SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without...

47
CONTENTS 1.0 TYPICAL VERTICAL JOINT ON RAB 1.1 TYPICAL VERTICAL JOINT ON BUILDING PAPER 2.0 TYPICAL HORIZONTAL JOINT ON RAB 2.1 TYPICAL HORIZONTAL JOINT ON BUILDING PAPER 3.1.0 HEAD DETAIL - FAIRVIEW RESIDENTIAL JOINERY 3.1.1 SILL DETAIL - FAIRVIEW RESIDENTIAL JOINERY 3.1.2 JAMB DETAIL - FAIRVIEW RESIDENTIAL JOINERY 3.2.0 HEAD DETAIL - FAIRVIEW COMMERCIAL JOINERY 3.2.1 SILL DETAIL - FAIRVIEW COMMERCIAL JOINERY 3.2.2 JAMB DETAIL - FAIRVIEW COMMERCIAL JOINERY 3.3.0 HEAD DETAIL - ALTUS RESIDENTIAL JOINERY 3.3.1 SILL DETAIL - ALTUS RESIDENTIAL JOINERY 3.3.2 JAMB DETAIL - ALTUS RESIDENTIAL JOINERY 3.4.0 HEAD DETAIL - ALTUS COMMERCIAL JOINERY 3.4.1 SILL DETAIL - ALTUS COMMERCIAL JOINERY 3.4.2 JAMB DETAIL - ALTUS COMMERCIAL JOINERY 3.5.0 HEAD DETAIL - APL RESIDENTIAL JOINERY 3.5.1 SILL DETAIL - APL RESIDENTIAL JOINERY 3.5.2 JAMB DETAIL - APL RESIDENTIAL JOINERY 3.6.0 HEAD DETAIL - APL COMMERCIAL JOINERY 3.6.1 SILL DETAIL - APL COMMERCIAL JOINERY 3.6.2 JAMB DETAIL - APL COMMERCIAL JOINERY 4.0 FASCIA DETAIL - SOFFIT BY OTHERS AT LOW WIND ZONE 4.1 FASCIA DETAIL - SOFFIT BY OTHERS AT HIGH WIND ZONE 4.2.0 FASCIA TO SOFFIT 4.2.1 FASCIA TO SOFFIT 4.3.0 DRIP EDGE DETAIL 4.3.1 OPEN FLUSH SOFFIT JOINT 5.0 BASE DETAIL 1 5.1 TYPICAL EYEBROW SILL DETAIL 5.2 TYPICAL UPSTAND DETAIL 5.3 INTER-STOREY JOINT 6.0.0 TYPICAL EXTERNAL CORNER 6.0.1 TYPICAL VERTICAL INTERNAL CORNER 6.1 FIBRE CEMENT VERTICAL INTERNAL CORNER 6.2 VERTICAL PROFILED METAL INTERNAL CORNER 6.3 HORIZONTAL PROFILED METAL INTERNAL CORNER 7.0 TYPICAL WALL TO SOFFIT JUNCTION 1 7.1 TYPICAL WALL TO SOFFIT BY JUNCTION 2 7.2.0 TYPICAL WALL TO RAKING SOFFIT JUNCTION 1 7.2.1 TYPICAL WALL TO RAKING SOFFIT JUNCTION 2 7.3 WALL TO SOFFIT JUNCTION & DOWNPIPE PENETRATION 8.0 PRECAST CONCRETE WALL JUNCTION 1 8.1 PRECAST CONCRETE WALL JUNCTION 2 9.0 VERTICAL PROFILED METAL JUNCTION TYPICAL DETAILS SYMONITE TECHNICAL DRAWINGS 2019: ¤ SYMONITE PANELS LIMITED Technical specification subject to change without prior notice SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM 0.0

Transcript of SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without...

