Tozzi electrical equipment template v1 4-3

51
COMPANY PROFILE WE FEED WHAT YOU NEED WE FEED WHAT YOU NEED Riccardo Ardemani Piacenza, 2014

Transcript of Tozzi electrical equipment template v1 4-3

Page 1: Tozzi electrical equipment template v1 4-3

COMPANY PROFILEWE FEED WHAT YOU NEEDWE FEED WHAT YOU NEED

Riccardo Ardemani

Piacenza, 2014

Page 2: Tozzi electrical equipment template v1 4-3

THE FACTORYTHE FACTORY

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 3: Tozzi electrical equipment template v1 4-3

ORGANIZATION CHARTORGANIZATION CHART

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 4: Tozzi electrical equipment template v1 4-3

CONTACTS

H d t Vi Z h ifi i 10 48123

CONTACTS

Headquarters: Via Zuccherificio 10, 48123 Mezzano, Ravenna, Italy.Phone +39 0544 525022 Fax +39 0544 [email protected]

Commercial Department: Via Kennedy 24,20097, San Donato Milanese, Milano, ItalyPhone +39 02 51621243 Fax +39 02 51621417 [email protected]

Factory: SS 16 Zona Ind.le Incoronata 71122Foggia, Italy.Phone +39 0881 811411 Fax +39 0881 [email protected]

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 5: Tozzi electrical equipment template v1 4-3

MISSIONMISSION

Engineering, manufacturing and sale of L.V. and M.V switchgears and apparatus, IMCS system and prefabricated Modular Substation as detailed below:Modular Substation, as detailed below:

ECOSMART PBSF6 gas insulated switch-disconnector

ECOSMART VCB L & FVacuum circuit breaker

QMTCArc proof air insulated medium voltage switchgear for primary distributionp g g p y

ECOSMART MIXAir insulated medium voltage switchgear for secondary distribution

ECOSMART GISECOSMART GISSF6 gas insulated medium voltage switchgear for secondary distribution

QMM90NLow voltage main distribution switchgear and motor control center

INTEGRATED MONITORING & CONTROL SYSTEM (IMCS)

PREFABRICATED MODULAR SUBSTATIONS

www.tozziholding.comApril 2014Tozzi Ielectrical Equipment / Company Profile

Page 6: Tozzi electrical equipment template v1 4-3

QUALITY MANAGEMENT SYSTEMQUALITY MANAGEMENT SYSTEM

TOZZI ELECTRICAL EQUIPMENT IS CERTIFIED ISO 9001-2008

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 7: Tozzi electrical equipment template v1 4-3

QUALITY MANAGEMENT SYSTEMQUALITY MANAGEMENT SYSTEM

TOZZI ELECTRICAL EQUIPMENT IS CERTIFIED ISO 14001-2004

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 8: Tozzi electrical equipment template v1 4-3

THE FACTORYTHE FACTORY

Location S.S.16 Zona Industriale Incoronata –FOGGIA (Italy)

T t l A SQM 38 000Total Area SQM. 38.000

Built Area SQM. 10.000

Storage Area SQM. 1.400

Harbour Connection At 120 Kms (Bari)Harbour Connection At 120 Kms. (Bari)

Railway Connection At 8 Kms. Foggia Station (Milano-Lecce line)

S i h t Super Highway At 15 Kms. connection (Highway A14

Bologna-Bari)

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 9: Tozzi electrical equipment template v1 4-3

ASSEMBLY DEPARTMENTASSEMBLY DEPARTMENT

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 10: Tozzi electrical equipment template v1 4-3

Laser, Punching and cutting line

Bending and Moulding line

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 11: Tozzi electrical equipment template v1 4-3

Test and Inspection room

Treatment and Painting D t tDepartment

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 12: Tozzi electrical equipment template v1 4-3

MV SWITCHGEAR FOR PRIMARY DISTRIBUTION TYPE PRIMARY DISTRIBUTION TYPE QMTC

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 13: Tozzi electrical equipment template v1 4-3

