The Centrifuges 5804 / 5804 R and 5810 / 5810 R · 3 *1 Dazzling with excellent versatility...

32
Performance you can count on The Centrifuges 5804 / 5804 R and 5810 / 5810 R High Versatility

Transcript of The Centrifuges 5804 / 5804 R and 5810 / 5810 R · 3 *1 Dazzling with excellent versatility...

Performance you can count onThe Centrifuges 5804 / 5804 R and 5810 / 5810 R

HighVersatility

2

*1

Our four stars continue to shine

Featuring powerful, maintenance-free motors, these centrifuges accommodate a variety of rotors to meet your application needs. They are three centrifuges in one: a high-capacity, general-purpose centrifuge for cell harvesting; a high-speed centrifuge for separating cell lysates; and a microcentrifuge for DNA precipitations.

For lower capacity needs in one compact unit, Centrifuge 5804 (refrigerated: 5804 R) spins plates and tubes from 0.2 mL to 4 × 100 mL at low-to-high speeds for a wide range of applications. These compact centrifuges can accommodate capacities of up to 16 × 15 mL conical (Falcon®) or 30 microcentrifuge tubes per run.

Centrifuge 5810 (refrigerated: 5810 R) offers maximum application versatility and popular tube capacity, accommodating up to 4 × 500 mL tubes or 16 microplates. These compact, benchtop centrifuges achieve remarkable throughput of up to 48 × 15 mL or 20 × 50 mL conical (Falcon®) tubes.

Centrifuges 5804/5804 R and 5810/5810 R

‡ Centrifuge 5804 R with Rotor A-4-44 ‡ Centrifuge 5804 with Rotor A-2-DWP

3

*1

Dazzling with excellent versatility

Centrifuges 5804/5804 R and 5810/5810 R

Technical specifi cations and ordering information see page 30, 32.

‡ Interchangeable swing-bucket and high-speed fi xed-angle rotors‡ Max. capacity of 400 mL (5804 / 5804 R) or 2,000 mL (5810 / 5810 R)‡ Spin up to 20,800 × g or 14,000 rpm‡ Broad range of adapters and modular accessories

‡ “at set rpm” function: Timer starts when set speed is reached for more reproducible results

‡ Simple programming of time, temperature (refrigerated models), g-force/speed and radius values

‡ 35 individual user programs‡ Adjustable speed‡ Short Spin button

‡ Low access height (28 cm)‡ Motorized lid locking‡ Automatic rotor recognition‡ Imbalance cutout‡ Powerful motors for short acceleration and brake times‡ 10 different acceleration and braking rates

‡ Temperature range from –9 °C to +40 °C‡ Rotors can be spun at maximum speed and still maintain 4 °C

(Except Rotor F-34-6-38 and Rotor FA-45-6-30 max. speed) (230 V refrigerated versions)

‡ FastTemp function for fast pre-cooling‡ Standby cooling maintains temperature when centrifuge

is not in use‡ ECO shut-off engages after 8 hours of non use to reduce energy

consumption and extend compressor life‡ Built-in condensation drain to eliminate water accumulation and

prevent corrosion

Product features

Interface

Handling and safety

Cooling

‡ Centrifuge 5810 R with Rotor A-4-81

‡ Centrifuge 5810 with Rotor A-4-62-MTP

4

The large back-lit LCD display and easy-to-clean soft keypad comprise the user-friendly “command center” in the 5804 / 5810 series.

The alphanumeric display shows the current operating status at a glance – most parameters can even be changed during centri fugation. A further useful detail: The last user program used stays automatically on display for the currently installed rotor.

Easily input relative centrifugal force (rcf), speed (rpm), radius correction values (rad), and temperature (–9 °C to +40 °C); the short-spin key enables quick runs at your desired rotational speed.

Options for time settings include 10 acceleration and braking ramps to better protect sensitive samples. The FastTemp function, a common feature on popular Eppendorf models, enables rapid pre-cooling of the rotor and centrifuge for runs in the low-temperature ranges.

The operating concept

‡ Speed, rcf, and radius correction values are easily entered‡ Values can be changed during centrifugation‡ Temperature range from –9 to +40 °C*‡ Stand-by refrigeration*‡ Speed can be set from 200 rpm to maximum speed

in increments of 10 rpm

‡ Save up to 35 individual user programs‡ Short-spin key with selectable rotational speed‡ “at set rpm” for even more reproducible results‡ FastTemp function* for rapid cooling of the rotor chamber‡ 10 acceleration and braking ramps for added protection

of sensitive sample material

* Refrigerated Centrifuges 5804 R and 5810 R only.

User-friendly operation

We kept it smart, but made it simple

5

Always a perfect fit

The operating concept

‡ Adapters allow most commercially available tubes to be centrifuged in our swing-bucket rotors

‡ Flexible modular design: different tube lengths fit into one adapter

‡ Stable on the benchtop; makes them well suited for the processing and preparation of series of samples

‡ Fully autoclavable (20 min, 121 °C)‡ Easy to disassemble and clean

Simple adapters for swing-bucket rotors The modular construction of most adapters for our 5804 / 5810 series swing-bucket rotors allow centrifugation of practically all commercially available tubes. Stack adapter modules to your required height and simply lower them onto the holders in the rectangular buckets. Additional exchangeable swing-buckets for MTPs and 50 mL Falcon® tubes can be combined with the rotor crosses and open up even more application options.

The stable plastic adapters are solidly constructed and can be easily cleaned. They can even be autoclaved in their entirety in the event of contamination with biologically active sample material.

6

Approximate braking times for different rotors at levels 0 to 9 (in seconds) for 230 V* centrifuges

5804/ 5804 R

5810/ 5810 R

Max. volume

Rotor 0 1 2 3 4 5 6 7 8 9

– ‡ 4 × 500 mL A-4-81 532 189 174 143 131 109 95 85 59 31

– ‡ A-4-81-MTP/Flex 643 191 174 142 131 110 94 83 58 30

– ‡ 4 × 250 mL A-4-62 740 190 170 140 130 110 95 85 55 26

– ‡ A-4-62-MTP 620 190 170 140 130 110 95 85 55 26

‡ ‡ 4 × 100 mL A-4-44 470 300 270 220 200 140 100 75 45 23

‡ ‡ A-2-DWP 304 174 130 118 100 75 51 44 32 14

‡ ‡ 6 × 85 mL F-34-6-38 880 370 280 190 170 150 125 95 75 54

‡ ‡ 30 × 1.5/2.0 mL FA-45-30-11 240 140 70 45 35 30 25 22 19 18

‡ ‡ 30 × 1.5/2.0 mL F-45-30-11 240 140 70 45 35 30 25 22 19 18

‡ ‡ 48 × 0.2 mL F-45-48-PCR 169 119 60 41 31 26 22 19 17 16

‡ ‡ 60 × 2.0 mL T-60-11 800 280 140 95 70 55 45 40 36 36

The given times are to be considered guidelines. While level 9 means “strongest braking,” level 0 means “free deceleration,” whereby considerable fl uctuations can occur with this uncontrolled deceleration, depending upon the condition of the device and the load.

