U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24...
Transcript of U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24...
42017
2008
34013
1406
16 [.63] ANCHORS- BY INSTALLER
A
263 [10] TO GATE PANEL IN OPEN
POSITION
263 [10] TO GATE PANEL IN OPEN
POSITION
BBC C
H
D = NET GATE OPENING
1104 90
4
610 PILE24
301
1 DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com
STANDARD DIMENSIONS
DOUBLE DELTA GATEDescription:
Drawing No. Rev. Sheet:
5
-Project / Customer Name:
-
of
Finish: Date:90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110Fax: 1-204-284-1868
NOTE: DIMENSIONS ARE IN MILIMETERS. DIMENSIONS SHOWN IN [ ] ARE IN INCHES
MODELS 85/85 & 95/95 ONLY MODELS 85/85 & 95/95 ONLY
MODELS 85/85 & 95/95 ARE MEASURED TO THE OUTER EDGE OF OPTIONAL GATE REST PORTALNOTE:
GATE REST PORTALANCHORED TO ROADWAY SURFACE
GATE REST PORTAL
"U" DIMENSION IS THE MAXIMUM FOOTPRINT AFTER GATE INSTALLATION INCLUDING GATE PANEL TRAVEL
GATE CONTROLLER
*
OPTIONAL:
(MODELS 85/85 & 95/95 ONLY) (MODELS 85/85 & 95/95 ONLY)
OPTIONAL:CENTER PANEL CATCH SHOEGATE CONTROLLER
MODELS 95 & 120 ARE AVAILABLE IN 2000mm [78.7"] HEIGHTS ONLY
U max.REFERENCE OF GATE PANELIN OPEN POSITION
MEASURED TO TOP
GATE CONTROLLER
FOR LEVELING DETAILS
TO BOTTOM OF
OF PILE SEE SHEET 3
REFERENCE OF GATECONTROLLER
H
REFERENCE OF GATE PANELIN OPEN POSITION
**
Delta Model H A B C D U max.
30/30/150 1500 [59.1]30/30/200 2000 [78.7]30/30/250 2500 [98.4]40/40/150 1500 [59.1]40/40/200 2000 [78.7]40/40/250 2500 [98.4]50/50/150 1500 [59.1]50/50/200 2000 [78.7]50/50/250 2500 [98.4]60/60/150 1500 [59.1]60/60/200 2000 [78.7]60/60/250 2500 [98.4]70/70/150 1500 [59.1]70/70/200 2000 [78.7]70/70/250 2500 [98.4]85/85/150 1500 [59.1]85/85/200 2000 [78.7]85/85/250 2500 [98.4]95/95/200 2000 [78.7] 19120 [752.8] 2800 [110.2] 9560 [376.4] 18594 [732.0] 44040 [1733.9]
120/120/200 2000 [78.7] 24978 [983.4] 3726 [146.7] 24978 [983.4] 24452 [962.7] 55756 [2195.1]
12320 [485.0]
14920 [587.4]
2300 [90.6]
2300 [90.6]
2800 [110.2]
2800 [110.2]
9994 [393.5]
11794 [464.3]
6094 [239.9]
8194 [322.6]
1800 [70.1]6620 [260.6]
8720 [343.3]
10520 [414.2]
1800 [70.1]
17320 681.9]
14394 [566.7]
16794 [661.2]8660 [340.9]
17040 [670.9]
21240 [836.2]
25840 [1017.3]
29440 [1159.1]
35640 [1403.1]
40440 [1592.1]
510 REINFORCING STEEL20
D - NET GATE OPENING
1004
26310
26310
REFERENCE OF DELTA PORTAL
FACTOR, PILE DEPTH SHOULD 1000 [40] BELOW FROST LINE
MINIMUM PILE DEPTHPILE IS CAST 30 [1.2] BELOW1200
THE HIGHEST ELEVATIONALONG GATE TRAVEL - SEE
SHEET 3 FOR MORE DETAILSAREAS WHERE FROST IS A
61024
6 pcs. 15M VERTICALS WITH510 [20] RINGS SPACED
AT 300 [12] DOUBLE RINGAT TOP
DETAIL B - CONCRETE PILE
- CONTROLLER CONDUITDETAIL D
DELTA GATE POWER SUPPLY
25 [1] CONDUIT240 VAC SINGLE PHASE - 15 AMP
(MODELS 85 & 95 ONLY)
GATE CONTROLLER
POWER / COMMUNICATION WIRING STUB-UPLOCATIONS USE FLEX TYPE CONDUIT
PUBLIC SIDE
MIN.
