TDX SP/SR Base Owner's Manual

84
Invacare® TDX® SP and TDX SR Power Wheelchair Base en TDX SP and TDX SR User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

Transcript of TDX SP/SR Base Owner's Manual

Page 1: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDXSR Power Wheelchair Base

en TDX SP and TDX SRUser Manual

This manual MUST be given to the user of the product.BEFORE using this product, read this manual and save for future reference.

Page 2: TDX SP/SR Base Owner's Manual

©2016 Invacare®CorporationAll rights reserved. Republication, duplication or modification in whole or in part is prohibited withoutprior written permission from Invacare. Trademarks are identified by ™and ®. All trademarks areowned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.

Page 3: TDX SP/SR Base Owner's Manual

Contents

1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.2 Reference Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.3 General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.3.1 Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.3.2 Transport - Wheelchair Tie-Down Restraints and

Seat Restraints (TRRO or TRBKTS) . . . . . . . . . . . . . . 91.3.3 Stairways and Escalators . . . . . . . . . . . . . . . . . . . . . . . 111.3.4 Repair and Service Information — Dealers and/or

Qualified Technicians. . . . . . . . . . . . . . . . . . . . . . . . . 121.3.5 Wear and Tear Information. . . . . . . . . . . . . . . . . . . . . 131.3.6 Global Limited Warranty (Excluding Canada) . . . . . . . . 131.3.7 Canada Limited Warranty . . . . . . . . . . . . . . . . . . . . . . 14

2 Safety Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.1 Safety/Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.1.1 A Note to Wheelchair Assistants. . . . . . . . . . . . . . . . . 172.1.2 Stability Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.1.3 Stability and Balance . . . . . . . . . . . . . . . . . . . . . . . . . . 182.1.4 Driving Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.1.5 Coping with Everyday Obstacles . . . . . . . . . . . . . . . . . 192.1.6 Negotiating Inclines. . . . . . . . . . . . . . . . . . . . . . . . . . . 202.1.7 Pinch Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.1.8 Footplates and Front Rigging . . . . . . . . . . . . . . . . . . . . 222.1.9 Reaching, Leaning and Bending - Forward . . . . . . . . . . . 222.1.10 Reaching, Bending - Backward . . . . . . . . . . . . . . . . . . 232.1.11 Transferring To and From Other Seats. . . . . . . . . . . . 242.1.12 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.1.13 Electrical - Grounding Instructions . . . . . . . . . . . . . . . 252.1.14 Electrical - Batteries . . . . . . . . . . . . . . . . . . . . . . . . . 262.1.15 Electrical - Charging Batteries . . . . . . . . . . . . . . . . . . 26

2.1.16 Recycling Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . 282.1.17 Weight Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.1.18 Weight Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.1.19 Electromagnetic Interference (EMI) From Radio

Wave Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.1.20 Powered Wheelchair Electromagnetic Interference

(EMI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

3 Label Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.1 All Wheelchairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.2 Wheelchairs with TRRO . . . . . . . . . . . . . . . . . . . . . . . . . 33

4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1.1 Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1.2 Overall Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1.3 Seat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1.4 Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.5 Axle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.6 Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.7 Footrests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.8 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374.1.9 Weight Capacity Warnings . . . . . . . . . . . . . . . . . . . . . 374.1.10 Weight Capacity Values. . . . . . . . . . . . . . . . . . . . . . . 37

5 Wheelchair Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.1 Preparing the Joystick for Use. . . . . . . . . . . . . . . . . . . . . . 395.2 Turning the Power On/Off . . . . . . . . . . . . . . . . . . . . . . . . 405.3 Using the Joystick to Drive the Wheelchair . . . . . . . . . . . . 405.4 SPJ+™, MK6i™ SPJ+ w/PSS and MK6i SPJ+ w/ACC

Joystick Switches and Indicators . . . . . . . . . . . . . . . . . . . 415.4.1 On/Off Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415.4.2 Speedometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415.4.3 Speed Control Buttons . . . . . . . . . . . . . . . . . . . . . . . 425.4.4 Joystick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Page 4: TDX SP/SR Base Owner's Manual

5.4.5 Charger/Programming Input . . . . . . . . . . . . . . . . . . . . 425.4.6 Information Gauge Display . . . . . . . . . . . . . . . . . . . . . 425.4.7 Service Indicator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425.4.8 Mode Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

5.5 CMPJ+ Joystick, Switches and Indicators . . . . . . . . . . . . . . 435.5.1 On/Off - Drive Select Toggle Switch (CMPJ+

Joystick) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435.5.2 Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435.5.3 Joystick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435.5.4 Charger/Programming Input . . . . . . . . . . . . . . . . . . . . 435.5.5 LCD Display Screens . . . . . . . . . . . . . . . . . . . . . . . . . 445.5.6 User Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465.5.7 CMPJ+ Joystick - Programmable Mono Ports 1 and 2

with External Mode Switch . . . . . . . . . . . . . . . . . . . . 485.5.8 Remote On/Off Switch . . . . . . . . . . . . . . . . . . . . . . . . 485.5.9 Mode Switch (CMPJ+ Joystick). . . . . . . . . . . . . . . . . . . 485.5.10 Memory Card Slot . . . . . . . . . . . . . . . . . . . . . . . . . . 49

5.6 When to Charge Batteries . . . . . . . . . . . . . . . . . . . . . . . . 495.6.1 SPJ+, SPJ+ w/PSS and SPJ+ w/ACC Joysticks . . . . . . . . . 495.6.2 CMPJ+ Joystick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

5.7 Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505.7.1 Description and Use of Battery Chargers . . . . . . . . . . . 50

5.8 Disengaging/Engaging the Motor Lock Levers . . . . . . . . . . . 515.9 Disengaging/Engaging the Motor Lock Levers - TDX

SR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525.10 Disengaging/Engaging the Wheel locks . . . . . . . . . . . . . . . 525.10.1 Engaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525.10.2 Disengaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

5.11 Disengaging/Engaging the Wheel Hubs . . . . . . . . . . . . . . . 53

6 Transport Ready Option(TRRO). . . . . . . . . . . . . . . . . . . . 546.1 About Transport Ready Packages . . . . . . . . . . . . . . . . . . . 546.2 Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . 556.3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

6.4 Positioning the Wheelchair in the Vehicle . . . . . . . . . . . . . 566.5 Securement Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566.6 Securing the Wheelchair . . . . . . . . . . . . . . . . . . . . . . . . . 576.7 Securing the Occupant . . . . . . . . . . . . . . . . . . . . . . . . . . . 576.7.1 Wheelchair-Anchored Belts . . . . . . . . . . . . . . . . . . . . 576.7.2 Vehicle-Anchored Belts . . . . . . . . . . . . . . . . . . . . . . . . 586.7.3 Seating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596.7.4 Positioning Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

7 Setup and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 617.1 Setup/Delivery Inspection . . . . . . . . . . . . . . . . . . . . . . . . . 617.2 User/Attendant Inspection Checklists . . . . . . . . . . . . . . . . 617.2.1 Inspect/Adjust Weekly . . . . . . . . . . . . . . . . . . . . . . . . 617.2.2 Inspect/Adjust Monthly . . . . . . . . . . . . . . . . . . . . . . . . 617.2.3 Inspect/Adjust Periodically. . . . . . . . . . . . . . . . . . . . . . 62

7.3 Service Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 627.3.1 Six Month Inspection . . . . . . . . . . . . . . . . . . . . . . . . . 627.3.2 Inspect/Adjust Every 18 Months. . . . . . . . . . . . . . . . . . 637.3.3 Inspect/Adjust Every 2 Years . . . . . . . . . . . . . . . . . . . . 63

7.4 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637.4.1 Cleaning Upholstery, Cloth, Vinyl . . . . . . . . . . . . . . . . 647.4.2 Cleaning Metal Surfaces. . . . . . . . . . . . . . . . . . . . . . . . 647.4.3 Cleaning Plastic Surfaces . . . . . . . . . . . . . . . . . . . . . . . 64

7.5 Removing/Installing the Shrouds . . . . . . . . . . . . . . . . . . . . 647.5.1 Removing the Rear Shroud . . . . . . . . . . . . . . . . . . . . . 647.5.2 Installing the Rear Shroud . . . . . . . . . . . . . . . . . . . . . . 647.5.3 Removing/Installing the Front Shroud/Battery

Retention Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . 647.6 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657.7 Using the Proper Batteries . . . . . . . . . . . . . . . . . . . . . . . . 677.8 Removing/Installing the Batteries From/Into the

Wheelchair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687.8.1 Removing the Batteries from the Wheelchair . . . . . . . . 687.8.2 Installing Batteries into the Wheelchair . . . . . . . . . . . . 68

Page 5: TDX SP/SR Base Owner's Manual

7.9 Replacing Batteries and/or Battery Cables . . . . . . . . . . . . . 707.9.1 Cleaning Battery Terminals . . . . . . . . . . . . . . . . . . . . . 71

7.10 Adjusting Forks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717.11 Removing/Installing the Footboard or Adjusting the

Footboard Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727.12 Adjusting the Footboard Angle . . . . . . . . . . . . . . . . . . . . 737.13 Repositioning Joystick. . . . . . . . . . . . . . . . . . . . . . . . . . . 747.14 Disconnecting/Connecting the SPJ+ Joysticks . . . . . . . . . . 747.14.1 Disconnecting the SPJ+ Joysticks . . . . . . . . . . . . . . . . 747.14.2 Connecting the SPJ+ Joysticks . . . . . . . . . . . . . . . . . . 74

7.15 Disconnecting/Connecting the CMPJ+ Joysticks . . . . . . . . 757.15.1 Connecting the CMPJ+ Joysticks . . . . . . . . . . . . . . . . 757.15.2 Disconnecting the CMPJ+ Joysticks . . . . . . . . . . . . . . 75

8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 768.1 Driving Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 768.2 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 768.2.1 SPJ+, SPJ+ w/PSS or SPJ+ w/ACC Joysticks . . . . . . . . . . 768.2.2 CMPJ+ Joysticks or Displays . . . . . . . . . . . . . . . . . . . . 78

8.3 Checking Battery Charge Level . . . . . . . . . . . . . . . . . . . . . 818.4 Usability Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Page 6: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

1 General

1.1 SymbolsSignal symbols and/or words are used in this manual and apply tohazards or unsafe practices which could result in personal injury orproperty damage. See the information below for definitions of thesignal words.

DANGER!– Danger indicates a imminently hazardous situationwhich, if not avoided, could result in death or seriousinjury.

WARNING!– Warning indicates a potentially hazardous situationwhich, if not avoided, could result in death or seriousinjury.

CAUTION!– Caution indicates a potentially hazardous situationwhich, if not avoided, may result in property damageor minor injury or both.

IMPORTANT– Indicates a hazardous situation that could result indamage to property if it is not avoided.

Gives useful tips, recommendations and information forefficient, trouble-free use.

1.2 Reference DocumentsRefer to the table below for part numbers of additionaldocuments which are referenced in this manual.

MANUAL PART NUMBER

MK6i™ ElectronicsProgramming Guide

1141471

Adjustable ASBA Owner’sManual

1143192

Van Seat Owner’s Manual 1143195

Formula™ CG Seating System 1143155

Adjustable ASBA Service Manual 1143238

1.3 General GuidelinesThe safety section contains important information for the safeoperation and use of this product.

DANGER!Risk of Death, Injury or DamageImproper use of this product may cause injury or damage– If you are unable to understand the warnings, cautionsor instructions, contact a health care professional ordealer before attempting to use this equipment.

– DO NOT use this product or any available optionalequipment without first completely reading andunderstanding these instructions and any additionalinstructional material such as user manual, servicemanuals or instruction sheets supplied with thisproduct or optional equipment.

6 1143190-M~04

Page 7: TDX SP/SR Base Owner's Manual

General

DANGER!Risk of Death, Serious Injury, or DamageIncorrect repair and/or servicing of this wheelchairperformed by users/caregivers or unqualified technicianscan result in death, serious injury, or damage.– Users/Caregivers — DO NOT attempt to repairand/or service this wheelchair.

– Repair and/or service of this wheelchair MUST beperformed by a qualified technician. Contact a dealeror Invacare technician.

WARNING!– DO NOT connect any medical devices such asventilators, life support machines, etc. directly tothe batteries used to power the wheelchair. Thiscould cause unexpected failure of the device and thewheelchair.

WARNING!Risk of Serious Injury or DamageUse of non-Invacare accessories may result in seriousinjury or damage.– Invacare products are specifically designed andmanufactured for use in conjunction with Invacareaccessories. Accessories designed by othermanufacturers have not been tested by Invacare andare not recommended for use with Invacare products.

– DO NOT use non-Invacare accessories.– To obtain Invacare accessories, contact Invacare byphone or at www.invacare.com

DANGER!Risk of Death, Serious Injury, or DamageUse of incorrect or improper replacement (service)parts may cause death, serious injury, or damage.– Replacement parts MUST match original Invacareparts.

– ALWAYS provide the wheelchair serial number toassist in ordering the correct replacement parts.

WARNING!Risk of Serious Injury or DamageAttaching hardware that is loosely secured could causeloss of stability resulting in serious injury or damage.– After ANY adjustments, repair or service and beforeuse, make sure that all attaching hardware is tightenedsecurely.

DANGER!Risk of Death, Serious Injury, or DamageMissing attaching hardware could cause instabilityresulting in death, serious injury or damage.– Ensure all attaching hardware is present and tightenedsecurely

WARNING!Risk of Serious Injury or DamageLoss of power due to loose electrical connectionscould cause the wheelchair to suddenly stop resulting inserious injury or damage.– ALWAYS ensure that all electrical connections aretightly connected so they don’t vibrate loose.

1143190-M~04 7

Page 8: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

THE INFORMATION CONTAINED IN THIS DOCUMENTIS SUBJECT TO CHANGE WITHOUT NOTICE.

Check all parts for shipping damage and test before using.In case of damage, DO NOT use. Contact Invacare/Carrierfor further instruction

As a manufacturer of wheelchairs, Invacare endeavors tosupply a wide variety of wheelchairs to meet many needsof the end user. However, final selection of the type ofwheelchair to be used by an individual rests solely withthe user and his/her healthcare professional capable ofmaking such a selection. Invacare recommends workingwith a qualified rehab technology provider, such as an ATP,(Assisstive Technology Professional).

1.3.1 Set Up

WARNING!Risk of Injury or DamageIncorrect set up of this wheelchair performed byusers/caregivers or unqualified technicians can result ininjury or damage.– User/Caregivers- DO NOT attempt to set up thiswheelchair.

– Initial set up of this wheelchair MUST be performedby a qualified technician.

DANGER!Risk of Death, Serious Injury, or DamageContinued use of the wheelchair that is not set to thecorrect specifications may cause erratic behavior of thewheelchair resulting in death, serious injury, or damage.– Performance adjustments should only be made byprofessionals of the healthcare field or personsfully conversant with this process and the driver'scapabilities.

– After the wheelchair has been set up/adjusted, checkto make sure that the wheelchair performs to thespecifications entered during the set up procedure. Ifthe wheelchair does not perform to specifications,turn the wheelchair Off immediately and reenter setup specifications. Contact Invacare, if wheelchair stilldoes not perform to correct specifications.

WARNING!Risk of Serious Injury or DamageMoving the seating system from the factory setting mayreduce driver control, wheelchair stability, tractionand increase caster wear resulting in serious injury ordamage.– Move the seating system ONLY when necessary to fitthe wheelchair to the user.

– If the seating system must be moved, ALWAYS inspectthe wheelchair to ensure the front rigging DOES NOTinterfere with the front casters.

– If the seating system must be moved, ALWAYSinspect to ensure the wheelchair DOES NOT easilytip forward or backward.

8 1143190-M~04

Page 9: TDX SP/SR Base Owner's Manual

General

DANGER!Risk of Death, Serious Injury or DamageOperating the wheelchairs outdoor or in areas of poorlighting may result in death, serious injury, or damage.Operating the wheelchair near motor vehicles may resultin death, serious injury or damage.– DO NOT operate on roads, streets or highways.– Use caution when operating the wheelchair outdoorsat night or in areas with poor lighting.

