Introduction to Morishima
・ Refresh・ Development of Plate Changer・ Development of Dry lens scanning ・ Development of SUTS system
Status
Optical
Magnitude
Speed
(100cm2 area scan)
(cm2/hour)
Data taking from the dateafter moves to TONO
SUTS01 50 20 2008-Oct-31
SUTS02 35 50 2008-Aug-06
SUTS03 35 50 2008-Jul-08
SUTS04 35 50 2009-Jan-17
SUTS05 35 50 2008-Jul-17
All stages are constructed and tuned by Nakano and Morishima
Performance
Optical
Magnitude
Speed
(100cm2 area scan)
(cm2/hour)
MicroTrack Angle resolution
mrad (Tanθ<0.1)
X Y
SUTS01 50 20 14+-1 8+-1
SUTS02 35 50 13+-1 10+-1
SUTS03 35 50 13+-1 10+-1
SUTS04 35 50 13+-1 10+-1
SUTS05 35 50 12+-1 11+-1All stages are constructed and tuned by Nakano and Morishima
Running
90 % of SUTS machine time used for CS scanning10 % of ECC volume scan using 1 SUTS (normally SUTS02 or 03)
4 SUTS (01/02/03/05) 9.8 CS/day → 68.6 CS/week5 SUTS 12.6 CS/day → 88.2 CS/week
SUTS Scanning Shift
SUTS Running Speed
Stream of scanning and processing : CS
change plates
MakingMicroTracks
MakingBaseTracks
ComptonAlignment
Onlinescanningmonitor
Optimize the parameter of scanning and the flow of the processing
Check qualities of all eventsand Judge whether to do manual-check or re-scanning
3/4 connection
4/4 connection
selection
Online process : CS
Morishima
Manual checklist
Check monitor
When the trouble occures, call to Morishima
→ automation
Onlineprocessing
monitor
shifter
CS
Improvement of scanning qualities
Side view of the surface recognized by suts
GOOD BAD
Bad Ratio : ~ 10 %
Now : ~ 2 %
Training and carefully setting
1. Condition of scanning parameter is changed (set the lowest threshold to secure base track efficiency more than 93% (now, only CS, not yet ECC) )
2 . Plate setting
Result in these effects will be presented by next talker T.Fukuda
100micron
Air enters under film,and it is floating
ECC dataTracking efficiency distribution of some bricks
efficiency
Solution・ Slow speed scanning ・ Two or more recognition boards are used for one SUTS (one present)
Background component is different from CS.Not fog but compton tracks are the main.
Summery
5 SUTS are running CS scanning speed ~ 88 CS/week Improving the qualities by changing the parameter setting and the plate setting.
In near future, CS data quality check will be automated as soon as possible, and built in the shift task.
I make efforts to the improvement of the data taking and processing of ECC for Vertex Confirmation and Decay Search Analysis.