Supplementary Online Materials for Neural Origin of Spontaneous Hemodynamic Fluctuations in Rats...
-
Upload
candace-potter -
Category
Documents
-
view
222 -
download
2
Transcript of Supplementary Online Materials for Neural Origin of Spontaneous Hemodynamic Fluctuations in Rats...
Supplementary Online Materials for
Neural Origin of Spontaneous Hemodynamic Fluctuations in Rats under Burst-Suppression
Anesthesia Condition
Xiao Liu,1,2 Xiao-Hong Zhu,1 Yi Zhang,1 and Wei Chen1,2,*
1Center for Magnetic Resonance ResearchDepartment of Radiology, 2Department of
Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
*To whom correspondence should be addressedEmail: [email protected]
Figure Captions (Supplementary)
Figure S1 Appearance frequency of the EEG bursts as a function of isoflurane anesthesia level. The error bars stand for the standard errors across measurement runs. Figure S2 Reproducibility and reliability of the individual fMRI experimental results. The BOLD correlation maps generated based on fourteen fMRI runs from a representative rat (Rat 9) show a consistent pattern under the same condition across multiple runs, and distinct patterns between different conditions (A). For each individual, the correlation strength (between a ROI in the left S1FL and the right S1FL reference region, see Materials and Methods in the manuscript for details) was plotted as a function of anesthesia level (B). All animals show a very similar trend, and the averaged inter-subject result and statistics have been presented in the manuscript (Figure 6E).
Figure S3 Reproducibility of the BOLD correlation maps. The original correlation maps from a representative rat (Rat 9) are compared with those generated based on three reorganized datasets. The comparison datasets were created by temporally under-sampling the original datasets (keeping one time point every three), only using the first half of total time points (240 image volumes), and only using the second half of total time points, respectively. All correlation maps demonstrate similar trends across different conditions with only the original ones show a relatively higher correlation power due to favorable time averaging.
0
2
4
6
8
10
12
ISO 1.8 ISO 2.0 ISO 2.2
EE
G B
urs
t F
req
ue
nc
y (
min
-1)
Anesthesia Level
Figure S1
Dea
d
ISO
2.2
ISO
2.0
ISO
1.8
Run 1 Run 2 Run 3 Run 4 Run 1 Run 2 Run 3 Run 4
Run 1 Run 2 Run 3 Run 4 Run 1 Run 2
Co
rrel
atio
n (r)
1.0
-1.0
-0.5
0.5
A
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
ISO 1.8 ISO 2.0 ISO 2.2 DEAD
Rat 1Rat 2Rat 3Rat 4Rat 5Rat 6Rat 7Rat 8Rat 9Rat 10
B
Co
rrel
atio
n C
oe
ffic
ien
ts (r)
Reliability
Reproducibility
Figure S2
Original data Lower Temporal Resolution
First Half of Data Second Half of Data
Correlation Coefficient (r)1.0-1.0 -0.3 0.3
ISO 1.8 ISO 2.0 ISO 2.2 Dead
Figure S3