Page 1: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

TECHNICAL INSTALLATIONINSTRUCTIONS

Page 2: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

• All products must be inspected before installation. MICO Distribution is not liable for installation costs.

• Before installing, ALWAYS read the accompanying installation notes.

• Any wall to which a product is fixed must be of suitable construction to support that product’s weight.

• To assist with future maintenance, it is strongly recommended that furniture and ceramics be fitted to a tiled surface (rather than butting tiles against an item).

• The glaze used on MICO Distribution’s ceramic products is tough and non-porous. However, it must not be put under undue stress which may cause crazing or other damage:

~ Do not over-tighten the waste – hand tighten only with the correct sealant and contoured waste ~ Do not over-tighten tapware during installation ~ Water temperature should not exceed 55ºC ~ Do not drop anything onto a glazed surface

• To avoid damage, tapware and showers MUST have the appropriate inline filters, and water pressure should not be no more than 500kPA.

• To avoid deterioration, it is important mirrors are kept dry of any moisture, especially along edges. (Refer to instructions for the appropriate cleaning method.)

• Cleaning products are to be used as per instructions. Use a moist soft cloth, micro fibre cloth or a diluted mild detergent. Never use products containing acids, bleach or caustic soda. Never use cleaners of a gritty, abrasive nature.

• Ceramic products are fired in a kiln, then cooled – a process which causes shrinking. Therefore, items may not be perfectly square or flat. Each product is checked to ensure it meets strict tolerances before dispatch.

Installation Notes

• Unless stated, all MICO Distribution products carry a five year warranty which covers manufacturing faults. However, MICO Distribution are not liable for any consequent loss or damage resulting from any failure.

• Shower hoses, cartridges, mirrors, cistern fittings, toilet seats, electrical and shower seals have a one year warranty.

• Inwall cisterns have a fifteen year warranty. Easily replaced cistern fittings (face plate; washers, valves etc) have a one year warranty.

• The warranty does not cover misuse, incorrect installation, neglect, modification, wilful damage, flooding, inappropriate cleaning methods, accidental damage and/or other events outside our control.

• Proof of purchase must be provided to claim any warranty.

• MICO Distribution shall not be liable for any labour, materials or any other costs should the wrong product be installed or if there are any noticeable defects resulting from installation.

• For full terms and conditions please visit www.mico.co.nz or ask for a copy to be supplied.

WARRANTY

INSTALLATION & WARRANTY

Page 3: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

1

ATLANTA TECHNICAL DRAWINGSWALL HUNG UNITS

750mm 495mm

530m

m

700mm 335mm

327m

m865mm 500mm

530m

m

800mm 335mm

1200mm 500mm

530m

m

1150mm 335mm

750mm 495mm

840m

m

700mm 335mm

492m

m

750mm Two door

860mmTwo doorTwo Drawer

1200mmTwo Door Two Drawer

ATLANTA TECHNICAL DRAWINGSFLOOR STANDING UNITS

750mm Two door

For all internal draw measurements see page 11.

For all internal draw measurements see page 11.

NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

Page 4: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

ATLANTA TECHNICAL DRAWINGS

2

865mm 500mm

840m

m

800mm 335mm

492m

m

163m

m16

3mm

163m

m1200mm 500mm

840m

m

1150mm 335mm

492m

m

163m

m16

3mm

163m

m

FLOOR STANDING UNITS - Continued

860mmTwo doorTwo Drawer

1200mmTwo Door Two Drawer

CAMBRIDGE TECHNICAL DRAWINGS

450

+3 0750 +3

0

250

97

53

�35±1

50

120±

3

20±2

R8

R3

143±

3

13

500

750mm 450mm

472m

m

322m

m

WALL HUNG UNITS

750mm One Drawer

450

+3 0

750 +3 0

250

97

53

�35±1

50

120±

3

20±2

R8

R3

143±

3

13

500

750mm Two Drawer

750mm 450mm

472m

m

222m

m22

2mm

450

+3 0

750 +3 0

250

97

53

�35±1

50

120±

3

20±2

R8

R3

143±

3

13

500

450

+3 0

750 +3 0

250

97

53

�35±1

50

120±

3

20±2

R8

R3

143±

3

13

500

For all internal draw measurements see page 11.

