t and Berg Encoder Ref Guide

download t and Berg Encoder Ref Guide

of 186

Transcript of t and Berg Encoder Ref Guide

  • 8/11/2019 t and Berg Encoder Ref Guide

    1/186

    ST.RE.VOY.E57xx.1Issue 1

    ENGLISH (UK)

    REFERENCE GUIDE

    E5714/E5740-xxx DSNG,E5750 DENG,

    E5784 4:2:0 HD DSNG andE5788 4:2:2 Encoders

    Build Version 3.13 and later

    E5740 Encoder

    E5784 Encoder

  • 8/11/2019 t and Berg Encoder Ref Guide

    2/186

    Preliminary Pages

    Page ii Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    Issue 1first published in 2008 by:TANDBERG TELEVISION LTD

    REGISTERED ADDRESS :UNIT 2 S TRATEGIC P ARK, C OMINES WAY,HEDGE END, S OUTHAMPTON ,HAMPSHIRE ,SO30 4DAUNITED KINGDOM

    Registered Company Number 03695535

    This document and the information contained in it is theproperty of TANDBERG Television Ltd and may be thesubject of patents pending and granted. It must not beused for commercial purposes nor copied, disclosed,reproduced, stored in a retrieval system or transmittedin any form or by any means (electronic, mechanical,photocopying, recording or otherwise), whether in

    whole or in part, without TANDBERG Televisions priorwritten agreement.

    2008 TANDBERG Television Ltd. All rights reserved.

    SVENSKA LS DETTA FRST!

    Om Ni inte frstr informationen i denna handbok ARBETA D INTE MED DENNA UTRUSTNING.

    En versttning till detta sprk av denna handbok kan ocks anskaffas,p Er bekostnad.

    ENGLISH (UK)READ THIS FIRST!

    If you do not understand the contents of this manualDO NOT OPERATE THIS EQUIPMENT.

    Also, translation into any EC official language of this manual can bemade available, at your cost.

    !

    / .

    , .

    DEUTSCH

    LESEN SIE ZUERST DIESEN HINWEIS!Sollte Ihnen der Inhalf dieses Handbuches nicht klar verstndlich sein,

    dannBEDIENEN SIE DIESE GERTE NICHT!

    Eine bersetzung des Handbuches in diese Sprache ist gegenBerechnung lieferbar.

    ESPAOL LEA ESTE AVISO PRIMERO!

    Si no entiende el contenido de este manualNO OPERE ESTE EQUIPO.

    Podemos asimismo suministrarle una traduccin de este manual al(idioma) previo pago de una cantidad adicional que deber abonar

    usted mismo.

    FRANAIS AVANT TOUT, LISEZ CE QUI SUIT!

    Si vous ne comprenez pas les instructions contenues dans ce manuelNE FAITES PAS FONCTIONNER CET APPAREIL.

    En outre, nous pouvons vous proposer, vos frais, une versionfranaise de ce manuel.

    ITALIANOLEGGERE QUESTO AVVISO PER PRIMO!

    Se non si capisce il contenuto del presente manualeNON UTILIZZARE LAPPARECCHIATURA.

    anche disponibile la versione italiana di questo manuale, ma il costo a carico dellutente.

    PORTUGUS LEIA O TEXTO ABAIXO ANTES DE MAIS NADA!

    Se no compreende o texto deste manualNO UTILIZE O EQUIPAMENTO.

    O utilizador poder tambm obter uma traduo do manual para oportugus prpria custa.

    NEDERLANDSLEES DIT EERST!

    Als u de inhoud van deze handleiding niet begrijptSTEL DEZE APPARATUUR DAN NIET IN WERKING.

    U kunt tevens, op eigen kosten, een vertaling van deze handleidingkrijgen.

    DANSK LS DETTE FRST!Udstyret m ikke betjenes

    MEDMINDRE DE TIL FULDE FORSTR INDHOLDET AF DENNEHNDBOG.

    Vi kan ogs for Deres regning levere en dansk oversttelse af dennehndbog.

    SUOMI LUE ENNEN KYTT!

    Jos et ymmrr ksikirjan sislt L KYT LAITETTA.

    Ksikirja voidaan mys suomentaa asiakkaan kustannuksella.

  • 8/11/2019 t and Berg Encoder Ref Guide

    3/186

    Preliminary Pages

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page iii ST.RE.VOY.E57xx.1

    List of Contents

    Chapter 1: Introduction to the Basic EncoderGives a general description of the equipment and its main features and functions. Identifiesthe controls, indicators and connectors on the front and rear panels.

    Chapter 2: Installing the EquipmentProvides a guide to the suitability of an installation and gives detailed procedures for thepreparation and installation of the equipment. Also details the external connectors andprovides important safety information .

    Chapter 3: Options and UpgradesThis chapter describes the options and upgrades available for theE57xx series of Encoder models.

    Chapter 4: Operating the Equipment LocallyDescribes local control in detail. Provides the power up/power down procedures and other

    general operating/control/set-up procedures.Chapter 5: Web Browser Interface

    Details how to access and use the Web Browser Interface for a range of diagnostic and otherutilities.

    Chapter 6: Preventive Maintenance and Fault-findingDetails routine maintenance tasks to be performed by the operator and provides generalservicing advice and fault-finding information. Provides information regarding warranty andmaintenance available from Customer Services. Gives relevant disposal information.

    Annex A: GlossaryAnnex B: Technical SpecificationAnnex C: Alarms/Status Lists

    NOTEFurther information is available in the Annexes of the References Guides referred to inChapter 1, Table 1.1.

  • 8/11/2019 t and Berg Encoder Ref Guide

    4/186

    Preliminary Pages

    Page iv Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    About this Reference GuideThis Reference Guide provides information about the Voyager specific functionality of theE5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders.

    This Reference Guide should be kept in a safe place for reference for the life of theequipment. It is not intended that this Reference Guide will be amended by the issue of

    individual pages. Any revision will be by a complete reissue. Further copies of this ReferenceGuide can be ordered from the address shown on page vi . If passing the equipment to a thirdparty, also pass the relevant documentation.

    Issues of this Reference Guide are listed below:

    Issue Date Release Comments

    1 Mar 2008 3.13.0 Initial release.

    This guide is intended as a companion volume to the following guides: ST.RE.E10074, E5710, E5720, E5770 and E5775 SD Encoders. ST.RE.E10135, E5780 and E5782 Encoders.

    NomenclatureThe terms RS-232 and RS-422 have been superseded by EIA-232 and EIA-422. However,because the original names are inscribed on the Encoder the original terms are used in thetext of this Reference Guide.

  • 8/11/2019 t and Berg Encoder Ref Guide

    5/186

    Preliminary Pages

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page v ST.RE.VOY.E57xx.1

    Acknowledgements

    GeneralAll best endeavours have been made to acknowledge registered trademarks and trademarksused throughout this Reference Guide. Any notified omissions will be rectified in the next issue

    of this Reference Guide. Some trademarks may be registered in some countries but not inothers.

    Registered trademarks and trademarks used are acknowledged below and marked with theirrespective symbols. However, they are not marked within the text of this Reference Guide.

    Registered TrademarksAC-3 , Dolby Digital and Pro Logic are registered trademarks of Dolby LaboratoriesLicensing Corporation.

    DTS is a registered trademark of Digital Theater Systems, Inc.

    Ethernet is a registered trademark of Xerox Corporation.

    Motorola is a registered trademark of Motorola Inc.

    Musicam is a registered trademark of Thomson and Tldiffusion de France (TDF), Europe,and is a registered trademark of CCS (now Musicam USA Incorporated), USA.

    Wegener is a registered trademark of Wegener Communications Inc.

    XILINX is a registered trademark of Xilinx Inc.

    TrademarksEthafoam is a trademark of The Dow Chemical Company.

    Pozidriv is a trademark of European Industrial Services.Reflex is a trademark of TANDBERG Television.

    Stratocell is a trademark of the Sealed Air Corporation.

    STREAMS is a trademark of TANDBERG Television.

    Windows NT is a trademark of Microsoft Corporation.

  • 8/11/2019 t and Berg Encoder Ref Guide

    6/186

    Preliminary Pages

    Page vi Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    Warnings, Cautions and Notes

    Heed WarningsAll warnings on the product and in the operating instructions should be adhered to. Themanufacturer can not be held responsible for injuries or damage where warnings and cautions

    have been ignored or taken lightly.

    Read InstructionsAll the safety and operating instructions should be read before this product is operated.

    Follow InstructionsAll operating and use instructions should be followed.

    Retain InstructionsThe safety and operating instructions should be retained for future reference.

    WARNINGS.WARNINGS GIVE INFORMATION WHICH, IF STRICTLY OBSERVED, WILL PREVENT PERSONAL

    INJURY OR DEATH, OR DAMAGE TO PERSONAL PROPERTY OR THE ENVIRONMENT. THEY ARE BOXED AND SHADED FOR EMPHASIS, AS IN THIS EXAMPLE, AND ARE PLACED

    IMMEDIATELY PRECEDING THE POINT AT WHICH THE READER REQUIRES THEM.

    CAUTIONSCautions give information which, if strictly followed, will prevent damage to equipment or other goods.They are boxed for emphasis, as in this example, and are placed immediately preceding the point at

    which the reader requires them.

    NOTESNotes provide supplementary information. They are highlighted for emphasis, as in this example, andare placed immediately after the relevant text.

    EMC ComplianceThis equipment is certified to the EMC requirements detailed in Annex B, TechnicalSpecification . To maintain this certification, only use the leads supplied or if in doubt contactCustomer Services.

  • 8/11/2019 t and Berg Encoder Ref Guide

    7/186

    Preliminary Pages

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page vii ST.RE.VOY.E57xx.1

    Contact Information

    TANDBERG Television Customer Services

    Support Services

    Our primary objective is to provide first class customer care that is tailored to your specificbusiness and operational requirements. All levels are supported by one or more serviceperformance reviews to ensure the perfect partnership between TANDBERG Television andyour business.

    Warranty

    All TANDBERG Products and Systems are designed and built to the highest standards andare covered under a comprehensive 12 month warranty. (Voyager Products have a 24 Monthswarranty)

    Levels of Continuing TANDBERG Television Service Support

    For standalone equipment, TANDBERG Television BASIC Advantage is the value for moneychoice for you. BASIC provides you with year-by-year Service long after the warranty hasexpired.

    For systems support you can choose either Gold or Silver Advantage . These packages aredesigned to save you costs and protect your income through enlisting the help of TANDBERGTelevision support specialists.

