USER'S MANUAL DEGAUSSER DEG-15T
Page 1 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
IMPORTANT NOTICE
This handbook contains important advice for the safe handling with the device.
The degausser DEG-15T is an industrial device with defined handling procedures.
To avoid potential injuries while using this device we recommend wearing gloves.
Read this manual carefully and operate the device only after you read and
understood this manual completely.
Should you face a situation that you cannot solve by contacting this manual, turn
the device off immediately, disconnect the power plug and absent yourself from
the device.
Contact our technical support by phone +49 (0)7531-361119-99 or by email
Technical changes in the sense of progression are subject to change.
PLEASE NOTE:Do not disconnect the device from power while operating or during an active erasure process.
This can cause irreparable damages to the machine and is not covered by the warranty.
Magnetic mediums, which are not supposed to be erased should be kept in a minimum distance
of 0.5 meter from the device.
WARNING:To avoid the risks of an electric shock or other hazards no modifications must be made to the
device and the sealed covers must not be opened.
Only by the manufacturer authorized service personal is allowed to do so.
Opening covers, breaking seals or loosening of any screws will lead to the immediate loss of the
manufacturer's warranty and liability.
PERSONS WITH HEART PACEMAKERS OR OTHER MEDICAL DEVICES (SUCH AS, BUT NOT LIMITED
TO, HEARING AIDS, INSULIN PUMP, 24-HOUR HOLTER MONITOR) SHOULD KEEP A MINIMUM
DISTANCE OF 3 METERS TO THE DEVICE.
Page 2 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
Table of content
1. Introduction ..............................................................................................................................4
1.1 Usage agreement ....................................................................................................................................5
2. Product characteristics.............................................................................................................6
2.1.Outline........................................................................................................................................................6
2.2. Basic information..............................................................................................................................7-10
2.3. Technical specification ........................................................................................................................11
2.4. Safety information................................................................................................................................12
3. Operation the degausser........................................................................................................13
3.1. Getting started.................................................................................................................................13-15
3.2. Safety functions.....................................................................................................................................16
4. Notes........................................................................................................................................17
Page 3 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
1. Introduction
The degausser DEG-15T is an innovative device for the safe erasure of magnetic storage mediums,
especially 3,5“ half-space hard discs.
The degausser DEG-15T is made in Germany and contains only high quality components to
guarantee a secure erasure at any time and a continual operation.
For the erasure of magnetic media a very strong electromagnetic field is necessary which the
DEG-15T produces in its enclosure. Under certain circumstances electromagnetic fields can be
hazardous for humans, therefore the DEG-15T is equipped with a wide-ranging security system.
The security system consists of two independent control systems which monitor operation and
each other continuously. Should either one of the systems malfunction the degausser switches
automatically into the protection mode and shuts the degausser down until normal operating
conditions are restored. If an error is not solvable a corresponding message on the display will
appear. If such a case should ever occur please contact our support.
The DEG-15T contains technically conditioned some parts that are subject to normal wear. Those
parts should be checked on a regular basis and be replaced if necessary. A service check should
be done no later than when a self-indication is issued. With that system the safety and function
of the degausser with its complete effect is ensured.
This replacement must be done only by authorized service personal, otherwise danger of life is given.
This „service“ is normally displayed by the degausser automatically according to the number of
operating hours and/or erasing procedures. In case of further operations without accomplishing the
maintenance work, it switches into the protection mode. In that case no erasing procedure can be run
to ensure a safe erasing procedure and to prevent possible hazards for the user.
Page 4 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
1. 1. Usage Agreement
By activating/using the degausser you agree to the terms listed below .
§1 Intellectual property
The DEG-15T contains software and electronic circuits (hardware) which are intellectual property of
Datafield Deutschland GmbH (in the following referred to as Datafield). This software, hardware and the
manual may not be copied, reproduced, duplicated, distributed or the like. Slight modifications and/or
their copies, duplications, distributions or the like which are derivated from the Datafield software /
hardware are not permitted. This includes even reverse engineering. Any offense against this term will be
brought into court and will be prosecuted penological as well as by civil law.
§2 Modifications to the degausser
Any modification that will be done to the DEG-15T need Datafields's explicit written approval. For further
information see §3.
§3 Breaking any seal
The device is secured against modifications and opening by visible and invisible safeguards. They act as a
safety for the user and the device. The unauthorized opening of the device will destroy those seals and
any warranty will be void automatically. Do not remove any screws of the device.
§4 Liability
Datafield is only liable for reckless faults in the production of the device. Datafield explicitly excludes any
liability for incorrect operation or malfunction due to absence of maintenance/service.
