Tite-Loc PlusTechnical Information and Flashing Details
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-29351
PAC,PetersenAluminumCorporationreservestherighttodiscontinueproductsatanytimeorchangespecificationand/ordesignswithoutnoticeandwithoutincurringobligation.Applicationdetailsareforillustrationpurposesonly,andmaynotbeappropriateforallenvironmentalconditions,buildingdesigns,orpanelprofiles.Projectsshouldbeengineeredtoconformtoapplicablebuildingcodes,regulations,andacceptedindustrypractices.Descriptionsandspecificationscontainedhereinwereineffectatthetimethispublicationwasapprovedforprinting.PetersenAluminumCorporationdoesnotbuildordesignbuildings.Itactssolelyasasupplierofmaterials,andassumesnoresponsibilityfortheproperuseorinstallationofthosematerials,norforthesuitabilityofthosematerialsforanyspecificuseorforcompliancewithlocalbuildingcodes.
T i te-LocPlus Spec.Sheet
ULList Cards -ULConstruct ionNumbers437,616,617,263,790
ULConstruct ionCode&Miami-Dade/Flor idaApprovals
Tite-LocPlusFlashingDetai ls
SPEC-DATA®Sheet
MANUSPEC®Sheets
P AG E 2
P AG E S 3 - 7
P AG E 8
P A G E S 9 - 2 6
P AG E S 2 7 - 2 9
P AG E S 3 0 - 3 8
Product Information:
2
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
.032aluminum,,040aluminum,24ga.steel,or22ga.steel(Standardcolorsarelimitedin.040aluminumand22ga.steel)12”o.c.,16”o.c.,18”o.c.FactoryAppliedSealantBeaminSeamTensionLeveledAvailableSmooth,WithStriationsorPencilRibswithStriations
SolidSubstrate,OpenFramingorRigidInsulationVaporBarrier(onsolidsubstrateandrigidinsulation)Clips-LowFloat,Architectural,FixedorUtilityBearingPlates:Requiredwhenusedinassemblyincludingrigidinsulation overmetaldeckingMinimumRoofPitch:1/2”on12”
PAC-CLAD®(Kynar500®orHylar5000®)
ASTME331/1646andE283/1680
WhenaU.L.Ratingisrequired,PetersenAluminumCorporationmustbe
notifiedpriortofabricationofthepanels.
Tite-Loc Plus12”,16”or18”O.C. .032aluminum2”high .040aluminum 24gaugesteel 22gaugesteel
FACTORY APPLIED SEALANT
12", 16" or 18" O.C.
2"
Tite-Loc Plus
Features:
Requirements:
Finish:
Air&WaterInfiltrationTested:
Note:
U.L. Construction Numbers 437, 616, 617
Tite-LocPlusPanelscombinestructuralpanelperformancewitharchitecturalpanelaesthetics.Tite-LocPluspanels,field-seamedtoa180degreelock,carryaU.L.ratingoverawidevarietyofassembliesasindicatedbytheabovelistedU.L.Constructionnumbers.
Tite-L
oc P
lus
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-29353
UL
Co
nstr
uctio
n N
o.
43
7UL Construction No. 437Uplift - Class 90 / Fire Not Investigated
MetalRoofDeckPanels*/“Tite-LocPlus”No.24MSGmincoatedsteel,16in.max,12in.min.width,2in.highattheribs.Panelscontinuousovertwoormorespans.Endlapstooverlap6inches.Abeadofsealantmaybeusedatpanelendsandsidejoints.Sidelapstobetightenedandcrimpedwithanelectriccrimpingmachinetoa180degreeangle.Crimpingprocesstoincludetheupperportionofpanelclips(Item2).
RoofDeckFasteners*(PanelClips)Anyofthefollowing.Clipspacingtobe60in.OCmax.Sealantmaybeusedatthetopoftheclips:
Tite-LocPlusUtilityClip:Onepieceassembly;3in.wide,approximately2in.highwithtwoguideholesinbase.Fabricated fromNo.22MSGcoatedsteel. Tite-LocPlusLowFixedClip:Onepieceassembly;3in.wide,approximately2-3/8in.or3in.high,withthreeguideholesin base.FabricatedfromNo.22MSGcoatedsteel. Tite-LocPlusLowFloatingClip:Twopieceassembly;baseapproximately2in.wide,1-11/16in.longformedtoengageupper tab.FabricatedfromNo.16MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.or2-7/8in.high,formedtoengage base.FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes. Tite-LocPlusARFloatingClip:Twopieceassembly;baseapproximately21/2in.wide,1-7/8in.longformedtoengageupper tab.FabricatedfromNo.18MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.high,formedtoengagebase. FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes.
Fasteners(Screws)Screwsusedtoattachthepanelclipstoplywood(Item4)tobeNo.10by1in.longPancakeheadwoodscrewswithaNo.2Phillipsheador10x1in.,1/4in.HexHeadWoodgrip.Twoscrewsperclip.Screwsusedatendlap(highsystemonly)tobeoneofthefollowing:14x1-1/4in.HexWasherHead,self-drilling;14x1in.TypeAB,HexWasherHeadself-tapping;14x1-1/4in.HexWasherHead,self-drilling;14x1in.TypeABPhillipsStainlessSteel,self-tapping.Fivescrewsperpanelina1,3,4,4,3in.pattern.Screwsusedtoattachplywood(Item4)towoodtrussesorjoists(Item7)tobeNo.8by2in.Bugleheadscrews.Asanoptionalfastener,2-1/2in.long8dcommondeformedshanknailsmaybeused.Whenlightgaugestructuralsteeljoistsareused,screwstobeNo.12by1-5/8in.longwithaPhillipshead.Spacingofscrewstobe6in.O.C.atplywoodorOSBendsand12in.O.C.atinteriorjoists.
Substructure(PlywoodorOSB)Plywooddeckingororientedstrandboard(OSB)tobeanom5/8in.thick,exposuresheathingspanC-D,40/20plywood.(Allbuttjointstobesealedagainstleakagebyusingtapeand/orcaulking).Inlieuofplywood,1in.tongueandgroovedeckingmaybeused.
EndlapBack-UpPlate(Optional-High-Systemonly)/(NotShown)Usedatpanelendlaps,16MSGmincoatedsteel,widthofbackupplatetocorrespondtowidthofpanel.Two,1in.wideby3/4in.longtabsforslidingoverendofpanel.
MoistureBarrier(Optional)/(NotShown)Anysuitablemembranetoprotectplywood(Item4).
ThermalSpacer(Optional)Polystyrene:3/8in.,5/8in.or1in.nomthickness,3in.wideby15-7/8in.long.JoistsJoists,spacedat2ft,0in.O.C.max,maybeoneofthefollowing:
Nom2by6in.woodjoists,No.2orbetter. Nom2by4in.woodwhenusedontopchordofawoodtruss,No.2orbetter. LightgaugestructuralsteelframingwiththememberagainsttheplywoodorOSBtobeaminNo.22MSGcoatedsteel.
RefertoGeneralInformation,RoofDeckConstructionforitemsnotevaluated.
*BearingtheULClassificationMarking
1
2
3
4
4A
5
6
7
ABC
1'-4"
1
2
6
3
8
2.00"
2'-0"
4
1'-4"
1
2
6
3
8
2.00"
2'-0"
4
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935 4
UL Construction No. 616Uplift - Class 90 / Fire Not Investigated
UL
Co
nstr
uctio
n N
o.
61
6
MetalRoofDeckPanel*/“Tite-LocPlus”Minimum0.032in.thickAluminum,18in.max,12in.min.width,2in.highattheribs.Alineofsealantmaybeusedatpanelendsandsidelaps.Sidelaptobetightenedandcrimpedwithanelectricseamingmachinetoanangleof180degrees.Crimpingprocesstoincludetheupperportionofthepanelclip(Item2).
RoofDeckFasteners*(PanelClips)Anyofthefollowing.Clipspacingtobe30in.OCmax.Sealantmaybeusedatthetopoftheclips:
Tite-LocPlusUtilityClip:Onepieceassembly;3in.wide,approximately2in.highwithtwoguideholesinbase.Fabricated fromNo.22MSGcoatedsteel. Tite-LocPlusLowFixedClip:Onepieceassembly;3in.wide,approximately2-3/8in.or3in.high,withthreeguideholesin base.FabricatedfromNo.22MSGcoatedsteel. Tite-LocPlusLowFloatingClip:Twopieceassembly;baseapproximately2in.wide,1-11/16in.longformedtoengageupper tab.FabricatedfromNo.16MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.or2-7/8in.high,formedtoengage base.FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes. Tite-LocPlusARFloatingClip:Twopieceassembly;baseapproximately21/2in.wide,1-7/8in.longformedtoengageupper tab.FabricatedfromNo.18MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.high,formedtoengagebase. FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes.
