Type Series Booklet - KSB Pumps with Shaft Seal Thermal Oil/Hot Water Pumps Etabloc SYT/ Etaline SYT...
Transcript of Type Series Booklet - KSB Pumps with Shaft Seal Thermal Oil/Hot Water Pumps Etabloc SYT/ Etaline SYT...
Thermal Oil / Hot Water Pump
Etabloc SYT/ Etaline SYT
Type Series Booklet
Legal information/Copyright
Type Series Booklet Etabloc SYT/ Etaline SYT
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,edited or processed for any other purpose, nor otherwise transmitted, published or made available toa third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
© KSB Aktiengesellschaft, Frankenthal 02.02.2016
Contents
Centrifugal Pumps with Shaft Seal ...................................................................................................................4
Thermal Oil/Hot Water Pumps ....................................................................................................................................... 4
Etabloc SYT/ Etaline SYT ........................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data .................................................................................................................................................... 4
Designation .......................................................................................................................................................... 4
Further information on the designation ...................................................................................................... 4
Design details ....................................................................................................................................................... 4
Installation types ................................................................................................................................................. 5
Automation .......................................................................................................................................................... 6
Coating and preservation ................................................................................................................................... 6
Product benefits .................................................................................................................................................. 6
Acceptance tests / warranty ................................................................................................................................ 6
Overview of fluids handled ................................................................................................................................. 7
Pressure and temperature limits ......................................................................................................................... 7
Materials .............................................................................................................................................................. 7
Technical data ...................................................................................................................................................... 8
Etabloc SYT ..................................................................................................................................................... 8
Etaline SYT ..................................................................................................................................................... 8
Selection charts ................................................................................................................................................... 9
Etabloc SYT, n = 2900 rpm ............................................................................................................................. 9
Etabloc SYT, n = 1450 rpm ............................................................................................................................. 9
Etabloc SYT, n = 3500 rpm ........................................................................................................................... 10
Etabloc SYT, n = 1750 rpm ........................................................................................................................... 10
Etaline SYT, n = 2900 rpm .......................................................................................................................... 11
Etaline SYT, n = 1450 rpm .......................................................................................................................... 11
Etaline SYT, n = 3500 rpm .......................................................................................................................... 12
Etaline SYT, n = 1750 rpm .......................................................................................................................... 12
Dimensions ......................................................................................................................................................... 13
Etabloc SYT, 2-pole ...................................................................................................................................... 13
Etabloc SYT, 4-pole ...................................................................................................................................... 17
Etaline SYT, 2-pole ....................................................................................................................................... 20
Etaline SYT, 4-pole ....................................................................................................................................... 23
Connection types ............................................................................................................................................... 26
Flange design ..................................................................................................................................................... 27
Flange dimensions ............................................................................................................................................. 28
Scope of supply .................................................................................................................................................. 28
General assembly drawings .............................................................................................................................. 29
Etabloc SYT exploded view ......................................................................................................................... 29
Etaline SYT exploded view .......................................................................................................................... 30
Detailed designation (Etabloc) ......................................................................................................................... 31
Detailed designation (Etaline) .......................................................................................................................... 32
Contents
3
Centrifugal Pumps with Shaft Seal
Thermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT
Main applications
▪ Heat transfer systems
▪ Hot water circulation
Fluids handled
▪ Thermal oil
– Mineral
– Synthetic
▪ Hot water
Operating data
Etabloc SYT operating properties
Characteristic Value
50 Hz 60 HzFlow rate Q [m3/h] ≤ 280 ≤ 337Head H [m] ≤ 68 ≤ 99Fluid temperature Thermal oil T [°C] -30 to +350
Hot water T [°C] ≤ 180Operating pressure p [bar] ≤ 16
Etaline SYT operating properties
Characteristic Value
50 Hz 60 HzFlow rate Q [m3/h] ≤ 316 ≤ 228Head H [m] ≤ 69 ≤ 101Fluid temperature Thermal oil T [°C] -30 to +350
Hot water T [°C] ≤ 180Operating pressure p [bar] ≤ 16
Designation
Example: ETBY 050-032-160 SGXDB08D2
Designation key
Code DescriptionETBY Type series
ETBY Etabloc SYTETLY Etaline SYT
050 Nominal suction nozzle diameter [mm]032 Nominal discharge nozzle diameter [mm]160 Nominal impeller diameter [mm]S Casing material
S = nodular cast ironG Impeller material if different from casing
materialG = cast ironC = stainless steel
X Additional code X = special design
D Casing coverD = casing cover for SYT
B Sealing systemB = dead end
08 Seal code08 = AQ1VGG
D Pump set2 Shaft unit
2 = WS 25
Further information on the designation
(⇨ Page 31) (⇨ Page 32)
Design details
Design
▪ Volute casing pump
▪ Horizontal/vertical installation
▪ Back pull-out design
▪ Single-stage
Etabloc SYT:
▪ Ratings to EN 733
Pump casing
▪ Radially split volute casing
▪ Replaceable casing wear rings
Etabloc SYT:
▪ Volute casing with integrally cast pump feet
Etaline SYT:
▪ In-line design
Impeller type
▪ Closed radial impeller with multiply curved vanes
Shaft seal
▪ Reinforced single mechanical seal, installation dimensionsto EN 12756
Bearings
▪ Product-lubricated carbon plain bearing
▪ Grease-lubricated radial ball bearing in the motor housing
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
4 Etabloc SYT/ Etaline SYT
Static sealing elements
Between:
▪ Volute casing and discharge cover
▪ Discharge cover and bearing housing
▪ Bearing housing and seal cover
Always use original KSB spare parts for bearings, mechanicalseals and static sealing elements!
Drive
Standard design:
▪ KSB surface-cooled IEC frame three-phase current squirrel-cage motor
▪ 50 Hz winding, 230 V delta configuration ≤ 2.20 kW
▪ 50 Hz winding, 400 V star configuration ≤ 2.20 kW
▪ 50 Hz winding, 400 V delta configuration ≥ 3.00 kW
▪ 50 Hz winding, 690 V star configuration ≥ 3.00 kW
▪ 60 Hz winding, 460 V star configuration ≤ 2.60 kW
▪ 60 Hz winding, 460 V delta configuration ≥ 3.60 kW
▪ Type of construction: V1
▪ IP55 enclosure
▪ Mode of operation: continuous operation S1
▪ Thermal class F with temperature sensor, 3 PTC thermistors
▪ Efficiency class IE2 or IE3
or
▪ Surface-cooled KSB SuPremE motor, IEC-compatible,magnetless synchronous reluctance motor (PumpDriverequired)
▪ Motor mounting points in accordance with EN 50347
▪ Envelope dimensions in accordance with DIN V 42673(07-2011)
▪ Frequency 50/60 Hz (PumpDrive input)
▪ Voltage 380/480 V (PumpDrive input)
▪ Type of construction: V1
▪ IP55 enclosure
▪ Mode of operation: continuous operation S1
▪ Thermal class F with temperature sensor, 3 PTC thermistors
▪ Efficiency class IE4 in compliance with IEC/CD 60034-30 Ed.2
Explosion-proof version:
▪ KSB surface-cooled IEC frame three-phase current squirrel-cage motor
▪ 50 Hz winding, 230 V delta configuration ≤ 1.85 kW
▪ 50 Hz winding, 400 V star configuration ≤ 1.85 kW
▪ 50 Hz winding, 400 V delta configuration ≥ 2.50 kW
▪ 50 Hz winding, 690 V star configuration ≥ 2.50 kW
▪ Type of construction: V1
▪ Mode of operation: continuous operation S1
▪ IP55 enclosure
▪ Type of protection EExe ll
▪ Temperature class T3
Installation types
Horizontal installation, Etabloc SYT
Vertical installation, Etabloc SYT
Horizontal installation, Etaline SYT
Vertical installation, Etaline SYT
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 5
Automation
Automation options:
▪ PumpDrive (wall-mounted, cabinet-mounted)
Coating and preservation
▪ Coating and preservation to KSB standard
Product benefits
▪ Improved efficiency and NPSHreq by experimentally verifiedhydraulic design of impellers (vanes)
▪ Operating costs reduced by trimming the impellerdiameter to match the specified duty point
▪ Little wear, low vibration levels and excellent smoothrunning characteristics thanks to good suctionperformance and virtually cavitation-free operation acrossa wide operating range
▪ Casing sealed reliably – even in varying operatingconditions – by confined casing gasket
▪ Extended selection chart with additional pump sizes forsmall flow rates
▪ Easy to dismantle due to back pull-out design; no need toremove the pump casing from the piping
Acceptance tests / warranty
The following acceptance tests may be performed at asurcharge:
▪ Materials testing
– Test report 2.2
▪ Final inspection
– Inspection certificate 3.1 to EN 10204
▪ Hydraulic test
– The duty point of each pump is guaranteed accordingto ISO 9906/2B or ISO 9906/3B.
– NPSH test
▪ Other inspections/tests on request
Warranties
▪ Warranties are given within the scope of the valid deliveryconditions.