MV SWITCHGEAR QMTC GENERAL FEATURES MV SWITCHGEAR QMTC GENERAL FEATURES

ARC PROOF AIR INSULATED SWITCHGEAR FOR PRIMARY DISTRIBUTION

Reference standards:a) IEC 62271-200 – A.C. Metal Enclosed Switchgearsb) IEC 62271-100 – Circuit Breakersc) IEC 60470 – Contactors d) IEC 62271-102 – Earthing Switche) DEP 33 67 51 31e) DEP 33.67.51.31General features:Loss of service continuity category: LSC2BPartition class: PMInternal Arc Classified (IAC): AFLRCircuit-breaker / contactor racking-in / out with closed doorC t ti ith d i i l i d h tConstruction with sendzimir pre-galvanized sheetsFully Type Tested in accordance with IEC 62271-200 and ANNEX AInternal separation partition: up to IP3X

www.tozziholding.com

p p p

Mese annoTozzi Electrical Equipment / Company Profile

Page 14: Tozzi electrical equipment template v1 4-3

MV SWITCHGEAR QMTC ELECTRICAL MV SWITCHGEAR QMTC ELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Industries / Titolo presentazione

Page 15: Tozzi electrical equipment template v1 4-3

MEDIUM VOLTAGE SWITCHGEAR QMTC

QMTC12

DETAILS - SIDE VIEW

Project QAFCO 5

Rated Voltage : 12kVRated Voltage : 12kVRated Current : 4000A with forced ventilationShort time withstand current : 50KA for 3 sec.Internal Arc fault : 50KA for 1 sec.

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 16: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS - QMTCMV SWITCHGEARS QMTC

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

QAFCO PROJECT - QATAR - 6,6 MV SWITCHGEARS

Page 17: Tozzi electrical equipment template v1 4-3

MV SWITCHGEAR QMTCMV SWITCHGEAR - QMTC

ENI REFINERY ITALY 6KV MV SWITCHGEAR DOUBLE BUS-BAR SYSTEM

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 18: Tozzi electrical equipment template v1 4-3

MV SWITCHGEAR QMTCMV SWITCHGEAR - QMTC

ENI REFINERY ITALY 6KV MOTOR CONTROL CENTER

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

ENI REFINERY ITALY - 6KV MOTOR CONTROL CENTER

Page 19: Tozzi electrical equipment template v1 4-3

AIR & SF6 GAS INSULATED

SERIES ECOSMART MIX &

AIR & SF6 GAS INSULATED MV SWITCHGEAR FOR SECONDARY DISTRIBUTION

SERIES ECOSMART MIX & ECOSMART GIS

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 20: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART MIX GENERAL FEATURESGENERAL FEATURES

MEDIUM VOLTAGE AIR INSULATED SWITCHGEAR FOR SECONDARY DISTRIBUTIONDISTRIBUTIONReference standards:a) IEC 62271-200 AC metal-enclosed switchgear and controlgear for rated

voltages above 1 kV and up to and including 52 Kv

b) IEC 62271-100 High-voltage switchgear and controlgear –Part 100: Alternating-current circuit-breakers

c) IEC 62271-102 High-voltage switchgear and controlgear –Part 102: Alternating current disconnectors and earthing switchesAlternating current disconnectors and earthing switches

d) IEC 62271-103 High-voltage switchgear and controlgear –Part 103: Switches for rated voltages above 1 kV up to and including 52 kV

) IEC 62271 105 Hi h lt it h d t l P t 105 e) IEC 62271-105 High-voltage switchgear and controlgear –Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

f) IEC 60255 Measuring relays and protection equipment –Part 1: Common requirementsrequirements

g) IEC 60529 Degrees of protection provided by enclosures (IP Code)

h) Loss of service continuity LSC2A-PM

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 21: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART MIXMV SWITCHGEARS ECOSMART MIXELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 22: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART MIX CUBICLES TYPESCUBICLES TYPES

ECOSMART MIX 12 24kVTYPOLOGIES DESCRIPTION 375 500 750

WIDTH mmTYPOLOGIES DESCRIPTION 375 500 750

L Cables riserB Busbars riser (Incoming)BE Busbar riser with earth switchBAV Busbar riser with CT and VT arrangementBAV Busbar riser with CT and VT arrangementS Switch disconnectorSA Switch disconnector and CT arrangementSB Switch disconnector and busbars riserSBM Switch disconnector busbars riser and CT/VT arrangementS Sw tc d sco ecto busba s se a d C /V a a ge e tFS Switch disconnector and fusesFSL Switch disconnector ,fuses, lateral cables outgoingMSF Measure Switch disconnector with fuses and VT arrangementCBS vacuum circuit breaker and disconnector CBSB Vacuum circuit breaker, Disconnector ,Busbars riser (bus tie) CBSA Vacuum circuit breaker, Disconnector, CTs arrangementCBSAB Vacuum circuit breaker, Disconnector ,CTs arrangemen, Busbars riser CB2SA Vacuum circuit breaker,Double disconnector , CT arrangementMFAV Metering with fuses, CT and VT arrangement (incoming/outgoing busbars)MAVL Metering with CT and VT arrangement (lateral incoming bottom outgoing)MAVD Metering with CT and VT arrangement (bottom incoming/outgoing)

www.tozziholding.comApril 2014Tozzi Industries / Titolo presentazione

Page 23: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART GIS GENERAL FEATURESGENERAL FEATURES