    VOYAGER Advantage is the truly mobile service solution. This provides a packagespecifically designed to keep you mobile and operational.

    Call TANDBERG Sales for more details.

    Where to Find UsEurope, Middle East +44 (0) 23 8048 4455and Africa: Fax: +44 (0) 23 8048 4467

    [email protected]

    Americas: +888 671 1268 (US and Canada)+678 812 6255 (Outside of mainland US)[email protected]

    China: +86 10 6856 0260 (Beijing)

    +852 2530 3215 (Hong Kong)

    [email protected]/NZ: +61 2 8923 0450

    [email protected]

    Internet Address: http://www.tandbergtv.com

  • 8/11/2019 t and Berg Encoder Ref Guide

    8/186

    Preliminary Pages

    Page viii Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    Technical Training

    Training Courses

    TANDBERG Television provides a wide range of training courses on the operation andmaintenance of our products and on their supporting technologies. TANDBERG can provideboth regularly scheduled courses and training tailored to individual needs. Courses can be runeither at your premises or at one of our dedicated training facilities.

    Where to Find Us

    For further information on TANDBERG Television's training programme please contact us:

    International Telephone: +44 23 8048 4229International Facsimile +44 23 8048 4467

    E-mail Address: [email protected] Address http://www.tandbergtv.com

    Customer Services and Technical Training Postal AddressTandberg TelevisionUnit 2Strategic ParkComines WayHedge EndSouthamptonHampshireSO30 4DAUnited Kingdom

    Return of EquipmentIf you need to return equipment for repair, please contact the Customer Services Helpdesk on+44 (0) 23 8048 4455. A Returns Authorisation Number (RAN) will be issued and full details ofthe unit will be logged. Please ensure the RAN number is clearly marked on the packaging ofthe unit. The unit should then be sent to the following address:

    Tandberg Television Customer ServicesUnit 1Strategic ParkComines WayHedge EndSouthamptonHampshireSO30 4DAUnited Kingdom

    Technical PublicationsIf you need to contact TANDBERG Television Technical Publications regarding thispublication, e-mail: [email protected].

  • 8/11/2019 t and Berg Encoder Ref Guide

    9/186

  • 8/11/2019 t and Berg Encoder Ref Guide

    10/186

    Introduction to the Basic Encoder

    Page 1-2 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    BLANK

  • 8/11/2019 t and Berg Encoder Ref Guide

    11/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-3 ST.RE.VOY.E57xx.1

    1.1 Scope of this Reference Guide

    1.1.1 How to Use This Reference GuideThis Reference Guide is intended to act as a companion volume to the other guides shown inTable 1.1 .

    Table 1.1: Associated Guides

    Encoders in This Reference Guide Associated evo5000 Encoders Associated Reference Guide

    E5714/E5740-xxx DSNG, E5750 DENG E5710, E5720, E5770 and E5775 ST.RE.E10074

    E5784 and E5788 HD DSNG Encoders E5780 and E5782 ST.RE.E10135

    1.1.2 Who Should Use This Reference GuideThis Reference Guide has been written to describe the Voyager functionality of theTANDBERG Television E57xx range of Standard Definition (SD) and High Definition (HD)

    Encoders. These Encoders are referred to throughout this Reference Guide as Encoder(s)unless there is a specific difference, where they will be referred to by the model number.

    WARNINGDO NOT REMOVE THE COVERS OF THIS EQUIPMENT. HAZARDOUS VOLTAGES ARE PRESENT

    WITHIN THIS EQUIPMENT AND MAY BE EXPOSED IF THE COVERS ARE REMOVED. ONLYTANDBERG TELEVISION TRAINED AND APPROVED SERVICE ENGINEERS ARE PERMITTED TO

    SERVICE THIS EQUIPMENT.

    CAUTIONUnauthorised maintenance or the use of non-approved replacements may affect the equipment

    specification and invalidate any warranties.

    This Reference Guide does not include any maintenance information or procedures whichwould require the removal of covers.

    1.1.3 Build VersionThis Reference Guide has been written to cover the functionality in Table 1.2

    Table 1.2: Build Version

    All Encoders

    Build Version 3.13.0 and later

    The Build version indicates the status of the Encoder and refers to an overall number whichencompasses all the various software/firmware versions of video, audio, etc. in the BaseBoard.

    The current Build version can be found in the Bui l d Menu (see Chapter 4, Operating theEquipment Locally, Figure 4.9 ). This number should be quoted in all correspondence withTANDBERG Television.

  • 8/11/2019 t and Berg Encoder Ref Guide

    12/186

    Introduction to the Basic Encoder

    Page 1-4 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    1.1.4 What Equipment is Covered by This Reference Guide

    Standard Definition Encoder Models

    Each model of Encoder comprises an enclosure with a Base Board and Modulator fitted asstandard. The E5714 and E5740 are fitted with a Satellite Modulator; the E5750 is fitted withan OFDM Modulator.

    There may be vacant slots for option modules; depending on type and options already fitted.These slots can be occupied by any combinations of modules shown in Chapter 3, Optionsand Upgrades .

    Figure 1.1: E5714 Encoder Front View

    Figure 1.2: E5740 Encoder Front View

    Table 1.3: SD Encoder Model Descriptions

    ModelNumber

    MarketingCode

    Description

    E5714 Encoder M2/VOY/E5714 1U MPEG-2 DSNG Encoder with Satellite modulator. Has 4:2:0/4:2:2 1 video encoding mode and fully exhaustive motion estimation. L-bandversions are DVB-S2 capable.

    E5740 Encoder M2/VOY/E5740-IF 2U MPEG -2 DSNG Encoder with IF output satellite modulator. Has4:2:0/4:2:2 1 video encoding mode and fully exhaustive motionestimation . DVB-S2 capable.

    E5740 Encoder M2/VOY/E5740-LBAND 2U MPEG-2 DSNG Encoder with L-band output Satellite Modulator. Has4:2:0/4:2:2 1 video encoding mode and fully exhaustive motion estimation.DVB-S2 capable.

    E5750 Encoder M2/VOY/E5750 2U MPEG-2 DENG Encoder with OFDM modulator. Has 4:2:0/4:2:2 1video encoding mode and fully exhaustive motion estimation.

    E5750 Encoder M2/VOY/E5750/48V As M2/VOY/E5750 but fed from 48 Vdc supply.

    1 4:2:2 is only available when software option M2/ESO2/422 is purchased.

  • 8/11/2019 t and Berg Encoder Ref Guide

    13/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-5 ST.RE.VOY.E57xx.1

    High Definition Encoder Models

    Each model of Encoder comprises an enclosure with a Base Board and Modulator fitted asstandard. The E5784-IF and E5788-IF are fitted with a IF Satellite Modulator; theE5784-LBAND and E5788-LBAND is fitted with an L-Band Modulator. All of these Modulatorsare DVB-S2 capable.

    Figure 1.3: E5784 HD Encoder Front View

    There are four vacant slots for option modules. These slots can be occupied by anycombinations of modules shown in Chapter 3, Options and Upgrades .

    Table 1.4: HD Encoder Model Descriptions

    ModelNumber

    MarketingCode

    Description

    E5784 Encoder M2/VOY/E5784-IF MPEG-2 HD DSNG Encoder with 4:2:0 video encoding and IF outputDVB-S2 capable satellite modulator.

    E5784 Encoder M2/VOY/E5784-LBAND MPEG-2 HD DSNG Encoder with 4:2:0 video encoding and L-BandDVB-S2 capable satellite modulator.

    E5788 Encoder M2/VOY/E5788-IF MPEG-2 HD DSNG Encoder with 4:2:0/4:2:2 video encoding and IFDVB-S2 capable satellite modulator.

    E5788 Encoder M2/VOY/E5788-LBAND MPEG-2 HD DSNG Encoder with 4:2:0/4:2:2 video encoding andDVB-S2 capable L-Band output satellite modulator.

    1.2 Role of the Encoder in a System

    1.2.1 Typical SystemThe Encoder is a transportable digital exciter designed specifically for mobile contributionapplications. It is compact and lightweight, fully MPEG-2 and DVB/DVB-S2 or ATSC compliantand has high performance for the transmission of studio-quality video material. The equipmentis designed to be suitable for both flyaway use (within an appropriate flight case) and truck

    installation.The E5714 and E5740 contain the same high performance Encoder.The E5714-IF is a 1U chassis housing the Encoder and a QPSK Satellite Modulator. TheE5714-LBAND is a 1U chassis housing the Encoder and an L-Band Satellite Modulator. TheE5740 is a 2U chassis housing the Encoder and a Satellite Modulator capable of QPSK,8PSK 2, 16QAM 3 and DVB-S2 (QPSK, 8PSK, 16APSK) modulation.

    The Encoder has one card, containing a single video encoder, two stereo audio encoders(dual standard MPEG-1 (layer 2)/Dolby Digital (AC-3) 4), composite video decoder, CA 5, data

    2 8PSK is only available when software option M2/ESO2/SM38PSK is purchased.3

    16QAM is only available when software option M2/ESO2/SM316QAM is purchased.4 Dolby Digital (AC-3) is only available when software option M2/ESO2/AC3 is purchased.5 CA relates to RAS and BISS. RAS and BISS are only available when software options M2/ESO2/RAS and M2/EDCOM2/BISS arepurchased. A E57xx Encoder may be fitted with both RAS and BISS options but only one scrambling format can be used at any onetime. BISS is available from Build version 2.1.0 but BISS- is not supported before Build version 2.2.0.

  • 8/11/2019 t and Berg Encoder Ref Guide

    14/186

    Introduction to the Basic Encoder

    Page 1-6 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    input and general purpose VBI extraction and encoding circuitry. It also contains either asatellite modulator or an OFDM modulator.

    High quality 4:2:0 or 4:2:2 6 video encoding is ensured by the inclusion of digital noisereduction techniques 7 and many other proprietary algorithms as well as standard MPEGcompression techniques. Fully Exhaustive motion estimation is also used.

    Video can be input to the unit in serial digital component (SDI) format or composite analogue(PAL/NTSC). There is also a logo overlay facility allowing broadcasters to trademark material.

    The audio functionality supports multiple sampling frequencies, bit-rates and coding modes. Audio can be input in balanced analogue, digital AES/EBU input as a discrete channel orembedded on serial digital video. Various coding standards are supported, including LinearPCM. Additional audio channels can be accommodated by purchasing the option moduleM2/EOM2/AUDLIN2.

    Unit functionality can be further extended with option modules (see Chapter 3, Options andUpgrades ).

