Trane Product Data - Upflow/Horizontal Left, Downflow ...
Transcript of Trane Product Data - Upflow/Horizontal Left, Downflow ...
XV 95TUH2B060A9V3VBTUH2B080A9V3VBTUH2B080A9V4VBTUH2C100A9V4VB TUH2C100A9V5VBTUH2D120A9V5VB
PUB. NO. 22-1814-11
Upflow/ Horizontal Left,Downflow/ Horizontal Right Variable SpeedTwo Stage CondensingGas-Fired Furnace
UPFLOW
*UH-A9V-V
UPFLOW/HORIZONTAL
*DH-A9V-V
DOWNFLOW
DOWNFLOW/HORIZONTAL
Direct Vent withVariable Speed BlowerVariable Speed Inducer
TDH2B060A9V3VBTDH2B080A9V3VBTDH2B080A9V4VBTDH2C100A9V4VBTDH2D120A9V5VB
2 Pub. No. 22-1814-11
GeneralFeatures
© 2013 Trane All Rights Reserved
NATURAL GAS MODELSCentral Heating furnace designs are certified by the American Gas Associa-tion for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide addi-tional safety.
QUICK HEATINGDurable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to in-crease efficiency and provide a positive discharge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains con-nection points for E.A.C./Humidifier.
ENERGY EFFICIENT OPERATIONFurnace is certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized to .5” water column with all inlets, outlets, and drains sealed.
AIR DELIVERYThe variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
SECONDARY HEAT EXCHANGERThe XV95 has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost instead.
STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision.
FEATURES AND GENERAL OPERATIONThe XV95 High Efficiency Gas Fur-naces utilize an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service ac-cess.
a. Low energy power venter b. Vent proving pressure switch.
3Pub. No. 22-1814-11
Contents
General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3VBTUH2B080A9V3VBTUH2B080A9V4VBTUH2C100A9V4VBTUH2C100A9V5VBTUH2D120A9V5VBTDH2B060A9V3VBTDH2B080A9V3VBTDH2B080A9V4VBTDH2C100A9V4VBTDH2D120A9V5VB
Performance Data 9-19 Venting Table 20 Electrical Data 21-24 Field Wiring 25-26 Dimensions 27-28
4 Pub. No. 22-1814-11
XV 95 STANDARD EQUIPMENT
Featuresand Benefits
• Lite Port™ extended system diag-nostics
• Stored fault code history in micro pro-cessor nonvocatile memory
• Cleanable high velocity filters (upflow only)
• Hinged blower door *
• Perfect fit door latches*
• Insulated blower door*
• Gasketed blower door*• Complete front service access• Left/right gas connection• Adjustable fan off times• Optional L.P conversion kit• Selectable cooling fan off delay
eliminates need for BAY24X045 time delay kit
• Variable Speed Blower Motor • Silicon Nitride Igniter with adaptive
heat up• Variable speed induced draft blower• Direct/Non-Direct vent option• Fused 24 volt control circuit• Manual reset burner safety switches• Power supply 115/1/60• Convertible to horizontal on left side• 2-stage gas valve• PVC venting-1 or 2 pipe option• Accessory hook-up capability• Integrated solid state control with self-
diagnostics• Attractive color accents • Heavy gauge aluminized steel heat
exchanger• Multi-port In-shot burners• Quiet induced draft blower
* (Upflow only)
5Pub. No. 22-1814-11
Featuresand Benefits
XV 95 OPTIONAL EQUIPMENT
Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... TAYSTAT241 [ ]Thermostat, Media Programmable 2-Stage Heating ..............................................................................................TAYSTAT302C [ ]Thermostat, Mechanical Heating Only With Fan Switch .........................................................................................TAYSTAT303C [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ..............................................................................AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................BAYSTAT305 [ ]Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling ...................................................................TAYSTAT300C [ ]Propane Conversion Kit ........................................................................................................................................ BAYLPKT210A [ ]Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ........................................................... TFM145A9FR0 [ ]Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ........................................................... TFM175A9FR0 [ ]Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................. TFM210A9FR0 [ ]Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ........................................................... TFM245A9FR0 [ ] Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ....................................................TFP145A9FR0 [ ]Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ....................................................TFP175A9FR0 [ ]Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...........................................................TFP210A9FR0 [ ]Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ....................................................TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ......................................................................................................... BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ....................