MEDIUM VOLTAGE SF6 GAS INSULATED SWITCHGEAR FOR SECONDARY DISTRIBUTIONSECONDARY DISTRIBUTIONReference standards:a) IEC 62271-200 AC metal-enclosed switchgear and controlgear for rated

voltages above 1 kV and up to and including 52 Kv

b) IEC 62271-100 High-voltage switchgear and controlgear –Part 100: Alternating-current circuit-breakers

c) IEC 62271-102 High-voltage switchgear and controlgear –Part 102: Alternating current disconnectors and earthing switchescurrent disconnectors and earthing switches

d) IEC 62271-103 High-voltage switchgear and controlgear –Part 103: Switches for rated voltages above 1 kV up to and including 52 kV

e) IEC 62271-105 High-voltage switchgear and controlgear –Part 105: Alternating e) IEC 62271 105 High voltage switchgear and controlgear Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 Kv

f) IEC 60255 Measuring relays and protection equipment –Part 1: Common requirementsq

g) IEC 60529 Degrees of protection provided by enclosures (IP Code)

h) Loss of service continuity LSC2A-PM

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 24: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART GISELECTRICAL FEATURESELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 25: Tozzi electrical equipment template v1 4-3

MV SWITCHGEARS ECOSMART GISCONFIGURATIONS TYPESCONFIGURATIONS TYPES

www.tozziholding.comMese annoTozzi Electrical Equipment / Company Profile

Page 26: Tozzi electrical equipment template v1 4-3

SERIES ECOSMART PB

SF6 GAS INSULATED MV SWITCH-DISCONNECTOR

SERIES ECOSMART PB

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 27: Tozzi electrical equipment template v1 4-3

MEDIUM VOLTAGE SF6 GAS INSULATED SWITCH-DISCONNECTOR FOR SECONDARY DISTRIBUTIONReference standards:a) IEC 62271-200 AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

b) IEC 62271-100 High-voltage switchgear and controlgear –Part 100: Alternating-current circuit-breakers

c) IEC 62271-102 High-voltage switchgear and controlgear –Part 102: c) IEC 62271 102 High voltage switchgear and controlgear Part 102: Alternating current disconnectors and earthing switches

d) IEC 62271-103 High-voltage switchgear and controlgear –Part 103: Switches for rated voltages above 1 kV up to and including 52 kV

e) IEC 62271-105 High-voltage switchgear and controlgear –Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

f) IEC 60255 Measuring relays and protection equipment –Part 1: Common requirements

g) IEC 60529 Degrees of protection provided by enclosures (IP Code)

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 28: Tozzi electrical equipment template v1 4-3

MV SWITCH-DISCONNECTOR ECOSMART PBELECTRICAL FEATURESELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 29: Tozzi electrical equipment template v1 4-3

SERIES ECOSMART VCB

MV VACUUM CIRCUIT BREAKER

L & ECOSMART VCB F

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 30: Tozzi electrical equipment template v1 4-3

MV VACUUM CIRCUIT BREAKER ECOSMART VCB L & VCB F GENERAL FEATURESVCB L & VCB F GENERAL FEATURES

MEDIUM VOLTAGE VACUUM CIRCUIT BREAKER FOR SECONDARY AND PRIMARY DISTRIBUTIONPRIMARY DISTRIBUTIONReference standards:IEC 62271-100 High-voltage switchgear and controlgear –Part 100: Alternating-current circuit-breakers

• Stored energy springs lateral or frontal operating mechanism (closing spring and opening spring)

• Manual and electrical operation

• Complete O-C-O cycle without reloading the springs

• Long mechanical and electrical life

• High number of operations• High number of operations

• Limited Maintenance

• Vacuum interrupters positioned inside the poles with protection against pollution, h idit i t d tihumidity, impacts, condensation

• Flexible in customization

• Large availability accessories range

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

• Easy installation

Page 31: Tozzi electrical equipment template v1 4-3

Fixed execution Withdrawable execution

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 32: Tozzi electrical equipment template v1 4-3

MV VACUUM CIRCUIT BREAKER ECOSMART VCB L ELECTRICAL FEATURESVCB L ELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 33: Tozzi electrical equipment template v1 4-3