– ALWAYS be aware of motor vehicles when using thewheelchair.

WARNING!Risk of Minor to Serious InjuryPinch points can cause minor to serious injury.– Be mindful of potential pinch points and use cautionwhen using this product.

WARNING!Risk of Serious InjuryImpacting objects in the surrounding environment cancause serious injury.– When maneuvering the wheelchair around, ALWAYShave assured cleared distance with all objects inenvironment.

WARNING!Risk of Serious InjurySharp edges can cause serious injury.– Be mindful that some parts may have sharp edges. Usecaution when encountering these sharp edges.

WARNING!Risk of Serious InjuryHot surfaces can cause severe burns.– Be mindful of potential hot surfaces and avoid touching.

DANGER!Risk of Death, Serious Injury, or DamageLighted cigarettes dropped onto an upholstered seatingsystem can cause a fire resulting in death, serious injury,or damage.Wheelchair occupants are at particular risk of deathor serious injury from these fires and resulting fumesbecause they may not have the ability to move awayfrom the wheelchair.– DO NOT smoke while using this wheelchair.

1.3.2 Transport - Wheelchair Tie-Down Restraintsand Seat Restraints (TRRO or TRBKTS)

WARNING!Risk of Death, Serious Injury, or PropertyDamageFailure to observe the following transport warnings mayresult in death, serious injury, or property damage.

1143190-M~04 9

Page 10: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

WARNING!– Only use the transport brackets included with TRROor TRBKTS for the purposes described in this manual.

– TRRO (Transport Ready Option) - TRRO includesfour factory-installed transport brackets and awheelchair anchored pelvic belt. TRRO has beencrash-tested in accordance with ANSI/RESNA WCVol 1 Section 19 Frontal Impact Test requirements forwheelchairs with a 130 lb (59 kg) crash test dummy,which corresponds to a person with a weight of 125lbs (57 kg) to 165 lbs (75 kg) for Junior seat sizes ora 168 lb (76 kg) crash dummy, which corresponds toa person with a weight of 165 lbs (75 kg) to 300 lbs(136 kg) for Adult seat sizes.

– TRBKTS (Wheelchair Transport Brackets) - TRBKTSincludes four factory-installed wheelchair transportbrackets. TRBKTS has not been crash-tested inaccordance with WC 19. Use these transportbrackets only to secure an unoccupied wheelchairduring transport.

WARNING!– As of this date, the Department of Transportation hasnot approved any tie-down systems for transportationof a user while in a wheelchair, in a moving vehicleof any type. It is Invacare’s position that users ofwheelchairs should be transferred into appropriateseating in vehicles for transportation and use bemade of the restraints made available by the autoindustry. Invacare cannot and does not recommendany wheelchair transportation systems.

– Battery support brackets MUST be installed at alltimes. Otherwise, the wheelchair will not be WC/19compliant. Refer to the Transport section in the baseuser manual that was shipped with the product formore information about transporting the wheelchair.

10 1143190-M~04

Page 11: TDX SP/SR Base Owner's Manual

General

1.3.3 Stairways and Escalators

WARNING!– DO NOT attempt to move an occupied powerwheelchair between floors using a stairway. Use anelevator to move an occupied power wheelchairbetween floors.

– If moving a power wheelchair between floors by meansof a stairway, the occupant MUST be removed andtransported independently of the power wheelchair.

– Extreme caution is advised when it is necessary tomove an unoccupied power wheelchair up or downthe stairs. Invacare recommends using two assistantsand making thorough preparations. Make sure to useONLY secure, non-detachable parts for hand-holdsupports.

– DO NOT use an escalator to move a wheelchairbetween floors. Serious bodily injury may occur.

– DO NOT attempt to lift the wheelchair by anyremovable (detachable) parts. Lifting by means ofany removable (detachable) parts of a wheelchairmay result in injury to the user or damage to thewheelchair.

– The weight of the wheelchair varies depending on themodel. Refer to the Technical Data section of thismanual for the weight of the wheelchair. ALWAYSuse proper lifting techniques (lift with your legs) toavoid injury.

Follow this procedure for moving the wheelchair between floorswhen an elevator is NOT available:

When using a stairway to move the wheelchair and anyaccessories, move all wheelchair components away from thestairway prior to reassembly.

1. Remove the occupant from the wheelchair.2. Remove the batteries from wheelchair. Refer to Removing the

Batteries procedure in this manual.3. Bend your knees and keep your back straight.4. Using non-removable (non-detachable) parts of the wheelchair,

lift the wheelchair off of the ground and transfer the wheelchairup or down the stairs.

5. The wheelchair should not be lowered until the last stair hasbeen negotiated and the wheelchair has been carried away fromthe stairway.

1143190-M~04 11

Page 12: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

1.3.4 Repair and Service Information — Dealersand/or Qualified Technicians

WARNING!Risk of Serious Injury or Damage– DO NOT service or operate this equipment withoutfirst reading and understanding (1) the user manual, (2)the service manual (if applicable) and (3) the seatingsystem’s manual (if applicable). If you are unable tounderstand the warnings, cautions and instructions,contact Invacare technical support before attemptingto service or operate this equipment.

– Set up of the driver control is to be performed onlyby a qualified technician. The final adjustments ofthe driver control may affect other activities of thewheelchair. Serious injury or damage to the equipmentcould occur if improperly set up or adjusted.

– Except for programming, DO NOT service or adjustthe wheelchair while occupied, unless otherwisenoted.

– Before adjusting, repairing or servicing the wheelchair,ALWAYS turn the wheelchair power Off.

DANGER!Risk of Death, Serious Injury, or DamageCorroded electrical components due to water, liquidexposure, or incontinent users can result in death,serious injury, or damage.– Minimize exposure of electrical components to waterand/or liquids. Electrical components damaged bycorrosion MUST be replaced immediately.

– Wheelchairs that are used by incontinent usersand/or are frequently exposed to water/liquids mayrequire replacement of electrical components morefrequently.

WARNING!– DO NOT overtighten hardware attaching to theframe. This could cause damage to the frame tubing.

– Transport ready packages are not able to be retrofittedto existing models and are not field serviceable.

– Replace gas-locking cylinders every two years or ifperformance issues are encountered. Performanceissues include forward tipping and veering.

12 1143190-M~04

Page 13: TDX SP/SR Base Owner's Manual

General

1.3.5 Wear and Tear InformationGeneral Information

Normal wear and tear items and components include but are notlimited to: all upholstery items including seat and back upholstery,arm and calf pads, cushions, wheels, tires and casters, all types ofbatteries, joystick overlays and inductive rubberized protective boots.

Invacare reserves the right to ask for any item back that has analleged defect in workmanship. Refer to the Warranty section in thismanual for specific warranty information.

Refer to the Inspection Checklists for proper preventativemaintenance schedule.

This is just a general guideline and does not include items damageddue to abuse and misuse.

Product Type Product Wear and Tear

Wheelchairs Wheels, Brake Assembly, Hand Grips

Scooters Wheels, Braking System, Armrest, Seat

Mobility Hardwareand Electronics

Rubber Urethane Tires and Casters,Handgrips, Joystick Inductive Tops,Joystick Overlays, Motors andGearboxes (if exposed to prolongedmoisture, urine, etc.), Stability Lock

Upholstery andSeating

Arm pads, Seat Cushion Foam, SeatCushion Covers, Back Cushion Foam,Back Cushion Covers, Headrest Foam,Headrest Covers, Footplate Covers,Calf Pad (if applicable)Foam and Cover

Batteries Lead acid/Lithium, Coin cell (watchtype), Gel (6 months)

1.3.6 Global Limited Warranty (Excluding Canada)PLEASE NOTE: THE WARRANTY BELOW HASBEEN DRAFTED TO COMPLY WITH FEDERAL LAWAPPLICABLE TO PRODUCTS MANUFACTURED AFTERJULY 4, 1975.

This warranty is extended only to the original purchaser whopurchases this product within any country excluding CANADAwhen new and unused from Invacare or a dealer. This warranty isnot extended to any other person or entity and is not transferableor assignable to any subsequent purchaser or owner. Coverageunder this warranty will end upon any such subsequent sale or othertransfer of title to any other person. For product purchased inCanada, please refer to the Canada Limited Warranty.

This warranty gives you specific legal rights and you may also haveother legal rights which vary from state to state.

Invacare warrants the base frame to be free from defects in materialsand workmanship for a period of five (5) years from the date ofpurchase from Invacare or a dealer, with a copy of the seller’s invoicerequired for coverage under this warranty. Invacare warrants allelectronics and electrical components (excluding batteries), motors,powered seating actuators and gearboxes to be free from defects inmaterials and workmanship for a period of one (1) year from thedate of purchase from Invacare or a dealer, with a copy of the seller’sinvoice required for coverage under this warranty. Invacare warrantsall batteries to be free from defects in materials and workmanship fora period of six (6) months from the date of purchase from Invacareor a dealer, with a copy of the seller’s invoice required for coverageunder this warranty. Invacare warrants all remaining components(excluding all upholstered materials, padded materials, tires andwheels) to be free from defects in materials and workmanship for aperiod of one (1) year from the date of purchase from Invacare or

1143190-M~04 13

Page 14: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

a dealer, with a copy of the seller’s invoice required for coverageunder this warranty. If within such warranty periods any suchproduct component shall be proven to be defective, the productcomponent shall be repaired or replaced, at Invacare's option. Thiswarranty does not include any labor or shipping charges incurred inreplacement part installation or repair of any such product. Invacare'ssole obligation and your exclusive remedy under this warranty shallbe limited to such repair and/or replacement.

For warranty service, please contact the dealer from whom youpurchased your Invacare product. In the event you do not receivesatisfactory warranty service, please write directly to Invacare atthe address on the bottom of the back cover. Provide dealer'sname address, date of purchase, indicate nature of the defect and, ifthe product is serialized, indicate the serial number. Do not returnproducts to our factory without our prior consent.

Limitations and Exclusions: The foregoing warranty shall not applyto serial numbered products if the serial number has been removedor defaced, products subject to negligence, accident, improperoperation, maintenance or storage, commercial or institutionaluse, products modified without Invacare's express written consent(including, but not limited to, modification through the use ofunauthorized parts or attachments); products damaged by reasonof repairs made to any component without the specific consentof Invacare, or to a product damaged by circumstances beyondInvacare's control, and such evaluation will be solely determinedby Invacare. The warranty shall not apply to problems arisingfrom normal wear and tear or failure to adhere to the productinstructions. A change in operating noise, particularly relative tomotors and gearboxes does not constitute a failure or defect andwill not be repaired; all devices will exhibit changes in operatingnoise due to aging.

The foregoing express warranty is exclusive and in lieu of any otherwarranties whatsoever, whether express or implied, including theimplied warranties of merchantability and fitness for a particularpurpose, and the sole remedy for violations of any warrantywhatsoever, shall be limited to repair or replacement of the defectiveproduct pursuant to the terms contained herein. The applicationof any implied warranty whatsoever shall not extend beyond theduration of the express warranty provided herein and Invacare shallnot be liable for any consequential or incidental damages whatsoever;SOME STATES DO NOT ALLOW THE EXCLUSION ORLIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE,OR LIMITATION OF HOW LONG AN IMPLIED WARRANTYLASTS, SO THE ABOVE EXCLUSION AND LIMITATION MAYNOT BE APPLICABLE.

THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITHSTATE/PROVINCIAL LAWS AND REQUIREMENTS.

1.3.7 Canada Limited WarrantyThis warranty is extended only to the original purchaser whopurchases this product within Canada when new and unusedfrom Invacare or a dealer. This warranty is not extended to anyother person or entity and is not transferable or assignable to anysubsequent purchaser or owner. Coverage under this warranty willend upon any such subsequent sale or other transfer of title to anyother person.

This warranty gives you specific legal rights and you may also haveother legal rights which vary from state to state.

Invacare warrants the base frame to be free from defects in materialsand workmanship for a period of five (5) years from the date ofpurchase from Invacare or a dealer, with a copy of the seller’s invoicerequired for coverage under this warranty. Invacare warrants allelectronics and electrical components (excluding batteries), powered

14 1143190-M~04

Page 15: TDX SP/SR Base Owner's Manual

General

seating actuators, 2-pole motors and gearboxes to be free fromdefects in materials and workmanship for a period of two (2) yearsfrom the date of purchase from Invacare or a dealer, with a copyof the seller’s invoice required for coverage under this warranty.Invacare warrants all batteries to be free from defects in materialsand workmanship for a period of six (6) months from the date ofpurchase from Invacare or a dealer, with a copy of the seller’s invoicerequired for coverage under this warranty. Invacare warrants allremaining components (excluding all upholstered materials, paddedmaterials, tires and wheels) to be free from defects in materials andworkmanship for a period of one (1) year from the date of purchasefrom Invacare or a dealer, with a copy of the seller’s invoice requiredfor coverage under this warranty. If within such warranty periods anysuch product component shall be proven to be defective, the productcomponent shall be repaired or replaced, at Invacare's option. Thiswarranty does not include any labor or shipping charges incurred inreplacement part installation or repair of any such product. Invacare'ssole obligation and your exclusive remedy under this warranty shallbe limited to such repair and/or replacement.

For warranty service, please contact the dealer from whom youpurchased your Invacare product. In the event you do not receivesatisfactory warranty service, please write directly to Invacare atthe address on the bottom of the back cover. Provide dealer'sname address, date of purchase, indicate nature of the defect and, ifthe product is serialized, indicate the serial number. Do not returnproducts to our factory without our prior consent.

Limitations and Exclusions: The foregoing warranty shall not applyto serial numbered products if the serial number has been removedor defaced, products subject to negligence, accident, improperoperation, maintenance or storage, commercial or institutionaluse, products modified without Invacare's express written consent(including, but not limited to, modification through the use of

unauthorized parts or attachments); products damaged by reasonof repairs made to any component without the specific consentof Invacare, or to a product damaged by circumstances beyondInvacare's control, and such evaluation will be solely determinedby Invacare. The warranty shall not apply to problems arisingfrom normal wear and tear or failure to adhere to the productinstructions. A change in operating noise, particularly relative tomotors and gearboxes does not constitute a failure or defect andwill not be repaired; all devices will exhibit changes in operatingnoise due to aging.

The foregoing express warranty is exclusive and in lieu of any otherwarranties whatsoever, whether express or implied, including theimplied warranties of merchantability and fitness for a particularpurpose, and the sole remedy for violations of any warrantywhatsoever, shall be limited to repair or replacement of the defectiveproduct pursuant to the terms contained herein. The applicationof any implied warranty whatsoever shall not extend beyond theduration of the express warranty provided herein and Invacare shallnot be liable for any consequential or incidental damages whatsoever;SOME STATES DO NOT ALLOW THE EXCLUSION ORLIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE,OR LIMITATION OF HOW LONG AN IMPLIED WARRANTYLASTS, SO THE ABOVE EXCLUSION AND LIMITATION MAYNOT BE APPLICABLE.

THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITHSTATE/PROVINCIAL LAWS AND REQUIREMENTS.

1143190-M~04 15

Page 16: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

2 Safety Handling

2.1 Safety/Handling“Safety and Handling” of the wheelchair requires the close attentionof the wheelchair user as well as the assistant. This manual pointsout the most common procedures and techniques involved in thesafe operation and maintenance of the wheelchair. It is important topractice and master these safe techniques until you are comfortablein maneuvering around the frequently encountered architecturalbarriers.

Use this information only as a “basic” guide. The techniques that arediscussed on the following pages have been used successfully by many.

Users and assistants must be aware that the handling andmaneuverability characteristics of front wheel drive wheelchairs areinherently different from center and rear wheel drive wheelchairs.Handling and maneuverability differences will be most noticeablewhen traveling down declines (Example: ramps and slopes) or overobstacles and rough terrain as this may shift the users center of massforward resulting in decreased stability. ALWAYS reduce speed andwear the seat positioning strap when driving under these conditions.