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ....................................................................................................... BAYCLE24A2430A [ ]Downflow Subbase ................................................................................................................................................. BAYBASE205 [ ]Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]Filter Kit/Horizontal Conversion TUH2-060,080 ....................................................................................................... BAYFLTR203 [ ]Filter Kit/Horizontal Conversion TUH2-100 .............................................................................................................. BAYFLTR204 [ ]Filter Kit/Horizontal Conversion TUH2-120 .............................................................................................................. BAYFLTR205 [ ]High Altitude Pressure Switch Kit TUH2-060 ............................................................................................ BAYSWT10AHALTA1 [ ]High Altitude Pressure Switch Kit TUH2-080,100,120 .............................................................................. BAYSWT08AHALTA1 [ ]Concentric Vent Kit TUH2 Furnaces ...............................................................................................................BAYAIR30AVENTA [ ]Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces ............................................................................BAYVENT200B [ ]Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces ........................................................................BAYMFGH100A [ ]Cleanable Filter (14.5"/17.5" wide Upflow models) .................................................................................................. BAYFLTR317 [ ]Cleanable Filter (21" wide Upflow models) .............................................................................................................. BAYFLTR321 [ ]Cleanable Filter (24.5" wide Upflow models) ........................................................................................................... BAYFLTR324 [ ]CleanEffects™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace) ........................................... TFD145ALFR000B [ ]CleanEffects™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ...........................................TFD175ALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) ..................................................TFD210ALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ...........................................TFD245ALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) ...................................... TFD14DALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) ...................................... TFD17DALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) ............................................ TFD21DALFR000B [ ] CleanEffects™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) ...................................... TFD24DALFR000B [ ] CleanEffects™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners) ..................................... BAYTRANS12024 [ ]
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
6 Pub. No. 22-1814-11
GeneralData
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Energy Star
TUH2 PRODUCT SPECIFICATIONS1
Product Specifications 1
MODELTYPERATINGS 21st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzFLACOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
TUH2B080A9V3VB 5Upflow / Horizontal
52,00050,44080,00077,600
9735 - 65
DIRECT10 x 8
1Variable
See Fan Performance Table1/2
Variable115/1/60
7.7Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
4115/1/60
10.8151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
168 / 156
TUH2B060A9V3VB 5Upflow / Horizontal
39,00037,83060,00058,200
9735 - 65
DIRECT10 x 8
1Variable
See Fan Performance Table1/2
Variable115/1/60
7.7Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
3115/1/60
10.8151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
158 / 146
TUH2C100A9V4VB 5Upflow / Horizontal
65,00062,855100,00096,70096.7
35 - 65DIRECT10 x 10
1Variable
See Fan Performance Table3/4
Variable115/1/60
9.6Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
5115/1/60
13.2151/2
H x W x D41-3/4 x 23 x 30-1/2
197 / 185
TUH2B080A9V4VB 5Upflow / Horizontal
52,00050,44080,00077,600
9735 - 65
DIRECT11 x 8
1Variable
See Fan Performance Table3/4
Variable115/1/60
9.6Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
4115/1/60
13.2151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
170 / 158
7Pub. No. 22-1814-11
PRODUCT SPECIFICATIONS 1
MODELTYPERATINGS 21st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzFLACOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
TUH2/TDH2 PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Energy Star
TUH2D120A9V5VB 5Upflow / Horizontal
78,00075,426120,000116,040
96.740 - 70
DIRECT10 x 10
1Variable
See Fan Performance Table1
Variable115/1/60
12.8Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 24x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
6115/1/60
17.2201/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
206 / 193
TDH2B080A9V3VB 5Downflow / Horizontal
52,00049,40080,00076,000
9635 - 65
DIRECT10 x 8
1Variable
See Fan Performance Table1/2
Variable115/1/60
7.7Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
4115/1/60
10.8151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
168 / 158
TDH2B060A9V3VB 5Downflow / Horizontal
39,00037,00060,00057,000
9635 - 65
DIRECT10 x 8
1Variable
See Fan Performance Table1/2
Variable115/1/60
7.7Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
3115/1/60
10.8151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
160/ 146
TUH2C100A9V5VB 5Upflow / Horizontal
65,00062,855100,00096,70096.7
35 - 65DIRECT11 x 10
1Variable
See Fan Performance Table1
Variable115/1/60
12.8Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
5115/1/60
17.2201/2
H x W x D41-3/4 x 23 x 30-1/2
199 / 187
8 Pub. No. 22-1814-11
PRODUCT SPECIFICATIONS 1
MODELTYPERATINGS 21st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzFLACOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