MV VACUUM CIRCUIT BREAKER ECOSMART VCB F ELECTRICAL FEATURESVCB F ELECTRICAL FEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 34: Tozzi electrical equipment template v1 4-3

LV MAIN DISTRIBUTION SWITCHGEAR & MOTOR

TYPE QMM90N

SWITCHGEAR & MOTOR CONTROL CENTER

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 35: Tozzi electrical equipment template v1 4-3

LV SWITCHGEAR – QMM90N – GENERAL FEATURESFEATURES

ARC PROOF AIR INSULATED L.V. MOTOR CONTROL CENTER

Reference standards:

a) IEC 61439-1 (2009) – Low-Voltage switchgear and control gear assemblies

b) IEC 61641 (2008) – Arcing due to internal faultb) IEC 61641 (2008) Arcing due to internal fault

c) IEC 947 – Electrical components

d) DEP SHELL 33.67.01.31

General features:

Internal Arc Classified in accordance with IEC 61641

“Fault Free Zone”

The Arrangement of the switchboard are designed so that a

fault in this zone shall be virtual impossible under all conditions:- Main and vertical Bus-Bars fully insulated from the incoming terminals of the assembly up to the circuit protection inside the single outgoing functionalunit

- No live exposed part during the insertion of the withdrawable chassis- Internal separation: form 4b- Internal separation partition: up to IP4X

www.tozziholding.comMese annoTozzi Industries / Titolo presentazione

Page 36: Tozzi electrical equipment template v1 4-3

LV SWITCHGEARS – QMM90N – ELECTRICAL FEATURESFEATURES

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 37: Tozzi electrical equipment template v1 4-3

LV SWITCHGEARS – QMM90NLV SWITCHGEARS QMM90N

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

KUWAIT OIL COMPANY BS171 PROJECT LV SWITCHGEARS

Page 38: Tozzi electrical equipment template v1 4-3

INTEGRATED MONITORING&CONTROL

PLC SYSTEM PANELS

MONITORING&CONTROL SYSTEM

PLC SYSTEM PANELSSCADA SYSTEMLOAD SHEDDINGR.T.U.

SPECIAL PERFORMANCE BOARD

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 39: Tozzi electrical equipment template v1 4-3

ELECTRICAL CONTROL SYSTEMELECTRICAL CONTROL SYSTEM

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

POLSKIE LNG TERMINAL ESCS PANELS

Page 40: Tozzi electrical equipment template v1 4-3

PREFABRICATED

E-HOUSE

PREFABRICATED MODULAR SUBSTATION

LOCAL EQUIPMENT ROOMS (LER)POWER GENERATION MODULE (PGB)PROCESS UTILITY BUILDING (PUB)

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 41: Tozzi electrical equipment template v1 4-3

MODULAR SUBSTATIONSMODULAR SUBSTATIONS

ENEL MODULAR SUBSTATIONS FOR SECONDARY DISTRIBUTION

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 42: Tozzi electrical equipment template v1 4-3

MODULAR SUBSTATIONSMODULAR SUBSTATIONS

BUKIT TUA FPSO INDONESIAE-HOUSEE HOUSE

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 43: Tozzi electrical equipment template v1 4-3

Std IEC 62271 200 (2003 11)

MV SWITCHGEAR - QMTC12

Std. IEC 62271-200 (2003-11)

SHELL DEP. 33.67.51.31

Rated Voltage : 12kV

Rated Current : 3150A Natural ventilation

ISC : 50/125KAISC : 50/125KA

IAC : 50KA

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 44: Tozzi electrical equipment template v1 4-3

Std IEC 62271 200 (2003 11)

MV SWITCHGEAR - QMTC17

Std. IEC 62271-200 (2003-11)

SHELL DEP. 33.67.51.31

Rated Voltage : 17,5kV

Rated Current : 3600A

ISC : 50/125KA

IAC : 50KA

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 45: Tozzi electrical equipment template v1 4-3

TYPE TEST CERTIFICATESTYPE TEST CERTIFICATES

LV MOTOR CONTROL CENTER QMM90N

Std. IEC 61439-1 (2004)SHELL DEP. 33.67.01.31-Rated Voltage : 440V-Rated Current : 3200AISC : 100KA-ISC : 100KA

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 46: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 47: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 48: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comApril 2014Tozzi Industries / Titolo presentazione

Page 49: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comMese annoTozzi Electrical Equipment / Company Profile

Page 50: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile

Page 51: Tozzi electrical equipment template v1 4-3

MAIN REFERENCE LISTMAIN REFERENCE LIST

www.tozziholding.comApril 2014Tozzi Electrical Equipment / Company Profile