For all internal draw measurements see page 11.

Page 5: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

3

CAMBRIDGE TECHNICAL DRAWINGSWALL HUNG UNITS - Continued

900mm One Drawer

900mm 450mm

472m

m

322m

m

900mm 450mm

472m

m 222m

m22

2mm

900mm Two Drawer

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

1200mm One Drawer

1200mm Two Drawer

1200mm 450mm

472m

m

322m

m

450

+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500

450

+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500

1200mm 450mm

472m

m

222m

m22

2mm

450

+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500

450

+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500CAMBRIDGE TECHNICAL DRAWINGSFLOOR STANDING UNITS

750mm Two door

750mm 450mm

822m

m 261m

m26

1mm

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

For all internal draw measurements see page 11.

For all internal draw measurements see page 11.

Page 6: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

4NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

CAMBRIDGE TECHNICAL DRAWINGSFLOOR STANDING UNITS - Continued

900mm Two Drawer

1200mm Two Drawer

900mm 450mm

822m

m 261m

m26

1mm

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

450

+3 0

900 +4 0

250

9753

�35±1

50

120±

2

20±2

R8R3

143±

3

13

500

1200mm 450mm

822m

m 261m

m26

1mm 45

0+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500

450

+3 0

1200 +4 0

250

9753

�35±1

50

120±

3

20±2

R8

R3

143±

3

13.5

500

BOSTON TECHNICAL DRAWINGSWALL HUNG UNITS

750mm One door

750mm 462mm

470m

m

448m

m

750

460

�38

230

�50

120

65

440

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-001-A

2010.12.13

JL

NONE

750x460x180mm basin

EP ISSUE EP-9075E 2010.12.13

900mm One door

900

460

�3855

230

�50

120

65

470

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-002-A

2010.12.13

JL

NONE

900x460x180mm basin

EP ISSUE EP-9090E 2010.12.13

900mm 467mm

470m

m

448m

m

For all internal draw measurements see page 11.

For all internal draw measurements see page 11.

Page 7: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

5

BOSTON TECHNICAL DRAWINGSWALL HUNG UNITS - Continued

1200mm One Drawer

900mm Two DoorOne Drawer

1200mm Two DoorTwo Drawer

1200mm Two Drawer Side by SideDouble Bowl

BOSTON TECHNICAL DRAWINGSFloor Standing UNITS

900mm 467mm

470m

m

448m

m

1200mm 466mm

470m

m

448m

m

1200mm 467mm

470m

m

448m

m

1200mm 475mm

470m

m

448m

m

900

460

�3855

230

�50

120

65

470

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-002-A

2010.12.13

JL

NONE

900x460x180mm basin

EP ISSUE EP-9090E 2010.12.13

1200

460

�385523

0

�50

120

65

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

1200

460

�385523

0�50

120

65

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

1200

460

�385523

0

�5012

065

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

750mm Two Drawer

750mm 468mm

820m

m

261m

m26

1mm

750

460

�38

230

�50

120

65

440

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-001-A

2010.12.13

JL

NONE

750x460x180mm basin

EP ISSUE EP-9075E 2010.12.13

For all internal draw measurements see page 11.

For all internal draw measurements see page 11.