Fasteners(Screws)Theplywooddeckissecuredtothesupportswith2-1/2in.drywallscrewsspaced6in.oncenterattheperimeterand12in.oncenterinthefield.TheTite-LocPlusClipisfastenedtothedeckwithtwo#10-12x1in.longPhillipsdrivescrews.Paneledgesareattachedtotheplywoodwith2-1/2in.longdrywallscrews,spaced6in.oncenterand1in.fromthepaneledge.
SupportsWoodNo.2orbetter,2in.x10in.x179in.,spaced24in.oncenter.
PlywoodDecking19/32in.B-CgradeAPARated.Alljointsaresealedwitha1in.wideurethaneCaulk(BostikChem)curedfor16hours.Theentiredeckiscoveredwithanasphalt-saturatedfeltperthemanufacturersinstallationinstructions.
OrientedStrandBoard(OSB)/(NotShown)Asanalternate,nom.5/8in.thick(19/32in.actual)APAratedOSBmaybesubstitutedforplywooddecking(Item5).Installationproceduresaretobesameasforplywood.
RefertoGeneralInformation,RoofDeckConstructionforitemsnotevaluated.
*BearingtheULClassificationMarking
1
2
3
4
5
5A
1'-6"
30" O.C. 30" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
1'-6"
30" O.C. 30" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
1'-6"
30" O.C. 30" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
1'-6"
30" O.C. 30" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
5
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
UL Construction No. 617 Uplift - Class 90 / Fire Not Investigated
UL
Co
nstr
uctio
n N
o.
61
7
MetalRoofDeckPanels*/“Tite-LocPlus”Minimum24MSGthicksteel,18in.max,12in.min.width,2in.highattheribs.Alineofsealantmaybeusedatpanelendsandsidelaps.Sidelaptobetightenedandcrimpedwithanelectricseamingmachinetoanangleof180degrees.Crimpingprocesstoincludetheupperportionofthepanelclip(Item2).
RoofDeckFasteners*(PanelClips)Anyofthefollowing.Clipspacingtobe48in.OCmax.Sealantmaybeusedatthetopoftheclips:
Tite-LocPlusUtilityClip:Onepieceassembly;3in.wide,approximately2in.highwithtwoguideholesinbase.Fabricated fromNo.22MSGcoatedsteel. Tite-LocPlusLowFixedClip:Onepieceassembly;3in.wide,approximately2-3/8in.or3in.high,withthreeguideholesin base.FabricatedfromNo.22MSGcoatedsteel. Tite-LocPlusLowFloatingClip:Twopieceassembly;baseapproximately2in.wide,1-11/16in.longformedtoengageupper tab.FabricatedfromNo.16MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.or2-7/8in.high,formedtoengage base.FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes. Tite-LocPlusARFloatingClip:Twopieceassembly;baseapproximately21/2in.wide,1-7/8in.longformedtoengageupper tab.FabricatedfromNo.18MSGcoatedsteel.Tabapproximately4-5/16in.wide;2-3/8in.high,formedtoengagebase. FabricatedfromNo.22MSGcoatedsteel.Basetohavetwoguideholes.
Fasteners(Screws)Theplywooddeckissecuredtothesupportswith2-1/2in.drywallscrewsspaced6in.oncenterattheperimeterand12in.oncenterinthefield.TheTite-LocPlusclipisfastenedtothedeckwithtwo#14-1/4x1in.longPhillipsdrivescrews.Paneledgesareattachedtotheplywoodwith2-1/2in.longdrywallPhillipheadscrews,spaced6in.oncenterand1in.fromthepaneledge.
SupportsWoodNo.2orbetter,2in.x10in.x179in.,spaced24in.oncenter.
PlywoodDecking19/32in.B-CgradeAPARated.Alljointsaresealedwitha1in.wideurethaneCaulk(BostikChem)curedfor16hours.Theentiredeckiscoveredwithanasphalt-saturatedfeltperthemanufacturersinstallationinstructions.
OrientedStrandBoard(OSB)/(NotShown)Asanalternate,nom.5/8in.thick(19/32in.actual)APAratedOSBmaybesubstitutedforplywooddecking(Item5).Installationproceduresaretobesameasforplywoodexceptthattheclipsshallbespacedamaximumof30in.
RefertoGeneralInformation,RoofDeckConstructionforitemsnotevaluated.
*BearingtheULClassificationMarking
1
2
3
4
5
5A
1'-6"
48" O.C. 48" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
1'-6"
48" O.C. 48" O.C.
1
25
3
4
5 1
2 3
2.00"
5/8"
6
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
UL
Co
nstr
uctio
n N
o.
26
3
UL Construction No. 263Metal Roof Deck Panels / File R14293
Type“Snap-Clad”roofdeckpanels(No.24MSGmingaugecoatedsteelor0.032min.gaugecoatedaluminum)placedoverspecifiedinsulationand/orroofcoveringforrespectivedesigns.Type“Snap-Clad”panelsaresecuredby“Snap-CladClips”withtheupperportionoftheclipengagingthepanelrib.A4-1/2by6in.bearingplatefabricatedfromNo.26MSGcoatedsteelisusedundereachpanelclip(thebearingplateshallbeplacedoverthespecifiedinsulation).PanelclipsareattachedtothesteeldeckwithNo.14steelscrewshavingaNo.3Phillips-drivetrussheadwithanoff-setdrill-typepoint.Twofastenersperclipareused.
P225,P227,P230,P233,P237,P259,P508,P510,P512,P514,P701,P711,P717,P720,P722,P723,P724,P726,P731,P734,P736,P801,P815,P819andP821.
Types“HighSnap-OnStandingSeam”,“Snap-OnStandingSeam”,“IntegralBatten”,“IntegralStandingSeam”,“Redi-RoofStandingSeam”,“Redi-RoofBatten”,“Snap-Clad”,“Tite-Loc”,“Tite-LocPlus”roofdeckpanels(No.24MSGmin.gaugecoatedsteelor0.032min.gaugecoatedaluminum)placedoverspecifiedinsula-tionand/orroofcoveringforrespectivedesigns.Panelssecuredtoatoplayerof7/16in.APA-Ratedorientedstandboard(OSB)laminatedtorigidinsulationor5/8in.plywoodoverrigidinsulation.Panelssecuredtoorientedstrandboardorply-woodatsideribswithpanelclipsdesignedspecificallyforthesepanels.Panelclipsspaced18in.OCusingNo.10by1-1/4in.longself-drilling,selftappingwaferhead.Zinc-platedcarbonsteelscrews.Theorientedstrandboardlaminatedinsulationorplywoodcoveredrigidinsulationaremechanicallyfastenedtosteelroofdeckandcoveredwitha30lb.felt.
P225,P227,P230,P233,P237,P259P508,P510,P512,P514,P515,P701,P711,P717,P720,P722,P723,P724,P726,P731,P734,P736,P801,P815,P819andP821.
Types“Tite-Loc”and“Tite-LocPlus”roofdeckpanels(No.24MSGmin.gaugecoatedsteelor0.032min.gaugecoatedaluminum)placedoverspecifiedinsulationand/orroofcoveringforrespectivedesigns.Bothtypessecuredtohatsections+orbearingplates++withpanelclipsdesignedfortheparticularpanel.
P225,P227,P230,P233,P237,P508,P510,P512,P701,P711,P715,P717,P720,P722,P724,P726,P731,P734,P736,P801,P803,P814,P815,P819,P821
andP823.
+Hat-shapedmembertobeaminimumof16MSG,1in.min.depth.MembertobefastenedthroughtheroofinsulationtothesteelroofdeckwithNo.14self-drillingand/orself-tappingfasteners.Spacingtobedeterminedbythestructuralloadingrequirements.Inaddition,anycompressibleULClassifiedglassfibercompressibleblanketinsulationwithorwithoutavaporretardingfacingmaybeusedbetweenthespecifiedroofinsulationandthemetalroofpanels.