Individual wheelchair users often develop skills to deal with dailyliving activities that may differ from those described in this manual.Invacare recognizes and encourages each individual to try what worksbest for him/her in overcoming architectural obstacles that they mayencounter. However all warnings and cautions given in this manualMUST be followed. Techniques in this manual are a starting pointfor the new wheelchair user and assistant with “safety” as the mostimportant consideration for all.

Invacare strongly recommends that initial use of front wheel drivewheelchairs be supervised by an assistant.

DANGER!Risk of Death, Serious Injury, or DamageMisuse of the wheelchair may cause component failureand/or the wheelchair to start smoking, sparking, orburning. Death, serious injury, or damage may occurdue to fire.– DO NOT use the wheelchair other than its intendedpurpose. If the wheelchair starts smoking, sparking, orburning, discontinue using the wheelchair and seekservice IMMEDIATELY.

DANGER!Risk of Death or Serious InjuryNot wearing your seat positioning strap could result indeath or serious injury.– ALWAYS wear your seat positioning strap. Yourseat positioning strap helps reduce the possibilityof a fall from the wheelchair. The seat positioningstrap is a positioning belt only. It is not designed foruse as a safety device withstanding high stress loadssuch as auto or aircraft safety belts. If signs of wearappear, seat positioning strap MUST be replacedIMMEDIATELY.

16 1143190-M~04

Page 17: TDX SP/SR Base Owner's Manual

Safety Handling

WARNING!– DO NOT leave the power button On when enteringor exiting your wheelchair.

– DO NOT go up or down ramps or traverse slopesgreater than 9°.

– Never leave an unoccupied wheelchair unattended onan incline.

– Determine and establish your particular safety limits bypracticing bending, reaching and transferring activitiesin the presence of a qualified healthcare professionalbefore attempting active use of the wheelchair.

– Always shift your weight in the direction you areturning. Do not shift your weight in the oppositedirection of the turn. Shifting your weight in theopposite direction of the turn may cause the insidedrive wheel to lose traction and the wheelchair totip over.

– DO NOT shift your weight or sitting position towardthe direction you are reaching as the wheelchairand/or seating system (if any) may tip over.

– Always keep hands and fingers clear of moving partsto avoid injury.

– DO NOT use with a broken or missing joystick knob.– DO NOT use if joystick does not spring back to theneutral position or becomes sticky or sluggish.

– DO NOT use if joystick boot is torn or damaged.– Always check foam grips for looseness before usingthe wheelchair. If loose, contact a qualified technicianfor instructions.

WARNING!– DO NOT attempt to stop a moving wheelchair withthe wheel locks. Wheel locks are not brakes.

– DO NOT engage or disengage the motor locks untilthe power is in the off position.

– If wheelchair is equipped with pneumatic tires - DONOT use your wheelchair unless it has the propertire pressure (P.S.I.). DO NOT overinflate thetires. Failure to follow these recommendations maycause the tire to explode and cause bodily harm.The recommended tire pressure is 35 p.s.i. (24kilopascals). The recommended tire pressure is alsolisted on the side wall of the tire

WARNING!Risk of Serious Injury or DamageAccidental activation of wheelchair caused by pets,children, etc. can result in serious injury or damage.– ALWAYS turn power off when around pets and/orchildren to prevent unintended movement.

2.1.1 A Note to Wheelchair AssistantsWhen assistance to the wheelchair user is required, remember touse good body mechanics. Keep your back straight and bend yourknees whenever tilting wheelchair or traversing curbs or otherimpediments.

WARNING!– Also, be aware of detachable parts such as arms orlegrests. These MUST NEVER be used to move thewheelchair or as lifting supports, as they may beinadvertently released, resulting in possible injury tothe user and/or assistant(s).

1143190-M~04 17

Page 18: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

When learning a new assistance technique, have an experiencedassistant help you before attempting it alone.

2.1.2 Stability Lock

DANGER!Risk of Death or Serious InjuryNot performing periodic maintenance on stability lockcould result in death or serious injury.– ALWAYS perform the periodic maintenance to thestability lock listed in the inspection checklist of thismanual.

2.1.3 Stability and BalanceTo assure stability and proper operation of your wheelchair, youMUST at all times maintain proper balance. Your wheelchair hasbeen designed to remain upright and stable during normal dailyactivities as long as you DO NOT move beyond the center of gravity.DO NOT lean forward out of the wheelchair any further than thelength of the armrests.

The drive behavior initially experienced by the user may be differentfrom other wheelchairs previously used. This power wheelchairhas Invacare’s SureStep® technology, a feature that provides thewheelchair with optimum traction and stability when driving forwardover transitions and thresholds. Refer to Coping with EverydayObstacles for maximum height of transitions and thresholds. Thefollowing warnings apply specifically to the SureStep feature:

WARNING!– To determine and establish your particular safetylimits, practice use of this product on various slopingsurfaces in the presence of a qualified healthcareprovider before attempting active use of thiswheelchair. Other general warnings listed within thisdocument also apply.

– ALWAYS reduce speed when traveling up or down anincline or over obstacles and rough terrain. Travelingunder these conditions may shift the users weightforward resulting in reduced stability.

WARNING!– DO NOT leave elevating legrests in the fully extendedposition when proceeding down ramps or slopes.

– Be aware that carrying heavy objects on your lapwhile occupying the wheelchair may adversely affectthe stability of the wheelchair, resulting in seriousbodily injury to the user, damage to the wheelchairand surrounding property.

WARNING!Risk of Injury or DamageThis wheelchair has been designed to accommodateone individual. If more than one individual occupiesthe wheelchair this may adversely affect the stability ofthe wheelchair, resulting in serious bodily injury to theuser and passenger and damage to the wheelchair andsurrounding property.– DO NOT have more than one individual occupy thewheelchair.

– DONOT have any one stand on the frame at any time.

18 1143190-M~04

Page 19: TDX SP/SR Base Owner's Manual

Safety Handling

2.1.4 Driving SurfacesYour power wheelchair has been designed to operate on dry, levelsurfaces (i.e. concrete, blacktop, and asphalt). Other acceptablesurfaces likely to be encountered include packed soil, grass, andgravel.

Avoid driving on the following surfaces:

• Uneven terrain, soft surfaces• Tall grass• Loose gravel and/or sand• Do not operate the wheelchair in any type or depth of water

(edges of streams, lakes, or oceans.)• If you approach an unfamiliar surface and feel uneasy about

driving on that surface, avoid that surface.

2.1.5 Coping with Everyday ObstaclesCoping with the irritation of everyday obstacles can be somewhatalleviated by learning how to manage your wheelchair. Keep in mindyour center of gravity to maintain stability and balance.

While the wheelchair is designed for use primarily in and aroundthe home, the provider should determine whether this wheelchairis suitable for the actual environment in which the wheelchair willbe used.

WARNING!Risk of Serious Injury or DamageDriving (forward or reverse) down off *curbs/obstaclesA greater than 70mm (2.76 inches) B may cause yourwheelchair to turn over and cause serious injury ordamage to the wheelchair.– DO NOT attempt to drive down off curbs/obstaclesgreater than 70mm (2.76 inches).

– ALWAYS stop before negotiating an obstacle.– Approach slowly until caster wheels are approximately18 inches (46 cm) away from the obstacle. Slowly applypower to move forward/reverse while negotiating theobstacle.

1143190-M~04 19

Page 20: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

WARNING!Risk of Serious Injury or DamageSerious injury or damage to the wheelchair may resultfrom driving forward up over *curbs/obstaclesC greaterthan 70mm (2.76 inches) D or driving reverse up over*curbs/obstacles C greater than 40mm (1.57 inches) D.– DO NOT attempt to drive up over *curbs/obstaclesgreater than 70mm (2.76 inches) going forward or40mm (1.57 inches) in reverse.

– ALWAYS stop before negotiating an obstacle.– Approach slowly until caster wheels are approximately18 inches (46 cm) away from the obstacle. Slowly applypower to move forward/reverse while negotiating theobstacle.

* Improved performance can be achieved when climbing over rolledcurbs E.

2.1.6 Negotiating Inclines

Acceptable Incline Angles0° to 9°

Avoid Inclines of 10°and above

WARNING!Risk of Death or Serious InjuryTraversing inclines greater than 9° could impair lineof sight required for safe driving, resulting in death orserious injury.– DO NOT use on inclines greater than 9°.– If line of sight is impaired, DO NOT traverse anyincline.

20 1143190-M~04

Page 21: TDX SP/SR Base Owner's Manual

Safety Handling

WARNING!Risk of Death or Serious InjuryTraversing inclines with the seat reclined could causeyour wheelchair to become unstable and tip overresulting in death or serious injury.– DO NOT attempt to traverse inclines with the seatreclined.

DANGER!Risk of Death or Serious InjuryTraveling on inclines with wet, slippery, icy or oilysurfaces could cause loss of traction resulting in deathor serious injury.– DO NOT use on inclines with wet, slippery, icy oroily surfaces. This may include certain painted orotherwise treated wood surfaces.

DANGER!Risk of Death or Serious InjuryTraveling down inclines in reverse could cause thewheelchair to tip over resulting in death or serious injury– DO NOT travel down inclines in reverse.

WARNING!Risk of Death or Serious InjuryBraking hard and/or sudden stops while on inclines couldcause loss of stability resulting in death or serious injury.– While on inclines, ALWAYS travel at a reduced,constant speed to maintain stability. Traveling downramps at high speeds will reduce traction and increasestopping distance.

– DO NOT brake hard and avoid sudden stops whiletraveling on an incline.

– If stopping becomes necessary while on an incline,release the joystick and allow the wheelchair to cometo a full stop. Then proceed at a slower speed.

WARNING!Risk of Death or Serious InjuryDriving in an elevated position while on an incline couldcause loss of stability resulting in death or serious injury.– DO NOT drive in an elevated position while on anincline.

1143190-M~04 21

Page 22: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

2.1.7 Pinch Points

WARNING!Risk of InjuryPinch Point– Be aware that a pinch point exists between head tubecap A and walking beam B.

– Be aware that a pinch point exist between walkingbeam/head tube cap and telescoping tube C when thewheelchair is at the lowest seat to floor height.

– Be aware that a pinch point may occur when rotatingthe center mount front rigging assembly D.

2.1.8 Footplates and Front Rigging

WARNING!Risk of Serious Injury or DamageOperating the wheelchair with a ground clearance ofless than 75 mm (3 inches) between the footplates andthe ground/floor may cause serious injury or propertydamage.– ALWAYS maintain a minimum of 75 mm (3inches) between the bottom of the footplates andground/floor to ensure proper ground clearance whilethe wheelchair is in motion. If necessary, adjust thefootplates height to achieve proper ground clearance.After footplates height adjustment, if the wheelchairdips forward and the footplates touch the groundwhile in motion, please contact your dealer for aninspection and avoid use of the wheelchair if possible.

2.1.9 Reaching, Leaning and Bending - ForwardMany activities require the wheelchair user to reach, bend andtransfer in and out of the wheelchair. These movements will causea change to the normal balance, center of gravity, and weightdistribution of the wheelchair. To determine and establish yourparticular safety limits, practice bending, reaching and transferringactivities in several combinations in the presence of a qualifiedhealthcare professional before attempting active use of the wheelchair

22 1143190-M~04

Page 23: TDX SP/SR Base Owner's Manual

Safety Handling

WARNING!Risk of Serious Injury or DamageImproper positioning while leaning or bending couldcause the wheelchair to tip forward resulting in seriousinjury or damage.– To assure stability and proper operation of yourwheelchair, you MUST at all times maintain properbalance. Your wheelchair has been designed to remainupright and stable during normal daily activities as longas you DO NOT move beyond the center of gravity.DO NOT lean forward out of the wheelchair anyfurther than the length of the armrests.

– DO NOT attempt to reach objects if you have tomove forward in the seat or pick them up from thefloor by reaching down between your knees.

Engage motor locks and turn power off before reaching, leaning orbending only as far as your arm will extend without changing yoursitting position. Position the casters so that they are extended awayfrom the drive wheels and engage wheel locks/motor locks/clutches.

2.1.10 Reaching, Bending - Backward

WARNING!Risk of Serious Injury or DamageLeaning backward over the top of the seat back willchange your center of gravity and may cause you to tipover resulting in serious injury or damage.– Proper positioning is essential for your safety. DONOT lean over the top of the seat back.

Position wheelchair as close as possible to the desired object.Position the casters so that they are extended away from the drivewheels to create the longest possible wheelbase, engage the motorlocks and turn power off. Reach back only as far as your arm willextend without changing your sitting position.

1143190-M~04 23

Page 24: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

2.1.11 Transferring To and From Other Seats

TOP VIEW

FRONT VIEW

WARNING!Risk of Serious Injury or DamageImproper transfer techniques may cause serious injuryor damage.– Before attempting transfers, consult a health careprofessional to determine proper transfer techniquesfor the user and type of wheelchair.

– Reduce gap between transfer surface and wheelchairseat to the minimum distance necessary to performtransfer.

– Align casters parallel to the drive wheels to improvestability during transfer.

– ALWAYS turn the wheelchair power off.– ALWAYS engage both motor locks/clutches andfree wheel hubs (if equipped) to prevent the wheelsfrom moving before transferring into or from thewheelchair.

Adequate mobility and upper body strength is required toperform this activity independently.

1. Position the wheelchair to minimize the gap distance between thetransporter seat and the seat to which you are transferring to.

2. Ensure the casters are aligned parallel with the object.3. Engage motor locks. Refer to Disengaging/Engaging Motor Locks.4. Shift body weight into seat with transfer

During independent transfer, little or no seat platformwill be beneath you. Use a transfer board if at allpossible.

24 1143190-M~04

Page 25: TDX SP/SR Base Owner's Manual

Safety Handling

2.1.12 Storage

WARNING!Risk of Serious Injury or DamageStoring or using the wheelchair near open flame orcombustible products can result is serious injury ordamage.– Avoid storing or using the wheelchair near open flameor combustible products.

CAUTION!Risk of DamageOperating the wheelchair in rain or dampness maycause the wheelchair to malfunction electrically andmechanically; may cause the wheelchair to prematurelyrust or may damage the upholstery.– DO NOT leave wheelchair in a rain storm of any kind.– DO NOT use wheelchair in a shower.– DO NOT leave wheelchair in a damp area for anylength of time.

– Check to ensure that the battery covers are securedin place, joystick boot is NOT torn or cracked wherewater can enter and that all electrical connections aresecure at all times. DO NOT use if the joystick bootis torn or cracked. If the joystick boot becomes tornor cracked, replace IMMEDIATELY.

Leakage current has been tested in accordance to ISO7176–14:2008.

Invacare has tested its power wheelchairs in accordancewith RESNA Section 9 “Rain Test”.

DANGER!

Risk of Death, Serious Injury, or DamageEven though this power wheelchair hasbeen tested and meets the requirements foringress of liquids, ALWAYS keep electricalconnections away from sources of dampness,this includes direct exposure to water, bodilyfluids, and incontinence. Electrical componentsdamaged by corrosion MUST be replacedimmediately. Wheelchairs that are used byincontinent users and/or are frequently exposedto water/liquids may require replacement ofelectrical components more frequently.

2.1.13 Electrical - Grounding Instructions

DANGER!Risk of Death or Serious InjuryElectric shock can cause death or serious injury– To avoid electric shock, inspect plug and cord forcuts and/or frayed wires. Replace cut cords or frayedwires immediately.

1143190-M~04 25

Page 26: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

DANGER!Risk of Death or Serious InjuryElectric shock can cause death or serious injury– DO NOT, under any circumstances, cut or removethe round grounding prong (i.e charger AC cableplug or the extension cord plug) from any plug usedwith or for Invacare products. Some devices areequipped with three-prong (grounding) plugs forprotection against possible shock hazards. Wherea two-prong wall receptacle is encountered, it isthe personal responsibility and obligation of thecustomer to contact a qualified electrician and havethe two-prong receptacle replaced with a properlygrounded three-prong wall receptacle in accordancewith the National Electrical Code. If you must usean extension cord, use only a three-wire extensioncord having the same or higher electrical rating asthe device being connected. In addition, Invacarehas placed RED/ORANGE warning tags on someequipment. DO NOT remove these tags.