    1.2.2 DSNG SD Systems (E5714-IF/E5714-LBAND/E5740 Encoders)

    Overview

    Figure 1.4: Typical DSNG Encoder Configuration

    E5714-IF/E5714-LBAND Encoder

    The satellite modulator within the E5714-IF Encoder supports QPSK modulation inaccordance with EN 300 421 (DVB-S). It provides a main and monitoring IF Output. The IFfrequency can be tuned between 50 MHz and 90 MHz.

    The E5714-LBAND Encoder also supports high-order modulation and DVB-S2 (EN 302 307).

    E5740 Encoder

    The satellite modulator fitted within the E5740 is capable of QPSK modulation in accordancewith EN 300 421 (DVB-S) / EN 302 307 (DVB-S2), and is also capable of 8PSK and 16QAMmodulation in accordance with EN 301 210 (DVB-DSNG). It is available in two variants. Oneprovides an IF output tuneable in the range 50 MHz to 180 MHz. The other provides anL-band output tuneable in the range 950 MHz to 1750 MHz.

    6 4:2:2 is only available when software option M2/ESO2/422 is purchased.7 Noise reduction is only available when software option M2/ESO2/NR is purchased.

    Tx Rx

    Up-link equipment(including Up-converter

    and High Power Amplifier)

    Down-link equipment(including Low NoiseBlock andDown-converter)

    IFVIDEOAUDIOASYNC DATA

    SYNC DATA

    Encoder Modulator

    VIDEO (ANALOGUE)VIDEO (DIGITAL)

    AUDIO

    SYNC DATAASYNC DATA

    DSNG Encoder

    ALARMREMOTECNTRLAUTHORIZEDLOCK

    STATUSBERSTATUS MULTIFUNCTIONALDISPLAY

    ALTEIA

    SatelliteReceiver

  • 8/11/2019 t and Berg Encoder Ref Guide

    15/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-7 ST.RE.VOY.E57xx.1

    1.2.3 DENG SD Systems (E5750 Encoder)

    E5750 Encoder Radio Tx Radio Rx

    Rec / Mon Equipment

    70 MHz IF

    Figure 1.5: Typical SD DENG System Configuration

    The OFDM modulator fitted in the E5750 takes the Encoders output transport stream, anduses Coded Orthogonal Frequency Division Multiplexing (COFDM) to spread the data over1705 carriers (2k mode) or 6817 carriers (8k mode). This means that relatively low data ratescan be used on each carrier frequency, and any multipath effects (ghosting) which occuraffects only a small amount of data.

    The carriers are closely spaced so that their sidebands overlap, but due to the orthogonalrelationship between carrier frequencies they do not interfere with each other. This makes thesystem spectrally efficient.

    Noise, multipath effects, co-channel interference and other impairments can cause some bitsto be received in error. Therefore, Forward Error Correction (FEC) consisting of Reed-Solomon (RS) coding followed by convolution coding is used to add extra bits to thetransmitted signal. This allows a large number of errors at the receive end to be corrected byconvolutional (Viterbi) decoding followed by RS decoding.

    Five convolutional rates are available: 1/2,2/3,

    3/4,5/6 and

    7/8. These provide differentcompromises between bit-rate and ruggedness.

    The modulation scheme used on each carrier can either be QPSK, 16QAM, or 64QAM. Thesealso provide different compromises between bit-rate and ruggedness, QPSK being the mostrugged.

    Four guard intervals are available 1/32 , 1/16 , 1/8, and 1/4. These are used to reduce the effects ofintersymbol interference at the receive end caused by multipath propagation.

    The output of the modulator is 70 MHz IF for connection to a suitable radio transmitter, suchas the TANDBERG CT2636 Out-door Unit. When equipped with the Triax 8 Adaptor board(TANDBERG part nos: 12-1284-030 and 13.1174.000) the E5750 Encoder provides a Triaxoutput with 70 MHz, +48 Vdc and control signalling on a single Triax cable.

    1.2.4 DSNG HD Systems (E5784/E5788 Encoders)

    Overview

    The Encoder is a transportable digital exciter designed specifically for mobile contributionapplications. It is compact and lightweight, fully MPEG-2 and DVB/DVB-S2 or ATSC compliantand has high performance for the transmission of studio-quality video material. The equipmentis designed to be suitable for both flyaway use (within an appropriate flight case) and truckinstallation.

    The Encoder has two video encoders (HD and SD), two stereo audio encoders (dual standardMPEG-1 (layer 2)/Dolby Digital (AC-3) 9), composite video decoder, CA 10 , data input andgeneral purpose VBI extraction and encoding circuitry. It also contains a satellite modulator.

    8

    TANDBERG purchasable hardware option M2/EOM2/TRIAX.9 Dolby Digital (AC-3) is only available when software option M2/ESO2/AC3 is purchased.10 CA relates to RAS and BISS. RAS and BISS are only available when software options M2/ESO2/RAS and M2/EDCOM2/BISS arepurchased. A E57xx Encoder may be fitted with both RAS and BISS options but only one scrambling format can be used at any onetime.

  • 8/11/2019 t and Berg Encoder Ref Guide

    16/186

    Introduction to the Basic Encoder

    Page 1-8 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    High quality 4:2:0 or, as an option for the E5788 HD Encoder, 4:2:2 11 video encoding isensured by the inclusion of digital noise reduction techniques 12 and many other proprietaryalgorithms as well as standard MPEG compression techniques.

    Video can be input to the unit in serial digital component (SDI) format or composite analogue(PAL/NTSC). There is also a logo overlay facility allowing broadcasters to trademark material.

    The audio functionality supports multiple sampling frequencies, bit-rates and coding modes. Audio can be input in balanced analogue, digital AES/EBU input as a discrete channel orembedded on serial digital video. Various coding standards are supported, including LinearPCM. Additional audio channels can be accommodated by purchasing an option module .

    Unit functionality can be further extended with option modules (see Chapter 3, Options andUpgrades ).

    DSNG Systems

    Figure 1.6: Typical HD DSNG Encoder Configuration

    11 4:2:2 is only available when software option M2/ESO2/422 and M2/ESO2/HD422 is purchased.12 Noise reduction is only available when software option M2/ESO2/NR and M2/ESO2/HDNR is purchased.

    Tx Rx

    Up-link equipment(including

    Up-converter andHigh Power Amplifier)

    Down-link equipment(including Low NoiseBlock and

    Down-converter)

    IF VIDEO AUDIOASYNC DATASYNC DATA

    Encoder Modulator

    VIDEO (ANALOGUE)VIDEO (DIGITAL)

    AUDIOSYNC DATA

    ASYNC DATA

    DSNG Encoder

    ALARMREMOTECNTRLAUTHORIZEDLOCK

    STATUSBERSTATUS MULTIFUNCTIONALDISPLAY

    ALTEIA

    TT1280Satellite

  • 8/11/2019 t and Berg Encoder Ref Guide

    17/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-9 ST.RE.VOY.E57xx.1

    1.3 Summary of Features

    1.3.1 Audio/Video/DataPlease refer to the associated Reference Guide indicated in Table 1.1 .

    1.3.2 Standard OutputsThree ASI-C (copper) outputs supplying a DVB and ATSC 13 MPEG-2 transport stream aresupplied as standard.

    1.3.3 Standard-definition Encoders

    E5714-IF

    The internal satellite modulator within the E5714-IF supports QPSK modulation in accordancewith EN 300 421 (DVB-S). It provides a main and monitoring IF Output. The IF frequency canbe tuned between 50 MHz and 90 MHz in steps of 125 kHz. The maximum symbol rate is30 Msym/s from 60 MHz to 80 MHz (20 Msym/s at 50 MHz and 90 MHz).

    E5714-LBAND

    The internal satellite modulator within the E5714-LBAND supports BPSK (ETSI TR 101 198),QPSK (EN 300 421 [DVB-S]), 8PSK and 16QAM (EN 301 210 [DVB-DSNG], and 16APSKand 32APSK (EN 302 307 [DVB-S2]). The L-band frequency can be tuned 950 1750 MHz in1 kHz steps (0.2 30 Msym/s subject to limitations imposed by the Encoder.

    E5740 (IF and L-band)

    The satellite modulator fitted within the E5740 is capable of QPSK modulation in accordancewith EN 300 421 (DVB-S), 8PSK and 16QAM modulation in accordance with EN 301 210(DVB-DSNG) and 16APSK and 32APSK (EN 302 307 [DVB-S2]). It is available with eitherIF outputs, or L-band outputs.

    The IF output frequency can be tuned between 50 MHz and 180 MHz in 1 kHz steps. TheL-band output frequency can be tuned between 950 MHz and 1750 MHz in 1 kHz steps. Themaximum symbol rate is 66 Msym/s.

    E5750

    The OFDM modulator fitted within the E5750 provides an IF output at 70 MHz and 0 dBm. It iscapable of operating in 2k carriers, or 8k carriers transmission modes. It supports FEC ratesof 1/2,

    2/3,3/4,

    5/6 and7/8, and guard intervals of

    1/32 ,1/16 ,

    1/8, and1/4. It can provide QPSK,

    16QAM, or 64QAM modulation schemes. It is, also, possible to add a DVB-S/DVB-S2modulator to give a dual Terrestrial and Satellite capability.

    1.3.4 E5784/E5788 (IF and L-Band) High-definition EncodersThe satellite modulator fitted within the E5784/E5788 is capable of QPSK modulation inaccordance with EN 300 421 (DVB-S), also 8PSK and 16QAM modulation in accordance withEN 301 210 (DVB-DSNG), and 16APSK and 32APSK (EN 302 307 [DVB-S2]).

    The Encoder is available with either IF outputs, or L-band outputs. The IF output frequencycan be tuned between 50 MHz and 180 MHz in 1 kHz steps. The L-band output frequency canbe tuned between 950 MHz and 1750 MHz in 1 kHz steps. The maximum symbol rate is66 Msym/s.

    13 ATSC internal PSIP generation is not supported in Build versions 2.1.0 and 2.2.0.

  • 8/11/2019 t and Berg Encoder Ref Guide

    18/186

    Introduction to the Basic Encoder

    Page 1-10 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    1.3.5 Third-party Equipment

    Remote Control of High Power Amplifiers

    Control of an E2V Stellar N63xx and STA series High Power Amplifiers from the front panel ofthe Encoder. See Chapter 3, Options and Upgrades for more details.

    GigaSat Baseband MultiplexerThe E578x series of TANDBERG TV Encoders can integrate the GigaSat BasebandMultiplexer option module. See Chapter 3, Options and Upgrades for more details.