++Bearingplatetobeaminimumof16MSG.MembertobefastenedthroughtheroofinsulationtothesteeldeckwithNo.14self-drillingand/orself-tappingfasteners.
MechanicallyAttachedMetalRoofPanels
ForuseinDesignNumbers:
MechanicallyAttachedMetalRoofPanels
ForuseinDesignNumbers:
MechanicallyAttachedMetalRoofPanels
ForuseinDesignNumbers:
1
2
3
MechanicallyAttachedMetalRoofPanels
7
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
UL
Co
nstr
uctio
n N
o.
79
0
CoatedSteelandaluminumpanelidentifiedas“Snap-OnStandingSeam”,“HighSnap-OnStandingSeam”,“Snap-OnBatten”,“IntegralBatten”,“Redi-RoofBatten”,“Redi-RoofStandingSeam”,“Snap-Clad”,“IntegralStandingSeam”,“Tite-Loc”and“Tite-LocPlus”.
UL Construction No. 790Class A
NCNoLimitations1/4in.minG-PGypsumDensDeck®AnyULClassifiedTypeG1,G2orG3base/plysheet,Type15,20or30feltorULClassifiedpreparedroofingaccessoryorWRGrace“IceandWaterShield”Steeloraluminumroofingpanels,mechanicallyfastened
NCNoLimitations5/8inmin.plywoodAnyULClassifiedTypeG1,G2orG3base/plysheet,Type15,20or30feltorULClassifiedpreparedroofingaccessoryorWRGrace“IceandWaterShield”Steelroofingpanels,mechanicallyfastened
NCNoLimitations7/16OBSor5/8in.plywoodoverpolyisocyanurateinsulationboardorpolyisocyanuratecompositeboard,anythicknessAnyULClassifiedTypeG1,G2orG3base/plysheet,Type15,20or30feltorULClassifiedpreparedroofingaccessoryorWRGrace“IceandWaterShield”Steeloraluminumroofingpanels,mechanicallyfastened
NCNoLimitationsPolyisocyanurate,glassfiber,perliteorwoodfiber,anythicknessAnyULClassifiedTypeG1,G2orG3base/plysheet,Type15,20or30feltorULClassifiedpreparedroofingaccessoryorWRGrace“IceandWaterShield”Steeloraluminumroofingpanels,mechanicallyfastened
NCNoLimitationsSteelroofingpanels,mechanicallyattachedtometalpurlins
C-15/32NoLimitations1/4in.minG-PGypsumDensDeck®withalljointsstaggeredaminof6in.fromtheplywoodjointsAnyULClassifiedTypeG1,G2orG3base/plysheet,Type15,20or30feltorULClassifiedpreparedroofingaccessoryorWRGrace“IceandWaterShield”Steeloraluminumroofingpanelsmechanicallyfastened
Deck:Incline:BarrierBoard:PlySheet(optional):
Surfacing:
Deck:Incline:BarrierBoard:PlySheet(optional):
Surfacing:
Deck:Incline:BarrierBoard:
PlySheet(optional):
Surfacing:
Deck:Incline:Insulation:PlySheet(optional):
Surfacing:
Deck:Incline:Surfacing:
Deck:Incline:BarrierBoard:
PlySheet(optional):
Surfacing:
1
2
3
4
5
6
8
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
UL
Co
nstr
uctio
n C
od
e &
Flo
rid
a A
pp
rova
ls
UL Construction CodeMaximum Clip Spacing
Substrates
Width
16”,12”
16”,12”
16”,12”
18”,16”,12”
16”,12”
16”,12”
16”,12”
18”,16”,12”
18”,16”,12”
18”,16”,12”
OpenFramePurlins
UL90(5’-0”)
UL176(5’-0”)
UL449(5’-0”)
UL90(5’-0”)
UL176(5’-0”)
UL449(5’-0”)
SolidSubstrate
UL437(5’-0”)
UL451(2’-0”)
UL452(2’-0”)
UL617(4’-0”)
UL437(5’-0”)
UL451(2’-0”)
UL452(2’-0”)
UL617(4’-0”)
UL616(2’-6”)
UL616(2’-6”)
RigidInsulationOver
22GASteelDeck
WithBearingPlates
UL180(5’-0”)
UL238B(2’-6”)
UL487(4’-0”)
UL180(5’-0”)
UL238B(2’-6”)
UL487(4’-0”)
Gauge
22GA
24GA
0.032
0.040
ContactPetersenAluminumCorporationforcompleteULconstructionassemblies.
Forcompleteinformationregardingappropriatepurlinspacing,contactPetersenAluminumCorporationdirectly.
Insulationthicknessesvariesbetween1”and4-1/2”accordingtoR-valuedesired.RefertoULRoofingMaterialsdirectly.
ClipspacingshouldbeevaluatedfortheapplicableBuildingCodeorgoverningregulation.ContactPetersenAluminumCorp.fortechnicalassisstanceregardingprojectspecificspacing.
1
2
3
4
Florida Product ApprovalsTi te-LocPlusMiami-DadeNOA’S&F lor idaApprovals
Width
16”,12”
16”,12”
16”,12”
16”,12”
Miami-DadeNOA#
07-0924.10
07-0924.10
07-0924.09
FloridaApproval#
#5562
#5562
#5562
#10879
Gauge
22GA
24GA
.032Alum.
.040Alum.
9
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
Valley Detail
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
9
"Z" RETAINER STRIPSET IN SEALANT
CLIP W/FASTENERSTITE-LOC PLUS "AR"
TITE-LOC PLUS PANEL
PA-115VALLEY FLASHING
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
ICE & WATER SHIELD
SEE FOOT NOTE
* GAP APPROPRIATE FOR EXPANSION/CONTRACTION (CONSULT FACTORY)
Tite-L
oc P
lus F
lash
ing
Deta
ils
NOTE: MiNiMuM 6” frOM ENd Of paNEl TO VallEy diVErTEr ON Each sidE Of paNEl. cONsulT pac ON lONgEr VallEy ruNs.