*The deceleration times for the 230 V and 120 V devices are almost identical.

Centrifuges 5804 (refrigerated version 5804 R) and 5810 (refrigerated version 5810 R) together with the high-performance,

high-capacity swing-bucket rotors accommodate virtually all commercially available tubes from 0.2 mL to 500 mL.

Performance data

5804/5804 R 5810/5810 R Rotor Max. capacity

Max. rcf (× g)

Max. rotational speed (rpm)

Max. radius (cm)

Lowest attainable temperature at max. rpm*1

Max. rpm for tem perature at 4 °C*1

Max. load per bucket/bore*2

Max. loading height for plate buckets

Aerosoltight centri fu gation possible*3

Swing-bucket rotors

– ‡ A-4-81*4 4 × 500 mL 3,250 4,000 18.0 < 4 °C 4,000 780 g – ‡

– ‡ A-4-81-MTP/Flex*4 4 × 4 MTP 2,900 4,000 16.3 < 0 °C 4,000 380 g 60 mm –

– ‡ A-4-62*5 4 × 250 mL 3,200 4,000 18.0 ≤ 2 °C 4,000 630 g – ‡

– ‡ A-4-62-MTP*5 4 × 3 MTP 2,750 4,000 15.4 < 0 °C 4,000 380 g 53 mm –

‡ ‡ A-4-44 4 × 100 mL 4,500 5,000 16.1 ≤ 4 °C 5,000 310 g – ‡

‡ ‡ A-2-DWP 2 × 5 MTP 2,250 3,700 14.7 < 0 °C 3,700 380 g 89 mm –

Fixed-angle rotors

‡ ‡ F-34-6-38 6 × 85 mL 18,500 (5810 R only)

12,000 (5810 R only)

11.5 9 °C 11,000 125 g – –

15,500 11,000 ≤ 4 °C 11,000

‡ ‡ FA-45-30-11 30 × 1.5/2.0 mL 20,800 14,000 9.5 ≤ 3 °C 14,000 3.75 g – ‡

‡ ‡ F-45-30-11 30 × 1.5/2.0 mL 20,800 14,000 9.5 ≤ 3 °C 14,000 3.75 g – –

‡ ‡ F-45-48-PCR 6 × 5/8 PCR strips (48 × 0.2 mL)

15,350 12,000 9.5 1 °C 12,000 6 × 3.5 g – –

Drum rotor

‡ ‡ T-60-11 60 × 1.5/2.0 mL 16,400 14,000 7.5 < 2 °C 14,000 6 × 70 g – –

*1 Refrigerated centrifuges (230 V or 120 V (20 A)) at 23 °C room temperature, after 1 h run.

*2 Adapter + tubes + contents

*3 Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology & Research in Porton Down, CAMR, Great Britain, and according to annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation.

*4 The swing-bucket rotor can be delivered without buckets, equipped with rectangular buckets as an A-4-81 or with MTP/Flex buckets as an A-4-81-MTP/Flex, whereby the MTP/Flex buckets can be purchased separately in sets of 2 or 4. A user-friendly change of rectangular buckets or MTP/Flex buckets is guaranteed by the use of a common rotor cross.

*5 The swing-bucket rotor can be delivered as A-4-62 (loaded with buckets) or as A-4-62-MTP (loaded with plate buckets). User-friendly exchange of rectangular buckets or microtest plate buckets is guaranteed by the use of the all-in-one rotor cross.

F A 45 30 11 A 4 81

7

Performance data

5804/5804 R 5810/5810 R Rotor Max. capacity

Max. rcf (× g)

Max. rotational speed (rpm)

Max. radius (cm)

Lowest attainable temperature at max. rpm*1

Max. rpm for tem perature at 4 °C*1

Max. load per bucket/bore*2

Max. loading height for plate buckets

Aerosoltight centri fu gation possible*3

Swing-bucket rotors

– ‡ A-4-81*4 4 × 500 mL 3,250 4,000 18.0 < 4 °C 4,000 780 g – ‡

– ‡ A-4-81-MTP/Flex*4 4 × 4 MTP 2,900 4,000 16.3 < 0 °C 4,000 380 g 60 mm –

– ‡ A-4-62*5 4 × 250 mL 3,200 4,000 18.0 ≤ 2 °C 4,000 630 g – ‡

– ‡ A-4-62-MTP*5 4 × 3 MTP 2,750 4,000 15.4 < 0 °C 4,000 380 g 53 mm –

‡ ‡ A-4-44 4 × 100 mL 4,500 5,000 16.1 ≤ 4 °C 5,000 310 g – ‡

‡ ‡ A-2-DWP 2 × 5 MTP 2,250 3,700 14.7 < 0 °C 3,700 380 g 89 mm –

Fixed-angle rotors

‡ ‡ F-34-6-38 6 × 85 mL 18,500 (5810 R only)

12,000 (5810 R only)

11.5 9 °C 11,000 125 g – –

15,500 11,000 ≤ 4 °C 11,000

‡ ‡ FA-45-30-11 30 × 1.5/2.0 mL 20,800 14,000 9.5 ≤ 3 °C 14,000 3.75 g – ‡

‡ ‡ F-45-30-11 30 × 1.5/2.0 mL 20,800 14,000 9.5 ≤ 3 °C 14,000 3.75 g – –

‡ ‡ F-45-48-PCR 6 × 5/8 PCR strips (48 × 0.2 mL)

15,350 12,000 9.5 1 °C 12,000 6 × 3.5 g – –

Drum rotor

‡ ‡ T-60-11 60 × 1.5/2.0 mL 16,400 14,000 7.5 < 2 °C 14,000 6 × 70 g – –

*1 Refrigerated centrifuges (230 V or 120 V (20 A)) at 23 °C room temperature, after 1 h run.

*2 Adapter + tubes + contents

*3 Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology & Research in Porton Down, CAMR, Great Britain, and according to annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation.

*4 The swing-bucket rotor can be delivered without buckets, equipped with rectangular buckets as an A-4-81 or with MTP/Flex buckets as an A-4-81-MTP/Flex, whereby the MTP/Flex buckets can be purchased separately in sets of 2 or 4. A user-friendly change of rectangular buckets or MTP/Flex buckets is guaranteed by the use of a common rotor cross.

*5 The swing-bucket rotor can be delivered as A-4-62 (loaded with buckets) or as A-4-62-MTP (loaded with plate buckets). User-friendly exchange of rectangular buckets or microtest plate buckets is guaranteed by the use of the all-in-one rotor cross.

Rotor code: Fixed-angle rotor

Angle of adapter bore

Ø Tube/Adapter Swing-bucket rotor

Ø tube/adapter bore

All Eppendorf® rotors are identifi ed using a simple, alphanumeric format that represents the technical specifi cations in a uniform series of letters and numbers.