2.1.14 Electrical - BatteriesThe warranty and performance specifications contained in this manualare based on the use of deep cycle gel sealed batteries. Invacarestrongly recommends their use as the power source for this unit.

Carefully read battery/battery charger information prior to installing,servicing or operating your wheelchair.

WARNING!Risk of Serious Injury or DamageDropping the battery can result in serious injury orproperty damage.– Batteries can weigh up to 52 lbs (23.6 kg). ALWAYSuse a battery lifting strap when lifting the battery. Itis the most reliable method of carrying a battery andpreventing serious injury.

2.1.15 Electrical - Charging Batteries

DANGER!Risk of Death or Serious InjuryUse of improper extension cord could cause electricshock or cause a fire resulting in death or serious injury.– When using an extension cord, use an extension cordhaving at least 16 AWG (American Wire Gauge) wireand the same or higher electrical rating as the devicebeing connected.

26 1143190-M~04

Page 27: TDX SP/SR Base Owner's Manual

Safety Handling

WARNING!– NEVER attempt to recharge the batteries by attachingcables directly to the battery terminals.

– DO NOT attempt to recharge the batteries andoperate the wheelchair at the same time.

– DO NOT operate wheelchair with extension cordattached to the AC cable.

– DO NOT attempt to recharge the batteries when thewheelchair has been exposed to any type of moisture.

– DO NOT attempt to recharge the batteries when thewheelchair is outside.

– DO NOT sit in the wheelchair while charging thebatteries.

– READ and CAREFULLY follow the manufacturer’sinstructions for each charger (supplied or purchased).If charging instructions are not supplied, consult aqualified technician for proper procedures.

– Ensure the pins of the extension cord plug are thesame number, size, and shape as those on the charger.

1143190-M~04 27

Page 28: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

2.1.16 Recycling Batteries

Lead acid batteries are almost entirely recyclable. Discarding thesebatteries in the trash is considered “improper disposal” and is illegalin most states. Old, used batteries are “hazardous material” andMUST be recycled through an approved agency. Contact your dealeror Invacare on proper disposal and recycling of your batteries.

2.1.17 Weight Training

WARNING!– Invacare DOES NOT recommend the use of itswheelchairs as a weight training apparatus. Invacarewheelchairs have NOT been designed or tested asa seat for any kind of weight training. If occupantuses said wheelchair as a weight training apparatus,Invacare shall NOT be liable for bodily injury and thewarranty is void.

2.1.18 Weight Capacity

WARNING!– Refer to Technical Data section in this manual todetermine the weight limit (total combined weight ofuser and any attachments) of your wheelchair model.

2.1.19 Electromagnetic Interference (EMI) FromRadio Wave Sources

Powered wheelchairs and motorized scooters (in this text, bothwill be referred to as powered wheelchairs) may be susceptibleto electromagnetic interference (EMI), which is interferingelectromagnetic energy (EM) emitted from sources such as radiostations, TV stations, amateur radio (HAM) transmitters, two wayradios, and cellular phones. The interference (from radio wavesources) can cause the powered wheelchair to release its brakes,move by itself, or move in unintended directions. It can alsopermanently damage the powered wheelchair's control system. Theintensity of the interfering EM energy can be measured in voltsper meter (V/m). Each powered wheelchair can resist EMI up to acertain intensity. This is called its "immunity level." The higher theimmunity level, the greater the protection. At this time, currenttechnology is capable of achieving at least a 20 V/m immunity level,which would provide useful protection from the more commonsources of radiated EMI.

There are a number of sources of relatively intense electromagneticfields in the everyday environment. Some of these sources areobvious and easy to avoid. Others are not apparent and exposureis unavoidable. However, we believe that by following the warningslisted below, your risk to EMI will be minimized.

The sources of radiated EMI can be broadly classified into three types:

28 1143190-M~04

Page 29: TDX SP/SR Base Owner's Manual

Safety Handling

1. Hand-held Portable transceivers (transmitters/receivers with theantenna mounted directly on the transmitting unit. Examplesinclude: citizens band (CB) radios, “walkie talkie”, security, fireand police transceivers, cellular telephones, and other personalcommunication devices).

Some cellular telephones and similar devices transmitsignals while they are ON, even when not being used.

2. Medium-range mobile transceivers, such as those used in policecars, fire trucks, ambulances and taxis. These usually have theantenna mounted on the outside of the vehicle.

3. Long-range transmitters and transceivers, such as commercialbroadcast transmitters (radio and TV broadcast antenna towers)and amateur (HAM) radios.

Other types of handheld devices, such as cordless phones,laptop computers, AM/FM radios, TV sets, CD players,cassette players, and small appliances, such as electricshavers and hair dryers, so far as we know, are not likely tocause EMI problems to your powered wheelchair.

2.1.20 Powered Wheelchair ElectromagneticInterference (EMI)

Because EM energy rapidly becomes more intense as one movescloser to the transmitting antenna (source), the EM fields fromhandheld radio wave sources (transceivers) are of special concern.It is possible to unintentionally bring high levels of EM energy veryclose to the powered wheelchair's control system while using thesedevices. This can affect powered wheelchair movement and braking.Therefore, the warnings listed below are recommended to preventpossible interference with the control system of the poweredwheelchair.

Electromagnetic interference (EMI) from sources such as radio andTV stations, amateur radio (HAM) transmitters, two-way radios,and cellular phones can affect powered wheelchairs and motorizedscooters.

FOLLOWING THE WARNINGS LISTED BELOW SHOULDREDUCE THE CHANCE OF UNINTENDED BRAKE RELEASE ORPOWERED WHEELCHAIR MOVEMENT WHICH COULD RESULTIN SERIOUS INJURY.

WARNING!– DO NOT operate handheld transceivers (transmittersreceivers), such as citizens band (CB) radios, or turnON personal communication devices, such as cellularphones, while the powered wheelchair is turned ON;

– Be aware of nearby transmitters, such as radio or TVstations, and try to avoid coming close to them;

– If unintended movement or brake release occurs, turnthe powered wheelchair OFF as soon as it is safe;

1143190-M~04 29

Page 30: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

WARNING!– Be aware that adding accessories or components, ormodifying the powered wheelchair, may make it moresusceptible to EMI (Note: There is no easy way toevaluate their effect on the overall immunity of thepowered wheelchair); and

– Report all incidents of unintended movement or brakerelease to the powered wheelchair manufacturer, andnote whether there is a source of EMI nearby.

WARNING!Important Information– 20 volts per meter (V/m) is a generally achievable anduseful immunity level against EMI (as of May 1994) (thehigher the level, the greater the protection);

– This device has been tested to a radiated immunitylevel of 20 volts per meter.

– The immunity level of the product is unknown.– Modification of any kind to the electronics of thispower wheelchair as manufactured by Invacare mayadversely affect the EMI immunity levels.

30 1143190-M~04

Page 31: TDX SP/SR Base Owner's Manual

Label Locations

3 Label Locations

3.1 All Wheelchairs

ITEM PARTNUMBER

DESCRIPTION

A 1183487 Serial Number Label

B 1167422 Controller Label

Label located under thecontroller

C 1035900 Transportation Label

D See Notes Weight Capacity Label(Base Only)

Label depends on model

1143190-M~04 31

Page 32: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

E 1167424 Replacing Motor/Gearbox Label

F 1104802 Push/Drive Label

G 1114826 and1114847

*22NF Battery WiringDiagram Labels

H 1114825 and1114848

*GP24 Battery WiringDiagram Labels

I 1118356 ** 22NF Battery Label

J 1118355 ** GP24 Battery Label

* Labels located under front shroud. Only one set of labelswill appear depending on chair model.

** Only one of the battery labels (22NF or GP24) will appeardepending on chair model.

32 1143190-M~04

Page 33: TDX SP/SR Base Owner's Manual

Label Locations

3.2 Wheelchairs with TRRO

Wheelchairs with TRRO

Wheelchairs without TRRO Wheelchairs with RunningLights

ITEM PARTNUMBER

DESCRIPTION

A 1082692 Compliance Label

B 1134848 Adjustment TRRO Label

Also on opposite side ofwheelchair.

C 1083199 Tie Down Point Label

Also on opposite side ofwheelchair.

D 1134840 Buckle Label

1143190-M~04 33

Page 34: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

ITEM PARTNUMBER

DESCRIPTION

E 1134811 Non Compliance Label

Auto style seat positioningstrap shown. This label isalso on the airline style seatpositioning strap.

F 1171793 Running Lights Label

34 1143190-M~04

Page 35: TDX SP/SR Base Owner's Manual

Technical Data

4 Technical Data

4.1 Specifications

4.1.1 Models

TDX SP TDXSPBASE, TDXSP,TDXSP-CG, TDXSP-MCG,TDXSP-CG-GT, TDXSP-GT,TDXSP-MCG-GT

TDX SR TDXSR, TDXSRV, TDXSR-CG,TDXSR-MCG

TDX SR HD TDXSR-HD, TDXSR-CG-HD,TDXSR-MCG-HD

4.1.2 Overall Dimensions

SP SR SR HD

Base Width (Without Joystick):

With two 22NF Batteries: 24 in(61 cm)

25.5 in(65 cm)

25.5 in(65 cm)

With two GP 24 Batteries 25.5 in(65 cm)

25.5 in(65 cm)

25.5 in(65 cm)

With three 22NF Batteries 25.5 in(65 cm)

25.5 in(65 cm)

25.5 in(65 cm)

Base Length (Without FrontRigging):

35.25 in (89 cm)

Overall Height -

SP SR SR HD

With ASBA Seat: 35.5 into 39.5 in (90 cmto 100 cm)

With Van Seat: 38 in (96 cm)

With Van Seat equipped withheadrest:

45 in (114 cm)

With Formula CG Tilt Only: 36.5 in to 40.5 in (93 cmto 103 cm)

With Elevating ASBA Seat: 35.5 to 41.5 in (35.5 cmto 105 cm)

Overall Length -

With Center Mount FrontRigging:

42.9 in (109 cm) @ 0°

Without Front Rigging: 35.25 in (89 cm)

All dimensions are ± .50 inches unless otherwise indicated.

4.1.3 Seat

SP SR SR HD

Tilt Angle Adjustment: Adjustable (0° - 10°)

1143190-M~04 35

Page 36: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

4.1.4 Wheels

Caster: 6 in x 2 in (15 cm x 5 cm) inSemi-pneumatic with Precision

Sealed Bearings

Drive Wheel/Tires: TDX SP – 14 in x 3 in (35 cm 8 cm) inFoam Filled or Pneumatic (Standard)

TDXS SR and SR HD — 14 x 3Foam Filled ONLY

Caster Forks: Two sided fork (Standard), Onesided fork (Optional)

Drive Axle: Non-adjustable

The size of tire is marked on the side wall of each drivetire. The caster tires do not have the tire size marked asthe caster tires are not serviceable. If new tire is needed,the entire caster wheel assembly MUST be replaced.

4.1.5 Axle

SP SR SR HD

Drive Axle: Non-adjustable

4.1.6 Battery

Battery Type

GP24 22NF

Number ofBatteries Needed

2 2

Manufacturer MK batteries MK batteries

Model p/n M24SLDGbatteries only

p/n M22NFSLDGbatteries only

Voltage 12 12

Capacity(Amp-hours) for5 hour rating

63 43.2

Only sealed non-spillable batteries that meet DOT CFR173.159 (d), IATA Packing Instructions 806, and IATAProvision A67 shall be installed in this wheelchair.

4.1.7 Footrests

SP SR SR HD

Footrest: Telescoping Front Rigging Supports, 2 in and4 in. long Pivot Slide Tube

36 1143190-M~04

Page 37: TDX SP/SR Base Owner's Manual

Technical Data

4.1.8 Weight

SP SR SR HD

Weight (Base Only) - - -

Without 22NFBatteries:

123 lbs (56Kg)

N/A N/A

With two 22NFBatteries:

221 lbs(100 Kg)

N/A N/A

Without GP24Batteries:

158 lbs (72Kg)

252 lbs(114 Kg)

252 lbs(114 Kg)

With (2) GP24Batteries:

260 lbs(118 Kg)

350 lbs(159 Kg)

350 lbs(159 Kg)

With Transport ReadyOption:

Add 10 lbs(4.5 Kg)

Add 10 lbs(4.5 Kg)

Add 10 lbs(4.5 Kg)

4.1.9 Weight Capacity Warnings

WARNING!Risk of Death or Serious InjuryExceeding the weight capacity of the wheelchair/seatingsystem could cause instability resulting in death orserious injury.– DO NOT exceed the weight capacity.

WARNING!Risk of Serious Injury or DeathFailure to observe this warning can result in seriousinjury or death.Loss of traction on ramps and inclines can occur fora variety of reasons including; water, ramp material,surface conditions, steepness or grade etc. Lighterweight users may be at an increased risk for loss oftraction.– As such, when using on ramps or inclines alwaysreduce speed and proceed with caution.

4.1.10 Weight Capacity Values

TDX SP

4 POLE HD 4 POLE

With ASBA Seat: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With ASBA Jr. Seat: Up to 165 lbs(75 Kg)

N/A

With Van Seat: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With Formula CG Seating: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With Elevating ASBA Seat: Up to 300 lbs(136 Kg)

N/A

1143190-M~04 37

Page 38: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

TDX SR TDX SR HD

Gearless Brushless

With ASBA Seat: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With ASBA Jr. Seat: N/A N/A

With Van Seat: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With Formula CG Seating: Up to 300 lbs(136 Kg)

Up to 400 lbs(181 Kg)

With Elevating ASBA Seat: Up to 300 lbs(136 Kg)

N/A

38 1143190-M~04

Page 39: TDX SP/SR Base Owner's Manual

Wheelchair Operation

5 Wheelchair Operation

5.1 Preparing the Joystick for Use

WARNING!Risk of Serious Injury or DamageAttaching hardware that is loosely secured could causeloss of stability resulting in serious injury or damage.– After ANY adjustments, repair or service and beforeuse, make sure that all attaching hardware is tightenedsecurely.

WARNING!– Set-up of the driver control is to be performed onlyby a qualified technician. The final adjustments ofthe driver control may affect other activities of thewheelchair. Damage to the equipment could occurunder these circumstances.

WARNING!Risk of Death, Serious Injury, or DamageImproperly connected joystick could cause loss of powerresulting in death, serious injury, or damage.– Ensure the joystick is securely connected to controller.

DANGER!Risk of Death, Serious Injury, or DamageMalfunctioning joystick could cause unintended/erraticmovement resulting in death, serious injury, or damage.– If unintended/erratic movement occurs, stop usingthe wheelchair immediately and contact a qualifiedtechnician.

The joystick is factory installed on the right side of thewheelchair. To reposition the joystick onto the left side ofthe wheelchair, refer to Repositioning the Joystick.

1. Turn the adjustment lock lever A to release the adjustment lockfrom joystick mounting tube B.

2. Slide joystick mounting tube to the desired position.3. Turn the adjustment lock lever to secure the adjustment lock

to the joystick mounting tube.

1143190-M~04 39

Page 40: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

5.2 Turning the Power On/Off

SPJ+ Joysticks CMPJ+ Joysticks

1. To turn the power On, perform one of the following steps:

Joystick Action

CMPJ+Move the On/Off switch BForward to the On position.

SPJ+ Press the On/Off button A.

2. Turning the power Off can be achieved by performing one ofthe following steps:

Joystick Action

CMPJ+Move the On/Off switch BBack to the Off position.

SPJ+ Press the On/Off button A.

5.3 Using the Joystick to Drive the WheelchairThe joystick is located on the joystick housing and provides smoothcontrol of speed and direction. It is equipped with 360 degrees ofmobility for ease of operation. The joystick is spring-loaded, andautomatically returns to the upright (neutral) position when released.Pushing the joystick in a given direction causes the wheelchair tomove in that direction.