§5 Warranty
The warranty for this product lasts 12 month. In this time period all repairs which represent a material
defect are free of charge. Excluded from any warranty are wear and tear parts such as switches, relays /
electric contactors, motors and similar components. Defects caused by operating errors or poor
maintenance are not covered by this warranty. Before the device is sent back, the manufacturer has to be
contacted. Send -in devices which have a defect that are not covered by the warranty will be repaired and
charged after the cost estimates and after consulting the customer. In this case transportation and
checking will be billed to the customer. Devices send in freight collect are not accepted.
§6 Usage
The device is only intended for the industrial use. Private or other use for which the device is not intended
leads automatically that all liability and warranty claims against Blancco and the manufacturer are void.
§7 Salvatorius clause
If any of the clauses in this agreement are void or not executable or getting void after or not executable
after the sale will the rest of the use agreement and use conditions stay active. Instead of the void or not
executable clause, the clause that comes closest in terms of economic purpose will be in place. The prior
terms are also valid if any of the use agreements or use conditions are incomplete.
Konstanz(Germany) 29.12.2008. Competent court of jurisdiction Konstanz, Germany.
Page 5 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
2. Product Characteristics
2.1. Outline
A) Display
B) DokuKit extension port(only for DokuKit Basic or Pro)
D) Remote control (not shown in picture)
F) Operating and control unit
G) Front hatch
H) Power port
I) Cooling fan
Page 6 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
G
BH
I
F
A
USER'S MANUAL DEGAUSSER DEG-15T
2.2 . Basic information
A) Display
Pic. 1: Menu selection „Degaussing“
The display shows all relevant information that are necessary for operating the degausser and
enables you to retrieve further information about the device. You can find further information
about the display under “Operating and control unit”.
B) DokuKit extension port
Pic.2: DokuKit port. left 4P ( 2008) - right USB ( 2009 and younger)
In order to use the software “DokuKit” PRO or BASIC you have to connect the degausser to a PC.
From 2009 on there will be only one USB port at the operating unit. Connect the USB port with
your PC and install the provided driver when asked to do so by your operating system. More
information about the installation and usage of DokuKit can be found in the DokuSoft manual.
Degausser that are build prior to 2009 have a second 4P port which has to be connected to the
PC using the provided cable.
Degausser from 2009 on don't have this additional port.
Page 7 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
D) Remote control
With the remote control you can start the erasure process from a distance up to 5 meters. To do
so just push the upper button on the remote control and wait for the erasure process to start.
Should there be a malfunction the remote control can be deactivated in the degausser's control
unit. For more information see part “F) Operating and control unit”.
Should the remote control stop working please replace as a first step the batteries. Open the flap
on the back of the remote and replace the old batterie with a new one of the same type.
E) Cooling fan
The cooling fan grille may not be covered by anything at any time, otherwise the reliable rebuff
of heat is not guaranteed. Objects may not be inserted into the grille.
Page 8 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
F) Operating and control unit (Functions in the “Degaussing” mode)
F4 F6 F8
F1 F3 F2 F5 F7
F1 – Display
With the graphic display you can control the functions of the device as well as manually check
the intensity of the magnetic field during the erasure process.
F2 – Turn-switch
The turn-switch can be turned clockwise as well as counterclockwise to choose a menu item.
Push the turn-switch gently to open the submenu.
To leave the submenu choose “Back” to get back to the main menu. While in the menu item
“Degaussing” a gently push is enough to get directly to the main menu.
F3 – Operation light & warning light (red)
This light indicates a current erasure process. A blinking light in combination with the acoustic
warn signal indicates an error. The lamp may light up during normal operation.
F4 – Success & ready light (green)
The green light indicates the end of a successful erasure process and at the same time signals
the condition “ready” as soon as the front hatch is properly closed. A blinking light in
combination with the DokuKit indicates the end of the erasure process and that the user can
now save the report on the PC.
F5 – Start switch (red)
Starts the erasure process directly on the device without the remote control. The erasure process
will start 30 seconds after pushing the button (security level “normal”), giving the user enough
time to reach the safety clearance.
F6 – Front hatch unlocking (green)
The green button unlocks the front hatch for a couple of seconds. During an ongoing erasure
process the button is nonworking.
Page 9 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
F7 – Power Port (see section H)
F8 – DokuKit-plug (see section B)
G) Front hatch
Unlock the front hatch by pressing the green opening button (F6) while in the “Degaussing”
menu. Pull the hatch open and insert the hard drive in the carrier. Please note that you may only
insert a 3.5 inch half-spaced hard drive as bigger hard drives can cause serious damage on the
degausser and are not covered by the warranty. (For further details regarding erasure-able hard
drives see appendix A).
