Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any...

7
Alarm Mon-itorin t Texecom Alarm Systems The following panels have been integrated to the WebWay signalling solution Texecom 60, 88, 168, 816, 412, 832 Elite 48 For 60, 88,168, 816 (wwo) integrations are via a TTL link to com port 1 on the Texecom panel WebWayOne cable 05-0246 is required for installation 412,816 (Std),832 are via a webway modem capture module (22-5059) For Wintex programming via a PC a USB Com cable (Texecom part no JAA-0001 or JAC-0001 Texecom Series WebWay Alarm Panel Integration WebWayOne Alarm System integration improves security and reduces costs WebWayOne and Texecom have integrated the WebWay IP/GPRS and WebWay GPRS/PSTN to provide Insurance Class Alarm signalling including the six essential elements of a fully managed Alarm System. Simple installation and commissioning The WebWay solution is quick and easy to install and commission with your chosen ARC. A cable to the Alarm System, a two-wire connection for power, an Ethernet cable to the Router and locate the aerial. Our Auto Take On process completes the WebWay installation. The WebWay servers automatically programme the WebWay to work seamlessly with the Texecom to enable SIA alarms, Upload Download and secure remote access using the Texecom Wintex software. Automatic Commissioning ATS Monitoring and Fault Reporting Alarm and Fault reporting Remote Support Upload/Download Remote Maintenance www.webwayone.co.uk [email protected] 01635 231500 Serial Panel Connection Connect the 05-0246 connector cable to the Texecom onto Com Port 1. Com port 2 usually has a local PC or other peripheral equipment connected. Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. WebWay SPT Texecom T - Red Com Port 1 R - Green RTN - Blue 1 Automatic SIA 3 with text enriched messages All alarms generated by the Alarm System are automatically sent to the AMS using SIA. SIA messages provide a full audit trail of an event - which detector, location, time and date, and a permanent record of every alarm. Messages for set and unset include who, where, time, and date, all recorded. No need to check that each PIN is correctly wired; the Texecom and the WebWay take care of everything automatically.

Transcript of Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any...

Page 1: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Alarm Mon-itorin t

Texecom Alarm Systems

The following panels have been integrated to the WebWay signalling solution Texecom 60, 88, 168, 816, 412, 832 Elite 48

For 60, 88,168, 816 (wwo) integrations are via a TTL link to com

port 1 on the Texecom panel

WebWayOne cable 05-0246 is required for installation

412,816 (Std),832 are via a webway modem capture module (22-5059)

For Wintex programming via a PC a USB Com cable (Texecom

part no JAA-0001 or JAC-0001

Texecom Series WebWay Alarm Panel Integration

WebWayOne Alarm System integration improves security

and reduces costs

WebWayOne and Texecom have integrated the WebWay IP/GPRS and

WebWay GPRS/PSTN to provide Insurance Class Alarm signalling

including the six essential elements of a fully managed Alarm System.

Simple installation and commissioning

The WebWay solution is quick and easy to install and commission with

your chosen ARC. A cable to the Alarm System, a two-wire connection

for power, an Ethernet cable to the Router and locate the aerial.

Our Auto Take On process completes the WebWay installation. The

WebWay servers automatically programme the WebWay to work

seamlessly with the Texecom to enable SIA alarms, Upload Download

and secure remote access using the Texecom Wintex software.

WebWayOne

Signalling

Automatic Commissioning ATS Monitoring and Fault Reporting Alarm and Fault reporting Remote Support Upload/Download Remote Maintenance

www.webwayone.co.uk

[email protected]

01635 231500

Serial Panel Connection

Connect the 05-0246 connector cable to the Texecom onto Com Port 1.

Com port 2 usually has a local PC or other peripheral equipment

connected.

Texecom TTL Cable 05-0246

Connect the WebWay PWR + and - to any relevant Power (+12V/+24V)

and Ground (0V) terminals.

WebWay SPT Texecom

T - Red

Com Port 1 R - Green

RTN - Blue

1

Automatic SIA 3 with text enriched messages All alarms generated by the Alarm System are automatically sent to the AMS using SIA. SIA messages provide a full audit trail of an event - which detector, location, time and date, and a permanent record of every alarm. Messages for set and unset include who, where, time, and date, all recorded. No need to check that each PIN is correctly wired; the Texecom and the WebWay take care of everything automatically.

