenerce Illuminat Test Source
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 7 of 16
Color Fidelity by CES Sample
0 20 40 60 80 100
CES01
CES03
CES05
CES07
CES09
CES11
CES13
CES15
CES17
CES19
CES21
CES23
CES25
CES27
CES29
CES31
CES33
CES35
CES37
CES39
CES41
CES43
CES45
CES47
CES49
CES51
CES53
CES55
CES57
CES59
CES61
CES63
CES65
CES67
CES69
CES71
CES73
CES75
CES77
CES79
CES81
CES83
CES85
CES87
CES89
CES91
CES93
CES95
CES97
CES99
Fidelity Index, Rf
Co
lor
Eval
uat
ion
Sam
ple
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 8 of 16
Relative Spectral Power Distribution
nm mW nm mW nm mW nm mW nm mW
380 3.221E-01 421 3.678E-01 462 1.661E+01 503 9.480E+00 544 1.529E+01
381 3.610E-01 422 4.231E-01 463 1.539E+01 504 9.753E+00 545 1.545E+01
382 2.888E-01 423 4.793E-01 464 1.431E+01 505 9.946E+00 546 1.557E+01
383 2.781E-01 424 5.411E-01 465 1.339E+01 506 1.019E+01 547 1.571E+01
384 2.421E-01 425 6.184E-01 466 1.272E+01 507 1.041E+01 548 1.584E+01
385 1.595E-01 426 6.902E-01 467 1.215E+01 508 1.059E+01 549 1.603E+01
386 1.306E-01 427 7.719E-01 468 1.181E+01 509 1.083E+01 550 1.615E+01
387 1.475E-01 428 8.787E-01 469 1.148E+01 510 1.103E+01 551 1.632E+01
388 1.391E-01 429 9.827E-01 470 1.125E+01 511 1.122E+01 552 1.650E+01
389 1.151E-01 430 1.114E+00 471 1.094E+01 512 1.137E+01 553 1.664E+01
390 1.465E-01 431 1.269E+00 472 1.064E+01 513 1.154E+01 554 1.682E+01
391 1.218E-01 432 1.423E+00 473 1.027E+01 514 1.170E+01 555 1.697E+01
392 1.036E-01 433 1.608E+00 474 9.877E+00 515 1.188E+01 556 1.717E+01
393 9.581E-02 434 1.804E+00 475 9.447E+00 516 1.203E+01 557 1.737E+01
394 9.451E-02 435 2.038E+00 476 8.921E+00 517 1.217E+01 558 1.756E+01
395 1.117E-01 436 2.293E+00 477 8.463E+00 518 1.232E+01 559 1.776E+01
396 9.851E-02 437 2.602E+00 478 8.024E+00 519 1.244E+01 560 1.796E+01
397 7.596E-02 438 2.935E+00 479 7.666E+00 520 1.261E+01 561 1.814E+01
398 8.653E-02 439 3.283E+00 480 7.329E+00 521 1.270E+01 562 1.833E+01
399 8.853E-02 440 3.701E+00 481 7.072E+00 522 1.285E+01 563 1.854E+01
400 8.326E-02 441 4.151E+00 482 6.847E+00 523 1.295E+01 564 1.876E+01
401 1.011E-01 442 4.650E+00 483 6.733E+00 524 1.308E+01 565 1.894E+01
402 9.705E-02 443 5.193E+00 484 6.697E+00 525 1.319E+01 566 1.913E+01
403 9.434E-02 444 5.828E+00 485 6.700E+00 526 1.332E+01 567 1.934E+01
404 8.505E-02 445 6.592E+00 486 6.743E+00 527 1.341E+01 568 1.957E+01
405 8.370E-02 446 7.427E+00 487 6.820E+00 528 1.351E+01 569 1.978E+01
406 9.100E-02 447 8.446E+00 488 6.918E+00 529 1.363E+01 570 1.995E+01
407 1.029E-01 448 9.582E+00 489 7.024E+00 530 1.370E+01 571 2.019E+01
408 1.062E-01 449 1.085E+01 490 7.143E+00 531 1.383E+01 572 2.041E+01
409 9.341E-02 450 1.231E+01 491 7.266E+00 532 1.391E+01 573 2.063E+01
410 1.077E-01 451 1.389E+01 492 7.388E+00 533 1.405E+01 574 2.076E+01
411 1.189E-01 452 1.547E+01 493 7.498E+00 534 1.417E+01 575 2.100E+01
412 1.272E-01 453 1.711E+01 494 7.664E+00 535 1.425E+01 576 2.118E+01
