Trane Submittal 3 Ton Convertible Air Handler TAM4A0A36S31SA · 2021. 5. 11. · No. Used Drive -...

3
J4AH4P24A1B00AA SUBMITTAL TAG: _________________________________ 2.0 Ton Multi-position Air Handler UPFLOW UNIT SHOWN; UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY. A 10 5 16 NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLY AIR FLANGES ARE PROVIDED FOR FIELD INSTALLATION ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS LOW VOLTAGE CONNECTION BREAKER SWITCH (FOR ELECTRIC HEATER ONLY) VAPOR LINE CONNECTION COPPER (SWEAT) LIQUID LINE CONNECTION COPPER (SWEAT) AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) H D W J4AH4P24A1B00AA Model H W D A 1180 (46-1/2) 500 (19-5/8) 550 (21-5/8) 456 (18) NOTE: All dimensions are in mm/inches. J4AH4P24A1B00AA

Transcript of Trane Submittal 3 Ton Convertible Air Handler TAM4A0A36S31SA · 2021. 5. 11. · No. Used Drive -...

Page 1: Trane Submittal 3 Ton Convertible Air Handler TAM4A0A36S31SA · 2021. 5. 11. · No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors — H.P. Motor Speed R ... 240V 208V 240V

J4AH4P24A1B00AA

SUBMITTALTAG: _________________________________

2.0 Ton Multi-position Air Handler

UPFLOW UNIT SHOWN;UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.

A10 5 16

NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE.

SUPPLY AIR

FLANGES ARE PROVIDED FOR FIELD INSTALLATION

ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE

HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS

LOW VOLTAGE CONNECTION

BREAKER SWITCH (FOR ELECTRIC HEATER ONLY)

VAPOR LINE CONNECTION COPPER (SWEAT)

LIQUID LINE CONNECTION COPPER (SWEAT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

H

D

W

J4AH4P24A1B00AA

Model H W D A

1180 (46-1/2) 500 (19-5/8) 550 (21-5/8) 456 (18)

NOTE: All dimensions are in mm/inches.

J4AH4P24A1B00AA

Page 2: Trane Submittal 3 Ton Convertible Air Handler TAM4A0A36S31SA · 2021. 5. 11. · No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors — H.P. Motor Speed R ... 240V 208V 240V

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONSMODEL J4AH4P24A1B00AARATED VOLTS/PH/HZ. 208-230/1/60RATINGS INDOOR COIL — Type Plate FinRows — F.P.I. 4 - 17Face Area (sq. ft.) 4.01Tube Size (in.) 9/32Refrigerant Control OrificeDrain Conn. Size (in.) 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 10-5/8 X 10-3/4No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors — H.P. Motor Speed R.P.M. Volts/Ph/Hz F.L. AmpsFILTERFilter Furnished?Type RecommendedNo.-Size-Thickness

1Direct - 3

See Fan Performance Table 1 - 1/5

755208-230/1/60

1.2

NoThrowaway

1 - 18X 20 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 3/4Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.)

46-1/2 x 19-5/8 x 21-5/8Uncrated 47-4/5 x 22-3/5 x 25-7/10

WEIGHTShipping (Lbs.) / Net (Lbs.) 141/125

See O.D. Specifications

Heater KitModel Used

JAYHTR1A05BKR*

Electric Heat (kW)

Min. Circuit Ampacity Max. Fuse or Breaker(HACR) Ampacity

Minimum Heating Blower Speed

240V 208V 208V240V Without HP With HP

JAYHTR1A08BKR*

JAYHTR1A10BKR*

5

7.5

10

28.1

41.1

54.1

24.6

35.9

47.2

30

45

60

25

40

50

Low

Low

Low

Low

Note: Factory set at Medium Speed.

Low Low

368576

339

467

190245

526

0.8(.20)

662

0.7(.17)

697

0.6(.15)

807

656

409

0.5( .12)

897

711

494

0.4(.10)

973

810

550

0.3(.07)

1022

865

619

0.2(.05)

1066

913

692

0.1(.02)

1107

958

743

High

Medium

Low

0(0)

CFM

CFM

CFM

.C. (kPa)External Static Pressure-Inches W

AIR FLOW PERFORMANCE

SpeedMotor J4AH4P24A1B00AA

Page 3: Trane Submittal 3 Ton Convertible Air Handler TAM4A0A36S31SA · 2021. 5. 11. · No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors — H.P. Motor Speed R ... 240V 208V 240V

The manufacturer has a policy of continuous product and product data improve-ment and it reserves the right to change design and specification without notice.

Mechanical Specifications

• Unique Cabinet Design- Metal shell and glass cotton thermal insulation layer• Multi-Position UP/Down Flow Horizontal Left /Right• Braze in Refrigerant Connection• Primary/Secondary Condensate Connections• Blower with Integrated Slide Deck for Easy Removal• Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal

• More auxiliary Electric Heaters optional• PSC 3 Speed Motor• High Efficiency• Integrated Horizontal Drain pans and metal Vertical Drain• Fused 24V Power• Suitable for Manufactured/Mobile Home Use.

BX-PRQ-J4AH4P24A1B00A-1A