Thrane & Thrane NMEA Adapter Manual

26
TT-3606E Opt. 003 NMEA Adapter Installation & User Manual 1/26 SAILOR® by Thrane & Thrane TT-3606E Opt. 003 NMEA Adapter Installation & User Manual Copyright© Thrane & Thrane A/S ALL RIGHTS RESERVED 2007, Thrane & Thrane A/S Information in this document is subject to change without notice and does not represent a commitment on the part of Thrane & Thrane A/S. Document number: 98-124401 Revision: B Release Date: 11 th of September 2008

Transcript of Thrane & Thrane NMEA Adapter Manual

Page 1: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

1/26

SAILOR® by Thrane & Thrane

TT-3606E Opt. 003 NMEA Adapter

Installation & User Manual

Copyright© Thrane & Thrane A/S ALL RIGHTS RESERVED

2007, Thrane & Thrane A/S

Information in this document is subject to change without notice and does not represent a commitment on the part of Thrane & Thrane A/S. Document number: 98-124401 Revision: B Release Date: 11th of September 2008

Page 2: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

2/26

This page is intentionally left blank

Page 3: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

3/26

SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of the equipment. Thrane & Thrane A/S assumes no liability for the customer’s failure to comply with these requirements. KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove equipment covers. Only qualified maintenance personal must make component replacement and internal adjustment. Under certain conditions, dangerous voltages may exist even with the cable removed. To avoid injuries, always disconnect power and discharge circuits before touching them.

Page 4: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

4/26

This page is intentionally left blank

Page 5: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

5/26

List of Contents: 1 Introduction ........................................ 7

1.1 Initial Inspection .......................................................7 1.2 Storage.....................................................................7 1.3 Repacking for shipment............................................8 1.4 Additional manuals...................................................8 1.5 Abbreviations...........................................................9

2 System Description............................. 10 2.1 TT-3606E Opt. 003 NMEA Adapter.......................... 10

3 System Installation ............................. 12 3.1 Installation of the NMEA Adapter............................ 13

3.1.1 Mounting of The NMEA Adapter ...................... 14 3.1.2 Handling of wire terminals............................... 17 3.1.3 Connecting power to The NMEA Adapter ........ 17 3.1.4 Wiring NMEA signals....................................... 19

4 Test of the system............................... 22 4.1 Verification of correct power supply ...................... 22 4.2 Verification of NMEA IN data .................................. 23 4.3 Verification of NMEA OUT data............................... 23

5 Maintenance guidelines ...................... 24 6 Appendix A Technical Specification ...... 25

Page 6: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

6/26

List of Figures: Figure 1 TT-3000E mini-C GMDSS System overview ............ 10 Figure 2 TT-3606E Opt. 003 NMEA Adapter ......................... 11 Figure 3 Outside view of TT-3606E OPT. 003 NMEA Adapter 13 Figure 4 Inside view of TT-3606E OPT. 003 NMEA Adapter.. 13 Figure 5 Free space around the NMEA Adapter................... 14 Figure 6 Drill template. All measures in mm. ....................... 15 Figure 8 Power cable connections. ...................................... 18 Figure 9 Talker and listener labelling .................................. 19 Figure 10 Wiring of NMEA Talker & Listener ....................... 20 Figure 11 TT-3606E OPT. 003 NMEA Adapter LED location. . 22 List of Tables: Table 1 TT-3606E Opt. 003 NMEA Adapter Technical

Specification ................................................................. 25

Page 7: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

7/26

1 INTRODUCTION This manual provides instructions for installing a TT-3606E Opt. 003 NMEA Adapter to a TT-3000E mini-C GMDSS System.

1.1 INITIAL INSPECTION

Inspect the shipping carton immediately upon receipt for evidence of damage during the transport. If the shipping carton is severely damaged or water stained, request the carrier's agent to be present when opening the carton. Save the carton packing material for future use.

Contents of the shipment should be as listed in the enclosed packing list. If the contents are incomplete, if there is mechanical damage or defect, or if the system components do not work properly, notify your dealer. After you unpack the system please: • Inspect it thoroughly for hidden damaged, loose

components or loose fittings. • Inspect the cable harness for stress, loose or broken

wires, or broken cable ties. • Examine all the components for loose or missing

hardware. • Tighten all loose hardware.

