190-531 SYSTEM OF NARCOTICS IDENTIFICATION 13386 International Parkway Jacksonville, Florida 32218 904.485.1836 FAX: 904.741.5407 INSTRUCTIONS FOR USE TEST L FOR: Heroin (Mecke Modified) Test Function 1. This reagent system presumptively identifies all forms of Heroin, including brown and black tar and Ecstasy (MDMA). How to Use Test L 1. Remove clip and insert into the test pack an amount of powdered suspect material that would fit inside this circle. Reseal with clip and tap gently to assure material falls to the bottom of the pouch. 2. With the printed side of the test pack facing you, break the ampules from left to right. Break by squeezing the center of the ampule with the tips of the thumb and forefinger. 3. Break the left ampule. Agitate gently for one minute. No color is expected at this step. Should a purple color develop, this indicates the presence of Ecstasy (MDMA). 4. Break right ampule and agitate gently. An immediate green color indicates the presence of Heroin. Interpretation of Resulting Colors 1. Due to the possible existence of various dyes in certain types of Heroin, the first ampoule may show various colors. If purple appears, this is a confirming color for the presence of Ecstasy (MDMA). 2. Heroin is confirmed in the second ampoule by a green color which will intensify with prolonged agitiation. Ecstasy colors in the second ampoule may vary. 3. In the absence of dyes with the first ampoule, the detection of Heroin within this test may be presumptively verified by Test A. CAUTION A. Since these tests contain strong acids, it is suggested that Test F - Acid Neutralizer be used after testing and before disposal. B. Before discarding used test packs, remove clip and add one measure of acid neutralizer from Test F. C. Add slowly to prevent bubbling over. D. DO NOT reseal the test pouch until effervescence has completely stopped. E. Reseal pouch with clip and discard in a tamper-free disposal unit. F. No attempt should be made to crush the glass particles after the ampoules are broken. G. Antidote: In case of contact, immediately flush eyes or skin with water for at least 15 minutes while removing contaminated clothing and shoes. If swallowed, do not give emetics. Contact a physician. WARNING These tests are NOT designed for use with liquid samples.

Transcript of SYSTÈME D’ SYSTEM OF IDENTIFICATION ... - Tiger Officer

Page 1: SYSTÈME D’ SYSTEM OF IDENTIFICATION ... - Tiger Officer

190-531

SYSTEM OFNARCOTICS

IDENTIFICATION

13386 International ParkwayJacksonville, Florida 32218904.485.1836 FAX: 904.741.5407

SYSTÈME D’IDENTIFICATION

DE NARCOTIQUES

13386 International ParkwayJacksonville, Florida 32218904.485.1836 FAX: 904.741.5407

INSTRUCTIONS FOR USE

TEST LFOR: Heroin(MeckeModified)Test Function1. This reagent system presumptively identifies all forms of

Heroin,includingbrownandblacktarandEcstasy(MDMA).How to Use Test L1. Remove clip and insert into the test pack an amount of

powderedsuspectmaterialthatwouldfitinsidethiscircle.Resealwithclipandtapgentlytoassurematerialfallstothebottomofthepouch.

2. Withtheprintedsideofthetestpackfacingyou,breaktheampulesfromlefttoright.Breakbysqueezingthecenteroftheampulewiththetipsofthethumbandforefinger.

3. Break the left ampule. Agitate gently for one minute. Nocolorisexpectedatthisstep.Shouldapurplecolordevelop,thisindicatesthepresenceofEcstasy(MDMA).

4. Breakrightampuleandagitategently.AnimmediategreencolorindicatesthepresenceofHeroin.

Interpretation of Resulting Colors1. Duetothepossibleexistenceofvariousdyesincertaintypes

of Heroin, the first ampoule may show various colors. Ifpurpleappears,thisisaconfirmingcolorforthepresenceofEcstasy(MDMA).

2. Heroinisconfirmedinthesecondampoulebyagreencolorwhichwillintensifywithprolongedagitiation.Ecstasycolorsinthesecondampoulemayvary.