    NOTEThis option module is integrated by GIGASAT Ltd of Tring, Hertfordshire, UK ( http://www.gigasat.com) .

    1.4 Guided Tour1.4.1 General Information

    For information regarding standard rear panel connectors, please refer to the associatedReference Manual indicated in Table 1.1 .

    Always use the specified cables supplied for signal integrity and compliance with EMCrequirements (see Annex B, Technical Specification ).

    1.4.2 Standard-definition Encoder Rear Panel Description

    IntroductionThe Encoder provides connectors at the rear panel. All, except the power connector, arephysically located on the separate modules which comprise the Encoder.

    Figure 1.7: E5714 (1U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    RS-232/ RS-485Remote Control

    Base Board

    Option Slot2

    Audio Inand

    Audio Reference Out

    H Sync CompositeVideo

    ASI OutputsEthernetRS-232Data

    RS-422Data

    Alarm SDI In

    Technical EarthIF Out Main IF Out Monitor

    http://www.gigasat.com/http://www.gigasat.com/
  • 8/11/2019 t and Berg Encoder Ref Guide

    19/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-11 ST.RE.VOY.E57xx.1

    Figure 1.8: E5750 (2U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    The E5740-IF Encoder is similar to the E5750 and the E5740-LBAND is similar except theIF outputs are replaced by L-band outputs.

    Boards in the Basic SD EncoderThe basic Encoder contains two boards mounted horizontally in the enclosure (see Figure1.8 ). Option modules can be fitted in the remaining slots (see Standard Definition EncoderModels on page 1-4 and Chapter 3, Options and Upgrades ).

    Table 1.5: Boards in the Basic SD Encoder

    Model Number Card

    E5714 S11171 Encoder Base Board

    S12376 Tuneable QPSK Modulator

    E5740-IF S11171 Encoder Base Board

    S13716 70/140 MHz Satellite Modulator

    E5714-LBAND S11171 Encoder Base Board

    S13499 L-Band Satellite Modulator

    E5740-LBAND S11171 Encoder Base Board

    S13719 L-Band Satellite Modulator

    E5750 S11171 Encoder Base BoardS12524 OFDM Modulator

    Access to the modules or boards in the basic Encoder is not required for normal operation andmay invalidate the warranty.

    TANDBERGTelevision use

    only

    Option Slots 4-6

    Technical Earth

    Option Slot 1

    Option Slot Option Slot 5 Option Slot 6

    Option Slot 1

    Audio Inand

    Audio Reference Out

    CompositeVideo

    ASIOutputs

    Alarm

    RS-232/RS-485Remote Control

    SDI InEthernet

    Base Board

    IF OutMain

    IF OutMonitor

    H Sync

    RS-232Data

    RS-422Data

  • 8/11/2019 t and Berg Encoder Ref Guide

    20/186

    Introduction to the Basic Encoder

    Page 1-12 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    1.4.3 High-definition Encoder Rear Panel Description

    IntroductionThe Encoder provides connectors at the rear panel (see Chapter 2, Installing the Equipment ).

    All, except the power connector, are physically located on the separate modules whichcomprise the Encoder.

    Only those connectors used are labelled in Figure 1.9 and Figure 1.10 .

    Figure 1.9: E5784/8 HD Encoder IF Rear Panel Component Parts and Connectors (mains supply)

    Figure 1.10: E5784/8 HD Encoder L-Band Rear Panel Component Parts and Connectors (mains supply)

    Boards in the Basic EncoderThe basic Encoder contains two boards mounted horizontally in the enclosure (see Figure1.8 ). Option modules can be fitted in the remaining slots (see Standard Definition EncoderModels on page 1-4 and Chapter 3, Options and Upgrades ).

    Option Slot 6

    CompositeVideo

    Audio In and AudioReference Out

    TechnicalEarth

    Option Slot 1

    H Sync ASI

    Outputs

    RS-232 Data

    RS-422 Data

    Alarm

    RemoteControl

    SDI InEthernet1 and 2

    HD SDI Input IF Out Main IF Out Monitor

    Option Slot 6

    CompositeVideo

    Audio In and AudioReference Out

    TechnicalEarth

    Option Slot 1

    H Sync ASI

    Outputs

    RS-232 Data

    RS-422Data

    Alarm

    RemoteControl

    SDI InEthernet1 and 2

    HD SDI Input L-Band OutMain

    L-Band OutMonitor

    L-BandIn

  • 8/11/2019 t and Berg Encoder Ref Guide

    21/186

    Introduction to the Basic Encoder

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 1-13 ST.RE.VOY.E57xx.1

    Table 1.6: Boards in the Basic HD Encoder

    Model Number Card

    E5784 S11171 Encoder Base Board

    (M2/VOY/E5784-IF) S13997 SATMOD-3 Satellite Modulator card with IF output

    S12681 HD Encoder Module

    E5784 S11171 Encoder Base Board

    (M2/VOY/E5784-LBAND) S14002 SATMOD-3 Satellite Modulator card with L-Band output

    S12681 HD Encoder Module

    E5788 S11171 Encoder Base Board

    (M2/VOY/E5788-IF) S13997 SATMOD-3 Satellite Modulator card with IF output

    S12681 HD Encoder Module

    E5788 S11171 Encoder Base Board

    (M2/VOY/E5788-LBAND) S14002 SATMOD-3 Satellite Modulator card with L-Band output

    S12681 HD Encoder Module

    Access to the modules or boards in the basic Encoder is not required for normal operation andmay invalidate the warranty.

  • 8/11/2019 t and Berg Encoder Ref Guide

    22/186

    Introduction to the Basic Encoder

    Page 1-14 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    BLANK

  • 8/11/2019 t and Berg Encoder Ref Guide

    23/186

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-1 ST.RE.VOY.E57xx.1

    Chapter 22. Installing the Equipment

    Contents2.1 Introduction ...................................................... . 2-3

    2.1.1 Read This First!...................................... 2-3 2.1.2 General .................................................. 2-3 2.1.3 Site Requirements .................................2-3

    Power Supplies ...................................... 2-3 Environment..................................... ...... 2-3 Lightning Protection ............................... 2-3

    2.1.4 EMC Compliance Statements ................ 2-3 EN 55022 / AS/NZS 3548 ...................... 2-3 FCC ....................................................... 2-3

    2.2 Preliminary Checks ........................................... 2-4 2.2.1 Mechanical Inspection ...........................2-4 2.2.2 Moving the Equipment Safely ................2-4

    2.3 Installing the Equipment.................................... 2-4 2.3.1 Fixing Method ........................................ 2-4 2.3.2 Cable Routing ........................................ 2-5 2.3.3 Equipment Access ................................. 2-5 2.3.4 Ventilation .............................................. 2-5

    2.4 A.C. Mains Operating Voltage and Earthing......2-7

    2.4.1

    A.C. Power Supply............................... .. 2-7

    2.4.2 Power Cable and Earthing ..................... 2-7 General .................................................. 2-7 Protective Earth/Technical Earth............ 2-7 Connecting the Encoder to the A.C.Power Supply................... ...................... 2-8

    2.5 -48 Vdc Power Supply................. ...................... 2-9 2.5.1 D.C. Power Supply................................. 2-9 2.5.2 Location of the D.C. Input Connector..... 2-9 2.5.3 Connecting the Equipment to the D.C.

    Power Supply...................... ................. 2-10 2.5.4 Technical Earth.................................... 2-10

    2.6 Signal Connections E5714/E5740/E5750 SDEncoders......................................................... 2-11 2.6.1 Introduction .......................................... 2-11

    Connection of Antennae.......................2-11 Cables..................................................2-11

    2.6.2 Rear Panel Connections ......................2-11 2.6.3 Connecting Up the Basic

    E5714/E5740/E5750 SD Encoder........2-12 2.6.4 Satellite Modulator IF Output (E5714-

    IF and E5740 IF).................................. 2-14 IF Out (Main)........................................2-14 IF Out (Monitor)....................................2-14

    2.6.5 Satellite Modulator L-Band Output(E5740-LBAND and E5714-LBAND)... 2-14 L-Band In ............................................. 2-14 L-Band Out (Main)................................2-15 L-Band Out (Monitor) ...........................2-15

    ASI Input .............................................. 2-15 2.6.6 OFDM Modulator Outputs (E5750) ......2-16

    IF Out 1................................................2-16 IF Out 2................................................2-16

    2.7 Signal Connections E5784/E5788 HDEncoders ......................................................... 2-17 2.7.1 General ................................................ 2-17 2.7.2 Introduction .......................................... 2-17 2.7.3 Satellite Modulator IF Output (E5784-

    IF/E5788-IF).........................................2-18 IF Out (Main)........................................2-18 IF Out (Monitor)....................................2-18

    2.7.4 Satellite Modulator L-Band Output(E5784-LBAND/E5788-LBAND)...........2-18 L-Band In ............................................. 2-18 L-Band Out (Main)................................2-19 L-Band Out (Monitor) ...........................2-19 Up-Converter Power.............................2-19

  • 8/11/2019 t and Berg Encoder Ref Guide

    24/186

    Installing the Equipment

    Page 2-2 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    List of FiguresFigure 2.1: Fitting the Encoder into a Rack (1U Encoder

    Shown) ..................................................................2-5 Figure 2.2: Air Path Through the Enclosure..........................2-6 Figure 2.3: Connector Block for -48 Vdc Input ......................2-9 Figure 2.4: E5714 (1U) Encoder Rear Panel Component

    Parts and Connectors (mains supply) .................2-11 Figure 2.5: E5740-IF (2U) Encoder Rear Panel

    Component Parts and Connectors (mainssupply).................................................................2-11

    Figure 2.6: E5740-L-Band (2U) Encoder Rear PanelComponent Parts and Connectors (mainssupply).................................................................2-12

    Figure 2.7: E5750 (2U) Encoder Rear Panel ComponentParts and Connectors (mains supply) .................2-12

    Figure 2.8: E5714/E5740/E5750 SD EncoderConnections for the Basic Unit............................2-13

    Figure 2.9: E5784/E5788 HD Encoder Connections forthe Basic Unit ......................................................2-17

    List of TablesTable 2.1: Supply Cable Wiring Colours................................2-7 Table 2.2: IF Out (Main) Connector (E5714-IF and

    E5740 IF) .............................................................2-14 Table 2.3: IF Output (Monitor) Connector (E5714-IF and

    E5740 IF) .............................................................2-14 Table 2.4: L-band In Connector (E5740-LBAND and

    E5714-LBAND)....................................................2-14 Table 2.5: L-band Out (Main) Connector (E5740-LBAND

    and E5714-LBAND) .............................................2-15 Table 2.6: L-band Out (Monitor) Connector (E5740-

    LBAND and E5714-LBAND)................................2-15 Table 2.7: ASI Input.............................................................2-16 Table 2.8: IF Out 1 Connector (E5750) ...............................2-16 Table 2.9: IF Out 2 Connector (E5750) ...............................2-16 Table 2.10: IF Out (Main) Connector (E5784-IF/ E5788-

    IF) ........................................................................2-18 Table 2.11: IF Output (Monitor)Connector (E5784-IF/

    E5788-IF).............................................................2-18 Table 2.12: L-Band In Connector (E5784-LBAND/E5788-

    LBAND)................................................................2-18 Table 2.13: L-Band Out (Main) Connector (E5784-

    LBAND/E5788-LBAND).......................................2-19

    Table 2.14: L-Band Out (Monitor) Connector (E5784-LBAND/E5788-LBAND).......................................2-19

  • 8/11/2019 t and Berg Encoder Ref Guide

    25/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-3 ST.RE.VOY.E57xx.1

    2.1 Introduction

    2.1.1 Read This First!The Encoder must be handled carefully and thoughtfully to prevent safety hazards anddamage. It is usually supplied as part of a system installed by TANDBERG Television

    engineers. In any case, ensure the personnel designated to install the unit have theappropriate skills and knowledge. If in any doubt, contact Customer Services.