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
6 Etabloc SYT/ Etaline SYT
Overview of fluids handled
Table of fluids handled and associated material combinations ✘ = standard
Fluid handled Application limits1) Casing/impellermaterials
Shaft sealsingle mechanical seal
Nodular cast iron/grey cast iron
Nodular cast iron/stainless steel
AQ1VGG
SG SC Code 08
Hot water2) t ≤ +180 °C ✘ ✘p ≤ 16 bar
Thermal oil on mineral oil basis t ≤ -30 to +350 °C ✘ ✘p ≤ 16 bar
Thermal oil on synthetic basis, vapourpressure ≤ 1 bar at operatingtemperature3)
t ≤ -30 to +350 °C ✘ ✘p ≤ 16 bar
Pressure and temperature limits
Pressure and temperature limits
Material variant Fluid temperature Test pressure4)
[°C] [bar]S -30 to +350 ≤ 25
16
15
14
13
12
11
100 150 200 250 300 350
Pressure [bar]
Temperature [°C]50 100-30
Pressure limits and temperature limits: pump with flangesdrilled to EN 1092-2 or ASME B 16.1 Class 125.
Materials
Overview of available materials
Part No. (⇨ Page 29) Description Material variant102 Volute casing Nodular cast iron EN-GJS-400-15/ 536 GR 60-40-18161 Casing cover Nodular cast iron EN-GJS-400-15/ 536 GR 60-40-18210 Shaft Chrome steel 1.4021+QT800230 Impeller Grey cast iron EN-GJL-250/ A 48 CL 35B
Chrome steel 1.4408/ A 743 GR CF8M310 Plain bearing Carbon341 Drive lantern Grey cast iron EN-GJL-250/ A 48 CL 35B350 Bearing housing Nodular cast iron EN-GJS-400-15/ 536 GR 60-40-18411.10/.15 Sealing elements BU9593/ HDR502.01 Casing wear ring, suction side Grey cast iron EN-GJL-250/ CI502.02 Casing wear ring, discharge side Grey cast iron EN-GJL-250/ CI
1) The inlet pressure must not fall below atmospheric pressure.2) Low-salt or fully desalinated water to VdTÜV technical instruction leaflet / AGFW technical instruction leaflet
TCN 1466 (VdTÜV) 5/15 (AGFW), edition 02.893) For vapour pressures exceeding 1 bar use an Etanorm SYT pump.4) The casing components are checked for leakage by means of internal pressure tests to AN 1897/75-03D00 with water.
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 7
Part No. (⇨ Page 29) Description Material variant902 Studs 8.8/ 5.8903 Plug Steel920 Nut 8 + A2A/ 8 + B633 SC1 TP920 Impeller nut 8
A4/ AISI316
Technical data
Etabloc SYT
Technical data
Sizes Shaft unit Impeller Speed limit
Impeller outletwidth
Impeller inletdiameter
Impeller diameter Maximum Minimum
Maximum Minimum
[mm] [mm] [mm] [mm] [rpm] [rpm]040-025-160 WS_25 6,0 45,2 169 130 3500 800040-025-200 WS_25 6,0 45,2 209 160 3500 800050-032-125.1 WS_25 6,6 52,4 139 104 4300 800050-032-160.1 WS_25 5,7 52,7 170 136 4400 800050-032-200.1 WS_25 5,6 54,0 204 170 3800 800050-032-160 WS_25 8,5 60,6 174 136 3500 800050-032-200 WS_25 7,0 62,9 209 170 3700 800065-040-160 WS_25 13,0 70,0 174 128 4400 800065-040-200 WS_25 9,4 69,4 209 165 3700 800065-050-160 WS_25 16,9 86,9 174 128 4400 800065-050-200 WS_25 13,8 83,1 219 170 3500 800080-065-160 WS_25 21,0 92,0 174 132 3900 800080-065-200 WS_25 17,0 99,7 219 175 3500 800100-080-160 WS_25 31,6 124,0 174 138 3500 800
Etaline SYT
Technical data
Sizes Shaft unit Impeller Speed limit
Impeller outletwidth
Impeller inletdiameter
Impeller diameter Maximum Minimum
Maximum Minimum
[mm] [mm] [mm] [mm] [rpm] [rpm]032-032-160 WS_25 5,7 52,7 170 136 4400 800032-032-200 WS_25 5,6 54,0 204 170 3800 800040-040-160 WS_25 8,5 60,6 174 136 3500 800040-040-200 WS_25 7,0 62,9 209 170 3700 800050-050-160 WS_25 13,0 70,0 174 128 4400 800050-050-200 WS_25 9,4 69,4 209 165 3700 800065-065-160 WS_25 16,9 86,9 174 128 4400 800065-065-200 WS_25 13,8 83,1 219 170 3500 800080-080-160 WS_25 21,0 92,0 174 132 3900 800100-100-160 WS_25 31,6 124,0 174 138 3500 800
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
8 Etabloc SYT/ Etaline SYT
Selection charts
Etabloc SYT, n = 2900 rpm
H[m]
Q [m³/h]2 3 4 5 10 20 30 40 50 100 200 290
10 20 30 40 50 100 200 300 400 500 1000US.gpm
10 20 30 40 50 100 200 300 400 500 1000IM.gpm
10
20
30
40
50
9
70
30
40
50
100
200
ft
1 2 3 4 5 10 20 30 40 50l/s
061-08-001
002-56-08
061-56-08
002-05-56
061-05-56
002-04-56
061-04-56
002-23-05
1.002-23-05
061-23-05
1.061-23-05
1.521-23-05
002-52-04
061-52-04
Etabloc SYT, n = 1450 rpm
H[m]
Q [m³/h]1 2 3 4 5 10 20 30 40 50 1000.7 160
4 5 10 20 30 40 50 100 200 300 400 500US.gpm
3 4 5 10 20 30 40 50 100 200 300 400 500IM.gpm
2
3
4
5
10
20
10
20
30
40
50
ft
0.2 0.3 0.4 0.5 1 2 3 4 5 10 20 30 40l/s
061-08-001
002-56-08
061-56-08
002-05-56
061-05-56
002-04-56
061-04-56
002-23-05 1.002-23-05
061-23-05 1.061-23-05
1.521-23-05
002-52-04
061-52-04
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 9
Etabloc SYT, n = 3500 rpm
KE1172.4062 / 1
H[m]
Q [m³/h]3 4 5 10 20 30 40 50 100 200 300 360
20 30 40 50 100 200 300 400 500 1000[US.gpm]
20 30 40 50 100 200 300 400 500 1000[IM.gpm]
10
20
30
40
50
100
110
40
50
100
200
300
[ft]
1 2 3 4 5 10 20 30 40 50 100[l/s]
061-08-001
002-56-08
061-56-08
002-05-56
061-05-56
002-04-56
061-04-56
002-23-05
061-23-05
1.002-23-05
1.061-23-05
1.521-23-05
002-52-04
061-52-04
Etabloc SYT, n = 1750 rpm
KE1172.4064 / 1
H[m]
Q [m³/h]1 2 3 4 5 10 20 30 40 50 100 180
5 10 20 30 40 50 100 200 300 400 500[US.gpm]
4 5 10 20 30 40 50 100 200 300 400 500[IM.gpm]
3
4
5
10
20
30
10
20
30
40
50
[ft]
0.3 0.4 0.5 1 2 3 4 5 10 20 30 40 50[l/s]
061-08-001
002-56-08
061-56-08
002-05-56
061-05-56
002-04-56
061-04-56
002-23-05 1.002-23-05
061-23-05 1.061-23-05
1.521-23-05
002-52-04
061-52-04
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
10 Etabloc SYT/ Etaline SYT
Etaline SYT, n = 2900 rpm
K1172.4052 / 1
H[m]
Q [m³/h]10 20 30 40 50 100 200 300 350
50 100 200 300 400 500 1000[US.gpm]
40 50 100 200 300 400 500 1000[IM.gpm]
4
5
10
20
30
40
50
75
H[m]
20
30
40
50
100
200
[ft]
3 4 5 10 20 30 40 50[l/s]
061-001-001
061-08-08
002-56-56
061-56-56
002-05-05
061-05-05
002-04-04
061-04-04
002-23-23
061-23-23
Etaline SYT, n = 1450 rpm
K1172.4054 / 1
H[m]
Q [m³/h]5 10 20 30 40 50 100 150
30 40 50 100 200 300 400 500[US.gpm]
20 30 40 50 100 200 300 400 500[IM.gpm]
1
2
3
4
5
10
20
4
5
10
20
30
40
50
[ft]
2 3 4 5 10 20 30 40[l/s]
061-001-001
061-08-08
002-56-56
061-56-56
002-05-05
061-05-05 061-04-04
002-04-04 002-23-23
061-23-23
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 11
Etaline SYT, n = 3500 rpm
K1172.4062 / 1
H[m]
Q [m³/h]10 20 30 40 50 100 200 250
50 100 200 300 400 500 1000[US.gpm]
40 50 100 200 300 400 500[IM.gpm]
10
20
30
40
50
100
200
6 20
30
40
50
100
200
300
400
500
[ft]
3 4 5 10 20 30 40 50[l/s]
061-08-08
002-56-56
061-56-56
002-05-05
061-05-05
002-04-04
061-04-04
002-23-23
061-23-23
