SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without...
Transcript of SYMONITE ALUCOBOND PLUS OR A2 CLADDING SYSTEM · technical specification subject to change without...
CONTENTS
1.0 TYPICAL VERTICAL JOINT ON RAB
1.1 TYPICAL VERTICAL JOINT ON BUILDING PAPER
2.0 TYPICAL HORIZONTAL JOINT ON RAB
2.1 TYPICAL HORIZONTAL JOINT ON BUILDING PAPER
3.1.0 HEAD DETAIL - FAIRVIEW RESIDENTIAL JOINERY
3.1.1 SILL DETAIL - FAIRVIEW RESIDENTIAL JOINERY
3.1.2 JAMB DETAIL - FAIRVIEW RESIDENTIAL JOINERY
3.2.0 HEAD DETAIL - FAIRVIEW COMMERCIAL JOINERY
3.2.1 SILL DETAIL - FAIRVIEW COMMERCIAL JOINERY
3.2.2 JAMB DETAIL - FAIRVIEW COMMERCIAL JOINERY
3.3.0 HEAD DETAIL - ALTUS RESIDENTIAL JOINERY
3.3.1 SILL DETAIL - ALTUS RESIDENTIAL JOINERY
3.3.2 JAMB DETAIL - ALTUS RESIDENTIAL JOINERY
3.4.0 HEAD DETAIL - ALTUS COMMERCIAL JOINERY
3.4.1 SILL DETAIL - ALTUS COMMERCIAL JOINERY
3.4.2 JAMB DETAIL - ALTUS COMMERCIAL JOINERY
3.5.0 HEAD DETAIL - APL RESIDENTIAL JOINERY
3.5.1 SILL DETAIL - APL RESIDENTIAL JOINERY
3.5.2 JAMB DETAIL - APL RESIDENTIAL JOINERY
3.6.0 HEAD DETAIL - APL COMMERCIAL JOINERY
3.6.1 SILL DETAIL - APL COMMERCIAL JOINERY
3.6.2 JAMB DETAIL - APL COMMERCIAL JOINERY
4.0 FASCIA DETAIL - SOFFIT BY OTHERS AT LOW WIND ZONE
4.1 FASCIA DETAIL - SOFFIT BY OTHERS AT HIGH WIND ZONE
4.2.0 FASCIA TO SOFFIT
4.2.1 FASCIA TO SOFFIT
4.3.0 DRIP EDGE DETAIL
4.3.1 OPEN FLUSH SOFFIT JOINT
5.0 BASE DETAIL 1
5.1 TYPICAL EYEBROW SILL DETAIL
5.2 TYPICAL UPSTAND DETAIL
5.3 INTER-STOREY JOINT
6.0.0 TYPICAL EXTERNAL CORNER
6.0.1 TYPICAL VERTICAL INTERNAL CORNER
6.1 FIBRE CEMENT VERTICAL INTERNAL CORNER
6.2 VERTICAL PROFILED METAL INTERNAL CORNER
6.3 HORIZONTAL PROFILED METAL INTERNAL CORNER
7.0 TYPICAL WALL TO SOFFIT JUNCTION 1
7.1 TYPICAL WALL TO SOFFIT BY JUNCTION 2
7.2.0 TYPICAL WALL TO RAKING SOFFIT JUNCTION 1
7.2.1 TYPICAL WALL TO RAKING SOFFIT JUNCTION 2
7.3 WALL TO SOFFIT JUNCTION & DOWNPIPE PENETRATION
8.0 PRECAST CONCRETE WALL JUNCTION 1
8.1 PRECAST CONCRETE WALL JUNCTION 2
9.0 VERTICAL PROFILED METAL JUNCTION
TYPICAL DETAILS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
0.0
General notes:
1. Consider 'hatched' areas as outside of Symonite scope and indicative only.
2. All commercial detailing shows rigid air barrier (RAB) as is common practice.
3. All residential detailing shows building wrap as is common practice.
Framing note: Timber framing by others is to be at 600 centres max for both studs &
nogs. This may be required at closer centers subject to engineering requirements.
Rigid air barrier note: As per Symonite BRANZ Appraisal #528 section 12.2 "A
building with exposure to wind on any part of its facade above 1.55 kPa ULS must
use a RAB as backing for the cavity". It is the building designers responsibility to
determine wind loading on the building and incorporate RAB into the detailing as
required to the specifications of the RAB manufacturer.