    Follow the instructions for installation and only use installation accessories recommended bythe manufacturers.

    2.1.2 GeneralInstallation of the Encoder is normally performed by TANDBERG Television personnel. Thischapter provides configuration and connection information for planning installations, checkingthe final set-up in the event of a fault, modifying the requirements or moving the equipment toanother location. In the event of problems, contact Customer Services.

    2.1.3 Site Requirements

    Power Supplies

    See Annex B, Technical Specification for a full specification.

    Environment

    See Annex B, Technical Specification for a full specification.

    Do not install this product in areas of high humidity or where there is danger of water ingress.

    Lightning Protection

    WARNINGIF THE ENCODER HAS BEEN SUBJECT TO A LIGHTNING STRIKE OR POWER SURGE WHICHHAS STOPPED IT WORKING, DISCONNECT THE POWER IMMEDIATELY. DO NOT REAPPLYPOWER UNTIL IT HAS BEEN CHECKED FOR SAFETY. IF IN DOUBT, CONTACT TANDBERG

    TELEVISION CUSTOMER SERVICES.

    Where appropriate, ensure this product has an adequate level of lightning protection. Alternatively, during a lightning storm or when it is left unattended and unused for long periodsof time, unplug it from the supply outlet and disconnect the output equipment. This preventsdamage to the product due to lightning and power line surges.

    2.1.4 EMC Compliance Statements 1

    EN 55022 / AS/NZS 3548

    This equipment is a Class A product. In a domestic environment this product may cause radiointerference in which case the user may be required to take adequate measures.

    FCC

    This equipment has been tested and found to comply with the limits for a Class A digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide

    reasonable protection against harmful interference when the equipment is operated in acommercial environment.

    1 The EMC information was correct at the time of manufacture. The EMC tests were performed with the Technical earth attached.

  • 8/11/2019 t and Berg Encoder Ref Guide

    26/186

    Installing the Equipment

    Page 2-4 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    This equipment generates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residential area is likely to cause harmfulinterference in which case the user will be required to correct the interference at his ownexpense.

    2.2 Preliminary Checks

    2.2.1 Mechanical InspectionWhen taking delivery of an Encoder, check the equipment items delivered against theenclosed delivery note. Inspect the equipment for damage in transit. If in doubt, contactCustomer Services (see Preliminary Pages ).

    NOTEDo not remove the covers of this equipment as doing so may invalidate any warranties, cause a safetyhazard and/or affect the EMC performance. It may also invalidate any safety tests. Check withCustomer Services beforehand.

    2.2.2 Moving the Equipment Safely

    Do not place this product on an unstable cart, stand, bracket, or table. Theproduct may fall, causing serious injury and serious damage to the product.Use only with a cart, stand, bracket or table recommended by TANDBERGTelevision.

    An appliance and cart combination should be moved with care. Quick stops, excessive force,and uneven surfaces may cause the appliance and cart combination to overturn.

    Do not move or carry the equipment whilst it is still connected to the supply or other leads, islive or is in operation.

    2.3 Installing the Equipment

    2.3.1 Fixing MethodThe Encoder can be operated mounted in a 19-inch rack. Ensure that it is firmly and safelylocated and has an adequate through-flow of air.

    Slide the Encoder onto the chassis supports and affix to the rack by means of an M6 x 18 mmpanhead screw in each corner (see Figure 2.1 ).

    Do not use this product as a support for any other equipment.

  • 8/11/2019 t and Berg Encoder Ref Guide

    27/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-5 ST.RE.VOY.E57xx.1

    Figure 2.1: Fitting the Encoder into a Rack (1U Encoder Shown)

    NOTECurrent versions are not fitted with the Standby switch shown above.

    2.3.2 Cable RoutingPower supply cables should be routed so that they are not likely to be walked on or pinchedby items placed upon or against them. Pay particular attention to cables at plugs, convenience

    receptacles, and the point where they exit from the appliance.Do not run ac power cables in the same duct as signal leads.

    2.3.3 Equipment Access

    WARNING...BERYLLIUM COPPER FINGER STRIPS ARE USED IN THIS EQUIPMENT TO SEAL THE

    ENCLOSURE FOR EMI PROTECTION. THIS ARRANGEMENT IS PERFECTLY SAFE DURINGNORMAL OPERATION. DO NOT FILE THE STRIPS OR OTHERWISE CAUSE THEM TO PRODUCE

    DUST OR PARTICLES. ANY CUTS CAUSED BY THE STRIP SHOULD BE TREATED APPROPRIATELY.

    Ensure that the Encoder is installed in such a way as to allow access to the rear of the unitand the connectors.

    2.3.4 Ventilation

    WARNING...NEVER PUSH OBJECTS OF ANY KIND INTO THIS EQUIPMENT THROUGH OPENINGS AS THEY

    MAY TOUCH DANGEROUS VOLTAGE POINTS OR SHORT-OUT PARTS THAT COULD RESULT IN A FIRE OR ELECTRIC SHOCK. NEVER SPILL LIQUID OF ANY KIND ON THE PRODUCT.

    CAUTIONS...1. Openings in the cabinet are provided for ventilation and to ensure reliable operation of the product

    and to protect it from overheating, and these openings must not be blocked or covered. This productshould never be placed near or over a radiator or heat register. This product should not be placed ina built-in installation such as a rack unless proper ventilation is provided or the instructions havebeen adhered to.

    2. Do not install equipment so that the air intake of one aligns with the outlet on another. Providebaffles and adequate spacing.

    3. The fans contained within this unit are not fitted with a dust/insect filter. Pay particular attention to theenvironment in which it is to be used.

    Location of screws to attachEncoder to rack.

    Same at the opposite side of the Encoder

  • 8/11/2019 t and Berg Encoder Ref Guide

    28/186

    Installing the Equipment

    Page 2-6 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    The unit is designed for stationary or fixed use only. Ensure it is firmly and safely located andhas an adequate through-flow of air. Allow at least 50 mm free air-space at each side of theequipment. Units in racks can be stacked without ventilation panels between. Rackscontaining stacked equipment may need to be forced-air cooled to reduce the operatingambient temperature. For stacking constraints contact Customer Services.

    The 1U Encoder uses a similar air-flow path, with three fans on each side of the unit. With

    both 1U and 2U units it is important not to block the front air intake on the bottom-left corner ofthe front panel (see Figure 2.2 ).

    1U Encoder Air-flow

    2U Encoder Air-flow

    Figure 2.2: Air Path Through the Enclosure

    NOTECooling arrangements in current models may differ to those shown.

    Warm air out

    Cool air in

    (front via bottom vent)

    Cool air in

    Warm air out

    (right)

    Cool air in

    (left)

  • 8/11/2019 t and Berg Encoder Ref Guide

    29/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-7 ST.RE.VOY.E57xx.1

    2.4 A.C. Mains Operating Voltage and Earthing

    2.4.1 A.C. Power Supply

    CAUTION...This product should be operated only from the type of power source indicated on the marking label. Ifyou are not sure of the type of power supply to your business, consult a qualified electrical engineer or

    your local power company.

    See Annex B, Technical Specification for a full power supply specification. There are no linksor switches to be altered for operation from different a.c. supplies.

    2.4.2 Power Cable and Earthing

    General

    Check that the a.c. power cable is suitable for the country in which the Encoder is to be used.

    WARNINGS...1. IF THE MOULDED PLUG FITTED TO THE MAINS CABLE SUPPLIED WITH THIS UNIT IS NOT

    REQUIRED, PLEASE DISPOSE OF IT SAFELY. FAILURE TO DO THIS MAY ENDANGER LIFE AS LIVE ENDS MAY BE EXPOSED IF THE REMOVED PLUG IS INSERTED INTO A MAINSOUTLET.

    2. POWER SUPPLY CORDS SHOULD BE ROUTED SO THAT THEY ARE NOT LIKELY TO BEWALKED ON OR PINCHED BY ITEMS PLACED UPON OR AGAINST THEM, PAYINGPARTICULAR ATTENTION TO CORDS AT PLUGS, CONVENIENCE RECEPTACLES, ANDTHE POINT WHERE THEY EXIT FROM THE APPLIANCE.

    The unit is supplied with three, detachable mains-supply cables fitted with moulded plugs

    suitable for the USA, UK or Europe.The wires in the mains cable are coloured in accordance with the wire colour code shown inTable 2.1 .

    Table 2.1: Supply Cable Wiring Colours

    UK(BS 1363)

    EUROPE(CEE 7/7)

    USA(NEMA 5-15P)

    Earth: Green-and-yellow Green-and-yellow Green

    Neutral: Blue Blue White

    Live: Brown Brown Black

    Protective Earth/Technical Earth

    WARNINGS...1. THIS UNIT MUST BE CORRECTLY EARTHED THROUGH THE MOULDED PLUG SUPPLIED.

    IF THE LOCAL MAINS SUPPLY DOES NOT HAVE AN EARTH CONDUCTOR DO NOTCONNECT THE UNIT. CONTACT CUSTOMER SERVICES FOR ADVICE.

