Varius Application of Dynair Fans -...

10
Sl. No. 1 -Centrifugal Roof Fan -ventilation in residential, commercial and industrial buildings. -Can be used for kitchen Exhaust application since motor FC and FC-2V is out side the air flow path. - Max. allowable Temperature 80ºC 2 -Centrifugal Roof Fan -ventilation in residential, commercial and industrial buildings. - Max. allowable Temperature 60ºC FC-V and FCV-2V 3 -Centrifugal Roof Fan -ventilation of civil, commercial and industrial buildings -Max. allowable temperature 40ºC REA 4 -Centrifugal Roof Fan -ventilation of civil, commercial and industrial buildings -Max. allowable temperature 40ºC REV 5 -Axial Roof Fan -ventilation in for Large premises. -Max. allowable temperature 50 ºC -Can be used for air in take also by reversing the air flow. TA-CC Varius Application of Dynair Fans Fan Model Application 98

Transcript of Varius Application of Dynair Fans -...

Page 1: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.1 -Centrifugal Roof Fan

-ventilation in residential, commercial and industrial buildings.-Can be used for kitchen Exhaust application since motor

FC and FC-2V is out side the air flow path.- Max. allowable Temperature 80ºC

2 -Centrifugal Roof Fan-ventilation in residential, commercial and industrial buildings.- Max. allowable Temperature 60ºC

FC-V and FCV-2V

3 -Centrifugal Roof Fan-ventilation of civil, commercial and industrial buildings-Max. allowable temperature 40ºC

REA

4 -Centrifugal Roof Fan-ventilation of civil, commercial and industrial buildings-Max. allowable temperature 40ºC

REV

5 -Axial Roof Fan-ventilation in for Large premises.-Max. allowable temperature 50 ºC-Can be used for air in take also by reversing the air flow.

TA-CC

Varius Application of Dynair Fans

Fan Model Application

98

Page 2: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

6 -Axial Roof Fan-For Extraction of large air volume.-Can be used with CC-HT fans for the smoke spill application.-Available in 800 mm - 1400 mm dia sizes.

TAV7 -Plate mounted axial fans

-Suitable for the ventilation, with wall or panel, in residential, commercial and industrial buildings.-Operating Temerature range -10ºC to +50ºC

QC8 -Compact Axial Fan

-Suitable for the ventilation, with wall or panel, in residential, commercial and industrial buildings.-Operating Temerature range -10ºC to +50ºC

COMPACT9 -Small Capacity Axial Fan

-Wall or panel mounted fans for vaentilation of premises, offices, laboratories, shops etc.-Operating temperature range -10ºC to +40ºC

BASIC10 -Ring Axial Fan

-ventilation in residential, commercial and industrial buildings.-They are designed for clean air in the temperature range -10°C +50°C.

AC/A & AC/B -AC-A is having inlet cone at one side and AC-B is having inlet cone on both side.-Inlet cone reduces the noise and increases thr efficiency.

99

Page 3: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

11 -Duct Axial Fan-CC series are used for ducted installations requiring large airflow with relatively low pressure drop.-Ventilation and cooling systems in industrial, naval, commercial, civil, energetic fields.

CC -Operating temperature range -10ºC to +50ºC12 -Belt Driven Duct Axial Fan

-CCT series is ideal for drying or painting plants, for ventilation (supply or exhaust) of air rich of smoke, dust and humidity and for all the applications where it is necessary to keep the motor not inside the air flow.-Operating temperature range -20ºC to +60ºC.

CCT13 -Portable Duct Axial Fan

-Application man coolers.-Operating temperature -10ºC to +50ºC

CCP14 -Biffurcated Duct Axial Fan

-Used to exhaust hot smoke, fumes, vapours, high humid and grease or oil laiden air.-Application: Kitchen exhaust, Laudry exhaust, paiting booth, furnace, cooling or evaporative tower etc.-Suitable to convey air up to 200°C in continuous service.

CCB -Construction of the casing will be in stainless steel of ANSI 304 grade as per our manufacturing standard.

100

Page 4: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

15 -Small size forward curved bladecentrifugal fans-Convey clean and not-dusty air and smoke, up to a maximum temperature of 80°C

DIC16 -Forward curved blade centrifugal fans

-They can convey clean air and light smoke with maximum temperature of 80 °C

AL17 -Radial blade centrifugal fans in aluminium

-To convey clean and not-abrasive dusty air and smoke (even with limited presence of chippings and fibers), up to a maximum temperature of 80°C.

F18 -Backward curved blade centrifugal fans for clean air

-Suitable for conveying clean or slightly dusty air, up to a maximum temperature of 80°C.

SQ

101

Page 5: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

19 -Backward curved blade centrifugal fans-Main application in commercial and industrial plants of air-conditioning, ventilation, heating and filtering.-They can be used as well in industrial processing (baker ovens, spray booths, driers, boilers, silos, cooling systems, etc.).