Cavity Battens are not required with the Symonite cladding system as a cavity is
formed between the fixing angles and structure with high impact plastic packers ("H"
packers). Minimum cavity depth is 40mm from structure to outer face of panel
although experience shows the cavity is normally 50mm or more. Any instance
where cavity is pushed beyond 60mm may require the installation of 20mm cavity
battens by others.
NOTES
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
0.1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
1.0
NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600
CTRS MAX FOR BOTH STUDS & NOGS. MAY BE
REQUIRED AT CLOSER CENTERS SUBJECT TO
ENGINEERING REQUIREMENTS
1
-
1:2 @ A4
TYPICAL VERTICAL JOINT ON RAB (PLAN)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
20
50
-7
0
VA
RIE
S
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
SPECIFIED RAB BOARD ON
TIMBER FRAMING
BY OTHERS
ALI. FIXING EXTRUSIONS
BY SYMONITE
15
SEALANT ON PEF ROD
BY SYMONITE
1
-1:2 @ A4
TYPICAL VERTICAL JOINT ON BUILDING PAPER (PLAN)
20
50
-7
0
VA
RIE
S
ALI. FIXING EXTRUSIONS
BY SYMONITE
SEALANT ON PEF ROD
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
90mm WIDE 0.9mm
ALI. UNDERTRAY
BY SYMONITE
15
BUILDING PAPER ON
TIMBER FRAMING
BY OTHERS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
1.1
NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600
CTRS MAX FOR BOTH STUDS & NOGS. MAY BE
REQUIRED AT CLOSER CENTERS SUBJECT TO
ENGINEERING REQUIREMENTS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
1
-1:2 @ A4
TYPICAL HORIZONTAL JOINT ON RAB (SECTION)
50-70
VARIES
SEALANT ON PEF ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED WHEN
MORE THAN 2 PACKERS ARE
USED)
ALI. FIXING EXTRUSIONS
BY SYMONITE
15
20
SPECIFIED RAB BOARD ON
TIMBER FRAMING
BY OTHERS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
2.0
NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600
CTRS MAX FOR BOTH STUDS & NOGS. MAY BE
REQUIRED AT CLOSER CENTERS SUBJECT TO
ENGINEERING REQUIREMENTS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
2.1
NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600
CTRS MAX FOR BOTH STUDS & NOGS. MAY BE
REQUIRED AT CLOSER CENTERS SUBJECT TO
ENGINEERING REQUIREMENTS
1
- 1:2 @ A4
TYPICAL HORIZONTAL JOINT ON BUILDING PAPER (SECTION DETAIL)
50-70
VARIES
SEALANT ON PEF ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED WHEN
MORE THAN 2 PACKERS ARE USED)
ALI. FIXING EXTRUSIONS
BY SYMONITE
15
20
ALI. UNDERTRAY
BY SYMONITE
BUILDING PAPER ON
TIMBER FRAMING
BY OTHERS
HEAD DETAIL - FAIRVIEW RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.1.0
PACKING BY SYMONITE
OR STRAPPING BY OTHERS
MAY BE REQUIRED
DEPENDING ON JOINERY
PROFILE
ALUCOBOND PLUS OR
ALUCOBOND A2 BY
SYMONITE
HEAD FLASHING AND
FLASHING TAPE
BY OTHERS
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
40X40X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
BREATHABLE
BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR
SEAL BY OTHERS
UNDERTRAY AT
JOINT
BY SYMONITE
PROPRIETARY
JOINERY
BY FAIRVIEW
12
20
MIN.
15
MIN. PANEL
OVERLAP TO
JOINERY
50-70
VARIES
SILL DETAIL - FAIRVIEW RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
2
JOINERY SEALED
TO PANEL
BY SYMONITE
UNDERTRAY
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
PACKING BY SYMONITE
OR STRAPPING BY
OTHERS MAY BE
REQUIRED DEPENDING
ON JOINERY PROFILE
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.1.1
12
15
5 MIN. VENTILATION GAP
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
10°
PROPRIETARY JOINERY
BY FAIRVIEW
JAMB DETAIL - FAIRVIEW RESIDENTIAL JOINERY (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.1.2
20
MIN
.
15
15
MIN.