    2. BEFORE CONNECTING THE UNIT TO THE SUPPLY, CHECK THE SUPPLY REQUIREMENTSIN ANNEX B.

    The unit has a Technical earth terminal (marked with ) located at the rear panel. Its use isrecommended. This is NOT a Protective earth for electric shock protection. The terminal isprovided to:

  • 8/11/2019 t and Berg Encoder Ref Guide

    30/186

    Installing the Equipment

    Page 2-8 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    1. Ensure all equipment chassis fixed within a rack are at the same Technical earthpotential. To do this, connect a wire between the Technical earth terminal and a suitablepoint on the rack.

    2. Eliminate the migration of stray charges when connecting between equipment.

    WARNING...

    IF THE TERMINAL SCREW HAS TO BE REPLACED, USE THE FOLLOWING:1U ENCODER - M4 X 10 mm LONG POZIDRIV PANHEAD.2U ENCODER - M5 X 12mm LONG POZIDRIV PANHEAD.

    USING A LONGER SCREW MAY CAUSE A SAFETY HAZARD.

    Connecting the Encoder to the A.C. Power Supply

    WARNINGS...1. DO NOT OVERLOAD WALL OUTLETS AND EXTENSION CORDS AS THIS CAN RESULT IN A

    RISK OF FIRE OR ELECTRIC SHOCK.

    2. AS NO MAINS SWITCH IS FITTED TO THIS UNIT, ENSURE THE LOCAL AC POWER SUPPLYIS SWITCHED OFF BEFORE CONNECTING THE SUPPLY CORD.

    3. THE ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. ENSURE THAT THE SOCKET-OUTLET IS INSTALLED NEAR THE EQUIPMENT SO THAT IT IS EASILY ACCESSIBLE.FAILURE TO ISOLATE THE EQUIPMENT PROPERLY MAY CAUSE A SAFETY HAZARD.

    To connect the unit to the local a.c. power supply:

    1. Ensure the local a.c. supply is switched OFF.

    2. Ensure the correct fuse type and rating has been fitted to both the equipment and the a.c.power cable.

    3. Connect the a.c. power lead to the Encoder mains input connector and then to the localmains supply.

  • 8/11/2019 t and Berg Encoder Ref Guide

    31/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-9 ST.RE.VOY.E57xx.1

    2.5 -48 Vdc Power Supply

    2.5.1 D.C. Power Supply

    NOTE

    Only model M2/VOY/E5750/48V uses a d.c. power supply.

    CAUTIONS...1. This product should be operated only from the type of power source indicated on the marking label.

    If you are not sure of the type of power supply to your business, consult a qualified electricalengineer.

    2. This equipment is Class 1 and must have a protective earth.

    This product uses a 48 Vdc power supply source (see Annex B, Technical Specification for afull power supply specification.

    For wiring d.c. power a minimum wire size of 1.0mm 2 (17AWG) is recommended. This mayneed to be increased for longer cable runs. For protection of the d.c. wiring a circuit breaker ofmaximum 10A is recommended.

    2.5.2 Location of the D.C. Input ConnectorThe connector is located at the right-hand rear of the equipment.

    WARNINGTHE 48 VDC ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. ENSURE THAT THE SUPPLY

    HAS A SUITABLE MEANS OF ISOLATION WHICH IS EASILY ACCESSIBLE. FAILURE TOISOLATE THE EQUIPMENT PROPERLY MAY CAUSE A SAFETY HAZARD.

    Figure 2.3: Connector Block for -48 Vdc Input

    +

    Technical Earth

    Fuse Carrier

    Connector Block

    1U Encoder

    2U Encoder

    Technical Earth

    Supply Side

    Equipment Side +

    Connector Block

    Fuse6.3A

    48 V 0 V

  • 8/11/2019 t and Berg Encoder Ref Guide

    32/186

    Installing the Equipment

    Page 2-10 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    The equipment fuse is held in an integral fuse carrier at the dc power inlet at the rear of theEncoder. See Annex B, Technical Specification for d.c. fuse information.

    2.5.3 Connecting the Equipment to the D.C. Power Supply

    NOTE

    This equipment is not intended for direct connection to centralised dc power systems in the USA orCanada.

    Connect the Encoder to the local d.c. power supply as follows.

    1. Local D.C. Power Supply Ensure the local d.c. supply is isolated.

    2. Encoder Ensure the correct fuse is fitted.

    3. Supply Cord Connect the d.c. lead to the Encoder input connector and then to the local d.c. power

    supply. Switch on the d.c. power supply.

    2.5.4 Technical EarthThe unit has a Technical earth terminal (marked with ) located at the rear panel (see Figure 2.3 ). Its use is recommended. This is NOT a Protective earth for electric shockprotection. The terminal is provided to: Ensure all equipment chassis fixed within a rack are at the same Technical earth

    potential. To do this, connect a wire between the Technical earth terminal and a suitablepoint on the rack.

    Eliminate the migration of stray charges when connecting between equipment.

    WARNING...IF THE TERMINAL SCREW HAS TO BE REPLACED, USE THE FOLLOWING:

    1U ENCODER - M4 X 10 mm LONG POZIDRIV PANHEAD.2U ENCODER - M5 X 12mm LONG POZIDRIV PANHEAD.

    USING A LONGER SCREW MAY CAUSE A SAFETY HAZARD.

  • 8/11/2019 t and Berg Encoder Ref Guide

    33/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-11 ST.RE.VOY.E57xx.1

    2.6 Signal Connections E5714/E5740/E5750 SD Encoders

    2.6.1 Introduction

    Connection of Antennae

    The RF outputs of these Encoders are not intended for direct connection to an externalantenna. An appropriate up-converter must be used.

    Cables

    Always use the specified cables supplied for signal integrity and compliance with EMCrequirements (see Annex B, Technical Specification ).

    2.6.2 Rear Panel Connections All signal connectors are located at the rear panel of the Encoder. For a detailed interfacespecification see Annex B, Technical Specification .

    For further details of the Encoder connections, refer to the associated Reference Guideindicated in Chapter 1, Table 1.1 .

    Figure 2.4: E5714 (1U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    Figure 2.5: E5740-IF (2U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    Option Slot 2

    Audio Inand

    Audio Reference Out

    H Sync CompositeVideo

    ASI OutputsEthernetRS-232Data

    RS-422Data

    Alarm RS-232/ RS-485Remote Control

    SDI In

    Base Board

    Technical EarthIF Out Main IF Out Monitor

    Technical Earth

    Option Slot 1

    Option Slot Option Slot 5 Option Slot 6

    Option Slot 1

    Audio Inand

    Audio Reference OutComposite

    Video

    ASIOutputs

    Alarm

    RS-232/RS-485Remote Control

    SDI InEthernet

    Option Slots 4-6

    Base Board

    IF OutMain

    IF OutMonitor

    TANDBERGTelevision use

    only

    H Sync

    RS-232Data

    RS-422Data

  • 8/11/2019 t and Berg Encoder Ref Guide

    34/186

    Installing the Equipment

    Page 2-12 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    Figure 2.6: E5740-L-Band (2U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    Figure 2.7: E5750 (2U) Encoder Rear Panel Component Parts and Connectors (mains supply)

    2.6.3 Connecting Up the Basic E5714/E5740/E5750 SD EncoderOnce the unit has been installed in its intended operating position, it is ready to be connectedup to the rest of the system equipment(see Figure 2.8 ), providing it too has been installed (see the following for pin-out details of theconnectors).

    TANDBERGTelevision use

    only

    Option Slots 4-6

    TechnicalEarth

    Option Slot 1

    Option Slot 4 Option Slot Option Slot 6

    Option Slot 1

    Audio Inand

    Audio Reference OutComposite

    Video

    ASIOutputs

    Alarm

    RS-232/RS-485Remote Control

    SDI InEthernet

    Base Board

    L-Band In L-Band Out

    H Sync

    RS-232Data

    RS-422Data

    TechnicalEarth

    Option Slot 1

    Option Slot 4 Option Slot

    Option Slot 1

    Audio Inand

    Audio Reference OutComposite

    Video

    ASIOutputs

    Alarm

    RS-232/RS-485Remote Control

    SDI InEthernet

    Option Slots 4-5

    Base Board

    H Sync

    RS-232Data

    RS-422Data

    Option Slot 2 Option Slot 3

  • 8/11/2019 t and Berg Encoder Ref Guide

    35/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-13 ST.RE.VOY.E57xx.1

    Figure 2.8: E5714/E5740/E5750 SD Encoder Connections for the Basic Unit

    Do not move or install equipment whilst it is still attached to the mains supply. Ensure ESDprecautions are observed whilst interconnecting equipment.

    NOTESee Chapter 3 for information relating to Options and Upgrades.

    E5714/E5740/E5750 Encoder

    Video Input

    SDI INH SYNC

    COMP VIDEO

    Audio input

    AES/EBU Reference

    ETHERNET #1

    ETHERNET #2

    REMOTE CONTROL

    Audio Input

    Control

    RS-232 data input

    RS-422 data input

    Alarm and Fail Monitoring

    DVB/ATSC Transport stream

    DVB/ATSC Transport stream

    DVB/ATSC Transport stream

    Output

    Alarm

    ASI OUT 1

    ASI OUT 2

    ASI OUT 3

    ALARM

    10BaseT

    10BaseT

    RS-232/RS-485

    AUDIO IN

    Serial Digital Interface

    Analogue composite video

    Studio Black and Burst

    Data

    RS-232 DATA

    RS-422 DATA

    IF Main Output

    Modulator (IF)[E5740-IF]

    IF OUT MAIN

    IF OUT MONITOR IF Monitor Output

    L-Band In

    Modulator (L-band)[E5740-L Band]

    L-BAND IN

    L-BAND OUT MAIN

    L-BAND OUTMONITOR

    L-Band Monitor Output

    L-Band Main Output

    IF Main Output

    Modulator[E5714]

    IF OUT MAIN

    IF OUT MONITOR IF Monitor Output

    70 MHz COFDM Output 1

    70 MHz COFDM Output 2

    Modulator (OFDM)[E5750]

    IF OUT 1

    IF OUT 2

  • 8/11/2019 t and Berg Encoder Ref Guide

    36/186

    Installing the Equipment

    Page 2-14 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    2.6.4 Satellite Modulator IF Output (E5714-IF and E5740 IF)

    IF Out (Main)

    75 BNC socket provides an IF output.

    Table 2.2: IF Out (Main) Connector (E5714-IF and E5740 IF)

    Item Specification

    Connector type BNC 75 Female

    Type Analogue

    Connector designation IF OUT MAIN

    Pin-outs CentreScreen

    IF OutputGround

    IF Out (Monitor)

    75 BNC socket provides an IF output used for monitoring.

    Table 2.3: IF Output (Monitor) Connector (E5714-IF and E5740 IF)

    Item Specification

    Connector type BNC 75 Female

    Type Analogue

    Connector designations IF OUT MONITOR

    Pin-outs CentreScreen

    IF OutputGround

    2.6.5 Satellite Modulator L-Band Output (E5740-LBAND andE5714-LBAND)

    L-Band In

    50 SMA female connector provides an L-band input to allow anotherL-band signal to be summed with the modulator output.

    CAUTIONDo not connect large diameter cable to the SMA connector as this may cause mechanical damage.