3. Intheabsenceofdyeswiththefirstampoule,thedetectionofHeroinwithinthistestmaybepresumptivelyverifiedbyTestA.

CAUTIONA. Sincethesetestscontainstrongacids,itissuggestedthatTest

F-AcidNeutralizerbeusedaftertestingandbeforedisposal.B. Before discarding used test packs, remove clip and add one

measureofacidneutralizerfromTestF.C. Addslowlytopreventbubblingover.D. DONOTresealthetestpouchuntileffervescencehascompletely

stopped.E. Reseal pouch with clip and discard in a tamper-free disposal

unit.F. Noattemptshouldbemadetocrushtheglassparticlesafterthe

ampoulesarebroken.G. Antidote:Incaseofcontact,immediatelyflusheyesorskinwith

water for at least 15 minutes while removing contaminatedclothingandshoes.Ifswallowed,donotgiveemetics.Contactaphysician.

WARNINGThesetestsareNOTdesignedforusewithliquidsamples.

MODE D’ EMPLOI

TEST LPOUR:héroïne(meckemodifié)But du test1. Ce réactif indique la prèsence éventuelle de toutes les formes

d’héroïne,ycomprisl’héroïnebrune.l’héroïnenoiretype«goudron»etl’«Ecstasy»(méthylènedioxyméthamphétamine).

Méthode d’utilisation du test L1. Retirer la pince et introduire dans Ie sachet d’essai une quantité

deproduitsuspectpulvérisééquivalenteàcellequepeutcontenirI’intérieur du cercle ci-contre. Remettre la pince et fairetomberleproduitaufonddusachetenletapotentlégérement.

2. Tenirlesachetd’essaicòtéimpriméfaceàsoietcasserlesampoulesdegaucheàdroiteenécrasantleurpartiecentraleentrelepouceetl’index.

3. Casserl’ampouledegauche.Agiterlégèrement.L’héroïnen’estpasdéceléeparledéveloppementd’unecouleurquelconqueàcestade.Unecouleurpourpreindiquelaprésenced’Ecstasy(MDMA).

4. Briserl’ampoulededroiteetagiterlégèrement.Levirageimmédiatauvertindiquelaprésenced’héroïne.

Interprétation des couleurs1. Du fait de la présence possible de divers colorants dans certains

types d’héroïne, plusieurs couleurs peuvent apparaître lorsqué lalèreampouleestbrisée.Levirageaupourpreconfirmelaprésenced’Ecstasy.

2. La présence d’héroïne est confirmée avec la 2ème ampoule parl’apparitiond’unecouleurvertequis’intensifieaprèsuneagitationprolongée.Lescouleursindicatricesdel’Ecstasypeuventvarieravecla2èmeampoule.

3. En l’absence de colorants agissantsur le réactif de la premièreampoule,laprésenceéventuelled’héroïnedéceléeparcetestpeutêtreconfirméeparletestA.

MISE EN GARDEA. Étant donné que ces tests contiennent de l’acide fort ou

basique,ilestsuggéréd’utiliserletestF–Neutralisantd’acideaprèslestestsetavantd’endisposer.

B. Avantdedisposerdespochettesdetestutilisées,enlevezl’agrafeetajoutezunemesuredeneutralisantd’acidedutestF.

C. Ajoutezlentementpourempêcherderenverser.D. Nepasrefermerlapochettedetestavantquel’effervescence

nesoitcomplètementterminée.E. Refermezlapochettedetestavecl’agrafeetdisposezdansun

endroitsécuritaireprévuàceteffet.F. N’essayez pas d’écraser les particules de verre une fois les

ampoulescassées.G. Antidote:Encasdecontact,rincezimmédiatementlesyeuxou

lapeauavecdel’eaupendantaumoins15minutesetenlevezvosvêtementsetsoulierscontaminés.Appelezunmédecin.Siavalé,nefaitespasvomir.Siconscient,buvezbeaucoupd’eauafindediluerlaquantitéd’alcool.Appelezunmédecin.

WARNINGCestestsnesontpasfaitspourêtreutilisésavecdeséchantillonsliquides.