TDH2D120A9V5VB5Downflow / Horizontal
78,00074,000120,000114,000
9640 - 70
DIRECT10 x 10
1Variable
See Fan Performance Table1
Variable115/1/60
12.8Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity2 - 16x20 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
6115/1/60
17.2201/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
206 / 196
TDH2C100A9V4VB 5Downflow / Horizontal
65,00061,750100,00095,000
9635 - 65
DIRECT10 x 10
1Variable
See Fan Performance Table3/4
Variable115/1/60
9.6Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity2 - 16x20 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
5115/1/60
13.2151/2
H x W x D41-3/4 x 23 x 30-1/2
185 / 175
TDH2B080A9V4VB 5Downflow / Horizontal
52,00049,40080,00076,000
9535 - 65
DIRECT11 x 8
1Variable
See Fan Performance Table3/4
Variable115/1/60
9.6Centrifugal
Direct - Variable1/50 - 5000
33 - 110/3/60 - 1801.0Yes
High Velocity2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface IgniterMultiport Inshot
4115/1/60
13.2151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
172 / 160
GeneralData
TDH2 PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Energy Star
9Pub. No. 22-1814-11
*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS575 65
575 90
575 125
550155 -
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS640 70
640 110
640 140
630 175 -
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS700 85
700 125
700 160
700 200 -
2.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS700100
700130
700170
700210 -
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS800115
800155
800200
800250 -
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS900140
900195
900240
900290 -
2.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS875130
875180
875230
875270 -
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1000175
1000235
1000285
1000335
900310
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1125235
1125295
1125345
1100370
925318
3
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1050195
1050260
1050305
1050350
920315
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1200275
1200330
1200385
1100385
940330
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1325360
1325425
1300460
1175425
1000365
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 2nd Stage Capacity =
37,83058,200
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
6005785
60057110
60057155
60057190
-
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
7004990
70049130
70049175
70049210
-
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
77544105
77544155
77544195
77544240
-
HIGH OFF OFFCFM
TEMP. RISEWATTS
87039135
87039185
87039235
87039290
-
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
86061140
92057200
92057245
92057300
67079245
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
100053190
100053255
100053305
100053340
70075255
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
112547250
112547315
112547370
102551355
77568285
HIGH OFF OFFCFM
TEMP. RISEWATTS
125042340
125042405
125042445
110048390
100053355
NOTES: * First letter may be "A" or "T" ** Factory setting
10Pub. No. 22-1814-11
*UH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 2nd Stage Capacity =
50,440 77,600
AIRFLOW SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80056105
80056140
80056180
80056220
80056265
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
86052115
88051165
89050215
92048265
91049320
NORMAL ** ON OFF
CFMTEMP. RISE
WATTS
96046150
99045200
100044230
102044310
101044350
HIGH OFF OFFCFM
TEMP. RISEWATTS
108041195
111040255
112040315
112040365
108041390
HEATING2ND
STAGE
LOW ON ON CFMTEMP. RISE
WATTS
110062205
110062260
112061320
112061370
109063400
MEDIUM LOW OFF ON CFMTEMP. RISE
WATTS
121057265
124055340
126054410
126054470
113061430
NORMAL ** ON OFF CFMTEMP. RISE
WATTS
136050365
139049445
140049500
136050535
121057475
HIGH OFF OFFCFM
TEMP. RISEWATTS
136050355
139049450
140049520
135051535
118058465
NOTES: * First letter may be "A" or "T" ** Factory setting
*UH2B080A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.0
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS75084
750122
750154
720185
710221
NORMAL (400 CFM/TON) ON ON OFF OFF CFM
WATTS840109
840146
840181
840226
820264
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS940136
940177
940215
940274
940318
2.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS850113
850150
870200
890250
890295
NORMAL (400 CFM/TON) OFF ON OFF OFF CFM
WATTS960150
990200
1000230
1020305
1010350
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1080195
1110255
1120315
1120365
1080390
3.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1020175
1020225
1040280
1050330
1050375
NORMAL (400 CFM/TON) ON OFF OFF OFF CFM
WATTS1170240
1180300
1200365
1200415
1130420
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1290310
1320410
1350470
1340520
1150440
3.5
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1170250
1190315
1210370
1210435
1100405
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1360365
1390445
1400500
1360535
1210475
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1360355
1390450
1400520
1350535
1180460
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
11Pub. No. 22-1814-11
*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 2nd Stage Capacity =
50,44077,600
AIRFLOW SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80056105
80056140
80056180
80056220
80056265
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
86052115
88051165
89050215
92048265
91049320
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
96046150
99045200
100044230
102044310
101044350
HIGH OFF OFFCFM
TEMP. RISEWATTS
