Cite this article as: Tomás AC, Santos ÁL, Rodrigues L, Fragata J. Type 3 endoleak following chest trauma in a patient with a hybrid replacement of the thoracic aorta. Eur J Cardiothorac Surg 2015; doi:10.1093/ejcts/ezv146. Type 3 endoleak following chest trauma in a patient with a hybrid replacement of the thoracic aorta António Cruz Tomás*, Álvaro Laranjeira Santos, Luís Rodrigues and José Fragata Serviço de Cirurgia Cardiotorácica, Hospital de Santa Marta, CHLC, Lisbon, Portugal * Corresponding author. Serviço de Cirurgia Cardiotorácica, Hospital de Santa Marta, Rua de Santa Marta 50, Lisboa 1169-1024, Portugal. Tel: +351-91-8600313; e-mail: [email protected] (A.C. Tomás). Received 19 January 2015; received in revised form 4 March 2015; accepted 16 March 2015 Keywords: Endoleak type 3 Endovascular Thoracic Aorta Frozen elephant trunk Chest trauma A 64-year old male patient underwent a frozen elephant trunk and thoracic endovascular aortic repair (TEVAR) in 2010 for a type B aortic dissection. Thrombosis of the false lumen was documented on angio-CT. In 2014, following chest trauma, he had an enlargement in the false lumen and a type 3 endoleak (Figs. 1AC; Video 1), treated with another TEVAR (Fig. 2AC). Figure 1: (AC) Angio-CT revealing the endoleak in the middle of the rst thoracic endovascular aortic repair. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. IMAGES IN CARDIO- THORACIC SURGERY European Journal of Cardio-Thoracic Surgery (2015) 12 IMAGES IN CARDIO-THORACIC SURGERY doi:10.1093/ejcts/ezv146 European Journal of Cardio-Thoracic Surgery Advance Access published April 17, 2015

Transcript of Type 3 endoleak following chest trauma in a patient with a...

  • Cite this article as: Toms AC, Santos L, Rodrigues L, Fragata J. Type 3 endoleak following chest trauma in a patient with a hybrid replacement of the thoracicaorta. Eur J Cardiothorac Surg 2015; doi:10.1093/ejcts/ezv146.

    Type 3 endoleak following chest trauma in a patient with a hybridreplacement of the thoracic aorta

    Antnio Cruz Toms*, lvaro Laranjeira Santos, Lus Rodrigues and Jos Fragata

    Servio de Cirurgia Cardiotorcica, Hospital de Santa Marta, CHLC, Lisbon, Portugal

    * Corresponding author. Servio de Cirurgia Cardiotorcica, Hospital de Santa Marta, Rua de Santa Marta 50, Lisboa 1169-1024, Portugal. Tel: +351-91-8600313;e-mail: [email protected] (A.C. Toms).

    Received 19 January 2015; received in revised form 4 March 2015; accepted 16 March 2015

    Keywords: Endoleak type 3 Endovascular Thoracic Aorta Frozen elephant trunk Chest trauma

    A 64-year old male patient underwent a frozen elephant trunkand thoracic endovascular aortic repair (TEVAR) in 2010 for a typeB aortic dissection. Thrombosis of the false lumen was

    documented on angio-CT. In 2014, following chest trauma, he hadan enlargement in the false lumen and a type 3 endoleak (Figs.1AC; Video 1), treated with another TEVAR (Fig. 2AC).

    Figure 1: (AC) Angio-CT revealing the endoleak in the middle of the first thoracic endovascular aortic repair.

    The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

    IMAGES

    INCARDIO

    -TH

    ORACIC

    SURGER

    Y

    European Journal of Cardio-Thoracic Surgery (2015) 12 IMAGES IN CARDIO-THORACIC SURGERYdoi:10.1093/ejcts/ezv146

    European Journal of Cardio-Thoracic Surgery Advance Access published April 17, 2015

  • Figure 2: (AC) Final result after deployment of a new thoracic endovascular aortic repair in the lumen of the affected prosthesis.

    Video 1: 3D Reconstruction of the angio-CT showing the type 3 endoleak andthe affected prosthesis.

    A.C. Toms et al. / European Journal of Cardio-Thoracic Surgery2

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 175 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50286 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG2000 /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages true /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 175 /MonoImageDepth 4 /MonoImageDownsampleThreshold 1.50286 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects true /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False