50
-7
0
VA
RIE
S
TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
PROPRIETARY JOINERY
BY FAIRVIEW
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.2.0
1
-
1:2 @ A4
TYPICAL FAIRVIEW COMMERCIAL HEAD DETAIL (SECTION)
12
20
MIN.
50-70
VARIES
15
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
BUILDING PAPER LAPPED
OVER HEAD FLASHING
BY OTHERS
HEAD FLASHING
BY JOINERY COMPANY
40X25X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
PROPRIETARY
JOINERY BY
FAIRVIEW
MIN. PANEL
OVERLAP TO
JOINERY
2
-
1:2 @ A4
TYPICAL FAIRVIEW COMMERCIAL SILL DETAIL (SECTION)
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.2.1
12
15
5 MIN. VENTILATION GAP
JOINERY SEALED
TO PANEL
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SOAKERS AT PANEL JOINTS
BY SYMONITE
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
10°
PROPRIETARY
JOINERY BY FAIRVIEW
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.2.2
1
-
1:2 @ A4
TYPICAL FAIRVIEW COMMERCIAL JAMB DETAIL (PLAN)
15
20
M
IN
.
15
MIN.
COVER
50
-7
0
VA
RIE
S
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
15MM MIN.
PANEL COVER
TO JOINERY
SPECIFIED RAB BOARD OR BUILDING
PAPER ON TIMBER FRAMING
BY OTHERS
FIXING
BRACKETS TO
ENGINEERING
SPECIFICATIONS
BY SYMONITE
PROPRIETARY
JOINERY
BY FAIRVIEW
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
HEAD DETAIL - ALTUS RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.3.0
PACKING BY SYMONITE
OR STRAPPING BY OTHERS
MAY BE REQUIRED
DEPENDING ON JOINERY
PROFILE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
HEAD FLASHING AND
FLASHING TAPE
BY OTHERS
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
40X40X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
BREATHABLE
BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR
SEAL BY OTHERS
UNDERTRAY AT
JOINT
BY SYMONITE
PROPRIETARY
JOINERY
BY ALTUS
12
20
MIN.
15
MIN. PANEL
OVERLAP TO
JOINERY
50-70
VARIES
SILL DETAIL - ALTUS RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
2
JOINERY SEALED
TO PANEL
BY SYMONITE
UNDERTRAY
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
PACKING BY SYMONITE
OR STRAPPING BY
OTHERS MAY BE
REQUIRED DEPENDING
ON JOINERY PROFILE
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.3.1
12
15
5 MIN. VENTILATION GAP
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
10°
PROPRIETARY JOINERY
BY ALTUS
JAMB DETAIL - ALTUS RESIDENTIAL JOINERY (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.3.2
20
MIN
.
15
15
MIN.
50
-7
0
VA
RIE
S
TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
PROPRIETARY JOINERY
BY ALTUS
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.4.0
1
-
1:2 @ A4
TYPICAL ALTUS COMMERCIAL HEAD DETAIL (SECTION)
12
20
MIN.
50-70
VARIES
15
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
BUILDING PAPER LAPPED
OVER HEAD FLASHING
BY OTHERS
HEAD FLASHING
BY JOINERY COMPANY
40X25X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
PROPRIETARY
JOINERY BY ALTUS
MIN. PANEL
OVERLAP TO
JOINERY
2
-
1:2 @ A4
TYPICAL ALTUS COMMERCIAL SILL DETAIL (SECTION)
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.4.1
12
15
5 MIN. VENTILATION GAP
JOINERY SEALED
TO PANEL
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SOAKERS AT PANEL JOINTS
BY SYMONITE
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
10°
PROPRIETARY
JOINERY BY ALTUS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.4.2
1
-
1:2 @ A4
TYPICAL ALTUS COMMERCIAL JAMB DETAIL (PLAN)
15
20
M
IN
.
16
MIN.
COVER
50
-7
0
VA
RIE
S
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
15MM MIN.
PANEL COVER
TO JOINERY
SPECIFIED RAB BOARD OR BUILDING
PAPER ON TIMBER FRAMING
BY OTHERS
FIXING
BRACKETS TO
ENGINEERING
SPECIFICATIONS
BY SYMONITE
PROPRIETARY JOINERY
BY ALTUS
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
HEAD DETAIL - APL RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.5.0
PACKING BY SYMONITE
OR STRAPPING BY OTHERS
MAY BE REQUIRED
DEPENDING ON JOINERY
PROFILE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
HEAD FLASHING AND
FLASHING TAPE
BY OTHERS
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
40X40X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
BREATHABLE
BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR
SEAL BY OTHERS
UNDERTRAY AT
JOINT
BY SYMONITE
PROPRIETARY
JOINERY
BY APL
12
20
MIN.