Page 1: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

CONTENTS

1.0 TYPICAL VERTICAL JOINT ON RAB

1.1 TYPICAL VERTICAL JOINT ON BUILDING PAPER

2.0 TYPICAL HORIZONTAL JOINT ON RAB

2.1 TYPICAL HORIZONTAL JOINT ON BUILDING PAPER

3.1.0 HEAD DETAIL - FAIRVIEW RESIDENTIAL JOINERY

3.1.1 SILL DETAIL - FAIRVIEW RESIDENTIAL JOINERY

3.1.2 JAMB DETAIL - FAIRVIEW RESIDENTIAL JOINERY

3.2.0 HEAD DETAIL - FAIRVIEW COMMERCIAL JOINERY

3.2.1 SILL DETAIL - FAIRVIEW COMMERCIAL JOINERY

3.2.2 JAMB DETAIL - FAIRVIEW COMMERCIAL JOINERY

3.3.0 HEAD DETAIL - ALTUS RESIDENTIAL JOINERY

3.3.1 SILL DETAIL - ALTUS RESIDENTIAL JOINERY

3.3.2 JAMB DETAIL - ALTUS RESIDENTIAL JOINERY

3.4.0 HEAD DETAIL - ALTUS COMMERCIAL JOINERY

3.4.1 SILL DETAIL - ALTUS COMMERCIAL JOINERY

3.4.2 JAMB DETAIL - ALTUS COMMERCIAL JOINERY

3.5.0 HEAD DETAIL - APL RESIDENTIAL JOINERY

3.5.1 SILL DETAIL - APL RESIDENTIAL JOINERY

3.5.2 JAMB DETAIL - APL RESIDENTIAL JOINERY

3.6.0 HEAD DETAIL - APL COMMERCIAL JOINERY

3.6.1 SILL DETAIL - APL COMMERCIAL JOINERY

3.6.2 JAMB DETAIL - APL COMMERCIAL JOINERY

4.0 FASCIA DETAIL - SOFFIT BY OTHERS AT LOW WIND ZONE

4.1 FASCIA DETAIL - SOFFIT BY OTHERS AT HIGH WIND ZONE

4.2.0 FASCIA TO SOFFIT

4.2.1 FASCIA TO SOFFIT

4.3.0 DRIP EDGE DETAIL

4.3.1 OPEN FLUSH SOFFIT JOINT

5.0 BASE DETAIL 1

5.1 TYPICAL EYEBROW SILL DETAIL

5.2 TYPICAL UPSTAND DETAIL

5.3 INTER-STOREY JOINT

6.0.0 TYPICAL EXTERNAL CORNER

6.0.1 TYPICAL VERTICAL INTERNAL CORNER

6.1 FIBRE CEMENT VERTICAL INTERNAL CORNER

6.2 VERTICAL PROFILED METAL INTERNAL CORNER

6.3 HORIZONTAL PROFILED METAL INTERNAL CORNER

7.0 TYPICAL WALL TO SOFFIT JUNCTION 1

7.1 TYPICAL WALL TO SOFFIT BY JUNCTION 2

7.2.0 TYPICAL WALL TO RAKING SOFFIT JUNCTION 1

7.2.1 TYPICAL WALL TO RAKING SOFFIT JUNCTION 2

7.3 WALL TO SOFFIT JUNCTION & DOWNPIPE PENETRATION

8.0 PRECAST CONCRETE WALL JUNCTION 1

8.1 PRECAST CONCRETE WALL JUNCTION 2

9.0 VERTICAL PROFILED METAL JUNCTION

TYPICAL DETAILS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

0.0

Page 2: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

General notes:

1. Consider 'hatched' areas as outside of Symonite scope and indicative only.

2. All commercial detailing shows rigid air barrier (RAB) as is common practice.

3. All residential detailing shows building wrap as is common practice.

Framing note: Timber framing by others is to be at 600 centres max for both studs &

nogs. This may be required at closer centers subject to engineering requirements.

Rigid air barrier note: As per Symonite BRANZ Appraisal #528 section 12.2 "A

building with exposure to wind on any part of its facade above 1.55 kPa ULS must

use a RAB as backing for the cavity". It is the building designers responsibility to

determine wind loading on the building and incorporate RAB into the detailing as

required to the specifications of the RAB manufacturer.

Cavity Battens are not required with the Symonite cladding system as a cavity is

formed between the fixing angles and structure with high impact plastic packers ("H"

packers). Minimum cavity depth is 40mm from structure to outer face of panel

although experience shows the cavity is normally 50mm or more. Any instance

where cavity is pushed beyond 60mm may require the installation of 20mm cavity

battens by others.

