Uniflair pCOWeb Ethernet interface card

26
1 Uniflair Uniflair pCOWeb pCOWeb Ethernet interface Ethernet interface card card

description

Uniflair pCOWeb Ethernet interface card. Introduction. pCOWeb is an ethernet card that interfaces the latter with the emerging protocols (BACnet and SNMP), that are the emerging protocols in HVAC world, and are based on the Ethernet standard. Devices: where it can work. pCOc. pCO1. pCO2. - PowerPoint PPT Presentation

Transcript of Uniflair pCOWeb Ethernet interface card

Page 1: Uniflair  pCOWeb  Ethernet interface card

1

Uniflair Uniflair

pCOWeb pCOWeb Ethernet interface cardEthernet interface card

Page 2: Uniflair  pCOWeb  Ethernet interface card

2

pCOWeb is an ethernet card that interfaces the latter with the emerging protocols (BACnet and SNMP), that are the emerging protocols in HVAC world, and are based on the Ethernet standard.

Introduction

Page 3: Uniflair  pCOWeb  Ethernet interface card

3

Devices: where it can work

pCO2

pCO3

pCOc

upCOxs

pCO1

pCOb

Page 4: Uniflair  pCOWeb  Ethernet interface card

4

The board has a great memory capacity (8 MG flash, where 4 MG for the

user pages).

The operating system is Linux based

pCOWeb permits the connection to the following nets:

1. Local LAN nets o Internet: thanks to their web-server capacity, the user can download via FTP the HTML pages, and using a browser, can see/modify the variables sent from the pCO*.

2. SNMP nets v.1, v.2c, v.3

3. BACnet Ethernet ISO8802-2 over 8802-3; BACnet /IP; BACnet MS/TP

The parameters configuration can be done autmatically in case of DHCP servers

Features and Options

Page 5: Uniflair  pCOWeb  Ethernet interface card

5

Features and Options

It allows to access to the variables of the controller (pCOx) through acommon Ethernet LAN.

• Board features

• Power by pCO• ARM7 74MHZ• 16MB RAM, 8MB flash

• Linux 2.4.21

• Protocols:• HTTP (web pages 4MB)• SNMP (Simple Network Management Protocol)• BACnet (BACnet over IP and BACnet over Ethernet)• FTP server, FTP client

Page 6: Uniflair  pCOWeb  Ethernet interface card

6

Functions available

• WEB server: used to check or change the operating status of the pCO controller using a remote computer running, for example, Internet Explorer™ or Mozilla Firefox; dynamic web pages developed by the user can be added; supports CGI technology; supports protection for accessing web pages;

• Logger: pCOWeb can record the values of some of the pCO controller variables in a file on its non-volatile memory; the file can then be downloaded to a PC using Internet Explorer™;

• Graphs: the trends over time of the data saved with the Logger function can be viewed on graphs;

• pCOWeb can send e-mails when programmable events occur on the pCO controller (activation of alarms, exceeding of thresholds) or at set time intervals; a file in XML format can be attached containing the values of the variables;

• FTP PUSH: pCOWeb can send a file in XML format containing values of the variables to a suitably configured computer; the send operations can be programmed in the same way as for send the e-mail messages (upon event or at set times); the file is sent using the FTP protocol;

Page 7: Uniflair  pCOWeb  Ethernet interface card

7

• SNMPv1 & v2: to access pCOWeb from a computer using supervision software based on the SNMP protocol. pCOWeb can send programmable enterprise TRAP or INFORM packets for alarm notifications;

• BACnet Ethernet ISO8802-2 over 8802-3: to access the pCO controller using supervision software based on the BACnet Ethernet protocol;

• BACnet/IP (Addendum A/Annex J): for access using supervision software based on the BACnet/IP protocol;

• FTP server: used to copy data files or web pages from/to pCOWeb in a simple manner, using programs based on dragging icons from one window to another;

• DHCP: used to connect pCOWeb to a local network using the method of automatic addresses assignment by a central server, rather than statically setting the addresses on the individual devices; DHCP is active by default;

• Plugins: used to add additional applications developed by CAREL or by the user in script or compiled format;

• Firmware update: the pCOWeb firmware can be updated from a computer.

Functions available

Page 8: Uniflair  pCOWeb  Ethernet interface card

8

The ethernet line and theThe ethernet line and thepCOWeb InstallationpCOWeb Installation

Page 9: Uniflair  pCOWeb  Ethernet interface card

9

Example of network connection

Here an example of pCOWeb connection to a generic ethernet net

Computers connected in

the Ethernet company net

pCOWeb transforms the unit in a

PC with its own IP number

Thanks to the switch all the devices can be connected to the same net

Thanks to the internet connection,

and to the web-server function, pCOWeb

can answer inserting the IP address also from

a remote computer

Page 10: Uniflair  pCOWeb  Ethernet interface card

10

Buttons and leds

Push button: if pressed at the appropriate

moment: pCOWeb will use the

172.16.0.1 IP address

Status LED: during the correct functioning

it must blink fast Green-Off-Green-Off (it’s

transmitting

Status Ethernet: if green the

ethernet net is ok, if red it means

no phisical connection is availableIt’s the RJ45 ethernet connector.

For local connection to a PC, it’s

necessary a cross cable

Page 11: Uniflair  pCOWeb  Ethernet interface card

11

Leds meanings

Ethernet LED: displays the status of the physical network connection (Ethernet connection signals), regardless of whether the network parameters are correct; usually this must be green and flash when the data transits.