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935 10
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
TITE-LOC PLUS PANEL
PA-101 HIP/RIDGE FLASHINGW/ "Z" CLOSURES
SEALANT
& UNDER "Z")(AT VERTICAL LEG
3/4" TURN-UP SEALANT
TYPE "AB"10-12 x 1"
5/8" PLYWOOD
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
Hip/Ridge Detail
11
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
11
Tite-L
oc P
lus F
lash
ing
Deta
ils
TITE-LOC PLUS PANEL
CLIP W/FASTENERSTITE-LOC PLUS "AR"
SEALANT
& UNDER "Z")(AT VERTICAL LEG
3/4" TURN-UP
SEALANT
PA-101 HIP/RIDGE FLASHING
PERFORATED "Z"W/ "Z" CLOSURES
POP-RIVET
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
ICE & WATER SHIELD
Vented Ridge Detail
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
Eave Detail
12
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
PA-116 EAVE FLASHING
"Z" RETAINER STRIPSET IN SEALANT
PA-5 KEEPER
CLIP W/FASTENERSTITE-LOC PLUS "AR"
TITE-LOC PLUS PANEL
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
ICE & WATER SHIELD
SEE FOOT NOTE
* GAP APPROPRIATE FOR EXPANSION/CONTRACTION (CONSULT FACTORY)T
ite-L
oc P
lus F
lash
ing
Deta
ils
13
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils IN PANEL. FIELD CUT & BEND RETURN
CLIP W/FASTENERSTITE-LOC PLUS "AR"
TITE-LOC PLUS PANEL
PA-126 EAVE FLASHING
PA-5 KEEPER
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
ICE & WATER SHIELD
SEE FOOT NOTE
* GAP APPROPRIATE FOR EXPANSION/CONTRACTION (CONSULT FACTORY)
Eave Detail
14
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
EAVE FLASHING
SEALANT (AT VERTICAL
TITE-LOC PLUS PANEL
LEG & UNDER "Z")
CLIP W/FASTENERSTITE-LOC PLUS "AR"
TITE-LOC PLUS PANEL
"Z" RETAINER STRIPSET IN SEALANT
TYPE "AB"10-12 x 1"
5/8" PLYWOOD
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
SEE FOOT NOTE
* GAP APPROPRIATE FOR EXPANSION/CONTRACTION (CONSULT FACTORY)
Eave Detail
15
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
PA-5 KEEPER
PA-151 GABLE FLASHINGW/ "J" CLOSURE
SEALANT
FIELD-FORM PANEL LEG TOI.D. OF "J" CLOSURE
TITE-LOC PLUS PANEL
TYPE "AB" 10-12 x 1"
5/8" PLYWOOD
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
Gable Detail
16
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
W/ "Z" CLOSUREPA-111 PITCH BREAK DETAIL
TITE-LOC PLUS PANEL
3/4" TURN-UP
TITE-LOC PLUS PANEL
SEALANT
& UNDER "Z")(AT VERTICAL LEG 5/8" PLYWOOD
TYPE "AB"10-12 x 1"
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
CLIP W/FASTENERSTITE-LOC PLUS "AR"
Pitch Break Detail
17
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
SEALANT
PA-801 OUTSIDE CORNER FLASHINGW/ "Z" CLOSURES
FIELD-FORMED PANEL
TITE-LOC PLUS PANEL
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
POP RIVET
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
Outside Corner Detail
18
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
TITE-LOC PLUS PANEL
W/ "J" CLOSURESPA-701 INSIDE CORNER FLASHING
SEALANT
FIELD-FORM PANEL LEG TOI.D. OF "J" CLOSURE
POP RIVET
5/8" PLYWOODTYPE "AB"10-12 x 1"
SEALANT
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
Inside Corner Detail
19
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
PA-143 PEAK FLASHINGW/ "Z" CLOSURE
SEALANT
& UNDER "Z")(AT VERTICAL SEAM
PA-5 KEEPER
3/4" TURN-UP TITE-LOC PLUS PANEL
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
Peak Detail
20
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
W/ REGLET & "Z" CLOSUREPA-121 COUNTER FLASHING
FASTENER
TITE-LOC PLUS PANEL
3/4" TURN-UP
SEALANT (AT VERTICALLEG & UNDER "Z")
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Head Wall Detail
Tite-L
oc P
lus F
lash
ing
Deta
ils
21
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
"J" CLOSURE FOR SOFFIT
SOFFIT PANELPA-305 FASCIA TO SOFFITFLASHING
TITE-LOC PLUS PANEL
CLIP W/FASTENERSTITE-LOC PLUS "AR"
TYPE "AB"10-12 x 1"
5/8" PLYWOOD
ICE & WATER SHIELD
Fascia to Soffit
22
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
SOFFIT FLASHINGPA-405 FASCIA TO
FRAMING MEMBERS
TITE-LOC PLUS PANEL
CLIP W/FASTENERSTITE-LOC PLUS "AR"
"J" CLOSURE FOR SOFFIT
SOFFIT PANEL
TYPE "AB"10-12 x 1"
5/8" PLYWOOD
ICE & WATER SHIELD
Fascia to Soffit
23
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils
FLASHING W/"Z" CLOSUREPA-222 GRAVEL STOP/HEAD
SEALANT
TITE-LOC PLUS PANEL
CLIP W/FASTENERSTITE-LOC PLUS "AR"
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
ICE & WATER SHIELD
Gravel Stop/Head Detail
24
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ilsTITE-LOC PLUS PANEL
SPECIFIED BY ARCHITECTGUTTER SUPPORT AS
(FIELD-FORMED)GUTTER STRAP
GUTTER FLASHING
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
SEE FOOT NOTE
* GAP APPROPRIATE FOR EXPANSION/CONTRACTION (CONSULT FACTORY)
Gutter Detail
25
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Tite-L
oc P
lus F
lash
ing
Deta
ils TITE-LOC PLUS FASCIA PANEL
CLIP W/FASTENERSTITE-LOC PLUS "AR"
W/ "J" CLOSUREPA-601 FASCIA/RAKE WALL FLASHING
SEALANT
FIELD-FORM PANEL LEG TOI.D. OF "J" CLOSURE
TITE-LOC PLUS PANEL
TYPE "AB"10-12 x 1"
5/8" PLYWOOD
ICE & WATER SHIELD
Fascia/Rake Wall Detail
26
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935
PA-205 SILL FLASHING
TITE-LOC PLUS PANEL
5/8" PLYWOOD
TYPE "AB"10-12 x 1"
CLIP W/FASTENERSTITE-LOC PLUS "AR"
ICE & WATER SHIELD
J o b N ame :
D a t e :
C o n t r a c t o r : N o t e s :
Sill Detail
Tite-L
oc P
lus F
lash
ing
Deta
ils
27
PRODUCT NAMEPAC-CLAD®-PrefinishedSheetAluminum&Steel
MANUFACTURERPetersenAluminumCorporation1005TonneRoadElkGroveVillage,IL60007P:800-323-1960847-228-7150F:800-722-7150www.pac-clad.com
PRODUCT DESCRIPTIONPAC-CLADisapre-finishedspecificationgradealuminumsheetoracommercialqualityextra-smoothgalvanizedsteelsheet,primedandcoatedwithPetersen’sfullstrengthfluoropolymer(PVDF)high-performancecoatingsystemof1.0mil(0.025mm)totaldryfilmthicknessand,onthereverseside,awashcoatof0.3–0.4mil(0.008–0.01mm)dryfilmthickness.
BasicUse:PAC-CLADisforgeneralsheetmetaluseinbuildingapplications.PAC-CLADisfrequentlyusedinthefollowingforms:•Fasciaandsoffitpanels•Gravelstopsandcopings•Storefrontcomponents•Roofingandmansardpanels:flat,battenandstandingseamtypes
MaterialsandFinishes:PAC-CLADconsistsofeitherAluminumAssociationspecificationASTMB209aluminumsheet,temperH14orH34,orhot-dippedASTMA653GradeAstructuralqualitysteelsheets,AISIG90galvanized,commercialweight.PAC-CLADsheetsarecoatedwitha2-coatsystemusing
acombinationof70%Kynar500®polyvinylidenefluoride(PVDF),acrylicresins,pigmentsandsolvents.ThesystemconsistsofFluropon®topcoatappliedoverapolyesterprimer.Awashcoatisappliedtothereversesideforadditionalprotection.
StandardSizes:Aluminumisavailablein.032”-.080”(0.8–2mm)thicknessin48”(1219mm)widths.Galvanizedsteelisavailablein24gain48”(1219mm)widths.
SpecialSizes:Aluminumisavailableinthicknessto.125”(3.2mm)andinwidthsto60”(1524mm)onspecialorder.Minimumquantityis20,000lb(9080kg).Galvanizedsteelisavailableingaugesfrom26–18andinwidthsupto60”(1525mm)onspecialorder.Minimumquantityis20,000lb(9080kg).
Colors:Forstandardcolors,refertoTable1.Custommatchcolorsareavailableinminimumquantitiesof10,000lb(4540kg).
Finish:Sheensavailable–Dull,matteandspecular,glossratingof25–35%at60°viewingangle.Texturesavailable:Smooth;stuccoembossedtextureE-5.
Limitations:PAC-CLADperformancedependsontheintegrityofthecoatingfilm,andingalvanizedsteel,ontheunderlyingcoatingofzinc.PAC-CLADshouldnotbeusedinareasofhighabrasionorwhereitwillbesubjecttomechanicaldamage.