The joystick has proportional drive control, meaning that the furtherit is pushed from the upright (neutral) position, the faster thewheelchair moves. The maximum speed, however, is limited by thesetting of the speed-control knob.

To slow the wheelchair to a stop, simply release the joystick. Thewheelchair has automatic speed and direction compensation tominimize corrections.

When first learning to drive, select a slow speed and try to drivethe wheelchair as slowly as possible by pushing the joystick slightlyforward. This exercise will help you learn to utilize the full potentialof the proportional control and allow you to start and stop smoothly.

To drive the wheelchair, perform the following:

1. Adjust speed control knob to the appropriate setting.2. Turn the power On. Refer to Turning the Power On/Off.3. Maneuver the joystick in the following manner:

40 1143190-M~04

Page 41: TDX SP/SR Base Owner's Manual

Wheelchair Operation

MOVEMENT ACTION

FORWARD A Push joystick forward,towards the front of thewheelchair.

REVERSE B Pull joystick back, towardsthe rear of the wheelchair.

Turn RIGHT C Move joystick toward theright side of the wheelchair.

Turn LEFT D Move joystick toward the leftside of the wheelchair.

STOP Release the joystick and thewheelchair will slow to a stop.

For specific information about the joystick installed onthe wheelchair, refer to SPJ+, MK6i SPJ+ w/PSS andMK6i SPJ+ w/ACC Joystick Switches and Indicators orCMPJ+ Joystick Switches and Indicators.

5.4 SPJ+™, MK6i™ SPJ+ w/PSS and MK6i SPJ+w/ACC Joystick Switches and Indicators

Y Additional input for powered seating switch.

Z Active (if programmed)

5.4.1 On/Off ButtonThe On/Off button A is located at the front of the joystick housing.It is used to turn the wheelchair On and Off.

5.4.2 SpeedometerThe speedometer B is used to show the maximum speed. Theright-most LED indicates current maximum speed setting. The

1143190-M~04 41

Page 42: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

bottom left GREEN LED G flashes to indicate that the joystick isin speed limit mode. Speed limit mode limits the drive speed to apre-programmed value, typically when the seat has been elevated andthe wheelchair is required to drive at 20% speed.

5.4.3 Speed Control ButtonsThe speed control buttons C [tortoise button ( ) and hare button

( )] are used to set and adjust the maximum speed.

1. To adjust the speed, perform one of the following:• Adjust Speed in 20% Increments (5 Speed Mode) -

Press the tortoise button ( ) or hare button ( ) todecrease/increase the speed in 20% increments. The largerbars in the speedometer will light.

• Adjust Speed in Smaller Increments (VSP Mode) - Performthe following steps:

a. Press and hold both the tortoise button ( ) and hare

button ( ) until the joystick beeps.b. Perform one of the following:

– Press the tortoise button ( ) or hare button ( )to decrease/increase the speed in 20% increments.The larger bars in the speedometer will light.

– Press and hold the tortoise button ( ) or hare

button ( ) to decrease/increase the speedin smaller increments. The smaller bars in thespeedometer will light.

5.4.4 JoystickThe joystick D has proportional drive control, meaning that thefurther the joystick is pushed from the upright (neutral) position, thefaster the wheelchair or seat moves. Your top speed, however, islimited by the programmed settings.

To slow the wheelchair to a stop, simply release the joystick. Thewheelchair has automatic speed and direction compensation tominimize corrections.

5.4.5 Charger/Programming InputThe charger/programming input E is located at the front ofthe joystick housing. This provides easy access for chargingthe wheelchair batteries. This port also serves as the RemoteProgrammer Communication connection. Driving is prevented whilethe system is charging.

5.4.6 Information Gauge DisplayThe information gauge display F is located on the front of thejoystick housing and provides the following information to the useron the status of the wheelchair:

1. Power is On.2. True state-of-battery-charge, including notification of when the

battery requires charging:• Green LEDs are lit, indicating well charged batteries.• Amber LEDs are lit, indicating batteries are moderately

charged. Recharge batteries before taking a long trip.• Red LEDs are lit, indicating batteries are running out of

charge. Recharge batteries as soon as possible.

The Information Gauge display also serves as a systemdiagnostic device when a fault is detected by the controlmodule. A specific number of flashes of the LEDs indicatethe type of fault detected.

Refer to Information Gauge Display Diagnostics for thediagnostic indications of the wheelchair status.

5.4.7 Service IndicatorThe AMBER service indicator ( ) will light when an error or faultoccurs.

42 1143190-M~04

Page 43: TDX SP/SR Base Owner's Manual

Wheelchair Operation

5.4.8 Mode ButtonThe mode button H is only present on SPJ+ w/ACC joystick

5.5 CMPJ+ Joystick, Switches and Indicators

5.5.1 On/Off - Drive Select Toggle Switch (CMPJ+Joystick)

The drive select toggle switch A is located on the left side, belowthe LCD. The drive select position is momentary, meaning that it willreturn to the neutral position after a selection is made.

This switch allows the operator to select the type of operationor performance which best suits a particular control need orsituation. The DRIVE 1 program uses performance values which areindependent of those used for the DRIVE 2 or 3 or 4 program. As anexample, an operator may have a control need for spasticity in themorning and a very different need in the afternoon. DRIVE 1 can beprogrammed for higher speeds and quicker response while DRIVE

2 can be programmed for slower speeds and less responsivenessor vise versa. The other two drive programs could be indoor andoutdoor versions of DRIVE 1 and DRIVE 2.

Selecting the Drive Mode

1. Move the toggle up and release. DRIVE 1 will appear on LCD.2. Move the toggle up and release again. DRIVE 2 will appear on

LCD.3. Move the toggle up and release again. DRIVE 3 will appear on

LCD.4. Move the toggle up and release again. DRIVE 4 will appear on

LCD.5. Move the toggle up and release one more time to select DRIVE 1.

5.5.2 Speed ControlThe speed control knob B is located on the side of the joystickhousing.

1. Rotate the knob clockwise (forward) to increase the speed ofthe wheelchair to the programmed max speed.

2. Rotate the knob counterclockwise (backward) to decrease thespeed of the wheelchair to the programmed max speed.

5.5.3 JoystickThe joystick C has proportional drive control, meaning that thefurther the joystick is pushed from the upright (neutral) position, thefaster the wheelchair or seat moves. Your top speed, however, islimited by the programmed settings.

To slow the wheelchair to a stop, simply release the joystick. Thewheelchair has automatic speed and direction compensation tominimize corrections.

5.5.4 Charger/Programming InputThe charger/programming input D is located at the front ofthe joystick housing. This provides easy access for charging

1143190-M~04 43

Page 44: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

the wheelchair batteries. This port also serves as the RemoteProgrammer Communication connection. Driving is prevented whilethe system is charging.

5.5.5 LCD Display ScreensThe LCD Display E is located in front of the joystick and providesinformation on the status of the wheelchair through a backlit display.The LCD display is readable in both bright sunlight and completedarkness.

Splash Screen

This screen is displayed at startup of the joystick for about 2 seconds.This screen displays the software version and date information.

After this screen, the joystick displays the Main Screen.

Main Screen

The callouts in this illustration correspond to the LCDDisplay chart only.

During normal operation, the active drive is displayed in the upperhalf of the LCD display. Battery charge level is shown in the BatteryGauge Display (BGD) located on the right side of the LCD display. Atfull charge, solid blocks fill in all ten segments between E (Empty) andF (Full). As the battery becomes discharged, the top most segmentswill progressively disappear until no segments appear between Eand F. At this level, the user should charge the batteries as soonas possible.

The lower half of the LCD display is the Information Center. TheInformation Center displays current data on the wheelchair.

44 1143190-M~04

Page 45: TDX SP/SR Base Owner's Manual

Wheelchair Operation

LCD DISPLAY

ITEM DESCRIPTION

This field shows the currently selected Drive’sName.

Available choices are as follows:

Color MPJ+

Drive1*

Drive2*

Drive3*

Drive4*

** NoDrive**

DRIVENAME —A

*Drive names can be customized. Actualdrive names may display differently.

** No Drive selected via the programmer

BatteryLevelIndicator— B

This symbol shows the Battery Level and will changedepending on the available battery power.

This indicator is shown on every screen.

StatusMessage— C

This area displays status or instructions.

Clock —D

Displays current time.

StatusIndicator— E

The status indicator will show a “Warning”(exclamation point inside a triangle) indicator whenthe chair has a condition that requires attention.

The status indicator will show a “STOP” sign whena serious condition exists. The chair will not beallowed to operate.

The status indicator shows an Attendant Icon if theattendant’s override switch is active.

Modes— F

The dotted-box shows the area that contains theavailable “modes” in the currently selected drive. Themodes are programmed for each drive and are basedupon the configuration of the chair.

These modes are highlighted when the Mode is active.The operator changes modes by pressing the ModeSelect Switch.

The available modes are as follows:

to

Digital 3 Speed1 - 3

RIMMode

NoDriving

AutomaticPositioning

PoweredSeating

1143190-M~04 45

Page 46: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

4-Switch Level1(L1, L1 Latched)

4-Switch Level2(L2, L2 Latched)

to

ECU Output Activated

ASM 2 Infrared Mouse Mouse B

Driving Screen

This screen is shown when the operator issues a drive command andthe Drive Icon on the main screen was highlighted.

The Drive’s name, warning/info message, status icon andbattery indicator are displayed on this screen.

5.5.6 User SettingsDepress the mode button of the CMPJ+ joystick for 10 seconds andthe User Settings screen will appear with three choices shown. Movethe joystick forward or reverse to scroll through the list. Move thejoystick to the right to select a user setting.

User Settings

Set Date and Time Battery Voltage

Fault Codes Connected Devices

46 1143190-M~04

Page 47: TDX SP/SR Base Owner's Manual

Wheelchair Operation

User Settings

Set Dateand Time

SET DATE AND TIME - Sets the clock on theCMPJ+ joystick. Adds date and time stamp toerror codes.

• Move the joystick Up or Down to changethe highlighted value (hour, minute, AM/PM,month, day, year)

• Move the joystick Right or Left to select avalue or the Set icon.

• Highlight the Set icon and move the joystickforward to enter new date and time.

BatteryVoltage

BATTERY VOLTAGE - Displays current batteryvoltage. This is a diagnostic test a user canperform prior to a service call.

Fault Code FAULT CODES - Displays time and date stampedfault codes. This information can be helpful to aprovider prior to making a service call.

ConnectedDevices

CONNECTED DEVICES - Displays deviceconnections.

Connected Devices Screen

This screen is displayed if the Mode Select switch is held active forabout 10 seconds. This screen shows an icon that represents anyadditional devices that are connected to the chair

ICON DESCRIPTION ICON DESCRIPTION

Intelligent TiltActuator

RIM Control

Intelligent ReclineActuator

ECU 1/2 and ECU3/4

Intelligent CenterLeg Actuator

ProportionalAttendant Control

Elevate Actuator Compact Joystick

Generic TiltActuator

Sip and Puff Control

Generic ReclineActuator

Digital AttendantControl

Generic LegActuator

Micro ExtremityControl

Generic Right LegActuator

Peachtree Control

Generic Left LegActuator

ASL Digital Control

1143190-M~04 47

Page 48: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

Intelligent CG Tilt Generic AnalogControl

Shark PowerModule (SPM)Actuator

This is displayedif the controllersupports G-Trac

SANODE orSingle ActuatorControl Interface

Mouse Only

4–way Switch Box IR/Mouse

Multiple ActuatorControl Box

5.5.7 CMPJ+ Joystick - Programmable Mono Ports 1and 2 with External Mode Switch

The programmable mono port with external mode switch input islocated at the rear of the joystick on the left side. The programmablemono port input offers the choice of three options:

• Remote drive select• Remote stop/mode (reset) input• Single actuator input

The single switch functions operate through mono port 1. Anoptional y-cable allows a second programmable function throughmono port 2.

Remote Stop Switch

he remote reset switch may be used to stop the wheelchair if thewheelchair is in motion.

The remote reset switch also functions in the same way as thejoystick mode switch when the wheelchair is not in motion. Refer toMode Switch (CMPJ+ Joystick).

5.5.8 Remote On/Off SwitchThe remote On/Off switch input is located at the rear of the joystickon the right side and allows the power switch to be operated by anability switch (normally open momentary switch with mono plug).To use the remote On/Off feature, the Drive Select/On/Off switchmust be in the On position. Each activation of the ability switch willalternately turn the joystick On or Off.

5.5.9 Mode Switch (CMPJ+ Joystick)The mode switch [CMPJ+ Joystick G] is used to select the operatingmode for the wheelchair. The mode switch is located on the joystick.A mode switch is needed whenever any of the following operatingmodes are programmed:

*In these modes, Standby Select allows the reset switch tobe bypassed for users unable to activate the switch.

• Environmental Controls (ECU 1, ECU 2, ECU 3, ECU 4)*• 3 Speed Mode in Digital 3 Speed (Slow, Medium, Full)• Sleep Mode• RIM Mode*• Remote Drive Selection Mode*• Tilt/Recline Mode*• Information Center Display Selection (does not require Reset

activation at power up)

If any of the above modes are selected, the control will requireactivation of the switch immediately after the power switch is turnedOn in order to enter the drive mode. The second line of the LCDwill display - PRESS RESET.

48 1143190-M~04

Page 49: TDX SP/SR Base Owner's Manual

Wheelchair Operation

5.5.10 Memory Card SlotThe memory card slot is used with the basic or professional memorycard for saving or reading wheelchair parameters.

5.6 When to Charge BatteriesKeep Batteries charged. When possible, DO NOT allowbattery charge to empty.

If battery charge becomes so low that no battery indicatorsare lit, allow the batteries to charge overnight.

5.6.1 SPJ+, SPJ+ w/PSS and SPJ+ w/ACC JoysticksThe Information Gauge Display located on the front of the joystickhousing, it provides the state-of-battery charge, including notificationof when the battery requires charging. It also provides the followinginformation to the user on the status of the wheelchair:

• Green LEDs are lit, indicating well charged batteries.• Amber LEDs are lit, indicating batteries are moderately charged.

Recharge batteries before taking a long trip.• Red LEDs are lit, indicating batteries are running out of charge.

Recharge batteries as soon as possible.

5.6.2 CMPJ+ Joystick

The far right side of the display screenA is the Battery Gauge DisplayB. It provides information on the remaining charge in the batteries.

At full charge, solid blocks fill in battery gauge. As the batterybecomes discharged, the segments will progressively disappearstarting on the right and moving towards the left a bar at a timeuntil no segments appear. At this level the user should charge thebatteries as soon as possible.

1143190-M~04 49

Page 50: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

5.7 Charging Batteries

WARNING!– Never attempt to recharge the batteries by attachingcables directly to the battery terminals or clamps.Always use the recharging plug located on the frontof the joystick.

– DO NOT sit in the wheelchair while charging thebatteries.

– DO NOT attempt to recharge the batteries andoperate the power wheelchair at the same time.

– During use and charging, unsealed batteries willvent hydrogen gas which is explosive in the rightconcentration with air.

New batteries MUST be fully charged prior to initial useof the wheelchair.

As a general rule, batteries should be recharged daily toassure the longest possible life and minimize the requiredcharging time. Plan to recharge the batteries when it isanticipated the wheelchair will not be used for a long periodof time.

The range per battery charge using recommended batteries shouldbe approximately 5 to 9 hours of typical operation. Extensive use oninclines may substantially reduce per charge mileage.

5.7.1 Description and Use of Battery ChargersThe charger automatically reduces the charge from an initially highrate to a zero reading at a fully charged condition. If left unattended,the charger should automatically shut-off when full charge is obtainedor enter a trickle charge mode to maintain the batteries dependingon charger model.

There are some basic concepts which will help you understand thisautomatic process. They are:

Once the charger has been connected to the wheelchair and walloutlet and, if necessary, the charger has been turned on, the batterycharger indicator lights will flash and light to show the battery chargerstatus and condition of batteries to be charged. Refer to owner’smanual shipped with battery charger.

