Transmission and Distribution Module2

download Transmission and Distribution  Module2

of 3

Transcript of Transmission and Distribution Module2

Module-2Set-1Short Questions1. Classify overhead transmission lines.2. Define transmission efficiency.3. List out the methods of representation of medium transmission lines.4. What is Ferranti effect?5. Define regulation of power transmission line.6. What is the use of power circle diagram?7. What is meant by the receiving end power circle diagram?8. What is the cause of Ferranti effect?9. What is the use of power circle diagram?10. What are the causes of voltage drop and line loss in a transmission line?

Long Questions1. Determine the efficiency and regulation of a 3phase, 100 Km, 50 Hz transmission line delivering 20 MW at a power factor of 0.8 lagging and66kV to a balanced load. The conductors are of copper, each having resistance 0.1 / Km, 1.5 cm outside dia, spaced equilaterally 2 meters between centers. Use nominal T method.2. A three phase 5 km long transmission line, having resistance of 0.5 / km and inductance of 1.76 mH / km is delivering power at 0.8pflagging. The receiving end voltage is 32kV. If the supply end voltage is 33 kV, 50 Hz, find line current,regulation and efficiency of the transmission line.3. Derive the expressions for sending end voltage in nominal T method and end Condenser method.4. i) What is an equivalentcircuit of long line? Derive expression for parameters of this circuit in terms of line parameters.ii) A 50Hz transmission line 300 km long total series impedance of 40+j25 and total shunt admittance of 10-3 mho. The 220 KV with0.8 lagging power factor. Find the sending end voltage, current,power and power factor usingnominalmethod.5. i) Define regulation of a transmission line and derive the approximate expression for the regulation of a short transmission line.ii) What is corona loss? How do you determine this loss?

Set-2Short Questions1. What are the advantages of using series compensation?2. What are the factors which govern the performance of a transmission line?3. What is shunt compensation?4. Distinguish attenuation and phase constant.5. Define surge impedance6. Draw the phasorrepresentation of short transmission line.7. For controlling reactive power what adjustment should be done in transformer present in the system?8. What is the purpose of insulator?9. What is the main purpose of armoring?10. What is meant by efficiency of an insulator string?

Long Questions6. A 220kV, 3 transmission line has an impedance per phase of (40+j200) and an admittance of (0+j0.0015) mho. Determine the sending end voltage and sending end current when the receiving end current is 200 A at 0.95 pf lagging.Use nominal T method.

7. Determine the efficiency and regulation of a three phase 200 km, 50 Hz transmission line delivering 100 MW at a pf of 0.8 lagging and 33 kV toa balanced load. The conductors are of copper, each having resistance 0.1 / km, and 1.5 cm outside diameter, spaced equilaterally 2 mbetween Centers. Neglect leakage reactance and use nominal T and methods.

8. i) Explain the Ferranti effect with a phasor diagram and its causes.ii) Explain the classification of lines based on their length of transmission.iii) What are ABCD constants.

9. A 3 phase line having an impedance of (5+j20) per phase delivers aload of 30MW at a power factor of 0.8 lag and voltage of 33 kV.Determine the capacity of the phase modifier to be installed at the receiving end if the voltage at the sending end is to be maintained at33kV. Assume the shunt admittance is neglected.

10. Write short notes on i) Shunt compensationii) Series compensation

Set-3Short Questions1. What are the factors which affect corona?2. Define transmission efficiency.3. List out various types of insulators used for overhead transmission lines.4. Mention the advantages of the pin type insulator5. What are the main causes for failure of insulators?6. What are the different tests that are conducted on an insulator?7. Define string efficiency and what are the methods for improving string efficiency?8. Write short notes on puncture test.9. Define impulse ratio.10. State advantage of polymeric insulators over porcelain insulators.

Long Questions1. A 3 phase, 50Hz, 150 km line has a resistance, inductive reactance andcapacitive shunt admittance of 0.1, 0.5 and 3*10-6mho per km perphase. If the line delivers 50MW at 110kV and 0.8pf lagging. Determine the sending end voltage and current. Assume nominal circuit for the line.2. A 15 km long 3 phase overhead line delivers 5 MW at 11kV at 0.8lagging pf line loss is 12% of power delivers. Line inductance is 1.1mHper km per phase. Find the sending end voltage and regulation.3. i) Explain surge impedance loading with respect to an overhead transmission line . ii) Explain the end condenser method for medium transmission lines.

4. The A,B,C,D constants of a 3 phase transmission line are A=D=0.936+j0.016, B=33.5+j138, C=(-0.9280+j901.223)*10-6mho.The load at the receiving end is 40MW at 220kV with power factor of 0.86 lagging. Find the magnitude of the sending end voltage, current, power, line efficiency and voltage regulation. Assume the magnitude of the sending end voltage remains constant.5. Deduce an expression for the sending end and receiving end power of aline in terms of voltage and ABCD constants. Show that the real power transferred is dependent on the power angle and reactive power transferred is dependent on the voltage drop in the line.