TECHNICAL DATAApplicableStandards:AluminumAssociation–Specificationsfor
AluminumStructuresAmericanIronandSteelInstitute(AISI)•AISIG90-HotDippedGalvanizedSteelSheet,CommercialWeight•SpecificationsforCold-FormedSteelDesignManual
AmericanSocietyforTesting&Materials(ASTM)•ASTMA525–SteelSheet,Zinc-CoatedbytheHotDipProcess•ASTMA653/A653-97–SteelSheet,Zinc-Coated(Galvanized)bytheHotDipProcess,StructuralPhysicalQuality•ASTMB117-95–OperatingSaltSpray(Fog)Apparatus•ASTMB209/B209M-97–AluminumandAluminumAlloySheetandPlate•ASTMD523-89(1994)el–SpectralGloss•ASTMD659–DiscontinuedstandardreplacedbyASTMD4214•ASTMD968-93–AbrasionResistanceofOrganicCoatingsbyFallingAbrasive•ASTMD1737-97–Discontinuedstandard,replacedbyASTMD522•ASTMD1808-Discontinuedstandard•ASTM2247-94–TestingWaterResistanceofCoatingsin100%RelativeHumidity•ASTM2794-93–ResistanceofOrganicCoatingstotheEffectsofRapidDeformation(Impact)•ASTM3281–Discontinuedstandard•ASTM3359-95a–MeasuringAdhesionbyTapeTest•ASTMD3363-82e1–FilmHardnessbyPencilTest•ASTMG23-96–OperatingLight-ExposureApparatus(CarbonArcType)WithandWithoutWater
SP
EC
- DA
TA
®
SPEC DATA®
Sheet Metal Roofing 07610
Petersen Aluminum Corporation
1
2
3
4
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
28
SP
EC
- DA
TA
®
FactoryMutual(FM)–LossPreventionDataSheets1-7and1-49
NationalCoilCoatersAssociation(NCAA)•NCAAProcedureNo.11-5•NCCAProcedureNo.11-18•NCCATechnicalBulletinNo.11-6
SheetMetal&AirConditioningContractorsNationalAssociation,Inc.(SMACNA)-ArchitecturalSheetMetalManual
PhysicalPropertiesofFluoropolymerCoating:•AbrasionResistance–ASTMD968,coefficientofsandabrasion65±10•AcceleratedWeathering,Chalk-ASTMG23,TypeEH,5000hours,ratingof8orbetter•AcceleratedWeathering,Color-ASTMG23.TypeEH,5000hours,≤5∆E(HunterUnits)colorchange•Adhesion–ASTMD3359/NCCAProcedureNo.11-5cross-cuttapetest,pass•ChalkResistance–ASTMD659,nochalkrating9–10•ColorChange–20years,≤5∆E (HunterUnits)change,afterremovalofexternaldeposits•Chemical/AcidPollutionResistance–ASTMD1808;pass,nocolorchange•Formability–ASTMD3281andASTMD1737,canbeformedwithoutfilmfractureusingnormalshoppracticestoa1to2-Tbendradius•Gloss–ASTMD523Specularglossof30°+5(lowgloss/sheenavailable)at60;26gaPAC-CLADGLOSS10+5AT60°•Hardness–ASTMD3363-≥Fpencilhardness•HumidityResistance–ASTMD2247,1000hours,nochangeinhardness•ImpactResistance–ASTMD2794andNCCATechnicalBulletinNo.11-6,70lb-inch(7.9Nom.),notapepick-off
•LifeExpectancy–ASTMG23.TypeEM,weatherometer,5000hours,chalkratingof8orbetter•SaltSprayResistance,Aluminum–ASTMB117,2000hours,creepageatscribe≤1/32”(0.8mm),noblisters•SaltSprayResistance,Steel–ASTMB117,1000hours,creepageatscribe≤1/8”(3.2mm),few#8blisters•SolventResistance–NCCAprocedure11-18,(nocomparableASTMtest),pass
INSTALLATIONMethods:FabricateandinstallPAC-CLADsheetmetalinaccordancewithSMACNAsheetmetalpractices.PAC-CLADcanbecut,formed,nailed,screwedorrivetedusingconventionalhandorpowertools.PAC-CLADcoatingsmustbemechanicallyremovedifsolderingorweldingarenecessary.Forbestresults,cuttingedgesshouldbekeptsharp,clean,properlydressedandcloselyaligned.
Astrippablevinylfilmcanbeappliedforprotectionduringfabricationandinstallationisdesired.Vinylfilmmayremainonthecoatingduringfabricationanderection.Vinylmustberemovedpriortoorimmediatelyafterinstallation.
PAC-CLADisafinishedmaterial;caremustbetakenduringfabricationanderectiontoavoiddamagetothesurface.Properbendradiimustbeusedinfabrication.
AVAILABILITY & COSTAvailability:PAC-CLADpanelsareavailablenation-wideandarestockedinstandardcolorsforrapidshippingwithin72hours.Specialfinishesrequireadditionaltimeforcolormatchingandapprovals.
Thereisa20,000lb(9080kg)minimumfornon-standardwidthsand
colors.Deliverytimeandpricewillbequoteduponinquiry.
Cost:CostforPLAC-CLADpanelsisgenerally60%ofcopperroofingsheet,25%to50%lessthanhardcoatanodizedfinishesandapproximatelyequaltoshoporfieldpaintedgalvanizedsteel.Contactthemanufacturerforspecificcosts.
WARRANTYA20-yeaar,non-proratedwarrantycoveringcolor,fade,chalkingandfilmintegrityisavailableatnoadditionalcost.Thewarrantyisissuedonaperprojectbasisuponrequest.
MAINTENANCEMaintenanceisnotrequired.ThepanelfinishisamemberoftheTeflon®familyandisself-cleaning.Ifcleaningisdesired,panelscanbewashedwithmildsoapandwaterfollowedbyacleanwaterrinse.
TECHNICAL SERVICESTechnicalservicesareavailablefromPetersenAluminumCorporationandregionalarchitecturalrepresentatives.
FILING SYSTEMS•Architects’FirstSourceforProducts•MANU-SPEC®•Sweet’sCatalogFiles
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
5
6
7
8
9
10
29
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
PAC-CLADStandard Reflectivity Emissivity 3YearExposure
SRI* Steel24ga.22ga.
Aluminum.032.040.050.063
Almond 0.56 0.89 0.57 66 √ √ √ √ √
ArcadiaGreen 0.33 0.84 0.33 33 √ √
BoneWhite 0.73 0.89 0.71 89 √ √ √ √ √ √
CardinalRed 0.37 0.89 0.38 41 √ √ √
Charcoal 0.28 0.89 29 √ √ √
Cityscape 0.37 0.85 0.34 39 √ √ √ √
ColonialRed 0.32 0.89 34 √ √ √ √
DarkBronze 0.25 0.89 25 √ √ √ √ √ √
Evergreen 0.26 0.88 26 √ √
Granite* 0.36 0.89 0.35 40 √ √ √ √ √
HemlockGreen 0.30 0.90 32 √ √ √ √
HunterGreen 0.26 0.88 26 √ √
MansardBrown 0.25 0.88 25 √ √ √ √ √
MatteBlack** 0.25 0.85 23 √ √ √ √ √
MediumBronze 0.27 0.90 28 √ √ √ √ √ √
MilitaryBlue 0.34 0.88 36 √ √
MusketGray 0.31 0.89 33 √ √ √ √
PatinaGreen 0.34 0.89 37 √ √
Sandstone 0.53 0.89 0.49 62 √ √ √ √ √ √
SierraTan 0.36 0.89 0.35 40 √ √ √ √ √
SlateBlue 0.26 0.87 26 √ √
SlateGray 0.36 0.89 40 √ √ √ √ √
StoneWhite 0.64 0.88 0.59 77 √ √ √ √ √ √
Teal 0.26 0.88 26 √ √
TerraCotta 0.36 0.89 0.37 40 √ √ √
PAC-CLADMetallic
AgedCopper 0.28 0.89 29 √ √ √
Champagne 0.41 0.80 0.40 43 √ √ √
CopperPenny 0.49 0.87 0.47 56 √ √ √ √
Silver 0.60 0.83 0.55 70 √ √ √ √
WeatheredZinc 0.30 0.81 28 √ √ √
Zinc 0.32 0.89 0.31 34 √ √ √
PAC-CLADStandardColors(donotmeetcoolroofrequirements)
AwardBlue √ √ √
BerkshireBlue* √
Burgundy √ √ √
ForestGreen √ √ √ √ √
HartfordGreen √ √ √ √
InterstateBlue √ √ √
SP
EC
- DA
TA
®
PAC-CLAD Color Availability
*LowGlossColors**MatteBlack(SRIColor)insteelonly
30
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
ThisMANU-SPEC®utilizestheConstructionSpecificationsInstitute(CSI)ProjectResourceManual(PRM),includingMasterFormat™,SectionFormat™andPageFormat™.AMANU-SPECisamanufacturer-specificproprietaryproductspecificationusingtheproprietarymethodofspecifyingapplicabletoprojectspecificationsandmasterguidespecifications.Optionaltextisindicatedbybrackets[];deleteoptionaltextinfinalcopyofspecification.SpecifierNotesprecedespecificationtext;deletenotesinfinalcopyofspecification.Trade/brandnameswithappropriatesymbolstypicallyareusedinSpecifierNotes;symbolsarenotusedinspecificationtext.Metricconversion,whereused,issoftmetricconversion.
ThisMANU-SPECspecifiesfactory-formedmetalwall,soffitandroofpanels.TheseproductsaremanufacturedbyPetersenAluminumCorp.ReviseMANU-SPECsectionnumberandtitlebelowtosuitprojectrequirements,specificationpracticesandsectioncontent.RefertoCSIMasterFormatforothersectionnumbersandtitles.