Etaline SYT, n = 1750 rpm
K1172.4064 / 1
H[m]
Q [m³/h]10 20 30 40 50 1008 180
40 50 100 200 300 400 500[US.gpm]
30 40 50 100 200 300 400 500[IM.gpm]
1
2
3
4
5
10
20
30
4
5
10
20
30
40
50
[ft]
3 4 5 10 20 30 40 50[l/s]
061-001-001 061-08-08
002-56-56
061-56-56
002-05-05
061-05-05
002-04-04
061-04-04
002-23-23
061-23-23
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
12 Etabloc SYT/ Etaline SYT
Dimensions
Etabloc SYT, 2-pole
wc
a
d2d3
l1 x
DN2
DN1
m2
m1
n1
n2
b1
d1
a1 p
h2
h1
s 1UG 1444157_CD2_D01/01UG 1444168_CD2_D01/01
wc
a
d2
d3
l 1x
DN2
DN1
Dimensions
Etab
loc SY
T/ Etaline SY
T13
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Dimensions, Etabloc SYT, 2-pole [mm]
Size
Etabloc SYT
Mo
tor
size
Motor rating [kW]
Ratedcurrent
[~A]
DN1 DN2 a a1 b1 c d2 d3 h1 h2 l1 m1 m2 n1 n2 p s1 w x
At50 Hz
At60 Hz
At400 V, 50 Hz
040-025-160 80M 0,75 - 1,75 40 25 80 118 50 301 200 162 132 160 657 100 70 240 190 118 15 322 100040-025-160 80M 1,10 1,27 2,41 40 25 80 118 50 301 200 162 132 160 671 100 70 240 190 118 15 322 100040-025-160 90S 1,50 1,75 3,15 40 25 80 118 50 301 200 190 132 160 684 100 70 240 190 118 15 322 100040-025-160 90L 2,20 2,55 4,46 40 25 80 118 50 301 200 190 132 160 710 100 70 240 190 118 15 322 100040-025-160 100L - 3,45 6,09 40 25 80 118 50 301 250 213 132 160 744 100 70 240 190 118 15 317 100040-025-160 112M - 4,55 7,82 40 25 80 118 50 301 250 234 132 160 768 100 70 240 190 118 15 317 100 040-025-200 90S 1,50 - 3,15 40 25 80 142 50 301 200 190 160 180 684 100 70 240 190 142 15 322 100040-025-200 90L 2,20 - 4,46 40 25 80 142 50 301 200 190 160 180 710 100 70 240 190 142 15 322 100040-025-200 100L 3,00 3,45 6,09 40 25 80 142 50 301 250 213 160 180 744 100 70 240 190 142 15 317 100040-025-200 112M 4,00 4,55 7,82 40 25 80 142 50 301 250 234 160 180 768 100 70 240 190 142 15 317 100040-025-200 132S 5,50 6,30 10,49 40 25 80 142 50 324 300 266 160 180 833 100 70 240 190 142 15 340 100040-025-200 132S - 8,60 14,12 40 25 80 142 50 324 300 266 160 180 833 100 70 240 190 142 15 340 100 050-032-125.1 80M 0,75 - 1,75 50 32 80 116 50 301 200 162 1125) 140 657 100 70 190 140 116 15 322 100050-032-125.1 80M 1,10 - 2,41 50 32 80 116 50 301 200 162 1125) 140 671 100 70 190 140 116 15 322 100050-032-125.1 90S 1,50 - 3,15 50 32 80 116 50 301 200 190 1125) 140 684 100 70 190 140 116 15 322 100050-032-125.1 90L 2,20 - 4,46 50 32 80 116 50 301 200 190 1125) 140 710 100 70 190 140 116 15 322 100050-032-125.1 100L - 3,45 6,09 50 32 80 116 50 301 250 213 1125) 140 744 100 70 190 140 116 15 317 100050-032-125.1 112M - 4,55 7,82 50 32 80 116 50 301 250 234 1125) 140 768 100 70 190 140 116 15 317 100050-032-125.1 132S - 6,30 10,49 50 32 80 116 50 324 300 266 1126) 140 833 100 70 190 140 116 15 340 100
050-032-160.1 90S 1,50 - 3,15 50 32 80 116 50 301 200 190 132 160 684 100 70 240 190 121 15 322 100050-032-160.1 90L 2,20 2,55 4,46 50 32 80 116 50 301 200 190 132 160 710 100 70 240 190 121 15 322 100050-032-160.1 100L 3,00 3,45 6,09 50 32 80 116 50 301 250 213 132 160 744 100 70 240 190 121 15 317 100050-032-160.1 112M 4,00 4,55 7,82 50 32 80 116 50 301 250 234 132 160 768 100 70 240 190 121 15 317 100050-032-160.1 132S - 6,30 10,49 50 32 80 116 50 324 300 266 1325) 160 833 100 70 240 190 121 15 340 100050-032-160.1 132S - 8,60 14,12 50 32 80 116 50 324 300 266 1325) 160 833 100 70 240 190 121 15 340 100050-032-160.1 160M - 12,6 20,41 50 32 80 116 50 356 300 325 1327) 160 1000 100 70 240 190 121 15 374 100
050-032-200.1 100L 3,00 - 6,09 50 32 80 142 50 301 250 213 160 180 744 100 70 240 190 142 18 317 100050-032-200.1 112M 4,00 - 7,82 50 32 80 142 50 301 250 234 160 180 768 100 70 240 190 142 18 317 100050-032-200.1 132S 5,50 6,30 10,49 50 32 80 142 50 324 300 266 160 180 833 100 70 240 190 142 18 340 100050-032-200.1 132S 7,50 8,60 14,12 50 32 80 142 50 324 300 266 160 180 833 100 70 240 190 142 18 340 100
5) Pump feet shimmed 20 mm6) Pump feet shimmed 40 mm7) Pump feet shimmed 50 mm
14Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Size
Etabloc SYT
Mo
tor
size
Motor rating [kW]
Ratedcurrent
[~A]
DN1 DN2 a a1 b1 c d2 d3 h1 h2 l1 m1 m2 n1 n2 p s1 w x
At50 Hz
At60 Hz
At400 V, 50 Hz
050-032-200.1 160M - 12,6 20,41 50 32 80 142 50 356 350 325 1605) 180 1000 100 70 240 190 142 18 374 100050-032-200.1 160M - 17,3 27,25 50 32 80 142 50 356 350 325 1605) 180 1000 100 70 240 190 142 18 374 100
050-032-160 90L 2,20 - 4,46 50 32 80 118 50 301 200 190 132 160 710 100 70 240 190 128 15 322 100050-032-160 100L 3,00 3,45 6,09 50 32 80 118 50 301 250 213 132 160 744 100 70 240 190 128 15 317 100050-032-160 112M 4,00 4,55 7,82 50 32 80 118 50 301 250 234 132 160 768 100 70 240 190 128 15 317 100050-032-160 132S - 6,30 10,49 50 32 80 118 50 324 300 266 1325) 160 833 100 70 240 190 128 15 340 100050-032-160 132S - 8,60 14,12 50 32 80 118 50 324 300 266 1325) 160 833 100 70 240 190 128 15 340 100
050-032-200 112M 4,00 - 7,82 50 32 80 142 50 301 250 234 160 180 768 100 70 240 190 143 18 317 100050-032-200 132S 5,50 - 10,49 50 32 80 142 50 324 300 266 160 180 833 100 70 240 190 143 18 340 100050-032-200 132S 7,50 8,60 14,12 50 32 80 142 50 324 300 266 160 180 833 100 70 240 190 143 18 340 100050-032-200 160M 11,0 12,6 20,41 50 32 80 142 50 356 350 325 1605) 180 1000 100 70 240 190 143 18 374 100050-032-200 160M - 17,3 27,25 50 32 80 142 50 356 350 325 1605) 180 1000 100 70 240 190 143 18 374 100
065-040-160 100L 3,00 - 6,09 65 40 80 119 50 301 250 213 132 160 744 100 70 240 190 134 15 317 100065-040-160 112M 4,00 - 7,82 65 40 80 119 50 301 250 234 132 160 768 100 70 240 190 134 15 317 100065-040-160 132S 5,50 6,30 10,49 65 40 80 119 50 324 300 266 1325) 160 833 100 70 240 190 134 15 340 100065-040-160 132S 7,50 8,60 14,12 65 40 80 119 50 324 300 266 1325) 160 833 100 70 240 190 134 15 340 100065-040-160 160M - 12,6 20,41 65 40 80 119 50 356 350 325 1328) 160 1000 100 70 240 190 134 15 374 100065-040-160 160M - 17,3 27,25 65 40 80 119 50 356 350 325 1328) 160 1000 100 70 240 190 134 15 374 100
065-040-200 132S 5,50 - 10,49 65 40 100 142 50 324 300 266 160 180 853 100 70 265 212 155 18 340 100065-040-200 132S 7,50 - 14,12 65 40 100 142 50 324 300 266 160 180 853 100 70 265 212 155 18 340 100065-040-200 160M 11,0 12,6 20,41 65 40 100 142 50 356 350 325 1605) 180 1020 100 70 265 212 155 18 374 100065-040-200 160M 15,0 17,3 27,25 65 40 100 142 50 356 350 325 1605) 180 1020 100 70 265 212 155 18 374 100065-040-200 160L 18,5 21,3 33,38 65 40 100 142 50 356 350 325 1605) 180 1026 100 70 265 212 155 18 374 100065-040-200 180M 22,0 24,5 39,52 65 40 100 142 50 356 350 370 1605) 180 1084 100 70 265 212 155 18 374 100