NOTES

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

0.1

Page 3: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

1.0

NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600

CTRS MAX FOR BOTH STUDS & NOGS. MAY BE

REQUIRED AT CLOSER CENTERS SUBJECT TO

ENGINEERING REQUIREMENTS

1

-

1:2 @ A4

TYPICAL VERTICAL JOINT ON RAB (PLAN)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

20

50

-7

0

VA

RIE

S

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

SPECIFIED RAB BOARD ON

TIMBER FRAMING

BY OTHERS

ALI. FIXING EXTRUSIONS

BY SYMONITE

15

SEALANT ON PEF ROD

BY SYMONITE

Page 4: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

1

-1:2 @ A4

TYPICAL VERTICAL JOINT ON BUILDING PAPER (PLAN)

20

50

-7

0

VA

RIE

S

ALI. FIXING EXTRUSIONS

BY SYMONITE

SEALANT ON PEF ROD

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

90mm WIDE 0.9mm

ALI. UNDERTRAY

BY SYMONITE

15

BUILDING PAPER ON

TIMBER FRAMING

BY OTHERS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

1.1

NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600

CTRS MAX FOR BOTH STUDS & NOGS. MAY BE

REQUIRED AT CLOSER CENTERS SUBJECT TO

ENGINEERING REQUIREMENTS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

Page 5: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

1

-1:2 @ A4

TYPICAL HORIZONTAL JOINT ON RAB (SECTION)

50-70

VARIES

SEALANT ON PEF ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED WHEN

MORE THAN 2 PACKERS ARE

USED)

ALI. FIXING EXTRUSIONS

BY SYMONITE

15

20

SPECIFIED RAB BOARD ON

TIMBER FRAMING

BY OTHERS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

2.0

NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600

CTRS MAX FOR BOTH STUDS & NOGS. MAY BE

REQUIRED AT CLOSER CENTERS SUBJECT TO

ENGINEERING REQUIREMENTS

Page 6: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

2.1

NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600

CTRS MAX FOR BOTH STUDS & NOGS. MAY BE

REQUIRED AT CLOSER CENTERS SUBJECT TO

ENGINEERING REQUIREMENTS

1

- 1:2 @ A4

TYPICAL HORIZONTAL JOINT ON BUILDING PAPER (SECTION DETAIL)

50-70

VARIES

SEALANT ON PEF ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED WHEN

MORE THAN 2 PACKERS ARE USED)

ALI. FIXING EXTRUSIONS

BY SYMONITE

15

20

ALI. UNDERTRAY

BY SYMONITE

BUILDING PAPER ON

TIMBER FRAMING

BY OTHERS

Page 7: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

HEAD DETAIL - FAIRVIEW RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.1.0

PACKING BY SYMONITE

OR STRAPPING BY OTHERS

MAY BE REQUIRED

DEPENDING ON JOINERY

PROFILE

ALUCOBOND PLUS OR

ALUCOBOND A2 BY

SYMONITE

HEAD FLASHING AND

FLASHING TAPE

BY OTHERS

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

40X40X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

BREATHABLE

BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR

SEAL BY OTHERS

UNDERTRAY AT

JOINT

BY SYMONITE

PROPRIETARY

JOINERY

BY FAIRVIEW

12

20

MIN.

15

MIN. PANEL

OVERLAP TO

JOINERY

50-70

VARIES

Page 8: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SILL DETAIL - FAIRVIEW RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

2

JOINERY SEALED

TO PANEL

BY SYMONITE

UNDERTRAY

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

PACKING BY SYMONITE

OR STRAPPING BY

OTHERS MAY BE

REQUIRED DEPENDING

ON JOINERY PROFILE

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.1.1

12

15

5 MIN. VENTILATION GAP

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

10°

PROPRIETARY JOINERY

BY FAIRVIEW

Page 9: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

JAMB DETAIL - FAIRVIEW RESIDENTIAL JOINERY (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.1.2

20

MIN

.

15

15

MIN.

50

-7

0

VA

RIE

S

TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

PROPRIETARY JOINERY

BY FAIRVIEW

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 10: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.2.0

1

-

1:2 @ A4

TYPICAL FAIRVIEW COMMERCIAL HEAD DETAIL (SECTION)

12

20

MIN.