MANU-SPEC™
07410
SECTION 07410: Metal Roof & Wall Panels
PART 1 GENERAL
SUMMARY A.SectionIncludes:ThisSectionspecifiesfactory-formedmetalwall,soffitandroofpanels. B.RelatedSections:
SpecifierNote:IncludeinthisArticleonlythosesectionsthatdirectlyaffecttheworkofthissection.DonotincludeDivision00orDivision01sectionssinceitisassumedthatalltechnicalsectionsarerelatedtoallprojectDivision00andDivision01sectionstosomedegree.
1.Section[______].
SpecifierNote:Articlebelowmaybeomittedwhenspecifyingmanufacturer’sproprietaryproductsandrecommendedinstallation.RetainReferenceArticlewhenspecifyingproductsandinstallationbyanindustryreferencestandard.Ifretained,liststandard(s)referencedinthissection.Indicateissuingauthorityname,acronym,standarddesignationandtitle.Establishpolicyforindicatingeditiondateofstandardreferenced.ConditionsoftheContractorSection014219-ReferenceStandardsmayestablishtheeditiondateofstandards.Thisarticledoesnotrequirecompliancewithstandard,butismerelyalistingofreferencesused.Articlebelowshouldlistonlythoseindustrystandardsreferencedinthissection.RetainonlythosereferencestandardstobeusedwithinthetextofthisSection.Addanddeleteasrequiredforspecificproject.
REFERENCES A.ASTMInternational: 1.ASTMA653/A653StandardSpecificationforSteelSheet,Zinc-Coated(Galvanized)orZinc-IronAlloy- Coated(Galvannealed)bytheHot-DipProcess. 2.ASTMA792/A792MStandardSpecificationforSteelSheet,55%Aluminum-ZincAlloy-CoatedbytheHot DipProcess. 3.ASTMB209StandardSpecificationforAluminumandAluminum-AlloySheetandPlate. 4.ASTME283StandardTestMethodforDeterminingRateofAirLeakageThroughExteriorWindows, CurtainWalls,andDoorsUnderSpecifiedPressureDifferencesAcrosstheSpecimen.
1.01
1.02M
AN
U-S
PE
C®
31
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
MA
NU
-SP
EC
®
5.ASTME331StandardTestMethodforWaterPenetrationofExteriorWindows,Skylights,Doors,andCurtain WallsbyUniformStaticAirPressureDifference. 6.ASTME1592StandardTestMethodforStructuralPerformanceofSheetMetalRoofandSidingSystemsby UniformStaticAirPressureDifference. 7.ASTME1646StandardTestMethodforWaterPenetrationofExteriorMetalRoofPanelSystemsbyUniform StaticAirPressureDifference. 8.ASTME1680StandardTestMethodforRateofAirLeakageThroughExteriorMetalRoofPanelSystems.
B.FMGlobal(FactoryMutual): 1.FMClassI-90.
C.SheetMetalandAirConditioningContractor’sNationalAssociation(SMACNA): 1.SMACNAArchitecturalSheetMetalManual.
D.UnderwritersLaboratories,Inc.(UL): 1.UL263FireTestsofBuildingConstructionandMaterials. 2.UL580TestsforUpliftResistanceofRoofAssemblies. 3.UL790StandardTestMethodsforFireTestsofRoofCoverings. 4.UL2218ImpactResistanceofPreparedRoofCoveringMaterials.
SYSTEMDESCRIPTION A.Materials: 1.G90hot-dippedgalvanizedGradeAstructuralqualitysteelincompliancewithASTMA653. 2.Alloy3105[H14][H34]aluminumpanelsincompliancewithASTMB209. 3.Cold-rolledcopper.
B.PerformanceRequirements: 1.WindupliftincompliancewithULClassification580forULClassified90ratedassemblies. 2.Staticairinfiltrationof0.06cfm/sf(0.028liters/second)with6.24psi(43kPa)airpressuredifferentialas testedinaccordancewithASTME283. 3.Nowaterinfiltrationatinwardstaticairpressuredifferentialofnotlessthan6.24psi(43kPa)andnotmore than12psi(83kPa)astestedinaccordancewithASTME331.
SpecifierNote:ArticlebelowincludesthesubmittalofrelevantdatatobefurnishedbyContractorbefore,duringorafterconstruction.CoordinatethisarticlewithArchitect’sandContractor’sdutiesandresponsibilitiesinConditionsoftheContractandSection013300-SubmittalProcedures.
ACTIONSUBMITTALS A.General:SubmitlistedactionsubmittalsinaccordancewithConditionsoftheContractandSection[013300- SubmittalProcedures][______].
B.ShopDrawings:Indicateinformationonshopdrawingsasfollows: 1.Layout,profilesandproductcomponentsincludingdimensions,anchorage,erectiondetails,flashingdetails, elevations,plansandsectionsrequiredtoindicateconditions.
C.Samples:Submitasfollows: 1.[Duplicate][______],[12inch×12inch(305×305mm)][______]samplesofeach[Roofing][Soffit] [Wallpanel][______][And][Flashing]producttoshowselected[Colors][Finishes][Textures]usedonproject.
D.ProductData:Submitproductdata,includingmanufacturer’sSPEC-DATA®productsheet,for specifiedproducts. 1.MaterialSafetyDataSheets(MSDS).
1.03
1.04
32
MA
NU
-SP
EC
®
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
INFORMATIONSUBMITTALS A.QualityAssurance: 1.TestReports:Certifiedtestreportsshowingcompliancewithspecifiedperformancecharacteristicsand physicalproperties. 2.Certificates:Productcertificatessignedbymanufacturercertifyingmaterialscomplywithspecified performancecharacteristicsandcriteriaandphysicalrequirements. 3.Manufacturer’sInstructions:Manufacturer’sinstallationinstructions.
SpecifierNote:CoordinateparagraphbelowwithPart3FieldQualityRequirementsArticle.Retainordeleteasapplicable.
B.Manufacturer’sFieldReports:Manufacturer’sfieldreportsspecified.
CLOSEOUTSUBMITTALS A.Warranty:Submitwarrantydocumentsspecified.
B.OperationandMaintenanceData:Submitoperationandmaintenancedataforinstalledproductsin accordancewithSection[017800-CloseoutSubmittals][______]. 1.Include: a.Manufacturer’sinstructionscoveringmaintenancerequirements.
QUALITYASSURANCE A.Qualifications: 1.Installerexperiencedinperformingworkofthissectionwhohasspecializedininstallationofworksimilar tothatrequiredforthisproject. 2.ManufacturerQualifications:Manufacturercapableofprovidingfieldservicerepresentationduring constructionandapprovingerectionmethod.
SpecifierNote:Paragraphbelowshouldlistobligationsforcompliancewithspecificcoderequirementsparticulartothissection.GeneralstatementstocomplywithaparticularcodearetypicallyaddressedinConditionsoftheContractandSection014100-RegulatoryRequirements.Repetitivestatementsshouldbeavoided.Currentdataonbuildingcoderequirementsandproductcompliancemaybeobtainedfrommanufacturertechnicalsupportspecialists.
B.RegulatoryRequirements: 1.FMClassI-90. 2.SMACNAArchitecturalSheetMetalManual. 3.UL263. 4.UL580. 5.UL790. 6.UL2218.
C.PreinstallationMeetings:Conductpreinstallationmeetingtoverifyprojectrequirements,manufacturer’s installationinstructionsandmanufacturer’swarrantyrequirements.Complywith[Section013119-Project Meetings][______].
DELIVERY,STORAGE&HANDLING A.General:Complywith[016100-CommonProductRequirements][______].
B.Ordering:Complywithmanufacturer’sorderinginstructionsandleadtimerequirementstoavoid constructiondelays.
C.Delivery: 1.Delivermaterialsinmanufacturer’soriginalpackagingwithidentificationlabelsintact.
1.05
1.06
1.07
1.08
33
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
D.StorageandProtection: 1.Storematerialsprotectedfromexposuretoharmfulweatherconditionsandattemperatureconditions recommendedbymanufacturer. 2.Stackprefinishedmaterialtopreventtwisting,bending,abrasion,scratchinganddenting. 3.Elevateoneendofeachskidtoallowformoisturerunoff. 4.Preventcontactwithmaterialthatmaycausecorrosion,discolorationorstaining. 5.Providefactoryinstalledstrippablevinylfilmprotectivecoatingtopanels.