Aerosol-tight version

Max. no. tubes/adapters

Max. no. buckets/adapters

Info

Load capacity of the adapters may be reduced if the maximum tube length is exceeded. In this case please be sure to carry out a manual swing test. In addition, the use of tubes with oversized lids can result in a decrease of the load capacity of the adapter. Swing-bucket rotors are delivered with buckets from one weight class. When reordering buckets, please provide the already existing weight class. This is imprinted in the side of the nut, e.g., “86.” Please note the manufacturer specifi cations for the maximum centrifugation capacity of tubes, kits, plates and plate stacks.

8

Rotor family for Centrifuges 5810 and 5810 R

‡ 4 × 500 mL rectangular buckets for high capacity‡ Ideal for medical and biotechnology laboratories:

flexible adapters enable high sample throughput and maximum versatility

‡ Max. rcf: 3,250 × g (max. 4,000 rpm)‡ Lids for aerosol-tight centrifugation* optionally available‡ Buckets, lids, and adapters are autoclavable

(20 min, 121 °C)

* Tested by the Centre for Applied Microbiology & Research, CAMR, Porton Down, Great Britain.

Swing-bucket rotor A-4-81 (4 × 500 mL)

‡ 4-place microplate rotor‡ Swing-bucket rotor A-4-81 can be upgraded with

4 MTP/Flex buckets to the MTP rotor A-4-81-MTP/Flex‡ Accommodates up to 16 microplates, 8 culture plates or

4 deepwell plates ‡ MTP/Flex buckets expand the functional range‡ Max. rcf 2,900 × g (max. 4,000 rpm)

Swing-bucket Rotor A-4-81-MTP/Flex (4 × 4 MTP)

Accessories for A-4-81 / A-4-81-MTP/Flex: Page 11–13, 16–17, 22, 24–25 Ordering information A-4-81 / A-4-81-MTP/Flex: Page 30

The swing-bucket rotors

9

Rotor family for Centrifuges 5810 and 5810 R

‡ All-in-one rotor cross for 4 × 250 mL rectangular buckets and 4 MTP buckets

‡ Swing-bucket rotor with rectangular buckets: max. rcf 3,200 × g (max. 4,000 rpm)

‡ Flexible adapters for a wide range of tubes‡ Rotor, buckets, lids, and adapters

are autoclavable (20 min, 121 °C)‡ Lids for aerosol-tight centrifugation* optionally available

* Tested by the Centre for Applied Microbiology & Research, CAMR, Porton Down, Great Britain.

Swing-bucket rotor A-4-62 (4 × 250 mL)

‡ Swing-bucket rotor A-4-62 can be upgraded with 4 MTP buckets to the MTP rotor A-4-62-MTP

‡ Swing-bucket rotor with MTP buckets: max. rcf: 2,750 × g (max. 4,000 rpm)

‡ For up to 12 microtest plates or 8 culture plates or 4 deepwell plates

Swing-bucket rotor A-4-62-MTP (4 × 3 MTP)

Accessories for A-4-62 / A-4-62-MTP: Page 11–13, 18–19, 23–25Ordering information A-4-62 / A-4-62-MTP: Page 30

10

‡ 4 × 100 mL rectangular buckets for high capacity‡ Max. rcf: 4,500 × g (max. 5,000 rpm)‡ Flexible adapters for a wide range of tubes‡ Lids for aerosol-tight centrifugation* optionally available‡ Rotor, buckets, lids, and adapters are autoclavable

(20 min, 121 °C)‡ Also available with four special buckets

for 2 × 50 mL Falcon® tubes

* Tested by the Centre for Applied Microbiology & Research, CAMR, Porton Down, Great Britain.

Swing-bucket rotor A-4-44 (4 × 100 mL)

Accessories for A-4-44: Page 20–21Ordering information A-4-44: Page 31

Rotor family for Centrifuges 5804 / 5804 R and 5810 / 5810 R

‡ Different combinations of stacked plates can be centrifuged

‡ Commercial nucleic acid purifi cation kits up to a maximum height of 89 mm can be used

‡ Max. rcf: 2,250 × g (max. 3,700 rpm)‡ Rotor and buckets are autoclavable (20 min, 121 °C)

Swing-bucket rotor A-2-DWP (2 × 5 MTP)

Accessories for A-2-DWP: Page 24–25Ordering information A-2-DWP: Page 31

11

‡ To be used with MTP, cell culture, DWP and PCR plates‡ Each bucket has a capacity of 4 MTP plates, 1 PCR plate,

2 culture plates or 1 DWP plate‡ Max. RCF: 2,750 × g (max. 4,000 rpm)

‡ These special MTP/Flex buckets have a wider application range than the standard A-4-62-MTP buckets

‡ Additional to the regular plates capacity the MTP/Flex buckets can be used with IsoRacks.

‡ Max. RCF: 2,900 × g (max. 4,000 rpm)

Swing-bucket MTP for rotor A-4-62

Swing-bucket MTP/Flex for rotor A-4-81

Ordering information: page 30Technical specifi cations: page 23

Ordering information: page 30Technical specifi cations: page 22

Accessories for swing-bucket rotors

12

‡ Safe centrifugation support for glass slides and micro arrays ‡ Maximum of 12 slides per bucket‡ High fl exibility attained with help of novel slot frames, which allow

centrifugation either across or parallel to the rotational direction‡ Max. rcf: 100 × g

Slides adapter CombiSlide for all plate buckets

Accessories for swing-bucket rotors

‡ A permanently safe centrifugation support for the proven IsoRacks

‡ A total of up to 96 test tubes can be used in the swing-bucket rotor A-4-81-MTP/Flex

‡ Two versions for 0.5 mL and for 1.5/2.0 mL test tubes available‡ Max. rcf: 2,700 × g (4,000 rpm)

IsoRack adapter for MTP/Flex buckets

See ordering information for the affordable IsoRack starter set: page 30

Ordering information: Page 30Technical specifi cations: Page 25

13

Accessories for swing-bucket rotors

‡ Safe centrifugation of PCR plates (skirted, unskirted and semi-skirted) in all MTP/DWP rotors in the brochure

‡ Two versions for 96 and 384-well PCR plates available‡ Optimized bores for most commonly available

PCR plates‡ Max. rcf in the A-4-81-MTP/Flex: 2,700 × g (4,000 rpm)

PCR plate adapter for all plate buckets

‡ For swing-bucket rotor A-4-81‡ Can be autoclaved open (20 min, 121 °C)‡ Max rcf: 3,250 × g (4,000 rpm) ‡ Wide neck for easy use

400 mL and 500 mL wide-neck bottle by Eppendorf

Ordering information 400 mL bottle: Page 30

Ordering information: Page 30Technical specifi cations: Page 25

14

Accessories for F-45-30-11/FA-45-30-11: Page 28Ordering information F-45-30-11/FA-45-30-11: Page 31

Rotor family for Centrifuges 5804 / 5804 R and 5810 / 5810 R

‡ 6 places for different tubes (max. tube size: 85 mL)‡ Max. rcf: 15,550 × g (11,000 rpm)‡ When used in Centrifuge 5810 R:

max. rcf: 18,500 × g (max. 12,000 rpm)‡ Conical tubes such as 15 mL and 50 mL Falcon® tubes

can be centrifuged with adapters in the fi xed-angle rotor1)

‡ Rotor, lid, adapters are autoclavable (20 min, 121 °C)

1) Please observe the limits for tube load-bearing capacity as specifi ed by the tube manufacturer.