108041195
111040255
112040315
112040365
108041390
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
110062205
110062260
112061320
112061370
109063400
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
121057265
124055340
126054410
126054470
113061430
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
136050365
139049445
140049500
136050535
121057475
HIGH OFF OFFCFM
TEMP. RISEWATTS
136050355
139049450
140049520
135051535
118058465
NOTES: * First letter may be "A" or "T" ** Factory setting
*UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS857107
849143
841179
833223
825266
NORMAL (400 CFM/TON) ON ON OFF OFF CFM
WATTS970158
971205
973251
966298
960345
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1082209
1093266
1104323
1099374
1095424
3.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1004153
1019210
1035267
1038321
1041374
NORMAL (400 CFM/TON) OFF ON OFF OFF CFM
WATTS1163249
1173311
1184372
1179426
1174480
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1323345
1328411
1332477
1320532
1307586
3.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1176254
1188317
1200380
1195437
1190494
NORMAL (400 CFM/TON) ON OFF OFF OFF CFM
WATTS1356379
1362446
1368514
1353568
1339623
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1536503
1536575
1536647
1512699
1488751
4.0
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1376374
1367429
1359483
1354547
1348611
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1562530
1562604
1563677
1531720
1499765
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1768757
1759830
1749902
1654866
1559829
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
12Pub. No. 22-1814-11
*UH2C100A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS80875
824125
840170
835210
830250
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS938100
963160
959205
964255
975310
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1058150
1100200
1121265
1136330
1142395
3.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1004120
1010175
1027230
1044285
1050345
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1141170
1190245
1214310
1229380
1234450
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1336250
1375330
1387410
1388480
1384545
3.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1153180
1206250
1230320
1239395
1244460
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1390285
1418465
1439445
1441515
1373540
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1575400
1606495
1632590
1596645
1445590
4.0
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1388290
1423360
1444440
1444515
1390540
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1610415
1641515
1666635
1607650
1449595
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1847630
1863735
1816780
1687720
1532665
NOTES: *First letter may be "A" or "T" 1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 2nd Stage Capacity =
62,855 96,700
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
87364100
89363145
90062195
89962240
90262290
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
97158115
99756
170
100656220
102255280
102954335
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
113649160
114649230
116548295
118047365
118447425
HIGH OFF OFFCFM
TEMP. RISEWATTS
125844225
129843300
131942390
132842450
128644490
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
126068213
130466305
132965380
133465460
131765510
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
146459315
147159
405
147858485
147858560
135064540
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
163153450
167851570
169051670
157955645
141961585
HIGH OFF OFFCFM
TEMP. RISEWATTS
184647640
186746760
179448770
164452700
149857650
NOTES: * First letter may be "A" or "T" ** Factory setting
13Pub. No. 22-1814-11
*UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER1st Stage Capacity =
2nd Stage Capacity =62,85596,700
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
87364100
89363145
90062195
89962240
90262290
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
97158115
99756170
100656220
102255280
102954335
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
113649160
114649230
116548295
118047365
118447425
HIGH OFF OFFCFM
TEMP. RISEWATTS
125844225
129843300
131942390
132842450
128644490
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
126068213
130466305
132965380
133465460
131765510
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
146459315
147159405
147858485
147858560
135064540
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
163153450
167851570
169051670
157955645
141961585
HIGH OFF OFFCFM
TEMP. RISEWATTS
184647640
186746760
179448770
164452700
149857650
NOTES: * First letter may be "A" or "T" ** Factory setting
*UH2C100A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1163222
1201304
1209375
1200433
1199495
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1339331
1365400
1366477
1377555
1382636
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1515440
1538535
1549620
1553708
1547796
4.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1339331
1365400
1366477
1377555
1382636
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1550471
1562550
1574645
1575733
1564813
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1744626
1758736
1770838
1772935
17601018
5.0
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1695578
1709728
1721820
1772930
17111007
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1919862
1919958
19051043
18311043
1709982
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTSNANA
NANA
NANA
NANA
NANA
NOTES: *First letter may be "A" or "T" 1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 3. NA = Not allowed.