E.WasteManagementandDisposal:
SpecifierNote:Environment:Thedisposalofpackagingwasteintolandfillsitedemonstratesaninefficientuseofnaturalresourcesandconsumesvaluablelandfillspace.SpecifyingappropriatepackagingandconstructionwastemanagementanddisposalproceduresmaycontributetopointsrequiredforLEED®constructionprojectcertification.
1.Separatewastematerialsfor[Reuse][And][Recycling][_____]inaccordancewith[Section017419- ConstructionWasteManagementandDisposal][_____].
SpecifierNote:Manufacturermaytakebackpackaginganddeliverymaterialsforrecycling.
2.Removefromsiteanddisposeofpackagingmaterialsatappropriaterecyclingfacilities.Collectand separatefordisposal[Paper][Plastic][Polystyrene][Corrugatedcardboard][_____]packagingmaterial[In appropriateonsitebins][_____]forrecycling.
SpecifierNote:CoordinatearticlebelowwithConditionsoftheContractandwith[017836-Warranties][______].
PROJECTAMBIENTCONDITIONS A.InstallationLocation:Assembleanderectcomponentsonlywhentemperaturesareabove40degreesF (4degreesC).
SEQUENCING A.SequenceWithOtherWork:Complywithmanufacturer’swrittenrecommendationsforsequencing constructionoperations.
WARRANTY A.ProjectWarranty:RefertoConditionsoftheContractforprojectwarrantyprovisions.
B.Manufacturer’sWarranty:Submit,forOwner’sacceptance,manufacturer’sstandardwarrantydocument executedbyauthorizedcompanyofficial.Manufacturer’swarrantyisinadditionto,andnotalimitationof, otherrightsOwnermayhaveunderContractDocuments.
SpecifierNote:Coordinatearticlebelowwithmanufacturer’swarrantyrequirements.
C.Warranty:Commencingondateofacceptanceby[Owner][Architect][Consultant][_____].
MAINTENANCE A.Complywithmanufacturer’swritteninstructionstomaintaininstalledproduct.
EXTRAMATERIALSA.ProvidemaintenancematerialsinaccordancewithSection[017800-CloseoutSubmittals][______].
1.09
1.010
1.011
1.012
1.013
MA
NU
-SP
EC
®
34
MA
NU
-SP
EC
®
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
PART 2 PRODUCTS
MANUFACTURERS A.Ensuremanufacturehasminimum[5][______]yearsexperienceinmanufacturingcomponentssimilarto orexceedingrequirementsofproject.
SpecifierNote:Retainarticlebelowforproprietarymethodspecification.Addproductattributes,performancecharacteristics,materialstandardsanddescriptionsasapplicable.Useofsuchphrasesas“orequal”or“orapprovedequal”orsimilarphrasesmaycauseambiguityinspecifications.Suchphrasesrequireverification(procedural,legalandregulatory)andassignmentofresponsibilityfordetermining“orequal”products.
SHEETMETALROOFS,SOFFITS,WALLPANELS,TILES A.Manufacturer:PetersenAluminumCorp. 1.Contact:1005TonneRd.,ElkGroveVillage,IL60007;Telephone:(800)323-7960,(847)228-7150; Fax:(800)722-7150;website:www.pac-clad.com.
B.ProprietaryProducts/Systems:
SpecifierNote:Ifmorethanonemetalpanelproductisrequiredfortheproject,copyandeditthefollowingarticlesasrequiredandidentifymetalpanelsandothervariablesinascheduleattheendofPart3ofthissection.
1.RoofPanels[RP-1][______]: a.PanelDescription:[TITE-LOC][TITE-LOCHS][TITE-LOCPLUS]. 1)Width:[12inches(305mm)][16inches(406mm)]18inches(457mm)]. 2)Height:2inches(51mm). b.PanelDescription:SNAP-CLADStandingSeam. 1)Width:[10inches(254mm)][12inches(305mm)][16inches(406mm)][18inches(457mm)]. 2)Height:13/4inches(45mm). c.PanelDescription:SNAP-ONStandingSeam. 1)Width:[12inches(305mm)][16inches(406mm)][18inches(457mm)][20inches(508mm)]. 2)Height:1inch(25.4mm). d.PanelDescription:HighSNAP-ONStandingSeam. 1)Width:[11inches(279mm)][18inches(457mm)][19inches(483mm)]. 2)Height:11/2inches(38.1mm). e.PanelDescription:SNAP-ONBatten. 1)Width:[11inches(279mm)][12inches(305mm)][18inches(457mm)]. 2)Height:11/2inches(38.1mm). f.PanelDescription:Redi-RoofStandingSeam. 1)Width:[12inches(305mm)][16inches(406mm)][18inches(457mm)][20inches(508mm)]. 2)Height:19/16inches(40mm). g.PanelDescription:Redi-RoofBatten. 1)Width:12inches(305mm). 2)Height:11/4inches(32mm). h.Material:[22gauge(0.85mm)hot-dippedgalvanizedsteel][24gauge(0.70mm)]hot-dipped galvanizedsteel][0.032inch(0.81mm)aluminumalloy3105-H14][0.040inch(1.02mm) aluminumalloy3105-H14][16oz(0.45kg)coldrolledcopper]. i.Type:[Standingseam][Highsnap-onstandingseam][Batten][Withoffsets]. j.Radius:[Concave][Convex]availableinTITE-LOC,SNAP-ONStandingSeamand Redi-RoofBatten. k.Sealant:FactoryappliedandavailableonTITE-LOC,TITE-LOCPLUSandSNAP-CLAD StandingSeam. l.Striations(optional).
2.01
2.02
35
m.StiffeningBeads:[None][1][2][3]manufacturerapplied. n.Texture:[Smooth][Stuccoembossed]. o.TopsidePanelFinish:[Frommanufacturer’sstandardcolors][_____]. p.PanelUndersideFinish:Polyesterwashcoatwithdryfilmthicknessof0.3mil. q.Eavenotched.
2.WallPanels[WP-1][______]: a.PanelDescription:FlushPanel. 1)Width:[7inches(178mm)][11inches(279mm)][18inches(457mm)]. 2)Height:1inch(25.4mm). b.PanelDescription:RevealPanel. 1)Width:[7inches(178mm)][11inches(279mm)][18inches(457mm)]. 2)Height:1inch(25.4mm). c.PanelDescription:M-Panel. 1)Width:[36inches(914mm)][42inches(1067mm)]. 2)Height:3/4inch(19.1mm). d.PanelDescription:R-Panel. 1)Width:[36inches(914mm)][41inches(1041mm)]. 2)Height:11/4inch(32mm). e.PanelDescription:7/8inch(22.2mm)Panel. 1)Width:Variable. 2)Height:11/2inches(38.1mm). f.PanelDescription:1/2inch(12.7mm)Panel. 1)Width:40inches(1016mm). 2)Height:1/2inch(12.7mm). g.PanelDescription:7.2RibPanel. 1)Width:36inches(914mm). 2)Height:11/2inches(38.1mm). h.Material:[22gauge(0.85mm)hot-dippedgalvanizedsteel][24gauge(0.70mm)hot-dipped galvanizedsteel][0.032inch(0.81mm)aluminumalloy3105-H14][0.040inch(1.02mm)aluminum alloy3105-H14]. i.StiffeningBeads:Number[None][1][2][3]manufacturerapplied. j.Texture:[Smooth][Stuccoembossed]. k.Venting:[Non-vented][1row][2rows]availableonFlushPanels. l.TopsidePanelFinish:[Frommanufacturer’sstandardcolors][_____]. m.PanelUndersideFinish:Polyesterwashcoatwithdryfilmthicknessof0.3mil.
3.SoffitPanels[SP-1][_____]: a.PanelDescription:FlushPanel. 1)Width:[7inches(178mm)][11inches(279mm)]. 2)Height:1inch(25.4mm). 3)Material:[22gauge(0.85mm)hot-dippedgalvanizedsteel][24gauge(0.70mm)]hot-dipped galvanizedsteel][0.032inch(0.81mm)aluminumalloy3105-H14][0.040inch(1.02mm)aluminum alloy3105-H14]. b.PanelDescription:RevealPanel. 1)Width:[7inches(178mm)][11inches(279mm)]. 2)Height:1inch(25.4mm). 3)Material:[22gauge(0.85mm)hot-dippedgalvanizedsteel][24gauge(0.70mm)]hot-dipped galvanizedsteel][0.032inch(0.81mm)aluminumalloy3105-H14][0.040inch(1.02mm)aluminum alloy3105-H14]. c.PanelDescription:PAC-750SoffitPanel. 1)Width:12inches(305mm).