1.2 STORAGE

The TT-3606E Opt. 003 NMEA Adapter may be stored or shipped in temperatures within the limits -40° C to +80° C. It is

WARNING To avoid hazardous electrical shock, do not perform electrical tests if there is any sign of shipping damage to any portion of the outer cover. Read the safety summary at the front of this manual before installing or operating the TT-3606E Opt. 003 NMEA Adapter.

Page 8: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

8/26

recommended that the system is unpacked immediately on delivery.

1.3 REPACKING FOR SHIPMENT

The shipping carton for the TT-3606E Opt. 003 NMEA Adapter has been carefully designed to protect the equipment during shipment. The carton and its associated packing material should be used when repackaging for shipment. Attach a tag indicating the type of service required, return address and model number. Mark the carton FRAGILE to ensure careful handling. If the original shipping carton is not available, the following general instructions should be used for repackaging with commercially available material. • Wrap the equipment in heavy paper or plastic. Attach a

tag indicating the type of service required, return address and model number.

• Use a strong shipping container, e.g., a double-walled carton made of 160 kg test material.

• Seal the shipping container FRAGILE to ensure careful handling.

1.4 ADDITIONAL MANUALS

Ref. T&T number Title [1] TT 98-122414 TT-3000E mini-C GMDSS System

Installation Manual

[2] TT 98-122464 TT-3000E mini-C GMDSS System User Manual

[3] TT 98-122650 TT3000E SSAS Installation Manual

Page 9: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

9/26

1.5 ABBREVIATIONS

GMDSS Global Maritime Distress and Safety System GPS Global Positioning System LED Light Emitting Diode Opt. Short for option SSAS Ship Security Alert System

Page 10: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

10/26

2 SYSTEM DESCRIPTION An overview of the complete TT-3000E mini-C GMDSS System is shown in Figure 1.

Figure 1 TT-3000E mini-C GMDSS System overview

Detailed information concerning the TT-3000E mini-C GMDSS System (with SSAS) can be found in ref. [1], [2] and [3]. This manual only holds detailed information about the TT-3606E Opt. 003 NMEA Adapter

2.1 TT-3606E OPT. 003 NMEA ADAPTER

For interfacing NMEA signals to the TT-3000E mini-C GMDSS System, the TT-3606E Opt. 003 NMEA Adapter is used. It is designed to be located inside a vessel close to the TT-3606E Message Terminal.

It includes one NMEA talker port and one NMEA listener port. The listener port is galvanic isolated from ground (according to IEC 61162-1 & IEC 61162-2). The ports can operate at baud

Page 11: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

11/26

rates up to 38400, but the baud rate must be the same on both channels.

Figure 2 TT-3606E Opt. 003 NMEA Adapter

IMPORTANT NOTICE: The GPS data transmitted on the NMEA output (Talker) is meant to be used for date, time and position information for other GMDSS systems without internal GPS. An example of such systems could be VHF and MF/HF radios with DSC. The data is NOT meant to be used for navigational purpose. Although repeated approximately every second, the content of the NMEA sentences are only updated every 30 seconds.

Page 12: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

12/26

3 SYSTEM INSTALLATION This chapter provides specific information enabling you to install the TT-3606E Opt. 003 NMEA Adapter on a TT-3000E mini-C GMDSS System with a minimal effort. The default, or factory configuration, is described together with procedures for altering this configuration. The TT-3606E Opt. 003 NMEA Adapter connects to the TT-3000E mini-C GMDSS system using a standard RS232 cable with DSUB9 connectors (male/female) connected to COM2 on the TT-3606E Message Terminal.

Page 13: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

13/26

3.1 INSTALLATION OF THE NMEA ADAPTER

The TT-3606E Opt. 003 NMEA Adapter is designed to facilitate a simple and robust interconnection to various external NMEA based system components.