Fixed-angle rotor F-34-6-38

Accessories for F-34-6-38: Page 26-27Ordering information F-34-6-38: Page 31

‡ 30 places for 1.5/2.0 mL test tubes‡ Max. rcf: 20,800 × g (max. 14,000 rpm)‡ Rotor, lid, and adapters are autoclavable (20 min, 121 °C),

the rotor FA-45-30-11 with lid can even be autoclaved for 2 h at 140 °C, to destroy prion contamination.

‡ High-quality, extremely robust aluminum lid for both rotors‡ Aerosol-tight centrifugation possible with the Rotor FA-45-30-11*

* Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology & Research in Porton Down, CAMR, Great Britain, and according to annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation.

Fixed-angle rotor F-45-30-11 and FA-45-30-11

The fi xed-angle rotors

15

‡ Horizontal centrifugation at high relative centrifugal force

‡ Particularly suitable for low sample quantities‡ For pellet formation at bottom of tube‡ Max. rcf: 16,400 × g (max. 14,000 rpm)

Drum rotor T-60-11

Ordering information T-60-11: Page 31

Rotor family for Centrifuges 5804 / 5804 R and 5810 / 5810 R

‡ PCR strip rotor: max. rcf: 15,350 × g (max. 12,000 rpm)‡ Up to 6 × 8-tube strips, 6 × 5-tube strips

or 48 × 0.2 mL PCR tubes‡ Safe and easy handling without additional lid

Fixed-angle rotor F-45-48-PCR

Ordering information for F-45-48-PCR: Page 31

16

Tube

Tube capacity (mL) 2.6–7 5 7–17 15 mL Falcon® 50 mL Falcon® 50 mL Centri prep® 50 mL Falcon® skirted

180–250 Eppendorf 400 mL bottle*4 (order no. 5810 729.009)

Eppendorf 500 mL bottle*4 (order no. 5820 707.003)

Max. tube length for all positionswith the aerosol-tight lid (mm)*1

107 108 118 119 116 – –

Max. tube length for all positions without the aerosol-tight lid (mm)*1

108 108 118 121 122 121 119 133

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 500 mL rectangular bucket

Adapter Requires use of MTP/Flex buckets for microplates, IsoRack adapter

Number of tubesper adapter/per rotor

25/100 18/72 16/64 12/48 5/20 5/20 1/4 1/4 1/4

Adapter bore (ø mm) 13 13 17.5 17.5 31 31 62 81 –

Adapter bottom shape fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical conical fl at with rubber mat fl at with rubber mat fl at, rubber –

Max. rcf (g-force) 3,000 3,000 3,000 3,100 3,100 3,100 3,100 3,220 3,250

Centrifugation radius (mm) 168 168 168 173 173 173 173 180 180

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000

Order no. (set of 2 adapters) 5810 720.001 5825 717.007 5810 721.008 5810 722.004 5810 723.000 5810 739.004 5825 722.000 5810 728.002 –

Adapters, lids and rotor are autoclavable: 20 min, 121 °C. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor. *2 Only Centriprep® tube without locking lid.

*3 Please note that these conical fl asks need to be used together with a conical form insert provided by the fl ask manufacturer.

*4 Available as a set of 2 fl asks (see ordering information).

Description A-4-81Swing-bucket rotor, with rectangular buckets, 4 × 500 mL

Replacement rectangular buckets,500 mL

Aerosol-tight lid,set of 2

set of 4

Max. rcf (× g) 3,250

Max. rotational speed (rpm) 4,000

Order no. 5810 718.007 5810 730.007 5810 724.007

Rotors exclusively for Centrifuges 5810 and 5810 R

Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifi cations subject to change.

17

*2 *3Tube

Tube capacity (mL) 2.6–7 5 7–17 15 mL Falcon® 50 mL Falcon® 50 mL Centri prep® 50 mL Falcon® skirted

180–250 Eppendorf 400 mL bottle*4 (order no. 5810 729.009)

Eppendorf 500 mL bottle*4 (order no. 5820 707.003)

Max. tube length for all positionswith the aerosol-tight lid (mm)*1

107 108 118 119 116 – –

Max. tube length for all positions without the aerosol-tight lid (mm)*1

108 108 118 121 122 121 119 133

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 500 mL rectangular bucket

Adapter Requires use of MTP/Flex buckets for microplates, IsoRack adapter

Number of tubesper adapter/per rotor

25/100 18/72 16/64 12/48 5/20 5/20 1/4 1/4 1/4

Adapter bore (ø mm) 13 13 17.5 17.5 31 31 62 81 –

Adapter bottom shape fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical conical fl at with rubber mat fl at with rubber mat fl at, rubber –

Max. rcf (g-force) 3,000 3,000 3,000 3,100 3,100 3,100 3,100 3,220 3,250

Centrifugation radius (mm) 168 168 168 173 173 173 173 180 180

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000

Order no. (set of 2 adapters) 5810 720.001 5825 717.007 5810 721.008 5810 722.004 5810 723.000 5810 739.004 5825 722.000 5810 728.002 –

Adapters, lids and rotor are autoclavable: 20 min, 121 °C. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor. *2 Only Centriprep® tube without locking lid.

*3 Please note that these conical fl asks need to be used together with a conical form insert provided by the fl ask manufacturer.

*4 Available as a set of 2 fl asks (see ordering information).

Rotors exclusively for Centrifuges 5810 and 5810 R

18Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifi cations subject to change.

Rotors exclusively for Centrifuges 5810 and 5810 R

Description A-4-62Swing-bucket rotor, with rectangular buckets, 4 × 250 mL

Replacement rectangular buckets,250 mL

Aerosol-tight lid,set of 2

set of 4

Max. rcf (× g) 3,200

Max. rotational speed (rpm) 4,000

Order no. 5810 709.008 5810 716.004 5810 710.006

Tube

Tube capacity (mL) 1.2–5 1.5–2 2.6–7 3–15 7–17 15 mL Falcon®

7–18 18–30 50 mL Falcon®

50 mL Falcon®

30–50 50 mL Falcon® skirted

50–75 80–120 180–250

Max. tube length for all positionswith the aerosol-tight lid (mm)*1

115 43 118 116 114 121 119 116 116 – 113 – 118 125 127

Max. tube length for all positions without the aerosol-tight lid (mm)*1

123 43 121 121 118 127 126 119 122 122 115 119 122 138 136

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 250 mL rectangular bucket

Adapter

Number of tubesper adapter/per rotor

25/100 16/64 15/60 12/48 12/48 9/36 8/32 4/16 3/12 4/16 4/16 2/8 1/4 1/4

Adapter bore (ø mm) 11 11 13 16 17.5 17.5 20 26 31 31 31 35 45 62

Adapter bottom shape fl at with rubber mat

fl at fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical fl at with rubber mat

fl at with rubber mat

conical fl at w. conical form insert

fl at with rubber mat fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

Max. rcf (g-force) 3,050 3,000 3,050 3,050 3,050 3,150 3,050 3,050 3,150 3,050 3,050 3,050 3,050 3,200

Centrifugation radius (mm) 173 171 173 173 173 178 173 173 178 173 173 173 173 180

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000

Order no. (set of 2 adapters) 5810 750.008 5810 751.004 5810 752.000 5810 753.007 5810 754.003 5810 755.000 5810 756.006 5810 757.002 5810 758.009 5810 763.002 5810 759.005 5810 760.003 5810 761.000 5810 770.009

Adapters, lids and rotor are autoclavable: 20 min, 121 °C. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor.