    Table 2.4: L-band In Connector (E5740-LBAND and E5714-LBAND)

    Item Specification

    Connector Type 50 SMA Female

    Type Analogue

    Connector designation L-Band In

    Pin-outs Centre Signal

    Screen Ground

  • 8/11/2019 t and Berg Encoder Ref Guide

    37/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-15 ST.RE.VOY.E57xx.1

    L-Band Out (Main)

    50 SMA female connector provides the main L-band output. Bothmodels can provide a 10 MHz reference frequency output and theE5740 can also source +24 Vdc at up to 500 mA to power a blockup-converter (BUC) An LED is illuminated when the +24 Vdcup-converter power is switched on.

    CAUTIONDo not connect large diameter cable to the SMA connector as this mat cause mechanical damage.

    Please use the cable provided (part number S12696).

    NOTED.C. supply not available in 1U L Band version.

    Table 2.5: L-band Out (Main) Connector (E5740-LBAND and E5714-LBAND)

    Item Specification

    Connector Type 50 SMA Female

    Type Analogue

    Connector designation L-Band Out Main

    Pin-outs Centre Signal

    Screen Ground

    CAUTION A 24 Vdc voltage is present at the L-BAND OUT MAIN connector when the up-converter d.c. power is

    switched on. Do not connect this output directly to a spectrum analyser or other sensitive equipment.The use of a d.c. block is recommended.

    L-Band Out (Monitor)

    75 F-type female provides an L-band monitoring output which is 30 dB relative to the main output.

    Table 2.6: L-band Out (Monitor) Connector (E5740-LBAND and E5714-LBAND)

    Item Specification

    Connector Type 75 F-type Female

    Type Analogue

    Connector designation L-Band Out Monitor

    Pin-outs Centre Signal

    Screen Ground

    ASI Input

    This connector is available with the following models:E5740-IF and L-Band, and the E5714 L-band (when fitted with the S13716/S13719).

    Connector details for the ASI input are given in Table 2.7.

  • 8/11/2019 t and Berg Encoder Ref Guide

    38/186

    Installing the Equipment

    Page 2-16 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    Table 2.7: ASI Input

    Item Specification

    Connector Type 75 BNC Female

    Type Analogue

    Connector designation ASI IN 1, ASI IN 2

    Pin-outs Centre Signal

    Screen Ground

    2.6.6 OFDM Modulator Outputs (E5750)

    IF Out 1

    A 75 BNC socket provides a 70 MHz IF output.

    Table 2.8: IF Out 1 Connector (E5750)

    Item SpecificationConnector Type BNC 75 Female

    Type Analogue

    Connector designation IF Out 1

    Pin-outs Centre Signal

    Screen Ground

    IF Out 2

    A 75 BNC socket provides a 70 MHz IF output used for monitoring.

    Table 2.9: IF Out 2 Connector (E5750)

    Item Specification

    Connector Type BNC 75 Female

    Type Analogue

    Connector designation IF Out 2

    Pin-outs Centre Signal

    Screen Ground

  • 8/11/2019 t and Berg Encoder Ref Guide

    39/186

    Installing the Equipment

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 2-17 ST.RE.VOY.E57xx.1

    2.7 Signal Connections E5784/E5788 HD Encoders

    2.7.1 GeneralFor further details of the Encoder connections, refer to the associated Reference Guideindicated in Chapter 1, Table 1.1 .

    2.7.2 IntroductionOnce the unit has been installed in its intended operating position, it is ready to be connectedup to the rest of the system equipment (see Figure 2.8 ), providing it too has been installed(see Section 2.5, Figure 2.8 for pin-out details of the connectors).

    Figure 2.9: E5784/E5788 HD Encoder Connections for the Basic Unit

    Do not move or install equipment whilst it is still attached to the mains supply. Ensure ESDprecautions are observed whilst interconnecting equipment.

    NOTESee Chapter 3 for information relating to Options and Upgrades.

    E5784/E5788 Encoder

    Video Input

    SDI IN

    HD SDI IN

    H SYNC

    COMP VIDEO

    Audio input

    AES/EBU Reference

    ETHERNET #1

    ETHERNET #2

    REMOTE CONTROL

    Audio Input

    Control

    RS-232 data input

    RS-422 data input

    Alarm and Monitoring

    DVB/ATSC Transport stream

    Output

    Alarm

    ASI OUT 1

    ASI OUT 2

    ASI OUT 3

    ALARM

    10BaseT

    10BaseT

    RS-232/RS-485

    AUDIO IN

    DVB/ATSC Transport stream

    DVB/ATSC Transport stream

    SD Serial Digital Interface

    Analogue composite video

    Studio Black and Burst

    Data

    RS-232 DATA

    RS-422 DATA

    HD Serial Digital Interface

    Main Output

    Modulator (IF)

    OUT MAIN

    OUT MONITOR Monitor Output

    L-Band In

    Modulator (L-band)

    L-BAND IN

    L-BAND OUT MAIN

    L-BAND OUTMONITOR

    L-Band Monitor Output

    L-Band Main Output

  • 8/11/2019 t and Berg Encoder Ref Guide

    40/186

    Installing the Equipment

    Page 2-18 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    2.7.3 Satellite Modulator IF Output (E5784-IF/E5788-IF)

    IF Out (Main)

    75 BNC socket provides an IF output.

    Table 2.10: IF Out (Main) Connector (E5784-IF/ E5788-IF)

    Item Specification

    Connector type BNC 75 Female

    Type Analogue

    Connector designation IF OUT MAIN

    Pin-outs CentreScreen

    IF OutputGround

    IF Out (Monitor)

    75 BNC socket provides an IF output used for monitoring.

    Table 2.11: IF Output (Monitor)Connector (E5784-IF/ E5788-IF)

    Item Specification

    Connector type BNC 75 Female

    Type Analogue

    Connector designations IF OUT MONITOR

    Pin-outs CentreScreen

    IF OutputGround

    2.7.4 Satellite Modulator L-Band Output(E5784-LBAND/E5788-LBAND)

    L-Band In

    50 SMA female connector provides an L-band input to allow anotherL-band signal to be summed with the modulator output.

    Table 2.12: L-Band In Connector (E5784-LBAND/E5788-LBAND)

    Item Specification

    Connector Type 50 SMA FemaleType Analogue

    Connector designation L-Band In

    Pin-outs Centre Signal

    Screen Ground

  • 8/11/2019 t and Berg Encoder Ref Guide

    41/186

  • 8/11/2019 t and Berg Encoder Ref Guide

    42/186

    Installing the Equipment

    Page 2-20 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    BLANK

  • 8/11/2019 t and Berg Encoder Ref Guide

    43/186

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 3-1 ST.RE.VOY.E57xx.1

    Chapter 33. Options and Upgrades

    Contents3.1 How to See Which Options are

    Fitted/Enabled................................................... 3-5

    3.2 Use of Option Modules in Basic Encoders ........ 3-5 3.2.1 Options Fitted as Standard .................... 3-5 3.2.2 Available Option Slots....... ..................... 3-5

    3.3 E5714/E5740/E5750 SD Option Functions ....... 3-7

    3.4 E5784/E5788 HD Option Functions .................. 3-9

    3.5 Options to Support Third-Party Equipment......3-10 3.6 Option Modules Limitations ............................. 3-11

    3.6.1 Limitations on the Number of OptionModules ............................................... 3-11

    3.6.2 Limitations on the Use of OptionModules ............................................... 3-11 Conditional Access ..............................3-11 Advanced Audio Option Module(M2/EOM2/ADVAUD) .......................... 3-11 Dual GigE IP NIC Option Module(M2/EOM2/IPTSDUAL)........................ 3-11 E5714 1U SD Encoder......................... 3-11

    3.7 Bit-rate Limits With Reflex Licence and/orPerformance Upgrade.......... ........................... 3-11

    3.8 Basic Interoperable Scrambling System -BISS (M2/EDCOM2/BISS).............................. 3-12

    3.9 Additional Audio and Linear PCM Option(M2/EOM2/AUDLIN2) ..................................... 3-12 3.9.1 Overview........ ...................................... 3-12 3.9.2 Assembly ............................................. 3-13

    Rear Panel........................................... 3-13 Audio In Connector .............................. 3-13

    3.10 ATM Network Interface Option Module(M2/EOM2/ATMS155_)............................... 3-15 3.10.1 Overview........ ...................................... 3-15 3.10.2 Assembly ............................................. 3-15

    3.10.3 Common Connectors ...........................3-15 DVB-ASI Copper Input .........................3-15 DVB-ASI Copper Output ......................3-16 10BaseT Ethernet Connector...............3-16

    3.10.4 Technical Specification ........................3-16 Variants of The ATM NetworkInterface Module ..................................3-16 DVB-ASI Copper Output ......................3-17 DVB-ASI Copper Input .........................3-17

    10BaseT Ethernet Connector...............3-17

    Multi-mode Fibre Optic Connector .......3-17 Monomode Fibre Optic Connector .......3-18 M2/EOM2/ATMS34 PDH/E3Connector ............................................ 3-19 M2/EOM2ATMS45 PDH/DS3Connector ............................................ 3-20 M2/EOM2ATMS155E STM-1Electrical Module..................................3-21

    3.11 Advanced Audio Coding Option(M2/EOM2/ADVAUD)......................................3-22 3.11.1 Overview .............................................. 3-22 3.11.2 Assembly ............................................. 3-22

    Rear Panel ........................................... 3-22 AES x Connector..................................3-22 AES REF Connector ............................3-23

    3.12 GPI Card (M2/EOM2/GPI)...............................3-24 3.12.1 Overview .............................................. 3-24 3.12.2 Assembly (1U Panel Version Shown) ..3-24 3.12.3 Connector ............................................ 3-24 3.12.4 Technical Specification ........................3-25