50-70

VARIES

15

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

BUILDING PAPER LAPPED

OVER HEAD FLASHING

BY OTHERS

HEAD FLASHING

BY JOINERY COMPANY

40X25X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

PROPRIETARY

JOINERY BY

FAIRVIEW

MIN. PANEL

OVERLAP TO

JOINERY

Page 11: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

2

-

1:2 @ A4

TYPICAL FAIRVIEW COMMERCIAL SILL DETAIL (SECTION)

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.2.1

12

15

5 MIN. VENTILATION GAP

JOINERY SEALED

TO PANEL

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SOAKERS AT PANEL JOINTS

BY SYMONITE

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

10°

PROPRIETARY

JOINERY BY FAIRVIEW

Page 12: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.2.2

1

-

1:2 @ A4

TYPICAL FAIRVIEW COMMERCIAL JAMB DETAIL (PLAN)

15

20

M

IN

.

15

MIN.

COVER

50

-7

0

VA

RIE

S

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

15MM MIN.

PANEL COVER

TO JOINERY

SPECIFIED RAB BOARD OR BUILDING

PAPER ON TIMBER FRAMING

BY OTHERS

FIXING

BRACKETS TO

ENGINEERING

SPECIFICATIONS

BY SYMONITE

PROPRIETARY

JOINERY

BY FAIRVIEW

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 13: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

HEAD DETAIL - ALTUS RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.3.0

PACKING BY SYMONITE

OR STRAPPING BY OTHERS

MAY BE REQUIRED

DEPENDING ON JOINERY

PROFILE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

HEAD FLASHING AND

FLASHING TAPE

BY OTHERS

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

40X40X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

BREATHABLE

BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR

SEAL BY OTHERS

UNDERTRAY AT

JOINT

BY SYMONITE

PROPRIETARY

JOINERY

BY ALTUS

12

20

MIN.

15

MIN. PANEL

OVERLAP TO

JOINERY

50-70

VARIES

Page 14: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SILL DETAIL - ALTUS RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

2

JOINERY SEALED

TO PANEL

BY SYMONITE

UNDERTRAY

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

PACKING BY SYMONITE

OR STRAPPING BY

OTHERS MAY BE

REQUIRED DEPENDING

ON JOINERY PROFILE

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.3.1

12

15

5 MIN. VENTILATION GAP

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

10°

PROPRIETARY JOINERY

BY ALTUS

Page 15: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

JAMB DETAIL - ALTUS RESIDENTIAL JOINERY (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.3.2

20

MIN

.

15

15

MIN.

50

-7

0

VA

RIE

S

TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

PROPRIETARY JOINERY

BY ALTUS

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 16: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.4.0

1

-

1:2 @ A4

TYPICAL ALTUS COMMERCIAL HEAD DETAIL (SECTION)

12

20

MIN.

50-70

VARIES

15

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

BUILDING PAPER LAPPED

OVER HEAD FLASHING

BY OTHERS

HEAD FLASHING

BY JOINERY COMPANY

40X25X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

PROPRIETARY

JOINERY BY ALTUS

MIN. PANEL

OVERLAP TO

JOINERY

Page 17: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

2

-

1:2 @ A4

TYPICAL ALTUS COMMERCIAL SILL DETAIL (SECTION)

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.4.1

12

15

5 MIN. VENTILATION GAP

JOINERY SEALED

TO PANEL

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SOAKERS AT PANEL JOINTS

BY SYMONITE

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

10°

PROPRIETARY

JOINERY BY ALTUS

Page 18: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.4.2

1

-

1:2 @ A4

TYPICAL ALTUS COMMERCIAL JAMB DETAIL (PLAN)

15

20

M

IN

.

16

MIN.

COVER

50

-7

0

VA

RIE

S

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

15MM MIN.

PANEL COVER

TO JOINERY

SPECIFIED RAB BOARD OR BUILDING

PAPER ON TIMBER FRAMING

BY OTHERS

FIXING

BRACKETS TO

ENGINEERING

SPECIFICATIONS

BY SYMONITE

PROPRIETARY JOINERY

BY ALTUS

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 19: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

HEAD DETAIL - APL RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.5.0

PACKING BY SYMONITE

OR STRAPPING BY OTHERS

MAY BE REQUIRED

DEPENDING ON JOINERY

PROFILE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

HEAD FLASHING AND

FLASHING TAPE

BY OTHERS

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

40X40X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

BREATHABLE

BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR

SEAL BY OTHERS

UNDERTRAY AT

JOINT

BY SYMONITE

PROPRIETARY

JOINERY

BY APL

12

20

MIN.