MIN.
VEHICLE DETECTION LOOP
VEHICLE DETECTION LOOP
25 [1] CONDUIT
DELTA GATE POWER SUPPLY208 / 240 VAC SINGLE PHASE - 15 AMP
PHOTOEYE CONDUIT - SEE SHEET 5
CONDUIT FROM CONTROLLER STUB-UP LOCATION305 [12] FOOTING x 2 m [79] DEPTH c/w 19 [3/4]
(MODELS 85 & 95 ONLY)
PEDESTAL TO GATE CONTROLLER - BY OTHERS
PEDESTAL TO GATE CONTROLLER - BY OTHERS25mm [1] CONDUIT KEYPAD / CARD READER
PEDESTAL / BOLLARD LOCATIONS
GATE CONTROLLERDETECTION LOOPS TO DELTA2 - 25mm [1] CONDUIT VEHICLE
PERIODS OF TIME.
NOTE
WILL REMAIN IN THE OPEN POSITION FOR EXTENDED ONLY IF GATE SIZE EXCEEDS 8.5m [335] AND GATEREAR GATE REST PORTAL IS RECOMMENDED
:
:
EXTENDED PERIODS OF TIME.WILL REMAIN IN THE OPEN POSITION FOR ONLY IF GATE SIZE EXCEEDS 8.5m [335] AND GATEREAR GATE REST PORTAL IS RECOMMENDED
OTHERWISE SPECIFIED AT TIME OF ORDER.PEDESTALS AND BOLLARDS ARE SUPPLIED BY OTHERS UNLESS ARE SHOWN FOR REFERENCE ONLY.SUGGESTED PEDESTAL AND BOLLARDS LOCATIONS
NOTE
NOTE:
25mm [1] CONDUIT KEYPAD / CARD READER
GATE CONTROLLER
SECURE SIDE
[20]500
B CC BA
1574000
[39]1000
[8] BOLLARD200
305 [12] BOLLARD FOOTING
= "D" NET OPENING + 200 [8]
SEE LOOP SIZING CHART BELOW
CL
[47]1200 [36]915
[47]1200 [36]915
to
1829 [72] - TRUCKS [48] - CARS1219
4000
BOLLARD
157
1829 [72] - TRUCKS [48] - CARS1200
CL
8 BOLLARD200
610SEE DETAIL B
[24] DELTA GATE PILE
305 BOLLARD FOOTING12
U max.
2 5
Description:
:teehS.veR.oN gniwarD
of
:etaD:hsiniF
Project / Customer Name:
Fax: 1-204-284-1868
SUGGESTED LOOP AND PEDESTAL LOCATIONS
DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com
STANDARD DIMENSIONS
90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110
DOUBLE DELTA GATEDelta Model D - NET OPENING [ IN ] LW - LOOP WIDTH [ IN ]
30/30 6094 [240] 4572 [180]
40/40 9194 [323] 6401 [252]
50/50 9994 [394] 8230 [324]
60/60 11794 [464] 10058 [396]
70/70 14394 [567] 12802 [504]
85/85 16794 [661] 15240 [600]
95/95 18594 [732] 17069 [672]
120/120 24452 [962.7] 22869 [900]
A
130 [5"] MEASURED FROM TOP OF PILE.AREA ALONG GATE PANEL TRAVEL MUSTBE CLEAR OF OBSTRUCTIONS TO ALLOWPROPER OPERATION OF GATE.GROUND COVER SHOULD BE RESILIANTENOUGH TO ALLOW CLEARING OF MUD,ICE, SNOW OR DERIS BUILD UP.
BC
U max.
BELOW HIGHEST ELEVATIONCAST PILES 30 [1.2"]
ALONG GATE TRAVEL (U max)
B C
REMOVAL OF ANY MUD , ICE, SNOW OR
AREA ADJACENT TO GATE SHOULD BECLEAR OF OBSTRUCTIONS ALLOWING
DEBRIS BUILD UP THAT MAY OCCUR.