    3.13 G.703 Interface Card Option(M2/EOM2/G703) ............................................ 3-25 3.13.1 Overview .............................................. 3-25 3.13.2 Assembly ............................................. 3-25

    Rear Panel ........................................... 3-25 OUT Connector....................................3-26

  • 8/11/2019 t and Berg Encoder Ref Guide

    44/186

    Options and Upgrades

    Page 3-2 Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 EncodersST.RE.VOY.E57xx.1

    IN Connector........................................3-26 RS-232 Connector ...............................3-26

    3.14 IP Output Card (M2/EOM2/IP) IP CardProMPEG FEC (M2/EOM2/IP/PROFEC) ........3-27 3.14.1 Overview .............................................. 3-27 3.14.2 Support for ProMPEG FEC................ ..3-27 3.14.3 Smallcasting Mode...............................3-27 3.14.4 Assembly ............................................. 3-28

    Rear Panel ........................................... 3-28 ASI In ................................................... 3-28 RS-232 Control ....................................3-28 ASI Out ................................................ 3-28 Ethernet Output....................................3-29

    3.14.5 Technical Specification.........................3-29

    3.15 Multi-pass Encoder Card (M2/EOM2/MPM) ....3-29

    3.16 PDH/DS3 Module (M2/EOM2/ATMS45)..........3-30 3.16.1 Assembly ............................................. 3-30 3.16.2 Connectors...........................................3-30 3.16.3 Technical Specification.........................3-31

    3.17 PDH/E3 Module (M2/EOM2/ATMS34) ............3-32 3.17.1 Assembly ............................................. 3-32 3.17.2 Connectors...........................................3-32 3.17.3 Technical Specification.........................3-33

    3.18 QPSK Demodulator(M2/EOM2/QPSKDEMOD)..............................3-34 3.18.1 Overview .............................................. 3-34 3.18.2 Assembly ............................................. 3-34

    Rear Panel ........................................... 3-34 IF In......................................................3-34 RF In .................................................... 3-34 ASI In ................................................... 3-35

    3.18.3 Technical Specification.........................3-35

    3.19 Remux Option (M2/EOM2/REMUX)................3-36 3.19.1 Overview .............................................. 3-36 3.19.2 Assembly ............................................. 3-36

    Rear Panel ........................................... 3-36 DVB ASI IN 1, 2 and 3 Connectors ......3-37 DVB ASI OUT 1 Connector..................3-37

    3.19.3 Stages of Re-multiplexing ....................3-38 3.19.4 Function of Remultiplexer.....................3-39

    3.19.5 Using the Remultiplexer .......................3-40 3.19.6 ATSC Re-multiplexing..........................3-41 3.19.7 Setting Bit-rates and Avoiding

    Overflow...............................................3-41 3.19.8 Technical Specification.........................3-41

    Connectors...........................................3-41 LEDs .................................................... 3-42

    3.19.9 What to do if Overflow Occurs..............3-43

    3.20 SD Decoder Option (M2/EOM2/DEC) .............3-44 3.20.1 Overview .............................................. 3-44 3.20.2 Assembly ............................................. 3-44

    Rear Panel ........................................... 3-44 ASI Out ................................................ 3-44 SDI Video Out ......................................3-44 Composite Video Output ......................3-45

    Audio Output ........................................3-45 RS-232/RS-422 Data Output................3-46

    3.21 SMPTE 310 (SSI) and ASI Optical OutputsOption Modules (M2/EOM2/ASI-OPT) and(M2/EOM2/SSI-US) .........................................3-47 3.21.1 Overview ..............................................3-47 3.21.2 Assembly..............................................3-47

    Rear Panel ...........................................3-47 SMPTE 310 1, 2 and 3 Connectors......3-48 ASI OUT 1, 2 Connectors.....................3-48

    3.21.3 Technical Specification.........................3-48 M2/EOM2/ASI-OPT, ASI OutputOption Module ......................................3-48 M2/EOM2/SSI-US, SMPTE 310 (SSI)Optical Output Option Module ..............3-49

    3.22 STM-1 Electrical Module(M2/EOM2/ATMS155E)...................................3-50 3.22.1 Assembly..............................................3-50 3.22.2 Connectors...........................................3-50

    3.23 STM-1 OC3 Multi-mode Physical InterfaceModule (M2/EOM2/ATMS155MM)...................3-51 3.23.1 Assembly..............................................3-51 3.23.2 Multi-mode Fibre Optic Connector........3-51

    3.24 STM-1 OC3 Monomode Physical InterfaceModule (M2/EOM2/ATMS155SM)...................3-53 3.24.1 Assembly..............................................3-53 3.24.2 Monomode Fibre Optic Connector .......3-53

    3.25 Triax Option (M2/EOM2/TRIAX)......................3-55 3.25.1 Introduction...........................................3-55 3.25.2 Description ...........................................3-55 3.25.3 Technical Specification.........................3-55

    3.26 Vocality Card Option(M2/EOM2/COMMS/FXS andM2/EOM2/COMMS/FXO) ................................3-56 3.26.1 Overview ..............................................3-56 3.26.2 Assembly..............................................3-57

    Rear Panel ...........................................3-57 Telephone Line Connectors .................3-57 Data Connector ....................................3-58 Supervisor Port Connector ...................3-58 Link Connector .....................................3-59

    LAN Connector.....................................3-59

    3.26.3 Connecting the DSNGCommunications Card to the Encoder..3-60

    3.26.4 Configuring the Encoder for theDSNG Communications Card...............3-60

    3.26.5 Technical Specification.........................3-60

    3.27 16QAM Demodulator(M2/EOM2/SATDEMOD).................................3-62 3.27.1 Overview ..............................................3-62 3.27.2 Assembly..............................................3-62

    Rear Panel ...........................................3-62 L-Band Inputs .......................................3-62

    3.27.3 Technical Specification.........................3-62 3.28 GigaSat Baseband Multiplexer Option

    Module.............................................................3-63

  • 8/11/2019 t and Berg Encoder Ref Guide

    45/186

    Options and Upgrades

    Reference Guide: E5714/E5740-xxx DSNG, E5750 DENG, E5784 HD DSNG and E5788 Encoders Page 3-3ST.RE.VOY.E57xx.1

    3.28.1 Product Description.............................. 3-63 3.28.2 Fitting ................................................... 3-63 3.28.3 Menu....... ............................................. 3-64

    3.29 E2V Stellar N63 Series HPA ........................... 3-66 3.29.1 Product Description.............................. 3-66 3.29.2 Menu....... ............................................. 3-66

    List of FiguresFigure 3.1: E5714-IF Option Slots.........................................3-5 Figure 3.2: E5714-LBAND Option Slots ................................3-6 Figure 3.3: E5740 SD Encoder Option Slots .........................3-6 Figure 3.4: E5750 SD Encoder Option Slots .........................3-6 Figure 3.5: E5784 HD Encoder Option Slots.........................3-6 Figure 3.6: E5788 HD Encoder Option Slots.........................3-6 Figure 3.7: Additional Audio and Linear PCM Option

    (M2/EOM2/AUDLIN2)..........................................3-13 Figure 3.8: Advanced Audio Coding Option

    (M2/EOM2/ADVAUD) ..........................................3-22 Figure 3.9: General Purpose Interface M2/EOM2/GPI........3-24 Figure 3.10: G.703 Interface Card Option

    M2/EOM2/G703...................................................3-25 Figure 3.11: IP Output Protocol Stack.................................3-27 Figure 3.12: Rear Panel Connectors

    (M2/EOM2/ATMS45 ATM PDH/DS3 Module)..... 3-30 Figure 3.13: Rear Panel Connectors

    (M2/EOM2/ATMS34 ATM PDH/E3 Module)........3-32 Figure 3.14: Remux Option (M2/EOM2/REMUX)................3-37 Figure 3.15: Block Diagram One Stage of Re-

    multiplexing..........................................................3-38 Figure 3.16: Block Diagram Two Stages of Re-

    multiplexing..........................................................3-39 Figure 3.17: Remultiplexer Block Diagram ..........................3-40 Figure 3.18: SMPTE 310 (SSI) and ASI Optical Outputs

    Option Modules (M2/EOM2/ASI-OPT) and(M2/EOM2/SSI-US) .............................................3-47 Figure 3.19: Rear Panel Connectors

    (M2/EOM2/ATMS155E ATM STM-1 ElectricalModule)................................................................3-50

    Figure 3.20: ATM Network Interface Module, Multi-modeOptical (M2/EOM2/ATMS155MM).......................3-51

    Figure 3.21: ATM Network Interface Module, MonomodeOptical (M2/EOM2/ATMS155SM) .......................3-53

    Figure 3.22: DSNG Comms Card Interconnections ............3-56 Figure 3.23: Vocality Card Option

    (M2/EOM2/COMMS/FXS andM2/EOM2/COMMS/FXO)....................................3-57

    Figure 3.24: DSNG Comms Card Connections...................3-60 Figure 3.25: E5784 HD Encoder Option Slot 6....................3-63 Figure 3.26: GigaSat Baseband Multiplexer Menu

    Location...............................................................3-64 Figure 3.27: Serial Menu Remote Control ...........................3-67

    List of TablesTable 3.1: Standard Cards ....................................................3-5 Table 3.2: E5714/E5740/E5750 SD Hardware Option

    Module Positions...................................................3-7 Table 3.3: E5714/E5740/E5750 SD Software Options..........3-8 Table 3.4: E5784/E5788 Hardware Option Module

    Positions................................................................3-9 Table 3.5: E5784/E5788 Software Options .........................3-10

    Table 3.6: Options to Support Third-Party Equipment.........3-10

    Table 3.7: Minimum Bit-rates With and WithoutPerformance Upgrade .........................................3-11

    Table 3.8: Audio In Connector.............................................3-13

    Table 3.9: DVB-ASI Copper Input Connector........... ....... ...... 3-15 Table 3.10: DVB-ASI Copper Output Connector ....... ....... ..... 3-16 Table 3.11: Ethernet Connector.......................................... 3-16 Table 3.12: B-ISDN Networks Supported........................... 3-16 Table 3.13: DVB Copper Output Connection...................... 3-17 Table 3.14: DVB Copper Input Connection......................... 3-17 Table 3.15: Ethernet Connector.......................................... 3-17 Table 3.16: Multi-mode Fibre Optic Connector................... 3-18 Table 3.17: Monomode Fibre Optic Connector................... 3-18 Table 3.18: E3 Input Connector .......................................... 3-19 Table 3.19: E3 Output Connector ....................................... 3-19 Table 3.20: DS3, G.703 Input Conn