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
MA
NU
-SP
EC
®
36
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
MA
NU
-SP
EC
®
2)Height:1/2inch(12.7mm). 3)Material:0.032inch(0.81mm)aluminumalloy3105-H14. d.PanelDescription:PAC-850SoffitPanel. 1)Width:12inches(305mm). 2)Height:1/2inch(12.7mm). 3)Material:0.032inch(0.81mm)aluminumalloy3105-H14. e.StiffeningBeads:Number[None][1][2][3]manufacturerapplied. f.Texture:[Smooth][Stuccoembossed].
SpecifierNote:RetainarticlebelowtospecifyventingoptionsforPAC-750SoffitorPAC-850Soffitpanels.
g.Venting:[FullVent][HalfVent].
SpecifierNote:RetainarticlebelowtospecifyventingoptionsforFlushpanels.
h.Venting:[Non-vented][1row][2rows]. i.TopsidePanelFinish:[Frommanufacturer’sstandardcolors][_____]. j.PanelUndersideFinish:Polyesterwashcoatwithdryfilmthicknessof0.3mil.
4.Tiles[TP-1][_____]: a.Material:[Coppercoated][Zinc-titanium]. b.TileDimension:393/8inches×133/8inches(1000×340mm). c.AcceptableMaterial:PetersenAluminumCorp.Pac-CladTegola[PrestigeElite][PrestigeCompact] [PrestigeTraditional][ZTCompact][ZTPrestigePre-PatinaElite][ZTPrestigePre-PatinaCompact] Tiles.
5.FlashingandTrim: a.Material:[0.033inch(0.85mm)hot-dippedgalvanizedsteel][0.027inch(0.70mm)]hot-dipped galvanizedsteel][[0.032inch(0.81mm)][0.040inch(1.02mm)][0.051inch(1.29mm)][0.064inch (1.63mm)][0.080inch(2.05mm)]alloy3105-H14aluminum][16oz(0.45kg)coldrolledcopper]. b.Profiles:[Tomanufacturer’sstandardflashingandtrimprofiles][Asdetailed][_____]. c.[Colorandfinishtomatch[Roof][Wall][Soffit][Tile]panels][_____].
SOURCEQUALITYCONTROL A.Ensurecladding/roofingcomponentsandmaterialsarefromsinglemanufacturer.
SpecifierNote:EditParagraphbelowtosuitprojectrequirements.Ifsubstitutionsarepermitted,edittextbelow.AddtexttorefertoSection012513-ProductSubstitutionProcedures.
PRODUCTSUBSTITUTIONS A.Substitutions:[InaccordancewithSection012513-ProductSubstitutionProcedures][______][No substitutionspermitted].
PART 3 EXECUTION
MANUFACTURER’SINSTRUCTIONS
SpecifierNote:ArticlebelowisanadditiontotheCSISectionFormatandasupplementtoMANU-SPEC.Revisearticlebelowtosuitprojectrequirementsandspecifier’spractice.
A.Compliance:Complywithmanufacturer’swrittendata,includingproducttechnicalbulletins,product cataloginstallation
2.03
2.04
3.01
37
A.instructions,productcartoninstallationinstructionsandPetersenAluminumCorp.PAC-CLAD SPEC-DATAsheets.
EXAMINATION A.SiteVerificationofConditions: 1.Verifythatsubstrateconditions,whichhavebeenpreviouslyinstalledunderothersectionsorcontracts,are acceptableforproductinstallationinaccordancewithmanufacturer’sinstructionspriortoinstallationof [Roof][Wall][Soffit][Tile]panels.
PREPARATION A.Ensuresurfacesarecleanandfreeofdirtandotherforeignmatterharmfultoperformanceof[Roof][Wall] [Soffit][Tile]materials.
B.Removemanufacturer’sprotectivefilmfrompanelsurfaces.
C.Coordinatepanelinstallationwithworkofothertradestoprovideanoncorrosiveandleakproofinstallation.
D.Preventgalvanicactionofdissimilarmetalsinproximitytooneanother.
INSTALLATION
SpecifierNote:Coordinateinstallationwiththemanufacturer’swritteninstallationdetailsandinstructions.
A.Seams:Provideuniform,neatseams.
B.Fasteners:Concealfastenerswherepossibleinexposedwork.Coverandsealfastenersandanchorsfor watertightandleakproofinstallation.
C.Sealant-TypeJoints:Providesealant-typejointwhereindicated.Formjointstoconcealsealant.
FIELDQUALITYCONTROL
SpecifierNote:UsethefollowingArticlesonlywhenmanufacturer’sfieldservicesaredesiredtoverifythequalityoftheinstalledcomponents.Establishthenumberanddurationofperiodicsitevisitsrequiredbymanufacturerandspecifybelow.Consultmanufacturerforservicesrequired.Deleteiffieldservicesarenotrequired.
A.HavemanufacturerofproductssuppliedunderthisSectionreviewworkinvolvedinhandling, installation/application,protectionandcleaningofitsproduct(s),andsubmitwrittenreportsinacceptable formattoverifycomplianceofworkwithContract.
B.Manufacturer’sFieldServices:Providemanufacturer’sfieldservicesconsistingofproductuse recommendationsandperiodicsitevisitsforinspectionofproductinstallationinaccordancewith manufacturer’sinstructions.
C.ScheduleSiteVisitstoReviewWorkatStagesListed: 1.Afterdeliveryandstorageofproducts,andwhenpreparatoryWorkonwhichWorkofthisSectiondepends iscomplete,butbeforeinstallationbegins. 2.[Twice][______]duringprogressofWorkat[25%][______]and[60%][______]complete. 3.UponcompletionofWork,aftercleaningiscarriedout.
D.Obtainreportswithin[3][______]daysofreviewandsubmit.
3.02
3.03
3.04
3.05
MA
NU
-SP
EC
®
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
38
MA
NU
-SP
EC
®
TESTINGANDVERIFICATION A.Performtestsrecommendedandrequiredbymanufacturertoverifyrequiredperformanceofpanelsystem, undersupervisionandmonitoringprocessofaccreditedanddesignateddesignengineer.
B.Performandmeettestsrequiredby[Owner][Architect][Consultant][Authoritieshavingjurisdiction][______].
FINALCLEANING A.DocleanupinaccordancewithSection[017400-CleaningandWasteManagement][______].
B.Uponcompletion,removesurplusandexcessmaterials,rubbish,toolsandequipment.
PROTECTION
SpecifierNote:CoordinatethefollowingArticlewithSection017600-ProtectingInstalledConstruction.
A.ProtectinstalledproductfromdamageduringconstructioninaccordancewithSection[017600-Protecting InstalledConstruction][______].
SCHEDULE
SpecifierNote:Includeascheduleofpaneltypesandlocationstosuitprojectrequirements.
A.RoofPanelTypeRP-1:[Location].
B.RoofPanelTypeRP-2:[Location].
C.WallPanelTypeWP-1:[Location].
D.SoffitPanelTypeSP-1:[Location].
E.TileTypeTP-1:[Location].
ENDOFSECTION
3.06
3.07
3.08
3.09
SPEC-DATA®andMANU-SPEC®areregisteredtrademarksofReedElsevierInc.ThethreepartMANU-SPECformatconformstotheeditorialstyleofTheConstructionSpecificationsInstituteandisusedwiththeirpermission.Themanufacturerisresponsiblefortechnicalaccuracy.©2007ReedConstructionData.AllRightsReserved.
PETERSEN ALUMINUM CORPORATION www.pac-clad.com/ email:[email protected]
HQ:1005TonneRoadElkGroveVillage,IL60007P:800-PAC-CLADF:800-722-7150
9060JunctionDriveAnnapolisJunction,MD20701P:800-344-1400F:301-953-7627
10551PACRoadTyler,TX75707P:800-441-8661F:903-581-8592
102NorthpointPkwyExt,Bldg1,Ste100Acworth,GA30102P:800-272-4482F:770-420-2533
35073rdAve.,NE,Ste1Fridley,MN55432P:877-571-2025F:866-901-2935