Page 8: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

6

BOSTON TECHNICAL DRAWINGSFLOOR STANDING UNITS - Continued

900mm Two Drawer

1200mm Two Drawer

1200mm Two Drawer Double Bowl

900mm 467mm

820m

m

261m

m26

1mm

1200mm 466mm

820m

m

261m

m26

1mm

1200mm 466mm

820m

m

261m

m26

1mm

1200

460

�385523

0

�50

120

65

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

1200

460

�385523

0

�50

120

65

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

900

460

�3855

230

�50

120

65

470

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-002-A

2010.12.13

JL

NONE

900x460x180mm basin

EP ISSUE EP-9090E 2010.12.13

750mm One DoorTwo Drawers

900mm Two DoorTwo Drawers

750mm 468mm

322m

m32

2mm

820m

m64

7mm

915mm 467mm

820m

m

322m

m32

2mm

647m

m

1200mm Two DoorTwo Drawers

1200mm 466mm

820m

m64

7mm

322m

m32

2mm

750

460

�38

230

�50

120

65

440

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-001-A

2010.12.13

JL

NONE

750x460x180mm basin

EP ISSUE EP-9075E 2010.12.13

900

460

�3855

230

�50

120

65

470

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-002-A

2010.12.13

JL

NONE

900x460x180mm basin

EP ISSUE EP-9090E 2010.12.13

1200

460

�385523

0

�50

120

65

500

18

280

180

ASAQ Trading, Co., Ltd.Rm 607- 608No. 388 BuildingFushan RoadPudong New AreaShanghai, China 200122

Tel 86 21 6105 7370Fax 86 21 6105 7372Web www.asaq.com.cn

NO.

1

2

MODIFICATION DRAWER DATE

MATERIAL:

SCALE:

DRAWER: DRAWING NO. :

DATE:

TITLE:

Unit: mm

EP-D-003-A

2010.12.13

JL

NONE

1200x460x180mm single basin

EP ISSUE EP-9120E 2010.12.13

For all internal draw measurements see page 11.

NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

Page 9: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

7

TESSA TECHNICAL DRAWINGS

600mm One Drawer

900mm Two Drawer

1200mm One Drawer

600mm Two Drawer

900mm Two Drawer

1200mm Two Drawer

425

325

425

325

550 22

222

255

0 222

222

425

325

425

325

425

325

425

325

550 22

222

2

550 22

222

2

222

222

550

222

222

550

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

14

120

481200+4

0

450 +3-0

225±3

100 +1-2

91°

50±2

Ø35±1

110

55 20

490 490

525336

Fixing Holes

14

120

481200+4

0

450 +3-0

225±3

100 +1-2

91°

50±2

Ø35±1

110

55 20

490 490

525336

Fixing Holes

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

14

120

481200+4

0

450 +3-0

225±3

100 +1-2

91°

50±2

Ø35±1

110

55 20

490 490

525336

Fixing Holes

14

120

481200+4

0

450 +3-0

225±3

100 +1-2

91°

50±2

Ø35±1

110

55 20

490 490

525336

Fixing Holes

WALL HUNG UNITSFor all internal draw measurements see page 11.

Page 10: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

8

TESSA TECHNICAL DRAWINGS

1200mm Two DrawerSide by SideDouble Bowl

1500mm Two DrawerSide by SideDouble Bowl 42

5

325

425

325

120042

5

325

1200

425

325

1800mm Two DrawerSide by SideDouble Bowl

425

32542

5

425

32542

5

14

120

48

1800 +50

450 +30

225±2

Ø45±1

50±2

100 +1-2

Ø35±1

153±383°

83°

20160

150

100

450 900±2

100

48

500

R3

Ø35±1

110

55 20

790 790

200

Fixing Holes

14

120

48

1800 +50

450 +30

225±2

Ø45±1

50±2

100 +1-2

Ø35±1

153±383°

83°

20160

150

100

450 900±2

100

48

500

R3

Ø35±1

110

55 20

790 790

200

Fixing Holes

14

120

48

1500 +50

450 +30

225±2

50±2

100 +1-283° 83° 153±3

20160

150

100

375 750±2

500

48

100

R3

Ø35±1 Ø35±1

Ø45±1

110

55 20

640 640

125

Fixing Holes

14

120

48

1500 +50

450 +30

225±2

50±2

100 +1-283° 83° 153±3

20160

150

100

375 750±2

500

48

100

R3

Ø35±1 Ø35±1

Ø45±1

110

55 20

640 640

125

Fixing Holes

1200 +4-0

450 +3-0

100 +1-2

50±2

225±3

14

120

48

Ø35±1

Ø45±1

600±2

110

55 20

50050

490 490

Fixing Holes

1200 +4-0

450 +3-0

100 +1-2

50±2

225±3

14

120

48

Ø35±1

Ø45±1

600±2

110

55 20

50050

490 490

Fixing Holes

TESSA TECHNICAL DRAWINGSFloor Standing UNITS

600mm Two Drawer

322m

m32

2mm

322m

m32

2mm

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

600 +3-0

450 +3-0

50±2

225±314

120

48 100 +1-2

Ø35±1

500

110

55 20

380

Fixing Holes

900mm Two Drawer

322m

m32

2mm

322m

m32

2mm

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

900 +3-0

450 +3-0

50±2

225±3

100 +1-2

14

120

48

Ø35±1

526

110

55 2090°

680

Fixing Holes

WALL HUNG UNITS - ContinuedFor all internal draw measurements see page 11.