*2 When using 50 mL Falcon® tubes in the adapter 5810 763.002, the aerosol-tight lid can no longer be closed.

*3 Please note that these conical fl asks need to be used together with a conical form insert provided by the fl ask manufacturer.

*4 For high g-forces we recommend using centrifuge tubes of Duran® glass.

*5 Reordering of 50 mL form inserts: 5804 728.009.

19

*2,5

*4 *3

Rotors exclusively for Centrifuges 5810 and 5810 R

Tube

Tube capacity (mL) 1.2–5 1.5–2 2.6–7 3–15 7–17 15 mL Falcon®

7–18 18–30 50 mL Falcon®

50 mL Falcon®

30–50 50 mL Falcon® skirted

50–75 80–120 180–250

Max. tube length for all positionswith the aerosol-tight lid (mm)*1

115 43 118 116 114 121 119 116 116 – 113 – 118 125 127

Max. tube length for all positions without the aerosol-tight lid (mm)*1

123 43 121 121 118 127 126 119 122 122 115 119 122 138 136

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 250 mL rectangular bucket

Adapter

Number of tubesper adapter/per rotor

25/100 16/64 15/60 12/48 12/48 9/36 8/32 4/16 3/12 4/16 4/16 2/8 1/4 1/4

Adapter bore (ø mm) 11 11 13 16 17.5 17.5 20 26 31 31 31 35 45 62

Adapter bottom shape fl at with rubber mat

fl at fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical fl at with rubber mat

fl at with rubber mat

conical fl at w. conical form insert

fl at with rubber mat fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

Max. rcf (g-force) 3,050 3,000 3,050 3,050 3,050 3,150 3,050 3,050 3,150 3,050 3,050 3,050 3,050 3,200

Centrifugation radius (mm) 173 171 173 173 173 178 173 173 178 173 173 173 173 180

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000

Order no. (set of 2 adapters) 5810 750.008 5810 751.004 5810 752.000 5810 753.007 5810 754.003 5810 755.000 5810 756.006 5810 757.002 5810 758.009 5810 763.002 5810 759.005 5810 760.003 5810 761.000 5810 770.009

Adapters, lids and rotor are autoclavable: 20 min, 121 °C. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor.

*2 When using 50 mL Falcon® tubes in the adapter 5810 763.002, the aerosol-tight lid can no longer be closed.

*3 Please note that these conical fl asks need to be used together with a conical form insert provided by the fl ask manufacturer.

*4 For high g-forces we recommend using centrifuge tubes of Duran® glass.

*5 Reordering of 50 mL form inserts: 5804 728.009.

20

*2

Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifi cations subject to change.

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Tube

Tube capacity (mL) 1.2–5 1.5–2 2.6–7 3–15 7–17 15 mL Falcon®

15 mL Falcon®

7–18 18–30 50 mL Falcon®

50 mL Falcon®

50 mL Falcon®

30–50 50 mL Falcon® skirted

50–75 80–100

Max. tube length for all positionswith aerosol-tight lid (mm)*1

102 43 106 106 106 – 121 104 100 – 119 – 108 108 100

Max. tube length for all positions without aerosol-tight lid (mm)*1

105 43 108 108 110 121 121 107 110 122 122 120 122 119 114

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 100 mL rectangular bucket

Adapter

Number of tubesper adapter/per rotor

14/56 12/48 9/36 7/28 6/24 4/16 2/8 4/16 2/8 1/4 1/4 –/8 1/4 1/4 1/4

Adapter bore (ø mm) 11 11 13 16 17.5 17.5 17.5 20 26 31 31 – 31 35 45

Adapter bottom shape fl at with rubber mat

fl at fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical conical fl at with rubber mat

fl at with rubber mat

conical conical fl at w. conical form insert

fl at w. rubber mat fl at with rubber mat

fl at with rubber mat

Max. rcf (g-force) 4,200 4,100 4,200 4,200 4,200 4,300 4,400 4,200 4,200 4,300 4,400 4,500 4,200 4,200 4,200

Centrifugation radius (mm) 150 148 150 150 150 155 157 150 150 155 157 161 150 150 150

Max. rotational speed (rpm) 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000

Order no. (set of 2 adapters) 5804 750.004 5804 751.000 5804 752.007 5804 753.003 5804 754.000 5804 755.006 5804 717.007 5804 756.002 5804 757.009 5804 758.005 5804 718.003 5804 706.005*6 5804 759.001 5804 760.000 5804 761.006

Adapters, lids and rotor are autoclavable at 121 °C, 20 min. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor.

*2 Tube may only be centrifuged without the locking lid.

*3 Reordering of 50 mL form inserts: 5804 728.009.

*4 Filled conical tubes may be used in the 50 mL Falcon® bucketswhen they do not exceed a cumulative maximum weight of 0.14 kg.

*5 For high g-forces we recommend using centrifuge tubes of Duran® glass.

*6 Set of 4 buckets.

Description A-4-44Swing-bucket rotor, with rectangular buckets, 4 × 100 mL

Replacement rectangular buckets,100 mL

Aerosol-tight lid,set of 2

set of 4

Max. rcf (× g) 4,400

Max. rotational speed (rpm) 5,000

Order no. 5804 709.004 5804 741.005 5804 712.005

21

*5*5 *5

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Tube

Tube capacity (mL) 1.2–5 1.5–2 2.6–7 3–15 7–17 15 mL Falcon®

15 mL Falcon®

7–18 18–30 50 mL Falcon®

50 mL Falcon®

50 mL Falcon®

30–50 50 mL Falcon® skirted

50–75 80–100

Max. tube length for all positionswith aerosol-tight lid (mm)*1

102 43 106 106 106 – 121 104 100 – 119 – 108 108 100

Max. tube length for all positions without aerosol-tight lid (mm)*1

105 43 108 108 110 121 121 107 110 122 122 120 122 119 114

Adapter for 50 mL Falcon® skirted

Adapter

Order no. (set of 8 adapters) 5804 737.008

Adapter for 100 mL rectangular bucket

Adapter

Number of tubesper adapter/per rotor

14/56 12/48 9/36 7/28 6/24 4/16 2/8 4/16 2/8 1/4 1/4 –/8 1/4 1/4 1/4

Adapter bore (ø mm) 11 11 13 16 17.5 17.5 17.5 20 26 31 31 – 31 35 45

Adapter bottom shape fl at with rubber mat

fl at fl at with rubber mat

fl at with rubber mat

fl at with rubber mat

conical conical fl at with rubber mat

fl at with rubber mat

conical conical fl at w. conical form insert

fl at w. rubber mat fl at with rubber mat

fl at with rubber mat

Max. rcf (g-force) 4,200 4,100 4,200 4,200 4,200 4,300 4,400 4,200 4,200 4,300 4,400 4,500 4,200 4,200 4,200