Page 2: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Wintex Settings

Important: The WebWay SPT should be connected to Com port 1.

All settings are configured with the Wintex Communications menu (7th option down on the left side of the Wintex program labeled Comms). This can

be configured on a local PC plugged on to Com Port 2 with the WebWay unit running on Com Port 1. (In keypad settings leave Com Port 2 as

unassigned, when the PC cable is connected it will automatically detect and allow you to configure settings).

Texecom 88/168/60 Series

The Texecom panel configuration is uploaded via the Wintex software and downloaded to the panel on com port 2 from a local PC. The following

requires configuring in the panel,

Communications Menu

In Options

1. Enable communicator must be ticked

2. UDL passcode (set in the panel) must match.

3. Dial attempts 1, ring before answer 3

Important: The WebWay should be connected to Com port 1.

All other settings are done by the Wintex Communications menu (7th option down on the left side of the Wintex program labeled Comms). This can be

configured on a local PC plugged on to Com Port 2 with the WebWay unit running on Com Port 1.

2

In Radio-Pad and Com Port options

1. Com Port 1 – WebWayOne module

2. Local IP address 127.0.0.1

3. Local IP port 50561

4. Gateway 127.0.0.1

5. Subnet Mask 255.255.255.0

6. Name/SMG port 50561

In ARC’s

1. Account number (site ID)

2. SIA Level 2/3

3. Connect Via IP - ticked

4. Send SIA text – ticked

www.webwayone.co.uk

[email protected]

01635 231500

Texecom Series

Page 3: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Texecom Series

“Account No:” should match the ARC Site/Chip ID and tick the relevant trigger event boxes relevant to the premises.

If the SMS call centre is utilised the engineer should enter the appropriate number and it should be configured under:

UDL/Digi Options – Radio/SMS Option – SMS Centre Pri.

The SMS centre telephone number is used to send SMS text messages to mobile phones. (Default = 07860980480).

Note if the Texecom is being programmed with a laptop on com port 2, and the WebWay is connected to com port 1 the SPT will be lost from the

panel until the Wintex session is closed.

www.webwayone.co.uk

[email protected]

01635 231500

3

Texecom 88/168/60

Series

Page 4: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Texecom Series

Texecom Premier 816 (WWO Version)

Panel configuration

Enter Programming Options

Menu 70: Communicator Options

1: Enable Communicator ENABLED

2: Enable DTMF Dialing DISABLED

3: Pulse after 3rd attempt DISABLED

4: European Pulse Dialing DISABLED

5: Enable Test Transmission OPTIONAL

6: Enable Cancel Call Waiting DISABLED

7: Enable Backup to ARC DISABLED

8: Enable Blind Dialing DISABLED

Menu 71: ARC 1 Menu

0: Phone number Leave blank

1: Account number Site Chip Number

2: Protocol SIA Level 2/3

3: Dial Attempts 9

4: Partition Options 1234 (optional)

5: Reporting Options 12345678 (optional)

8: Protocol Options * * * * * * * 8 – Connect Via IP

WebWay SPT Texecom

T - Red

Com Port 1 R - Green

RTN - Blue

A special version of the 816 known as the “Premier 816 WWO” is

shipped with special software which allows it to communicate with the

2424 SPT, however it does not have a dialer which means that it can

only be used with the 2424 system.

Note that a cable assembly is required , which WebWayOne can supply

although any 5-Way Molex type connecter can be modified.

The Texecom main board assembly has only 1 Com port on the PCB

with a 5-pin connection interface. This connects to the TTL R, T and

gnd terminals of the WebWayOne 2424 panel interface. This means

that a local PC and the 2424 SPT cannot be connected to the panel at

the same time. When connecting the local PC, leave the SPT

disconnected for about 30 seconds before connecting to the PC. This

should ensure that the panel recognizes that the SPT has been

disconnected.

If there are problems establishing communications with the local PC,

try entering user code + menu + 7 on the panel keypad (abort all

communications).

The connection details are as follows:

4

www.webwayone.co.uk

[email protected]

01635 231500

Menu 76: Download Menu

5: Com1 equipment type 003 - ComIP Module

6: Com IP-address & port 12700000000150562

Enter full octet (***.***.***.***) with no periods. Port should always be

50561

Example, IP 192.168.0.101 Port 50561: Enter as 19216800010150561

Note that 127.0.0.1 is interpreted by the SPT as ’use DHCP’.