14Pub. No. 22-1814-11
*UH2D120A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1210220
1210270
1220325
1230400
1230445
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1400305
1440390
1450465
1450510
1410560
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1590425
1600520
1610600
1600645
1380575
4.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1390305
1400375
1430445
1440515
1420565
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1620420
1650530
1670595
1640660
1480600
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1840600
1830690
1820765
1670700
1490620
5
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1800570
1780630
1780705
1700695
1530615
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS2050845
2010875
1860805
1710735
1530655
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS2160995
2040935
1920875
1780805
1620730
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 2nd Stage Capacity =
75,426 116,040
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
109062165
112060225
108063270
107063310
101067
380
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
121056220
120056280
120056330
118057395
116058
455
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
134050295
136050350
137049425
138049495
133051
535
HIGH OFF OFFCFM
TEMP. RISEWATTS
143047390
157043490
158043565
157043625
139049
565
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
166063485
169062590
168062640
164064675
146072
600
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
187056675
187056745
181058770
168062715
149070
625
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
206051880
199053890
185057810
171061750
153068
665
HIGH OFF OFFCFM
TEMP. RISEWATTS
220048
1030
209050965
194054895
179058830
164064
750
NOTES: * First letter may be "A" or "T" ** Factory setting
15Pub. No. 22-1814-11
*DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER1st STAGE CAPACITY =
2nd STAGE CAPACITY =37,44057,600
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
6005655
6005685
60056120
60056150
60056185
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
6755065
67550105
67550140
67550175
67550205
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
7504585
75045125
75045160
75045210
75045260
HIGH OFF OFFCFM
TEMP. RISEWATTS
85040115
85040155
85040205
85040260
85040320
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
90058125
90058165
90058220
90058270
90058315
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
100052170
105050230
105050295
105050335
105050370
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
110047215
115045285
115045340
115045395
110047440
HIGH OFF OFFCFM
TEMP. RISEWATTS
130040330
132539385
132539455
125042465
120043470
NOTES: * First letter may be "A" or "T" ** Factory setting
*DH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS52545
52570
525100
525135
525160
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS60055
60085
600120
600150
600185
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS67565
675105
625140
675175
675205
2.0
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS70070
700115
700145
700185
700220
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS800100
800135
800175
800225
800280
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS900125
900165
900220
900270
900330
2.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS875115
875160
875210
875260
875310
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1000150
1000207
1000265
1000320
1000380
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1125215
1125285
1125340
1125395
1125440
3
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1050175
1050240
1050305
1050345
1050380
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1200240
1200315
1200385
1200440
1100410
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1350330
1350410
1350500
1275485
1170450
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
16Pub. No. 22-1814-11
*DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.0
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS70095
700105
700115
680200
670235
NORMAL (400 CFM/TON) ON ON OFF OFF CFM
WATTS800130
800160
800205
790245
740265
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS900160
900215
900255
900300
750270
2.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS875145
875185
875240
875280
760270
NORMAL (400 CFM/TON) OFF ON OFF OFF CFM
WATTS1000205
1000265
1000310
1000340
800295
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1150295
1150340
1150385
1020350
800300
3.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1050235
1050295
1050340
1010350
800290
NORMAL (400 CFM/TON) ON OFF OFF OFF CFM
WATTS1200335
1200385
1200410
1040365
840310
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1350455
1350480
1210435
1070390
900345
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY =2nd STAGE CAPACITY =
49,92076,800
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80056130
80056170
80056210
79056245
-
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