PILES MUST BE CAST LEVEL
DOUBLE DELTA SLIDE GATE
INSTALLATION NOTESDescription:
Drawing No. Rev. Sheet:
of
Finish: Date:
-
DOUBLE-DELTA-07-13-11 3 5
Project / Customer Name:
Web: www.wallaceintl.com
-
90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110Fax: 1-204-284-1868
REFERENCE OF GATE PANEL IN OPEN POSITION
*** IMPORTANT NOTE ***
REFERENCE OF GATE PANEL IN OPEN POSITION
SURFACE SHOULD BE SUITABLEFOR SECURING CENTER CATCHSHOE USING 16 [5/8"] ANCHORS
1506
4-2A
L
DETAIL 4-4 - OPTIONAL REAR REST SHOE
NOTE:
REAR GATE REST SHOE IS RECOMMENDED ONLY IF GATE SIZE IS EQUAL TO OR GREATER THAN 8.5M [335] AND THE GATEWILL REMAIN IN THE OPEN POSITION FOR EXTENDED PERIODS OF TIME
DETAIL 4-2B - MAIN BEAM ROLLER SET
MAIN BEAM ROLLER SET (X2)
CONTROLLER IS 90 [3.5]FROM GRADE
NOTE:
BOTTOM OF GATE
INCOMING POWER REQUIREMENTS, 240 VAC SINGLE PHASE, 15A
GATE CONTROLLER IS LOCATED ON THE SECURE SIDE OF GATE.
NOTES:
GATE FINISH:
- HOT DIPPED GALVANIZED FINISH FOR ALL STEEL COMPONENTS
- ALUMINUM GATE BEAMS - CLEAR ANODIZED FINISH
OPTIONAL:
POWDER COAT PAINT FINISH AVAILABLE - RAL COLOR NUMBER MUST BE SUPPLIED AT TIME OF ORDER.
36014
13340
50020
DETAIL 4-2A
4-2B
- CENTER CATCH SHOE DETAILSDETAIL 4-3
- GATE CONTROLLER DIMENSIONSDETAIL 4-1
- UPPER PANEL SUPPORT ROLLER
DETAIL 4-2 -PANEL ROLLERS
STANDARD / OPTIONAL COMPONENTS
Description:
:teehS.veR.oN gniwarD
of
:etaD:hsiniF
Project / Customer Name:
Fax: 1-204-284-1868
-
DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com 4 5
90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110
DOUBLE DELTA GATE
PANEL SUPPORT ROLLER (x4)
DETAIL 4-5A - HERECLES PANEL INFILL DETAIL 4-5B - ATLAS PANEL INFILL
SERRATED ALUMINUMANTI-CLIMB EDGE
245
502
PICKETS EXTEND THRU GATETOP BEAM AND ARE MITRE CUTAT A 45 ANGLE
1837
1506
CL
CENTER CATCH SHOE IS ANCHORED TO ROADWAY USING 16 [5/8] WEDGE ANCHORS. ROADWAY SURFACE MUSTBE OF SUITABLE QUALITY FOR THEINSTALLATION OF ANCHORS.
CLOF ROADWAY
33013
16400
10250
60024
13330
A
25 [1.0] SPARE
GATE CONTROLLER
13 [1/2"] FLEX TYPE PHOTOEYE CONDUIT
25 [1.0"] POWER CONDUIT
GATE CONTROLLER
25 [1.0"] COMMUNICATION CONDUIT
LEAVE 610 [24.0"] EXCESS FOR CONNECTIONS ABOVE GRADE.
ALL CONDUIT TO CONTROLLER LOCATION ARESTUBBED UP UNDER CONTROL ENCLOSURE.
ALL CONDUIT BELOW GRADE TO BE RIGID TYPE PVC
13340610
24
1707
CONDUIT LOCATION DETAIL
Description:
:teehS.veR.oN gniwarD
of
:etaD:hsiniF
Project / Customer Name:
Fax: 1-204-284-1868
-
-
DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com
-
55
90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110
DELTA GATE
CONTROLLER PORTAL PHOTOEYE CONDUITDETAIL A:
13 [1/2"] FLEX TYPE PHOTOEYE CONDUIT FROM GATE CONTROLLER TO PHOTOEYE MOUNTED ON PORTAL - BY GATE INSTALLERS GROUT FLEX CONDUIT IN PLACE AFTER INSTALLATION IS COMPLETE
A
GROUT LEVELING GAP AFTER INSTALLATION
914 [36] BELOW GRADE
ABOVE GRADE305 [12]
IS COMPLETE. (ALL PORTALS)
13 [1/2"] FLEX TYPE PHOTOEYE CONDUITSTUBBED INTO CENTER OF GATECATCH PORTAL - SEE DETAIL A ABOVENO TRANSITION FROM RIGID TO FLEXCONDUIT SHOULD BE DONE BELOWGRADE
SEE SHEET 2 FOR MORE INFORMATION ON CONDUIT REQUIREMENTS AND LOCATIONS