15MIN. PANEL

OVERLAP TO

JOINERY

50-70

VARIES

Page 20: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SILL DETAIL - APL RESIDENTIAL JOINERY (SECTION)

1:2 @ A4-

2

JOINERY SEALED

TO PANEL

BY SYMONITE

UNDERTRAY

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

PACKING BY SYMONITE

OR STRAPPING BY

OTHERS MAY BE

REQUIRED DEPENDING

ON JOINERY PROFILE

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.5.1

12

15

5 MIN. VENTILATION GAP

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

PROPRIETARY JOINERY

BY APL

10°

Page 21: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

JAMB DETAIL - APL RESIDENTIAL JOINERY (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.5.2

20

MIN

.

15

15

MIN.

50

-7

0

VA

RIE

S

TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

PROPRIETARY JOINERY

BY APL

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

BREATHABLE BUILDING

PAPER ON TIMBER

FRAMING

BY OTHERS

FLASHING TAPE,

PACKING & AIR SEAL

BY OTHERS

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 22: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.6.0

1

-

1:2 @ A4

TYPICAL APL COMMERCIAL HEAD DETAIL (SECTION)

12

20

MIN.

50-70

VARIES

15

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

BUILDING PAPER LAPPED

OVER HEAD FLASHING

BY OTHERS

HEAD FLASHING

BY JOINERY COMPANY

40X25X1.6mm CONTINUOUS

ALI. FIXING ANGLE OR

SIMILAR BY SYMONITE

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

PROPRIETARY

JOINERY BY APL

MIN. PANEL

OVERLAP TO

JOINERY

Page 23: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

2

-

1:2 @ A4

TYPICAL APL COMMERCIAL SILL DETAIL (SECTION)

IMPORTANT: ENSURE 15MM MIN

CLEARANCE FROM INSIDE OF SILL TRAY

TO FLASHING TAPE, FOR PANEL UPSTAND

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.6.1

12

15

5 MIN. VENTILATION GAP

JOINERY SEALED

TO PANEL

BY SYMONITE

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

SOAKERS AT PANEL JOINTS

BY SYMONITE

SPECIFIED RAB BOARD OR

BUILDING PAPER ON TIMBER

FRAMING BY OTHERS

0.9mm ALI. BACKFOLD

SUPPORT

BY SYMONITE

10°

PROPRIETARY

JOINERY BY APL

Page 24: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

3.4.2

1

-

1:2 @ A4

TYPICAL APL COMMERCIAL JAMB DETAIL (PLAN)

15

20

M

IN

.

16

MIN.

COVER

50

-7

0

VA

RIE

S

PACKING, AIR SEAL&

FLEX. FLASHING TAPE

ALL BY OTHERS

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

15MM MIN.

PANEL COVER

TO JOINERY

SPECIFIED RAB BOARD OR BUILDING

PAPER ON TIMBER FRAMING

BY OTHERS

FIXING

BRACKETS TO

ENGINEERING

SPECIFICATIONS

BY SYMONITE

PROPRIETARY JOINERY

BY APL

LINE OF HEAD

FLASHING ABOVE

BY OTHERS

Page 25: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

10-15

75

M

IN

. C

OV

ER

35

M

IN

.

CL

EA

R

50-70

VARIES

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

UNDERFLASHING

AT JOINTS

BY SYMONITE

VENT SLOTS OR

HOLES TO ALLOW

A MINIMUM

1000mm

2

/lm

BY SYMONITE

MEMBRANE

ON PLY BY

OTHERS

ROOF FRAMING

BY OTHERS

SOFFIT

BY OTHERS

ALI. FIXING

ANGLE &

SEALANT ON PEF

ROD

BY SYMONITE

FASCIA DETAIL - SOFFIT BY OTHERS AT LOW WIND ZONE (SECTION)

1:2 @ A4

-

1

50

M

IN

.

VA

RIE

S1

5

50

-7

0

VA

RIE

S

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.0

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

MIN

.

VENT SLOTS OR

HOLES TO

ALLOW A

MINIMUM

1000mm

2

/lm

BY SYMONITE

VARIES

Page 26: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

75

M

IN

. C

OV

ER

35

M

IN

.