90049162
90049210
90049260
90049295
-
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
100044205
100044265
100044310
100044345
80056295
HIGH OFF OFFCFM
TEMP. RISEWATTS
117038305
117038350
117038400
102044360
83054310
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
115060285
115060345
115060385
102067***360
83083***305
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
127554380
127554445
120057425
104066***380
90076***350
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
143048515
134051490
122056455
109063410
93074***380
HIGH OFF OFFCFM
TEMP. RISEWATTS
143048515
134051490
122056455
109063410
93074***380
NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX Temperature change value
17Pub. No. 22-1814-11
*DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER1st STAGE CAPACITY =
2nd STAGE CAPACITY =49,40076,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80056130
80056170
80056210
79056245
-
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
90049162
90049210
90049260
90049295
-
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
100044205
100044265
100044310
100044345
80056295
HIGH OFF OFFCFM
TEMP. RISEWATTS
117038305
117038350
117038400
102044360
83054310
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
115060285
115060345
115060385
102067***360
83083***305
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
127554380
127554445
120057425
104066***380
90076***350
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
143048515
134051490
122056455
109063410
93074***380
HIGH OFF OFFCFM
TEMP. RISEWATTS
143048515
134051490
122056455
109063410
93074***380
NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX Temperature change value
*DH2B080A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS849141
865191
881241
878294
876348
NORMAL (400 CFM/TON) ON ON OFF OFF CFM
WATTS953195
965250
977305
973358
970411
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1057249
1065309
1073369
1069422
1064474
3.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS999188
1003241
1008394
1018354
1029414
NORMAL (400 CFM/TON) OFF ON OFF OFF CFM
WATTS1144300
1150362
1156423
1160486
1165548
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1288412
1297482
1305552
1303617
1300682
3.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1156307
1165374
1174440
1177502
1179563
NORMAL (400 CFM/TON) ON OFF OFF OFF CFM
WATTS1327446
1335518
1343589
1325641
1307693
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1506634
1502703
1498771
1418746
1338721
4.0
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1327446
1335518
1343589
1325641
1307693
NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1525656
1522727
1518797
1430761
1341725
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1706906
1635881
1563857
1471813
1379769
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
18Pub. No. 22-1814-11
*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER1st STAGE CAPACITY =
2nd STAGE CAPACITY =62,40096,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
92361
110
95559
165
96058210
95858265
94759310
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
102055
145
104753
190
105353250
104254295
102954350
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
115648
185
116648
240
117248300
117748350
117848420
HIGH OFF OFFCFM
TEMP. RISEWATTS
127544
225
130543
290
132842365
132842445
132842510
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
129866
235
132065
305
133565380
134364445
134364520
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
143960
310
145959
390
148258470
148358550
147059610
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
163953
430
165052
525
165052600
164452680
149658640
HIGH OFF OFFCFM
TEMP. RISEWATTS
179018
570
181847
670
181347770
170850750
153556675
NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX temperature change
*DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON)
ON ON OFF ONCFM
WATTS870100
885140
887185
881230
876270
NORMAL(400 CFM/TON)
ON ON OFF OFFCFM
WATTS989120
1018180
1016230
1012285
999325
HIGH(450 CFM/TON)
ON ON ON OFFCFM
WATTS1124175
1139225
1130275
1135335
1135390
3.0
LOW(350 CFM/TON)
OFF ON OFF ONCFM
WATTS1053145
1075200
1070245
1070295
1049350
NORMAL(400 CFM/TON)
OFF ON OFF OFFCFM
WATTS1186195
1205255
1220310
1220370
1216440
HIGH(450 CFM/TON)
OFF ON ON OFFCFM
WATTS1336255
1366340
1383405
1385470
1381545
3.5
LOW(350 CFM/TON)
ON OFF OFF ONCFM
WATTS1216190
1225255
1235320
1240385
1243445
NORMAL(400 CFM/TON)
ON OFF OFF OFFCFM
WATTS1394270
1422360
1436430
1437505
1430580
HIGH(450 CFM/TON)
ON OFF ON OFFCFM
WATTS1579395
1604475
1610555
1599645
1517640
4.0 LOW(350 CFM/TON)
OFF OFF OFF ONCFM
WATTS1377270
1412355
1426430
1433510
1428575
NORMAL(400 CFM/TON)
OFF OFF OFF OFFCFM
WATTS1599425
1624510
1636585
1618670
1512635
HIGH(450 CFM/TON)
OFF OFF ON OFFCFM
WATTS1801580
1818690
1815775
1694735
1525660
NOTES: * - First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
19Pub. No. 22-1814-11