Centrifugation radius (mm) 150 148 150 150 150 155 157 150 150 155 157 161 150 150 150

Max. rotational speed (rpm) 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000

Order no. (set of 2 adapters) 5804 750.004 5804 751.000 5804 752.007 5804 753.003 5804 754.000 5804 755.006 5804 717.007 5804 756.002 5804 757.009 5804 758.005 5804 718.003 5804 706.005*6 5804 759.001 5804 760.000 5804 761.006

Adapters, lids and rotor are autoclavable at 121 °C, 20 min. *1 Exceeding the maximum tube length may reduce the loading capacity of the rotor.

*2 Tube may only be centrifuged without the locking lid.

*3 Reordering of 50 mL form inserts: 5804 728.009.

*4 Filled conical tubes may be used in the 50 mL Falcon® bucketswhen they do not exceed a cumulative maximum weight of 0.14 kg.

*5 For high g-forces we recommend using centrifuge tubes of Duran® glass.

*6 Set of 4 buckets.

buckets*3, 4

22

Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifications subject to change.

Rotors exclusively for Centrifuges 5810 and 5810 R

Adapter

Description Adapter for IsoRack 0.5 mL tubes

Adapter for IsoRack 1.5/2.0 mL tubes

Adapter for MTP/Flex buckets for use with IsoRacks and cell culture flasks

Tubes per adapter/rotor 24/96 24/96

Max. rcf (g-force) 2,700 2,600

Centrifugation radius (mm) 150 146

Max. rotational speed (rpm) 4,000 4,000

Order no. (set of 2 adapters) 5825 708.008 5825 709.004

Buckets and rotor are autoclavable at 121 °C for 20 min.

Test plates

Type MTP Cell culture DWP Kits

Number per bucket/per rotor 4/16 2/8 1/4 1/4

Max. rcf (g-force) 2,900 2,900 2,900 2,900

Centrifugation radius (mm) 163 163 163 163

Dimensions L × W × H (mm) 128 × 85.6 × 15 128 × 85.6 × 21 128 × 85.6 × 45 128 × 85.6 × 60

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000

Description A-4-81-MTP/Flex Swing-bucket rotor, with 4 MTP/Flex buckets

MTP/Flex bucket

set of 4 set of 2

Max. rcf (× g) 2,900

Max. rotational speed (rpm) 4,000

Order no. 5810 725.003 5810 741.009 5810 742.005

23

Description A-4-62-MTP Swing-bucket rotor, with 4 MTP buckets

MTP buckets

set of 4

Max. rcf (× g) 2,750

Max. rotational speed (rpm) 4,000

Order no. 5810 711.002 5810 702.003

Test plates

Type MTP Cell culture DWP

Number per bucket/per rotor 3/12 2/8 1/4

Max. rcf (g-force) 2,750 2,750 2,750

Centrifugation radius (mm) 154 154 154

Dimensions L × W × H (mm) 128 × 85.6 × 15 128 × 85.6 × 21 128 × 85.6 × 45

Max. rotational speed (rpm) 4,000 4,000 4,000

Buckets and rotor are autoclavable at 121 °C for 20 minutes.

Rotors exclusively for Centrifuges 5810 and 5810 R

24

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Description A-2-DWP Deepwell plate rotor, with 2 buckets

Deepwell plate buckets

set of 2

Max. rcf (× g) 2,250

Max. rotational speed (rpm) 3,700

Order no. 5804 740.009 5804 743.008

Test plates

Type MTP Cell culture DWP Kits

Number per bucket/per rotor 5/10 4/8 2/4 1/2

Max. rcf (g-force) 2,250 2,250 2,250 2,250

Centrifugation radius (mm) 147 147 147 147

Dimensions L × W × H (mm) 128 × 85.6 × 15 128 × 85.6 × 21 128 × 85.6 × 45 128 × 85.6 × 89

Max. rotational speed (rpm) 4,000 4,000 4,000 4,000

Bucket and rotor are autoclavable at 121 °C, 20 min.

Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifications subject to change.

25

Rotor accessories for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Description MTP/Flex bucketfor rotor A-4-81-MTP/Flexset of 4

MTP bucketfor rotor A-4-62-MTPset of 4

Deepwell plate bucketfor rotor A-2-DWPset of 2

Order no. 5810 741.009 5810 702.003 5804 743.008

Adapter

Description Adapter for 384-well PCR plates

Adapter for 96-well PCR plates

CombiSlide® Adapter*1

CombiSlide® Adapter*1

Adapter for all Microplate/Deepwell plate rotor buckets

Tubes/glass slides per adapter/rotor

1/4*2 1/4*2 12/48*2 8/32*2

Max. rcf (g-force) 2,700*3 2,600*3 1,000*4 1,000*4

Centrifugation radius (mm) 150*3 146*3 150*3 150*3

Order no. (set of 2 adapters) 5825 713.001 5825 711.009 5825 706.005 5825 706.005

*1 The CombiSlide includes a fl exible component set that enables the use of glass slides across and parallel to the direction of centrifugation.

*2 With the A-2-DWP, only half of the plates/glass slides can be used per rotor.

*3 With the A-2-DWP, a slightly lower rcf of approx. 2,200 × g is reached at a max. rotational speed of 3,700 rpm and a reduced radius.

*4 The probability of glass breakage increases with an exertion greater than the allowed rcf of 100 × g. The limiting data from the manufacturer of the glass slides/microarrays with respect to endurance must be observed in each case. A test run with empty glass slides from the manufacturer is recommended.

26

Attention! Observe safety precautions and operating manual. Errors and omissions excepted; technical specifications subject to change.