15MIN. PANEL
OVERLAP TO
JOINERY
50-70
VARIES
SILL DETAIL - APL RESIDENTIAL JOINERY (SECTION)
1:2 @ A4-
2
JOINERY SEALED
TO PANEL
BY SYMONITE
UNDERTRAY
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
PACKING BY SYMONITE
OR STRAPPING BY
OTHERS MAY BE
REQUIRED DEPENDING
ON JOINERY PROFILE
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.5.1
12
15
5 MIN. VENTILATION GAP
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
PROPRIETARY JOINERY
BY APL
10°
JAMB DETAIL - APL RESIDENTIAL JOINERY (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.5.2
20
MIN
.
15
15
MIN.
50
-7
0
VA
RIE
S
TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
PROPRIETARY JOINERY
BY APL
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
BREATHABLE BUILDING
PAPER ON TIMBER
FRAMING
BY OTHERS
FLASHING TAPE,
PACKING & AIR SEAL
BY OTHERS
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.6.0
1
-
1:2 @ A4
TYPICAL APL COMMERCIAL HEAD DETAIL (SECTION)
12
20
MIN.
50-70
VARIES
15
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
BUILDING PAPER LAPPED
OVER HEAD FLASHING
BY OTHERS
HEAD FLASHING
BY JOINERY COMPANY
40X25X1.6mm CONTINUOUS
ALI. FIXING ANGLE OR
SIMILAR BY SYMONITE
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
PROPRIETARY
JOINERY BY APL
MIN. PANEL
OVERLAP TO
JOINERY
2
-
1:2 @ A4
TYPICAL APL COMMERCIAL SILL DETAIL (SECTION)
IMPORTANT: ENSURE 15MM MIN
CLEARANCE FROM INSIDE OF SILL TRAY
TO FLASHING TAPE, FOR PANEL UPSTAND
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.6.1
12
15
5 MIN. VENTILATION GAP
JOINERY SEALED
TO PANEL
BY SYMONITE
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
SOAKERS AT PANEL JOINTS
BY SYMONITE
SPECIFIED RAB BOARD OR
BUILDING PAPER ON TIMBER
FRAMING BY OTHERS
0.9mm ALI. BACKFOLD
SUPPORT
BY SYMONITE
10°
PROPRIETARY
JOINERY BY APL
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
3.4.2
1
-
1:2 @ A4
TYPICAL APL COMMERCIAL JAMB DETAIL (PLAN)
15
20
M
IN
.
16
MIN.
COVER
50
-7
0
VA
RIE
S
PACKING, AIR SEAL&
FLEX. FLASHING TAPE
ALL BY OTHERS
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
15MM MIN.
PANEL COVER
TO JOINERY
SPECIFIED RAB BOARD OR BUILDING
PAPER ON TIMBER FRAMING
BY OTHERS
FIXING
BRACKETS TO
ENGINEERING
SPECIFICATIONS
BY SYMONITE
PROPRIETARY JOINERY
BY APL
LINE OF HEAD
FLASHING ABOVE
BY OTHERS
10-15
75
M
IN
. C
OV
ER
35
M
IN
.
CL
EA
R
50-70
VARIES
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
UNDERFLASHING
AT JOINTS
BY SYMONITE
VENT SLOTS OR
HOLES TO ALLOW
A MINIMUM
1000mm
2
/lm
BY SYMONITE
MEMBRANE
ON PLY BY
OTHERS
ROOF FRAMING
BY OTHERS
SOFFIT
BY OTHERS
ALI. FIXING
ANGLE &
SEALANT ON PEF
ROD
BY SYMONITE
FASCIA DETAIL - SOFFIT BY OTHERS AT LOW WIND ZONE (SECTION)
1:2 @ A4
-
1
50
M
IN
.
VA
RIE
S1
5
50
-7
0
VA
RIE
S
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.0
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
5°
MIN
.