*DH2D120A9V5V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY =2nd STAGE CAPACITY =
74,880115,200
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURESW 8 SW 7 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
102565150
102565200
100067240
100067290
100067340
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
120056230
120056270
120056330
120056390
120056450
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
135049280
135049340
135049490
135049470
135049530
HIGH OFF OFFCFM
TEMP. RISEWATTS
155043400
155043
490
155043560
155043620
145046600
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
155066380
155066470
155066540
155066610
145071***690
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
185056660
185056750
185056780
170060720
150069640
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
205050860
200051880
185056810
170060750
155066670
HIGH OFF OFFCFM
TEMP. RISEWATTS
210549
1000
205050940
190054880
177558820
162563750
NOTES: * First letter may be "A" or "T" ** Factory setting
*DH2D120A9V5V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1225240
1225280
1225340
1225400
1225450
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1400310
1400390
1400470
1400520
1400570
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1600450
1600520
1600590
1600640
1450600
4.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1400300
1400380
1400450
1400520
1400570
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1600460
1600530
1600610
1600670
1450600
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1800610
1800700
1800760
1650690
1500630
5
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1750580
1750640
1750720
1650680
1450610
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS2000830
2000860
1850800
1700740
1550660
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS2100970
2000910
1900850
1650780
1600710
NOTES: * - First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
20 Pub. No. 22-1814-11
Maximum Vent Length Table
VENT LENGTH TABLE
ALTITUDE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEETFOR VENT AND INLET AIR (SEE NOTES)
0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE
*UH/DH2B060A9V3VB 200 200 200
*UH/DH2B080A9V3VB *UH/DH2B080A9V4VB
50 120 200
*UH/DH2C100A9V4VB *UH2C100A9V5VB
Not Allowed 60 200
*UH/DH2D120A9V5VB Not Allowed Not Allowed 200
7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE
*UH/DH2B060A9V3VB 100 100 100
*UH/DH2B080A9V3VB *UH/DH2B080A9V4VB
25 60 100
*UH/DH2C100A9V4VB *UH2C100A9V5VB
Not Allowed 30 100
*UH/DH2D120A9V5VB Not Allowed Not Allowed 100
9,500-12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE
*UH/DH2B060A9V3VB 50 50 50
*UH/DH2B080A9V3VB *UH/DH2B080A9V4VB
Not Allowed 30 50
*UH/DH2C100A9V4VB *UH2C100A9V5VB
Not Allowed Not Allowed 50
*UH/DH2D120A9V5VB Not Allowed Not Allowed 50
NOTES: * - First letter may be "A" or "T"1. Minimum vent length for all models: 3' horizontal or 3' vertical.2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapt-ers at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe.3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).4. One SHORT radius 90° elbow is equivalent to 10' of 3" or 4" pipe and one LONG radius elbow is equivalent to 6' of 3" or 4" pipe. One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet. 6. Pipe adapters are field supplied (except for the *UH/DH2D120 models).7. For Canadian applications ONLY, IPEX 196006 may be used for horizontal and vertical terminations. IPEX 081216, IPEX 081218, and IPEX 081219 may only be used for horizontal vent terminations. Equivalent lengths are IPEX 196009 = 5 feet, IPEX 081216 = 11 feet, IPEX 081218 = 16 feet, and IPEX 081219 = 21 feet
25Pub. No. 22-1814-11
Field Wiring
1. Be sure power agrees with equipment nameplates. 2. Low voltage (24 volt wiring) to be No. 18 A.W.G. min. 3. Grounding of equipment must comply with local codes. 4. Set thermostat heat anticipator per unit wiring diagram. 5. These leads provide 115V. power for connection of electronic
air cleaner and humidifier MAX. load 1.0 amps each. 6. When a single stage heating thermostat without fan switch
is used, no wiring on "G" terminal is used. 7. W1 and W2 must be jumpered together for proper operation.
Second stage heat will begin based on IFC switch setting. 8. Set dip switches with power off per installation instructions
to set airflow and indoor fan off delays. 9. Continuous fan airflow can be increased by adding this jumper. 10. This wire is only for thermostats requiring connection to
transformer common terminal. 11. Optional humidistat is to be connected between R and BK. Factory installed jumper R
to BK on the circuit board must be cut if optional humidistat is used. The jumper must also be cut when applying an airflow command signal to the BK input such as with the variable speed single-zone and multi-zone system controllers. On single speed cooling only/non-heat pump systems, jumper Y to O for proper operation of the delay profiles and the humidistat. For two compressor or two speed systems, jumper YLo to O.