Figure 3 Outside view of TT-3606E OPT. 003 NMEA Adapter

Figure 4 Inside view of TT-3606E OPT. 003 NMEA Adapter

Page 14: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

14/26

3.1.1 MOUNTING OF THE NMEA ADAPTER

The TT-3606E OPT. 003 NMEA Adapter is designed to be mounted on a flat surface anywhere inside a vessel and to be located within a few meters from the TT-3606E Message Terminal. In case the power supply originates from the +9VDC output of the TT-3616C Interconnection Box the distance from this box should also be kept within a few meters. In order to ease the installation, please observe the minimum clearing area as given in Figure 5.

** m

inim

um 1

00 m

m.

* 50

mm

.

Figure 5 Free space around the NMEA Adapter.

Page 15: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

15/26

The unit must be fastened by the used of 4 screws, one in each corner of the chassis as indicated by Figure 6. The accessories for TT-3606E OPT. 003 NMEA Adapter include 2 different types of screws for the purpose, M5x12 and 5.5x25.

Figure 6 Drill template. All measures in mm.

The best grounding is made by fixing the chassis directly on to the ships structure (provided it’s made of metal). If proper grounding can not be made this way, then connect the pre-mounted grounding wire to the ships structure. Find an appropriate location as close as possible to the TT-3606E OPT. 003 NMEA Adapter and shorten the grounding wire accordingly. Terminate the grounding wire with the yellow ring terminal found in the accessory kit. The correct (pre-mounted) position of the grounding wire can be seen on Figure 4. Please note the use of a washer underneath the yellow ring terminal. The grounding wire delivered with the TT-3606E OPT. 003 NMEA Adapter has a length of 1 meter and a wire cross section of 4mm2. Avoid extending the length of the grounding

Page 16: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

16/26

wire, as the protective effect will be severely degraded in such a case.

Page 17: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

17/26

3.1.2 HANDLING OF WIRE TERMINALS

To help inserting wires into the terminals, a special tool is delivered as part of the accessory kit. It is used as shown in Figure 7 (the picture shows another unit, but the principle remains the same).

Please be careful not to apply to much pressure, as this might

damage the top of the terminal housing. In case the special tool is lost, a small screwdriver can be used as well.

3.1.3 CONNECTING POWER TO THE NMEA ADAPTER

The TT-3606E OPT. 003 NMEA Adapter is designed to operate on DC in the range 8 - 32 V. As “DC-“ is connected directly to GND (Chassis), the supply to the TT-3606E Opt. 003 NMEA Adapter must be taken directly from the +9VDC output on the TT-3616C Interconnection Box. This ensures correct operation even during switch over to battery operation during an AC failure situation. When connecting the power supply cable to TT-3606E OPT. 003 NMEA Adapter, make sure the cable screen is properly terminated at the cable relief bracket as shown in Figure 8. Connect the positive supply wire to the terminal denoted “DC+” and the negative supply wire to the terminal denoted “DC-“. Do not connect the cable screen at the other end of the cable.

Figure 7 Wire tool

Page 18: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

18/26

Figure 8 Power cable connections.

When power is switched on, the green LED denoted “POWER OK” should be turned on. The current drawn will range from around 30mA when used as a listener only. When the talker is active, the current drawn can be up to 130mA when fully loaded.

Page 19: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

19/26

3.1.4 WIRING NMEA SIGNALS

The TT-3606E Opt. 003 NMEA Adapter has one talker port (labelled “NMEA OUT”) and one listener port (labelled “NMEA IN”). The labelling is shown in Figure 9.

Figure 9 Talker and listener labelling

To ease wiring there are 2 terminals for each signal. They are internally connected to each other as can be seen in Figure 10. In case the listener is placed at the end of the cable and the baud rate is higher than 4800 baud, it is recommended to terminate the cable. Provided the impedance of the cable is around 120Ω, an internal 120Ω resistor can be enabled by connecting jumper W1.

Page 20: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

20/26

Figure 10 I/O Schematic

The recommended cabling principles are shown in Figure 11.

Figure 11 Wiring of NMEA Talker & Listener

As can be seen from Figure 11 it is important to avoid getting the cable shield in contact with the chassis when connecting wires to the listener input.