VENT SLOTS OR
HOLES TO
ALLOW A
MINIMUM
1000mm
2
/lm
BY SYMONITE
VARIES
75
M
IN
. C
OV
ER
35
M
IN
.
CL
EA
R
50-70
VARIES
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
UNDERFLASHING
AT JOINTS
BY SYMONITE
VENT SLOTS OR
HOLES TO ALLOW
A MINIMUM
1000mm
2
/lm
BY SYMONITE
MEMBRANE
ON PLY BY
OTHERS
ROOF FRAMING
BY OTHERS
SOFFIT
BY OTHERS
ALI. FIXING
ANGLE &
SEALANT ON PEF
ROD
BY SYMONITE
FASCIA DETAIL - SOFFIT BY OTHERS AT HIGH WIND ZONE (SECTION)
1:2 @ A4
-
1
50
M
IN
.
VA
RIE
S1
5
50
-7
0
VA
RIE
S
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.1
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
5°
MIN
.
VENT SLOTS OR
HOLES TO
ALLOW A
MINIMUM
1000mm
2
/lm
BY SYMONITE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.2.0
ACM FASCIA TO SOFFIT 1 (SECTION)
1:2 @ A4
-
1
VENT SLOTS OR
HOLES TO ALLOW A
MINIMUM 1000mm
2
/lm
BY SYMONITE
50
-7
0
VA
RIE
S
15
FACTORY FITTED
CLEATS AT PANEL FOLDS
BY SYMONITE
AS REQUIRED
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
50-70
VARIES
ACM FASCIA TO SOFFIT 2 (SECTION)
1:2 @ A4
-
2
VENT SLOTS OR
HOLES TO ALLOW A
MINIMUM 1000mm
2
/lm
BY SYMONITE
ALI. FIXING ANGLE &
SEALANT ON PEF ROD
BY SYMONITE
50
-7
0
VA
RIE
S
15
FACTORY FITTED
CLEATS AT PANEL FOLDS
BY SYMONITE
AS REQUIRED
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
50-70
VARIES
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.2.1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.3.0
DRIP EDGE DETAIL (SECTION)
1:2 @ A4
-
1
VENT SLOTS OR
HOLES TO ALLOW A
MINIMUM 1000mm
2
/lm
BY SYMONITE
AL FIXING ANGLE,
FIXING EXTRUSION &
SEALANT ON PEF ROD
BY SYMONITE
FACTORY FITTED
CLEATS AT PANEL FOLDS
BY SYMONITE
AS REQUIRED
10
50
NO
M.
60
NO
M.
50
NOM.
30
DRIP EDGE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
OPEN FLUSH SOFFIT JOINT (SECTION)
1:2 @ A4
-
1
VENT SLOTS OR
HOLES TO ALLOW A
MINIMUM 1000mm
2
/lm
BY SYMONITE
FACTORY FITTED
CLEATS AT PANEL FOLDS
BY SYMONITE
AS REQUIRED
CONTINUOUS BLACK
POWDERCOATED ALI. EXTRUSION
WITH VISIBLE SS FIXINGS @ 600
CRS BY SYMONITE
SOFFIT WITH EDGE TRIM ANGLE
ALL BY OTHERS
50
NOM.
15
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
4.3.1
BASE DETAIL 1 (SECTION)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
5.0
55-70
VARIES
50
M
IN
.
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
VENT SLOTS OR HOLES
TO ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
CONCRETE SLAB
BY OTHERS
ADJACENT GROUND
SCREW FIXING BY SYMONITE
RIVET FIXING
BY SYMONITE
ALI. FIXING EXTRUSION
BY SYMONITE
ALI. CUSTOM EXTRUSION
BY SYMONITE
-
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
SEALANT
BY SYMONITE
A - 100mm For Exterior Paving
B - 175mm For Unpaved Ground
C - 50mm For Garage Floor
12
15
15
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
5.1
1
-
1:5 @ A4
TYPICAL EYEBROW SILL DETAIL (SECTION)
50
NO
M.
40
NO
M.