Status LED displays information on the communication status between pCOWeb andthe pCO, and must normally be green and flash around 3 times a second;

Page 12: Uniflair  pCOWeb  Ethernet interface card

12

pCO* installation

This is the Supervisory

System slot for the card

This is the MAC address, also

called “phisical address”, it’s a

48 bit code that identifies all

ethernet cards producted in the

world.

M: media

A: access

C: control

Page 13: Uniflair  pCOWeb  Ethernet interface card

13

First time installationConnecting pCOWeb directly to the pc

It’s mandatory to use a

CROSSOVER cable for the local

connection

The steps to be completed are as follows:

1.1. Configuration of the PCConfiguration of the PC for direct connection to pCOWeb.

2.2. Connection and start-up of Connection and start-up of pCOWebpCOWeb to checkcorrect installation.

3. Activation of the factory network settingsfactory network settings (button).4. AccessAccess to the pCOWeb from the PC.

Page 14: Uniflair  pCOWeb  Ethernet interface card

14

First time installationConnecting pCOWeb directly to the pc

Configuration of the PCConfiguration of the PC for direct connection to pCOWeb

In order to access inside the Ethernet cardmemory, it’s important to disable the firewallwhich is integrated inside the Windows

operatingsystem.

Page 15: Uniflair  pCOWeb  Ethernet interface card

15

First time installationConnecting pCOWeb directly to the pc

Configuration of the PCConfiguration of the PC for direct connection to pCOWeb

It’s important for a correct communication that both devices have the same aligned settings.

As the pCOWeb default settings can only be changed once the connection has been established with the PC, when first accessing the device the personal computer will need to be configured to adapt it to the pCOWeb default settings.

The personal computer must be set not to use the DHCP, but rather thefollowing IP address: 172.16.0.2. The Subnet mask field also needs to be set: 255.255.0.0the Gateway is not required

Page 16: Uniflair  pCOWeb  Ethernet interface card

16

First time installationConnecting pCOWeb directly to the pc

Configuration of the PCConfiguration of the PC for direct connection to pCOWeb

The proxy server must be disabled

1. Open the Windows “Control panel”.2. Double click “Internet options”; 3. Click “Connections”. Another window (Figure 3.d - right) will be displayed.4. Click “LAN settings…”5. Note down the settings.6. Disable the proxy server.7. Close the windows using the OK button.

Page 17: Uniflair  pCOWeb  Ethernet interface card

17

Connection and start-up of pCOWeb / activation factory settings

1. Connect pCOWeb to the Ethernet connector on the PC using a crossover cable

2. Immediately after reboot, as soon as the Status LED remains on steady GREEN, to activate the factory settings rather than the user settings, hold the button;

3. after around 20 seconds the Status LED, due to the button being pressed, will turn RED and flash slowly 3 times; the button must be released before then end of the 3 flashes;

4. once the red flashes have terminated, the Status LED will turn GREEN and, if the procedure has been performed correctly, immediately after the Status LED will confirm the pressing and release of the button by flashing quickly 3 times RED, and then will come on steady GREEN again for around one minute;

5. once the start-up phase has been completed, the Status LED will start flashing

First time installationConnecting pCOWeb directly to the pc

Page 18: Uniflair  pCOWeb  Ethernet interface card

18

First time installationConnecting pCOWeb directly to the pc

Pay attention:Pay attention:

Page 19: Uniflair  pCOWeb  Ethernet interface card

19

AccessAccess to the pCOWeb from the PC.

First time installationConnecting pCOWeb directly to the pc

On the PC open Internet Explorer; in the address field enter the following number, including the dots:

172.16.0.1then press ENTER.

IMPORTANT Before pressing ENTER wait for pCOWeb to complete the start-up phase (check that the Status LED is flashing normally), otherwise the required web pages will not be sent to the PC.The pCOWeb main page “index.html” will be displayed

Page 20: Uniflair  pCOWeb  Ethernet interface card

20

First time installationConnecting pCOWeb directly to the pc

This is the factory IP address, and the page is This is the factory IP address, and the page is thethedefault page already installed in the carddefault page already installed in the card

Page 21: Uniflair  pCOWeb  Ethernet interface card

21

First time installationConnecting pCOWeb directly to the pc

pCOWeb features an FTP server that is used to access the user memory and load or retrieve files, for example custom HTML pages, configuration files, log files. To use this function, the PC should be installed with an FTP client

Once having selected the OK button, the contents

of the user memory will be displayed (pathusr/local/root/flash/http/)

1. New remote browser 2. Information like shown on picture (in this case 172.16.0.1)

Page 22: Uniflair  pCOWeb  Ethernet interface card

22

First time installationConnecting pCOWeb directly to the pc

3. New local browser to display the hard disk content

Now the software is ready to transfer the HTML pages from the folder of your computer to The memory of the pCOWeb (4 Mb free).

Page 23: Uniflair  pCOWeb  Ethernet interface card

23

First time installationConnecting pCOWeb directly to the pc

Page 24: Uniflair  pCOWeb  Ethernet interface card

24

First time installationConnecting pCOWeb directly to the pc

Now the pCOWeb is ready to function with the Uniflair html customised pages

Page 25: Uniflair  pCOWeb  Ethernet interface card

25

First time installationConnecting pCOWeb directly to the pc

1. The serial speed on the user terminal must be 192002. The firewalls must be disabled3. The proxy server must be disabled 4. To access in the pCOWeb configuration: admin & fadmin5. To access via FTP: httpadmin & fhttpadmin6. The customised pages must be inserted inside: usr/local/root/flash/http7. To access with the computer to the pCOWeb you need to use a CROSS cable

Pay attention that if something is wrong, you shoud check:Pay attention that if something is wrong, you shoud check:

After Sales TeamAfter Sales Team

Page 26: Uniflair  pCOWeb  Ethernet interface card

26