WARNING!– NEVER leave the charger unattended when thebreaker has tripped. A fault condition exists. Unplugand discontinue using immediately. Contact anInvacare dealer.

If performing the charging procedures, READ andCAREFULLY follow the individual instructions for eachcharger (supplied or purchased).

If charging instructions are not supplied, consult a qualifiedservice technician for proper procedures.

Required Items

TOOL QTY COMMENTSs

Battery Charger 1 Supplied

1. Attach the battery charger connector to the charger port onthe joystick.

2. Plug the charger’s AC power cord, or extension, into thegrounded 120 VAC wall outlet.

3. Wait until charging is complete.

50 1143190-M~04

Page 51: TDX SP/SR Base Owner's Manual

Wheelchair Operation

Allow eight hours for normal charging. Larger batteries(greater than 55 ampere-hours) or severely dischargedbatteries may require up to sixteen hours to be properlycharged and equalized.

It is advantageous to recharge frequently rather than onlywhen necessary. In fact, a battery’s life is extended if thecharge level is maintained well above a low condition.

If the batteries need to be charged more often or takelonger to charge than normal, they may need to be replaced.Contact an Invacare dealer for service.

SPJ+, SPJ+ w/PSSand SPJ+ w/ACC

Joysticks

CMPJ+ Joystick Display

A — Charger Programming Port

Located on Backof Joystick

Located on Frontof Joystick

Located on Backof Display

5.8 Disengaging/Engaging the Motor LockLevers

WARNING!– DO NOT engage or disengage motor locks until thepower is in the OFF position.

Motor lock A disengagement/engagement allowsfree-wheeling or joystick controlled operation.Free-wheeling allows an assistant to maneuver thewheelchair without power.

Motor lock levers are located between the rear casterassembly and drive wheel on both sides of the wheelchair.

1. Perform one of the following as if viewing the motors frombehind the wheelchair (Detail “A”):• Disengage (PUSH) - Move the motor lock levers UP to

disengage the motors and push the wheelchair.• Engage (DRIVE) - Move the motor lock levers DOWN to

engage the motors and drive the wheelchair.

1143190-M~04 51

Page 52: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

5.9 Disengaging/Engaging the Motor LockLevers - TDX SR

Engaged Position Disengaged Position

WARNING!– DO NOT engage or disengage motor locks until thepower is in the OFF position.

Motor lock disengagement/engagement allows free-wheelingor joystick controlled operation. Free-wheeling allows anassistant to maneuver the wheelchair without power.

Motor lock levers are located between the rear casterassembly and drive wheel on both sides of the wheelchair.

1. Perform one of the following:

• Disengage (PUSH) - Pull motor lock levers up.• Engage (DRIVE) - Push motor lock levers down.

5.10 Disengaging/Engaging the Wheel locks

WARNING!– DO NOT use the wheel locks when the wheelchairpower is on and the clutches are engaged - otherwisedamage to the wheelchair may result.

Use the wheel locks whenever the clutches are disengagedand the wheelchair is being pushed.

5.10.1 Engaging

1. Push handle forward away from tire to engage wheel lock.2. Repeat STEP 1 for opposite wheel.

5.10.2 Disengaging

1. Pull handle back toward tire to disengage wheel lock.2. Repeat STEP 1 for opposite wheel.

52 1143190-M~04

Page 53: TDX SP/SR Base Owner's Manual

Wheelchair Operation

5.11 Disengaging/Engaging the Wheel Hubs

Disengaged

DC

B

A

Engaged

F

E

Disengaging (Free Wheel)

If the pins on the engagement knob are not in the free wheeldetents, the engagement knobs can engage the motorsunexpectedly while the wheelchair is being pushed.

1. Pull out on engagement knob A and rotate approximately 1/6turn until the pins B of the engagement knob fall into the freewheel detents C of the wheel hub D.

2. Repeat STEP 1 for opposite wheel.

Engaging

1. Pull engagement knob out E and rotate approximately 1/6 turnuntil the engagement knob pins sink into the holes in the wheelhub F.

2. Repeat STEP 1 for opposite wheel.3. Gently rock the wheelchair until the engagement knob snaps

into place and fully engage the wheel hub.

1143190-M~04 53

Page 54: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

6 Transport Ready Option(TRRO)

6.1 About Transport Ready Packages

WARNING!– This section applies only to wheelchairs equipped withTRRO (Transport Ready Option).

– Contact Invacare Corporation (800-333-6900) withany questions about using this wheelchair for seatingin a motor vehicle.

– When feasible, wheelchair occupants should transferinto the vehicle seat and use the OEM (OriginalEquipment Manufacturer) vehicle-installed restraintsystem.

– This wheelchair has been dynamically tested in aforward-facing mode with the specified crash testdummy restrained by BOTH pelvic and upper-torsobelt(s) (shoulder belts), and that BOTH pelvic andupper torso belt(s) should be used to reduce thepossibility of head and chest impacts with vehiclecomponents.

– Use ONLY Wheelchair Tie-down and OccupantRestraint Systems (WTORS) which meet therequirements of the SAE (Society of AutomotiveEngineers) J2249 Recommended Practice during travelin a motor vehicle.

– This wheelchair has been tested for seating in a motorvehicle with the factory installed seating system only.

– This wheelchair MUST be in a forward facing positionduring travel in a motor vehicle.

– This wheelchair is equipped, and has been dynamicallytested to rely on WHEELCHAIR-ANCHORED pelvic

belts. If desired, vehicle-anchored pelvic belts may beused.

WARNING!– IT IS STRONGLY RECOMMENDED THAT BOTHPELVIC AND UPPER-TORSO BELT(S) BE USED TOREDUCE THE RISK OF INJURY.

– To reduce the potential of injury to vehicle occupants,wheelchair-mounted accessories, including but notlimited to IV poles, trays, respiratory equipment,backpacks, and other personal items should beremoved and secured separately.

– Postural supports, positioning devices, and/orstrap(s) should not be relied on for occupantrestraint. These items may be used in addition to thewheelchair-anchored or vehicle-anchored belts.

– Seat angle is factory set at time of shipment.Adjustments to the wheelchair may void ANSI/RESNAWC/Vol. 1– Section 19 compliance. To maintaincompliance, refer to wheelchair service manual beforemaking any adjustments.

– DO NOT alter or substitute wheelchair frame parts,components, or seating systems.

– A sudden stop and/or collision may structurallydamage your wheelchair. Wheelchairs involved insuch incidents should be replaced.

– Spill proof batteries, such as “gel sealed”, should beinstalled on wheelchairs to be used during travel in amotor vehicle.

– Transport ready packages are not retrofittable toexisting models and are not field serviceable.

54 1143190-M~04

Page 55: TDX SP/SR Base Owner's Manual

Transport Ready Option(TRRO)

ANSI = American National Standards Institute, RESNA=Rehabilitation Engineering and Assistive Technology Societyof North America.

TRRO includes four factory-installed transport brackets and awheelchair anchored pelvic belt. TRRO has been crash-tested inaccordance with ANSI/RESNA WC Vol 1 Section 19 Frontal ImpactTest requirements for wheelchairs with a 130 lb (59 kg) crash testdummy, which corresponds to a person with a weight of 125 lb (57kg) to 165 lb (75 kg) for Junior seat sizes or a 168 lb (76 kg) crashdummy, which corresponds to a person with a weight of 165 lb (75kg) to 300 lbs (136 kg) for Adult seat sizes.

As of this date, the Department of Transportation has not approvedany tie-down systems for transportation of a user while in awheelchair, in a moving vehicle of any type. It is Invacare’s positionthat users of wheelchairs should be transferred into appropriateseating in vehicles for transportation and use be made of therestraints made available by the auto industry. Invacare cannot anddoes not recommend any wheelchair transportation system.

6.2 Compliance InformationThis wheelchair conforms with the requirements of the ANSI/RESNAWC/Vol. 1 - Section 19 (Frontal Impact Test)

ANSI = American National Standards Institute, RESNA=Rehabilitation Engineering and Assistive Technology Societyof North America.

This wheelchair has been dynamically tested in a forward-facingmode with the specified crash test dummy, which corresponds to aperson with a weight of 114 lbs (52 kg) - 209 lbs (95 kg), restrainedby Both pelvic and shoulder belts in accordance with ANSI/RESNAWC/Vol 1 – Section 19. Both pelvic and upper torso belts should

be used to reduce the possibility of head and chest impacts withvehicle components.

6.3 Specifications

WEIGHT LIMITMODEL MOTOR

Adult Junior

TDX SP HD Up to 400 lbs(181 kg)

N/A

TDX SP Up to 300 lbs(136 kg)

Up to 150 lbs(68 kg)

TDX SR Up to 300 lbs(136 kg)

Up to 150 lbs(68 kg)

TDX SR HD

4 Pole HD

Up to 400 lbs(181 kg)

N/A

1143190-M~04 55

Page 56: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

6.4 Positioning the Wheelchair in the Vehicle

WARNING!– This wheelchair MUST be in a forward facing positionduring travel in a motor vehicle.

– The recommended clear zones for wheelchair seatedoccupants restrained by both pelvic and upper torsobelt(s) and only by a pelvic belt are shown in thediagrams and described below.

– Frontal Clear Zones (FCZ) need to be LARGER whenupper torso belt(s) are NOT used.

– The rear clear zone of 16 inches (41 cm) is measuredfrom the rearmost point on an occupant’s head.

– The frontal clear zone is measured from the frontmostpoint on an occupant’s head and is 26 inches (66 cm)with pelvic and upper-torso belt(s) and 37 inches (94cm) with ONLY a pelvic belt.

– The frontal clear zone may not be achievable forwheelchair-seated drivers.

– The estimated seated height (HHT) from the groundor floor to the top of the wheelchair-seated occupant’shead ranges from approximately 47 inches (119 cm)for a small adult female to about 61 inches (155 cm)for a tall adult male

6.5 Securement Points

ITEM DESCRIPTION

A TIE DOWN BRACKETS

56 1143190-M~04

Page 57: TDX SP/SR Base Owner's Manual

Transport Ready Option(TRRO)

6.6 Securing the WheelchairThis wheelchair is to be used only with Wheelchair Tie-down andOccupant Restraint Systems (WTORS) that have been installed inaccordance with the manufacturer's instructions and SAE J2249.

A copy of SAE J2249 Wheelchair Tie-down and OccupantRestraint Systems (WTORS) for use in Motor Vehicles canbe obtained from: SAE International, 400 CommonwealthDrive, Warrendale, PA 15096-0001, (877) 606-7232 or(724) 776-4970.

Attach WTORS to the tie-down brackets in accordance with themanufacturer's instructions and SAE J2249.

6.7 Securing the Occupant

6.7.1 Wheelchair-Anchored Belts

WARNING!– The pelvic belt that is provided by Invacare has beentested for use in a motor vehicle on this wheelchaironly. Do not replace the pelvic belt with a differentstyle pelvic belt.

SP JUNIOR SEATS ONLY

1143190-M~04 57

Page 58: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

The wheelchair has been provided with a pelvic belt which meets therequirements of ANSI/RESNA WC/19.

The pelvic belt provided by Invacare has been designed toaccommodate use on either side of the vehicle. If necessary, followthe instructions below to reverse the orientation of the pelvic belt toaccommodate the vehicle-anchored upper torso belt.

1. Install the pelvic belt pin A into slotB in the pelvic belt bracketC. Pull upwards until it snaps into place.

Both ends of the pelvic belt D have a pin which is usedto secure the vehicle-anchored upper torso belt.

2. Repeat step 1 for the opposite pelvic belt bracket.3. Install the vehicle-anchored upper torso belt onto the pin

Elocated at either end of the pelvic belt.

6.7.2 Vehicle-Anchored Belts

Rear view of wheelchair and human surrogate secured ontest platform A and tilted to 45°.

With regard to accommodating the use and fit of vehicle-anchoredbelts, this wheelchair has an overall rating of:

• TDX SP/TDX SR Adult/TDX SR Junior - “A”• TDX SP Junior - “B”

This rating is scored as follows:

RATING DESCRIPTION

A Excellent

B Good

58 1143190-M~04

Page 59: TDX SP/SR Base Owner's Manual

Transport Ready Option(TRRO)

RATING DESCRIPTION

C Fair

D Poor

The test for Lateral Stability Displacement for Point Pis shown in:

• TDX SP with Two 22NF Batteries -– TDX SP Adult - 0.53 in (13.4 mm)– TDX SP Junior - 0.57 in (14.4 mm)

• TDX SP/SR with Two GP24 Batteries -– TDX SP/SR Adult - 0.54 in (13.7 mm)– TDX SP Junior - 0.51 in (12.95 mm)– TDXR Junior - 0.29 in (7.46 mm)

6.7.3 Seating System

WARNING!– This wheelchair has been tested for seating in a motorvehicle with the factory installed seating system only.

– When feasible, wheelchair occupants should transferinto the vehicle seat and use the OEM (OriginalEquipment Manufacturer) vehicle-installed restraintsystem

Ensure that the factory installed seating system is secured to thewheelchair frame before operation. Refer to the seating system usermanual.

6.7.4 Positioning Belts

Preferred Zone

Optional Zone

1143190-M~04 59

Page 60: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

WARNING!– The angle of the pelvic belt should be within thepreferred zone of 45 to 75 degrees to the horizontalOR within the optional zone of 30 to 45 degrees tothe horizontal.

– Steeper side-view pelvic belt angles are especiallyimportant if the pelvic belt is intended to be used forpostural support in addition to occupant restraint in afrontal crash. Steeper angles will reduce the tendencyfor a vertical gap to develop between the user andthe belt due to compliance of seat cushions and beltmovement, thereby reducing the tendency for theuser to slip under the belt and for the belt to ride upon the soft abdomen during normal use

– Steeper belt angles also reduce the tendency forupper-torso belts to pull the pelvic belt onto theabdomen during frontal impact loading.

DO position belts INSIDE ofarmrests, wheels, etc.

DO NOT position beltsOUTSIDE of armrest,

wheels, etc.

1. The pelvic belt should be worn low across the front of the pelvis.2. Position the upper torso belt(s) over the shoulders.

3. The belt(s) should not be held away from the body by wheelchaircomponents or parts, including but not limited to wheelchairarmrests or wheels.

4. Ensure the belt(s) are not be twisted.5. Adjust belts as firmly as possible, being mindful of user comfort.

60 1143190-M~04

Page 61: TDX SP/SR Base Owner's Manual

Setup and Maintenance

7 Setup and Maintenance

7.1 Setup/Delivery InspectionSetup/delivery inspection should be performed by dealer attime of delivery/set up.

Initial adjustments should be made to suit your personalbody structure needs and preference. Thereafter weekly,monthly and periodic inspections should be performed byuser/attendant between the six month service inspections.

Every six months, and as necessary, take your wheelchair toa qualified technician for a thorough inspection and servicing.

q Check all parts for shipping damage. In case of damage, DONOT use.

q Ensure wheelchair rolls straight (no excessive drag or pull toone side).

q Ensure clothing guards are secure.q Ensure arms are secure but easy to release and adjustment

levers engage properly.q Ensure adjustable height arms operate and lock securely.q Ensure axle nut or bolt and wheel mounting nuts are secure

on drive wheels.q Ensure caster/anti-tipper wheels are free of debris, and all

mounting hardware is secure and not damaged/missing.q Check that cables are routed and secured properly to ensure

that cables do NOT become entangled and damaged duringnormal operation of seating system.

q Ensure proper operation of powered functions (Example: drive,seating and legrests).

7.2 User/Attendant Inspection ChecklistsEvery six months, and as necessary, take your wheelchair toa qualified technician for a thorough inspection and servicing.

Weekly, monthly, and periodic inspections should beperformed by user/attendant between the six month serviceinspections.

Regular cleaning will reveal loose or worn parts and enhancethe smooth operation of your wheelchair. To operateproperly and safely, your wheelchair MUST be cared for justlike any other vehicle. Routine maintenance will extend thelife and efficiency of your wheelchair.

CAUTION!– As with any vehicle, the wheels and tires should bechecked periodically for cracks and wear and shouldbe replaced.