065-050-160 132S 5,50 - 10,49 65 50 100 128 50 324 300 266 160 180 853 100 70 265 212 149 18 340 100065-050-160 132S 7,50 - 14,12 65 50 100 128 50 324 300 266 160 180 853 100 70 265 212 149 18 340 100065-050-160 160M 11,0 12,6 20,41 65 50 100 128 50 356 350 325 1605) 180 1020 100 70 265 212 149 18 374 100065-050-160 160M - 17,3 27,25 65 50 100 128 50 356 350 325 1605) 180 1020 100 70 265 212 149 18 374 100065-050-160 160L - 21,3 33,38 65 50 100 128 50 356 350 325 1605) 180 1026 100 70 265 212 149 18 374 100065-050-160 180M - 24,5 39,52 65 50 100 128 50 356 350 370 1605) 180 1084 100 70 265 212 149 18 374 100
8) Pump feet shimmed 30 mm
Etab
loc SY
T/ Etaline SY
T15
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Size
Etabloc SYT
Mo
tor
size
Motor rating [kW]
Ratedcurrent
[~A]
DN1 DN2 a a1 b1 c d2 d3 h1 h2 l1 m1 m2 n1 n2 p s1 w x
At50 Hz
At60 Hz
At400 V, 50 Hz
065-050-200 160M 11,0 - 20,41 65 50 100 144 50 356 350 325 1605) 200 1020 100 70 265 212 163 18 374 100065-050-200 160M 15,0 - 27,25 65 50 100 144 50 356 350 325 1605) 200 1020 100 70 265 212 163 18 374 100065-050-200 160L 18,5 - 33,38 65 50 100 144 50 356 350 325 1605) 200 1026 100 70 265 212 163 18 374 100065-050-200 180M 22,0 24,5 39,52 65 50 100 144 50 356 350 370 1605) 200 1084 100 70 265 212 163 18 374 100
080-065-160 132S 7,50 - 14,12 80 65 100 132 65 324 300 266 160 200 853 125 95 280 212 160 18 340 100080-065-160 160M 11,0 - 20,41 80 65 100 132 65 356 350 325 1605) 200 1020 125 95 280 212 160 18 374 100080-065-160 160M 15,0 17,3 27,25 80 65 100 132 65 356 350 325 1605) 200 1020 125 95 280 212 160 18 374 100080-065-160 160L - 21,3 33,38 80 65 100 132 65 356 350 325 1605) 200 1026 125 95 280 212 160 18 374 100080-065-160 180M - 24,5 39,52 80 65 100 132 65 356 350 370 1605) 200 1084 125 95 280 212 160 18 374 100
080-065-200 160M 15,0 - 27,25 80 65 100 155 65 356 350 325 180 225 1020 125 95 320 250 178 18 374 140080-065-200 160L 18,5 - 33,38 80 65 100 155 65 356 350 325 180 225 1026 125 95 320 250 178 18 374 140080-065-200 180M 22,0 24,5 39,52 80 65 100 155 65 356 350 370 180 225 1084 125 95 320 250 178 18 374 140 100-080-160 160M 15,0 - 27,25 100 80 125 138 65 356 350 325 180 225 1045 125 95 320 250 174 18 374 140100-080-160 160L 18,5 - 33,38 100 80 125 138 65 356 350 325 180 225 1051 125 95 320 250 174 18 374 140100-080-160 180M 22,0 24,5 39,52 100 80 125 138 65 356 350 370 180 225 1109 125 95 320 250 174 18 374 140
16Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Etabloc SYT, 4-pole
wc
a
d2d3
l1 x
DN2
DN1
m2
m1
n1
n2
b1
d1
a1 p
h2
h1
s 1UG 1444157_CD2_D01/01UG 1444168_CD2_D01/01
wc
a
d2
d3
l 1x
DN2
DN1
Dimensions
Etab
loc SY
T/ Etaline SY
T17
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Dimensions, Etabloc SYT, 4-pole [mm]
Size
Etabloc SYT
Mo
tor
size
Motor rating [kW]
Ratedcurrent
[~A]
DN1 DN2 a a1 b1 c d2 d3 h1 h2 l1 m1 m2 n1 n2 p s1 w x
At50 Hz
At60 Hz
At400 V, 50 Hz
040-025-160 80M - 0,63 1,46 40 25 80 118 50 301 200 162 132 160 657 100 70 240 190 118 15 322 100040-025-160 90S 1,10 1,27 2,51 40 25 80 118 50 301 200 190 132 160 684 100 70 240 190 118 15 322 100 040-025-200 80M 0,55 0,63 1,46 40 25 80 142 50 301 200 162 160 180 657 100 70 240 190 142 15 322 100040-025-200 80M - 0,86 1,67 40 25 80 142 50 301 200 162 160 180 657 100 70 240 190 142 15 322 100040-025-200 90S - 1,27 2,51 40 25 80 142 50 301 200 190 160 180 684 100 70 240 190 142 15 322 100 050-032-125.1 80M 0,55 0,63 1,46 50 32 80 116 50 301 200 162 1129) 140 657 100 70 190 140 116 15 322 100050-032-125.1 90S 1,10 1,27 2,51 50 32 80 116 50 301 200 190 1129) 140 684 100 70 190 140 116 15 322 100
050-032-160.1 80M 0,55 0,63 1,46 50 32 80 116 50 301 200 162 132 160 657 100 70 240 190 121 15 322 100050-032-160.1 80M - 0,86 1,67 50 32 80 116 50 301 200 162 132 160 657 100 70 240 190 121 15 322 100 050-032-200.1 80M 0,55 0,63 1,46 50 32 80 142 50 301 200 162 160 180 657 100 70 240 190 142 18 322 100050-032-200.1 80M 0,75 0,86 1,67 50 32 80 142 50 301 200 162 160 180 657 100 70 240 190 142 18 322 100050-032-200.1 90S - 1,27 2,51 50 32 80 142 50 301 200 190 160 180 684 100 70 240 190 142 18 322 100050-032-200.1 90L - 1,75 3,32 50 32 80 142 50 301 200 190 160 180 710 100 70 240 190 142 18 322 100 050-032-160 80M 0,55 0,63 1,46 50 32 80 118 50 301 200 162 132 160 657 100 70 240 190 128 15 322 100050-032-160 80M 0,75 0,86 1,67 50 32 80 118 50 301 200 162 132 160 657 100 70 240 190 128 15 322 100050-032-160 90S - 1,27 2,51 50 32 80 118 50 301 200 190 132 160 684 100 70 240 190 128 15 322 100 050-032-200 80M 0,55 - 1,46 50 32 80 142 50 301 200 162 160 180 657 100 70 240 190 143 18 322 100050-032-200 80M 0,75 - 1,67 50 32 80 142 50 301 200 162 160 180 657 100 70 240 190 143 18 322 100050-032-200 90S 1,10 1,27 2,51 50 32 80 142 50 301 200 190 160 180 684 100 70 240 190 143 18 322 100050-032-200 90L - 1,75 3,32 50 32 80 142 50 301 200 190 160 180 710 100 70 240 190 143 18 322 100050-032-200 100L - 2,55 4,67 50 32 80 142 50 301 250 213 160 180 744 100 70 240 190 143 18 317 100 065-040-160 80M 0,55 - 1,46 65 40 80 119 50 301 200 162 132 160 657 100 70 240 190 134 15 322 100065-040-160 80M 0,75 0,86 1,67 65 40 80 119 50 301 200 162 132 160 657 100 70 240 190 134 15 322 100065-040-160 90S 1,10 1,27 2,51 65 40 80 119 50 301 200 190 132 160 684 100 70 240 190 134 15 322 100065-040-160 90L - 1,75 3,32 65 40 80 119 50 301 200 190 132 160 710 100 70 240 190 134 15 322 100065-040-160 100L - 2,55 4,67 65 40 80 119 50 301 250 213 132 160 744 100 70 240 190 134 15 317 100 065-040-200 80M 0,75 - 1,67 65 40 100 142 50 301 200 162 160 180 677 100 70 265 212 155 18 322 100065-040-200 90S 1,10 - 2,51 65 40 100 142 50 301 200 190 160 180 704 100 70 265 212 155 18 322 100
9) Pump feet shimmed 20 mm
18Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Size
Etabloc SYT
Mo
tor
size
Motor rating [kW]
Ratedcurrent
[~A]
DN1 DN2 a a1 b1 c d2 d3 h1 h2 l1 m1 m2 n1 n2 p s1 w x
At50 Hz
At60 Hz
At400 V, 50 Hz