CL

EA

R

50-70

VARIES

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

UNDERFLASHING

AT JOINTS

BY SYMONITE

VENT SLOTS OR

HOLES TO ALLOW

A MINIMUM

1000mm

2

/lm

BY SYMONITE

MEMBRANE

ON PLY BY

OTHERS

ROOF FRAMING

BY OTHERS

SOFFIT

BY OTHERS

ALI. FIXING

ANGLE &

SEALANT ON PEF

ROD

BY SYMONITE

FASCIA DETAIL - SOFFIT BY OTHERS AT HIGH WIND ZONE (SECTION)

1:2 @ A4

-

1

50

M

IN

.

VA

RIE

S1

5

50

-7

0

VA

RIE

S

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.1

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

MIN

.

VENT SLOTS OR

HOLES TO

ALLOW A

MINIMUM

1000mm

2

/lm

BY SYMONITE

Page 27: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.2.0

ACM FASCIA TO SOFFIT 1 (SECTION)

1:2 @ A4

-

1

VENT SLOTS OR

HOLES TO ALLOW A

MINIMUM 1000mm

2

/lm

BY SYMONITE

50

-7

0

VA

RIE

S

15

FACTORY FITTED

CLEATS AT PANEL FOLDS

BY SYMONITE

AS REQUIRED

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

50-70

VARIES

Page 28: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

ACM FASCIA TO SOFFIT 2 (SECTION)

1:2 @ A4

-

2

VENT SLOTS OR

HOLES TO ALLOW A

MINIMUM 1000mm

2

/lm

BY SYMONITE

ALI. FIXING ANGLE &

SEALANT ON PEF ROD

BY SYMONITE

50

-7

0

VA

RIE

S

15

FACTORY FITTED

CLEATS AT PANEL FOLDS

BY SYMONITE

AS REQUIRED

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

50-70

VARIES

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.2.1

Page 29: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.3.0

DRIP EDGE DETAIL (SECTION)

1:2 @ A4

-

1

VENT SLOTS OR

HOLES TO ALLOW A

MINIMUM 1000mm

2

/lm

BY SYMONITE

AL FIXING ANGLE,

FIXING EXTRUSION &

SEALANT ON PEF ROD

BY SYMONITE

FACTORY FITTED

CLEATS AT PANEL FOLDS

BY SYMONITE

AS REQUIRED

10

50

NO

M.

60

NO

M.

50

NOM.

30

DRIP EDGE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

Page 30: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

OPEN FLUSH SOFFIT JOINT (SECTION)

1:2 @ A4

-

1

VENT SLOTS OR

HOLES TO ALLOW A

MINIMUM 1000mm

2

/lm

BY SYMONITE

FACTORY FITTED

CLEATS AT PANEL FOLDS

BY SYMONITE

AS REQUIRED

CONTINUOUS BLACK

POWDERCOATED ALI. EXTRUSION

WITH VISIBLE SS FIXINGS @ 600

CRS BY SYMONITE

SOFFIT WITH EDGE TRIM ANGLE

ALL BY OTHERS

50

NOM.

15

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

4.3.1

Page 31: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

BASE DETAIL 1 (SECTION)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

5.0

55-70

VARIES

50

M

IN

.

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

VENT SLOTS OR HOLES

TO ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

CONCRETE SLAB

BY OTHERS

ADJACENT GROUND

SCREW FIXING BY SYMONITE

RIVET FIXING

BY SYMONITE

ALI. FIXING EXTRUSION

BY SYMONITE

ALI. CUSTOM EXTRUSION

BY SYMONITE

-

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

SEALANT

BY SYMONITE

A - 100mm For Exterior Paving

B - 175mm For Unpaved Ground

C - 50mm For Garage Floor

Page 32: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

12

15

15

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

5.1

1

-

1:5 @ A4

TYPICAL EYEBROW SILL DETAIL (SECTION)

50

NO

M.

40

NO

M.