For safety reasons the front hatch is locked during an active erasure process. When the the green
success light glows permanently the front hatch can be opened as mentioned above. Prior to the
erasure process the hatch must be closed, otherwise a operating error will be assumed and the
erasure process will not start.
Never try to open the hatch by force as this may cause damage to the degausser. Wait till the
front hatch is hearable unlocked after you pressed the green button.
Opening the hatch by force or using a modified hatch can cause injuries by the moving hard
drive carrier.
H) Power plug / Power Port
This plug serves as reception for the supplied power cord and simultaneously to separate the
device from the power grid. The device may not be separated from the power grid for a longer
time period. Rather put the degausser in the standby mode by using the menu item “Standby”. In
the standby mode only the relevant operating data are monitored and therefore the power
consumption is reduced.
I) Cooler unit
The cooler unit contains several fans and heat conductors. At no time put fingers or other
objects in the front fan or other openings. This can cause malfunction, failure and/or injuries.
Furthermore can penetrating materials cause short circuits which may damage the device or
cause fire.
Page 10 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
2.3. Technical Specifications
1) Environmental Conditions (Must be maintained implicitly!)
Humidity : 35 % - 75 % relative humidity (not condensing )
Ambient temperature: 5 - 28°C
Impact resistance: <0,3G
Max. operation altitude: up to 1000m above sea level
2) Power Specifications
Rated current: 3000W (13A/230V)
Operating voltage: 225-235V / 50Hz
Averaged load current: 2790W (12,13A)
Standby current: 16W (0,28A)
Protection class: IP20 front cover dismantled
IP41 front cover mounted
Please note:
An additional external fusing is necessary: 16A / B characteristic
3) Dimensions and Weight
Weight: ca. 350kg
Height: 85cm
Depth: 90cm
Width: 56cm
With optional ErgoKit: Conformal load for double floors from 2000N / DIN 12825
4) Declaration of Conformity
This device is compliant to the following standards:
- DIN EN 55014-1 (Electromagnetic Compliance Part1– Interference Emission)
- DIN EN 60204-1 (Safety of Machines – Electrical Equipment of Machines Part 1 – General
Requirements)
For further information see appendix B
5) Exposure Area
The magnetic fields appearing in the exposure area of the operation personal have been
determent according to DIN EN 50413 and comply with the requirements of the German
accident prevention regulation BGV B11.
Page 11 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
2.4. Safety Informations
Possible risks of the magnetic field
The Degausser DEG-15T is most widely shielded against outward magnetic emission and
complies with the strict requirements of the German employer's liability insurance association's
accident prevention regulation BGV-B11. Please mind the following advices for your own safety
anyway:
Persons with implanted or not implanted electric devices (such as cardiac pacemaker, insulin
pumps, nerve stimulator and the like) must keep a minimum distance of 3m to the device
because even the weakest electromagnetic fields can cause a malfunction of the portable
device. This can result in severe injury or death.
For safety reasons please remove all metal items (such as rings, watches, bracelets and the like)
before using the degausser.
Do not put any magnetic stripe card (like ID-cards, debit cards or such) on the device or within a
range of 25cm of it.
Risks of usage
Do not operate the degausser at any time while under influence that could limit your awareness,
e.g. pharmaceuticals, alcohol and drugs. This can cause severe injuires
Do not open the device! It is a technical equipment and contains current-carrying parts inside.
Risk of fatal injury from electrical shock!
Danger of life!
Untrained personal must never handle the device. A safety/operation briefing is always
necessary, as well as an accurate consultation of the user manual, before handling the degausser.
Safety distance of magnetic mediums which are not intended for erasure
Magnetic mediums that are not intended to be erased in the degausser should kept away a
minimum distance of 1m. Especially magnetic tapes are very sensitive even for weak magnetic
fields.
Page 12 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
3. Use of the degausser
3.1. (Initial) Start Up / degaussing
Warning:
Let the degausser rest for at least 24 hours at its final installation site after
transportation or delivery to acclimate. Otherwise condensation could destroy
the device!
1) Power supply
Ensure that the power supply of the degausser is only connected to a voltage-range of 225-235V
with a 16A fuse (B characteristic). For safety reasons the power outlet should have a ground fault
circuit interrupter (GFCI) respectively should be controlled by a ground fault circuit interrupter
Connect the blue jack of the power cable with the corresponding blue socket (H) of the
degausser. Only then connect the degausser with the power outlet.
2) Suspending the standby mode
With connecting to the power supply the degausser is automatically in the standby mode. By
pressing the turn-switch softly the main menu will open.
