Updates for B&W Tek’s Mobile Molecular Spectroscopy September 24, 2013 B&W Tek, Inc Copyright 2013...

download Updates for B&W Tek’s Mobile Molecular Spectroscopy September 24, 2013 B&W Tek, Inc Copyright 2013 B&W Tek, Inc..

If you can't read please download the document

Transcript of Updates for B&W Tek’s Mobile Molecular Spectroscopy September 24, 2013 B&W Tek, Inc Copyright 2013...

  • Slide 1
  • Updates for B&W Teks Mobile Molecular Spectroscopy September 24, 2013 B&W Tek, Inc Copyright 2013 B&W Tek, Inc.www.bwtek.com1
  • Slide 2
  • Whats New New software release for NanoRam NOS/NID 4.20 Updated Manual Release Notes Installation and Upgrade instructions Additional Application Support Documents for NanoRam Copyright 2013 B&W Tek, Inc.www.bwtek.com2
  • Slide 3
  • NanoRam Software Highlights ver 4.20 Library transfer available for user-defined libraries Export of NanoRam results reports for integration with LIMS Removed Device Manager function in NOS simplify number of logins Update User interface for NanoRam single/batch Identification testing Remove Archive/Retrieve from NID- possibility of too many copies of data on PC Full details in Release Notes available along with software and updated manual from Distributor portal; Copyright 2013 B&W Tek, Inc.www.bwtek.com3
  • Slide 4
  • Library Transfer Synchronize library to NOS After synchronization libraries are resident in NID Software Choose samples of library to transfer (can only transfer user-defined libraries) Connect destination NanoRam to NID Transfer selected sample spectra to another NanoRam Unit Copyright 2013 B&W Tek, Inc.www.bwtek.com4
  • Slide 5
  • Copyright 2013 B&W Tek, Inc.www.bwtek.com5 1. Select Library 2. Select Sample Spectra 3. Transfer to a connected unit
  • Slide 6
  • Copyright 2013 B&W Tek, Inc.www.bwtek.com6
  • Slide 7
  • Library Transfer Screen in NID Copyright 2013 B&W Tek, Inc.www.bwtek.com7 Transferred library name prefixed with T Must synchronize from ->Device->Sync to complete the Library transfer process
  • Slide 8
  • Audit Trail after Synchronize NanoRam Copyright 2013 B&W Tek, Inc.www.bwtek.com8
  • Slide 9
  • Information on Transfer included as Note with Library Spectrum Copyright 2013 B&W Tek, Inc.www.bwtek.com9
  • Slide 10
  • LIMS Export At time of synchronizing NanoRam unit with NID All csv files sent to folder: ProgramLocation\BWTEK\NID\DataBase\NID Report Copyright 2013 B&W Tek, Inc.www.bwtek.com10
  • Slide 11
  • LIMS Export at later time Copyright 2013 B&W Tek, Inc.www.bwtek.com11
  • Slide 12
  • Example csv file from LIMS Export Copyright 2013 B&W Tek, Inc.www.bwtek.com12 First line indicates report type All the information that is included in pdf reports is included in the csv file
  • Slide 13
  • Updated Functions for ADMIN user Create calibration file (factory-set Polystyrene file can no longer be overwritten) Set system clock Set password expiration Define sample information fields Copyright 2013 B&W Tek, Inc.www.bwtek.com13
  • Slide 14
  • Setting of User-defined Fields Sample information fields now include 2 required: Run Name and Product Name and three optional user-defined fields Only the 2 required and any UDF will appear in testing interface Copyright 2013 B&W Tek, Inc.www.bwtek.com14 Customizable fields (by ADMIN user)
  • Slide 15
  • Updated Identification Mode Interface Removed terminology for Single Mode/Batch Mode Now define how many samples in a run; if = 1, this is the single mode When # of samples in run > 1, must enter Run Name Copyright 2013 B&W Tek, Inc.www.bwtek.com15
  • Slide 16
  • Multiple Samples in Run Define number of samples in Run (formerly Batch Mode) If a sample fails, user is asked if wants to run another sample: must enter Note if chooses Yes Continue Run until reach end Can Pause the Run, and return to it at a later time Copyright 2013 B&W Tek, Inc.www.bwtek.com16
  • Slide 17
  • Documentation and Services User Manuals Quick Start Manual for Operator-level users DQ/IQ/OQ/PQ Software release notes Identification Method Development Guidelines for the NanoRam Method Validation Report SOP for Operation of NanoRam IQ/OQ implementation and user training Method Development and Validation On-site Support Customized On-site training Copyright 2013 B&W Tek, Inc.www.bwtek.com17
  • Slide 18
  • THANK YOU ! www.bwtek.com18 Dr. Katherine A. Bakeev B&W Tek Inc. 19 Shea Way Newark, DE 19713, USA [email protected] Copyright 2013 B&W Tek, Inc.
  • Slide 19
  • Updates to Raman Price List Added prices for ST Japan Spectral Libraries Performance testing kit for iRaman instruments included with IQ/OQ and as standalone offering Copyright 2013 B&W Tek, Inc.www.bwtek.com19 Part NumberModel NumberDescription 810000710BAC151BVideo microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Dual wavelength available for 532, 785 or 1064nm laser excitation. 840000287NR-LVH Liquid vial holder adaptor for use with the BAC100 Lab Grade Raman Probe with shaft diameter of 9.5 mm. Compatible with 15mm- diameter vial. 6-pack of 15mm borosilicate glass vials included 810000738RSK001 Raman Sample Kit for BWTek Raman systems. Kit includes:Pouch for samples, Powder Cellulose, Powder Methocel MC, Powder Calcium carbonate, Powder Potassium carbonate, Liquid Glycerin, Liquid Ethanol, Liquid Methanol, Tablet Tylenol, Tablet Aspirin,. User instructions
  • Slide 20
  • Upcoming IQ/OQ certification October 8-10, 2013 at the B&W Tek corporate headquarters in Newark, DE, USA The third day is focusing on the training for our portable Raman systems, including the i-Raman Plus and i-Raman EX. November 6-7, 2013 in Hamburg, Germany Copyright 2013 B&W Tek, Inc.www.bwtek.com20