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Description F-34-6-38 High-speed fixed-angle rotor, with screw-on lid, for 6 × 85 mL tubes

Replacement lid for fixed-angle rotor F-34-6-38

Max. rcf (× g) 15,550 /18,500 (in 5810 R)

Max. rotational speed (rpm) 11,000 / 12,000 (in 5810 R)

Order no. 5804 727.002 5804 727.509

Tube (Please observe the limits for the load-bearing capacity of the tubes as specified by the tube manufacturer)

Tube capacity (mL) 1.5–2 7–15 15 mL Falcon® 15–18 20–30 50 50 mL Falcon® 85*1

Max. tube length for all positions under the rotor lid (mm)

110 112 123 123 123 123 121 121

Adapter for 6 × 85 mL fixed-angle rotor

Adapter

no adapter needed

Number of tubes per adapter/per rotor

4/24 2/12 1/6 1/6 1/6 1/6 1/6 –/6

Adapter bore (ø mm) 11 16 17.5 18 26 29 29.5 38

Adapter bottom shape round round conical round round round conical –

Max. rcf (g-force) at 11,000 rpm (5804/ 5804 R/ 5810)

15,300 15,150 14,450 14,750 14,900 15,150 14,600 15,550

Max. rcf (g-force) at 12,000 rpm (5810 R)

18,200 18,000 17,200 17,550 17,700 18,000 17,400 18,500

Centrifugation radius (mm) 113 112 107 109 110 112 108 115

Max. rotational speed for 4 °C 11,000 11,000 11,000 11,000 11,000 11,000 11,000 11,000

Order no. (set of 2 adapters) 5804 770.005 5804 771.001 5804 776.003 5804 772.008 5804 773.004 5804 774.000 5804 775.007 –

Adapters, lid and rotor are autoclavable at 121 °C, 20 min. *1 Nominal volume.

27

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Tube (Please observe the limits for the load-bearing capacity of the tubes as specified by the tube manufacturer)

Tube capacity (mL) 1.5–2 7–15 15 mL Falcon® 15–18 20–30 50 50 mL Falcon® 85*1

Max. tube length for all positions under the rotor lid (mm)

110 112 123 123 123 123 121 121

Adapter for 6 × 85 mL fixed-angle rotor

Adapter

no adapter needed

Number of tubes per adapter/per rotor

4/24 2/12 1/6 1/6 1/6 1/6 1/6 –/6

Adapter bore (ø mm) 11 16 17.5 18 26 29 29.5 38

Adapter bottom shape round round conical round round round conical –

Max. rcf (g-force) at 11,000 rpm (5804/ 5804 R/ 5810)

15,300 15,150 14,450 14,750 14,900 15,150 14,600 15,550

Max. rcf (g-force) at 12,000 rpm (5810 R)

18,200 18,000 17,200 17,550 17,700 18,000 17,400 18,500

Centrifugation radius (mm) 113 112 107 109 110 112 108 115

Max. rotational speed for 4 °C 11,000 11,000 11,000 11,000 11,000 11,000 11,000 11,000

Order no. (set of 2 adapters) 5804 770.005 5804 771.001 5804 776.003 5804 772.008 5804 773.004 5804 774.000 5804 775.007 –

Adapters, lid and rotor are autoclavable at 121 °C, 20 min. *1 Nominal volume.

28Attention! Observe safety precautions and operating manual. Errors and omissions expected; technical specifi cations subject to change.

Description F-45-30-11 Fixed-angle rotor, with lid, for micro test tubes 30 × 1.5/2 mL

FA-45-30-11 Aerosol-tight fi xed-angle rotor, with lid*1,for micro test tubes 30 × 1.5/2 mL

Max. rcf (× g) 20,800 20,800

Max. rotational speed (rpm) 14,000 14,000

Order no. 5804 715.004 5804 726.006

Tube

(Please observe the limitsfor the load-bearing capacityof the tubes as specifi edby the tube manufacturer)

Tube capacity (mL) 1.5–2 0.2 0.4 0.5 0.6

Adapter for 30 × 1.5/2 mL fi xed-angle rotor

Adapter

no adapter needed

Number of tubes per adapter/per rotor –/30 1/30 1/30 1/30 1/30

Adapter bore (ø mm) – 6 6 8 8

Max. rcf (g-force) 20,800 16,200 20,800 18,400 20,800

Centrifugation radius (mm) 95 74 95 84 95

Max. rotational speed (rpm) 14,000 14,000 14,000 14,000 14,000

Order no. (set of 6 adapters) – 5425 715.005 5425 717.008 5425 716.001 5425 716.001

Adapters, lids and rotor are autoclavable at 121 °C, 20 min.

*1 Aerosol-tightness of lid tested by the Centre for Applied Microbiology & Research, Porton Down, CAMR, Great Britain.

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

29

Description F-45-48-PCR Fixed-angle rotor, for 6 × 5- and 8-tube strips or 48 × 0.2 mL PCR tubes

T-60-11 Drum rotor, 60 × 1.5/2 mL

Max. rcf (× g) 15,350 14,000

Max. rotational speed (rpm) 12,000 16,400

Order no. 5804 735.005 5804 730.003

Tube

Tube capacity (mL) 8-tube strips 0.2 0.4 1.5–2

Adapter

Number of tubes per adapter/per rotor

6 × 8-tube strip 48 20/120 10/60

Adapter bore (ø mm) 6 6 6 11

Max. rcf (g-force) 15,350 15,350 16,400 16,400

Max. rotational speed (rpm) 12,000 12,000 14,000 14,000

Order no. (set of 6 adapters) – – 5804 732.006 5804 731.000

Rotors for Centrifuges 5804 / 5804 R and 5810 / 5810 R

30

Ordering information for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Ordering information

Description Order no.

Rotor A-4-81

Swing-bucket rotor, with 4 × 500 mL rectangular buckets 5810 718.007Swing-bucket rotor, without buckets 5810 743.001

Accessories for A-4-81

Rectangular buckets 500 mL, 4 pieces 5810 730.007

Aerosol-tight lids, for 500 mL rectangular buckets, set of 2 5810 724.007

Wide-mouth flask, 400 mL, plastic, set of 2 5810 729.009

Wide-mouth flask, 500 mL, plastic, set of 2 5820 707.003

Spare rubber mat, 4 pieces 5810 734.002

Spare adapter clamp, 2 pieces 5810 735.009

Rotor A-4-81-MTP/Flex

Swing-bucket rotor, with 4 MTP/Flex buckets 5810 725.003

Accessories for A-4-81-MTP/Flex

MTP/Flex buckets4 pieces 5810 741.0092 pieces (for mixed loading) 5810 742.005IsoRack starter set for MTP/Flex buckets2 × IsoRack adapter, 2 × IsoRack with lid and 2 × cool packs (0 °C IsoPack) for 0.5 mL and 1.5/2 mL micro test tubes

5825 721.004

PCR plate adapterFor 96-well plates, set of 2 5825 711.009For 384-well plates, set of 2 5825 713.001CombiSlideSlide adapter, set of 2 5825 706.005

Rotor A-4-62

Swing-bucket rotor, with 4 × 250 mL rectangular buckets 5810 709.008

Accessories for A-4-62

Rectangular buckets 250 mL4 pieces 5810 716.004

Aerosol-tight lids, for 250 mL rectangular buckets, set of 2 5810 710.006

8 form inserts for 50 mL Falcon® tubes (conical) as a reorder 5804 728.009

Spare rubber mat, 4 pieces 5810 782.007

Spare adapter clamp, 2 pieces 5810 781.000

Rotor A-4-62-MTP

Swing-bucket rotor, with 4 MTP buckets 5810 711.002

Accessories for A-4-62-MTP

MTP-buckets4 pieces 5810 702.003PCR plate adapterFor 96-well plates, set of 2 5825 711.009For 384-well plates, set of 2 5825 713.001CombiSlideSlide adapter, set of 2 5825 706.005

Ordering information

Description Order no.