3) Choosing the degaussing mode
When in the main menu choose the menu item “Degaussing” by turning the turn-switch. Push
the button softly to open the submenu. The submenu “Degaussing” will open and informs you
about the current status.
4) Opening the front hatch
On the front of the degausser you can find the large front hatch to insert the hard drives and
magnetic tapes you want to erase.
In order to open the hatch the green button (F6) has to be pressed to unlock the hatch. When
pressing the green button (F6) the front hatch will hearably unlock.
Open the hatch completely and insert the hard drive or magnetic tape.
Page 13 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
5) Inserting the erasure medium
After opening the hatch the erasure medium can be placed in the carrier, The carrier guarantees
the proper positioning of the storage medium. Please do only insert storage mediums which are
suited for the degausser (see appendix A). The height of hard drives inserted may only be 3,5
inch and may only have half-space frame size.
Never insert smaller, larger or higher hard drives (e.g. 2.5 inch or smaller) in the carrier!
To erase those hard drives please use a corresponding adapter, which can be acquired as
additional option from us to ensure the hard drives's proper positioning and avoid corrupt
erasures and damages to the degausser
Carrier ...with inserted hard drive (similar images)
6) Closing the front hatch
Close the front hatch by pushing it close until it locks hearably
7) Starting the erasure process
Start the erasure process either by using the remote control or the red start button (F5) on the
device. The degausser automatically locks the front hatch. The user has enough time (30
seconds) to reach the safety clearance.
The degausser performs the erasure process fully-automatic. No user interaction is necessary.
(Note: For cooling reasons several powerful fans are installed.)
Page 14 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
8) Control of the erasure process
A proper built magnetic field and therefore a reliable erasure can be identified on the magnetic
field gauge in the display (F1). Monitor this gauge during an ongoing erasure process. Bigger
deviations will be recognized by the degausser automatically. In such a case a corresponding
error message will be shown on the display followed by a acoustic warn signal.
If such a case should occur switch the device off and on (by disconnecting the power cord for 15
minutes (ONLY IN THE STANDBY MODE)) and restart the degaussing process. If nevertheless the
field intensity is still too weak please contact our support team.
The erasure process takes only 2.5 minutes. The erasure process's end is signaled by the blinking
of the green signal light (F4).
When using the additional option DokuKit the end of a erasure process is signaled by a success
message on the PC's monitor followed by erasure report for the particular hard drive.
9) Removal of the erasure medium
With the green signal light (F4) the end of the erasure process is indicated and the front hatch is
automatically unlocked by the degausser. Pull the hatch gently open and remove the data
medium. After a few seconds the front hatch will be locked again. It can be unlocked at any time
manually by pressing the green button (F6).
Note: When using the optional DokuKit the hatch only unlocks after the erasure report is filled
out and saved properly.
Page 15 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
3.2. Safety features
Underload
If the power consumption is smaller then usual the degausser switches into the safety mode due
to safety reasons. If this should happen repeatedly please contact our support team.
Overload
If the load is to high the degausser switches into hibernation until normal conditions prevail. This
can be recognized by a corresponding message in the display followed by a optical and acoustic
warn signal.
Excessive Temperature
To protect the degausser from excessive ambient temperature, it is equipped with an excessive
temperature shut-off. During this period the device is in the extended cooling mode. After
attaining normal heat conditions it can be used as usual.
Excessive temperature can also be caused by too fast consecutively erasures which is a normal
safety feature to protect the device from damage.
Field intensity
In case of derivations from the nominal field intensity, both positively and negatively, the
degausser recognizes this error automatically and stops the active erasing process. In this case
an according text message is shown in the display, followed by an acoustic and optical warning
signal.
Manipulation protection
The degausser recognized and records if someone tries to manipulate the device.
Redundancy
All safety-critical modules in the degausser are designed redundant. If a failure should occur and
a control-unit would fail to work a different control-unit will take over and protect the user from
malfunctions of the device.
Calibration
The degausser is calibrated ex factory and can be re-calibrated repeatedly during its life cycle. A
calibration by the user is not necessary. Differences from the target state and the actual state are
recognized automatically by the degausser that notifies the user to contact our support team.
Service-detection
Be If deviations from the manufacturing state are detected by the degausser the device
automatically asks for a service by showing a corresponding message in the display. This ensures
the continuous and safe operation of the degausser.
Page 16 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.
USER'S MANUAL DEGAUSSER DEG-15T
NOTES
Page 17 of 17 DEG-15T Manual.EN / R3 STD / Retrieved 2009-05-10© Copyright 2009 Datafield Deutschland GmbH. All rights reserved. Any unauthorized reproduction or publication is prohibited.