7: LAN gateway IP (the local router) 127000000001

Enter full octet (***.***.***.***) with no periods.

Example, IP 192.168.0.1: enter as 192168000001

Note that 127.0.0.1 is interpreted by the SPT as ’use DHCP’.

8: Netmask 8 (255.255.255.0)

This is selected from a list (see the Premier manual for full details).

DHCP settings for IP & LAN gateway will override this setting.

9: IP & port for main MCT

Enter full octet (***.***.***.***) with no periods. Port should always be

50561.

Example, IP 85.200.242.12 Port 50561: Enter as 08520024201250561

Configuration can also be done via the Wintex program

Page 5: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Texecom Series

Texecom 412,816 (Standard Edition),832

The following models are integrated via a modem capture module, provided by WebWay. This type of integration does not support Upload/Download functionality. The modem capture board needs wiring as follows to the Texecom panel.

WebWay Modem Capture Texecom

A T

B R

5

Panel configuration

Enter Programming Options

Menu 70: Communicator Options

1: Enable Communicator ENABLED

2: Enable DTMF Dialing ENABLED

3: Pulse after 3rd attempt DISABLED

4: European Pulse Dialing DISABLED

5: Enable Test Transmission OPTIONAL

6: Enable Cancel Call Waiting DISABLED

7: Enable Backup to ARC DISABLED

8: Enable Blind Dialing ENABLED

Menu 71: ARC 1 Menu

0: Phone number 01635 231514

1: Account number Partiton 1Site Chip Number

(Ensure reporting for partition(s) is enabled)

2: Protocol SIA Level 2/3

3: Dial Attempts 9

4: Partition Options 1234 (optional)

5: Reporting Options 12345678 (optional)

8: Protocol Options All blank

www.webwayone.co.uk

[email protected]

01635 231500

Panel configuration can also be completed with Texecoms wintex program.

In the comms menu set the following in Options;

In the comms menu set the following in ARCs;

Page 6: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Texecom Series Texecom Elite 48

Requirements for the Texecom Elite 48:

For Wintex access via a PC or remote manager version 6

Build 2

For Wintex programming via a PC a USB Com cable

(Texecom part no JAA-0001 or JAC-0001

Texecom TTL Cable 05-0246

Connect to the Texecom Panel is as follows,

Wintex Programming

Simple Configuration can be achieved with Texecoms Wintex program

and a suitable comms cable. To allow communications simply connect

the cables to com port two on the device and then Config a account as

usual with the following settings in comms.

(In keypad settings leave Com Port 2 as unassigned, when the PC

cable is connected it will automatically detect and allow you to

configure settings).

In options

Enable Communicator must be ticked

WebWay SPT Texecom

T - Red

Com Port 1 R - Green

RTN - Blue

If Upload/Download is needed ensure the settings below are configured

In ARCs ensure that,

Account no matches the Chip ID for the site Protocol in SIA Level 2/3 is selected User Area accounts is ticked Connect Via IP is ticked Send SIA text is ticked

Ensure any reporting settings are set as required

www.webwayone.co.uk

[email protected]

01635 231500

6

Page 7: Texecom Series - WebWay World · Texecom TTL Cable 05-0246 Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Texecom T - Red R - Green Com

Texecom Series Texecom Elite 48

Radio Pad and Com port settings

Ensure Com Port 1 is set to WebWayOne/Emizon Module

Finally Send the update back to the panel.

To set up via keypad

Enter Engineer password Press Menu Scroll to UDL/Digi Options (7) Select Digi Options Ensure the first option is set to E***** (Enable Communicator) Select UDL Options Scroll to UDL password is Set this to match the Texecom Wintex Application UDL Password (Default 1234) In Area Accounts set the Area ids to match the site Chip Number Select Program Digi Set Arc 1 Protocol to SIA level II Primary and Secondary Number are blank Set Account Number as the Chip number Dialling Attempts as 2 Reporting Areas as required Reports as required Set config as A*****IT

A –Use Area Accounts I – Connect via IP T- Send SIA Text

In com port Options select Com Port 1, set this to Emizon/WebWayOne

www.webwayone.co.uk

[email protected]

01635 231500

7

Texecom48 Elite