THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge...

9

Transcript of THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge...

Page 1: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 2: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 3: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 4: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 5: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.

  THP WAS only THP I-THPCambi own IP

Typical application Intensive digestion for new builds and sludge centres

Partial intensification / class B sludge

Lazy existing digester capacity, Class A cake,

Increased energy production

VS loading <8 kgVS/m3/d< 621 lb.VS/1,000 ft3

3-5 kgVS/m3/d233-388 lb.VS/1,000 ft3

3-4 kgVS/m3/day233-311 lb.VS/1,000 ft3

Energy balance >80% of biogas to CHP 100% on waste heat 100% on waste heat

THP size 100% ~50% ~60%

Typical %DS of cake 30-45% 25-40% 34-50%

Typical VSR 52-65% 52-60% 60-70%

Electrical Output (MWh/TDS) 0.97 0.90 1.07

Operational /        in construction 40 3 1 (pilot)

Page 6: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 7: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.

Cambi Solidstream® Technology

BiogasFinal

dewatering

(no polymer)100°

C

Sludge cake

> 60% DS

Pre dewatering

Reject water to

main WWTP

Thickened

Sludge

5% DS

Conventional

digester

45% VSR

SolidStream®

Hydrolysate (soluble COD) to digester

CHPElectricity

+ 15 – 30% gas from

THP hydrolysate

17% DS

Steam

< 500 kg/tonDS

Page 8: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.
Page 9: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.

SolidStream® Standardised Design

60 tds/day - 3 x SolidStream®

System is easily configured with 1, 2 or 3 lines.

All units are standardized for reducing risk in projects.

System based on module design.