065-040-200 90L 1,50 1,75 3,32 65 40 100 142 50 301 200 190 160 180 730 100 70 265 212 155 18 322 100065-040-200 100L - 2,55 4,67 65 40 100 142 50 301 250 213 160 180 764 100 70 265 212 155 18 317 100065-040-200 100L - 3,45 6,18 65 40 100 142 50 301 250 213 160 180 799 100 70 265 212 155 18 317 100 065-050-160 80M 0,75 - 1,67 65 50 100 128 50 301 200 162 160 180 677 100 70 265 212 149 18 322 100065-050-160 90S 1,10 1,27 2,51 65 50 100 128 50 301 200 190 160 180 704 100 70 265 212 149 18 322 100065-050-160 90L 1,50 1,75 3,32 65 50 100 128 50 301 200 190 160 180 730 100 70 265 212 149 18 322 100065-050-160 100L - 2,55 4,67 65 50 100 128 50 301 250 213 160 180 764 100 70 265 212 149 18 317 100065-050-160 100L - 3,45 6,18 65 50 100 128 50 301 250 213 160 180 799 100 70 265 212 149 18 317 100 065-050-200 90L 1,50 - 3,32 65 50 100 144 50 301 200 190 160 200 730 100 70 265 212 163 18 322 100065-050-200 100L 2,20 2,55 4,67 65 50 100 144 50 301 250 213 160 200 764 100 70 265 212 163 18 317 100065-050-200 100L 3,00 3,45 6,18 65 50 100 144 50 301 250 213 160 200 799 100 70 265 212 163 18 317 100065-050-200 112M - 4,55 8,23 65 50 100 144 50 301 250 234 160 200 788 100 70 265 212 163 18 317 100065-050-200 132S - 6,30 11,32 65 50 100 144 50 324 300 266 160 200 853 100 70 265 212 163 18 340 100 080-065-160 90S 1,10 - 2,51 80 65 100 132 65 301 200 190 160 200 704 125 95 280 212 160 18 322 100080-065-160 90L 1,50 1,75 3,32 80 65 100 132 65 301 200 190 160 200 730 125 95 280 212 160 18 322 100080-065-160 100L 2,20 2,55 4,67 80 65 100 132 65 301 250 213 160 200 764 125 95 280 212 160 18 317 100080-065-160 100L - 3,45 6,18 80 65 100 132 65 301 250 213 160 200 799 125 95 280 212 160 18 317 100080-065-160 112M - 4,55 8,23 80 65 100 132 65 301 250 234 160 200 788 125 95 280 212 160 18 317 100080-065-160 132S - 6,30 11,32 80 65 100 132 65 324 300 266 160 200 853 125 95 280 212 160 18 340 100 080-065-200 100L 2,20 - 4,67 80 65 100 155 65 301 250 213 180 225 764 125 95 320 250 178 18 317 140080-065-200 100L 3,00 3,45 6,18 80 65 100 155 65 301 250 213 180 225 799 125 95 320 250 178 18 317 140080-065-200 112M 4,00 4,55 8,23 80 65 100 155 65 301 250 234 180 225 788 125 95 320 250 178 18 317 140080-065-200 132S - 6,30 11,32 80 65 100 155 65 324 300 266 180 225 853 125 95 320 250 178 18 340 140080-065-200 132M - 8,60 14,70 80 65 100 155 65 324 300 298 180 225 881 125 95 320 250 178 18 340 140 100-080-160 90L 1,50 - 3,32 100 80 125 138 65 301 200 190 180 225 755 125 95 320 250 174 18 322 140100-080-160 100L 2,20 - 4,67 100 80 125 138 65 301 250 213 180 225 789 125 95 320 250 174 18 317 140100-080-160 100L 3,00 3,45 6,18 100 80 125 138 65 301 250 213 180 225 824 125 95 320 250 174 18 317 140100-080-160 112M - 4,55 8,23 100 80 125 138 65 301 250 234 180 225 813 125 95 320 250 174 18 317 140100-080-160 132S - 6,30 11,32 100 80 125 138 65 324 300 266 180 225 878 125 95 320 250 174 18 340 140
Etab
loc SY
T/ Etaline SY
T19
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Etaline SYT, 2-pole
l1
l2
UG1444214_CD2_D01/02
UG1444218_CD2_D01_001/04
a wDN
DN
l1
l2
d2 d3
x
b1 b2
h1
h2
aw
DNDN
l 1
l 2
d2
d3
x
4x Ø16
a
d1
25
t
60
t
UG1444218_CD2_D01_002/04
Ym1
o
50
(45) (45)
50
Ø11,5
m2
Y
UG1444218_CD2_D01_003/04Z
Z
a
d1t
40 4x Ø16
(Ø 424,3)
300
348
Dimensions of the pump setDimensions for fastening a vertically installed pump set to the foundation
Detailed view Y 3 feet up to size Etaline SYT 080-080-160Detailed view Z 1 foot from size Etaline SYT 100-100-160
20Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Dimensions, Etaline SYT, 2-pole [mm]
Size
Etaline SYT
Motorsize
Motor rating [kW]
Rated current [~A]
DN a b1 b2 d1 d2 d3 h1 h2 l1 l2 m1 m2 o t w x
At50 Hz
At60 Hz
At400 V, 50 Hz
032-032-160 80M 1,10 - 2,41 32 87 119 131 M10 200 162 180 160 678 591 175 100 190 12,5 322 100032-032-160 90S 1,50 1,75 3,15 32 87 119 131 M10 200 190 180 160 691 604 175 100 190 12,5 322 100032-032-160 90L 2,20 2,55 4,46 32 87 119 131 M10 200 190 180 160 717 630 175 100 190 12,5 322 100032-032-160 100L 3,00 3,45 6,09 32 87 119 131 M10 250 213 180 160 751 664 175 100 190 12,5 317 100032-032-160 112M 4,00 4,55 7,82 32 87 119 131 M10 250 234 180 160 775 688 175 100 190 12,5 317 100032-032-160 132S 5,50 6,30 10,49 32 87 119 131 M10 300 266 180 160 840 753 175 100 190 12,5 340 100032-032-160 132S - 8,60 14,12 32 87 119 131 M10 300 266 180 160 840 753 175 100 190 12,5 340 100 032-032-200 100L 3,00 - 6,09 32 100 134 146 M10 250 213 250 190 764 664 175 100 190 12,5 317 100032-032-200 112M 4,00 4,55 7,82 32 100 134 146 M10 250 234 250 190 788 688 175 100 190 12,5 317 100032-032-200 132S 5,50 6,30 10,49 32 100 134 146 M10 300 266 250 190 853 753 175 100 190 12,5 340 100032-032-200 132S 7,50 8,60 14,12 32 100 134 146 M10 300 266 250 190 853 753 175 100 190 12,5 340 100032-032-200 160M 11,00 12,60 20,41 32 100 134 146 M10 350 325 250 190 1020 920 175 100 190 12,5 374 100032-032-200 160M - 17,30 27,25 32 100 134 146 M10 350 325 250 190 1020 920 175 100 190 12,5 374 100 040-040-160 90L 2,20 - 4,46 40 114 118 132 M10 200 190 180 160 744 630 165 90 190 12,5 322 100040-040-160 100L 3,00 3,45 6,09 40 114 118 132 M10 250 213 180 160 778 664 165 90 190 12,5 317 100040-040-160 112M 4,00 4,55 7,82 40 114 118 132 M10 250 234 180 160 802 688 165 90 190 12,5 317 100040-040-160 132S 5,50 6,30 10,49 40 114 118 132 M10 300 266 180 160 867 753 165 90 190 12,5 340 100040-040-160 132S 7,50 8,60 14,12 40 114 118 132 M10 300 266 180 160 867 753 165 90 190 12,5 340 100040-040-160 160M - 12,60 20,41 40 114 118 132 M10 350 325 180 160 1034 920 165 90 190 12,5 374 100 040-040-200 100L 3,00 - 6,09 40 110 138 150 M10 250 213 215 210 774 664 175 100 190 12,5 317 100040-040-200 112M 4,00 - 7,82 40 110 138 150 M10 250 234 215 210 798 688 175 100 190 12,5 317 100040-040-200 132S 5,50 - 10,49 40 110 138 150 M10 300 266 215 210 863 753 175 100 190 12,5 340 100040-040-200 132S 7,50 8,60 14,12 40 110 138 150 M10 300 266 215 210 863 753 175 100 190 12,5 340 100040-040-200 160M 11,00 12,60 20,41 40 110 138 150 M10 350 325 215 210 1030 920 175 100 190 12,5 374 100040-040-200 160M 15,00 17,30 27,25 40 110 138 150 M10 350 325 215 210 1030 920 175 100 190 12,5 374 100040-040-200 160L - 21,30 33,38 40 110 138 150 M10 350 325 215 210 1036 926 175 100 190 12,5 374 100 050-050-160 90L 2,20 - 4,46 50 134 116 135 M10 200 190 250 190 764 630 175 100 190 12,5 322 100050-050-160 100L 3,00 3,45 6,09 50 134 116 135 M10 250 213 250 190 798 664 175 100 190 12,5 317 100050-050-160 112M 4,00 4,55 7,82 50 134 116 135 M10 250 234 250 190 822 688 175 100 190 12,5 317 100050-050-160 132S 5,50 6,30 10,49 50 134 116 135 M10 300 266 250 190 887 753 175 100 190 12,5 340 100050-050-160 132S 7,50 8,60 14,12 50 134 116 135 M10 300 266 250 190 887 753 175 100 190 12,5 340 100050-050-160 160M 11,00 12,60 20,41 50 134 116 135 M10 350 325 250 190 1054 920 175 100 190 12,5 374 100050-050-160 160M - 17,30 27,25 50 134 116 135 M10 350 325 250 190 1054 920 175 100 190 12,5 374 100 050-050-200 112M 4,00 - 7,82 50 128 139 158 M10 250 234 220 220 816 688 175 100 190 12,5 317 100050-050-200 132S 5,50 - 10,49 50 128 139 158 M10 300 266 220 220 881 753 175 100 190 12,5 340 100050-050-200 132S 7,50 8,60 14,12 50 128 139 158 M10 300 266 220 220 881 753 175 100 190 12,5 340 100