413 1.419E-01 454 1.842E+01 495 7.784E+00 536 1.435E+01 577 2.135E+01
414 1.585E-01 455 1.961E+01 496 7.948E+00 537 1.445E+01 578 2.161E+01
415 1.802E-01 456 2.036E+01 497 8.165E+00 538 1.456E+01 579 2.178E+01
416 1.906E-01 457 2.062E+01 498 8.368E+00 539 1.467E+01 580 2.196E+01
417 2.231E-01 458 2.050E+01 499 8.554E+00 540 1.479E+01 581 2.214E+01
418 2.490E-01 459 1.989E+01 500 8.766E+00 541 1.489E+01 582 2.233E+01
419 2.870E-01 460 1.902E+01 501 9.011E+00 542 1.503E+01 583 2.249E+01
420 3.242E-01 461 1.779E+01 502 9.253E+00 543 1.518E+01 584 2.267E+01
0.0
0.2
0.4
0.6
0.8
1.0
380 430 480 530 580 630 680 730 780
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 9 of 16
nm mW nm mW nm mW nm mW nm mW
585 2.281E+01 626 2.037E+01 667 8.827E+00 708 2.627E+00 749 7.616E-01
586 2.294E+01 627 2.009E+01 668 8.608E+00 709 2.557E+00 750 7.308E-01
587 2.307E+01 628 1.983E+01 669 8.404E+00 710 2.462E+00 751 7.131E-01
588 2.323E+01 629 1.958E+01 670 8.135E+00 711 2.399E+00 752 6.886E-01
589 2.339E+01 630 1.928E+01 671 7.936E+00 712 2.325E+00 753 6.717E-01
590 2.352E+01 631 1.899E+01 672 7.747E+00 713 2.238E+00 754 6.529E-01
591 2.359E+01 632 1.872E+01 673 7.522E+00 714 2.180E+00 755 6.331E-01
592 2.373E+01 633 1.843E+01 674 7.336E+00 715 2.124E+00 756 6.139E-01
593 2.380E+01 634 1.813E+01 675 7.103E+00 716 2.048E+00 757 5.945E-01
594 2.385E+01 635 1.782E+01 676 6.922E+00 717 1.994E+00 758 5.816E-01
595 2.393E+01 636 1.755E+01 677 6.720E+00 718 1.926E+00 759 5.639E-01
596 2.397E+01 637 1.723E+01 678 6.510E+00 719 1.866E+00 760 5.524E-01
597 2.401E+01 638 1.694E+01 679 6.341E+00 720 1.815E+00 761 5.372E-01
598 2.407E+01 639 1.663E+01 680 6.160E+00 721 1.759E+00 762 5.234E-01
599 2.406E+01 640 1.631E+01 681 5.978E+00 722 1.701E+00 763 5.050E-01
600 2.409E+01 641 1.602E+01 682 5.817E+00 723 1.649E+00 764 4.978E-01
601 2.408E+01 642 1.575E+01 683 5.619E+00 724 1.600E+00 765 4.943E-01
602 2.408E+01 643 1.545E+01 684 5.484E+00 725 1.544E+00 766 4.715E-01
603 2.403E+01 644 1.513E+01 685 5.321E+00 726 1.495E+00 767 4.559E-01
604 2.402E+01 645 1.486E+01 686 5.163E+00 727 1.461E+00 768 4.495E-01
605 2.394E+01 646 1.455E+01 687 5.026E+00 728 1.420E+00 769 4.301E-01
606 2.392E+01 647 1.426E+01 688 4.865E+00 729 1.367E+00 770 4.271E-01
607 2.385E+01 648 1.395E+01 689 4.732E+00 730 1.331E+00 771 4.195E-01
608 2.372E+01 649 1.364E+01 690 4.582E+00 731 1.290E+00 772 4.028E-01
609 2.366E+01 650 1.334E+01 691 4.450E+00 732 1.251E+00 773 3.943E-01
610 2.352E+01 651 1.306E+01 692 4.319E+00 733 1.207E+00 774 3.837E-01
611 2.343E+01 652 1.278E+01 693 4.201E+00 734 1.174E+00 775 3.750E-01
612 2.328E+01 653 1.246E+01 694 4.065E+00 735 1.146E+00 776 3.660E-01
613 2.317E+01 654 1.222E+01 695 3.948E+00 736 1.103E+00 777 3.591E-01
614 2.300E+01 655 1.191E+01 696 3.837E+00 737 1.068E+00 778 3.491E-01
615 2.285E+01 656 1.165E+01 697 3.686E+00 738 1.038E+00 779 3.430E-01