15
30
0 M
IN
T
O A
DJA
CE
NT
G
RO
UN
D
FO
R F
IX
IN
G A
CC
ES
S
FACTORY FITTED CLEATS
AT PANEL FOLDS
BY SYMONITE
UNDERFLASHING @
PANEL JOINTS
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED WHEN
MORE THAN 2 PACKERS ARE
USED)
SPECIFIED RAB BOARD
OR BUILDING PAPER
OVER TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
PRECAST CONCRETE BY OTHERS
ADJACENT
GROUND
ALI. FIXING EXTRUSION
BY SYMONITE
HIGH IMPACT PLASTIC
PACKERS BEYOND AT
ACM PANEL JOINTS
BY SYMOINTE
12
SELECTED MEMBRANE
BY OTHERS
15
15
15
20
MIN. 10° FALL
15MM MIN CLEARANCE AT SILL
TRAY FOR PANEL UPSTAND
60MM MIN CLEARANCE
FROM BOTTOM OF SILL
TRAY LEG TO FRAMING
BELOW
JOINERY, PACKING,
AIR SEAL ALL BY
OTHERS
0.9MM ALI. BACKFOLD
SUPPORT BY SYMONITE
PANEL SEALED TO
SILL TRAY BY
SYMONITE
5-8MM MIN VENTILATION GAP
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
5.2
1
-
1:2 @ A4
TYPICAL UPSTAND DETAIL (SECTION)
50
NOM.
50
NOM.
15
MIN. 10°
SELECTED MEMBRANE
OVER PLY / TIMBER FRAMING
ALL BY OTHERS
FACTORY FITTED
CLEATS AT PANEL
FOLDS BY SYMONITE
UNDERFLASHING
@ PANEL JOINTS
BY SYMONITE
AL. FIXING EXTRUSION
& SEALANT ON PEF ROD
BY SYMONITE
0.9mm ALI.
BACKFOLD SUPPORT
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
5
0
N
O
M
.
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
5.3
INTER-STOREY JOINT (SECTION)
1:2 @ A4
-
1
55
NOM.
20
11
10°
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
35
40
U
PS
TA
ND
SEALANT
BY SYMONITE
SCREW FIXING
BY SYMONITE
ALI. CUSTOM EXTRUSION
BY SYMONITE
ALI. FIXING EXTRUSION
BY SYMONITE
VENT SLOTS OR HOLES TO
ALLOW A MINIMUM
1000mm
2
/lm
BY SYMONITE
MOVEMENT ZONE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
6.0.0
1
-
1:2 @ A4
TYPICAL EXTERNAL CORNER (PLAN)
50-70
VARIES
50
-7
0
VA
RIE
S
CLEATS AT PANEL FOLDS
(FACTORY FITTED WHEN
INSTALLATION
CONSTRAINTS ALLOW)
BY SYMONITE
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED WHEN
MORE THAN 2 PACKERS ARE
USED)
SPECIFIED RAB BOARD OR BUILDING
PAPER ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
TYPICAL VERTICAL INTERNAL CORNER (PLAN)
1:2 @ A4-
1
50-70
VARIES
15
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED WHEN
MORE THAN 2 PACKERS ARE USED)
ALI. FIXING ANGLE, FIXING EXTRUSION,
& SEALANT ON BACKING ROD
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
6.0.1
50-70
VARIES
ALI. FIXING EXTRUSION, &
SEALANT ON BACKING ROD
BY SYMONITE
15
FIBRE CEMENT SHEET
BY OTHERS
INTERNAL CORNER
BACK FLASHING
BY OTHERS
FIBRE CEMENT VERTICAL INTERNAL CORNER (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
6.1
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
15
ALI. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
VERTICAL PROFILED
METAL CLADDING
BY OTHERS
FLASHING
BY OTHERS
50
-7
0
VA
RIE
S
VERTICAL PROFILED METAL INTERNAL CORNER (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
6.2
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
50-70
VARIES
ALI. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE
15
HORIZONTAL PROFILED
METAL CLADDING
BY OTHERS
COMPRESSIBLE FOAM SEAL
BY OTHERS
CORNER FLASHING
BY OTHERS
HORIZONTAL PROFILED METAL INTERNAL CORNER (PLAN)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
6.3
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
PACKING OR FIXING ANGLE
BY SYMONITE
50-70
VARIES
15
SOFFIT LINING
BY OTHERS
TYPICAL WALL TO SOFFIT JUNCTION 1 (SECTION)
1:2 @ A4
-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
7.0
AL. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
PACKING OR FIXING ANGLE
BY SYMONITE
50-70
VARIES
SOFFIT LINING
BY OTHERS
TYPICAL WALL TO SOFFIT JUNCTION 2 (SECTION)
1:2 @ A4-
1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
7.1
PACKING OR FIXING
BRACKET IN LUGS
BY SYMONITE
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
WB LUGS
BY SYMONITE
SUGGESTED
BACK
FLASHING
BY OTHERS
P/C RAINSCREEN
FLASHING
BY OTHERS
50-70
VARIES
FLASHING
BY OTHERS
FIXING EXTRUSION
BY SYMONITE
WALL TO RAKING SOFFIT JUNCTION 1 (SECTION)
1:2 @ A4
-
1
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
7.2.0
75
C
OV
ER
.