For all internal draw measurements see page 11.

NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

Page 11: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

9

TESSA TECHNICAL DRAWINGSFLOOR STANDING UNITS - Continued

1200mm 4 DrawersDouble Bowl

322m

m32

2mm

900m

m

322m

m32

2mm

900m

m

1200 +4-0

450 +3-0

100 +1-2

50±2

225±3

14

120

48

Ø35±1

Ø45±1

600±2

110

55 20

50050

490 490

Fixing Holes

1200 +4-0

450 +3-0

100 +1-2

50±2

225±3

14

120

48

Ø35±1

Ø45±1

600±2

110

55 20

50050

490 490

Fixing Holes

1500mm 4 DrawersDouble Bowl

322m

m32

2mm

900m

m

322m

m32

2mm

900m

m

14

120

48

1500 +50

450 +30

225±2

50±2

100 +1-283° 83° 153±3

20160

150

100

375 750±2

500

48

100

R3

Ø35±1 Ø35±1

Ø45±1

110

55 20

640 640

125

Fixing Holes

14

120

48

1500 +50

450 +30

225±2

50±2

100 +1-283° 83° 153±3

20160

150

100

375 750±2

500

48

100

R3

Ø35±1 Ø35±1

Ø45±1

110

55 20

640 640

125

Fixing Holes

1800mm 4 DrawersDouble Bowl

322m

m32

2mm

900m

m

322m

m32

2mm

900m

m

14

120

48

1800 +50

450 +30

225±2

Ø45±1

50±2

100 +1-2

Ø35±1

153±383°

83°

20160

150

100

450 900±2

100

48

500

R3

Ø35±1

110

55 20

790 790

200

Fixing Holes

14

120

48

1800 +50

450 +30

225±2

Ø45±1

50±2

100 +1-2

Ø35±1

153±383°

83°

20160

150

100

450 900±2

100

48

500

R3

Ø35±1

110

55 20

790 790

200

Fixing Holes

FURNITURE TECHNICAL DRAWINGSMETRO VANITY

500mmOne Door

500mm

480mm

490m

m

500mm

500mm

480mm

490m

m

500mm

For all internal draw measurements see page 11.

Page 12: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

10

FURNITURE TECHNICAL DRAWINGSTall Cabinet

1700mm (H)One DoorTwo Drawers

300mm 290mm

1700

mm

600mmTwo Door

MIRROR CABINETs

587mm 120mm

750m

m

900mmThree Door

880mm 120mm

750m

m

1200mmThree Door

1180mm 120mm

750m

m

NB: All measurements are nominal and may change from time to time. If a project requires specific measurements, please confirm with manufacturer first.

Page 13: TECHNICAL INSTALLATION INSTRUCTIONS€¦ · 13/12/2010  · TECHNICAL INSTALLATION INSTRUCTIONS • All products must be inspected before installation. MICO Distribution is not liable

11

INTERNAL DRAWER DETAILSFor full drawer units the internal drawer measurements vary however, the standard measurements are below;

Single Bowl (All one drawer models)

588

322

880

322

1180

322

250

150 150 150

160

165

441

SPLASH Drawer Wall Units Side View

250

Double Bowl (Two drawers side by side)

588

322

880

322

1180

322

250

150 150 150

160

165

441

SPLASH Drawer Wall Units Side View25

0

• Floor Units: U Bends in both drawers• Wall Units: In wall hung, 2 drawer models (over & under) U bend is in top drawer only.• U Bend is always in the centre of the basin

Double Bowl (Floor Standing Models)

150 150

266

278

27