Etab
loc SY
T/ Etaline SY
T21
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Size
Etaline SYT
Motorsize
Motor rating [kW]
Rated current [~A]
DN a b1 b2 d1 d2 d3 h1 h2 l1 l2 m1 m2 o t w x
At50 Hz
At60 Hz
At400 V, 50 Hz
050-050-200 160M 11,00 12,60 20,41 50 128 139 158 M10 350 325 220 220 1048 920 175 100 190 12,5 374 100050-050-200 160M 15,00 17,30 27,25 50 128 139 158 M10 350 325 220 220 1048 920 175 100 190 12,5 374 100050-050-200 160L 18,50 21,30 33,38 50 128 139 158 M10 350 325 220 220 1054 926 175 100 190 12,5 374 100050-050-200 180M - 24,50 39,52 50 128 139 158 M10 350 370 220 220 1112 984 175 100 190 12,5 374 100 065-065-160 100L 3,00 - 6,09 65 150 114 135 M10 250 213 270 170 814 664 175 100 210 12,5 317 100065-065-160 112M 4,00 - 7,82 65 150 114 135 M10 250 234 270 170 838 688 175 100 210 12,5 317 100065-065-160 132S 5,50 6,30 10,49 65 150 114 135 M10 300 266 270 170 903 753 175 100 210 12,5 340 100065-065-160 132S 7,50 8,60 14,12 65 150 114 135 M10 300 266 270 170 903 753 175 100 210 12,5 340 100065-065-160 160M 11,00 12,60 20,41 65 150 114 135 M10 350 325 270 170 1070 920 175 100 210 12,5 374 100065-065-160 160M 15,00 17,30 27,25 65 150 114 135 M10 350 325 270 170 1070 920 175 100 210 12,5 374 100065-065-160 160L 18,50 21,30 33,38 65 150 114 135 M10 350 325 270 170 1076 926 175 100 210 12,5 374 100065-065-160 180M - 24,50 39,52 65 150 114 135 M10 350 370 270 170 1134 984 175 100 210 12,5 374 100 065-065-200 132S 7,50 - 14,12 65 131 145 168 M10 300 266 240 235 903 772 195 120 220 12,5 359 100065-065-200 160M 11,00 12,60 20,41 65 131 145 168 M10 350 325 240 235 1070 939 195 120 220 12,5 393 100065-065-200 160M 15,00 17,30 27,25 65 131 145 168 M10 350 325 240 235 1070 939 195 120 220 12,5 393 100065-065-200 160L 18,50 21,30 33,38 65 131 145 168 M10 350 325 240 235 1076 945 195 120 220 12,5 393 100065-065-200 180M 22,00 24,50 39,52 65 131 145 168 M10 350 370 240 235 1134 1003 195 120 220 12,5 393 100 080-080-160 132S 5,50 - 10,49 80 176 119 147 M10 300 266 260 180 929 753 175 100 230 12,5 340 100080-080-160 132S 7,50 8,60 14,12 80 176 119 147 M10 300 266 260 180 929 753 175 100 230 12,5 340 100080-080-160 160M 11,00 12,60 20,41 80 176 119 147 M10 350 325 260 180 1096 920 175 100 230 12,5 374 100080-080-160 160M 15,00 17,30 27,25 80 176 119 147 M10 350 325 260 180 1096 920 175 100 230 12,5 374 100080-080-160 160L 18,50 21,30 33,38 80 176 119 147 M10 350 325 260 180 1102 926 175 100 230 12,5 374 100080-080-160 180M - 24,50 39,52 80 176 119 147 M10 350 370 260 180 1160 984 175 100 230 12,5 374 100 100-100-160 160M 11,00 - 20,41 100 156 128 163 M20 350 325 245 205 1102 946 - - - 25,0 400 140100-100-160 160M 15,00 - 27,25 100 156 128 163 M20 350 325 245 205 1102 946 - - - 25,0 400 140100-100-160 160L 18,50 - 33,38 100 156 128 163 M20 350 325 245 205 1108 952 - - - 25,0 400 140100-100-160 180M 22,00 - 39,52 100 156 128 163 M20 350 370 245 205 1166 1010 - - - 25,0 400 140
22Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Etaline SYT, 4-pole
l1
l2
UG1444214_CD2_D01/02
UG1444218_CD2_D01_001/04
a wDN
DN
l1
l2
d2 d3
x
b1 b2
h1
h2
aw
DNDN
l 1
l 2
d2
d3
x
4x Ø16
a
d1
25
t
60
t
UG1444218_CD2_D01_002/04
Ym1
o
50
(45) (45)
50
Ø11,5
m2
Y
UG1444218_CD2_D01_003/04Z
Z
a
d1t
40 4x Ø16
(Ø 424,3)
300
348
Dimensions of the pump setDimensions for fastening a vertically installed pump set to the foundation
Detailed view Y 3 feet up to size Etaline SYT 080-080-160Detailed view Z 1 foot from size Etaline SYT 100-100-160
Etab
loc SY
T/ Etaline SY
T23
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Dimensions, Etaline SYT, 4-pole [mm]
Size
Etaline SYT
Motorsize
Motor rating [kW]
Rated current [~A]
DN a b1 b2 d1 d2 d3 h1 h2 l1 l2 m1 m2 o t w x
At50 Hz
At60 Hz
At400 V, 50 Hz
032-032-160 080M 0,55 0,63 1,46 32 87 119 131 M10 200 162 180 160 664 577 175 100 190 12,5 322 100032-032-160 080M 0,75 0,86 1,67 32 87 119 131 M10 200 162 180 160 664 577 175 100 190 12,5 322 100032-032-160 90S - 1,27 2,51 32 87 119 131 M10 200 190 180 160 691 604 175 100 190 12,5 322 100 032-032-200 080M 0,55 - 1,46 32 100 134 146 M10 200 162 250 190 677 577 175 100 190 12,5 322 100032-032-200 080M 0,75 0,86 1,67 32 100 134 146 M10 200 162 250 190 677 577 175 100 190 12,5 322 100032-032-200 090S 1,10 1,27 2,51 32 100 134 146 M10 200 190 250 190 704 604 175 100 190 12,5 322 100032-032-200 90L - 1,75 3,32 32 100 134 146 M10 200 190 250 190 730 630 175 100 190 12,5 322 100032-032-200 100L - 2,55 4,67 32 100 134 146 M10 250 213 250 190 764 664 175 100 190 12,5 317 100 040-040-160 80M 0,55 0,63 1,46 40 114 118 132 M10 200 162 180 160 691 577 165 90 190 12,5 322 100040-040-160 80M 0,75 0,86 1,67 40 114 118 132 M10 200 162 180 160 691 577 165 90 190 12,5 322 100040-040-160 90S 1,10 1,27 2,51 40 114 118 132 M10 200 190 180 160 718 604 165 90 190 12,5 322 100040-040-160 90L - 1,75 3,32 40 114 118 132 M10 200 190 180 160 744 630 165 90 190 12,5 322 100 040-040-200 80M 0,55 - 1,46 40 110 138 150 M10 200 162 215 210 687 577 175 100 190 12,5 322 100040-040-200 80M 0,75 0,86 1,67 40 110 138 150 M10 200 162 215 210 687 577 175 100 190 12,5 322 100040-040-200 90S 1,10 1,27 2,51 40 110 138 150 M10 200 190 215 210 714 604 175 100 190 12,5 322 100040-040-200 90L 1,50 1,75 3,32 40 110 138 150 M10 200 190 215 210 740 630 175 100 190 12,5 322 100040-040-200 100L 2,20 2,55 4,67 40 110 138 150 M10 250 213 215 210 774 664 175 100 190 12,5 317 100040-040-200 100L - 3,45 6,18 40 110 138 150 M10 250 213 215 210 809 699 175 100 190 12,5 317 100 050-050-160 80M 0,55 0,63 1,46 50 134 116 135 M10 200 162 250 190 711 577 175 100 190 12,5 322 100050-050-160 80M 0,75 0,86 1,67 50 134 116 135 M10 200 162 250 190 711 577 175 100 190 12,5 322 100050-050-160 90S 1,10 1,27 2,51 50 134 116 135 M10 200 190 250 190 738 604 175 100 190 12,5 322 100050-050-160 90L 1,50 1,75 3,32 50 134 116 135 M10 200 190 250 190 764 630 175 100 190 12,5 322 100050-050-160 100L - 2,55 4,67 50 134 116 135 M10 250 213 250 190 798 664 175 100 190 12,5 317 100 050-050-200 80M 0,75 - 1,67 50 128 139 158 M10 200 162 220 220 705 577 175 100 190 12,5 322 100050-050-200 90S 1,10 1,27 2,51 50 128 139 158 M10 200 190 220 220 732 604 175 100 190 12,5 322 100050-050-200 90L 1,50 1,75 3,32 50 128 139 158 M10 200 190 220 220 758 630 175 100 190 12,5 322 100050-050-200 100L 2,20 2,55 4,67 50 128 139 158 M10 250 213 220 220 792 664 175 100 190 12,5 317 100050-050-200 100L 3,00 3,45 6,18 50 128 139 158 M10 250 213 220 220 827 699 175 100 190 12,5 317 100050-050-200 112M - 4,55 8,23 50 128 139 158 M10 250 234 220 220 816 688 175 100 190 12,5 317 100 065-065-160 80M 0,55 0,63 1,46 65 150 114 135 M10 200 162 270 170 727 577 175 100 210 12,5 322 100065-065-160 80M 0,75 0,86 1,67 65 150 114 135 M10 200 162 270 170 727 577 175 100 210 12,5 322 100065-065-160 90S 1,10 1,27 2,51 65 150 114 135 M10 200 190 270 170 754 604 175 100 210 12,5 322 100065-065-160 90L 1,50 1,75 3,32 65 150 114 135 M10 200 190 270 170 780 630 175 100 210 12,5 322 100065-065-160 100L 2,20 2,55 4,67 65 150 114 135 M10 250 213 270 170 814 664 175 100 210 12,5 317 100065-065-160 100L - 3,45 6,18 65 150 114 135 M10 250 213 270 170 849 699 175 100 210 12,5 317 100