7.2.1 Inspect/Adjust Weeklyq Ensure that the casters are free of debris.q Inspect tires for flat spots and wear.q Inspect all fasteners.q Inspect TRBKTS fasteners and hardware.q Ensure proper operation of powered functions (Example: drive,

seating and legrests).

7.2.2 Inspect/Adjust Monthlyq Clean upholstery and armrests.q Clean dirt and lint from axles.q Clean dirt and lint from bearings.q Ensure that the casters are free of debris.

1143190-M~04 61

Page 62: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

q Inspect seat positioning strap for any signs of wear. Ensurebuckle latches. Verify hardware that attaches strap to frame issecure and undamaged. Replace if necessary.

7.2.3 Inspect/Adjust Periodically• Ensure wheelchair rolls straight (no excessive drag or pull to

one side).• Inspect all operator (user/attendant) adjustable fasteners

including the back pan, back cane and angle adjustment fasteners,and the arm support, flip back and height adjustment fasteners.Ensure fasteners are securely tightened.

• Inspect TRBKTS fasteners and hardware.• Ensure clothing guards are secure.• Ensure arms are secure but easy to release and adjustment

levers engage properly.• Ensure adjustable height arms operate and lock securely.• Ensure upholstery does not have any rips or tears.• Armrest pad sits flush against arm tube.• Ensure that the casters are free of debris.• Inspect foam handgrips for damage. If damaged, have them

replaced by a qualified technician.• Check center mount front riggings for loose fasteners. Replace

/tighten if necessary.• Check that all labels are present and legible. Replace if necessary.

7.3 Service InspectionEvery six months take your wheelchair to a qualifiedtechnician for a thorough inspection and servicing.

Service inspections MUST be performed by a qualifiedtechnician.

WARNING!– After ANY adjustments, repair or service and beforeuse, make sure that all attaching hardware is tightenedsecurely - otherwise injury or damage may result.

CAUTION!– As with any vehicle, the wheels and tires should bechecked periodically for cracks and wear and shouldbe replaced.

The following are recommended items to inspect during regularservice inspections performed by a qualified technician. Actual itemsto be inspected during the service inspection may vary accordingto the specific wheelchair:

7.3.1 Six Month Inspection

DANGER!Risk of Death, Serious Injury, or DamageFailure to complete the inspection of the criticalcomponents listed below could result in death or seriousinjury.– Inspect stability control components which couldinclude anti-dive spring, anti-dive cylinder, ratchetinggears, or end stops to ensure proper operation.

– Inspect drive axle nut, locking tab, wheel fasteners orquick release to ensure drive wheel is secure

q Inspect stability lock cylinders, front and rear swing arms toensure proper operation.

q Ensure adjustable height arms operate and lock securely.q Ensure arms are secure but easy to release and adjustment

levers engage properly.

62 1143190-M~04

Page 63: TDX SP/SR Base Owner's Manual

Setup and Maintenance

q Inspect seat positioning strap for any signs of wear. Ensurebuckle latches. Verify hardware that attaches strap to frame issecure and undamaged. Replace if necessary.

q Ensure axle nut or bolt and wheel mounting nuts are secureon drive wheels.

q Inspect tires for flat spots and wear.q Loosen/tighten caster locknut if wheel wobbles noticeably or

binds to a stop.q Ensure all caster/wheel/fork/headtube fasteners are secure and

not damaged/missing.q Check center mount front riggings for loose fasteners. Replace

/tighten if necessary.q Cables shall be inspected periodically to ensure that they

are routed and secured properly. Periodic inspection isrecommended as it may reveal loose and/or damaged cables.Re-secure all loose cables and replace by following therecommendations outlined in the Power Wheelchair WiringGuide, p/n 1167603.

q Ensure proper operation of powered functions (drive, seating,legrests, etc.).

q Inspect motor brushes and gearbox coupling.q Inspect electrical components for signs of corrosion. Replace if

corroded or damaged.q Inspect battery terminals for loose cable connection. Tighten if

necessary.q Ensure swingarm stops are in place and not deteriorated or

damaged. Replace if necessary.q Clean upholstery and armrests.q Clean dirt and lint from axles.q Clean dirt and lint from bearings.q Check that all labels are present and legible. Replace if necessary.q Ensure clothing guards are secure.q Ensure upholstery does not have any rips or tears.

q Ensure armrest pad sits flush against arm tube.q Ensure wheelchair rolls straight (no excessive drag or pull to

one side).q Ensure that the casters are free of debris.q Inspect all fasteners including the back pan, back cane and angle

adjustment fasteners, and the arm support, flip back and heightadjustment fasteners. Ensure fasteners are securely tightened.

q Inspect TRBKTS fasteners and hardware.q Inspect foam handgrips for damage. If damaged, have them

replaced by a qualified technician.

7.3.2 Inspect/Adjust Every 18 MonthsReplace motor brushes and gearbox coupling.

7.3.3 Inspect/Adjust Every 2 YearsThe stability locking cylinders MUST be replaced every two years.

7.4 Cleaning

CAUTION!Risk of DamageSpraying the wheelchair with water or any type of liquidmay permanently damage the electronics.– NEVER spray the wheelchair with any type of wateror liquid.

Regular cleaning will reveal loose or worn parts and enhancethe smooth operation of your wheelchair. To operateproperly and safely, your wheelchair must be cared for justlike any other vehicle.

For upholstery that is severely stained or surface finish thatis badly damaged, contact Invacare for further information.

1143190-M~04 63

Page 64: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

7.4.1 Cleaning Upholstery, Cloth, VinylLukewarm water and a mild non-abrasive soap should be used toclean the upholstery. Wipe off surface with dry cloth. Repeat asnecessary to remove persistent stains.

If necessary, remove cover to aid in cleaning.

7.4.2 Cleaning Metal SurfacesHot water and a mild detergent on soft cloth should be used forcleaning metal surfaces. Wipe down with damp cloth. Dry surfaceby wiping down with dry cloth.

Car polish and soft wax can be used to remove abrasions and restoregloss (Follow manufacturer’s instructions).

7.4.3 Cleaning Plastic SurfacesPlastic surfaces should be cleaned with soft cloth, mild detergent, andhot water. Rinse surface with clean water. Dry surface with softcloth. Solvents or kitchen cleaners MUST not be used on plasticsurfaces.

7.5 Removing/Installing the Shrouds

CAUTION!– Place the wheelchair in a well ventilated area wherework can be performed without risking damage tocarpeting or floor covering.

7.5.1 Removing the Rear Shroud

1. Verify the joystick On/Off switch is in the Off position.2. Remove the three mounting screw A securing the rear shroud

B to the wheelchair.3. Remove the rear shroud from the wheelchair D.

7.5.2 Installing the Rear Shroud

1. Install the rear shroud B and secure in place with mountingscrew(s) A.

New Batteries MUST be fully charged before using,otherwise the life of the battery(ies) will be reduced.

7.5.3 Removing/Installing the Front Shroud/BatteryRetention Bracket

Removing64 1143190-M~04

Page 65: TDX SP/SR Base Owner's Manual

Setup and Maintenance

The front shroud/battery retention bracket C is removed from andinstalled onto the wheelchair frame D as a single unit.

Front shroud/battery retention bracket C mounts on hooks Elocated on the wheelchair frame D.

Have the following tools available: 1/4 inch Allen Wrench,7/16 inch Box Wrench.

1. Remove the mounting screws F securing the frontshroud/battery retention bracket to the wheelchair frame D.

2. Lift up to unhook the front shroud/battery retention bracketfrom the base frame and remove.

Installing

CAUTION!– Wheelchairs with TRRO or TRBKTS Only - Batteryretention brackets MUST be installed at all times.Otherwise, the wheelchair will not be WC/19compliant.

When performing STEP 1, ensure that the tabs G located onthe sides of the front shroud/battery retention bracket Care positioned on the hooks E located on the front of thewheelchair frame D.

1. Reinstall the front shroud/battery retention bracket onto frontof wheelchair frame.

2. Secure the front shroud/battery retention bracket C to thewheelchair frame D with two mounting screws F. Securelytighten.

3. Gently, pull on the front shroud to ensure the mounting screwsare fully engaged into the battery box.

4. Wheelchairs with Footboards Only: Using the mounting screwH and washer I, secure the footboard support J to thewheelchair frame.

7.6 Batteries

WARNING!– Invacare strongly recommends that battery installationand battery replacement always be done by a qualifiedtechnician.

– The use of rubber gloves is recommended whenworking with batteries.

– After ANY adjustments, repair or service and beforeuse, make sure all attaching hardware is tightenedsecurely - otherwise injury or damage may result.

– When lifting batteries, use proper lifting techniques(lift with your legs) to avoid injury. Refer to TechnicalData for battery weight.

– DO NOT tip the batteries. Keep the batteries in anupright position.

– When tightening the clamps, always use a box wrench.Pliers will “round off” the nuts. NEVER wiggle thebattery terminal(s)/post(s) when tightening. Thebattery may become damaged.

– Unless otherwise indicated, make sure power tothe wheelchair is OFF before performing theseprocedures.

1143190-M~04 65

Page 66: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

DANGER!Risk of Death or Serious InjuryFailure to observe these warnings can cause an electricalshort resulting in death, serious injury, or damage tothe electrical system.– The POSITIVE (+) RED battery cable MUST connectto the POSITIVE (+) battery terminal(s)/post(s).

– The NEGATIVE (-) BLACK battery cableMUST connect to the NEGATIVE (-) batteryterminal(s)/post(s).

– NEVER allow any of your tools and/or battery cable(s)to contact BOTH battery post(s) at the same time.An electrical short may occur and serious injury ordamage may occur.

– Install protective caps on positive and negative batteryterminals.

– Replace cable(s) immediately if cable(s) insulationbecomes damaged.

– DO NOT remove fuse or mounting hardware fromPOSITIVE (+) red battery cable mounting screw.

If there is battery acid in the bottom of the battery box oron the sides of the battery(ies), apply baking soda to theseareas to neutralize the battery acid. Before reinstalling theexisting or new battery(ies), clean the baking soda fromthe battery tray or battery(ies) being sure to avoid contactwith skin and eyes. Determine source of contamination.NEVER install/reinstall a battery with a cracked or otherwisedamaged case.

66 1143190-M~04

Page 67: TDX SP/SR Base Owner's Manual

Setup and Maintenance

7.7 Using the Proper Batteries

1. Position battery on ground/flat surface as shown below.2. Visually inspect the battery to ensure proper polarity:

FOR WHEELCHAIRS USING 22NF BATTERIES

Batteries with terminal configuration (POSITIVE A on the leftand NEGATIVE Bon the right) as shown below MUST be used.Batteries that have the reverse terminal configuration MUST notbe used - otherwise injury and damage may occur.

Terminals must be have a cross hole C in them as shown below.

PROPER BATTERIESTO USE

DO NOT USE THIS TYPEOF BATTERY

FOR WHEELCHAIRS USING GP24 BATTERIES

Batteries with terminal configuration (POSITIVE A on the rightand NEGATIVE Bon the left) as shown below MUST be used.Batteries that have the reverse terminal configuration MUST notbe used - otherwise injury and damage may occur.

Terminals must be have a cross hole C in them as shown below.

PROPER BATTERIESTO USE

DO NOT USE THIS TYPEOF BATTERY

1143190-M~04 67

Page 68: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

7.8 Removing/Installing the Batteries From/Intothe Wheelchair

7.8.1 Removing the Batteries from the Wheelchair

CAUTION!Risk of DamageDamage to carpeting or flooring.– Place the wheelchair in a well ventilated area wherework can be performed without risking damage tocarpeting or floor covering.

22NF Batteries shown

1. Place the wheelchair in a well ventilated area.2. Verify the joystick On/Off switch is in the Off position and

disconnect joystick. Refer to 7.14.1 Disconnecting SPJ+ Joysticksor 7.15.2 Disconnecting the CMPJ+ Joysticks.

3. Remove the rear shroud, front shroud and battery retentionbracket. Refer to 7.5 Removing/Installing the WheelchairShrouds.

4. Disconnect the controller from the batteries at the rear of thewheelchair.

5. Slide battery tray A with batteries out.6. Disconnect the battery straps B.

Battery connection E located on top.

7. Disconnect batteries.8. Remove the front C battery.9. Slide the rear battery D forward and remove it from the tray.

7.8.2 Installing Batteries into the Wheelchair

WARNING!Risk of Serious InjuryImproperly installed battery tray can cause instabilityresulting in serious injury.– Ensure batteries and battery tray are installed properlyto maintain stability.

68 1143190-M~04

Page 69: TDX SP/SR Base Owner's Manual

Setup and Maintenance

Positioning of the batteries into the battery tray is completedwith battery tray positioned in wheelchair and partiallypulled out. Illustrations are shown without the wheelchairfor clarification purposes only.

1. Position the battery with battery connector bracket A againstthe back edge of the battery tray B in the orientation as shown.

Batteries MUST be installed in the orientation shown sothat the wiring harnesses can be connected together.

2. Position the remaining battery between the battery on the trayand battery stop C.

3. Connect batteries together D.4. Connect battery straps E.5. Slide the battery tray into the wheelchair6. Install the rear shroud, front shroud and battery retention

bracket. Refer to 7.5 Removing/Installing the WheelchairShrouds.

1143190-M~04 69

Page 70: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

7.9 Replacing Batteries and/or Battery CablesHave the following tools available: 7/16 inch (6pt) BoxWrench and Diagonal Cutters.

1. Remove the batteries from the wheelchair. Refer to 7.8Removing/Installing the Batteries From/Into the Wheelchair.

2. Cut the tie-wraps A that secure the battery terminal covers Bto the battery terminals.

3. Slide the RED battery terminal cover back on the red batterycable to expose the POSITIVE battery terminal C.

4. Slide the BLACK battery terminal cover back on the Blackbattery cable to expose NEGATIVE battery terminal D.

WARNING!– NEVER allow any of your tools and/or batterycable(s) to contact BOTH battery post(s) at thesame time. An electrical short may occur andserious personal injury or damage may occur.

5. Remove the locknut E that secures the bracket F of thePOSITIVE battery cable to the POSITIVE (+) battery post of thebattery.

70 1143190-M~04

Page 71: TDX SP/SR Base Owner's Manual

Setup and Maintenance

6. Remove the locknut G that secures the NEGATIVE batterycable H to the NEGATIVE (-) battery post of the battery.

7. Discard the existing battery.8. Position battery connector bracket I or wiring harness J onto

the new 22NF battery or GP24 battery as shown.9. Secure the NEGATIVE battery cable H to the NEGATIVE (-)

battery post with existing mounting screw K and locknut G.10. Secure the bracket F of the POSITIVE battery cable to the

POSITIVE (+) battery post with existing mounting screw L andlocknut E.

11. Position each battery terminal cover over top of each batteryterminal.

12. Secure battery terminal covers in place with one tie-wrap.13. Install batteries into wheelchair. Refer to 7.8 Removing/Installing

the Batteries From/Into the Wheelchair.

7.9.1 Cleaning Battery Terminals

WARNING!– Most batteries are not sold with instructions.However, warnings are frequently noted on the cellcaps. Read them carefully.

– DO NOT allow the liquid in the battery to come incontact with skin, clothes or other possessions. It isa form of acid and harmful or damaging burns mayresult. Should the liquid touch your skin, wash thearea IMMEDIATELY and thoroughly with cool water.In serious cases or if eye contact is made, seek medicalattention IMMEDIATELY.

1. Examine battery terminals for corrosion.2. Verify the plastic caps are in place over battery cell holes.

3. Clean terminals by using a battery cleaning tool, wire brush, ormedium grade sand paper.

Upon completion, areas should be shiny, not dull.

4. Carefully dust off all metal particles.

7.10 Adjusting Forks

This procedure must be performed by a qualified technician.

This procedure applies to both Forks.