PR-L -Can convey clean or slightly dusty air and smoke with max. temperature of 80°C in standard configuration and up to 300°C with specials constructions.-Ideal for kitchen exhaust application.

20 -Backward curved blade centrifugal fans for dusty air-Main application in commercial and industrial plants of air-conditioning, ventilation, heating and filtering.-They can also be used as part of manufacturing process (wood industry, chemical industry, mills, mines, foundries, etc.).

PS-L -They can convey very dusty (not abrasive) air and smoke, with max. temperature of 80°C in the standard configuration and up to 300°C with specials constructions.

21 -Backward curved blade centrifugal fans for dusty air-Principal application in the industrial plants of pneumatic transport, suction and filtering in foundries, cement factories, mines, marble, ceramics and glass factories, furnaces, etc.-They can convey clean or slightly dusty air and smoke, with max. temperature of 80°C in the standard

PV-L configuration and up to 300°C with specials constructions.

102

Page 6: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

22 -Super-silent acoustic cabinet fans-Fans are suitable for being installed in small exhausting plants, where limited dimensions and easy installation are also required.-They must be installed only in horizontal position.-Maximum allowable temperature 40ºC.

SS-BOX23 -Rectangular duct centrifugal in-line fans

-Best suited fans for induct application.-The max. allowable temperature 50ºC

AxB24 -Slim-line acoustic cabinet fans

-The ultra-slim shape of these fans make them ideal for false ceiling installation in houses, offi -ces, public premise etc.-They are suitable to convey clean air up to a maximum temperature to 60°C.

MINI-BOX25 -Direct drive double inlet box fans

-Ventilation for varius application like apartments, houses, bar, restaurants, gymnasium, offices etc., since they have low nise level.

BOX-D26 -Duty and “stand by” box fans

-The twin fans are designed for installations where it is mandatory to guarantee an uninterrupted air exhaust/intake, even in case of failure.

TW-R/D 103

Page 7: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

27 -Direct drive double inlet fans-The blowers of the DA series are suitable for ventilation, conditioning, fi ltering, heating. They can treat clean air with max. temperature of 40°C.

DA28 -Belt driven double inlet box fans

-Ventilation for varius application like apartments, houses, bar, restaurants, gymnasium, offices etc., since they have low nise level.

BOX-T29 -Active carbon filtering units

-Application include air filtering and removal of smells. It is ideal for commercial enviorments and industrial plants where noise and bad smell is a problem.

BOX-CA30 -Round duct backward bladed centrifugal fans

-The fans are suitable in plants of ventilation and air conditioning, fi ltering and heating. They can only handle clean air up to the maximum temperature of 80°C.

DA-T31 -Centrifugal fans in plastic material

-The fan is particularly designed for conveying corrosive vapours and smokes, also with high humidity level and with maximum fl uid temperature of 60°C.

PR-AC

104

Page 8: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

32 -Small size centrifugal fans in stainless steel-The centrifugal fans of the DIC series are designed for conveyance of corrosive smoke, up to a maximum temperature of 80°C.

DIC-INOX33 -Duct Axial Fan F400 - F300 - F200

(certified according to EN 12101-03)-Application smoke spill.

CC-HT34 -Roof terminal for duct axial fans FOR FANS

CC-HT F400 - F300 - F200 (certifi ed according to EN 12101-03)-Application: smoke spill roof exhaust.

TAV-HT35 -Centrifugal roof fan 400°C /2h TESTED

-Application: Smoke spill roof exhaust.

FC-HT36 -Backward curved centrifugal fans 400°C /2h tested

-Smoke spill application, can used for kitchen exhaust application.

SQ-HT

105

Page 9: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

33These range is used for ventilation of haxardous or explosive area where the presence of combustible or inflamable gasses are there and atmospheric conditions where combustion rapidly expands itself (explosion) after ignition.

-Duct Axial Fan.

CC ATEX

-Plate mounted axial fans

QC ATEX

-Small size forward curved blade centrifugal fans

DIC ATEX

-Forward bladed centrifugal fans

AL ATEX

-Roof centrifugal fan, single speed

FC / FC-V ATEX

ATEX RANGE

106

Page 10: Varius Application of Dynair Fans - transmiddleeast.comtransmiddleeast.com/Pictures/DYNAIR/DUBAI/Dynair... · -Fans are suitable for being installed in small exhausting ... -Application

Sl. No.

Varius Application of Dynair Fans

Fan Model Application

34-Axial Jet Fans / Impuse Jet Fans-Application: Car park and Tunel Ventilation system.-Fire Rating: F200 and F300.

CC-JD/JR

-Centrifugal Jet fans / Induction Jet Fans-Application: Car park.

IJF -Fire Rating: F200 and F300.

DUCTLESS VENTILATION SYSTEM

107