15

30

0 M

IN

T

O A

DJA

CE

NT

G

RO

UN

D

FO

R F

IX

IN

G A

CC

ES

S

FACTORY FITTED CLEATS

AT PANEL FOLDS

BY SYMONITE

UNDERFLASHING @

PANEL JOINTS

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED WHEN

MORE THAN 2 PACKERS ARE

USED)

SPECIFIED RAB BOARD

OR BUILDING PAPER

OVER TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

PRECAST CONCRETE BY OTHERS

ADJACENT

GROUND

ALI. FIXING EXTRUSION

BY SYMONITE

HIGH IMPACT PLASTIC

PACKERS BEYOND AT

ACM PANEL JOINTS

BY SYMOINTE

12

SELECTED MEMBRANE

BY OTHERS

15

15

15

20

MIN. 10° FALL

15MM MIN CLEARANCE AT SILL

TRAY FOR PANEL UPSTAND

60MM MIN CLEARANCE

FROM BOTTOM OF SILL

TRAY LEG TO FRAMING

BELOW

JOINERY, PACKING,

AIR SEAL ALL BY

OTHERS

0.9MM ALI. BACKFOLD

SUPPORT BY SYMONITE

PANEL SEALED TO

SILL TRAY BY

SYMONITE

5-8MM MIN VENTILATION GAP

Page 33: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

5.2

1

-

1:2 @ A4

TYPICAL UPSTAND DETAIL (SECTION)

50

NOM.

50

NOM.

15

MIN. 10°

SELECTED MEMBRANE

OVER PLY / TIMBER FRAMING

ALL BY OTHERS

FACTORY FITTED

CLEATS AT PANEL

FOLDS BY SYMONITE

UNDERFLASHING

@ PANEL JOINTS

BY SYMONITE

AL. FIXING EXTRUSION

& SEALANT ON PEF ROD

BY SYMONITE

0.9mm ALI.

BACKFOLD SUPPORT

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

5

0

N

O

M

.

Page 34: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

5.3

INTER-STOREY JOINT (SECTION)

1:2 @ A4

-

1

55

NOM.

20

11

10°

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

35

40

U

PS

TA

ND

SEALANT

BY SYMONITE

SCREW FIXING

BY SYMONITE

ALI. CUSTOM EXTRUSION

BY SYMONITE

ALI. FIXING EXTRUSION

BY SYMONITE

VENT SLOTS OR HOLES TO

ALLOW A MINIMUM

1000mm

2

/lm

BY SYMONITE

MOVEMENT ZONE

Page 35: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

6.0.0

1

-

1:2 @ A4

TYPICAL EXTERNAL CORNER (PLAN)

50-70

VARIES

50

-7

0

VA

RIE

S

CLEATS AT PANEL FOLDS

(FACTORY FITTED WHEN

INSTALLATION

CONSTRAINTS ALLOW)

BY SYMONITE

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED WHEN

MORE THAN 2 PACKERS ARE

USED)

SPECIFIED RAB BOARD OR BUILDING

PAPER ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

Page 36: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

TYPICAL VERTICAL INTERNAL CORNER (PLAN)

1:2 @ A4-

1

50-70

VARIES

15

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED WHEN

MORE THAN 2 PACKERS ARE USED)

ALI. FIXING ANGLE, FIXING EXTRUSION,

& SEALANT ON BACKING ROD

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

6.0.1

Page 37: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

50-70

VARIES

ALI. FIXING EXTRUSION, &

SEALANT ON BACKING ROD

BY SYMONITE

15

FIBRE CEMENT SHEET

BY OTHERS

INTERNAL CORNER

BACK FLASHING

BY OTHERS

FIBRE CEMENT VERTICAL INTERNAL CORNER (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

6.1

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

Page 38: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

15

ALI. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

VERTICAL PROFILED

METAL CLADDING

BY OTHERS

FLASHING

BY OTHERS

50

-7

0

VA

RIE

S

VERTICAL PROFILED METAL INTERNAL CORNER (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

6.2

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

Page 39: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

50-70

VARIES

ALI. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE

15

HORIZONTAL PROFILED

METAL CLADDING

BY OTHERS

COMPRESSIBLE FOAM SEAL

BY OTHERS

CORNER FLASHING

BY OTHERS

HORIZONTAL PROFILED METAL INTERNAL CORNER (PLAN)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

6.3

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

PACKING OR FIXING ANGLE

BY SYMONITE

Page 40: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

50-70

VARIES

15

SOFFIT LINING

BY OTHERS

TYPICAL WALL TO SOFFIT JUNCTION 1 (SECTION)

1:2 @ A4

-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

7.0

AL. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

PACKING OR FIXING ANGLE

BY SYMONITE

Page 41: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

50-70

VARIES

SOFFIT LINING

BY OTHERS

TYPICAL WALL TO SOFFIT JUNCTION 2 (SECTION)

1:2 @ A4-

1

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

7.1

PACKING OR FIXING

BRACKET IN LUGS

BY SYMONITE

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

WB LUGS

BY SYMONITE

SUGGESTED

BACK

FLASHING

BY OTHERS

P/C RAINSCREEN

FLASHING

BY OTHERS

Page 42: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

50-70

VARIES

FLASHING

BY OTHERS

FIXING EXTRUSION

BY SYMONITE

WALL TO RAKING SOFFIT JUNCTION 1 (SECTION)

1:2 @ A4

-

1

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

7.2.0

75

C

OV

ER

.