1. Remove the retaining screw A securing the head tube coverB in place.

2. Remove the head tube cover (not shown) from the caster headtube C.

1143190-M~04 71

Page 72: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

3. To properly tighten caster journal system and guard againstflutter, perform the following check:

a. Tip the wheelchair forward, toward the floor.b. Pivot both forks D and casters Eto top of their arc

simultaneously.c. Let casters drop to bottom of arc (wheels should swing once

to one-side, then immediately rest in a straight downwardposition).

d. Adjust locknuts F according to freedom of caster swing.

4. Test wheelchair for maneuverability.5. Readjust locknuts if necessary, and repeat STEPS 1-3 until

correct.6. Snap headtube cover into the caster headtube.7. Reinstall retaining screws.

7.11 Removing/Installing the Footboard orAdjusting the Footboard Height

WARNING!– After ANY adjustments, repair or service and beforeuse, make sure that all attaching hardware is tightenedsecurely - otherwise injury or damage may result.

– Before performing any maintenance, adjustment orservice, verify that ON/OFF switch on the joystick isin the OFF position.

– do not stand on the flip-up footboard. When gettingin or out of the wheelchair, make sure that the flip-upfootboard is in the upward position.

WARNING!– LIMITED CLEARANCE BETWEENFOOTBOARD AND CASTER - The user’s feetmust remain on the footboard while operating thewheelchair. If the user’s feet are allowed to rest offthe side of the footboard they may come in contactwith the caster possibly resulting in injury.

Removing the Footboard

1. Remove the socket head screw A, three washersB, spacer Cand locknut D that secures the footboard E to the footboardsupport F.

2. Remove the footboard from the footboard support.

72 1143190-M~04

Page 73: TDX SP/SR Base Owner's Manual

Setup and Maintenance

Installing the Footboard

WARNING!– Pinch point may occur when rotating the footboardassembly.

1. Position the footboard onto the footboard support so that themounting holes in the wheelchair frame align with the desiredmounting holes in the footboard support.

2. Using the socket heat screw, three washers, spacer and locknutsecure the footboard to the footboard support.

Adjusting the Footboard Height

1. Remove the footboard. Refer to Removing the Footboard.2. Adjust the footboard to one of two mounting holes in the

footboard support to adjust the footboard height by 1 inch.3. Install the footboard. Refer to Installing the footboard

7.12 Adjusting the Footboard Angle

1. Loosen the jam nut and set screw located underneath on therear of the footplate.

2. Adjust the mounting screw in or out to obtain the desiredfootboard angle.

3. Thread the jam nut inward until it is flush with the footboardbracket.

4. Securely tighten the jam nut and washer to secure the mountingscrew in place.

1143190-M~04 73

Page 74: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

7.13 Repositioning Joystick

1. Turn the adjustment lock lever A to release the joystickmounting tube B from the joystick mounting bracket C.

2. Remove the joystick from the wheelchair.3. Remove the three hex screwsD and washersE that secures the

joystick mounting bracket to the threaded mounting bracket F.4. Reposition threaded mounting bracket on the inside of the

opposite arm tube G as shown.5. Using the three hex mounting screws and washers, secure

joystick mounting bracket to the threaded mounting bracket.6. Slide the joystick mounting tube through the joystick mounting

bracket to the desired position.7. Turn the adjustment lock lever to secure the joystick mounting

tube into the mounting bracket.

7.14 Disconnecting/Connecting the SPJ+Joysticks

The joystick connector is located at the rear of the seatframe.

7.14.1 Disconnecting the SPJ+ Joysticks

1. Hold the light grey collar portion A of the joystick connector Bwith one hand and the controller connectorC on the wheelchairin the other and disconnect them by pulling them apart.

7.14.2 Connecting the SPJ+ Joysticks

WARNING!– The joystick connector and controller connectorfit together in one way only. DO NOT force themtogether.

1. Hold the light grey collar portion A of the joystick connector Bwith one hand and the controller connectorC on the wheelchairin the other and align them.

2. Lightly push to engage the joystick connector and the controllerconnector.

74 1143190-M~04

Page 75: TDX SP/SR Base Owner's Manual

Setup and Maintenance

7.15 Disconnecting/Connecting the CMPJ+Joysticks

The joystick connector is located at the rear of the seatframe.

7.15.1 Connecting the CMPJ+ JoysticksEnsure the gaskets B are installed in the top connector capand between network connectors C.

1. Ensure the latch is pulled away from the network connector.2. Connect the network connector to the other connectors.3. Top D and Bottom E Connectors - Install connector caps onto

the network connector.4. Push the latch in to secure the network connectors and caps.5. If necessary secure excess cable using tie-wraps.

7.15.2 Disconnecting the CMPJ+ Joysticks

1. Pull the latch A away from the joystick connector.2. Disconnect the joystick connector from the remaining

connectors.

1143190-M~04 75

Page 76: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

8 Troubleshooting

8.1 Driving Performance

Solutions

Check forloose stemnuts/bolts,bearings orsigns of wear.

Check foruneven tirewear, bentfork/frameor loosehardware.

If pneumatic,check tiresfor correctand equalpressure.

WheelchairVeers Left orRight

X X X

SluggishTurn orPerformance

X X

CastersFlutter

X X X

Squeaks andRattles

X

Looseness inWheelchair

X X

Wheelchair 3Wheels

X X

8.2 ElectricalFor additional troubleshooting information and explanationof error codes, refer to the individual Electronics Manualsupplied with each wheelchair.

8.2.1 SPJ+, SPJ+ w/PSS or SPJ+ w/ACC JoysticksThe joystick information gauge and the service indicator giveindications of the type of fault or error detected by the controlmodule. When a fault is detected, the wheelchair may stop and notdrive. The LEDs on the information gauge may flash in a particularpattern or the service indicator light will flash. The number or typeof flashes indicates the nature of the error. If multiple errors arefound, only the first error encountered by the control module willbe displayed.

Information Gauge Display AAA Diagnostics

Display Description Definition Comments

All LEDs areoff.

Power is off.

76 1143190-M~04

Page 77: TDX SP/SR Base Owner's Manual

Troubleshooting

Display Description Definition Comments

All LEDs areon.

Power is on. Fewer than threeLEDs on impliesreduced batterycharge.

Left Red LEDis flashing.

Batterycharge islow.

The batteriesshould be chargedas soon aspossible.

Left to Right“chase”alternatingwith steadydisplay.

Joystick is inprogram-ming, in-hibit and/orchargingmode.

The steady LEDsindicate thecurrent stateof the batterycharge.

All LEDsare flashingslowly.

Joystick hasdetectedOut-of-Neutral-at-Power-Upmode.

Release thejoystick back toNeutral.

Service Indicator Light AAA Diagnostics

NUMBER OFFLASHES

ERROR CODEDESCRIPTION

POSSIBLE SOLUTION

1 User Fault Release joystick to neutraland try again.

2 Battery Fault Charge the batteries.

Check that battery cablesare connected properly.If necessary, replacebatteries.

3 Left Motor Fault Contact Invacare/Dealerfor service.

4 Right Motor Fault Contact Invacare/Dealerfor service.

1143190-M~04 77

Page 78: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

NUMBER OFFLASHES

ERROR CODEDESCRIPTION

POSSIBLE SOLUTION

5 Left Park BrakeFault

Ensure brake lever is inthe drive position beforeturning on the wheelchair.Ensure motor cable isplugged into the controller.

Contact Invacare/Dealerfor service.

6 Right Park BrakeFault

Ensure brake lever is inthe drive position beforeturning on the wheelchair.Ensure motor cable isplugged into the controller.

Contact Invacare/Dealerfor service.

7 Remote Fault Check to make surejoystick is connectedproperly. Turn Joystick offthen on.

Contact Invacare/Dealerfor service.

8 Controller Fault Contact Invacare/Dealerfor service.

NUMBER OFFLASHES

ERROR CODEDESCRIPTION

POSSIBLE SOLUTION

9 CommunicationsFault

Check joystick cableconnections. Checkjoystick cable andconnectors for damage.

Contact Invacare/Dealerfor service.

10 General Fault Contact Invacare/Dealerfor service.

11 Incompatible orincorrect Remote

Wrong type of remoteconnected. ContactInvacare/Dealer forservice.

8.2.2 CMPJ+ Joysticks or DisplaysError codes are displayed in the Fault Log on the hand helpprogrammer.

78 1143190-M~04

Page 79: TDX SP/SR Base Owner's Manual

Troubleshooting

SYMPTOM PROBABLECAUSE SOLUTIONS

LEFT BRAKEFAULT or RIGHTBRAKE FAULTdisplays andwheelchair doesnot drive.

Motor lock leversdisengaged (Errorcode E9 or E10).

Engage motor locklevers. Refer to Dis-engaging/EngagingMotor Lock Levers.

CHARGERPLUGGED INdisplays.

Battery chargerconnected (Errorcode E28).

Unplug batterycharger from thewheelchair. Refer toCharging Batteries.

BATTERY FAULTdisplays and thewheelchair does notdrive.

Batteries need to becharged (Error codeE14).

Charge batteries.Refer to ChargingBatteries.

If batteries fail tocharge properly,check batterycharger or replacebatteries. Refer toReplacing Batteriesand/or BatteryCables.

JOYSTICKTIMEOUT displaysand the wheelchairdoes not drive.

Joystick orinput device isdisconnected (Errorcode 32).

Turn off power,reconnect thejoystick of inputdevice and turnpower on.

SYMPTOM PROBABLECAUSE SOLUTIONS

JOYSTICK FAULTdisplays and thewheelchair does notdrive.

The joystick or inputdevice is sending avalue outside of thereverse, forward,left or right limits(Error codes E01,E02, E03 or E04).

Replace joystick orinput device.

NEUTRALTESTING displays.

The joystick neutraltest has failed (Errorcode E18).

Release the joystickand try to get thejoystick back intothe center-mostposition.

BAD JOYSTICKCAL VALUESdisplays and thewheelchair does notdrive.

The joystickcalibration valuesare outside of theexpected range(Error code E19).

Recalibrate thejoystick (joystickthrow procedure).

CTRL NOTCONNECTED

The CMPJ orDisplay module isnot communicatingwith the controlmodule (Error codeE200).

Check theconnectionsbetween the joystickor display and thecontroller. Turn thepower off and thenback on. Replacethe controller ifnecessary.

1143190-M~04 79

Page 80: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

SYMPTOM PROBABLECAUSE SOLUTIONS

CTRL COM FAULTdisplays and thewheelchair drivesslowly.

The controller hasdetermined a faultduring a previousturn-off process(Error code E41).

Turn the wheelchairoff and back on.

MISSINGCONFIGURATIONdisplays at powerup.

One or moredevices havebeen removed ordisconnected fromthe wheelchair.

Reconnect thedevice.

ATTENDANTACTIVE anddisplays.

The Proportionalor Digital Attendantcontrol is active andcan be used to drivethe chair.

This is normalbehavior.

Batteries drawexcessive currentwhen charging.

Battery failure.

Electricalmalfunction.

Have batterieschecked for shortedcell. Replace ifnecessary.

ContactDealer/Invacarefor service.

SYMPTOM PROBABLECAUSE SOLUTIONS

Battery indicatorflashes the chargelevel is low -immediately afterrecharge.

Battery failure.

Malfunctioningbattery charger.

Electricalmalfunction.

Check batteriesfor shorted cell.Replace if necessary.

ContactDealer/Invacarefor Service.

ContactDealer/Invacarefor Service.

Battery indicatorflashes the chargelevel is low - toosoon after beingrecharged.

Batteries notcharged.

Weak batteries.

Have chargerchecked.

Replace batteries ifnecessary. Refer toReplacing Batteriesand/or BatteryCables.

Motor “chatters” orruns irregular.

Motor/gearboxmalfunction.

Stop use ofWheelchair.ContactDealer/Invacarefor Service.

80 1143190-M~04

Page 81: TDX SP/SR Base Owner's Manual

Troubleshooting

SYMPTOM PROBABLECAUSE SOLUTIONS

Joystick erratic ordoes not respond asdesired.

Damaged motorcoupling.

Electricalmalfunction.

Controllerprogrammedimproperly.

ContactDealer/Invacarefor Service.

ContactDealer/Invacarefor Service.

ContactDealer/Invacareto have controllerreprogrammed.

Wheelchair doesnot respond tocommands.

Electricalmalfunction.

ContactDealer/Invacarefor Service.

Power indicatoroff - even afterrecharging.

Poor batteryterminal connection.

Have terminalscleaned.

8.3 Checking Battery Charge LevelThe following “Do’s” and “Don’ts” are provided for your convenienceand safety.

DON’T DO

Don’t perform any installationor maintenance without firstreading this manual.

Read and understand thismanual and any serviceinformation that accompaniesa battery and charger beforeoperating the wheelchair.

Don’t perform installation ormaintenance of batteries in anarea that could be damaged bybattery spills.

Move the wheelchair to a workarea before cleaning terminals,or opening battery box.

Don’t make it a habit todischarge batteries to thelowest level.

Recharge as frequently aspossible to maintain a highcharge level and extend batterylife.

Don’t use randomly chosenbatteries or chargers.

Follow recommendations in thismanual when selecting a batteryor charger.

Don’t put new batteries intoservice before charging.

Fully charge a new batterybefore using.

Don’t tip or tilt batteries. Use a carrying strap to remove,move or install a battery.

Don’t tap on clamps andterminals with tools.

Push battery clamps on theterminals. Spread clamps widerif necessary.

Don’t mismatch your batteryand chargers.

Use only a gel charger for a gelbattery.

1143190-M~04 81

Page 82: TDX SP/SR Base Owner's Manual

Invacare® TDX® SP and TDX SR Power Wheelchair Base

8.4 Usability SurveyPlease complete the survey below to evaluate this manual.

Your participation in the evaluation assists in the development

of effective and usable manuals for our customers.

The survey is also available online:

http://www.invacare.com/TechnicalDocumentSurvey

1. Please indicate your primary involvement with the product (choose one):

q Product User/Ownerq User Assistantq Product Dealer

q Product Service Technicianq Health Care Providerq Other (please specify):

____________________________

2. Please indicate which product manual you are evaluating:____________________________________________________________

3. Evaluate the content:

YES NO

After reading this document, do you have a betterunderstanding of how to use the product?

q qDo you have a better understanding of any limitationson the use of this product?

q qIs there any irrelevant information? q qIs the Table of Contents useful? q qDoes any information seem inaccurate/misleading? q qDo you understand that misuse of the product can causeinjury or damage?

q q

Explain:________________________________________________________________________________________________________________________

4. Evaluate the Warnings/Cautions:

YES NO

Are there any warnings/cautions that you do notunderstand?

q qAre there too many warnings/cautions? q qAre there warnings/cautions that you feel do not applyto this product?

q q

Explain:________________________________________________________________________________________________________________________

5. Evaluate the style:

YES NO

Is anything hard to locate/follow? q qAre any headings missing/confusing? q qAre there too many headings? q qShould any material be a bulleted list or checklist insteadof numbered steps or a paragraph?

q qIs there material that might be clarified by a visual? q q

Explain:________________________________________________________________________________________________________________________

82 1143190-M~04

Page 83: TDX SP/SR Base Owner's Manual

Troubleshooting

6. Evaluate the illustrations:

YES NO

Are the illustrations useful? q qDo the illustrations need more or less detail? q qIs the number/size of illustrations adequate? q q

Explain:________________________________________________________________________________________________________________________

7. Do you have suggestions for other ways of making this document easier to use?

Explain: YES NO

________________________________________________________________________________________ q q

Thank You! Thank you for completing this survey. If you have any questions or we may be ofassistance to you, please feel free to contact us.

Send your survey to Invacare Technical Writing Department: [email protected] Invacare Corporation: One Invacare Way, Elyria, Ohio 44035 FAX: 440–329–6975

1143190-M~04 83

Page 84: TDX SP/SR Base Owner's Manual

USA One Invacare Way, Elyria, Ohio USA, 44036–2125, 800–333–6900

Canada 570 Matheson Blvd E Unit 8, Mississauga Ontario, L4Z 4G4 Canada, 800–668–5324

www.invacare.com

1143190-M~04 2016-5-12

*1143190M~04*Making Life’s Experiences Possible™