616 2.268E+01 657 1.137E+01 698 3.604E+00 739 1.003E+00 780 3.436E-01
617 2.246E+01 658 1.110E+01 699 3.478E+00 740 9.789E-01
618 2.225E+01 659 1.082E+01 700 3.376E+00 741 9.517E-01
619 2.208E+01 660 1.058E+01 701 3.271E+00 742 9.252E-01
620 2.190E+01 661 1.031E+01 702 3.176E+00 743 8.896E-01
621 2.162E+01 662 1.007E+01 703 3.071E+00 744 8.775E-01
622 2.138E+01 663 9.781E+00 704 2.975E+00 745 8.408E-01
623 2.119E+01 664 9.543E+00 705 2.880E+00 746 8.174E-01
624 2.093E+01 665 9.283E+00 706 2.802E+00 747 7.905E-01
625 2.062E+01 666 9.067E+00 707 2.707E+00 748 7.786E-01
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 10 of 16
CIE 1931 x y Chromaticity Diagram
7-Step Chromaticity Quadrangles
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.30
0.35
0.40
0.45
0.30 0.35 0.40 0.45 0.50 0.55
sample
7-STEP 2200K
7-STEP 2500K
7-STEP 2700K
7-STEP 3000K
7-STEP 3500K
7-STEP 4000K
7-STEP 4500K
7-STEP 5000K
7-STEP 5700K
7-STEP 6500K
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 11 of 16
[Goniophotometer System]
Total operating time for luminous intensity distribution: 1.0 hour
Test orientation: Downward
Electrical Measurement
Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor
120.0 60 0.0823 9.830 0.9955
Photometric Measurement
Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)
1259.25 128.10 385.9 1.28 1.35
Luminous Intensity Distribution
C0/180 C45/225 C90/270 C135/315 AVG.
Beam Angle (50% Imax): 115.1 118.9 119.4 118.5 118.0
Field Angle (10% Imax): 161.6 167.2 169.6 166.8 166.3
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 12 of 16
Luminous Intensity (cd) Distribution Data
C
0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ
0.0° 386 386 386 386 386 386 386 386
5.0° 383 384 384 385 385 385 385 385
10.0° 378 379 380 380 381 381 381 381
15.0° 370 371 372 372 372 373 374 374
20.0° 358 360 360 360 360 361 362 363
25.0° 344 346 345 344 345 346 348 349
30.0° 327 329 327 326 326 328 330 333
35.0° 307 309 307 305 305 307 310 313
40.0° 285 286 284 282 282 284 287 291
45.0° 260 261 258 257 257 258 263 267
50.0° 233 234 231 229 229 231 235 239
55.0° 204 204 202 200 200 202 206 210
60.0° 173 173 171 169 169 171 175 179
65.0° 140 140 138 137 137 139 142 146
70.0° 106 106 105 104 105 106 109 112
75.0° 72 72 72 72 73 74 76 77
80.0° 39 40 42 44 44 45 45 45
85.0° 14 17 21 24 25 24 22 19
90.0° 3 10 16 20 22 20 16 9
95.0° 3 9 16 20 21 20 15 9
100.0° 2 9 15 19 20 19 15 8
105.0° 2 9 15 19 20 18 14 8
110.0° 2 8 14 18 19 17 13 7
115.0° 2 8 13 17 18 16 12 6
120.0° 2 7 12 16 17 15 11 5
125.0° 2 7 11 14 15 14 11 4
130.0° 2 6 10 13 14 13 10 4
135.0° 2 5 9 12 13 12 9 3
140.0° 2 4 8 11 11 10 8 3
145.0° 2 4 7 9 10 9 6 3
150.0° 2 3 6 8 8 8 5 2
155.0° 2 2 5 6 7 6 4 1
160.0° 2 2 4 5 5 5 4 1
165.0° 2 1 2 4 4 4 2 1
170.0° 2 1 1 1 2 1 1 1
175.0° 2 1 1 1 1 1 1 1
180.0° 2 2 2 1 1 1 1 2
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 13 of 16
Luminous Intensity (cd) Distribution Data (cont.)