24Etab
loc SY
T/ Etaline SY
T
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Size
Etaline SYT
Motorsize
Motor rating [kW]
Rated current [~A]
DN a b1 b2 d1 d2 d3 h1 h2 l1 l2 m1 m2 o t w x
At50 Hz
At60 Hz
At400 V, 50 Hz
065-065-200 90S 1,10 - 2,51 65 131 145 168 M10 200 190 240 235 754 623 195 120 220 12,5 341 100065-065-200 90L 1,50 1,75 3,32 65 131 145 168 M10 200 190 240 235 780 649 195 120 220 12,5 341 100065-065-200 100L 2,20 2,55 4,67 65 131 145 168 M10 250 213 240 235 814 683 195 120 220 12,5 336 100065-065-200 100L 3,00 3,45 6,18 65 131 145 168 M10 250 213 240 235 849 718 195 120 220 12,5 336 100065-065-200 112M 4,00 4,55 8,23 65 131 145 168 M10 250 234 240 235 838 707 195 120 220 12,5 336 100065-065-200 132S 5,50 6,30 11,32 65 131 145 168 M10 300 266 240 235 903 772 195 120 220 12,5 359 100065-065-200 132M - 8,60 14,70 65 131 145 168 M10 300 298 240 235 931 800 195 120 220 12,5 359 100 080-080-160 80M 0,75 - 1,67 80 176 119 147 M10 200 162 260 180 753 577 175 100 230 12,5 322 100080-080-160 90S 1,10 1,27 2,51 80 176 119 147 M10 200 190 260 180 780 604 175 100 230 12,5 322 100080-080-160 90L 1,50 1,75 3,32 80 176 119 147 M10 200 190 260 180 806 630 175 100 230 12,5 322 100080-080-160 100L 2,20 2,55 4,67 80 176 119 147 M10 250 213 260 180 840 664 175 100 230 12,5 317 100080-080-160 100L 3,00 3,45 6,18 80 176 119 147 M10 250 213 260 180 875 699 175 100 230 12,5 317 100080-080-160 112M - 4,55 8,23 80 176 119 147 M10 250 234 260 180 864 688 175 100 230 12,5 317 100 100-100-160 90L 1,50 - 3,32 100 156 128 163 M20 200 190 245 205 812 656 - - - 25 348 140100-100-160 100L 2,20 2,55 4,67 100 156 128 163 M20 250 213 245 205 846 690 - - - 25 343 140100-100-160 100L 3,00 3,45 6,18 100 156 128 163 M20 250 213 245 205 881 725 - - - 25 343 140100-100-160 112M 4,00 4,55 8,23 100 156 128 163 M20 250 234 245 205 870 714 - - - 25 343 140100-100-160 132S - 6,30 11,32 100 156 128 163 M20 300 266 245 205 935 779 - - - 25 366 140
Etab
loc SY
T/ Etaline SY
T25
Cen
trifug
al Pum
ps w
ith Sh
aft SealTh
ermal O
il/Ho
t Water Pu
mp
s
Connection types
Connections of an Etabloc SYT pump
1M6D
1M
1M
6D
6D
6D.16D.1
6B6B8B
8B
1M6B
DN1
DN1
DN2
DN2
UG1444526_D01_001/01
UG
1444
526_
D02
_001
/01
Connection types by installation type
Connection types
Connection Description Configuration Location1M Pressure gauge connection Drilled and closed Suction and discharge flanges6B Fluid drain Drilled and closed Volute casing6D, 6D.1 Fluid priming and venting Drilled and closed Volute casing and bearing
housing8B Leakage drain Drilled Seal cover
Connection dimensions of an Etabloc SYT pump
SizeEtabloc SYT
Connections at thevolute casing
Connections at the bearing housing and seal cover
1M, 6B, 6D 6D.1 8B040-025-160 G 1/4 G 1/8 R 1/4040-025-200 G 1/4 G 1/8 R 1/4050-032-125.1 G 1/4 G 1/8 R 1/4050-032-160.1 G 1/4 G 1/8 R 1/4050-032-200.1 G 1/4 G 1/8 R 1/4050-032-160 G 1/4 G 1/8 R 1/4050-032-200 G 1/4 G 1/8 R 1/4065-040-160 G 1/4 G 1/8 R 1/4065-040-200 G 1/4 G 1/8 R 1/4065-050-160 G 1/4 G 1/8 R 1/4065-050-200 G 1/4 G 1/8 R 1/4080-065-160 G 3/8 G 1/8 R 1/4080-065-200 G 3/8 G 1/8 R 1/4100-080-160 G 3/8 G 1/8 R 1/4
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
26 Etabloc SYT/ Etaline SYT
Connections of an Etaline SYT pump
1M6D
1M6B
1M6D.3
6D.2
6D.1 6D.1
6B
6B
8B
8B
1M6D
DN
DN
DN
DN
UG1444659_D01_001/01
UG
1444
659_
D01
_003
/01
Connection types by installation type
Connection types
Connection Description Configuration Location1M Pressure gauge connection Drilled and closed Suction and discharge flanges6B Fluid drain Drilled and closed Volute casing6D, 6D.1, 6D.2,6D.3
Fluid priming and venting Drilled and closed Volute casing and bearinghousing
8B Leakage drain Drilled Seal cover
Connection dimensions of an Etaline SYT pump
SizeEtaline SYT
Connections at the volute casing Connections at the bearing housing and seal cover
1M, 6B, 6D, 6D.2, 6D.3 6D.1 8B032-032-160 G 1/4 G 1/8 R 1/4032-032-200 G 1/4 G 1/8 R 1/4040-040-160 G 1/4 G 1/8 R 1/4040-040-200 G 1/4 G 1/8 R 1/4050-050-160 G 1/4 G 1/8 R 1/4050-050-200 G 1/4 G 1/8 R 1/4065-065-160 G 1/4 G 1/8 R 1/4065-065-200 G 1/4 G 1/8 R 1/4080-080-160 G 3/8 G 1/8 R 1/4100-100-160 G 3/8 G 1/8 R 1/4
Flange design
Flange design by materials
Material variant Standard Nominal diameter Pressure classS EN 1092-2 DN 25 - DN 100 PN 16
Drilled to ASME B16.110) DN 25 - DN 100 Class 125
10) DN 80 machined like DN 100
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 27
Flange dimensions
Illustration of dimensions
Flange dimensions [mm]
DN / NPS Standard
EN 1092-2 ASME B 16.1
PN 16 Class 125
∅ K ∅ D Number and ∅ ofholes (∅ L)
∅ K ∅ D Number of holesL
25/ NPS 1 85 115 4 × ∅14 79,2 115 4×∅15,732/ NPS 1 1/4 100 140 4 × ∅19 88,9 140 4×∅15,740/ NPS 1 1/2 110 150 4 × ∅19 98,6 150 4×∅15,750/ NPS 2 125 165 4 × ∅19 120,7 165 4×∅19,165/ NPS 2 1/2 145 185 4 × ∅19 139,7 185 4×∅19,18011)/ NPS 3 160 200 / 22912) 8 × ∅19 152,4 200 / 22912) 4×∅19,1100/ NPS 4 180 230 8 × ∅19 190,5 230 8×∅19,1
Equivalents of DN 80 for a flange drilled to ASME (Etabloc SYT only)
Size Bearing housing Material variant
SG, SC
DN 1ASME 125
DN 2ASME 125
080-065-160 25 NPS 4 NPS 2 1/2080-065-200 25 NPS 4 NPS 2 1/2
Scope of supply
Depending on the model, the following items are included inthe scope of supply:
▪ Pump
▪ Drive
▪ Pump foot for vertical installation of the drive
11) On Etabloc SYT sizes 080-065-160 and 080-065-200 flanges DN 80 (NPS 3) are drilled to NPS 4. Also see the table onEquivalents.
12) Suction-side flange DN 80; applies to Etabloc SYT sizes 080-065-160 and 080-065-200 only. Also see the table onEquivalents.