Centrifuges 5804, benchtop centrifuge, without rotor 5804 000.013Centrifuges 5804 R, benchtop centrifuge, without rotor, refrigerated 5805 000.017Centrifuges 5810, benchtop centrifuge, without rotor 5810 000.017Centrifuges 5810 R, benchtop centrifuge, without rotor, refrigerated 5811 000.010

31

Ordering information for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Ordering information

Description Order no.

Rotor A-4-44

Swing-bucket rotor, with 4 × 100 mL rectangular buckets 5804 709.004Swing-bucket rotor, with 4 Falcon® buckets 5804 719.000

Accessories for A-4-44

Rectangular buckets 100 mL, 4 pieces 5804 741.005

Aerosol-tight lids, for 100 mL rectangular buckets, set of 2 5804 712.005

4 Falcon® buckets, each for 2 × 50 mL Falcon® tubes for swing-bucket rotor A-4-44 incl. form inserts 5804 706.005

8 form inserts for 50 mL Falcon® tubes (conical) as a reorder 5804 728.009

Spare rubber mat, 4 pieces 5804 782.003

Spare adapter clamp, 2 pieces 5804 781.007

Rotor A-2-DWP

Deepwell plate rotor, with 2 buckets 5804 740.009

Accessories for A-2-DWP

Deepwell plate buckets2 pieces 5804 743.008

Rotor F-34-6-38

Fixed-angle rotor 6 × 85 mL, with lid 5804 727.002

Rotor FA-45-30-11

Fixed-angle rotor 30 × 1.5/2 mL, with aluminium lid, aerosol-tight*1 5804 726.006

Rotor F-45-30-11

Fixed-angle rotor 30 × 1.5/2 mL, with aluminium lid 5804 715.004

Adapters for rotor FA-45-30-11 and F-45-30-11

Adapter for 0.2 mL PCR tubes, set of 6 5425 715.005Adapter for 0.4 mL tubes, set of 6 5425 717.008Adapter for 0.5 mL tubes and 0.6 mL Microtainer®, set of 6 5425 716.001

Rotor F-45-48-PCR

Fixed-angle rotor for 6 × 8-tube, 6 × 5-tube strips or 48 × 0.2 mL PCR tubes 5804 735.005

Rotor T-60-11

Drum rotor, with lid, for use with 6 adapters 5804 730.003

*1 Aerosol-tightness of lid tested by the Centre for Applied Microbiology & Research, Porton Down, CAMR, Great Britain.

*1 Eppendorf centrifuges serve to separate components of mixtures of different densities, especially for the preparation and processing of samples from the human body within the scope of In-vitro diagnostics applications, in order to allow the In-vitro diagnostic medical device to be used as intended. Therefore centrifuges,

being in-vitro diagnostics accessories, are in themselves In-vitro diagnostic medical devices within the meaning of Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 in-vitro diagnostic medical devices. Eppendorf centrifuges are intended exclusively for use indoors, and for operation by qualified staff.

Description Centrifuge 5804 Centrifuge 5804 R Centrifuge 5810 Centrifuge 5810 R

Maximum rcf• Fixed-angle rotor• Swing-bucket rotor• Plate rotor

20,800 × g 4,500 × g 2,250 × g

20,800 × g 4,500 × g 2,250 × g

20,800 × g 4,500 × g 2,900 × g

20,800 × g 4,500 × g 2,900 × g

Speed 200–14,000 rpm (in 10 rpm increments)

Maximum capacity 4 × 100 mL, 6 × 85 mL 4 × 100 mL, 6 × 85 mL 4 × 500 mL 4 × 500 mL

Rotor options 7 7 11 11

Accel./Braking ramps 10/10

Programs 35 user programs

Timer 30 s to 99 min, with continuous mode, short spin

Temperature control range N/A –9 °C to 40 °C N/A –9 °C to 40 °C

Noise level

Rotor A-4-81 (4 × 400 mL) <65 dB(A) <56 dB(A)

Rotor A-4-44 (4 × 100 mL) <67 dB(A) <56 dB(A) <65 dB(A) <56 dB(A)

Rotor F-34-6-38 (6 × 85 mL) <51 dB(A) <58 dB(A) <53 dB(A) <59 dB(A)

Power suppy 230 V/50–60 Hz 230 V/50–60 Hz 230 V/50–60 Hz 230 V/50–60 Hz

Power requirement Max. 900 W Max. 1,650 W Max. 900 W Max. 1,650 W

Dimensions (W × D × H) 47 × 55 × 34 cm 64 × 55 × 34 cm 54 × 61 × 35 cm 70 × 61 × 35 cm

Weight without rotor 55 kg 80 kg 68 kg 99 kg

Register your Eppendorf products online now to benefit fromnumerous advantages! You receive bonus ep-points immediatelyfor each Eppendorf device registered. You can also easily manageyour devices online and are always kept up-to-date on any news.

www.eppendorf.com/myeppendorf

Cen

trip

rep®

is a

regi

ster

ed tr

adem

ark

of M

illip

ore

Cor

pora

tion.

Dur

an® is

a re

gist

ered

trad

emar

k of

Sch

ott A

G. F

alco

n® a

nd M

icro

tain

er® a

re re

gist

ered

trad

emar

ks o

f Bec

ton

Dic

kins

on.

eppe

ndor

f® a

nd C

ombi

Slid

e® a

re re

gist

ered

trad

emar

ks o

f Epp

endo

rf A

G. A

ll rig

hts

rese

rved

, inc

ludi

ng g

raph

ics

and

imag

es. C

opyr

ight

© 2

010

by E

ppen

dorf

AG

Ord

er n

o. A

58X

X12

020

/GB

3/3T

/101

0/FE

EL/

Prin

t64

· Prin

ted

in G

erm

any

Your local distributor: www.eppendorf.com/worldwideEppendorf AG · 22331 Hamburg · Germany · Tel: +49 40 538 01-0 · Fax: +49 40 538 01-556 · E-mail: [email protected]

Eppendorf North America, Inc. · 102 Motor Parkway, Suite 410 · Hauppauge, N.Y. 11788-5178 · USA · Tel: +1 516 334 7500Toll free phone: +1 800 645 3050 · Fax: +1 516 334 7506 · E-mail: [email protected]

Application Support Europe, International: Tel: +49 1803 666 789 · E-mail: [email protected] America: Tel: +1 800 645 3050 menu option 2 · E-mail: [email protected]

Asia Pacifi c: Tel: +60 3 8023 6869 · E-mail: support_asiapacifi [email protected]

Technical specifi cations for Centrifuges 5804 / 5804 R and 5810 / 5810 R

Eppendorf Multipurpose Centrifuges 5804 / 5804 R and 5810 / 5810 R