T2.4 Performance Test Running in R78

description

T2.4 Performance. Test Running in R78. Timeline. T2.4 installed in R76 09-11-2010 First inspection on 16-11-2010 after 200k pulses Little or no wear/dust seen Target restarted and run for another 400k 2 nd inspection 23-11-2010 Total pulses at inspection 615k. - PowerPoint PPT Presentation

Transcript of T2.4 Performance

Page 1: T2.4 Performance

T2.4 Performance

Test Running in R78

Page 2: T2.4 Performance

Timeline

• T2.4 installed in R76 09-11-2010• First inspection on 16-11-2010 after 200k

pulses• Little or no wear/dust seen• Target restarted and run for another 400k• 2nd inspection 23-11-2010• Total pulses at inspection 615k

Page 3: T2.4 Performance

1st inspection – Top Bearing

Page 4: T2.4 Performance

1st inspection – Top Shaft

Page 5: T2.4 Performance

1st inspection bottom of shaft

No material visible in this region

Dust Catcher

Page 6: T2.4 Performance

T2.4 2nd Inspection – Top Bearing

Page 7: T2.4 Performance

Top Bearing close up

Small amount of Material on side of flat

Page 8: T2.4 Performance

Top Shaft wear surface

Smudge of material on weararea of shaft

Page 9: T2.4 Performance

Bottom Shaft

Dust Catcher

No material visible in this region

Page 10: T2.4 Performance

Odd deposit on top of Stator?

Page 11: T2.4 Performance

Run 2 Minimum PositionSome changes seenMin BCD has driftedupwards over time.

Pulse to pulse Variability approx. 0.8mmstill well within what is acceptable for MICE

Thanks to Ed for new DAQ plots

Page 12: T2.4 Performance

Run 2 AccelerationAcceleration is flat.Variability acceptable.

Note that we think weunderstand difference between old and new DAQacceleration values.

Page 13: T2.4 Performance

Comments

• No significant wear/dust after 600k pulses• No new wear seen on 2nd inspection• Was wear seen on 16th “bedding in” ?• Next inspection on 31-11-2010• Should be over 1 million pulses on clock