Page 21: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

21/26

When connecting equipments with only A and B terminals (IEC 61162-1 equipment), simply leave the C terminal unconnected. IMPORTANT NOTICE: The TT-3606E Opt. 003 NMEA Adapter Listener (NMEA IN) is not compatible with old unbalanced NMEA 0183 talkers characterised by VA ≥ VB at all times (VA = voltage at terminal A etc.). Talkers compliant to IEC 61162-1 and/or IEC 61162-2 will interface without problems.

Page 22: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

22/26

4 TEST OF THE SYSTEM This section provides information on how to perform system checks as well as help for troubleshooting. Concerning the initial start up and use of the TT-3606E Message Terminal, please refer to the user manual, ref. [1]. Remember to enable the NMEA functionality (TT-3606E menu path: <Application><System><Options><Serial ports>).

4.1 VERIFICATION OF CORRECT POWER SUPPLY

The TT-3606E Opt. 003 NMEA Adapter has one light emitting diode (LED) to provide basic installation and troubleshooting help. The location of the LED is shown in Figure 12.

Figure 12 TT-3606E OPT. 003 NMEA Adapter LED location.

When applying power to the TT-3606E OPT. 003 NMEA Adapter, the “DC in” LED will light up. In case the LED does not light up, then:

1) Check the wiring. 2) Check the power supply source.

Page 23: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

23/26

4.2 VERIFICATION OF NMEA IN DATA

As the NMEA IN data are used solely to form an additional position data string in the SSAS message, simply send a SSAS Test Message to verify the correctness of data. Refer to the TT-3000E SSAS Installation Manual for further information, ref. [3]. Be aware, that the additional position data string in the SSAS Message is only updated every 30 seconds.

4.3 VERIFICATION OF NMEA OUT DATA

Verification of correct NMEA output data should be done by checking that each listener device receives the appropriate information according to their needs. Be aware, that although the NMEA sentences are repeated approximately every second, the content is only updated every 30 second.

Page 24: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

24/26

5 MAINTENANCE GUIDELINES When properly installed the TT-3606E Opt. 003 NMEA Adapter needs no maintenance.

Page 25: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

25/26

6 APPENDIX A TECHNICAL SPECIFICATION Appendix A holds the technical specification for the TT-3606E Opt. 003 NMEA Adapter.

Model TT-3606E Opt. 003 NMEA Adapter General Specifications The unit is approved by Inmarsat and in

full compliance with IEC 60945 and Wheel Mark specifications.

Dimensions (H x W x D) 46 mm x 198 mm x 104 mm Weight 0.5 Kg Mountings Wall mounting, 4 holes Ø6 mm Power requirements Floating DC.

Can be taken directly from TT-3616C +9V secondary supply or from an isolated external power supply. Nominal voltage range is 9V to 24V. Working voltage range is 8V to 32V. Max current 130mA.

Connector DSUB9 Female. 14 x Spring type terminals (max. 2.5mm2).

Fuse Automatic reset able fuse Temperature -25°C to 55°C operating,

-40°C to 80°C storage Relative humidity 95% non-condensing at 40°C Vibration operational Random vibrations: 5-20 Hz:0.005 g²/Hz

20-150 Hz:-3 dB/oct (0.5 g rms.) Sinusoidal vibrations: 2-15.8 Hz: 2.54 mm peak ampl. 10-100 Hz: 1.0 g peak acceleration

Vibration survival Random vibrations: 5-20 Hz:0.05g²/Hz 20-150 Hz:-3 dB/oct (1.7g rms.) Sinusoidal vibrations: 2-15.8 Hz:2.54 mm peak ampl. 10-100 Hz: 1.0g peak acceleration

Shock Half sine: 20g/11ms Talker performance Capable of driving up to 8 listeners at

baud rates up to 38400 baud.

Listener characteristics Input resistance > 12kΩ. Compatible with IEC 61162-1 and IEC 61162-2 talkers, but not old NMEA 0183 talkers.

Table 1 TT-3606E Opt. 003 NMEA Adapter Technical Specification

Page 26: Thrane & Thrane NMEA Adapter Manual

TT-3606E Opt. 003 NMEA Adapter Installation & User Manual

26/26

+++