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
28 Etabloc SYT/ Etaline SYT
General assembly drawings
Etabloc SYT exploded view
800
UG1445311_CDK_D02_001/01
680
(920.98)554.98
914.98
940.01
914.24
515341
680
902.11920.11
341901.72920.12
515914.24
680554.98914.98(920.98)
515 515914.24
210
210
550.95920.95930.95940.01
903.03
411.031M903.04
411.04
903.01
411.01 6B
1M6D 903.02
411.026D
102
102411.01/.02/.03/.04502.01902.01903.01/.02/.03/.04920.01
920.95930.95
550.95
902.01 230
502.01
502.02411.10
161161502.02902.15920.15
720.94
411.15
903.946D.1
411.94
350350310
903.926D.1
411.92 471 471902.02
920.01
902.15
920.15
920.02
902.02433
411.378B
720.25
902.85920.85
902.11 920.11
550.02932.04
310720.92
931 831
554.98 680 914.98 (920.98)
Etabloc SYT exploded view
[ Supplied in packaging units only( ) Not available as individual spare part
List of components
Part No. Description Part No. Description102 Volute casing 831 Fan impeller161 Casing cover 901.72 Hexagon head bolt210 Shaft 902.01/.02/.11/.15/.85 Stud230 Impeller 903.01/.02/.03/.04/.92/.94 Screw plug310 Plain bearing 914.24 Socket head cap screw341 Drive lantern 914.98 Pan head screw350 Bearing housing 920.01/.02/.11/.12/.15/.85/.95 Hexagon nut411.01/.02/.03/.04/.10/.15/.37/.92/.94 Joint ring 920.98 Blind rivet nut433 Mechanical seal 930.95 Spring washer471 Seal cover 931 Lock washer502.01/.02 Casing wear ring 932.04 Circlip515 Taper lock ring 940.01 Key550.02/.95 Disc Connections554.98 Lock washer 1M Connection for pressure gauge680 Guard 6B Fluid drain720.25/.92/.94 Fitting 6D, 6D.1 Fluid priming and venting800 Motor 8B Leakage drain
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 29
Etaline SYT exploded view
680
(920.98)554.98
914.98
940.01
914.24
515
680554.98914.98(920.98)
515 515914.24
210
210
550.95920.95930.95940.01
903.02411.02
1M6B
411.01
903.01
411.01
6B
1M6D
102
102411.01/.02/.39502.01902.01903.01/.02/.39920.01
920.95930.95
550.95
502.02411.10
161161502.02902.15920.15
720.94
411.15
903.946D.1
411.94
350 350310
903.926D.1
411.92 471471902.02
550.02932.04
310720.92
931 831
902.01
230502.01 920.01
902.15
920.15
920.02902.02
433
411.378B
720.25
902.85
920.85
902.11 920.11
800
UG1445618_CDK_D02_001/01
341
680
902.11920.11
341
6B
903.01903.39411.39
515914.24
554.98 680 914.98 (920.98)
Etaline SYT exploded view
[ Supplied in packaging units only( ) Not available as individual spare part
List of components
Part No. Description Part No. Description102 Volute casing 831 Fan impeller161 Casing cover 902.01/.02/.11/.15/.85 Stud210 Shaft 903.01/.02/.39/.92/.94 Screw plug230 Impeller 914.24 Socket head cap screw310 Plain bearing 914.98 Pan head screw341 Drive lantern 920.01/.02/.11/.15/.85/.95 Hexagon nut350 Bearing housing 920.98 Blind rivet nut411.01/.02/.10/.15/.37/.39/.92/.94 Joint ring 930.95 Spring washer433 Mechanical seal 931 Lock washer471 Seal cover 932.04 Circlip502.01/.02 Casing wear ring 940.01 Key515 Taper lock ring 550.02/.95 Disc Connections554.98 Lock washer 1M Connection for pressure gauge680 Guard 6B Fluid drain720.25/.92/.94 Fitting 6D, 6D.1 Fluid priming and venting800 Motor 8B Leakage drain
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
30 Etabloc SYT/ Etaline SYT
Detailed designation (Etabloc)
Designation example
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
E T B - 0 4 0 - 0 2 5 - 1 6 0 - G G - A I 0 1 D 2 1 1 0 0 2 - - B P D 2 -See name plate and data sheet See data sheet -
Key to the designation
Position Code Description1-4 Pump type
ETB EtablocETBF Etabloc design for bottle rinsingETBY Etabloc SYT
5-16 Size 040 Nominal suction nozzle diameter [mm]
025 Nominal discharge nozzle diameter [mm]160 Nominal impeller diameter [mm]
17 Pump casing material G JL 1040/A48CL35
S JS 1030C 1.4408/A743CF8MB CC480K-GS/B30 C90700
18 Impeller material G JL 1040/A48CL35
C 1.4408/A743CF8MB CC480K-GS/B30 C90700
19 Design -13) Standard
X Special design BT3D, BT3F Design for bottle rinsing
20 Casing cover A Conical seal chamber
C Cylindrical seal chamberD Casing cover for SYT (dead-end arrangement)
21 Seal variants B Dead-end arrangement (for Etabloc SYT only)
I Internal circulation (conical cover only)E External circulationF External flushingD Back-to-back arrangementT Tandem arrangement with internal circulationA Conical seal chamber without circulation
22-23 Seal code 01 1 (ZN1181) Q1Q1VGG
06 RMG13G606 U3BEGG (WE25, 35)07 1A (ZN1181) Q1Q1EGG08 M32N69 (SYT) AQ1VGG09 MG13G60 U3U3VGG10 1 (ZN1181) Q1Q1X4GG11 1 (ZN1181) BQ1EGG-WA12 M37GN83 Q12Q1M1GG13 1 (ZN1181) BQ1VGG14 KMB13S2G9 Q1Q1KY7G15 M7G49 Q1Q1K9GG/G16 MG1S20 BVPGG17 M7N Q1BVGG18 MG12G6-E1 Q1Q1EGG/G19 HN400N Q1Q1M1GG20 M37GN85 Q12Q1M1GG123 M37GN92 Q12Q1M1GG121 M7G49 Q1Q1K9GG/G
13) Blank
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 31
Position Code Description24 M7G49 Q1Q1K9GG/G22 M32N69 AQ1EGG (WE55)25 M32N67 (SYT) AQ1VGG-- BT399 Shaft seal ring Gohl version
24 Scope of supply A Pump only (Fig. 0)
D Etanorm: pump, baseplate, coupling, coupling guard, motor
Etabloc: pump, motor25 Shaft unit
2 Shaft unit 253 Shaft unit 355 Shaft unit 55
26-29 Motor rating 8750
6300 1100
30 Number of poles 2 2 poles
31-32 Explosion protection ex Explosion-proof motor
-- Without explosion-proof motor33 Product generation
B Product generation Etabloc/ Etabloc SYT GP
34-37 PumpDrive PDB PumpDrive 1st generation, Basic
PDA PumpDrive 1st generation, AdvancedPD2 PumpDrive 2nd generationPD2E PumpDrive 2nd generation, Eco
Detailed designation (Etaline)
Designation example
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
E T L - 0 3 2 - 0 3 2 - 1 6 0 - G G - A A 1 1 D 2 0 0 3 0 4 e x B S I E I E 3 P D 2 E MSee name plate and data sheet See data sheet
Key to the designation
Position Code Description1-4 Pump type
ETLY Etaline SYTETL- Etaline
5-16 Size 032 Nominal suction nozzle diameter [mm]
032 Nominal discharge nozzle diameter [mm]160 Nominal impeller diameter [mm]
17 Pump casing material G JL 1040/A48CL35
S JS 103018 Impeller material
G JL 1040/A48CL35C 1.4408/A743CF8MB CC480K-GS/B30 C90700
19 Design - Standard
X Special design BT3D, BT320 Casing cover
A Conical seal chamber
21 Type of seal B Dead-end arrangement (for Etaline SYT only)
V Conical seal chamber with vent
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
32 Etabloc SYT/ Etaline SYT
Position Code DescriptionA Conical seal chamber
22-23 Seal code 06 U3BEGG (shaft units 25, 35)
07 Q1Q1EGG08 AQ1VGG09 U3U3VGG10 Q1Q1X4GG11 BQ1EGG22 AQ1EGG (shaft unit 55)
24 Scope of supply A Pump only (Fig. 0)
D Pump, baseplate, coupling, coupling guard, motor25 Shaft unit
2 Shaft unit 253 Shaft unit 355 Shaft unit 55
26-29 Motor rating (basis: 50 Hz) 0002 0,25 KW
0003 0,37 KW0005 0,55 KW0007 0,75 KW0011 1,1 KW0015 1,5 KW0022 2,2 KW0030 3,0 KW0040 4,0 KW0055 5,5 KW0075 7,5 KW0110 11,0 KW0150 15,0 KW0185 18,5 KW0220 22,0 KW0300 30,0 KW0370 37,0 KW0450 45,0 KW0550 55,0 KW
30 Number of poles 2 2 poles
4 4 poles31-32 Explosion protection
ex Explosion-proof motor
-- Without explosion-proof motor
33 Product generation B Product generation Etaline / Etaline SYT GP
34-36 Motor manufacturer KSB KSB
SIE SiemensLOH LoherHAL Halter
37-39 Efficiency class IE1 IE1
IE2 IE2IE3 IE3IE4 IE4
40-43 PumpDrive PDB PumpDrive 1st generation, Basic
PDA PumpDrive 1st generation, AdvancedPD2 PumpDrive 2nd generationPD2E PumpDrive 2nd generation, Eco
44 PumpMeter M With PumpMeter
Centrifugal Pumps with Shaft SealThermal Oil/Hot Water Pumps
Etabloc SYT/ Etaline SYT 33
1172
.5/0
3-EN
02.0
2.20
16
KSB Aktiengesellschaft67225 Frankenthal • Johann-Klein-Str. 9 • 67227 Frankenthal (Germany)Tel. +49 6233 86-0 • Fax +49 6233 86-3401www.ksb.com