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

FULL WEATHER EXPOSURE

SOFFIT LINING INSTALLED

AFTER ALUCOBOND PLUS

OR ALUCOBOND A2

BY OTHERS

Page 43: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

50-70

VARIES

WALL TO RAKING SOFFIT JUNCTION 2 (SECTION)

1:2 @ A4

-

1

15

AS

RE

Q.

SOFFIT LINING INSTALLED

BEFORE ALUCOBOND PLUS

OR ALUCOBOND A2

BY OTHERS

ALI. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

FLASHING

BY OTHERS

INTERIOR OR LOW

WEATHER EXPOSURE

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

7.2.1

Page 44: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

7.3

WALL TO SOFFIT JUNCTION & DOWNPIPE PENETRATION (SECTION)

1:2 @ A4

-

1

50-70

VARIES

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

DOWNPIPE OR

OVERFLOW

BY OTHERS

AL. FIXING EXTRUSION &

SEALANT ON PEF ROD

BY SYMONITE

PENETRATION TO BE

CUT AROUND ON SITE

AND COVER SEALED

BY SYMONITE

SOFFIT FRAMING

TO BE AT 450mm

CRS MAX BY

OTHERS

50

-7

0

VA

RIE

S

SPECIFIED RAB BOARD OR BUILDING

PAPER ON TIMBER FRAMING

BY OTHERS

Page 45: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

15

38

V

AR

IE

S

PRECAST CONCRETE WALL JUNCTION 1 (PLAN)

1:2 @ A4

-

1

ALI. FIXING ANGLE &

SEALANT ON BACKING ROD

BY SYMONITE

PRE CAST

CONCRETE WALL

BY OTHERS

TIMBER FRAMING

BY OTHERS

HIGH IMPACT PACKERS

BY SYMONITE

(INDEPENDENTLY FIXED

WHEN MORE THAN 2

PACKERS ARE USED)

50

-7

0

VA

RIE

S

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

8.0

SCREW FIXING WITH

NYLON PLUGS

BY SYMONITE

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

P/C FIXING ANGLE TO

ENGINEER'S SPECIFICATIONS

BY SYMONITE

Page 46: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

15

ALI. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE

BACK FLASHING SEALED TO

SAWCUT CHASE

BY OTHERS

(RECOMMENDED)

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

PRECAST CONCRETE WALL JUNCTION 2 (PLAN)

1:2 @ A4

-

1

50

-7

0

VA

RIE

S

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

8.1

PRE CAST

CONCRETE WALL

BY OTHERS

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

NOTE: CHASED FLASHING IS RECOMMENDED AT ALL

VERTICAL CONCRETE JUNCTION DETAILS. IT IS THE

BUILDING DESIGNER'S RESPONSIBILITY TO CHECK

WITH APPLICABLE LOCAL BUILDING AUTHORITIES AS

TO WHETHER THIS IS REQUIRED

Page 47: SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without prior notice symonite alucobond plus or a2 cladding system 3.2.0 1 - 1:2 @ a4 typical

15

TIMBER FRAMING

BY OTHERS

COLORSTEEL FLASHING

BY OTHERS, PRIOR

TO INSTALLATION OF ACM

COLOUR STEEL CLADDING

ALL BY OTHERS

ALUCOBOND PLUS OR

ALUCOBOND A2

BY SYMONITE

VERTICAL PROFILED METAL JUNCTION (PLAN)

1:2 @ A4

-

1

50-70

VARIES

SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED

Technical specification subject to change without prior notice

SYMONITE ALUCOBOND PLUS OR A2

CLADDING SYSTEM

9.0

SPECIFIED RAB BOARD

OR BUILDING PAPER

ON TIMBER FRAMING

BY OTHERS

ALI. FIXING EXTRUSION &

SEALANT ON BACKING ROD

BY SYMONITE