W14
SEE NOTE 10
SEE NOTE 9
Y1/Ylo
W14 JUMPERSEE NOTE 11
FIELD ADDED JUMPER W1 TO W2.
SEE FURNACE WIRING DIAGRAM FOR 2ND STAGE TIMING.
From Dwg. B342027 Rev. 1
SEE NOTE 6
B/C B/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE1 STAGE HEATING
USING A 1 STAGE HEATING THERMOSTATNO COOLING
Figure 60
26 Pub. No. 22-1814-11
Field Wiring
1. Be sure power agrees with equipment nameplates.2. Low voltage (24 volt wiring) to be No. 18 A.W.G. min.3. Grounding of equipment must comply with local codes.4. Set thermostat heat anticipator per unit wiring diagram.5. These leads provide 115V. power for connection of electronic
air cleaner and humidifier MAX. load 1.0 amps each.6. This wire is only for thermostats requiring connection to
transformer common terminal.7. Continuous fan airflow can be increased by adding this jumper.8. Set dip switches with power off per installation instructions
to set airflow and indoor fan off delays.9. Optional humidistat is to be connected between R and BK. Factory
installed jumper R to BK on the circuit board must be cut if optionalhumidistat is used. The jumper must also be cut when applying an airflowcommand signal to the BK input such as with the variable speed single-zoneand multi-zone system controllers. On single speed cooling only/non-heat pumpsystems, jumper Y to O for proper operation of the delay profiles and the humidistat.For two compressor or two speed systems, jumper YLo to O.
W14
SEE NOTE 6
From Dwg. B342025 Rev. 0
Y1/Ylo
W14 JUMPERSEE NOTE 9
SEE NOTE 7
B/C B/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE2 STAGE HEATING
USING A 2 STAGE HEATING THERMOSTATNO COOLING
Figure 61
27Pub. No. 22-1814-11
Field Wiring
W14
OUTDOOR UNIT (NO TRANSFORMER)
SEE NOTE 6
SEE NOTE 7
From Dwg. B342022 Rev. 1
Y1/Ylo
W14 JUMPERSEE NOTE 9
B/CB/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING
USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)
FIELD ADDED JUMPER W1 TO W2.
SEE FURNACE WIRING DIAGRAM FOR 2ND STAGE TIMING.
Figure 62
28 Pub. No. 22-1814-11
Field Wiring
W14
OUTDOOR UNIT (NO TRANSFORMER)
SEE NOTE 6
SEE NOTE 7
Y1/Ylo
SEE NOTE 9
W14 JUMPERSEE NOTE 9
From Dwg. B342020 Rev. 0
B/CB/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE2 STAGE HEATING, 1 STAGE COOLING
USING A 2 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)
Figure 63
29Pub. No. 22-1814-11
Field Wiring
BLK/TWIN W2 W1 R G B Y YLO O
BLK/TWIN
BK JUMPERW14
W2 W1 R G B Y YLO O
OFF
1
21
2
ON
HUMIDISTAT HOOKUPIf an optional Humidistat is to be connected between “R” and “BK”, the factory installed jumper between “R” and “BK” on the circuit board must be cut. If an optional Humidistat is used, the jumper must also be cut when applying an airflow com-mand signal to the “BK” input such as with the variable speed single-zone and multi-zone system controller. On single speed cooling only/ non-heat pump systems, jumper “Y” to “O” for proper operation of the delay profiles and the Humidistat. For two compressor or two speed systems, jumper “YLO” to “O”.
Figure 64
The factory installed jumper be-tween “R” and “BK” on the circuit board must be cut if an optional Humidistat is installed.
Figure 65
OUTDOOR UNIT(NO TRANSFORMER)
SEE NOTE 6
SEE NOTE 7
W14R-BK
JUMPERSEE NOTE 9
B/CB
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE2 STAGE HEATING, 2 STEP STAGED COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
30 Pub. No. 22-1814-11
Dimensions
*UH
2 U
PF
LO
W / H
OR
IZO
NTA
L O
UT
LIN
E D
RA
WIN
G(A
LL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
31Pub. No. 22-1814-11
*DH
2 D
OW
NF
LO
W / H
OR
IZO
NTA
L O
UT
LIN
E D
RA
WIN
G(A
LL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
Dimensions