C
180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ
0.0° 386 386 386 386 386 386 386 386
5.0° 384 384 385 385 386 385 384 384
10.0° 380 381 383 385 386 384 382 379
15.0° 373 375 379 383 383 381 377 373
20.0° 362 366 372 376 377 374 370 363
25.0° 349 355 362 366 366 364 359 351
30.0° 332 340 348 352 352 349 345 336
35.0° 313 323 331 335 335 332 327 318
40.0° 292 303 311 315 315 312 307 298
45.0° 268 280 289 293 293 290 284 274
50.0° 241 255 264 268 268 265 259 248
55.0° 213 228 237 241 242 238 231 220
60.0° 182 198 208 212 213 209 202 190
65.0° 150 166 176 182 182 178 170 158
70.0° 116 132 144 150 151 146 138 124
75.0° 82 98 110 117 118 114 104 90
80.0° 48 64 77 85 86 81 71 57
85.0° 20 34 47 55 56 52 41 28
90.0° 4 13 24 31 32 29 21 11
95.0° 3 10 17 21 23 21 16 9
100.0° 2 9 16 21 22 21 16 9
105.0° 2 9 16 20 22 20 16 9
110.0° 2 9 15 20 21 19 15 9
115.0° 2 9 15 19 20 19 15 8
120.0° 2 8 14 18 19 18 14 8
125.0° 2 8 13 17 18 17 13 8
130.0° 2 7 13 16 17 16 12 7
135.0° 2 7 12 15 15 14 11 6
140.0° 2 6 11 13 14 13 10 6
145.0° 2 5 9 12 13 12 10 6
150.0° 2 5 8 10 11 10 9 5
155.0° 2 4 6 8 10 9 8 5
160.0° 2 4 5 7 8 8 7 5
165.0° 2 2 4 5 6 6 5 5
170.0° 1 2 3 4 5 5 5 4
175.0° 1 1 2 2 3 4 4 3
180.0° 2 2 2 2 1 1 1 1
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 14 of 16
Zonal Lumen Density Measurement
Deg Flux (lm) %
Deg Flux (lm) %
0-5 9.2 0.73 0-5 9.2 0.73
5-10 27.4 2.18 0-10 36.6 2.91
10-15 44.9 3.56 0-15 81.5 6.47
15-20 61.0 4.85 0-20 142.5 11.32
20-25 75.3 5.97 0-25 217.8 17.29
25-30 87.1 6.92 0-30 304.9 24.21
30-35 96.3 7.65 0-35 401.2 31.86
35-40 102.3 8.12 0-40 503.5 39.98
40-45 105.1 8.35 0-45 608.6 48.33
45-50 104.6 8.31 0-50 713.2 56.64
50-55 100.6 7.99 0-55 813.8 64.63
55-60 93.5 7.42 0-60 907.3 72.05
60-65 83.2 6.61 0-65 990.5 78.66
65-70 70.2 5.57 0-70 1060.7 84.23
70-75 55.1 4.38 0-75 1115.8 88.61
75-80 39.0 3.09 0-80 1154.7 91.70
80-85 23.6 1.87 0-85 1178.3 93.57
85-90 12.7 1.01 0-90 1191.0 94.58
90-95 8.5 0.68 0-95 1199.5 95.26
95-100 7.8 0.61 0-100 1207.3 95.87
100-105 7.4 0.59 0-105 1214.7 96.46
105-110 7.0 0.55 0-110 1221.6 97.01
110-115 6.4 0.51 0-115 1228.1 97.52
115-120 5.8 0.47 0-120 1233.9 97.99
120-125 5.2 0.41 0-125 1239.1 98.40
125-130 4.6 0.36 0-130 1243.7 98.76
130-135 3.9 0.31 0-135 1247.6 99.07
135-140 3.2 0.26 0-140 1250.8 99.33
140-145 2.6 0.21 0-145 1253.5 99.54
145-150 2.0 0.16 0-150 1255.5 99.70
150-155 1.5 0.12 0-155 1257.0 99.82
155-160 1.0 0.08 0-160 1258.0 99.90
160-165 0.7 0.06 0-165 1258.7 99.96
165-170 0.4 0.02 0-170 1259.1 99.98
170-175 0.2 0.02 0-175 1259.2 100.00
175-180 0.0 0.00 0-180 1259.3 100.00
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 15 of 16
[Additional Test]
Test Item Test Voltage (V) Frequency (Hz) Test Result
Power Factor: 100.0 60 0.9979
Total Harmonic Distortion: 100.0 60 3.80%
Total Harmonic Distortion: 120.0 60 4.76%
Total Harmonic Distortion: 277.0 60 8.72%
Power Factor: 277.0 60 0.938
6. Product Photo
-
Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China. The IAS Accreditation Number TL-460.
Report No. RSZ171106501-10 Page 16 of 16
7. Product Test orientation in the Goniophotometer
***********END OF REPORT***********
2017-11-21T15:38:29+0800Bay Area Compliance Laboratories Corp.(Dongguan)