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
FULL WEATHER EXPOSURE
SOFFIT LINING INSTALLED
AFTER ALUCOBOND PLUS
OR ALUCOBOND A2
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
50-70
VARIES
WALL TO RAKING SOFFIT JUNCTION 2 (SECTION)
1:2 @ A4
-
1
15
AS
RE
Q.
SOFFIT LINING INSTALLED
BEFORE ALUCOBOND PLUS
OR ALUCOBOND A2
BY OTHERS
ALI. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
FLASHING
BY OTHERS
INTERIOR OR LOW
WEATHER EXPOSURE
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
7.2.1
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
7.3
WALL TO SOFFIT JUNCTION & DOWNPIPE PENETRATION (SECTION)
1:2 @ A4
-
1
50-70
VARIES
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
DOWNPIPE OR
OVERFLOW
BY OTHERS
AL. FIXING EXTRUSION &
SEALANT ON PEF ROD
BY SYMONITE
PENETRATION TO BE
CUT AROUND ON SITE
AND COVER SEALED
BY SYMONITE
SOFFIT FRAMING
TO BE AT 450mm
CRS MAX BY
OTHERS
50
-7
0
VA
RIE
S
SPECIFIED RAB BOARD OR BUILDING
PAPER ON TIMBER FRAMING
BY OTHERS
15
38
V
AR
IE
S
PRECAST CONCRETE WALL JUNCTION 1 (PLAN)
1:2 @ A4
-
1
ALI. FIXING ANGLE &
SEALANT ON BACKING ROD
BY SYMONITE
PRE CAST
CONCRETE WALL
BY OTHERS
TIMBER FRAMING
BY OTHERS
HIGH IMPACT PACKERS
BY SYMONITE
(INDEPENDENTLY FIXED
WHEN MORE THAN 2
PACKERS ARE USED)
50
-7
0
VA
RIE
S
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
8.0
SCREW FIXING WITH
NYLON PLUGS
BY SYMONITE
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
P/C FIXING ANGLE TO
ENGINEER'S SPECIFICATIONS
BY SYMONITE
15
ALI. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE
BACK FLASHING SEALED TO
SAWCUT CHASE
BY OTHERS
(RECOMMENDED)
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
PRECAST CONCRETE WALL JUNCTION 2 (PLAN)
1:2 @ A4
-
1
50
-7
0
VA
RIE
S
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
8.1
PRE CAST
CONCRETE WALL
BY OTHERS
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
NOTE: CHASED FLASHING IS RECOMMENDED AT ALL
VERTICAL CONCRETE JUNCTION DETAILS. IT IS THE
BUILDING DESIGNER'S RESPONSIBILITY TO CHECK
WITH APPLICABLE LOCAL BUILDING AUTHORITIES AS
TO WHETHER THIS IS REQUIRED
15
TIMBER FRAMING
BY OTHERS
COLORSTEEL FLASHING
BY OTHERS, PRIOR
TO INSTALLATION OF ACM
COLOUR STEEL CLADDING
ALL BY OTHERS
ALUCOBOND PLUS OR
ALUCOBOND A2
BY SYMONITE
VERTICAL PROFILED METAL JUNCTION (PLAN)
1:2 @ A4
-
1
50-70
VARIES
SYMONITE TECHNICAL DRAWINGS 2019: SYMONITE PANELS LIMITED
Technical specification subject to change without prior notice
SYMONITE ALUCOBOND PLUS OR A2
CLADDING SYSTEM
9.0
SPECIFIED RAB BOARD
OR BUILDING PAPER
ON TIMBER FRAMING
BY OTHERS
ALI. FIXING EXTRUSION &
SEALANT ON BACKING ROD
BY SYMONITE